1.
Sensors (Basel) ; 23(13)2023 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-37447789

RESUMEN

The doubly clamped microelectromechanical system (MEMS) beam resonators exhibit extremely high sensitivity to tiny changes in the resonance frequency owing to their high quality (Q-) factors, even at room temperature. Such a sensitive frequency-shift scheme is very attractive for fast and highly sensitive terahertz (THz) detection. The MEMS resonator absorbs THz radiation and induces a temperature rise, leading to a shift in its resonance frequency. This frequency shift is proportional to the amount of THz radiation absorbed by the resonator and can be detected and quantified, thereby allowing the THz radiation to be measured. In this review, we present an overview of the THz bolometer based on the doubly clamped MEMS beam resonators in the aspects of working principle, readout, detection speed, sensitivity, and attempts at improving the performance. This allows one to have a comprehensive view of such a novel THz detector.


Asunto(s)
Sistemas Microelectromecánicos , Diseño de Equipo , Radiación Terahertz , Temperatura , Vibración
2.
Sensors (Basel) ; 23(4)2023 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-36850551

RESUMEN

This work presents a modular approach to the development of strain sensors for large deformations. The proposed method separates the extension and signal transduction mechanisms using a soft, elastomeric transmission and a high-sensitivity microelectromechanical system (MEMS) transducer. By separating the transmission and transduction, they can be optimized independently for application-specific mechanical and electrical performance. This work investigates the potential of this approach for human health monitoring as an implantable cardiac strain sensor for measuring global longitudinal strain (GLS). The durability of the sensor was evaluated by conducting cyclic loading tests over one million cycles, and the results showed negligible drift. To account for hysteresis and frequency-dependent effects, a lumped-parameter model was developed to represent the viscoelastic behavior of the sensor. Multiple model orders were considered and compared using validation and test data sets that mimic physiologically relevant dynamics. Results support the choice of a second-order model, which reduces error by 73% compared to a linear calibration. In addition, we evaluated the suitability of this sensor for the proposed application by demonstrating its ability to operate on compliant, curved surfaces. The effects of friction and boundary conditions are also empirically assessed and discussed.


Asunto(s)
Electricidad , Tensión Longitudinal Global , Humanos , Calibración , Fricción , Corazón
3.
Sensors (Basel) ; 19(18)2019 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-31540113

RESUMEN

Die attach is a typical process that induces thermal stress in the fabrication of microelectromechanical system (MEMS) devices. One solution to this problem is attaching a portion of the die to the package. In such partial die bonding, the lack of control over the spreading of the adhesive can cause non-uniform attachment. In this case, asymmetric packaging stress could be generated and transferred to the die. The performance of MEMS devices, which employ the differential outputs of the sensing elements, is directly affected by the asymmetric packaging stress. In this paper, we proposed a die-attach structure with a pillar to reduce the asymmetric packaging stress and the changes in packaging stress due to changes in the device temperature. To verify the proposed structure, we fabricated four types of differential resonant accelerometers (DRA) with the silicon-on-glass process. We confirmed experimentally that the pillar can control the spreading of the adhesive and that the asymmetric packaging stress is considerably reduced. The simulation and experimental results indicated that the DRAs manufactured using glass-on-silicon wafers as handle substrates instead of conventional glass wafers have a structure that compensates for the thermal stress.

4.
Sensors (Basel) ; 18(8)2018 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-30096854

RESUMEN

The mechanical stress in silicon-on-glass MEMS structures and a stress isolation scheme were studied by analysis and experimentation. Double-ended tuning forks (DETFs) were used to measure the stress based on the stress-frequency conversion effect. Considering the coefficients of thermal expansion (CTEs) of silicon and glass and the temperature coefficient of the Young's modulus of silicon, the sensitivity of the natural frequency to temperature change was analyzed. A stress isolation mechanism composed of annular isolators and a rigid frame is proposed to prevent the structure inside the frame from being subjected to thermal stresses. DETFs without and with one- or two-stage isolation frames with the orientations <110> and <100> were designed, the stress and natural frequency variations with temperature were simulated and measured. The experimental results show that in the temperature range of -50 °C to 85 °C, the stress varied from -18 MPa to 10 MPa in the orientation <110> and -11 MPa to 5 MPa in the orientation <100>. For the 1-stage isolated DETF of <110> orientation, the measured stress variation was only 0.082 MPa. The thermal stress can be mostly rejected by a stress isolation structure, which is applicable in the design of stress-sensitive MEMS sensors and actuators.

5.
Sensors (Basel) ; 16(12)2016 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-27973429

RESUMEN

This paper presents an algorithm for velocity-aided attitude estimation for helicopter aircraft using a microelectromechanical system inertial-measurement unit. In general, high- performance gyroscopes are used for estimating the attitude of a helicopter, but this type of sensor is very expensive. When designing a cost-effective attitude system, attitude can be estimated by fusing a low cost accelerometer and a gyro, but the disadvantage of this method is its relatively low accuracy. The accelerometer output includes a component that occurs primarily as the aircraft turns, as well as the gravitational acceleration. When estimating attitude, the accelerometer measurement terms other than gravitational ones can be considered as disturbances. Therefore, errors increase in accordance with the flight dynamics. The proposed algorithm is designed for using velocity as an aid for high accuracy at low cost. It effectively eliminates the disturbances of accelerometer measurements using the airspeed. The algorithm was verified using helicopter experimental data. The algorithm performance was confirmed through a comparison with an attitude estimate obtained from an attitude heading reference system based on a high accuracy optic gyro, which was employed as core attitude equipment in the helicopter.

6.
Micromachines (Basel) ; 15(8)2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39203652

RESUMEN

Ultrasound is widely applied in diverse domains, such as medical imaging, non-destructive evaluation, and acoustic communication. Piezoelectric micromachined ultrasonic transducers (PMUTs) capable of generating and receiving ultrasonic signals at the micrometer level have become a prominent technology in the field of ultrasound. It is important to enrich the models of the PMUTs to meet the varied applications. In this study, a series of PMUT devices featured with various top electrode configurations, square, circular, and doughnut, were designed to assess the influence of shape on the emission efficacy. It was demonstrated that the PMUTs with a circular top electrode were outperformed, which was calculated from the external acoustic pressure produced by the PMUTs operating in the fundamental resonant mode at a specified distance. Furthermore, the superior performance of PMUT arrays were exhibited through computational simulations for the circular top electrode geometries. Conventional microelectromechanical systems (MEMS) techniques were used to fabricate an array of PMUTs based on aluminum nitride (AlN) films. These findings make great contributions for enhancing the signal transmission sensitivity and bandwidth of PMUTs, which have significant potential in non-destructive testing and medical imaging applications.

7.
Micromachines (Basel) ; 14(1)2023 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-36677270

RESUMEN

Due to their excellent capabilities to generate and sense ultrasound signals in an efficient and well-controlled way at the microscale, piezoelectric micromechanical ultrasonic transducers (PMUTs) are being widely used in specific systems, such as medical imaging, biometric identification, and acoustic wireless communication systems. The ongoing demand for high-performance and adjustable PMUTs has inspired the idea of manipulating PMUTs by voltage. Here, PMUTs based on AlN thin films protected by a SiO2 layer of 200 nm were fabricated using a standard MEMS process with a resonant frequency of 505.94 kHz, a -6 dB bandwidth (BW) of 6.59 kHz, and an electromechanical coupling coefficient of 0.97%. A modification of 4.08 kHz for the resonant frequency and a bandwidth enlargement of 60.2% could be obtained when a DC bias voltage of -30 to 30 V was applied, corresponding to a maximum resonant frequency sensitivity of 83 Hz/V, which was attributed to the stress on the surface of the piezoelectric film induced by the external DC bias. These findings provide the possibility of receiving ultrasonic signals within a wider frequency range, which will play an important role in underwater three-dimensional imaging and nondestructive testing.

8.
Discov Nano ; 18(1): 25, 2023 02 27.
Artículo en Inglés | MEDLINE | ID: mdl-36847870

RESUMEN

Piezoelectric microelectromechanical system (piezo-MEMS)-based mass sensors including the piezoelectric microcantilevers, surface acoustic waves (SAW), quartz crystal microbalance (QCM), piezoelectric micromachined ultrasonic transducer (PMUT), and film bulk acoustic wave resonators (FBAR) are highlighted as suitable candidates for highly sensitive gas detection application. This paper presents the piezo-MEMS gas sensors' characteristics such as their miniaturized structure, the capability of integration with readout circuit, and fabrication feasibility using multiuser technologies. The development of the piezoelectric MEMS gas sensors is investigated for the application of low-level concentration gas molecules detection. In this work, the various types of gas sensors based on piezoelectricity are investigated extensively including their operating principle, besides their material parameters as well as the critical design parameters, the device structures, and their sensing materials including the polymers, carbon, metal-organic framework, and graphene.

9.
Micromachines (Basel) ; 14(6)2023 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-37374848

RESUMEN

Recent developments in MEMS technologies have made such devices attractive for use in applications that involve precision engineering and scalability. In the biomedical industry, MEMS devices have gained popularity in recent years for use as single-cell manipulation and characterisation tools. A niche application is the mechanical characterisation of single human red blood cells, which may exhibit certain pathological conditions that impart biomarkers of quantifiable magnitude that are potentially detectable via MEMS devices. Such applications come with stringent thermal and structural specifications wherein the potential device candidates must be able to function with no exceptions. This work presents a state-of-the-art numerical modelling methodology that is capable of accurately predicting MEMS device performance in various media, including aqueous ones. The method is strongly coupled in nature, whereby thermal as well as structural degrees of freedom are transferred to and from finite element and finite volume solvers at every iteration. This method therefore provides MEMS design engineers with a reliable tool that can be used in design and development stages and helps to avoid total reliability on experimental testing. The proposed numerical model is validated via a series of physical experiments. Four MEMS electrothermal actuators with cascaded V-shaped drivers are presented. With the use of the newly proposed numerical model as well as the experimental testing, the MEMS devices' suitability for biomedical applications is confirmed.

10.
Micromachines (Basel) ; 11(4)2020 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-32235583

RESUMEN

Large-displacement microelectromechanical system (MEMS) scanners are in high demand for a wide variety of optical applications. Kirigami, a traditional Japanese art of paper cutting and folding, is a promising engineering method for creating out-of-plane structures. This paper explores the feasibility and potential of a kirigami-inspired electrothermal MEMS scanner, which achieves large vertical displacement by out-of-plane film actuation. The proposed scanner is composed of film materials suitable for electrothermal self-reconfigurable folding and unfolding, and microscale film cuttings are strategically placed to generate large displacement. The freestanding electrothermal kirigami film with a 2 mm diameter and high fill factor is completely fabricated by careful stress control in the MEMS process. A 200 µm vertical displacement with 131 mW and a 20 Hz responsive frequency is experimentally demonstrated as a unique function of electrothermal kirigami film. The proposed design, fabrication process, and experimental test validate the proposed scanner's feasibility and potential for large-displacement scanning with a high fill factor.

11.
Micromachines (Basel) ; 11(7)2020 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-32629841

RESUMEN

In this study, we propose a microelectromechanical system (MEMS) force sensor for microflow measurements. The sensor is equipped with a flow sensing piezoresistive cantilever and a dummy piezoresistive cantilever, which acts as a temperature reference. Since the dummy cantilever is also in the form of a thin cantilever, the temperature environment of the dummy sensor is almost identical to that of the sensing cantilever. The temperature compensation effect was measured, and the piezoresistive cantilever was combined with a gasket jig to enable the direct implementation of the piezoresistive cantilever in a flow tube. The sensor device stably measured flow rates from 20 µL/s to 400 µL/s in a silicon tube with a 2-mm inner diameter without being disturbed by temperature fluctuations.

12.
Polymers (Basel) ; 12(5)2020 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-32455993

RESUMEN

In this study, we present a comprehensive review of polymer-based microelectromechanical systems (MEMS) electromagnetic (EM) actuators and their implementation in the biomedical engineering field. The purpose of this review is to provide a comprehensive summary on the latest development of electromagnetically driven microactuators for biomedical application that is focused on the movable structure development made of polymers. The discussion does not only focus on the polymeric material part itself, but also covers the basic mechanism of the mechanical actuation, the state of the art of the membrane development and its application. In this review, a clear description about the scheme used to drive the micro-actuators, the concept of mechanical deformation of the movable magnetic membrane and its interaction with actuator system are described in detail. Some comparisons are made to scrutinize the advantages and disadvantages of electromagnetic MEMS actuator performance. The previous studies and explanations on the technology used to fabricate the polymer-based membrane component of the electromagnetically driven microactuators system are presented. The study on the materials and the synthesis method implemented during the fabrication process for the development of the actuators are also briefly described in this review. Furthermore, potential applications of polymer-based MEMS EM actuators in the biomedical field are also described. It is concluded that much progress has been made in the material development of the actuator. The technology trend has moved from the use of bulk magnetic material to using magnetic polymer composites. The future benefits of these compact flexible material employments will offer a wide range of potential implementation of polymer composites in wearable and portable biomedical device applications.

13.
Micromachines (Basel) ; 11(3)2020 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-32235795

RESUMEN

In this study, a 3D coil embedded in a silicon substrate including densely distributed through-silicon vias (TSVs) was fabricated via a rapid metal powder sintering process. The filling and sintering methods for microdevices were evaluated, and the effects of powder types were compared. The parameters influencing the properties and processing speed were analyzed. The results showed that the pre-alloyed powder exhibited the best uniformity and stability when the experiment used two or more types of powders to avoid the segregation effect. The smaller the particle diameter, the better the inductive performance will be. The entire structure can be sintered near the melting point of the alloy, and increasing the temperature increases strength, while resulting in low resistivity. Finally, an 800-µm-high coil was fabricated. This process does not need surface metallization and seed layer formation. The forming process involves only sintering instead of slowly growing copper with a tiny current. Therefore, this process has advantages, such as a process time of 7 h, corresponding to an 84% reduction compared to current electroplating processes (45 h), and a 543% efficiency improvement. Thus, this process is more efficient, controllable, stable, and suitable for mass production of devices with flexible dimensions.

14.
Biomed Tech (Berl) ; 2020 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-32621727

RESUMEN

The present work proposes a novel, compact, intuitively simple and efficient structure to improve the sensitivity of a microelectromechanical system (MEMS) capacitive accelerometer using an arrangement of microlever as a displacement amplifier. The accelerometer is proposed to serve as a microphone in the fully implantable cochlear prosthetic system which can be surgically implanted at the middle ear bone structure. Therefore, the design parameters such as size, weight and resonant frequency require deliberation. The paper presents a novel analytical model considering the impact of the mechanical amplification along with the width of the microlever and the capacitive fringe effects on the performance of the sensor. The design is simulated and verified using COMSOL MULTIPHYSICS 4.2. The accelerometer is designed within a sensing area of 1 mm2 and accomplishes a nominal capacitance of 4.85 pF and an excellent sensitivity of 5.91 fF/g.

15.
Methods Mol Biol ; 2160: 275-292, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32529444

RESUMEN

Pollen tubes face many obstacles on their way to the ovule. They have to decide whether to navigate around cells or penetrate the cell wall and grow through it or even within it. Besides chemical sensing, which directs the pollen tubes on their path to the ovule, this involves mechanosensing to determine the optimal strategy in specific situations. Mechanical cues then need to be translated into physiological signals, which eventually lead to changes in the growth behavior of the pollen tube. To study these events, we have developed a system to directly quantify the forces involved in pollen tube navigation. We combined a lab-on-a-chip device with a microelectromechanical systems-based force sensor to mimic the pollen tube's journey from stigma to ovary in vitro. A force-sensing plate creates a mechanical obstacle for the pollen tube to either circumvent or attempt to penetrate while measuring the involved forces in real time. The change of growth behavior and intracellular signaling activities can be observed with a fluorescence microscope.


Asunto(s)
Microfluídica/métodos , Tubo Polínico/fisiología , Robótica/métodos , Estrés Mecánico , Arabidopsis , Calcio/metabolismo , Dispositivos Laboratorio en un Chip , Microfluídica/instrumentación , Tubo Polínico/metabolismo , Robótica/instrumentación
16.
J Orthop Res ; 37(9): 1873-1880, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31042313

RESUMEN

Current diagnostic modalities, such as radiographs or computed tomography, exhibit limited ability to predict the outcome of bone fracture healing. Failed fracture healing after orthopaedic surgical treatments are typically treated by secondary surgery; however, the negative correlation of time between primary and secondary surgeries with resultant health outcome and medical cost accumulation drives the need for improved diagnostic tools. This study describes the simultaneous use of multiple (n = 5) implantable flexible substrate wireless microelectromechanical (fsBioMEMS) sensors adhered to an intramedullary nail (IMN) to quantify the biomechanical environment along the length of fracture fixation hardware during simulated healing in ex vivo ovine tibiae. This study further describes the development of an antenna array for interrogation of five fsBioMEMS sensors simultaneously, and quantifies the ability of these sensors to transmit signal through overlaying soft tissues. The ex vivo data indicated significant differences associated with sensor location on the IMN (p < 0.01) and fracture state (p < 0.01). These data indicate that the fsBioMEMS sensor can serve as a tool to diagnose the current state of fracture healing, and further supports the use of the fsBioMEMS as a means to predict fracture healing due to the known existence of latency between changes in fracture site material properties and radiographic changes. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:1873-1880, 2019.


Asunto(s)
Curación de Fractura , Sistemas Microelectromecánicos , Procedimientos Ortopédicos , Humanos , Estrés Mecánico
17.
Micromachines (Basel) ; 10(5)2019 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-31052222

RESUMEN

This paper first presents an adaptive expectation-maximization (AEM) control algorithm based on a measurement-data-driven model to reduce the variance of microelectromechanical system (MEMS) accelerometer sensor under multi disturbances. Significantly different characteristics of the disturbances, consisting of drastic-magnitude, short-duration vibration in the external environment, and slowly-varying, long-duration fluctuation inside the sensor are first constructed together with the measurement model of the accelerometer. Next, through establishing a data-driven model based on a historical small measurement sample, the window length of filter of the presented algorithm is adaptively chosen to estimate the sensor state and identify these disturbances simultaneously. Simulation results of the proposed AEM algorithm based on experimental test are compared with the Kalman filter (KF), least mean square (LMS), and regular EM (REM) methods. Variances of the estimated equivalent input under static condition are 0.212 mV, 0.149 mV, 0.015 mV, and 0.004 mV by the KF, LMS, REM, and AEM, respectively. Under dynamic conditions, the corresponding variances are 35.5 mV, 2.07 mV, 2.0 mV, and 1.45 mV, respectively. The variances under static condition based on the proposed method are reduced to 1.9%, 2.8%, and 27.3%, compared with the KF, LMS, and REM methods, respectively. The corresponding variances under dynamic condition are reduced to 4.1%, 70.1%, and 72.5%, respectively. The effectiveness of the proposed method is verified to reduce the variance of the MEMS resonant accelerometer sensor.

18.
Med Eng Phys ; 55: 60-67, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29576459

RESUMEN

Gyroscopes are now becoming one of the most sold MEMS sensors, given that the many applications that require their use are booming. In the medical field, gyroscopes can be found in Inertial Measurement Units used for the development of clinical tools that are dedicated to human-movement monitoring. However, MEMS gyroscopes are known to suffer from a drift phenomenon, which is mainly due to temperature variations. This drift dramatically affects measurement capability, especially that of cheap MEMs gyroscopes. Calibration is therefore a key factor in achieving accurate measurements. However, traditional calibration procedures are often complex and require costly equipment. This paper therefore proposes an easy protocol for performing a thermal gyroscope calibration. In this protocol, accuracy over the angular velocity is evaluated by referring to an optoelectronic measurement, and is compared with the traditional calibration performed by the manufacturer. The RMSE between the reference angular velocity and that obtained with the proposed calibration was of 0.7°/s, which was slightly smaller than the RMSE of 1.1°/s achieved by the manufacturer's calibration. An analysis of uncertainty propagation shows that offset variability is the major source of error over the computed rate of rotation from the tested sensors, since it accounts for 97% of the error. It can be concluded that the proposed simple calibration method leads to a similar degree of accuracy as that achieved by the manufacturer's procedure.


Asunto(s)
Sistemas Microelectromecánicos , Rotación , Temperatura , Calibración
19.
Micromachines (Basel) ; 9(11)2018 Nov 17.
Artículo en Inglés | MEDLINE | ID: mdl-30453626

RESUMEN

Microelectromechanical system (MEMS) suspended inductors have excellent radio-frequency (RF) performance. The inductance value is one of the main features that characterizes the performance of inductors. It is important to consider the influence of the substrate and the suspension height in calculating the inductance value accurately. In this paper, a method is proposed to calculate the inductance value of the MEMS suspended inductor wire with a silicon substrate, as the wire is the basic component of the inductor coil. Then the method is extended to the suspended inductors consisting of a single turn coil. The calculation results obtained by this proposed method were verified by finite-element analysis (HFSS) and they were found to agree well with the results of the HFSS simulation.

20.
Biomed Tech (Berl) ; 63(6): 699-708, 2018 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-29087950

RESUMEN

The present work attempts to enhance the sensitivity of a folded beam microelectromechanical systems (MEMS) capacitive accelerometer by optimising the device geometry. The accelerometer is intended to serve as a microphone in the fully implantable hearing application which can be surgically implanted in the middle ear bone structure. For the efficient design of the accelerometer as a fully implantable biomedical device, the design parameters such as size, weight and resonant frequency have been considered. The geometrical parameters are varied to obtain the optimum sensitivity considering the design constraints and the stability of the structure. The optimised design is simulated and verified using COMSOL MULTIPHYSICS 4.2. The stability of the device is ensured using eigenfrequency analysis. Optimised results of the device geometry are presented and discussed. The accelerometer has a sensing area of 1 mm2 and attains a nominal capacitance of 5.3 pF and an optimum sensitivity of 6.89 fF.


Asunto(s)
Implantes Cocleares , Sistemas Microelectromecánicos , Acelerometría/instrumentación , Pruebas Auditivas , Humanos , Sistemas Microelectromecánicos/instrumentación , Diseño de Prótesis
SELECCIÓN DE REFERENCIAS