Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 444
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Mol Cell Proteomics ; 23(7): 100797, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38866076

RESUMEN

Targeted protein degradation is the selective removal of a protein of interest through hijacking intracellular protein cleanup machinery. This rapidly growing field currently relies heavily on the use of the E3 ligase cereblon (CRBN) to target proteins for degradation, including the immunomodulatory drugs (IMiDs) thalidomide, lenalidomide, and pomalidomide which work through a molecular glue mechanism of action with CRBN. While CRBN recruitment can result in degradation of a specific protein of interest (e.g., efficacy), degradation of other proteins (called CRBN neosubstrates) also occurs. Degradation of one or more of these CRBN neosubstrates is believed to play an important role in thalidomide-related developmental toxicity observed in rabbits and primates. We identified a set of 25 proteins of interest associated with CRBN-related protein homeostasis and/or embryo/fetal development. We developed a targeted assay for these proteins combining peptide immunoaffinity enrichment and high-resolution mass spectrometry and successfully applied this assay to rabbit embryo samples from pregnant rabbits dosed with three IMiDs. We confirmed previously reported in vivo decreases in neosubstrates like SALL4, as well as provided evidence of neosubstrate changes for proteins only examined in vitro previously. While there were many proteins that were similarly decreased by all three IMiDs, no compound had the exact same neosubstrate degradation profile as another. We compared our data to previous literature reports of IMiD-induced degradation and known developmental biology associations. Based on our observations, we recommend monitoring at least a major subset of these neosubstrates in a developmental test system to improve CRBN-binding compound-specific risk assessment. A strength of our assay is that it is configurable, and the target list can be readily adapted to focus on only a subset of proteins of interest or expanded to incorporate new findings as additional information about CRBN biology is discovered.


Asunto(s)
Proteolisis , Proteómica , Talidomida , Ubiquitina-Proteína Ligasas , Animales , Conejos , Proteómica/métodos , Ubiquitina-Proteína Ligasas/metabolismo , Talidomida/análogos & derivados , Talidomida/farmacología , Proteolisis/efectos de los fármacos , Femenino , Embrión de Mamíferos/metabolismo , Embrión de Mamíferos/efectos de los fármacos , Proteínas Adaptadoras Transductoras de Señales/metabolismo , Lenalidomida/farmacología , Embarazo
2.
Mol Cell Proteomics ; 23(3): 100733, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38342410

RESUMEN

Nitrotyrosine, or 3-nitrotyrosine, is an oxidative post-translational modification induced by reactive nitrogen species. Although nitrotyrosine is considered a marker of oxidative stress and has been associated with inflammation, neurodegeneration, cardiovascular disease, and cancer, identification of nitrotyrosine-modified proteins remains challenging owing to its low stoichiometric levels in biological samples. To facilitate a comprehensive analysis of proteins and peptides containing nitrotyrosine, we optimized an immunoprecipitation-based enrichment workflow using a cell line model. The identification of proteins and peptides containing nitrotyrosine residues was carried out after peroxynitrite treatment of cell lysates, which generated modified nitrotyrosine residues on susceptible sites on proteins. We evaluated the efficacy of enriching nitrotyrosine-modified proteins and peptides by employing four different commercially available monoclonal antibodies directed against nitrotyrosine. LC-MS/MS analysis resulted in the identification of 1377 and 1624 nitrotyrosine-containing peptides from protein- and peptide-based enrichment experiments, respectively. Although the yield of nitrotyrosine-containing peptides was higher in experiments where peptides rather than proteins were enriched, we found a substantial proportion (37-65%) of identified nitrotyrosine-containing peptides contained nitrotyrosine at the N-terminus. However, in protein-based immunoprecipitation <9% of nitrotyrosine-containing peptides had nitrotyrosine modification at the N-terminus of the peptide. Overall, our study resulted in the identification of 2603 nitrotyrosine-containing peptides of which >2000 have not previously been reported. We synthesized 101 novel nitrotyrosine-containing peptides identified in our analysis and analyzed them by LC-MS/MS to validate our findings. We have confirmed the validity of 70% of these peptides, as they demonstrated a similarity score exceeding 0.7 when compared to peptides identified through experimental methods. Finally, we also validated the presence of nitrotyrosine modification on PKM and EF2 proteins in peroxynitrite-treated samples by immunoblot analysis. The large catalog presented in this study along with the workflow should facilitate the investigation of nitrotyrosine as an oxidative modification in a variety of settings in greater detail.


Asunto(s)
Ácido Peroxinitroso , Espectrometría de Masas en Tándem , Tirosina/análogos & derivados , Cromatografía Liquida/métodos , Proteínas/química , Péptidos/química , Tirosina/metabolismo , Anticuerpos
3.
Mol Cell Proteomics ; 22(9): 100621, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37478973

RESUMEN

Targeted mass spectrometry (MS)-based proteomic assays, such as multiplexed multiple reaction monitoring (MRM)-MS assays, enable sensitive and specific quantification of proteotypic peptides as stoichiometric surrogates for proteins. Efforts are underway to expand the use of MRM-MS assays in clinical environments, which requires a reliable strategy to monitor proteolytic digestion efficiency within individual samples. Towards this goal, extended stable isotope-labeled standard (SIS) peptides (hE), which incorporate native proteolytic cleavage sites, can be spiked into protein lysates prior to proteolytic (trypsin) digestion, and release of the tryptic SIS peptide (hT) can be monitored. However, hT measurements alone cannot monitor the extent of digestion and may be confounded by matrix effects specific to individual patient samples; therefore, they are not sufficient to monitor sample-to-sample digestion variability. We hypothesized that measuring undigested hE, along with its paired hT, would improve detection of digestion issues compared to only measuring hT. We tested the ratio of the SIS pair measurements, or hE/hT, as a quality control (QC) metric of trypsin digestion for two MRM assays: a direct-MRM (398 targets) and an immuno-MRM (126 targets requiring immunoaffinity peptide enrichment) assay, with extended SIS peptides observable for 54% (216) and 62% (78) of the targets, respectively. We evaluated the quantitative bias for each target in a series of experiments that adversely affected proteolytic digestion (e.g., variable digestion times, pH, and temperature). We identified a subset of SIS pairs (36 for the direct-MRM, 7 for the immuno-MRM assay) for which the hE/hT ratio reliably detected inefficient digestion that resulted in decreased assay sensitivity and unreliable endogenous quantification. The hE/hT ratio was more responsive to a decrease in digestion efficiency than a metric based on hT measurements alone. For clinical-grade MRM-MS assays, this study describes a ready-to-use QC panel and also provides a road map for designing custom QC panels.


Asunto(s)
Péptidos , Proteómica , Humanos , Proteómica/métodos , Tripsina/química , Péptidos/análisis , Espectrometría de Masas/métodos , Control de Calidad , Digestión
4.
J Proteome Res ; 23(1): 386-396, 2024 01 05.
Artículo en Inglés | MEDLINE | ID: mdl-38113368

RESUMEN

Extracellular vesicle (EV) secretion has been observed in many types of both normal and tumor cells. EVs contain a variety of distinctive cargoes, allowing tumor-derived serum proteins in EVs to act as a minimally invasive method for clinical monitoring. We have undertaken a comprehensive study of the protein content of the EVs from several cancer cell lines using direct data-independent analysis. Several thousand proteins were detected, including many classic EV markers such as CD9, CD81, CD63, TSG101, and Syndecan-1, among others. We detected many distinctive cancer-specific proteins, including several known markers used in cancer detection and monitoring. We further studied the protein content of EVs from patient serum for both normal controls and pancreatic cancer and hepatocellular carcinoma. The EVs for these studies have been isolated by various methods for comparison, including ultracentrifugation and CD9 immunoaffinity column. Typically, 500-1000 proteins were identified, where most of them overlapped with the EV proteins identified from the cell lines studied. We were able to identify many of the cell-line EV protein markers in the serum EVs, in addition to the large numbers of proteins specific to pancreatic and HCC cancers.


Asunto(s)
Carcinoma Hepatocelular , Vesículas Extracelulares , Neoplasias Hepáticas , Humanos , Proteoma/genética , Proteoma/metabolismo , Carcinoma Hepatocelular/metabolismo , Neoplasias Hepáticas/metabolismo , Vesículas Extracelulares/metabolismo , Biomarcadores/metabolismo , Línea Celular Tumoral
5.
J Proteome Res ; 23(6): 2013-2027, 2024 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-38739617

RESUMEN

The human relaxins belong to the Insulin/IGF/Relaxin superfamily of peptide hormones, and their physiological function is primarily associated with reproduction. In this study, we focused on a prostate tissue-specific relaxin RLN1 (REL1_HUMAN protein) and a broader tissue specificity RLN2 (REL2_HUMAN protein). Due to their structural similarity, REL1 and REL2 proteins were collectively named a 'human relaxin protein' in previous studies and were exclusively measured by immunoassays. We hypothesized that the highly selective and sensitive immunoaffinity-selected reaction monitoring (IA-SRM) assays would reveal the identity and abundance of the endogenous REL1 and REL2 in biological samples and facilitate the evaluation of these proteins for diagnostic applications. High levels of RLN1 and RLN2 transcripts were found in prostate and breast cancer cell lines by RT-PCR. However, no endogenous prorelaxin-1 or mature REL1 were detected by IA-SRM in cell lines, seminal plasma, or blood serum. The IA-SRM assay of REL2 demonstrated its undetectable levels (<9.4 pg/mL) in healthy control female and male sera and relatively high levels of REL2 in maternal sera across different gestational weeks (median 331 pg/mL; N = 120). IA-SRM assays uncovered potential cross-reactivity and nonspecific binding for relaxin immunoassays. The developed IA-SRM assays will facilitate the investigation of the physiological and pathological roles of REL1 and REL2 proteins.


Asunto(s)
Relaxina , Humanos , Relaxina/metabolismo , Relaxina/genética , Masculino , Femenino , Línea Celular Tumoral , Inmunoensayo/métodos , Espectrometría de Masas/métodos , Neoplasias de la Próstata/metabolismo , Neoplasias de la Próstata/genética , Neoplasias de la Próstata/diagnóstico , Semen/química , Semen/metabolismo
6.
Clin Chem Lab Med ; 62(6): 1206-1216, 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38253336

RESUMEN

OBJECTIVES: Many reverse transcription polymerase chain reaction (RT-PCR) methods exist that can detect SARS-CoV-2 RNA in different matrices. RT-PCR is highly sensitive, although viral RNA may be detected long after active infection has taken place. SARS-CoV-2 proteins have shorter detection windows hence their detection might be more meaningful. Given salivary droplets represent a main source of transmission, we explored the detection of viral RNA and protein using four different detection platforms including SISCAPA peptide immunoaffinity liquid chromatography-mass spectrometry (SISCAPA-LC-MS) using polyclonal capture antibodies. METHODS: The SISCAPA-LC MS method was compared to RT-PCR, RT-loop-mediated isothermal amplification (RT-LAMP), and a lateral flow rapid antigen test (RAT) for the detection of virus material in the drool saliva of 102 patients hospitalised after infection with SARS-CoV-2. Cycle thresholds (Ct) of RT-PCR (E gene) were compared to RT-LAMP time-to-positive (TTP) (NE and Orf1a genes), RAT optical densitometry measurements (test line/control line ratio) and to SISCAPA-LC-MS for measurements of viral protein. RESULTS: SISCAPA-LC-MS showed low sensitivity (37.7 %) but high specificity (89.8 %). RAT showed lower sensitivity (24.5 %) and high specificity (100 %). RT-LAMP had high sensitivity (83.0 %) and specificity (100.0 %). At high initial viral RNA loads (<20 Ct), results obtained using SISCAPA-LC-MS correlated with RT-PCR (R2 0.57, p-value 0.002). CONCLUSIONS: Detection of SARS-CoV-2 nucleoprotein in saliva was less frequent than the detection of viral RNA. The SISCAPA-LC-MS method allowed processing of multiple samples in <150 min and was scalable, enabling high throughput.


Asunto(s)
COVID-19 , Espectrometría de Masas , Técnicas de Diagnóstico Molecular , ARN Viral , SARS-CoV-2 , Saliva , Humanos , Saliva/virología , Saliva/química , SARS-CoV-2/aislamiento & purificación , SARS-CoV-2/inmunología , SARS-CoV-2/genética , COVID-19/diagnóstico , COVID-19/virología , ARN Viral/análisis , Espectrometría de Masas/métodos , Técnicas de Amplificación de Ácido Nucleico/métodos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , Masculino , Sensibilidad y Especificidad , Femenino , Persona de Mediana Edad , Fosfoproteínas/análisis , Fosfoproteínas/inmunología , Proteínas de la Nucleocápside de Coronavirus/análisis , Proteínas de la Nucleocápside de Coronavirus/inmunología , Antígenos Virales/análisis , Antígenos Virales/inmunología , Adulto , Cromatografía Liquida/métodos
7.
Clin Chem Lab Med ; 62(4): 720-728, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-37886827

RESUMEN

OBJECTIVES: Numerous studies have proven the potential of cytokeratin 19 fragment 21-1 (CYFRA 21-1) detection in the (early) diagnosis and treatment monitoring of non-small cell lung cancer (NSCLC). Conventional immunoassays for CYFRA 21-1 quantification are however prone to interferences and lack diagnostic sensitivity and standardization. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is an emerging approach based on a different, often superior, detection principle, which may improve the clinical applicability of CYFRA 21-1 in cancer diagnostics. Therefore, we developed and validated a protein precipitation, immunoaffinity (IA) LC-MS/MS assay for quantitative analysis of serum CYFRA 21-1. METHODS: Selective sample preparation was performed using ammonium sulfate (AS) precipitation, IA purification, tryptic digestion and LC-MS/MS quantification using a signature peptide and isotopically labeled internal standard. The workflow was optimized and validated according to EMA guidelines and results were compared to a conventional immunoassay. RESULTS: Significant interference effects were seen during IA purification, which were sufficiently solved by performing AS precipitation prior to IA purification. A linear calibration curve was obtained in the range of 1.0-100 ng/mL (R2=0.98). Accuracy and precision were well within acceptance criteria. In sera of patients suspected of lung cancer, the method showed good correlation with the immunoassay. CONCLUSIONS: A robust AS precipitation-IA LC-MS/MS assay for the quantification of serum CYFRA 21-1 was developed. With this assay, the clinically added value of LC-MS/MS-based detection over immunoassays can be further explored.


Asunto(s)
Antígenos de Neoplasias , Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Humanos , Cromatografía Liquida/métodos , Queratina-19 , Espectrometría de Masas en Tándem/métodos , Neoplasias Pulmonares/diagnóstico , Biomarcadores de Tumor , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico , Cromatografía Líquida con Espectrometría de Masas
8.
Sensors (Basel) ; 24(16)2024 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-39205093

RESUMEN

Exosomes are small extracellular vesicles produced by almost all cell types in the human body, and exosomal microRNAs (miRNAs) are small non-coding RNA molecules that are known to serve as important biomarkers for diseases such as cancer. Given that the upregulation of miR-106b is closely associated with several types of malignancies, the sensitive and accurate detection of miR-106b is important but difficult. In this study, a surface acoustic wave (SAW) biosensor was developed to detect miR-106b isolated from cancer cells based on immunoaffinity separation technique using our unique paddle screw device. Our novel SAW biosensor could detect a miR-106b concentration as low as 0.0034 pM in a linear range from 0.1 pM to 1.0 µM with a correlation coefficient of 0.997. Additionally, we were able to successfully detect miR-106b in total RNA extracted from the exosomes isolated from the MCF-7 cancer cell line, a model system for human breast cancer, with performance comparable to commercial RT-qPCR methods. Therefore, the exosome isolation by the paddle screw method and the miRNA detection using the SAW biosensor has the potential to be used in basic biological research and clinical diagnosis as an alternative to RT-qPCR.


Asunto(s)
Técnicas Biosensibles , Exosomas , MicroARNs , Humanos , Exosomas/química , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación , MicroARNs/aislamiento & purificación , MicroARNs/genética , Células MCF-7 , Anticuerpos/inmunología , Anticuerpos/química
9.
Int J Mol Sci ; 25(15)2024 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-39125575

RESUMEN

Urine, a common source of biological markers in biomedical research and clinical diagnosis, has recently generated a new wave of interest. It has recently become a focus of study due to the presence of its content of extracellular vesicles (EVs). These uEVs have been found to reflect physiological and pathological conditions in kidney, urothelial, and prostate tissue and can illustrate further molecular processes, leading to a rapid expansion of research in this field In this work, we present the advantages of an immunoaffinity-based method for uEVs' isolation with respect to the gold standard purification approach performed by differential ultracentrifugation [in terms of purity and antigen presence. The immunoaffinity method was made feasible by combining specific antibodies with a functionalized polymethacrylate polymer. Flow cytometry indicated a significant fluorescence shift, validating the presence of the markers (CD9, CD63, CD81) and confirming the effectiveness of the isolation method. Microscopy evaluations have shown that the morphology of the vesicles remained intact and corresponded to the expected shapes and dimensions of uEVs. The described protocol is inexpensive, fast, easy to process, has good reproducibility, and can be applied to further biological samples.


Asunto(s)
Biomarcadores , Vesículas Extracelulares , Vesículas Extracelulares/metabolismo , Humanos , Citometría de Flujo/métodos , Masculino , Tetraspanina 30/metabolismo
10.
Clin Proteomics ; 20(1): 20, 2023 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-37170190

RESUMEN

BACKGROUND: Sepsis is a common worldwide health condition with high mortality. It is caused by a dysregulated immune response to the pathogen. Severe infections resulting in sepsis can be also determined by monitoring several bloodstream biomarkers, one of them being pro-hormone procalcitonin (PCT). PCT concentration in the bloodstream correlates well with sepsis and in severe cases increases up to a thousand times from the healthy physiological values in a short time. In this study, we developed a rapid technique for PCT detection by MALDI-TOF mass spectrometry, that uses in-situ enrichment directly on the specialized immuno MALDI chips that are utilized as MALDI plates. The method's ability to detect PCT was confirmed by comparing the results with LC-MS bottom-up workflow. The new method detects intact PCT by its m/z and uncovers its alternations in septic serum. METHODS: The MALDI chips used for the detection of PCT were prepared by ambient ion soft landing of anti-PCT antibody on an ITO glass slide. The chips were used for the development of the rapid MALDI-TOF MS method. A parallel method based on affinity enrichment on magnetic beads followed by LC-MS/MS data-dependent peptide microsequencing was used to prove PCT presence in the sample. All samples were also tested by ELISA to determine PCT concentration prior to analyzing them by mass spectrometry methods. RESULTS: The MALDI chip method was optimized using recombinant PCT spiked into the human serum. The PCT detection limit was 10 ng/mL. The optimized method was used to analyze 13 sera from patients suffering sepsis. The PCT results were confirmed by LC-MS/MS. The measurement of the intact PCT by the MALDI chip method revealed that sera of patients with severe sepsis have other forms of PCT present, which show post-processing of the primary sequence by cleavage of PCT, resulting in the formation of N and C termini fragments. CONCLUSIONS: Procalcitonin from human serum was successfully enriched and detected using immunoaffinity MALDI chips. The intact PCT was characterized in 13 septic patients. The method is more specific compared to non-MS-based immunoaffinity techniques and allows observation of different variants of PCT in septic patients.

11.
Biotechnol Bioeng ; 120(2): 491-502, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36324280

RESUMEN

Haptoglobin (Hp) is a positive acute phase protein, synthesized in the liver, with four N-glycosylation sites carrying mainly complex type N-glycans. Its glycosylation is altered in different types of diseases but still has not been extensively studied mainly due to analytical challenges, especially the lack of a fast, efficient, and robust high-throughput Hp isolation procedure. Here, we describe the development of a high-throughput method for Hp enrichment from human plasma, based on monolithic chromatographic support in immunoaffinity mode and downstream Hp N-glycome analysis by hydrophilic interaction ultrahigh-performance liquid chromatography with fluorescent detection (HILIC-UHPLC-FLR). Chromatographic monolithic supports in a 96-well format enable fast, efficient, and robust Hp enrichment directly from diluted plasma samples. The N-glycome analysis demonstrated that a degree of Hp deglycosylation differs depending on the conditions used for N-glycan release and on the specific glycosylation site, with Asn 241 being the most resistant to deglycosylation under tested conditions. HILIC-UHPLC-FLR analysis enables robust quantification of 28 individual chromatographic peaks, in which N-glycan compositions were determined by UHPLC coupled to electrospray ionization quadrupole time of flight mass spectrometry. The developed analytical approach enables fast evaluation of total Hp N-glycosylation and is applicable in large-scale studies.


Asunto(s)
Haptoglobinas , Espectrometría de Masa por Ionización de Electrospray , Humanos , Cromatografía Liquida , Glicosilación , Polisacáridos/química
12.
Arch Toxicol ; 97(3): 769-785, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36481916

RESUMEN

Drug-induced pancreatic injury (DIPI) is an issue seen in drug development both in nonclinical and clinical contexts. DIPI is typically monitored by measurement of lipase and/or amylase, however, both enzymes lack sensitivity and specificity. Although candidate protein biomarkers specific to pancreas exist, antibody-based assay development is difficult due to their small size or the rapid cleavage by proteolytic enzymes released during pancreatic injury. Here we report the development of a novel multiplexed immunoaffinity-based liquid chromatography mass spectrometric assay (IA-LC-MS/MS) for trypsinogen activation peptide (TAP) and carboxypeptidases A1 and A2 (CPA1, CPA2). This method is based on the enzymatic digestion of the target proteins, immunoprecipitation of the peptides with specific antibodies and LC-MS/MS analysis. This assay was used to detect TAP, CPA1, and CPA2 in 470 plasma samples collected from 9 in-vivo rat studies with pancreatic injury and 8 specificity studies with injury in other organs to assess their performance in monitoring exocrine pancreas injury. The TAP, CPA1, and CPA2 response was compared to histopathology, lipase, amylase and microRNA217. In summary, TAP, CPA1, and CPA2 proteins measured in rat plasma were sensitive and specific biomarkers for monitoring drug-induced pancreatic injury; outperforming lipase and amylase both by higher sensitivity of detection and by sustained increases in plasma observed over a longer time period. These protein-based assays and potentially others under development, are valuable tools for use in nonclinical drug development and as future translatable biomarkers for assessment in clinical settings to further improve patient safety.


Asunto(s)
Amilasas , Espectrometría de Masas en Tándem , Ratas , Animales , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Carboxipeptidasas A/metabolismo , Biomarcadores , Lipasa
13.
Mikrochim Acta ; 190(3): 95, 2023 02 18.
Artículo en Inglés | MEDLINE | ID: mdl-36808576

RESUMEN

In this paper, we report on the utilization of micro-technology based tools to fight viral infections. Inspired by various hemoperfusion and immune-affinity capture systems, a blood virus depletion device has been developed that offers highly efficient capture and removal of the targeted virus from the circulation, thus decreasing virus load. Single-domain antibodies against the Wuhan (VHH-72) virus strain produced by recombinant DNA technology were immobilized on the surface of glass micro-beads, which were then utilized as stationary phase. For feasibility testing, the virus suspension was flown through the prototype immune-affinity device that captured the viruses and the filtered media left the column. The feasibility test of the proposed technology was performed in a Biosafety Level 4 classified laboratory using the Wuhan SARS-CoV-2 strain. The laboratory scale device actually captured 120,000 virus particles from the culture media circulation proving the feasibility of the suggested technology. This performance has an estimated capture ability of 15 million virus particles by using the therapeutic size column design, representing three times over-engineering with the assumption of 5 million genomic virus copies in an average viremic patient. Our results suggested that this new therapeutic virus capture device could significantly lower virus load thus preventing the development of more severe COVID-19 cases and consequently reducing mortality rate.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , Estudios de Factibilidad , Pandemias , Microesferas
14.
Mikrochim Acta ; 190(6): 216, 2023 05 13.
Artículo en Inglés | MEDLINE | ID: mdl-37173548

RESUMEN

Magnetic nanomaterials are widely used, but co-adsorption of impurities will lead to saturation. In this study, the aim was to prepare a magnetic nano-immunosorbent material based on orienting immobilization that can purify and separate 25-hydroxyvitamin D (25OHD) from serum and provides a new concept of sample pretreatment technology. Streptococcus protein G (SPG) was modified on the surface of the chitosan magnetic material, and the antibody was oriented immobilized using the ability of SPG to specifically bind to the Fc region of the monoclonal antibody. The antigen-binding domain was fully exposed and made up for the deficiency of the antibody random immobilization. Compared with the antibody in the random binding format, this oriented immobilization strategy can increase the effective activity of the antibody, and the amount of antibody consumed is saved to a quarter of the former. The new method is simple, rapid, and sensitive, without consuming a lot of organic reagents, and can enrich 25OHD after simple protein precipitation. Combining with liquid chromatography-tandem mass spectrometry (LC-MS/MS), the analysis can be completed in less than 30 min. For 25OHD2 and 25OHD3, the LOD was 0.021 and 0.017 ng mL-1, respectively, and the LOQ was 0.070 and 0.058 ng mL-1, respectively. The results indicated that the magnetic nanomaterials based on oriented immobilization can be applied as an effective, sensitive, and attractive adsorbent to the enrichment of serum 25OHD.


Asunto(s)
Calcifediol , Espectrometría de Masas en Tándem , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Anticuerpos Monoclonales , Fenómenos Magnéticos
15.
Int J Mol Sci ; 24(12)2023 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-37373206

RESUMEN

For targeted protein panels, the ability to specifically assay post-translational modifications (PTMs) in a quantitative, sensitive, and straightforward manner would substantially advance biological and pharmacological studies. The present study highlights the effectiveness of the Affi-BAMS™ epitope-directed affinity bead capture/MALDI MS platform for quantitatively defining complex PTM marks of H3 and H4 histones. Using H3 and H4 histone peptides and isotopically labelled derivatives, this affinity bead and MALDI MS platform achieves a range of >3 orders of magnitude with a technical precision CV of <5%. Using nuclear cellular lysates, Affi-BAMS PTM-peptide capture resolves heterogeneous histone N-terminal PTMs with as little as 100 µg of starting material. In an HDAC inhibitor and MCF7 cell line model, the ability to monitor dynamic histone H3 acetylation and methylation events is further demonstrated (including SILAC quantification). Affi-BAMS (and its capacity for the multiplexing of samples and target PTM-proteins) thus provides a uniquely efficient and effective approach for analyzing dynamic epigenetic histone marks, which is critical for the regulation of chromatin structure and gene expression.


Asunto(s)
Histonas , Proteómica , Histonas/metabolismo , Espectrometría de Masas en Tándem , Procesamiento Proteico-Postraduccional , Código de Histonas , Péptidos/metabolismo , Acetilación
16.
Int J Mol Sci ; 24(2)2023 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-36674508

RESUMEN

The purpose of the present review is to try to highlight recent advances in the application of microfluidic technology on non-invasive prenatal diagnosis (NIPD). The immunoaffinity based microfluidic technology is the most common approach for NIPD, followed by size-based microfluidic methods. Immunoaffinity microfluidic methods can enrich and isolate circulating fetal extravillous trophoblasts (fEVTs) or fetal nucleated red blood cells (fnRBCs) for NIPD by using specific antibodies, but size-based microfluidic systems are only applied to isolate fEVTs. Most studies based on the immunoaffinity microfluidic system gave good results. Enough fetal cells were obtained for chromosomal and/or genetic analysis in all blood samples. However, the results from studies using size-based microfluidic systems for NIPD are less than ideal. In conclusion, recent advances in microfluidic devices make the immunoaffinity based microfluidic system potentially a powerful tool for cell-based NIPD. However, more clinical validation is needed.


Asunto(s)
Microfluídica , Diagnóstico Prenatal , Embarazo , Femenino , Humanos , Diagnóstico Prenatal/métodos , Feto , Dispositivos Laboratorio en un Chip , Anticuerpos
17.
Prep Biochem Biotechnol ; 53(6): 672-682, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36244016

RESUMEN

Lipopolysaccharide (LPS), as a stubborn contamination, should be monitored and kept in an acceptable level during the pharmaceutical production process. Recombinant hepatitis B surface antigen (r-HBsAg) is one of the recombinant biological products, which is probable to suffer from extrinsic endotoxin due to its long and complex production process. This research aims to assess the potential interaction between LPS and r-HBsAg by recruiting immunoaffinity chromatography (IAC) as a novel tool to quantify the interaction. Molecular modeling was performed on the HBsAg molecule to theoretically predict its potential binding and interaction sites. Then dynamic light scattering (DLS) analysis was implemented on HBsAg, LPS, and mixtures of them to reveal the interaction. The virus-like particle (VLP) structure of HBsAg and the ribbon-like structure of LPS were visualized by transmission electron microscopy (TEM). Finally, the interaction was quantified by applying various LPS/HBsAg ratios ranging from 1.67 to 120 EU/dose in the IAC. Consequently, the LPS/HBsAg ratios in the eluate were measured from 1.67 to a maximum of 92.5 EU/dose. The results indicated that 77 to 100% of total LPS interacted with HBsAg by an inverse relationship to the incubated LPS concentration. The findings implied that the introduced procedure is remarkably practical in the quantification of LPS interaction with a target recombinant protein.


Asunto(s)
Cromatografía de Afinidad , Antígenos de Superficie de la Hepatitis B , Lipopolisacáridos , Proteínas Recombinantes , Lipopolisacáridos/análisis , Proteínas Recombinantes/aislamiento & purificación , Proteínas Recombinantes/ultraestructura , Antígenos de Superficie de la Hepatitis B/química , Antígenos de Superficie de la Hepatitis B/genética , Antígenos de Superficie de la Hepatitis B/aislamiento & purificación , Antígenos de Superficie de la Hepatitis B/ultraestructura , Microscopía Electrónica de Transmisión , Vacunas contra Hepatitis B/química , Vacunas contra Hepatitis B/genética , Vacunas contra Hepatitis B/aislamiento & purificación , Modelos Químicos , Secuencia de Aminoácidos , Dispersión Dinámica de Luz , Cromatografía de Afinidad/métodos
18.
J Proteome Res ; 21(2): 547-556, 2022 02 04.
Artículo en Inglés | MEDLINE | ID: mdl-34968056

RESUMEN

We addressed here the need for improved sensitivity of top-down mass spectrometry for identification, differentiation, and absolute quantification of sequence variants of SEA, a bacterial toxin produced by Staphylococcus aureus and regularly involved in food poisoning outbreaks (FPO). We combined immunoaffinity enrichment, a protein internal standard, and optimized acquisition conditions, either by full-scan high-resolution mass spectrometry (HRMS) or multiplex parallel reaction monitoring (PRM) mode. Deconvolution of full-scan HRMS signal and PRM detection of variant-specific fragment ions allowed confident identification of each SEA variant. Summing the PRM signal of variant-common fragment ions was most efficient for absolute quantification, illustrated by a sensitivity down to 2.5 ng/mL and an assay variability below 15%. Additionally, we showed that relative PRM fragment ion abundances constituted a supplementary specificity criterion in top-down quantification. The top-down method was successfully evaluated on a panel of enterotoxin-producing strains isolated during FPO, in parallel to the conventional whole genome sequencing, ELISA, and bottom-up mass spectrometry methods. Top-down provided at the same time correct identification of the SEA variants produced and precise determination of the toxin level. The raw files generated in this study can be found on PASSEL (Peptide Atlas) under data set identifier PASS01710.


Asunto(s)
Enterotoxinas , Microbiología de Alimentos , Enterotoxinas/análisis , Enterotoxinas/genética , Enterotoxinas/metabolismo , Espectrometría de Masas/métodos , Staphylococcus aureus/metabolismo
19.
Mol Cell Proteomics ; 19(8): 1303-1309, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32424026

RESUMEN

MERS is a life-threatening disease and MERS-CoV has the potential to cause the next pandemic. Protein acetylation is known to play a crucial role in host response to viral infection. Acetylation of viral proteins encoded by other RNA viruses have been reported to affect viral replication. It is therefore of interest to see whether MERS-CoV proteins are also acetylated. Viral proteins obtained from infected cells were trypsin-digested into peptides. Acetylated peptides were enriched by immunoprecipitation and subject to nano-LC-Orbitrap analysis. Bioinformatic analysis was performed to assess the conservation level of identified acetylation sites and to predict the upstream regulatory factors. A total of 12 acetylation sites were identified from 7 peptides, which all belong to the replicase polyprotein pp1ab. All identified acetylation sites were found to be highly conserved across MERS-CoV sequences in NCBI database. Upstream factors, including deacetylases of the SIRT1 and HDAC families as well as acetyltransferases of the TIP60 family, were predicted to be responsible for regulating the acetylation events identified. Western blotting confirms that acetylation events indeed occur on pp1ab protein by expressing NSP4 in HEK293 cells. Acetylation events on MERS-CoV viral protein pp1ab were identified for the first time, which indicate that MERS-CoV might use the host acetylation machinery to regulate its enzyme activity and to achieve optimal replication. Upstream factors were predicted, which might facilitate further analysis of the regulatory mechanism of MERS-CoV replication.


Asunto(s)
Lisina/metabolismo , Coronavirus del Síndrome Respiratorio de Oriente Medio/metabolismo , Proteínas Virales/metabolismo , Acetilación , Células HEK293 , Humanos
20.
Mol Cell Proteomics ; 19(7): 1193-1208, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32345711

RESUMEN

The cyclic GMP-AMP synthase (cGAS) protein is a pattern-recognition receptor of the mammalian innate immune system that is recognized as a main cytosolic sensor of pathogenic or damaged DNA. cGAS DNA binding initiates catalytic production of the second messenger, cyclic GMP-AMP, which activates the STING-TBK1-IRF3 signaling axis to induce cytokine expression. Post-translational modification (PTM) has started to be recognized as a critical component of cGAS regulation, yet the extent of these modifications remains unclear. Here, we report the identification and functional analysis of cGAS phosphorylations and acetylations in several cell types under basal and immune-stimulated conditions. cGAS was enriched by immunoaffinity purification from human primary fibroblasts prior to and after infection with herpes simplex virus type 1 (HSV-1), as well as from immune-stimulated STING-HEK293T cells. Six phosphorylations and eight acetylations were detected, of which eight PTMs were not previously documented. PTMs were validated by parallel reaction monitoring (PRM) mass spectrometry in fibroblasts, HEK293T cells, and THP-1 macrophage-like cells. Primary sequence and structural analysis of cGAS highlighted a subset of PTM sites with elevated surface accessibility and high evolutionary sequence conservation. To assess the functional relevance of each PTM, we generated a series of single-point cGAS mutations. Stable cell lines were constructed to express cGAS with amino acid substitutions that prevented phosphorylation (Ser-to-Ala) and acetylation (Lys-to-Arg) or that mimicked the modification state (Ser-to-Asp and Lys-to-Gln). cGAS-dependent apoptotic and immune signaling activities were then assessed for each mutation. Our results show that acetyl-mimic mutations at Lys384 and Lys414 inhibit the ability of cGAS to induce apoptosis. In contrast, the Lys198 acetyl-mimic mutation increased cGAS-dependent interferon signaling when compared with the unmodified charge-mimic. Moreover, targeted PRM quantification showed that Lys198 acetylation is decreased upon infections with two herpesviruses-HSV-1 and human cytomegalovirus (HCMV), highlighting this residue as a regulatory point during virus infection.


Asunto(s)
Apoptosis/genética , Nucleotidiltransferasas/química , Nucleotidiltransferasas/metabolismo , Procesamiento Proteico-Postraduccional , Acetilación , Cromatografía Liquida , Infecciones por Citomegalovirus/inmunología , Infecciones por Citomegalovirus/metabolismo , Fibroblastos , Células HEK293 , Infecciones por Herpesviridae/inmunología , Infecciones por Herpesviridae/metabolismo , Interacciones Microbiota-Huesped/inmunología , Humanos , Inmunidad Innata , Interferón beta/metabolismo , Mutación , Nucleotidiltransferasas/genética , Fosforilación , Transducción de Señal/genética , Transducción de Señal/inmunología , Espectrometría de Masas en Tándem
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA