Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Acta Neurochir Suppl ; 135: 27-31, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38153445

RESUMEN

In forensic investigations, the limitations of the traditional purely autoptic approach can be overcome through post-mortem imaging (virtopsy). Virtospy has several applications to the investigation of brain and spinal injuries, whose analysis can be of forensic interest, especially in cases of suspected malpractice. In this scoping review, we briefly describe the main applications of the two most common post-mortem radiological techniques (computed tomography (CT) and magnetic resonance imaging (MRI)) to the forensic investigation of brain and spinal injuries in cases of medical malpractice or traumatic (accidental/homicidal/suicidal) deaths. Although CT represents the traditional approach to post-mortem imaging, MRI is proving to be a valuable tool to investigate brain and spinal injuries and lesions. These post-mortem radiological techniques can also be used to guide the surgeons in simulated surgical procedures on corpses in the context of training programs, thus helping operators to improve technical and non-technical skills and to reduce the risk of avoidable errors.


Asunto(s)
Lesiones Encefálicas , Traumatismos Vertebrales , Humanos , Imágenes Post Mortem , Columna Vertebral , Encéfalo/diagnóstico por imagen
2.
Sci Justice ; 58(6): 386-396, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30446067

RESUMEN

An investigation into the effects of physical and chemical enhancement on subsequent presumptive and confirmatory tests for human blood is presented. Human blood was deposited onto porous (white 80 gsm paper and brown envelope) and non-porous (tile and linoleum) substrates in a depletion series (30 depletions on non-porous and 20 on porous) and subjected to three ageing periods; 1, 7 and 28 days. A number of enhancement techniques were tested [fluorescence, black magnetic powder (BMP), iron-oxide black powder suspension (PS), cyanoacrylate (CA) fuming, acid violet 17 (AV17), acid yellow 7 (AY7), ninhydrin, DFO and Bluestar Forensic Magnum (BFM) luminol] to evaluate their potential effects on subsequent presumptive and confirmatory tests. AV17 and Bluestar provided the best enhancement and fully enhanced all depletions in the series. The sensitivity of the Kastle-Meyer (KM) (presumptive), Takayama and RSID-Blood tests (confirmatory) was initially investigated to determine the range of detectable depletions. The KM test detected all depletions, whereas the Takayama test detected up to depletion 6 and RSID-Blood detected up to depletion 20 (paper), 10 (envelope), 15 (tile) and 9 (lino). The abilities of these tests to detect blood after enhancement were then observed. A number of techniques resulted in little to no effect on any of the blood tests, whereas adverse effects were observed for others. Ninhydrin and CA fuming caused weak but instantaneous positive KM results whereas methanol-based AV17 and AY7 delayed the reaction by as much as 1 min. The Takayama test was not very sensitive, therefore, its performance was easily affected by enhancement and negative results were often observed. RSID-Blood tests were largely unaffected by chemical enhancement although a drop in positive results was observed for some of the techniques when compared to positive controls. Using a standard procedure for DNA extraction, all the tested blood samples (before and after enhancement) gave a detectable quantity of DNA and were successfully profiled. Out of the 45 samples processed for DNA profiling, 41 gave full profiles, while the remaining showed allele drop out in one or two loci.


Asunto(s)
Manchas de Sangre , Dermatoglifia del ADN/métodos , Indicadores y Reactivos/química , Cianoacrilatos , Fluorescencia , Humanos , Luminol , Ninhidrina , Polvos , Colorantes de Rosanilina , Sensibilidad y Especificidad , Factores de Tiempo
3.
Sci Justice ; 56(5): 305-320, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27702446

RESUMEN

There appears to be a limited but growing body of research on the sequential analysis/treatment of multiple types of evidence. The development of an integrated forensic approach is necessary to maximise evidence recovery and to ensure that a particular treatment is not detrimental to other types of evidence. This study aims to assess the effect of latent and blood mark enhancement techniques (e.g. fluorescence, ninhydrin, acid violet 17, black iron-oxide powder suspension) on the subsequent detection of saliva. Saliva detection was performed by means of a presumptive test (Phadebas®) in addition to analysis by a rapid stain identification (RSID) kit test and confirmatory DNA testing. Additional variables included a saliva depletion series and a number of different substrates with varying porosities as well as different ageing periods. Examination and photography under white light and fluorescence was carried out prior to and after chemical enhancement. All enhancement techniques (except Bluestar® Forensic Magnum luminol) employed in this study resulted in an improved visualisation of the saliva stains, although the inherent fluorescence of saliva was sometimes blocked after chemical treatment. The use of protein stains was, in general, detrimental to the detection of saliva. Positive results were less pronounced after the use of black iron-oxide powder suspension, cyanoacrylate fuming followed by BY40 and ninhydrin when compared to the respective positive controls. The application of Bluestar® Forensic Magnum luminol and black magnetic powder proved to be the least detrimental, with no significant difference between the test results and the positive controls. The use of non-destructive fluorescence examination provided good visualisation; however, only the first few marks in the depletion were observed. Of the samples selected for DNA analysis only depletion 1 samples contained sufficient DNA quantity for further processing using standard methodology. The 28-day delay between sample deposition and collection resulted in a 5-fold reduction in the amount of useable DNA. When sufficient DNA quantities were recovered, enhancement techniques did not have a detrimental effect on the ability to generate DNA profiles. This study aims to contribute to a strategy for maximising evidence recovery and efficiency for the detection of latent marks and saliva. The results demonstrate that most of the enhancement techniques employed in this study were not detrimental to the subsequent detection of saliva by means of presumptive, confirmative and DNA tests.


Asunto(s)
Saliva/química , Cromatografía de Afinidad , Colorantes , ADN/aislamiento & purificación , Dermatoglifia del ADN , Femenino , Fluorescencia , Medicina Legal , Humanos , Masculino , Ninhidrina , Colorantes de Rosanilina , Volatilización , Adulto Joven
4.
Forensic Sci Int ; 244: 231-46, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25277520

RESUMEN

Fingermarks, footwear marks, blood and semen are amongst the most commonly encountered types of evidence at crime scenes. Previous work has extensively investigated fingermark and blood enhancement techniques and a sequence developed to maximise evidence recovery; however, there is limited research as to the effect of these techniques on the subsequent detection of body fluids such as semen. In this study, seven fingermark and blood enhancement techniques (e.g. powder suspension, cyanoacrylate fuming and acid violet 17) were employed followed by the subsequent detection of semen/spermatozoa. Other variables included in the study were the use of two substrates (white ceramic tiles and grey laminate flooring), a depletion series and ageing periods of 1, 7, 14 and 28 days. The effect these techniques had on the subsequent detection of semen was assessed by visual and fluorescence examination followed by presumptive and confirmatory testing for semen and spermatozoa. The results found that protein stains (acid violet 17 and acid yellow 7) caused a loss in presumptive test reactivity; however, sperm heads were still observed using microscopic examination after extraction and staining. The use of black magnetic powder, Bluestar(®) Forensic Magnum luminol, Lumicyano™ 4% and cyanoacrylate fuming followed by basic yellow 40 staining did not hinder subsequent presumptive and confirmatory tests for semen and sperm heads. Powder suspension caused a loss in both presumptive test reactivity and sperm heads from the substrate. In general, the enhancement techniques resulted in the improved visualisation of the semen stains under white and violet/blue light. The results from this study aim to provide a strategy to maximise evidence recovery and improve efficiency in an integrated forensic approach.


Asunto(s)
Fluorescencia , Medicina Legal/métodos , Semen/citología , Espermatozoides/citología , Colorantes , Cianoacrilatos , Compuestos Férricos , Humanos , Sustancias Luminiscentes , Luminol , Masculino , Microscopía , Polvos , Colorantes de Rosanilina , Volatilización
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA