1.
J Appl Clin Med Phys ; 20(2): 94-106, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30672648

RESUMEN

Despite the improvements in the dose calculation models of the commercial treatment planning systems (TPS), their ability to accurately predict patient dose is still limited. One of the limitations is caused by the simplified model of the multileaf collimator (MLC). The aim of this study was to develop a Monte Carlo (MC) method-based independent patient dose validation system with an elaborate MLC model for more accurate dose evaluation. Varian Clinac 2300 IX was simulated using Geant4 toolkits, after which MC commissioning with measurements was performed to validate the simulation model. A DICOM-RT interface was developed to obtain the beam delivery conditions including the hundreds of MLC motions. Finally, the TPS dose distributions were compared with the MC dose distributions for water phantom cases and a patient case. Our results show that the TPS overestimated the absolute abutting leakage dose in the closed MLC field, with about 20% more of the maximum dose than that of the MC calculation. For water phantom cases, the dose distributions inside the target region were almost identical with the dose difference of less than 2%, while the dose near the edge of the target shows difference about 10% between Geant4 and TPS due to geometrical differences in MLC model. For the patient analysis, the Geant4 and TPS doses of all organs were matched well within 1.4% of the prescribed dose. However, for organs located in areas with high ratio of leaf pairs with distances less than 10 mm leaf pair (LP(<10mm) ), the maximum dose of TPS was overestimated by about 3% of the prescribed dose. These dose comparison results demonstrate that our system for calculating the patient dose is quite accurate. Furthermore, if the MLC sequences in treatment plan have a large ratio of LP(short) , more than 3% dose difference in normal tissue could be seen.


Asunto(s)
Simulación por Computador , Método de Montecarlo , Neoplasias/radioterapia , Fantasmas de Imagen , Radiometría/instrumentación , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Algoritmos , Humanos , Órganos en Riesgo/efectos de la radiación , Radiometría/métodos , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/instrumentación
2.
Phys Med ; 51: 117-124, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29914795

RESUMEN

Leksell GammaPlan was specifically designed for Gamma Knife (GK) radiosurgery planning, but it has limited accuracy for estimating the dose distribution in inhomogeneous areas, such as the embolization of arteriovenous malformations. We aimed to develop an independent patient dose validation system based on a patient-specific model, constructed using a DICOM-RT interface and the Geant4 toolkit. Leksell Gamma Knife Perfexion was designed in Geant4.10.00 and includes a DICOM-RT interface. Output factors for each collimator in a sector and dose distributions in a spherical water phantom calculated using a Monte Carlo (MC) algorithm were compared with the output factors calculated by the tissue maximum ratio (TMR) 10 algorithm and dose distributions measured using film, respectively. Studies using two types of water phantom and two patient simulation cases were evaluated by comparing the dose distributions calculated by the MC, the TMR and the convolution algorithms. The water phantom studies showed that if the beam size is small and the target is located in heterogeneous media, the dose difference could be up to 11%. In the two patient simulations, the TMR algorithm overestimated the dose by about 4% of the maximum dose if a complex and large bony structure was located on the beam path, whereas the convolution algorithm showed similar results to those of the MC algorithm. This study demonstrated that the in-house system could accurately verify the patient dose based on full MC simulation and so would be useful for patient cases where the dose differences are suspected.


Asunto(s)
Método de Montecarlo , Dosis de Radiación , Radiocirugia/instrumentación , Fantasmas de Imagen , Dosificación Radioterapéutica