Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Environ Res ; 241: 117560, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-37949290

RESUMEN

The properties of biocarriers significantly influence the performance of a moving bed-biofilm reactor (MBBR). This study aimed to assess the impact of media type, filling ratio, and hydraulic retention time (HRT) on biofilm formation and MBBR performance in both batch and continuous setups using real municipal wastewater. Two different media, high-density polyethylene (HDPE) and polypropylene (PPE), with varying surface area and properties were used. Biofilm growth and MBBR performance were monitored and optimized using response surface methodology. The effect of different media was investigated for three filling ratios of 20%, 40% and 60% and HRT of 4, 6 and 8 h. Results depicted a better biofilm growth on HDPE media in comparison to PPE carriers due to difference in media structure and surface properties. At all the conditions tested, HDPE media showed comparatively better performance for the removal of organic matter and nutrients than PPE media. The maximum organic matter removal efficiency was found as 77% and 75% at an HRT of 6 h and filling ratio of 40% for HDPE and PPE media, respectively. The ammonia removal was also found better for HDPE media due to its geometry and structure favoring the anoxic conditions with maximum removal of 89% achieved at 6-h HRT and 40% filling ratio. Overall, the system with HDPE media indicated more stability in terms of reactor performance than PPE carriers with variations in the operating conditions.


Asunto(s)
Eliminación de Residuos Líquidos , Aguas Residuales , Eliminación de Residuos Líquidos/métodos , Biopelículas , Polietileno , Reactores Biológicos
2.
J Shoulder Elbow Surg ; 33(5): 1075-1083, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37777044

RESUMEN

BACKGROUND: The design of humeral implants has evolved from the initial Grammont design, notably regarding the neck-shaft angle (NSA) and through the use of cementless prostheses. Stress shielding was frequently reported with cementless implants, the 2 main risk factors being humeral stem misalignment and high filling ratios. Our hypothesis was that standard length cementless stems with an NSA of 140° would facilitate good alignment with moderate filling ratios, thereby limiting stress shielding and ensuring good clinical outcomes. METHODS: A single-center retrospective study was conducted of patients who underwent reverse total shoulder arthroplasty between January 2015 and August 2017, with at least 2 years' follow-up. Clinical evaluations included range of motion measurements and Constant and subjective shoulder values scores. Frontal alignment was assessed in terms of the angle (α) between axes of the stem and of the humerus. Filling ratios were measured in the metaphysis of the humerus, in the diaphysis, and at the distal end of the stem and considered excessive above 0.7. Stress shielding was evidenced radiographically by the observation of medial cortical narrowing, medial metaphysis thinning, lateral metaphysis thinning or under-the-baseplate osteolysis. RESULTS: Eighty-two shoulders were included and 70 had radiographic follow-up data available. The mean patient age was 78 years and 63/81 patients (78%) were female. The mean follow-up time was 39 ± 7 months. The mean α angle was 1.4° ± 0.9° and was less than 5° in all cases. The mean metaphyseal, diaphyseal, and distal filling ratios were 0.61 ± 0.06, 0.70 ± 0.08, and 0.64 ± 0.09, respectively. The mean Constant score improved from 28 ± 11 preoperatively to 64 ± 14 at last follow-up. The mean subjective shoulder values score at last follow-up was 81 ± 12. Seventy-nine percent of patients (55/70) had at least 1 form of stress-shielding related, which were not associated with clinical outcomes, apart from lateral metaphysis thinning, which was associated with lower active anterior elevation (mean, 106° ± 30° vs. 126° ± 28°; P = .01) and lower Constant scores (mean, 56 ± 17 vs. 65 ± 14; P = .06). CONCLUSION: The use of cementless reverse shoulder prostheses with a NSA of 140° was associated with good clinical outcomes at 2 years' follow-up. The prosthesis stem was correctly aligned with the humeral axis and the filling ratios were <0.7 in all cases. Stress-shielding was common but, apart from lateral metaphysis thinning, this had no impact on clinical outcomes.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Articulación del Hombro , Prótesis de Hombro , Humanos , Femenino , Anciano , Masculino , Artroplastía de Reemplazo de Hombro/efectos adversos , Estudios Retrospectivos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Estudios de Seguimiento , Resultado del Tratamiento , Diseño de Prótesis , Prótesis de Hombro/efectos adversos , Húmero/diagnóstico por imagen , Húmero/cirugía , Rango del Movimiento Articular
3.
Arch Orthop Trauma Surg ; 144(2): 663-672, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38010377

RESUMEN

INTRODUCTION: To preserve humeral bone during RTSA, stems have been made shorter and cement avoided whenever possible. However, with the increased use of uncemented RTSA, a phenomenon comparable to the stress shielding of the hip has been described for the proximal humerus. The aim of this study was to investigate the influence of stem length and width on proximal humeral bone resorption after primary uncemented RTSA. MATERIALS AND METHODS: The prospective shoulder arthroplasty database of our institution was reviewed for all primary uncemented RTSAs from 2017 to 2020 in osteoarthritis and cuff tear arthropathy cases with > 2-year follow-up. We compared the clinical and the radiographic 2-year outcome of the short and standard length stems of the same prosthesis design. This allowed us to assess the effects of stem length and width with regard to stress shielding. Furthermore, we defined a cut-off value for the filling ratios to prevent stress shielding. RESULTS: Fifty patients were included in the analysis, nineteen were in the short stem group (SHORT) and thirty-one in the standard stem group (STANDARD). After 2 years, SHORT showed a relative Constant Score of 91.8% and STANDARD of 98.3% (p = 0.256). Stress shielding was found in 4 patients (21%) in SHORT and in 16 patients (52%) in STANDARD (p = 0.03); it occurred more frequently in patients with higher humeral filling ratios (p < 0.05). The calculated cut-off to prevent stress shielding was 0.7 (± 0.03) for the metaphyseal and distal filling ratio. CONCLUSION: While short and standard stems for RTSA have good results after 2 years, we found a significant negative effect of higher length and width of the stem with regard to stress shielding. Even though the clinical effects of stress shielding have to be assessed, short stems should be chosen with a filling ratio at the metaphyseal and distal position below 0.7. LEVEL OF EVIDENCE (A RETROSPECTIVE CASE-CONTROL STUDY): III.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Articulación del Hombro , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Articulación del Hombro/cirugía , Estudios Retrospectivos , Estudios Prospectivos , Estudios de Casos y Controles , Resultado del Tratamiento , Húmero/cirugía
4.
Exp Physiol ; 108(10): 1259-1267, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37572028

RESUMEN

Long-term, intense endurance exercise training can occasionally induce endothelial micro-damage and cardiac fibrosis. The underlying mechanisms are incompletely understood. Twenty healthy, well-trained male participants (10 runners and 10 cyclists) performed a strenuous high-intensity interval training (HIIT) session matched by age, height, weight and maximal oxygen consumption. We assessed the acute exercise response of novel cardiac biomarkers of fibrosis [e.g., galectin-3 (Gal-3) and soluble suppression of tumorigenicity 2 (sST2)] per exercise modality and their relationship with haemodynamic contributors, such as preload, afterload and cardiac contractility index (CTi), in addition to endothelial damage by sustained activation and shedding of endothelial cells (ECs). Serum Gal-3 and sST2 concentrations were investigated by enzyme-linked immunosorbent assays; haemodynamics were analysed via impedance plethysmography and circulating ECs by flow cytometry. The Gal-3 and sST2 concentrations and ECs were elevated after exercise (P < 0.001), without interaction between exercise modalities. Circulating Gal-3 and sST2 concentrations both showed a positive relationship with ECs (rrm  = 0.68, P = 0.001 and rrm  = 0.57, P = 0.010, respectively, both n = 18). The EC association with Gal-3 was significant only in cyclists, but equally strong for both modalities. Gal-3 was also related to exercise-induced CTi (rrm  = 0.57, P = 0.011, n = 18). Cardiac wall stress is increased after an acute HIIT session but does not differ between exercise modalities. Exercise-released Gal-3 from cardiac macrophages could very probably drive systemic endothelial damage, based on an enhanced CTi. The importance of acute exercise-induced vascular resistances and cardiac contractility for the release of fibrotic biomarkers and any long-term pathological endothelial adaptation should be investigated further, also relative to the exercise modality. NEW FINDINGS: What is the central question of this study? Circulating biomarkers of cardiac wall stress and fibrosis are influenced by physical exercise. The underlying mechanisms per exercise modality are still unclear. What is the main finding and its importance? We show that galectin-3 (Gal-3) and soluble suppression of tumorigenicity 2 (sST2) are increased after acute exercise but do not differ between running and cycling. One haemodynamic contributor to the secretion of Gal-3 is an enhanced cardiac contractility. Acute exercise-released Gal-3 and sST2 are linked to sustained endothelial activation and cell shedding. This could be relevant in the context of fibrosis development and could identify athletes at risk for pathological endothelial adaptations.


Asunto(s)
Células Endoteliales , Galectina 3 , Humanos , Masculino , Proteína 1 Similar al Receptor de Interleucina-1 , Biomarcadores , Fibrosis , Ejercicio Físico
5.
Int Orthop ; 46(6): 1341-1349, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35353240

RESUMEN

PURPOSE: Some patients show severe humeral bone stress shielding even one year after press-fit humeral stem, which can be a risk factor for implant durability. This study compared humeral stress shielding and clinical outcomes between high and low filling ratio (HFR and LFR) stems in primary reverse shoulder arthroplasty (RSA). METHODS: From 2015 to 2020, 104 patients who underwent RSA with a non-cemented standard-length humeral stem were examined. The humeral stems included large press-fit stems (HFR group, 53 patients) or small non-press-fit stems with autogenous cancellous bone grafting (LFR group, 51 patients). The radiologic and clinical outcomes were compared between the groups one year post-operatively. RESULTS: One patient in the LFR group with early infectious dislocation was excluded from the 1-one year evaluation. No stress shielding was observed in 27/50 (54.0%) and 5/53 (9.4%) of patients in the LFR and HFR groups, while 3/50 (6%) and 19/53 (35.8%) patients showed high-stress shielding, respectively. However, the stem alignment change, subsidence, complications and evidence of loosening did not differ between the groups. The final range-of-motion and functional scores were significantly poorer in the LFR group than those in the HFR group, although the difference was minimal. CONCLUSION: Even at one year follow-up, patients receiving LFR stems with autogenous bone grafting had significantly less humeral stress shielding compared to patients with HFR stem with press-fit in primary RSA, without compromising stem stability.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Articulación del Hombro , Prótesis de Hombro , Artroplastía de Reemplazo de Hombro/efectos adversos , Humanos , Húmero/cirugía , Rango del Movimiento Articular , Estudios Retrospectivos , Articulación del Hombro/cirugía , Prótesis de Hombro/efectos adversos , Resultado del Tratamiento
6.
Environ Res ; 194: 110614, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33345900

RESUMEN

The moving bed biofilm reactor (MBBR) has certain advantages, such as high wastewater treatment efficiency, low maintenance and operating costs, and simple operation. It has emerged as a valuable option for small decentralized facilities. The filling ratio, aeration mode and aeration intensity are the main factors that affect the performance of MBBRs in wastewater treatment. However, the information that concerns the used criteria that pertain to the process design for the MBBR is not adequate. In this study, a three dimensional computational fluid dynamics (CFD) model was constructed and the maximum error was only 1.98%, which was much smaller than the traditional 2D-CFD model. The filling ratio, aeration mode and aeration intensity of MBBR were optimized by CFD model from the point of view of fluid mechanics. The results show that the fluidization performance of the filling is the best under the one-side aeration mode with 30% filling ratio. The cost-performance ratio of the reactor with 30% filling ratio was 1.53, 25% and 35% filling ratio were only 1.17 and 1.14 respectively. Increasing the aeration intensity could improve the fluidization performance. However, the effect of high aeration intensity on the fluidization performance of the carrier was limited and the energy consumption increased greatly. The results revealed that when the aeration intensity increased from 0.07 min-1 to 0.13 min-1, the proportion of the carrier area increased by 16.56%. The proportion of the carrier area with an aeration rate of 0.20 min-1 was only 4.23%, which is higher than 0.13 min-1. The main factors that control the fluidization of the carrier were the range of the flow zone and the flow velocity of the liquid. Increasing the range of the flow zone could facilitate the flow of the carriers. The critical value of the flow velocity of the liquid in the flow zone was 0.04 m/s. These results could guide the optimization design of the filling ratio and the aeration conditions and provide a theoretical basis for the application of MBBR.


Asunto(s)
Biopelículas , Purificación del Agua , Reactores Biológicos , Hidrodinámica , Eliminación de Residuos Líquidos , Aguas Residuales
7.
Arch Orthop Trauma Surg ; 141(2): 183-188, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32221702

RESUMEN

INTRODUCTION: Shorter humeral reverse total shoulder arthroplasty (RTSA) stems may reduce stress shielding, however, potentially carry the risk of varus/valgus malalignment. This radiographic study's purpose was to measure the incidence of stem malalignment and thus the realized neck-shaft angle (NSA). The hypothesis was that malalignment of the stem is a frequent postoperative radiographic finding. METHODS: Radiographs of an uncemented curved short stem RTSA with a 145° NSA were reviewed. The study group included 124 cases at a mean age of 74 (range 48-91) years. The humeral stem axis was measured and defined as neutral if the value fell within ± 5° of the longitudinal humeral axis. Angular values > 5° were defined as malaligned in valgus or varus. The filling ratio of the implant within the humeral shaft was measured at the level of the metaphysis (FRmet) and diaphysis (FRdia). RESULTS: The average humeral stem axis angle was 4 ± 3° valgus, corresponding to a true mean NSA of 149 ± 3°. Stem axis was neutral in 73% (n = 90) of implants. Of the 34 malaligned implants, 82% (n = 28) were in valgus (NSA = 153 ± 2°) and 18% (n = 6) in varus (NSA = 139 ± 1°). The average FRmet and FRdia were 0.68 ± 0.11 and 0.72 ± 0.11, respectively. A low positive association was found between stem diameter and filling ratios (r = 0.39; p < 0.001); indicating smaller stem sizes were more likely to be misaligned. CONCLUSION: Uncemented short stem implants may decrease stress shielding; however, approximately one quarter were implanted > 5° malaligned. The majority of malaligned components (86%) were implanted in valgus, corresponding to an NSA of > 150°. As such, surgeons must be aware that shorter and smaller stems may lead to axial malalignment influencing the true SA. LEVEL OF EVIDENCE: Level IV, retrospective study.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Húmero/cirugía , Prótesis Articulares , Adulto , Anciano , Anciano de 80 o más Años , Artroplastía de Reemplazo de Hombro/efectos adversos , Artroplastía de Reemplazo de Hombro/instrumentación , Humanos , Persona de Mediana Edad , Complicaciones Posoperatorias , Estudios Retrospectivos
8.
BMC Oral Health ; 21(1): 467, 2021 09 23.
Artículo en Inglés | MEDLINE | ID: mdl-34556097

RESUMEN

BACKGROUND: Dental caries have a serious impact on general health and well-being; however, there is a lack of relevant data on the development trends of dental caries in permanent teeth among 12-year-old children in China. We aim to assess long-term trends of dental caries in permanent teeth among 12-year-old children in China and identify the susceptible subgroups based on five consecutive national surveys from 1995 to 2014. METHODS: A total of 88 972 subjects were extracted from five consecutive national surveys (1995, 2000, 2005, 2010, 2014). Standardized dental examinations were conducted and the oral health status of each subject was recorded. The prevalence of Decayed, Missing and Filled teeth (DMF%), mean Decayed, Missing, Filled teeth score (DMFT) and Caries Filling Ratio (CFR) were used as measurement indicators. Cochran-Armitage trend test was used to evaluate the trends in DMF% and CFR, and multivariate linear regression was used to evaluate the trends in DMFT. RESULTS: A V-shaped fluctuating upward trend in DMF% during 1995-2014 was observed (Z = - 13.124, P < 0.001), and the DMF% in 1995-2014 was 21.1%, 15.9%, 16.2%, 21.9% and 24.3%. The trend in DMFT was approximately consistent with DMF% (ß = 0.057, P < 0.001), but the downward volatility appeared in 2014. The DMFT in 1995-2014 was 0.38, 0.28, 0.31, 0.66 and 0.54. A continuously fluctuant trend in CFR was observed during past two decades (Z = 1.927, P > 0.05), and the CFR in 1995-2014 was 17.4%, 22.8%, 19.3%, 23.4% and 15.6%. The DMF% and DMFT of rural children had a larger absolute increase than that of urban children during 1995-2014 (DMF%-urban: Z = - 0.242, P > 0.05; DMF%-rural: Z = - 19.036, P < 0.001; DMFT-urban: ß = 0.035, P < 0.001, DMFT-rural: ß = 0.077, P < 0.001). The DMF% and DMFT in girls were higher than that in boys at each survey year (P < 0.001). CFR of urban children was higher than that of rural children at each survey year (P < 0.001). CONCLUSIONS: Over the past 20 years, DMFT and DMF% of 12-year-old children in China presented V-shaped fluctuant upward trends, with a decline trend from 1995 to 2000 and an upward trend from 2000 to 2014. CFR had no significant improvement. The rural children and girls are the more vulnerable groups in the development of dental caries and need to pay priority. Our study supports the continuation of policies to improve children' oral health.


Asunto(s)
Caries Dental , Niño , China/epidemiología , Índice CPO , Caries Dental/epidemiología , Dentición Permanente , Femenino , Humanos , Masculino , Prevalencia , Población Rural
9.
BMC Musculoskelet Disord ; 21(1): 15, 2020 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-31914984

RESUMEN

BACKGROUND: Extension stems provide stability to revision total knee arthroplasty (RTKA). Little is known regarding the relationship between stem characteristics and RTKA stability. We aimed to identify the relationship between canal filling ratio (CFR) and aseptic loosening following RTKA. METHODS: We retrospectively reviewed demographics, radiographic parameters, and outcomes associated with RTKA performed between 2008 and 2013 in a tertiary hospital. The inclusion criteria were: revision for aseptic loosening, hybrid fixation, minor bone defect, Zimmer® LCCK prosthesis, and follow-up > 24 months. Using the modified Knee Society radiographic scoring system, radiographic prosthesis loosening was defined as a radiolucent line (RLL) score ≥ 9 on the femoral side or ≥ 10 on the tibial side. We utilized receiver operating characteristic (ROC) curve analysis to evaluate the cutoff value for stem length and diameter in terms of prosthesis loosening or not. Furthermore, CFR-related parameters were analyzed with logistic regression to clarify their relationships with prosthesis loosening. RESULTS: Prosthesis loosening was detected in 17 of 65 patients included. On logistic regression analysis, male sex and severity of the tibial bone defect were associated with loosening. On multivariate analysis, male sex and bone defect severity were associated with loosening on the femoral side, while malalignment was associated with loosening on the tibial side. Protective factors included femoral CFR > 0.85, CFR > 0.7 for > 2 cm, and CFR > 0.7 for > 4 cm, as well as tibial CFR > 0.85. CONCLUSIONS: To minimize loosening post-RTKA, femoral CFR > 0.7 for > 2 cm and tibial CFR > 0.85 are recommended. Risk factors may include male sex, bone defect severity, and malalignment.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/efectos adversos , Fenómenos Biomecánicos , Femenino , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/fisiopatología , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Falla de Prótesis , Recuperación de la Función , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
10.
Eur J Appl Physiol ; 119(11-12): 2435-2447, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31701273

RESUMEN

PURPOSE: To characterize left ventricular diastolic function during an exertional challenge in adults with incomplete cervical spinal cord Injury (icSCI). METHODS: In this cross-sectional study, a two-group convenience sample was used to compare left ventricular LV diastolic performance during a 5-10 W·min-1 incremental arm ergometer exercise protocol, using bioimpedance cardiography. Subjects were eight males with cervical incomplete spinal cord injury (icSCI; C5-C7: age 39 ± 14 years) versus eight able-bodied males (CON: age 38 ± 13 years). Left ventricular (LV) diastolic indices included end-diastolic volume (EDV) and early diastolic filling ratio (EDFR). LV ejection time (LVET), inotropic index (dZ/dT2) and stroke volume (SV) were compared between the groups at peak exercise, and maximum workload for the icSCI group (isomax). RESULTS: EDV (at peak exercise:131.4 ± 7.3 vs 188.78 ± 9.4, p < 0.001; at isomax: 131.4 ± 7.3 vs 169 ± 23, p = 0.0009) and EDFR (at peak exercise 73 ± 14% vs 119 ± 11%, p = 0.006; at isomax 94 ± 10; p = 0.009) were significantly reduced in icSCI compared to CON, respectively. Significant differences in LVET (icSCI: 273 ± 48 vs CON: 305 ± 68; p = 0.1) and dZ/dT2 (icSCI: 0.64 ± 0.11 vs CON: 0.85 ± 0.31; p = 0.1) were not observed at isomax, despite a significant decrease in SV in the subjects with icSCI (77.1 ± 6.05 mL vs 105.8 ± 9.2 mL, p < 0.00) CONCLUSION: Left ventricular filling was impaired in the subjects with icSCI as evidenced at both peak exercise and isomax. It is likely that restrictions on the skeletal muscle pump mechanized the impairment but increased left ventricular wall stiffness could not be excluded as a mediator.


Asunto(s)
Ejercicio Físico/fisiología , Ventrículos Cardíacos/fisiopatología , Traumatismos de la Médula Espinal/fisiopatología , Función Ventricular Izquierda/fisiología , Adolescente , Adulto , Anciano , Gasto Cardíaco/fisiología , Estudios Transversales , Diástole/fisiología , Prueba de Esfuerzo/métodos , Terapia por Ejercicio/métodos , Tolerancia al Ejercicio/fisiología , Femenino , Corazón/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Volumen Sistólico/fisiología , Adulto Joven
11.
J Shoulder Elbow Surg ; 25(4): 650-7, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26560021

RESUMEN

BACKGROUND: This study evaluated the timing and location of radiologic bone adaptations related to shoulder arthroplasty using a single type of cementless short-stem shoulder prosthesis. METHODS: Uncemented short-stem shoulder arthroplasties were evaluated in 52 patients at a mean age of 71.6 years (range, 58.1-86.6) with a minimum clinical and radiologic follow-up of 2 years (mean, 32 months; range, 23-52 months). All radiographs were analyzed for inclination of the stem, filling ratio of metaphysis and diaphysis, bone remodeling around the stem, radiolucent lines around the glenoid, and subsidence of the humeral stem. Finally, the radiographic and clinical findings were compared between patients with low and high bone adaptations. RESULTS: At final follow-up, no loosening, subsidence, or osteolysis was seen. High bone adaptations were present in 27 patients (51.9%). Cortical thinning and osteopenia in the medial cortex (82.7%) and spot welds in the lateral cortex (78.6%) were the most frequently occurring bone adaptations. Patients with high bone adaptations had significantly higher metaphyseal (0.60 ± 0.05 vs. 0.56 ± 0.06; P = .024) and diaphyseal filling ratio (0.66 ± 0.04 vs. 0.61 ± 0.06; P = .019) at 2-year follow-up than patients with low bone adaptations. Clinical outcome was not influenced by the radiographic changes. CONCLUSION: The clinical and radiologic results of the short-stem shoulder arthroplasty are comparable to those with the third and fourth generations of standard stem arthroplasty. Higher filling ratios in the metaphysis and the diaphysis were significantly associated with the occurrence of high bone adaptations.


Asunto(s)
Artroplastia de Reemplazo , Remodelación Ósea , Húmero/fisiopatología , Prótesis Articulares , Osteoartritis/cirugía , Articulación del Hombro/cirugía , Anciano , Anciano de 80 o más Años , Resorción Ósea/diagnóstico por imagen , Femenino , Humanos , Húmero/cirugía , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Radiografía , Resultado del Tratamiento
12.
Micromachines (Basel) ; 15(6)2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38930734

RESUMEN

As the thickness of an ultra-thin flattened heat pipe (UTHP) decreases, the fabrication difficulty increases exponentially, and the thermal performance deteriorates rapidly. In this study, three types of composite wicks were developed for UTHPs with a 0.6 mm thickness: copper foam and mesh wick (CFMW), two layers of different mesh wick (TDMW), and three layers of the same mesh wick (TSMW). The startup and steady-state performances of the UTHPs with liquid filling ratios of 60% to 120% were investigated. The findings indicated that the CFMW UTHP with a filling ratio of 100% exhibited the best startup performance, with the highest equilibrium temperature of 58.37 °C. The maximum heat transport capacities of the CFMW, TDMW, and TSMW UTHP samples were 9, 8, and 8.5 W, respectively, at their corresponding optimum filling ratios of 110%, 90%, and 100%. The CFMW UTHP exhibited the lowest evaporation and condensation thermal resistances of 0.151 and 0.189 K/W, respectively, which were 24.67% and 41.85% lower than those of the TSMW UTHP. CFMW can be used to improve the thermal performance of UTHPs. This study provides important guidelines for the structural design, fabrication technology, and performance improvement of high-performance UTHPs used in portable electronic devices.

13.
JSES Int ; 8(5): 1077-1086, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39280137

RESUMEN

Background: Several factors affect the incidence of osteopenia with cortical narrowing (CNO) in reverse shoulder arthroplasty. This study aimed to compare the incidence of CNO with different fixation methods (cemented or cementless) using a single implant (trabecular metal humeral stem) evaluated using tomosynthesis and to analyze the factors affecting the incidence of CNO for cementless stem fixation. Methods: A total of 109 patients (cementless: 75 cases; cemented: 34 cases) who underwent reverse total shoulder arthroplasty were included in this study. The patients were divided into 2 groups (cementless or cemented), and the incidence of CNO was compared. In addition, patients in the cementless group were divided into 2 groups (canal filling ratio [CFR] of ≥ 0.7 or < 0.7), the incidence of CNO was compared, and the Cramer's coefficient of association between CNO and CFR > 0.7 (and 0.8) was calculated. Results: No significant difference was observed in the incidence of CNO between the cementless and cemented groups (7/75 vs. 3/35, P value = 1.0). The association between CNO and the CFR using Cramer's coefficient of association showed that there were few correlations (coefficient: 0.14, P value = .59). Conclusion: Cementless reverse total shoulder arthroplasty with a trabecular metal stem has a similar low incidence of CNO as cemented fixation, and the incidence of CNO with a trabecular metal stem was lower than that reported in previous studies. A CFR > 0.7 was not associated with the incidence of CNO.

14.
Front Endocrinol (Lausanne) ; 15: 1359550, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38800478

RESUMEN

Objective: To explore the appropriate bone cement filling ratio in percutaneous kyphoplasty (PKP) for the treatment of osteoporotic vertebral compression fractures (OVCF). Methods: Clinical and radiological data from 150 OVCF patients treated with PKP were retrospectively analyzed. Patients were categorized into three groups based on bone cement filling ratio: low (<0.4), medium (0.4-0.6), and high (>0.6) filling ratio groups. The clinical characteristics (age, gender, BMI, etc.) and related study data (bone cement leakage and its location, pre/post-operative Visual Analogue Scale (VAS), pre/post-operative Oswestry Disability Index (ODI), vertebral height restoration, kyphotic Cobb angle, etc.) among the three groups were compared using statistical software to compare to identify the most appropriate cement filling ratio. Results: The 0.4-0.6 group presented a lower cement leakage rate compared to the >0.6 group, and there were no significant differences in pre-operative VAS, post-operative day 2 VAS, post-operative month 1 VAS, and pre-operative ODI (p>0.05). However, significant differences were observed in post-operative month 3 VAS (p=0.002), post-operative day 2 ODI (p=0.002), post-operative month 1 ODI (p<0.001), and post-operative month 3 ODI (p<0.001). The "0.4-0.6" group showed better pain improvement and functional recovery compared with the ">0.6" group at the 3-month follow-up. While presenting the best vertebral height restoration, the ">0.6" group also exhibited the greatest variability. Additionally, no significant difference in Cobb angle changes was observed among the groups. Conclusion: A bone cement filling ratio of 0.4-0.6 in PKP treatment for OVCF strikes a favorable balance between complication reduction and positive patient outcomes, warranting it as an optimal filling volume.


Asunto(s)
Cementos para Huesos , Fracturas por Compresión , Cifoplastia , Fracturas Osteoporóticas , Fracturas de la Columna Vertebral , Humanos , Cifoplastia/métodos , Fracturas Osteoporóticas/cirugía , Femenino , Cementos para Huesos/uso terapéutico , Masculino , Anciano , Estudios Retrospectivos , Fracturas de la Columna Vertebral/cirugía , Fracturas por Compresión/cirugía , Fracturas por Compresión/diagnóstico por imagen , Anciano de 80 o más Años , Resultado del Tratamiento , Persona de Mediana Edad , Estudios de Seguimiento
15.
JSES Int ; 8(1): 119-125, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38312281

RESUMEN

Background: There are numerous reports of bone adaptation observed on plain radiography studies after the use of cementless short stems in reverse shoulder arthroplasty. However, reports on changes in bone mineral density (BMD) around the stem using dual-energy X-ray absorptiometry (DEXA) are prominently absent. In the present study, we measured BMD around the stem using DEXA and investigated changes over time from postoperative year 1 to year 2. Additionally, the relationship between BMD changes, filling ratio, and stem alignment was examined. Methods: Forty-seven patients with short cementless stems who could be assessed via DEXA at 1-2 years postoperatively were included. After dividing the zones around the stem into 5, the BMD in each zone was measured, in addition to BMD changes and amount of change from postoperative year 1 to year 2. The relationship between filling ratio and stem alignment on postoperative plain radiography was assessed. Results: A significant decrease in BMD in zone 3 was observed between postoperative year 1 and year 2 (P = .02). Regarding filling ratio and stem alignment, a negative correlation between valgus stem alignment and BMD change observed in zone 1 (r = -0.470, P < .01). In addition, stem valgus greater than 6° correlated with a significant decrease in BMD in zone 1. (P = .01). No significant differences were found in the other zones. Furthermore, there was no correlation between filling ratio and BMD change. Conclusion: In reverse shoulder arthroplasty cementless short stems, changes that that occurred between postoperative year 1 to year 2 demonstrated a decrease in BMD in zone 3. In addition, a decrease in BMD in zone 1 was observed with a stem alignment of valgus 6° or higher, suggesting that stem alignment within valgus 6° is required to prevent a decrease in BMD.

16.
Materials (Basel) ; 16(2)2023 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-36676574

RESUMEN

With the active development of offshore wind power worldwide, the development of a green and ecofriendly grouting material (GEGM) has garnered global attention. Such a material must also be developed in Taiwan. Therefore, in this study, a series of environmentally friendly recycled materials were mixed in different proportions to develop a GEGM which can be implemented in the future construction of offshore wind turbines. To evaluate the mechanical properties of the GEGM, low water-to-binder (W/B) ratios (i.e., 0.21, 0.27, and 0.35) were used; cement was replaced with fixed amounts (20%) of ground granulated blast-furnace slag and fly ash; 2%, 2.5%, and 3% superplasticizers (SPs) were added; and two levels of sand content (60% and 70%) were used. The setting time of the GEGM was used to evaluate its workability; its compressive strength and flexural strength were used to evaluate its mechanical properties; and its sulfate resistance, length changes, and four-terminal resistance were used to evaluate its durability. The relationship between the durability and drying shrinkage of the GEGM was subsequently evaluated, and the ratio of final to initial setting times (F/I value) was calculated to determine the effects of the amount of SP added on workability. The highest F/I value (7.7) was achieved when 2 wt.% modified lignin sulfonate (MLS) was added because of the high viscosity of MLS, which compromised the workability of the concrete. The optimal compressive strength (83.62 MPa) was achieved when a W/B ratio of 0.21 was used, when the sand content was 70%, and when a 2% polycarboxylate superplasticizer (PCE) was added, whereas the optimal flexural strength (20.86 MPa) was achieved when 2.5% PCE was added. According to the nondestructive test results and the R2 value (>0.7) obtained from regression analyses of mechanical properties, the study results are reliable and may serve as a reference for future construction projects.

17.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 37(6): 641-646, 2023 Jun 15.
Artículo en Zh | MEDLINE | ID: mdl-37331936

RESUMEN

Objective: Using the mono-energy reconstruction images and X-ray films to investigate whether the ABG Ⅱ short-stem could improve the filling ratio, stability, and alignment in the Dorr type C femur, compared with the Corail long-stem. Methods: Among patients who were with Dorr type C femurs and treated with total hip arthroplasty between January 2006 and March 2012, 20 patients with a Corail long-stem (Corail group) and 20 patients with an ABG Ⅱ short-stem (ABG Ⅱ group) were randomly selected. The differences in gender, age, body mass index, and preoperative diagnoses between the two groups were not significant ( P>0.05). The ABG Ⅱ group was with a mean follow-up of 142 months (range, 102-156 months), and the Corail group was with a mean follow-up of 107 months (range, 91-127 months). There was no significant difference in the Harris score and subjective satisfaction score between the two groups at last follow-up ( P>0.05). At last follow-up, dual-energy CT scans with mono-energy image reconstruction were used to calculate the prosthetic filling ratio and to measure the alignment of the prosthesis in the coronal and sagittal positions. Stability assessment was performed based on X-ray films, and the subsidence distance was measured using EBRA-FCA software. Results: X-ray film observation showed that the prostheses in the two groups were stable and no signs of loosening was found. The incidence of pedestal sign was significantly lower in the ABGⅡ group than in the Corail group ( P<0.05), and the incidence of heterotopic ossification was significantly higher in the ABGⅡ group than in the Corail group ( P<0.05). The subsidence distance of femoral stem in ABG Ⅱ group was significantly greater than that in Corail group ( P<0.05), and the subsidence speed of femoral stem in ABG Ⅱ group was also greater than that in Corail group, but the difference was not significant ( P>0.05). The overall prosthesis filling ratio was significantly higher in the ABG Ⅱ group than in the Corail group ( P<0.05), while the coronal filling ratio at the lesser trochanter, 2 cm below the lesser trochanter, and 7 cm below the lesser trochanter were not significant ( P>0.05). The results of prosthesis alignment showed that there was no significant difference in the sagittal alignment error value and the incidence of coronal and sagittal alignment error >3° between the two groups ( P>0.05), while the coronal alignment error value in the ABG Ⅱ group was significantly greater than that in the Corail group ( P<0.05). Conclusion: Although the ABG Ⅱ short-stem avoids the distal-proximal mismatch of the Corail long-stem in the Dorr type C femur and thus achieves a higher filling ratio, it does not appear to achieve better alignment or stability.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Fémur/diagnóstico por imagen , Fémur/cirugía , Extremidad Inferior/cirugía , Diseño de Prótesis , Estudios Retrospectivos
18.
Environ Sci Pollut Res Int ; 30(10): 26764-26777, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36370308

RESUMEN

Underground resource exploitation has seriously damaged the surface ecological environment and underground water system. As an effective control measure, the filling mining process has greatly reduced the surface subsidence. As a branch of the filling mining process, the continuous mining and continuous backfilling (CMCB) method solves the contradiction of mining and filling in this process. The control index of filling ratio of even number lane (FRE) was presented to investigate the technical advantages of the CMCB method. The numerical analysis model was used to investigate the laws such as deformation characteristics of the surrounding rock, stress distribution, and plastic area distribution characteristics of backfill under four typical cases. As a consequence, the FRE effect law on overburden deformation and the roof control function of the backfill was disclosed, and overburden rock deformation control solutions were provided. According to the results, the overburden deformation varies dramatically when the FRE decreases, and it rises greatly when the even-numbered lane backfill (ELB) is not contacted with the roof. The contacting condition and filling condition of the odd numbered lane backfill (OLB) are connected to the distribution of stress and plastic zone. The backfill transmits the rock beam load by building a composite support system with the roof and floor rock layers, and it accomplishes the backfill's roof control function by combining the primary and secondary load-bearing and synergistic load-bearing connections between the backfills. Measures such as differential FRE, differential strength, non-uniformity of filling lane, and synergistic bearing of temporary support and backfill may help to decrease deformations and internal cracks in the surrounding rock. This measure has been successfully implemented in the field, serving as an experience for the application of the CMCB method.


Asunto(s)
Ambiente , Agua Subterránea , Minería , Soporte de Peso , Minería/métodos
19.
Heliyon ; 9(4): e14840, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37025813

RESUMEN

The high nutrient concentration in domestic wastewater effluent can endanger the aquatic life via eutrophication. Thus, research have been carried out to prevent harm to aquatic life. In regard biofilm reactors have been successful by far with few limitations. Bio-carrier fabrication of desired shape is one of the limitations. Recently, the invention of additive manufacturing (AM) of object made it feasible to fabricate the desired shape. In this study additive manufactured bio‒carrier (AMB) was printed using AM technique, with high surface area to volume ratio as well as density higher than water. The submerged attach growth sequencing batch biofilm reactor (SAGSBBR) for organic and nutrient removal from domestic wastewater (DWW) was conducted to determine the optimum bio‒carrier filling ratio (FR) and cycle time (CT) by using response surface methodology (RSM) with CT ranging between 12 h and 24 h and FR ranging between 0 and 20%. The maximum chemical oxygen demand (COD), ammonia-nitrogen (NH4 +‒N), and total phosphorus (TP) removal was 96.8 mg/L, 93.32 mg/L, and 88.89 mg/L respectively, which was achieved in submerged attached growth sequential biofilm batch reactor with 10% FR (SAGSBBR‒10). The optimization study determined the optimal solution of CT and FR to be 17.07 h and 12.38% respectively, with desirability of 0.987. The predicted mean of responses for the optimal solution were 96.64%, 94.40% and 89.94% for COD removal, NH4 +‒N removal and TP removal, respectively. The rate of biomass attachment at the first stage in SAGSBBR‒10 and SAGSBBR‒20 was about 11.39 mg/carrier.d and 8.64 mg/carrier.d, whereas the highest accumulation achieved was 98.27 mg/carrier and 80.15 mg/carrier respectively. Thus, this study can assist us to achieve sustainable development goal (SDG) 6.

20.
Int J Pharm ; 622: 121861, 2022 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-35643345

RESUMEN

Understanding die filling behaviour of powders is critical in developing optimal formulation and processes in various industries, such as pharmaceuticals and fine chemicals. In this paper, forced die filling is analysed using a graphics processing unit (GPU) based discrete element method (DEM), for which a powder feeder equipped with a wired stirrer is considered. The influences of operating parameters, such as the initial powder bed height, the filling speed, and the stirrer speed, on the die filling performance are systematically explored. It is shown that a larger initial powder bed height leads to a higher filling ratio, which can be attributed to a higher filling intensity; while the deposited particle mass in the die is almost independent of the powder bed height, when the initial fill level is larger than a critical bed height. Additionally, the filling ratio slightly increases with the increase of stirrer speed for cases with a stirrer, while the filling ratios are lower than that without a stirrer, which is attributed to the stirrer occupying some space above the die and reducing the effective discharge area. The obtained results can provide useful information for optimising the feeder system design and the operating condition.


Asunto(s)
Excipientes , Gravitación , Polvos , Tecnología Farmacéutica/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA