1.
J Orthop Surg Res ; 17(1): 450, 2022 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-36224662

RESUMEN

BACKGROUND: Total knee arthroplasty (TKA) is an established surgical treatment for advanced knee osteoarthritis by which patients can expect improvement of knee pain and function. Although many surgeons have investigated limb alignment after TKA, changes in coronal positional relation between the femur and tibia are not known well. METHODS: Radiographs of 105 knees of young Japanese patients between 20 and 49 years-old (60 men and 45 women) without osteoarthritic changes who received arthroscopic surgeries at our hospital were used in this study. Using 2D-templates of the medial pivot design (the FINE total knee), we simulated TKA on a SYNAPSE-PACS software. First, the femoral component was placed in normal knee alignment and then was merged to the medial concave of the insert where the tibial component was placed in neutral alignment. The length of the mediolateral shift of the femoral component was measured as an estimate of lateral shift of the femoral condyle, of which association with radiographic parameters including the femorotibial angle (FTA), lateral distal femoral angle (LDFA), and medial proximal tibial angle (MPTA) was analyzed. Subjects were classified into three groups according to the femoral component size that was chosen in simulation of TKA, and the lateral shift of the femoral condyle was compared between groups. RESULTS: The estimated mean lateral shift of the femoral condyle was 5.99 ± 1.98 mm and was greater in males than females (p < 0.05). Also, it was most highly correlated with the medial proximal tibial angle (MPTA) (r = - 0.553, p < 0.01). A group receiving larger component sizes significantly shifted more laterally compared with a group receiving smaller component sizes (p < 0.01). CONCLUSIONS: These results suggest that the coronal positional relation between the femur and tibia is altered and subsequent ligament imbalance may occur after mechanically aligned TKA using the medial pivot design.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Fémur/diagnóstico por imagen , Fémur/cirugía , Japón , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/etiología , Osteoartritis de la Rodilla/cirugía , Rango del Movimiento Articular , Tibia/cirugía
2.
Knee ; 24(2): 434-438, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28189408

RESUMEN

BACKGROUND: The medial pivot total knee prosthesis with alumina ceramic femoral components was introduced to reproduce physiological knee kinematics and reduce polyethylene wear. The five-year clinical outcomes of alumina medial pivot total knee arthroplasties (TKA) have previously been reported. The purpose of this study was to provide the longer-term clinical results at a minimum follow-up of 10years. METHODS: The clinical results of 70 alumina medial pivot TKA in 51 consecutive patients, with a minimum follow-up period of 10years, were evaluated. RESULTS: Mean follow-up was 11.8years (range 10 to 13). Alumina medial pivot TKAs improved the patients' Knee Society knee scores, function scores, and postoperative ranges of motion compared with their pre-operative statuses (P<0.05 for each). Revision surgery was required in one knee due to a postoperative fracture of the tibial plateau after a fall that occurred two years postoperatively. Osteolysis and femoral component loosening was identified in one case after the initial five-year time point of analysis. The survival rate was 99.1% at 10years. CONCLUSIONS: This study demonstrated excellent clinical results for patients receiving the alumina medial pivot prosthesis at a minimum follow-up period of 10years.


Asunto(s)
Artritis/cirugía , Artroplastia de Reemplazo de Rodilla/instrumentación , Prótesis de la Rodilla , Anciano , Anciano de 80 o más Años , Óxido de Aluminio , Materiales Biocompatibles , Cerámica , Fémur/cirugía , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/cirugía , Persona de Mediana Edad , Polietileno , Diseño de Prótesis , Reoperación , Tibia/cirugía
3.
Ann Transl Med ; 4(1): 6, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26855942

RESUMEN

Total knee arthroplasty (TKA) with a medial pivot design was developed in order to mimic normal knee kinematics; the highly congruent medial compartment implant should improve clinical results and decrease contact stresses. Clinical and radiographic mid-term outcomes are satisfactory, but we need other studies to evaluate long-term results and indications for unusual cases.

4.
Bone Joint J ; 98-B(8): 1050-5, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27482016

RESUMEN

AIMS: The Advance Medial-Pivot total knee arthroplasty (TKA) was designed to reflect contemporary data regarding the kinematics of the knee. We wished to examine the long-term results obtained with this prosthesis by extending a previous evaluation. PATIENTS AND METHODS: We retrospectively evaluated prospectively collected data from 225 consecutive patients (41 men and 184 women; mean age at surgery 71 years, 52 to 84) who underwent 284 TKAs with a mean follow-up of 13.4 years (11 to 15). Implant failure, complication rate, clinical (both subjective and objective) and radiological outcome were assessed. Pre- and post-operative clinical and radiographic data were available at regular intervals for all patients. A total of ten patients (4.4%; ten TKAs) were lost to follow-up. RESULTS: Survival analysis at 15 years showed a cumulative success rate of 97.3% (95% confidence interval (CI) 96.7 to 97.9) for revision for any reason, of 96.4% (95% CI 95.2 to 97.6) for all operations, and 98.8% (95% CI 98.2 to 99.4) for aseptic loosening as an end point. Three TKAs (1.06%) were revised due to aseptic loosening, two (0.7%) due to infection, one (0.35%) due to instability and one (0.35%) due to a traumatic dislocation. All patients showed a statistically significant improvement on the Knee Society Score (p = 0.001), Western Ontario and McMaster University Osteoarthritis Index (p = 0.001), Short Form-12 (p = 0.01), and Oxford Knee Score (p = 0.01). A total of 207 patients (92%) were able to perform age appropriate activities with a mean flexion of the knee of 117° (85° to 135°) at final follow-up. CONCLUSION: This study demonstrates satisfactory functional and radiographic long-term results for this implant. Cite this article: Bone Joint J 2016;98-B:1050-5.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Prótesis de la Rodilla , Osteoartritis de la Cadera/cirugía , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/efectos adversos , Femenino , Estudios de Seguimiento , Articulación de la Cadera/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/diagnóstico por imagen , Dolor Postoperatorio/prevención & control , Satisfacción del Paciente , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis/efectos adversos , Infecciones Relacionadas con Prótesis/etiología , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA