Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 381
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Curr Allergy Asthma Rep ; 24(6): 317-322, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38776041

RESUMEN

PURPOSE OF REVIEW: This review aims to deliver a comprehensive report of the most recent knowledge on diagnosing allergic dermatoses in skin of color (SOC) patients. RECENT FINDINGS: Allergic dermatoses can affect populations of all backgrounds. However, racial/ethnic variations in epidemiology, clinical features, and associated allergens have been reported. Nuances in the approach to diagnosis, including the assessment of erythema and interpretation of patch tests, are important considerations when treating patients with SOC. In this review, we outline various manifestations of allergic dermatoses in SOC with a focus on important clinical presentations and diagnostic tools, aiming to support clinicians in accurate recognition of diseases, thereby opening avenues to improve outcomes across diverse skin types.


Asunto(s)
Hipersensibilidad , Enfermedades de la Piel , Humanos , Alérgenos/inmunología , Hipersensibilidad/diagnóstico , Hipersensibilidad/inmunología , Pruebas del Parche , Piel/patología , Piel/inmunología , Enfermedades de la Piel/diagnóstico , Grupos Raciales
2.
J Am Acad Dermatol ; 90(2): 319-327, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37879460

RESUMEN

BACKGROUND: Isothiazolinones are a common cause of allergic contact dermatitis. OBJECTIVE: To examine the prevalence of positive patch test reactions to isothiazolinones from 2017-2020 and characterize isothiazolinone-allergic (Is+) patients compared with isothiazolinone nonallergic (Is-) patients. METHODS: Retrospective cross-sectional analysis of 9028 patients patch tested to methylchloroisothiazolinone (MCI)/methylisothiazolinone (MI) 0.02% aqueous, MI 0.2% aqueous, benzisothiazolinone (BIT) 0.1% petrolatum, and/or octylisothiazolinone (OIT) 0.025% petrolatum. Prevalence, reaction strength, concurrent reactions, clinical relevance, and source of allergens were tabulated. RESULTS: In total, 21.9% (1976/9028) of patients had a positive reaction to 1 or more isothiazolinones. Positivity to MI was 14.4% (1296/9012), MCI/MI was 10.0% (903/9017), BIT was 8.6% (777/9018), and OIT was 05% (49/9028). Compared with Is-, Is+ patients were more likely to have occupational skin disease (16.5% vs 10.3%, P <.001), primary hand dermatitis (30.2% vs 19.7%, P <.001), and be >40 years (73.1% vs 61.9%, P <.001). Positive patch test reactions to >1 isothiazolinone occurred in 44.1% (871/1976) of Is+ patients. Testing solely to MCI/MI would miss 47.3% (611/1292) of MI and 60.1% (466/776) of BIT allergic reactions. LIMITATIONS: Retrospective cross-sectional study design and lack of follow-up data. CONCLUSION: Sensitization to isothiazolinones is high and concurrent sensitization to multiple isothiazolinone allergens is common.


Asunto(s)
Dermatitis Alérgica por Contacto , Dermatitis Profesional , Tiazoles , Humanos , Estudios Transversales , Estudios Retrospectivos , Dermatitis Alérgica por Contacto/diagnóstico , Dermatitis Alérgica por Contacto/epidemiología , Dermatitis Alérgica por Contacto/etiología , Dermatitis Profesional/diagnóstico , Dermatitis Profesional/epidemiología , Dermatitis Profesional/etiología , Alérgenos/efectos adversos , América del Norte , Pruebas del Parche/efectos adversos , Vaselina , Conservadores Farmacéuticos/efectos adversos
3.
J Am Acad Dermatol ; 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38972480

RESUMEN

BACKGROUND: Patch testing for multiple cross-reactive allergens for allergic contact dermatitis (ACD) may not be necessary because of copositivity. OBJECTIVES: We evaluated the formaldehyde group allergens to determine the optimal, most cost-effective allergens to test. METHODS: A retrospective analysis of Mayo Clinic (1997-2022) examined the well-established copositive formaldehyde group: formaldehyde, quaternium 15, hexahydro-1,3,5-tris(2-hydroxyethyl)triazine, diazolidinyl urea, imidazolidinyl urea, toluenesulphonamide formaldehyde resin, DMDM hydantoin, and ethyleneurea melamine formaldehyde mix. Patch Optimization Platform identified which single formaldehyde-related allergen optimally captures patients with clinically relevant ACD. Next, Patch Optimization Platform determined the optimal additional 1, 2, 3, etc. allergens. Cost per patch test was $5.19 (Medicare 2022). RESULTS: A total of 9832 patients were tested for all listed allergens, with 830 having positive patch test results. Patch Optimization Platform determined that quaternium 15 alone captures 53% of patients with ACD to the formaldehyde group; adding the optimal second allergen (formaldehyde 1%) captures 78%; the optimal 5 top allergens capture >94% of patients. The incremental cost per additional diagnosis increased up to 44-fold as the number of allergens tested increased. LIMITATIONS: Data are from a single institution, and the cost per test was fixed according to Medicare Part B in 2022. CONCLUSIONS: For diagnosing ACD, we recommend considering an optimized allergen selection algorithm.

4.
Contact Dermatitis ; 90(3): 201-210, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38148670

RESUMEN

After almost three-quarters of a century during which contact dermatologists have often struggled to comprehend the relationship between metal allergy and failure of metal-alloy containing implant, it is possible to say that a relationship does exist, particularly for cobalt and chromium, but also for nickel. There is still debate as to whether allergy develops as a consequent of failure but thenceforth contributes to it, or whether sensitisation starts first and induces failure secondarily-opinion probably favours the first. Metal-on-polypropylene articulations were associated with few metal allergic problems but now are less favoured by orthopaedists due to plastic wear products causing osteolysis and pseudotumour formation through local inflammation. New metal alloys are regularly being introduced such that interested dermatologists need to stay on top of the situation. The jury is still out as to whether the recent favouring of titanium-containing alloys will confirm them to be more inert allergenically. Case reports do show some clinical reactions to titanium-containing implants and patch test series have inferred sometimes quite a high background rate of allergy, but interpretation must be tempered by the awareness that titanium salts on patch testing have a tendency to cause irritant reactions. Blood monitoring of metal ion values is now recommended in certain situations after joint replacement and increasing levels may be an indication that allergy with joint failure can develop, in which case patch testing is indicated, and suggested series are available. Predictive patch testing, whilst generally not recommended in the past, has been introduced into some protocols often by non-dermatologists, such that it is now needed for temporo-mandibular joint and Nuss bar insertion, and it can be anticipated that this may become more commonplace in the future. One of the major current deficits for patch testers is standardised guidance on which preparation or preparations to use for suspected titanium allergy. One suggestion is 0.5% titanium sulphate in petrolatum, though experience in at least one centre suggests the use of a battery of titanium salts might be desirable.


Asunto(s)
Dermatitis Alérgica por Contacto , Hipersensibilidad , Humanos , Titanio/efectos adversos , Sales (Química) , Dermatitis Alérgica por Contacto/complicaciones , Aleaciones/efectos adversos , Metales , Hipersensibilidad/etiología
5.
Contact Dermatitis ; 91(3): 186-189, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38831517

RESUMEN

BACKGROUND: Machine learning (ML) offers an opportunity in contact dermatitis (CD) research, where with full clinical picture, may support diagnosis and patch test accuracy. OBJECTIVE: This review aims to summarise the existing literature on how ML can be applied to CD in its entirety. METHODS: Embase, Medline, IEEE Xplore, and ACM Digital Library were searched from inception to February 7, 2024, for primary literature reporting on ML models in CD. RESULTS: 7834 articles were identified in the search, with 110 moving to full-text review, and six articles included. Two used ML to identify key biomarkers to help distinguish between allergic contact dermatitis (ACD) and irritant contact dermatitis (ICD), three used image data to distinguish between ACD and ICD, and one used clinical and demographical data to predict the risk of positive patch tests. All studies used supervision in their ML model training with a total of 49 704 patients across all data sets. There was sparse reporting of the accuracy of these models. CONCLUSIONS: Although the available research is still limited, there is evidence to suggest that ML has potential to support diagnostic outcomes in a clinical setting. Further research on the use of ML in clinical practice is recommended.


Asunto(s)
Dermatitis Alérgica por Contacto , Dermatitis Irritante , Aprendizaje Automático , Pruebas del Parche , Humanos , Dermatitis Alérgica por Contacto/diagnóstico , Dermatitis Alérgica por Contacto/etiología , Pruebas del Parche/métodos , Dermatitis Irritante/diagnóstico , Dermatitis Irritante/etiología , Diagnóstico Diferencial
6.
Contact Dermatitis ; 91(3): 203-211, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38778718

RESUMEN

BACKGROUND: Earlier studies suggested a potential association between tobacco smoking and nickel sensitization, but little is known about other contact allergens. OBJECTIVES: To investigate the association of smoking status and contact sensitizations as well as subtypes of dermatitis, and to analyse the sensitization profiles of tobacco smokers. PATIENTS AND METHODS: Within the Information Network of Departments of Dermatology (IVDK), we performed a cross-sectional multicentre pilot study comprising 1091 patch-tested patients from 9 departments, comparing 541 patients with a history of cigarette smoking (281 current and 260 former smokers) with 550 never-smokers. RESULTS: We could not confirm the previously reported association between nickel sensitization and tobacco smoking. Moreover, sensitizations to other allergens, including colophony, fragrance mix I, Myroxylon pereirae and formaldehyde, were not increased in cigarette smokers compared with never smokers. Hand dermatitis (50.6% vs. 33.6%) and occupational cause (36.2% vs. 22.5%) were significantly more frequent among cigarette smokers compared with never-smokers as shown by non-overlapping 95% confidence intervals. CONCLUSIONS: Although our study does not allow a firm conclusion on whether smoking status contributes to certain contact sensitizations, it confirms an association of smoking with hand dermatitis and occupational cause.


Asunto(s)
Dermatitis Alérgica por Contacto , Dermatitis Profesional , Pruebas del Parche , Humanos , Estudios Transversales , Proyectos Piloto , Dermatitis Alérgica por Contacto/etiología , Dermatitis Alérgica por Contacto/epidemiología , Dermatitis Alérgica por Contacto/diagnóstico , Masculino , Femenino , Persona de Mediana Edad , Adulto , Dermatitis Profesional/epidemiología , Dermatitis Profesional/etiología , Dermatosis de la Mano/epidemiología , Dermatosis de la Mano/etiología , Níquel/efectos adversos , Fumar Tabaco/efectos adversos , Fumar Tabaco/epidemiología , Alérgenos/efectos adversos , Anciano
7.
Contact Dermatitis ; 2024 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-39233520

RESUMEN

BACKGROUND: Existing literature has questioned the sensitivity of patch testing (PT) with cotrimoxazole (CTX) in the study of drug hypersensitivity. OBJECTIVES: Assess the sensitivity of PT with CTX in non-immediate cutaneous adverse drug reactions (CADR). PATIENTS/MATERIALS/METHODS: Retrospective analysis (2000-2022) of PT with an antibiotic series including CTX 10% pet (Chemotechnique Diagnostics©) performed according to ESCD guidelines in patients with suspected non-immediate CADR reactions to CTX. Some patients were additionally tested with in-house preparations of CTX from Bactrim DS® tablets at 10% in pet or water and trimethoprim 10% pet (Laboratórios Edol©). RESULTS: Sixty-four patients (48F/16M; mean age 47 ± 18) were included, mostly with maculopapular exanthema (51, 80%). Notably, CTX was sole suspect in 24 patients. There was no positive reaction to CTX at 10% from Chemotechnique or Bactrim DS® tablets prepared at 10% pet for patch testing. One patient reacted exclusively to trimethoprim with 1+ reaction. Two patients had a faint reaction (1+) only with the powder of Bactrim DS® tablets in water at D2, but as the reactions faded completely in 24 or 48 h, they were interpreted as irritant non-specific reactions. CONCLUSION: These findings suggest that patch testing may lack sufficient sensitivity to diagnose CTX-induced non-immediate CADR. Therefore, clinicians should be cautious interpreting CTX patch test results.

8.
Contact Dermatitis ; 90(6): 574-584, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38501375

RESUMEN

BACKGROUND: Professional ice hockey players may contract irritant and allergic contact dermatitis. AIMS: To investigate the presence of contact allergy (CA) in professional ice hockey players in Sweden. METHODS: Ten teams from the two top leagues were assessed for potential occupational exposure to sensitizers. Exactly 107 players were patch tested with an extended baseline series and a working series, in total 74 test preparations. The CA rates were compared between the ice hockey players and controls from the general population and dermatitis patients. RESULTS: One out of 4 players had at least one contact allergy. The most common sensitizers were Amerchol L 101, nickel and oxidized limonene. CA was as common in the ice hockey players as in dermatitis patients and significantly more common than in the general population. Fragrances and combined sensitizers in cosmetic products (fragrances + preservatives + emulsifier) were significantly more common in ice hockey players compared with the general population. CONCLUSION: The possible relationship between CA to fragrances and cosmetic products on the one hand and the presence of dermatitis on the other should be explored further.


Asunto(s)
Dermatitis Alérgica por Contacto , Dermatitis Profesional , Hockey , Pruebas del Parche , Humanos , Suecia/epidemiología , Dermatitis Alérgica por Contacto/etiología , Dermatitis Alérgica por Contacto/epidemiología , Dermatitis Alérgica por Contacto/diagnóstico , Adulto , Masculino , Dermatitis Profesional/etiología , Dermatitis Profesional/epidemiología , Níquel/efectos adversos , Adulto Joven , Exposición Profesional/efectos adversos , Cosméticos/efectos adversos , Perfumes/efectos adversos , Estudios de Casos y Controles , Persona de Mediana Edad , Limoneno/efectos adversos
9.
Contact Dermatitis ; 90(1): 79-83, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37840237

RESUMEN

BACKGROUND: Simultaneous overrepresentations of contact allergies and photocontact allergies are common in individuals with photocontact allergy to ketoprofen. AIMS: To investigate whether contact allergy to oxidised (ox.) geraniol, geraniol, geranial, neral and citral is overrepresented in individuals with photocontact allergy to ketoprofen. METHODS: The contact allergy rates to ox. geraniol, geraniol, geranial, neral and citral in routinely patch tested dermatitis patients were compared with the corresponding rates in individuals with photocontact allergy to ketoprofen. RESULTS: Allergic patch test reactions were noted to ox. geraniol 11% (n = 39, 5.8%), ox. geraniol 6% (n = 12, 1.8%), geraniol 6% (n = 2, 0.3%), geranial (n = 18, 2.7%), neral (n = 7, 1.0%) and citral (n = 15, 2.2%). In those four patients who were diagnosed with photocontact allergy to ketoprofen during the test period, a significant overrepresentation (p = 0.020) of simultaneous contact allergy to ox. geraniol 11% was demonstrated. Overrepresentation of simultaneous contact allergy to various combinations of ox. geraniol, ox. limonene and ox. linalool was also noted in ketoprofen-photoallergic patients. CONCLUSIONS: Contact allergy to ox. geraniol, geranial and citral is common in routinely tested dermatitis patients. There is an overrepresentation of simultaneous contact allergy to ox. geraniol, ox. limonene and ox. linalool in patients with photocontact allergy to ketoprofen.


Asunto(s)
Dermatitis Alérgica por Contacto , Dermatitis Fotoalérgica , Cetoprofeno , Humanos , Dermatitis Alérgica por Contacto/epidemiología , Dermatitis Alérgica por Contacto/etiología , Dermatitis Alérgica por Contacto/diagnóstico , Cetoprofeno/efectos adversos , Limoneno , Dermatitis Fotoalérgica/epidemiología , Dermatitis Fotoalérgica/etiología , Pruebas del Parche
10.
Contact Dermatitis ; 90(5): 470-478, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38146081

RESUMEN

BACKGROUND: EU Commission Regulation 2017/1410 prohibits using atranol and chloroatranol, the main allergens in Evernia prunastri (oakmoss), and hydroxyisohexyl 3-cyclohexene carboxaldehyde (HICC) in cosmetic products. Oakmoss absolute is contained in fragrance mix (FM) I and HICC in FM II which are patch tested as screening mixtures in the baseline series. OBJECTIVE: To describe the time trends of reaction frequencies to both FMs as well as to their components in FM-positive patients. METHODS: Retrospective analysis of data from the Information Network of Departments of Dermatology (IVDK), 2012-2021. RESULTS: Positive reactions to FM I (FM II) declined from 9.1% (4.7%) in 2012 to 4.6% (3.0%) in 2021. Full breakdown tests were performed in 24% (FM I) and 31% (FM II), respectively, of the mix-positive patients. From this data, frequencies of sensitization to the 14 single fragrances of FM I and FM II were calculated. For the majority, a decline was noted from 2012/2013 to 2020/2021, for oakmoss absolute 1.9%-0.8% and for HICC 1.8%-0.9%. CONCLUSION: EU Commission Regulation 2017/1410 was an effective measure. However, our data have some limitations, possibly causing underestimation of sensitization frequencies to fragrances.


Asunto(s)
Aldehídos , Ciclohexenos , Dermatitis Alérgica por Contacto , Perfumes , Resinas de Plantas , Terpenos , Humanos , Dermatitis Alérgica por Contacto/epidemiología , Dermatitis Alérgica por Contacto/etiología , Dermatitis Alérgica por Contacto/diagnóstico , Odorantes , Estudios Retrospectivos , Pruebas del Parche/efectos adversos , Alérgenos/efectos adversos , Perfumes/efectos adversos
11.
Contact Dermatitis ; 2024 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-39169428

RESUMEN

BACKGROUND: Photoallergic contact dermatitis (PACD) is a delayed hypersensitivity reaction to allergens only in the presence of ultraviolet radiation in sunlight. Photopatch testing (PhotoPT) is necessary to confirm the diagnosis of PACD. There are few published studies of PhotoPT in North America. OBJECTIVE: To summarise the results of patients photopatch tested by members of the North American Contact Dermatitis Group (NACDG), 2009-2020. METHODS: Retrospective analysis of patient characteristics and PhotoPT results to 32 allergens on the NACDG Photopatch Test Series. RESULTS: Most of the 454 tested patients were female (70.3%), 21-60 years old (66.7%) and White (66.7%). There were a total of 119 positive photopatch tests. Sunscreen agents comprised 88.2% of those, with benzophenones responsible for over half of them. Final diagnoses included PACD in 17.2%, allergic contact dermatitis (ACD) in 44.5%, polymorphous light eruption (PMLE) in 18.9% and chronic actinic dermatitis (CAD) in 9.0% of patients. CONCLUSIONS: In 454 patients with suspected photosensitivity referred for photopatch testing in North America, approximately one-fifth had PACD. Sunscreen agents, especially benzophenones, were the most common photoallergens. Other common diagnoses included ACD, PMLE and CAD. Photopatch testing is an important tool for differentiating these conditions.

12.
Australas J Dermatol ; 65(5): 423-427, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38706204

RESUMEN

BACKGROUND/OBJECTIVES: In the last 10 years methylisothiazolinone (MI) emerged as a global cause of preservative-related ACD. New Zealand has liberal regulations for the MI concentration limit in cosmetic products compared to Europe and Australia. The aim of this study was to evaluate the prevalence of MI sensitisation in New Zealand, explore sources of MI exposure and make recommendations on New Zealand regulations for MI use. METHODS: This retrospective study included data from patients who underwent patch testing with MI from 2008 to 2021 in a tertiary hospital dermatology clinic and a private dermatology clinic in Auckland, New Zealand. Patient baseline characteristics were recorded along with results of patch testing. Sources of MI exposure were identified from medical records. RESULTS: Over the study period, 1049 patch tests were performed in 1044 patients. MI was only tested as a stand-alone allergen from 2015; positive reactions to MI increased from 5.3% in 2015 to a peak of 11.9% in 2017 and then decreased to 6.4% in 2021. The most common source of MI exposure was shampoo or conditioner (27.7% of all relevant reactions) followed by occupational exposures to paints, biocides or glue (19.1%). CONCLUSION: Both sensitisation and ACD to MI appear to be decreasing, likely secondary to changes in product compounding due to stricter concentration limits internationally. We recommend New Zealand adopt lower MI concentration limits for cosmetics to match the limits of Australia and Europe.


Asunto(s)
Dermatitis Alérgica por Contacto , Pruebas del Parche , Tiazoles , Humanos , Nueva Zelanda , Estudios Retrospectivos , Tiazoles/efectos adversos , Dermatitis Alérgica por Contacto/etiología , Dermatitis Alérgica por Contacto/epidemiología , Femenino , Masculino , Adulto , Persona de Mediana Edad , Cosméticos/efectos adversos , Conservadores Farmacéuticos/efectos adversos , Prevalencia , Exposición Profesional/efectos adversos , Dermatitis Profesional/etiología , Dermatitis Profesional/epidemiología , Adulto Joven , Anciano
13.
Artículo en Inglés | MEDLINE | ID: mdl-38376473

RESUMEN

Summary: Background. Patch testing (PT) is used to identify substances that cause allergic contact dermatitis (ACD). However, the clinical effects of allergen restrictions following PT have not been thoroughly investigated. This study aims to assess the diagnostic accuracy of PT in patients suspected of having ACD. Methods. Prospective study. PT were performed in patients with clinical diagnosis of ACD. Patients with a positive PT (case group) had a strict restriction of the suspected substance for one month. In patients with negative patch testing (control group), allergen restriction was based in clinical history. Clinical reduction (CR) of at least 50% in disease activity (CR50%) after one month of allergen restriction was considered clinically relevant. Total control was defined as clinical reduction of at least 90% (CR90%). Results. From 400 patients, 66.2% had a positive PT. The sensitivity of PT to identify CR50% was 84%, specificity 47%, PPV 53%, and NPV 81%. Only 10.5% of patients achieved CR90%. Conclusions. The PT had moderate diagnostic accuracy. It could be useful as a screening, but a positive result should be confirmed with controlled allergen restriction. The low number of patients who achieved a 90% CR invites to reconsider the allergens included in PT and the mechanistic processes of the disease.

14.
J Am Acad Dermatol ; 89(5): 1007-1014, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37768237

RESUMEN

BACKGROUND: As both allergic contact dermatitis and atopic dermatitis (AD) have similar clinical presentations and are characterized by spongiotic dermatitis on skin biopsy, many children with AD are not referred for patch testing and allergic contact dermatitis is underdiagnosed. OBJECTIVE: To provide updated prevalence data of common contact allergens in children with and without AD. METHODS: This is a retrospective case-control study using the Pediatric Allergic Contact Dermatitis Registry from 2018 to 2022. RESULTS: A total of 912 children were included (615 with AD and 297 without AD). Children with AD were more likely to have a longer history of dermatitis (4.1 vs 1.6 years, P < .0001), have seen more providers (2.3 vs 2.1, P = .003), have greater than 1 positive patch test (PPT) result (P = .005), have a greater number of PPT results overall (2.3 vs 1.9, P = .012), and have a more generalized distribution of dermatitis (P = .001). PPT to bacitracin (P = .030), carba mix (P = .025), and cocamidopropyl betaine (P = .0007) were significantly increased in children with AD compared to those without AD. LIMITATIONS: Technical variation between providers and potential for misclassification, selection, and recall biases. CONCLUSION: Children with AD are significantly more likely to have PPT reactions and should be referred for evaluation of allergic contact dermatitis and obtain patch testing.

15.
Contact Dermatitis ; 89(6): 434-441, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37820718

RESUMEN

The sesquiterpene lactones (SLs) are secondary plant metabolites, which are widespread in the Compositae/Asteraceae plant family. The first SLs were detected more than 100 years ago, and allergic contact dermatitis from Compositae has been reported since the beginning of the 1900s, but it was not until the late 1960s and early 1970s that a collaboration between dermatologists, chemists and botanists led to the detection of SLs as the main allergens of Compositae plants. In the 1980s, the SL mix, consisting of equimolar amounts of alantolactone, costunolide and dehydrocostus lactone, was developed as a screening agent for Compositae sensitisation. Today, after inclusion of SL mix in the baseline series, the mean prevalence of reactions in Europe is around 1%, and in North America 0.8%. In countries outside Europe and North America, the prevalence ranges between 0% and 10.7%. The detection rate of SL mix is lower than that of some plant extracts, and ideally, SL mix should be supplemented with a mix of SLs from locally prevalent allergenic plants. The prevalence of positive reactions to SL mix suggests continued baseline testing in most European countries, North America, New Zealand, Australia and probably some Chinese centres.


Asunto(s)
Asteraceae , Dermatitis Alérgica por Contacto , Sesquiterpenos , Humanos , Dermatitis Alérgica por Contacto/diagnóstico , Pruebas del Parche , Alérgenos , Lactonas , Plantas
16.
Contact Dermatitis ; 88(1): 54-59, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36112512

RESUMEN

BACKGROUND: The textile dye mix (TDM) 6.6% in petrolatum contains Disperse Blue (DB) 35, Disperse Yellow 3, Disperse Orange (DO) 1 and 3, Disperse Red 1 and 17, and DB 106 and 124. The most frequent allergen in TDM-positive patients is DO 3. Around 85% of para-phenylenediamine (PPD)-allergic dermatitis patients have been positive to DO 3. There has been a discussion to exclude DO 3 from TDM 6.6% because of strong simultaneous reactions to TDM and PPD. OBJECTIVES: To study if DO 3 can be excluded from TDM 6.6%. METHODS: Patch tests were performed on 1481 dermatitis patients with TDM 6.6%, TDM 7.0% (without DO 3 but the other disperse dyes at 1.0% each), DO 3 1.0%, and PPD 1.0% pet. RESULTS: Contact allergy to TDM 6.6% was 3.6% and to TDM 7.0% was 3.0%. All 26 DO 3-positive patients were positive to PPD. The 44 patients positive to TDM 7.0% plus the 13 positive to PPD and TDM 6.6% but negative to TDM 7.0% were 57, outnumbering the 53 positive to TDM 6.6%. CONCLUSION: TDM 7.0% can replace TDM 6.6% in the Swedish baseline series, since TDM 7.0% together with PPD 1.0% will detect patients with textile dye allergy.


Asunto(s)
Dermatitis Alérgica por Contacto , Humanos , Pruebas del Parche/efectos adversos , Dermatitis Alérgica por Contacto/diagnóstico , Dermatitis Alérgica por Contacto/etiología , Suecia , Textiles/efectos adversos , Colorantes/efectos adversos
17.
Contact Dermatitis ; 88(4): 249-262, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36458568

RESUMEN

Vulvar allergic contact dermatitis (vACD) and irritant contact dermatitis (vICD) are common and accompanied by a great burden on the patient's life. We aimed to review the existing literature on vACD and vICD in order to provide a comprehensive reference list of potential vulvar allergens and irritants, as well as to establish the role of patch testing therein. A systematic search was performed in Medline, Embase and Web of Science using a search string based on the PICO-format. The study protocol was registered at PROSPERO (CRD42021239527). Multiple allergens were identified and included metals, topical drugs, fragrances, preservatives, cosmetic constituents and rubber components. Not all positive reactions were, however, considered to be relevant. Patch testing is the primary tool for the identification of the causal allergens. Testing with standard series alone was proven to be insufficient. Little information about irritants was found. In the future, additional series and late readings should be considered in standard practice. Studies on vICD are scarce and further research is necessary. More population-based research should be performed.


Asunto(s)
Dermatitis Alérgica por Contacto , Dermatitis Irritante , Femenino , Humanos , Alérgenos , Irritantes , Dermatitis Alérgica por Contacto/etiología , Pruebas del Parche/métodos , Dermatitis Irritante/etiología , Vulva
18.
Contact Dermatitis ; 88(3): 220-229, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36461774

RESUMEN

BACKGROUND: Textile dye mix (TDM) is included in the European baseline series (EBS), but it is unknown if TDM identifies all patients with a textile dye allergy. OBJECTIVES: To assess the added value of performing patch testing with individual textile dyes in addition to TDM. METHODS: Two hundred and nine patients suspected to have a contact allergy to textile dyes were patch tested between January 2015 and December 2021 with the EBS, as well as an individual textile dye test series containing textile dyes part of TDM (TDM-dyes) and outside the scope of TDM (non-TDM dyes). RESULTS: Fifty-four patients (25.8%) tested positive for TDM or an individual textile dye. Disperse Orange 3 (9.6%) followed by Disperse Blue 106 (4.8%) were the most common individual textile dyes causing a positive patch test reaction. Of the 54 dye positive patients, 28 (51.9%) had a clinically relevant reaction. No clinically relevant reactions were seen in patients that solely tested positive for non-TDM dyes. CONCLUSIONS: It is beneficial to test individual textile dyes in addition to TDM in patients suspected of having a textile dye allergy. Otherwise, 46.3% of the dye positive patients and 35.7% of the patients with a clinically relevant reaction would have been missed.


Asunto(s)
Dermatitis Alérgica por Contacto , Humanos , Dermatitis Alérgica por Contacto/diagnóstico , Dermatitis Alérgica por Contacto/epidemiología , Dermatitis Alérgica por Contacto/etiología , Pruebas del Parche/efectos adversos , Prevalencia , Textiles/efectos adversos , Colorantes/efectos adversos , Alérgenos/efectos adversos
19.
Contact Dermatitis ; 88(4): 263-274, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36694979

RESUMEN

BACKGROUND: Occupational skin diseases have led the occupational disease statistics in Europe for many years. Especially occupational allergic contact dermatitis is associated with a poor prognosis and low healing rates leading to an enormous burden for the affected individual and for society. OBJECTIVES: To present the sensitization frequencies to the most relevant allergens of the European baseline series in patients with occupational contact dermatitis (OCD) and to compare sensitization profiles of different occupations. METHODS: The data of 16 022 patients considered having OCD after patch testing within the European Surveillance System on Contact Allergies (ESSCA) network between January 2011 and December 2020 were evaluated. Patients (n = 46 652) in whom an occupational causation was refuted served as comparison group. RESULTS: The highest percentages of OCD were found among patients working in agriculture, fishery and related workers, metal industry, chemical industry, followed by building and construction industry, health care, food and service industry. Sensitizations to rubber chemicals (thiurams, carbamates, benzothiazoles) and epoxy resins were associated with at least a doubled risk of OCD. After a decline from 2014 onwards, the risks to acquire an occupation-related sensitization to methyl(chloro)isothiazolinone (MCI/MI) and especially to methylisothiazolinone (MI) seem to increase again. Sensitization rates to formaldehyde were stable, and to methyldibromo glutaronitrile (MDBGN) slightly decreasing over time. CONCLUSIONS: Among allergens in the European Baseline Series, occupational relevance is most frequently attributed to rubber accelerators, epoxy resins and preservatives.


Asunto(s)
Dermatitis Alérgica por Contacto , Dermatitis Profesional , Humanos , Dermatitis Alérgica por Contacto/etiología , Pruebas del Parche/efectos adversos , Goma , Resinas Epoxi , Dermatitis Profesional/etiología , Alérgenos , Benzotiazoles
20.
Contact Dermatitis ; 89(2): 79-84, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37100088

RESUMEN

BACKGROUND: Propylene glycol (PG) is used in a variety of cosmetics, food and pharmaceuticals. PG is a known sensitizer but also irritating when patch tested (PT). OBJECTIVES: The aims were to investigate the frequency of contact sensitization to PG and to identify cases of allergic contact dermatitis (ACD). METHODS: A retrospective study was performed on patients PT at the Skin Health Institute (SHI), Victoria, Australia to PG 5% pet. and PG 10% aq. between 1 January 2005 and 31 December 2020. RESULTS: In all, 6761 patients were PT to PG and 21 (0.31%) reacted. Of those 21 individuals, 9 (42.9%) had a relevant reaction. 75% of relevant positive reactions were in patients PT to PG 10% aq. The most common source of PG exposure was topical medicaments (77.8% of relevant reactions) and moisturizers, with the largest group being topical corticosteroids. CONCLUSION: Contact sensitization to PG in the patch test population remains uncommon, although it is possible that testing with concentrations of 5%-10% PG did not identify all reactions. Topical corticosteroids were the most important cause. Patients with suspected contact dermatitis to topical corticosteroids should be PT to PG.


Asunto(s)
Dermatitis Alérgica por Contacto , Fármacos Dermatológicos , Humanos , Dermatitis Alérgica por Contacto/diagnóstico , Dermatitis Alérgica por Contacto/epidemiología , Dermatitis Alérgica por Contacto/etiología , Estudios Retrospectivos , Propilenglicol/efectos adversos , Alérgenos/efectos adversos , Pruebas del Parche/efectos adversos , Victoria/epidemiología , Glucocorticoides/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA