Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
2.
Trials ; 25(1): 493, 2024 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-39030640

RESUMEN

BACKGROUND: Aboriginal and Torres Strait Islander peoples are disproportionately impacted by type 2 diabetes. Continuous glucose monitoring (CGM) technology (such as Abbott Freestyle Libre 2, previously referred to as Flash Glucose Monitoring) offers real-time glucose monitoring that is convenient and easy to use compared to self-monitoring of blood glucose (SMBG). However, this technology's use is neither widespread nor subsidised for Aboriginal and Torres Strait Islander peoples with type 2 diabetes. Building on existing collaborations with a national network of Aboriginal and Torres Strait Islander communities, this randomised controlled trial aims to assess the effect of CGM compared to SMBG on (i) haemoglobin A1c (HbA1c), (ii) achieving blood glucose targets, (iii) reducing hypoglycaemic episodes and (iv) cost-effective healthcare in an Aboriginal and Torres Strait Islander people health setting. METHODS: This is a non-masked, parallel-group, two-arm, individually randomised, controlled trial (ACTRN12621000753853). Aboriginal and Torres Strait Islander adults with type 2 diabetes on injectable therapy and HbA1c ≥ 7.5% (n = 350) will be randomised (1:1) to CGM or SMBG for 6 months. The primary outcome is change in HbA1c level from baseline to 6 months. Secondary outcomes include (i) CGM-derived metrics, (ii) frequency of hypoglycaemic episodes, (iii) health-related quality of life and (iv) incremental cost per quality-adjusted life year gained associated with the CGM compared to SMBG. Clinical trial sites include Aboriginal Community Controlled Organisations, Aboriginal Medical Services, primary care centres and tertiary hospitals across urban, rural, regional and remote Australia. DISCUSSION: The trial will assess the effect of CGM compared to SMBG on HbA1c for Aboriginal and Torres Strait Islander people with type 2 diabetes in Australia. This trial could have long-term benefits in improving diabetes management and providing evidence for funding of CGM in this population. TRIAL REGISTRATION: Australian and New Zealand Clinical Trials Registry ACTRN12621000753853. Registered on 15th June 2021.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Análisis Costo-Beneficio , Diabetes Mellitus Tipo 2 , Hemoglobina Glucada , Adulto , Humanos , Australia , Aborigenas Australianos e Isleños del Estrecho de Torres , Biomarcadores/sangre , Glucemia/metabolismo , Diabetes Mellitus Tipo 2/sangre , Diabetes Mellitus Tipo 2/etnología , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/terapia , Hemoglobina Glucada/metabolismo , Hemoglobina Glucada/análisis , Control Glucémico , Hipoglucemia/sangre , Hipoglucemia/prevención & control , Hipoglucemiantes/uso terapéutico , Calidad de Vida , Ensayos Clínicos Controlados Aleatorios como Asunto , Factores de Tiempo , Resultado del Tratamiento
3.
Diabetes Technol Ther ; 25(12): 827-835, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37782139

RESUMEN

Objective: To investigate whether intermittently scanned continuous glucose monitoring (isCGM) reduced glycated hemoglobin (HbA1c) compared with capillary self-monitored capillary blood glucose (SMBG) in children with type 1 diabetes (T1D) and elevated glycemic control. Research Design and Methods: This multicenter 12-week 1:1 randomized, controlled, parallel-arm trial included 100 participants with established T1D aged 4-13 years (mean 10.9 ± 2.3 years) naive to isCGM and with elevated HbA1c 7.5%-12.2% [58-110 mmol/mol] [mean HbA1c was 9.05 (1.3)%] [75.4 (13.9) mmol/mol]. Participants were allocated to 12-week intervention (isCGM; FreeStyle Libre 2.0; Abbott Diabetes Care, Witney, United Kingdom) (n = 49) or control (SMBG; n = 51). The primary outcome was the difference in change of HbA1c from baseline to 12 weeks. Results: There was no evidence of a difference between groups for change in HbA1c at 12 weeks (0.23 [95% confidence interval; CI: -0.21 to 0.67], P = 0.3). However, glucose-monitoring frequency increased with isCGM +4.89/day (95% CI 2.97-6.81; P < 0.001). Percent time below range (TBR) <3.9 mmol/L (70-180 mg/dL) was reduced with isCGM -6.4% (10.6 to -4.2); P < 0.001. There were no differences in within group changes for Parent or Child scores of psychosocial outcomes at 12 weeks. Conclusions: For children aged 4-13 years with elevated Hba1c isCGM led to improvements in glucose testing frequency and reduced time below range. However, isCGM did not translate into reducing Hba1c or psychosocial outcomes compared to usual care over 12-weeks. The trial is registered within the Australian New Zealand Trial Registry on February 19, 2020 (ACTRN12620000190909p; ANZCTR.org.au) and the World Health Organization International Clinical Trials Registry Platform (Universal Trial Number U1111-1237-0090).


Asunto(s)
Diabetes Mellitus Tipo 1 , Humanos , Niño , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hemoglobina Glucada , Glucemia , Automonitorización de la Glucosa Sanguínea , Australia , Hipoglucemiantes/uso terapéutico
4.
J Vet Intern Med ; 37(5): 1703-1709, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37534946

RESUMEN

BACKGROUND: Continuous glucose monitoring systems have been validated for eu- and hyperglycemic cats. The FreeStyle Libre 2 (FSL2) is sufficiently accurate in people during hypoglycemia to guide critical treatment decisions without confirmation of blood glucose concentration (BG). OBJECTIVES: Assess FSL2 accuracy in cats with hypoglycemia. ANIMALS: Nine healthy, purpose-bred cats. METHODS: Hyperinsulinemic-hypoglycemic clamps were performed by IV infusion of regular insulin (constant rate) and glucose (variable rate). Interstitial glucose concentration (IG), measured by FSL2, was compared to BG measured by AlphaTrak2. Data were analyzed for all paired measurements (n = 364) and separately during stable BG (≤1 mg/dL/min change over 10 minutes). Pearson's r test, Bland-Altman test, and Parkes Error Grid analysis respectively were used to determine correlation, bias, and clinical accuracy (P < .05 considered significant). RESULTS: Overall, BG and IG correlated strongly (r = 0.83, P < .0001) in stable glycemia and moderately at all rates of change (r = 0.69, P < .0001). Interstitial glucose concentration underestimated BG in euglycemia, but the BG-IG difference was progressively smaller as BG decreased (12.9 ± 12.2, 8.8 ± 11.2, -3.2 ± 7.4, and -7.8 ± 5.2 mg/dL in the ranges of 80-120 [n = 64], 60-79 [n = 29], 50-59 [n = 71], and 29-49 mg/dL [n = 53], respectively). CONCLUSIONS: Although IG underestimates BG throughout most of the hypo-euglycemic range, IG generally overestimates BG in marked hypoglycemia (<60 mg/dL). It is therefore imperative to evaluate FSL2 results in this critical range with caution.


Asunto(s)
Enfermedades de los Gatos , Diabetes Mellitus Tipo 1 , Hipoglucemia , Humanos , Gatos , Animales , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea/veterinaria , Diabetes Mellitus Tipo 1/veterinaria , Glucosa , Hipoglucemia/veterinaria , Enfermedades de los Gatos/diagnóstico
5.
J Diabetes Sci Technol ; 16(1): 70-77, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32954812

RESUMEN

BACKGROUND: In this study, we evaluated the analytical performance of the second-generation factory-calibrated FreeStyle Libre Flash Glucose Monitoring (FreeStyle Libre 2) System compared to plasma venous blood glucose reference, Yellow Springs Instrument 2300 (YSI). METHODS: The study enrolled participants aged four and above with type 1 or type 2 diabetes at seven sites in the United States. Adult participants (18+ years) participated in three in-clinic sessions and pediatric participants (4-17 years) participated in up to two in-clinic sessions stratified to provide data for days 1, 2, 3, 7, 8, 9, 12, 13, or 14 of sensor wear. Participants aged 11+ underwent supervised glycemic manipulation during in-clinic sessions to achieve glucose levels across the measurement range of the System. Performance evaluation included accuracy measures such as the proportion of continuous glucose monitoring (CGM) values that were within ±20% or ±20 mg/dL of reference glucose values, and bias measures such as the mean absolute relative difference (MARD) between CGM and reference values. RESULTS: Data from the 144 adults and 129 pediatric participants were analyzed. Percent of sensor results within ±20%/20 mg/dL of YSI reference were 93.2% and 92.1%, and MARD was 9.2% and 9.7% for the adults and pediatric participants, respectively. The System performed well in the hypoglycemic range, with 94.3% of the results for the adult population and 96.1% of the data for pediatric population being within 15 mg/dL of the YSI reference. The time lag was 2.4 ± 4.6 minutes for adults and 2.1 ± 5.0 minutes for pediatrics. CONCLUSIONS: The System demonstrated improved analytical accuracy performance across the dynamic range during the 14-day sensor wear period as compared to the previous-generation device.NCT#: NCT03607448 and NCT03820050.


Asunto(s)
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Pediatría , Adulto , Anciano , Algoritmos , Glucemia , Automonitorización de la Glucosa Sanguínea , Niño , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Glucosa , Humanos , Reproducibilidad de los Resultados
6.
Diabetes Metab Syndr ; 15(5): 102265, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34488057

RESUMEN

AIMS: To determine the effectiveness of Freestyle Libre 2 (FSL2) on diabetes-self-management (DSM) practices and glycemic parameters among patients with type 1 diabetes (T1D) using insulin pump. METHODS: This prospective study was performed among 47 patients with T1D (13-21yrs) who self-tested their glucose levels by the conventional finger-prick method using blood glucose meters (BGM). Data related to glycemic profile i.e., mean time in range (TIR), mean time above range (TAR) mean time below range (TBR), mean glucose level, hemoglobin A1c (HbA1c), total daily dose of insulin (TDDI), frequency of glucose monitoring and DSM responses were collected at baseline and 12 weeks. RESULTS: The mean TIR was 59.8 ± 12.6%, TAR 32.7 ± 11.6%, TBR 7.5 ± 4.3%, mean glycemic variability, standard deviation 63.2 ± 12.5 mg/dL, and the coefficient of variation 41.3 ± 11.4% at 12 weeks. At baseline, the HbA1c level was 8.3%, and at 12 weeks, it dropped to 7.9% (p = 0.064). Baseline glucose monitoring frequency through BGM was 2.4/day; however, after the patients employed the FSL2, a higher degree of frequency of glucose monitoring was evident at 12 weeks as 8.2/day (p < 0.001). Significant improvements were observed in all the DSM subscales at 12 weeks. CONCLUSION: Using FSL2 was found to raise the patients' DSM levels and improved metabolic control.


Asunto(s)
Biomarcadores/sangre , Automonitorización de la Glucosa Sanguínea/métodos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Conductas Relacionadas con la Salud , Hipoglucemiantes/uso terapéutico , Sistemas de Infusión de Insulina/estadística & datos numéricos , Automanejo/métodos , Adolescente , Adulto , Glucemia/análisis , Diabetes Mellitus Tipo 1/patología , Diabetes Mellitus Tipo 1/psicología , Femenino , Hemoglobina Glucada/análisis , Humanos , Masculino , Pronóstico , Estudios Prospectivos , Adulto Joven
7.
J Diabetes Metab Disord ; 20(2): 2093-2101, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34900845

RESUMEN

PURPOSE: Frequent glucose monitoring is necessary for optimal glycaemic control. Second-generation intermittently scanned glucose monitoring (isCGM) systems inform users of out-of-target glucose levels and may reduce monitoring burden. We aim to compare FreeStyle Libre 2 (Abbott Diabetes Care, Witney, U.K.) to self-monitoring of blood glucose in children with type 1 diabetes and sub-optimal glycaemic control. METHODS: This open-label randomised controlled trial will enrol 100 children (4-13 years inclusive, diagnosis of type 1 diabetes ≥ 6 months, HbA1c 58-110 mmol/mol [7.5-12.2%]), from 5 New Zealand diabetes centres. Following 2 weeks of blinded sensor wear, children will be randomised 1:1 to control or intervention arms. The intervention (duration 12 weeks) includes second-generation isCGM (FreeStyle Libre 2) and education on using interstitial glucose data to manage diabetes. The control group will continue self-monitoring blood glucose. The primary outcome is the difference in glycaemic control (measured as HbA1c) between groups at 12 weeks. Pre-specified secondary outcomes include change in glucose monitoring frequency, glycaemic control metrics and psychosocial outcomes at 12 weeks as well as isCGM acceptability. DISCUSSION: This research will investigate the effectiveness of the second-generation isCGM to promote recommended glycaemic control. The results of this trial may have important implications for including this new technology in the management of children with type 1 diabetes. TRIAL REGISTRATION: This trial was prospectively registered with the Australian New Zealand Clinical Trials Registry on 19 February 2020 (ACTRN12620000190909p) and the World Health Organization International Clinical Trials Registry Platform (Universal Trial Number U1111-1237-0090).

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA