Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
BMC Infect Dis ; 20(1): 320, 2020 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-32366227

RESUMEN

BACKGROUND: Rapid diagnostic tests (RDTs) are a cornerstone of HIV diagnosis and rely on good quality processing and interpretation, particularly in the era of test and treat. The Deki Reader (Fio Corporation®, Toronto, Ontario, Canada) is a portable device designed specifically for analysing RDTs and was selected for evaluation in South Africa in the context of HIV RDT analysis. METHODS: This study consisted of a laboratory evaluation and two-part field evaluation of the Deki Reader v100, covering two RDT testing algorithms, and an evaluation of the continuous quality monitoring through the Fionet™ web portal. Based on user feedback from the field evaluation, the device underwent hardware and software redesign, and the Deki Reader v200 was evaluated in the laboratory. Ethics approval for this evaluation was obtained from the University of the Witwatersrand Human Research Ethics Committee: M150160. RESULTS: The intra- and inter-device laboratory precision of the Deki Reader v100 were 98.3 and 99.2% respectively, and 99.3 and 100% for the Deki Reader v200. The laboratory concordances compared to standard-of-care reporting were 99.5 and 98.0% for the two respective models, while sensitivity and specificity were 99.5 and 99.4% for the Deki Reader V100 and 100 and 93.1% for the Deki Reader V200 respectively. Screening and confirmatory concordances in the field were 99.3 and 96.5% under algorithm 1 and 99.7 and 100% under algorithm 2. Sensitivity and specificity for the field evaluation were 99.8 and 97.7%. Overall robustness of the device was acceptable and continuous quality monitoring through Fionet™ was feasible. CONCLUSIONS: The Deki Reader provides an option for improved and reliable quality assessment for rapid diagnosis of HIV using RDTs to enhance the quality of healthcare at the point-of-care. However, the introduction of new RDTs and modification of current algorithms necessitates ongoing and agile RDT reader adjustments, which will require cost modelling to ensure sustainability of devices implemented into national HIV programs.


Asunto(s)
Serodiagnóstico del SIDA/instrumentación , Pruebas Diagnósticas de Rutina/instrumentación , Ensayo de Inmunoadsorción Enzimática/instrumentación , Infecciones por VIH/diagnóstico , Infecciones por VIH/epidemiología , VIH-1/inmunología , VIH-2/inmunología , Serodiagnóstico del SIDA/métodos , Algoritmos , Pruebas Diagnósticas de Rutina/métodos , Ensayo de Inmunoadsorción Enzimática/métodos , Infecciones por VIH/virología , Humanos , Tamizaje Masivo/métodos , Aplicaciones Móviles , Sistemas de Atención de Punto , Prevalencia , Sensibilidad y Especificidad , Sudáfrica/epidemiología
2.
Malar J ; 17(1): 214, 2018 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-29843721

RESUMEN

BACKGROUND: Although microscopy is a standard diagnostic tool for malaria and the gold standard, it is infrequently used because of unavailability of laboratory facilities and the absence of skilled readers in poor resource settings. Malaria rapid diagnostic tests (RDT) are currently used instead of or as an adjunct to microscopy. However, at very low parasitaemia (usually < 100 asexual parasites/µl), the test line on malaria rapid diagnostic tests can be faint and consequently hard to visualize and this may potentially affect the interpretation of the test results. Fio Corporation (Canada), developed an automated RDT reader named Deki Reader™ for automatic analysis and interpretation of rapid diagnostic tests. This study aimed to compare visual assessment and automated Deki Reader evaluations to interpret malaria rapid diagnostic tests against microscopy. Unlike in the previous studies where expert laboratory technicians interpreted the test results visually and operated the device, in this study low cadre health care workers who have not attended any formal professional training in laboratory sciences were employed. METHODS: Finger prick blood from 1293 outpatients with fever was tested for malaria using RDT and Giemsa-stained microscopy for thick and thin blood smears. Blood samples for RDTs were processed according to manufacturers' instructions automated in the Deki Reader. Results of malaria diagnoses were compared between visual and the automated devise reading of RDT and microscopy. RESULTS: The sensitivity of malaria rapid diagnostic test results interpreted by the Deki Reader was 94.1% and that of visual interpretation was 93.9%. The specificity of malaria rapid diagnostic test results was 71.8% and that of human interpretation was 72.0%. The positive predictive value of malaria RDT results by the Deki Reader and visual interpretation was 75.8 and 75.4%, respectively, while the negative predictive values were 92.8 and 92.4%, respectively. The accuracy of RDT as interpreted by DR and visually was 82.6 and 82.1%, respectively. CONCLUSION: There was no significant difference in performance of RDTs interpreted by either automated DR or visually by unskilled health workers. However, despite the similarities in performance parameters, the device has proven useful because it provides stepwise guidance on processing RDT, data transfer and reporting.


Asunto(s)
Pruebas Diagnósticas de Rutina/métodos , Malaria/diagnóstico , Microscopía/métodos , Pacientes Ambulatorios/estadística & datos numéricos , Parasitemia/diagnóstico , Adolescente , Adulto , Femenino , Instituciones de Salud , Humanos , Masculino , Instalaciones Militares , Sensibilidad y Especificidad , Tanzanía , Adulto Joven
3.
Malar J ; 16(1): 449, 2017 11 07.
Artículo en Inglés | MEDLINE | ID: mdl-29115991

RESUMEN

BACKGROUND: Early diagnosis of suspected malaria cases with a rapid diagnostic test (RDT) has been shown to be an effective malaria control tool used in many resource-constrained settings. However, poor quality control and quality assurance hinder the accurate reporting of malaria diagnoses. Recent use of a portable, battery operated RDT reader (Deki Reader™, Fio Corporation) has shown to have high agreement with visual inspection across diverse health centre settings, however evidence of its feasibility and usability during cross sectional surveys are limited. This study aimed to evaluate the performance of the Deki Reader™ in a cross-sectional survey of children from southwestern Uganda. METHODS: A two-stage, stratified cluster sampling survey was conducted between July and October 2014 in three districts of southwestern Uganda, with varying malaria transmission intensities. A total of 566 children aged 6-59 months were included in the analysis. Blood samples were collected and tested for malaria using: the SD Bioline Malaria Ag Pf/Pan RDT and microscopy. Results were compared between visual inspection of the RDT and by the Deki Reader™. Diagnostic performance of both methods were compared to gold-standard microscopy. RESULTS: The sensitivity and specificity of the Deki Reader™ was 94.1% (95% CI 69.2-99.6%) and 95.6% (95% CI 93.4-97.1%), respectively. The overall percent agreement between the Deki Reader™ and visual RDT inspection was 98.9% (95% CI 93.2-99.8), with kappa statistic of 0.92 (95% CI 0.85-0.98). CONCLUSIONS: The findings from this study suggest that the Deki Reader™ is comparable to visual inspection and performs well in detecting microscopy-positive Plasmodium falciparum cases in a household survey setting. However, the reader's performance was highly dependent on ensuring adequate battery life and a work environment free of dirt particles.


Asunto(s)
Pruebas Diagnósticas de Rutina/instrumentación , Pruebas Diagnósticas de Rutina/métodos , Malaria/diagnóstico , Preescolar , Estudios Transversales , Diagnóstico Precoz , Procesamiento Automatizado de Datos , Monitoreo Epidemiológico , Femenino , Humanos , Lactante , Malaria/epidemiología , Masculino , Sensibilidad y Especificidad , Uganda/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA