NMR Biomed ; : e5180, 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38775032

RESUMEN

Ultrahigh field magnetic resonance imaging (MRI) (≥ 7 T) has the potential to provide superior spatial resolution and unique image contrast. Apart from radiofrequency transmit inhomogeneities in the body at this field strength, imaging of the upper abdomen faces additional challenges associated with motion-induced ghosting artifacts. To address these challenges, the goal of this work was to develop a technique for high-resolution free-breathing upper abdominal MRI at 7 T with a large field of view. Free-breathing 3D gradient-recalled echo (GRE) water-excited radial stack-of-stars data were acquired in seven healthy volunteers (five males/two females, body mass index: 19.6-24.8 kg/m2) at 7 T using an eight-channel transceive array coil. Two volunteers were also examined at 3 T. In each volunteer, the liver and kidney regions were scanned in two separate acquisitions. To homogenize signal excitation, the time-interleaved acquisition of modes (TIAMO) method was used with personalized pairs of B1 shims, based on a 23-s Cartesian fast low angle shot (FLASH) acquisition. Utilizing free-induction decay navigator signals, respiratory-gated images were reconstructed at a spatial resolution of 0.8 × 0.8 × 1.0 mm3. Two experienced radiologists rated the image quality and the impact of B1 inhomogeneity and motion-related artifacts on multipoint scales. The images of all volunteers showcased effective water excitation and were accurately corrected for respiratory motion. The impact of B1 inhomogeneity on image quality was minimal, underscoring the efficacy of the multitransmit TIAMO shim. The high spatial resolution allowed excellent depiction of small structures such as the adrenal glands, the proximal ureter, the diaphragm, and small blood vessels, although some streaking artifacts persisted in liver image data. In direct comparisons with 3 T performed for two volunteers, 7-T acquisitions demonstrated increases in signal-to-noise ratio of 77% and 58%. Overall, this work demonstrates the feasibility of free-breathing MRI in the upper abdomen at submillimeter spatial resolution at a magnetic field strength of 7 T.

2.
NMR Biomed ; 37(8): e5134, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38459747

RESUMEN

Free-breathing abdominal chemical exchange saturation transfer (CEST) has great potential for clinical application, but its technical implementation remains challenging. This study aimed to propose and evaluate a free-breathing abdominal CEST sequence. The proposed sequence employed respiratory gating (ResGat) to synchronize the data acquisition with respiratory motion and performed a water presaturation module before the CEST saturation to abolish the influence of respiration-induced repetition time variation. In vivo experiments were performed to compare different respiratory motion-control strategies and B0 offset correction methods, and to evaluate the effectiveness and necessity of the quasi-steady-state (QUASS) approach for correcting the influence of the water presaturation module on CEST signal. ResGat with a target expiratory phase of 0.5 resulted in a higher structural similarity index and a lower coefficient of variation on consecutively acquired CEST S0 images than breath-holding (BH) and respiratory triggering (all p < 0.05). B0 maps derived from the abdominal CEST dataset itself were more stable for B0 correction, compared with the separately acquired B0 maps by a dual-echo time scan and B0 maps derived from the water saturation shift referencing approach. Compared with BH, ResGat yielded more homogeneous magnetization transfer ratio asymmetry maps at 3.5 ppm (standard deviation: 3.96% vs. 3.19%, p = 0.036) and a lower mean squared difference between scan and rescan (27.52‱ vs. 16.82‱, p = 0.004). The QUASS approach could correct the water presaturation-induced CEST signal change, but its necessity for in vivo scanning needs further verification. The proposed free-breathing abdominal CEST sequence using ResGat had an acquisition efficiency of approximately four times that using BH. In conclusion, the proposed free-breathing abdominal CEST sequence using ResGat and water presaturation has a higher acquisition efficiency and image quality than abdominal CEST using BH.


Asunto(s)
Abdomen , Imagen por Resonancia Magnética , Respiración , Técnicas de Imagen Sincronizada Respiratorias , Agua , Abdomen/diagnóstico por imagen , Humanos , Agua/química , Técnicas de Imagen Sincronizada Respiratorias/métodos , Masculino , Imagen por Resonancia Magnética/métodos , Adulto , Femenino
3.
J Appl Clin Med Phys ; 25(8): e14376, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38695849

RESUMEN

PURPOSE: To propose a straightforward and time-efficient quality assurance (QA) approach of beam time delay for respiratory-gated radiotherapy and validate the proposed method on typical respiratory gating systems, Catalyst™ and AlignRT™. METHODS: The QA apparatus was composed of a motion platform and a Winston-Lutz cube phantom (WL3) embedded with metal balls. The apparatus was first scanned in CT-Sim and two types of QA plans specific for beam on and beam off time delay, respectively, were designed. Static reference images and motion testing images of the WL3 cube were acquired with EPID. By comparing the position differences of the embedded metal balls in the motion and reference images, beam time delays were determined. The proposed approach was validated on three linacs with either Catalyst™ or AlignRT™ respiratory gating systems. To investigate the impact of energy and dose rate on beam time delay, a range of QA plans with Eclipse (V15.7) were devised with varying energy and dose rates. RESULTS: For all energies, the beam on time delays in AlignRT™ V6.3.226, AlignRT™ V7.1.1, and Catalyst™ were 92.13 ± $ \pm $ 5.79 ms, 123.11 ± $ \pm $ 6.44 ms, and 303.44 ± $ \pm $ 4.28 ms, respectively. The beam off time delays in AlignRT™ V6.3.226, AlignRT™ V7.1.1, and Catalyst™ were 121.87 ± $ \pm $ 1.34 ms, 119.33 ± $ \pm $ 0.75 ms, and 97.69 ± $ \pm $ 2.02 ms, respectively. Furthermore, the beam on delays decreased slightly as dose rates increased for all gating systems, whereas the beam off delays remained unaffected. CONCLUSIONS: The validation results demonstrate the proposed QA approach of beam time delay for respiratory-gated radiotherapy was both reproducible and time-efficient to practice for institutions to customize accordingly.


Asunto(s)
Fantasmas de Imagen , Garantía de la Calidad de Atención de Salud , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Garantía de la Calidad de Atención de Salud/normas , Aceleradores de Partículas/instrumentación , Respiración , Técnicas de Imagen Sincronizada Respiratorias/métodos , Neoplasias/radioterapia , Factores de Tiempo
4.
Magn Reson Med ; 89(5): 1931-1944, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36594436

RESUMEN

PURPOSE: To increase the effectiveness of respiratory gating in radial stack-of-stars MRI, particularly when imaging at high spatial resolutions or with multiple echoes. METHODS: Free induction decay (FID) navigators were integrated into a three-dimensional gradient echo radial stack-of-stars pulse sequence. These navigators provided a motion signal with a high temporal resolution, which allowed single-spoke binning (SSB): each spoke at each phase encode step was sorted individually to the corresponding motion state of the respiratory signal. SSB was compared with spoke-angle binning (SAB), in which all phase encode steps of one projection angle were sorted without the use of additional navigator data. To illustrate the benefit of SSB over SAB, images of a motion phantom and of six free-breathing volunteers were reconstructed after motion-gating using either method. Image sharpness was quantitatively compared using image gradient entropies. RESULTS: The proposed method resulted in sharper images of the motion phantom and free-breathing volunteers. Differences in gradient entropy were statistically significant (p = 0.03) in favor of SSB. The increased accuracy of motion-gating led to a decrease of streaking artifacts in motion-gated four-dimensional reconstructions. To consistently estimate respiratory signals from the FID-navigator data, specific types of gradient spoiler waveforms were required. CONCLUSION: SSB allowed high-resolution motion-corrected MR imaging, even when acquiring multiple gradient echo signals or large acquisition matrices, without sacrificing accuracy of motion-gating. SSB thus relieves restrictions on the choice of pulse sequence parameters, enabling the use of motion-gated radial stack-of-stars MRI in a broader domain of clinical applications.


Asunto(s)
Artefactos , Interpretación de Imagen Asistida por Computador , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Abdomen/diagnóstico por imagen , Movimiento (Física) , Respiración , Imagenología Tridimensional/métodos
5.
Strahlenther Onkol ; 199(11): 1000-1010, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37728734

RESUMEN

PURPOSE: Stereotactic body radiotherapy (SBRT) has been firmly established as a treatment choice for patients with oligometastases, as it has demonstrated both safety and efficacy by consistently achieving high rates of local control. Moreover, it offers potential survival benefits for carefully selected patients in real-world clinical settings. METHODS: Between January 2008 and May 2020, a total of 149 patients (with 414 liver metastases) received treatment. The Active Breathing Coordinator device was used for 68 patients, while respiratory gating was used for 65 and abdominal compression was used for 16 patients. The most common histological finding was colorectal adenocarcinoma, with 37.6% of patients having three or more metastases, and 18% having two metastases. The prescribed dose ranged from 36 to 60 Gy, delivered in 3-5 fractions. RESULTS: Local control rates at 2 and 3 years were 76.1% and 61.2%, respectively, with no instances of local recurrence after 3 years. Factors negatively impacting local control included colorectal histology, lower prescribed dose, and the occurrence of new liver metastases. The median overall survival from SBRT was 32 months, with the presence of metastases outside the liver and the development of new liver metastases after SBRT affecting survival. The median disease-free survival was 10 months. No substantial differences in both local control and survival were observed between the respiratory motion control techniques employed. Treatment tolerance was excellent, with only one patient experiencing acute grade IV thrombocytopenia and two patients suffering from ≥ grade II chronic toxicity. CONCLUSION: For radical management of single or multiple liver metastases, SBRT is an effective and well-tolerated treatment option. Regardless of the technology employed, experienced physicians can achieve similarly positive outcomes. However, additional studies are required to elucidate prognostic factors that can facilitate improved patient selection.


Asunto(s)
Neoplasias Colorrectales , Neoplasias Hepáticas , Radiocirugia , Humanos , Radiocirugia/efectos adversos , Pronóstico , Fraccionamiento de la Dosis de Radiación , Estudios Retrospectivos , Tasa de Supervivencia , Neoplasias Hepáticas/secundario , Neoplasias Colorrectales/radioterapia
6.
Eur Radiol ; 33(5): 3366-3376, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36565352

RESUMEN

OBJECTIVES: This study aimed to investigate the performance of respiratory-gating imaging with reduced acquisition time using the total-body positron emission tomography/computed tomography (PET/CT) scanner. METHODS: Imaging data of 71 patients with suspect malignancies who underwent total-body 2-[18F]-fluoro-2-deoxy-D-glucose PET/CT for 15 min with respiration recorded were analyzed. For each examination, four reconstructions were performed: Ungated-15, using all coincidences; Ungated-5, using data of the first 5 min; Gated-15 using all coincidences but with respiratory gating; and Gated-6 using data of the first 6 min with respiratory gating. Lesions were quantified and image quality was evaluated; both were compared between the four image sets. RESULTS: A total of 390 lesions were found in the thorax and upper abdomen. Lesion detectability was significantly higher in gated-15 (97.2%) than in ungated-15 (93.6%, p = 0.001) and ungated-5 (92.3%, p = 0.001), but comparable to Gated-6 (95.9%, p = 0.993). A total of 131 lesions were selected for quantitative analyses. Lesions in Gated-15 presented significantly larger standardized uptake values, tumor-to-liver ratio, and tumor-to-blood ratio, but smaller metabolic tumor volume, compared to those in Ungated-15 and Ungated-5 (all p < 0.001). These differences were more obvious in small lesions and in lesions from sites other than mediastinum/retroperitoneum. However, these indices were not significantly different between Gated-15 and Gated-6. Higher, but acceptable, image noise was identified in gated images than in ungated images. CONCLUSIONS: Respiratory-gating imaging with reduced scanning time using the total-body PET/CT scanner is superior to ungated imaging and can be used in the clinic. KEY POINTS: • In PET imaging, respiratory gating can improve lesion presentation and detectability but requires longer imaging time. • This single-center study showed that the total-body PET scanner allows respiratory-gated imaging with reduced and clinically acceptable scanning time.


Asunto(s)
Neoplasias Hepáticas , Técnicas de Imagen Sincronizada Respiratorias , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía Computarizada por Rayos X/métodos , Tomografía de Emisión de Positrones/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Desoxiglucosa , Fluorodesoxiglucosa F18
7.
J Appl Clin Med Phys ; 24(5): e13967, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36943700

RESUMEN

OBJECTIVE: Texture analysis is one of the lung cancer countermeasures in the field of radiomics. Even though image quality affects texture features, the reproducibility of principal component analysis (PCA)-based data-driven respiratory gating (DDG) on texture features remains poorly understood. Hence, this study aimed to clarify the reproducibility of PCA-based DDG on texture features in non-small cell lung cancer (NSCLC) patients with 18 F-Fluorodeoxyglucose (18 F-FDG) Positron emission tomography/computed tomography (PET/CT). METHODS: Twenty patients with NSCLC who underwent 18 F-FDG PET/CT in routine clinical practice were retrospectively analyzed. Each patient's PET data were reconstructed in two PET groups of no gating (NG-PET) and PCA-based DDG gating (DDG-PET). Forty-six image features were analyzed using LIFEx software. Reproducibility was evaluated using Lin's concordance correlation coefficient ( ρ c ${\rho _c}$ ) and percentage difference (%Diff). Non-reproducibility was defined as having unacceptable strength ( ρ c $({\rho _c}$  < 0.8) and a %Diff of >10%. NG-PET and DDG-PET were compared using the Wilcoxon signed-rank test. RESULTS: A total of 3/46 (6.5%) image features had unacceptable strength, and 9/46 (19.6%) image features had a %Diff of >10%. Significant differences between the NG-PET and DDG-PET groups were confirmed in only 4/46 (8.7%) of the high %Diff image features. CONCLUSION: Although the DDG application affected several texture features, most image features had adequate reproducibility. PCA-based DDG-PET can be routinely used as interchangeable images for texture feature extraction from NSCLC patients.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Fluorodesoxiglucosa F18 , Neoplasias Pulmonares/diagnóstico por imagen , Análisis de Componente Principal , Estudios Retrospectivos
8.
J Appl Clin Med Phys ; 23(8): e13705, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35737295

RESUMEN

PURPOSE: Motion management of tumors within the lung and abdomen is challenging because it requires balancing tissue sparing with accuracy of hitting the target, while considering treatment delivery efficiency. Physicists can play an important role in analyzing four-dimensional computed tomography (4DCT) data to recommend the optimal respiratory gating parameters for a patient. The goal of this work was to develop a standardized procedure for making recommendations regarding gating parameters and planning margins for lung and gastrointestinal stereotactic body radiotherapy (SBRT) treatments. In doing so, we hoped to simplify decision-making and analysis, and provide a tool for troubleshooting complex cases. METHODS: Factors that impact gating decisions and planning target volume (PTV) margins were identified. The gating options included gating on exhale with approximately a 50% duty cycle (Gate3070), exhale gating with a reduced duty cycle (Gate4060), and treating for most of respiration, excluding only extreme inhales and exhales (Gate100). A standard operating procedure was developed, as well as a physics consult document to communicate motion management recommendations to other members of the treatment team. This procedure was implemented clinically for 1 year and results are reported below. RESULTS: Identified factors that impact motion management included the magnitude of motion observed on 4DCT, the regularity of breathing and quality of 4DCT data, and ability to observe the target on fluoroscopy. These were collated into two decision tables-one specific to lung tumors and another for gastrointestinal tumors-such that a physicist could answer a series of questions to determine the optimal gating and PTV margin. The procedure was used clinically for 252 sites from 213 patients treated with respiratory-gated SBRT and standardized practice across our 12-member physics team. CONCLUSION: Implementation of a standardized procedure for respiratory gating had a positive impact in our clinic, improving efficiency and ease of 4DCT analysis and standardizing gating decision-making amongst physicists.


Asunto(s)
Neoplasias Pulmonares , Radiocirugia , Tomografía Computarizada Cuatridimensional/métodos , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirugía , Movimiento (Física) , Movimiento , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Respiración , Flujo de Trabajo
9.
J Appl Clin Med Phys ; 23(9): e13666, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35950272

RESUMEN

PURPOSE: The commercial 0.35-T magnetic resonance imaging (MRI)-guided radiotherapy vendor ViewRay recently introduced upgraded real-time imaging frame rates based on compressed sensing techniques. Furthermore, additional motion tracking algorithms were made available. Compressed sensing allows for increased image frame rates but may compromise image quality. To assess the impact of this upgrade on respiratory gating accuracy, we evaluated gated dose distributions pre- and post-upgrade using a motion phantom and radiochromic film. METHODS: Seven motion waveforms (four artificial, two patient-derived free-breathing, and one breath-holding) were used to drive an MRI-compatible motion phantom. A treatment plan was developed to deliver a 3-cm diameter spherical dose distribution typical of a stereotactic body radiotherapy plan. Gating was performed using 4-frames per second (fps) imaging pre-upgrade on the "default" tracking algorithm and 8-fps post-upgrade using the "small mobile targets" (SMT) and "large deforming targets" (LDT) tracking algorithms. Radiochromic film was placed in a moving insert within the phantom to measure dose. The planned and delivered dose distributions were compared using the gamma index with 3%/3-mm criteria. Dose-area histograms were produced to calculate the dose to 95% (D95) of the sphere planning target volume (PTV) and two simulated gross tumor volumes formed by contracting the PTV by 3 and 5 mm, respectively. RESULTS: Gamma pass rates ranged from 18% to 93% over the 21 combinations of breathing trace and gating conditions examined. D95 ranged from 206 to 514 cGy. On average, the LDT algorithm yielded lower gamma and D95 values than the default and SMT algorithms. CONCLUSION: Respiratory gating at 8 fps with the new tracking algorithms provides similar gating performance to the original algorithm with 4 fps, although the LDT algorithm had lower accuracy for our non-deformable target. This indicates that the choice of deformable image registration algorithm should be chosen deliberately based on whether the target is rigid or deforming.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Espectroscopía de Resonancia Magnética , Movimiento , Aceleradores de Partículas , Fantasmas de Imagen , Radiometría/métodos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos
10.
J Magn Reson Imaging ; 54(2): 440-451, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33694310

RESUMEN

BACKGROUND: Respiratory gating is generally recommended in 4D flow MRI of the heart to avoid blurring and motion artifacts. Recently, a novel automated contact-less camera-based respiratory motion sensor has been introduced. PURPOSE: To compare camera-based respiratory gating (CAM) with liver-lung-navigator-based gating (NAV) and no gating (NO) for whole-heart 4D flow MRI. STUDY TYPE: Retrospective. SUBJECTS: Thirty two patients with a spectrum of cardiovascular diseases. FIELD STRENGTH/SEQUENCE: A 3T, 3D-cine spoiled-gradient-echo-T1-weighted-sequence with flow-encoding in three spatial directions. ASSESSMENT: Respiratory phases were derived and compared against each other by cross-correlation. Three radiologists/cardiologist scored images reconstructed with camera-based, navigator-based, and no respiratory gating with a 4-point Likert scale (qualitative analysis). Quantitative image quality analysis, in form of signal-to-noise ratio (SNR) and liver-lung-edge (LLE) for sharpness and quantitative flow analysis of the valves were performed semi-automatically. STATISTICAL TESTS: One-way repeated measured analysis of variance (ANOVA) with Wilks's lambda testing and follow-up pairwise comparisons. Significance level of P ≤ 0.05. Krippendorff's-alpha-test for inter-rater reliability. RESULTS: The respiratory signal analysis revealed that CAM and NAV phases were highly correlated (C = 0.93 ± 0.09, P < 0.01). Image scoring showed poor inter-rater reliability and no significant differences were observed (P ≥ 0.16). The image quality comparison showed that NAV and CAM were superior to NO with higher SNR (P = 0.02) and smaller LLE (P < 0.01). The quantitative flow analysis showed significant differences between the three respiratory-gated reconstructions in the tricuspid and pulmonary valves (P ≤ 0.05), but not in the mitral and aortic valves (P > 0.05). Pairwise comparisons showed that reconstructions without respiratory gating were different in flow measurements to either CAM or NAV or both, but no differences were found between CAM and NAV reconstructions. DATA CONCLUSION: Camera-based respiratory gating performed as well as conventional liver-lung-navigator-based respiratory gating. Quantitative image quality analysis showed that both techniques were equivalent and superior to no-gating-reconstructions. Quantitative flow analysis revealed local flow differences (tricuspid/pulmonary valves) in images of no-gating-reconstructions, but no differences were found between images reconstructed with camera-based and navigator-based respiratory gating. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Imagen por Resonancia Magnética , Técnicas de Imagen Sincronizada Respiratorias , Artefactos , Humanos , Imagenología Tridimensional , Reproducibilidad de los Resultados , Estudios Retrospectivos , Relación Señal-Ruido
11.
J Appl Clin Med Phys ; 22(1): 218-225, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33378792

RESUMEN

PURPOSE: Deep inspiration breath hold (DIBH) and respiratory gating (RG) are widely used to reduce movement of target and healthy organs caused by breathing during irradiation. We hypothesized that accuracy and efficiency comparable to DIBH can be achieved with RG for pancreas treatment. METHODS AND MATERIALS: Twenty consecutive patients with pancreatic cancer treated with DIBH (eight) or RG (twelve) volumetric modulated arc therapy during 2017-2019 were included in this study, with radiopaque markers implanted near or in the targets. Seventeen patients received 25 fractions, while the other three received 15 fractions. Only patients who could not tolerate DIBH received RG treatment. While both techniques relied on respiratory signals from external markers, internal target motions were monitored with kV X-ray imaging during treatment. A 3-mm external gating window was used for DIBH treatment; RG treatment was centered on end-expiration with a duty cycle of 40%, corresponding to an external gating window of 2-3 mm. During dose delivery, kV images were automatically taken every 20◦ or 40◦ gantry rotation, from which internal markers were identified. The marker displacement from their initial positions and the residual motion amplitudes were calculated. For the analysis of treatment efficiency, the treatment time of every session was calculated from the motion management waveform files recorded at the treatment console. RESULTS: Within one fraction, the displacement was 0-5 mm for DIBH and 0-6 mm for RG. The average magnitude of displacement for each patient during the entire course of treatment ranged 0-3 mm for both techniques. No statistically significant difference in displacement or residual motion was observed between the two techniques. The average treatment time was 15 min for DIBH and 17 min for RG, with no statistical significance. CONCLUSIONS: The accuracy and efficiency were comparable between RG and DIBH treatment for pancreas irradiation. RG is a feasible alternative strategy to DIBH.


Asunto(s)
Neoplasias Pancreáticas , Radioterapia de Intensidad Modulada , Contencion de la Respiración , Humanos , Páncreas , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/radioterapia , Planificación de la Radioterapia Asistida por Computador , Tomografía Computarizada por Rayos X
12.
J Nucl Cardiol ; 27(2): 634-647, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-30088195

RESUMEN

BACKGROUND: Respiratory gating reduces motion blurring in cardiac SPECT. Here we aim to evaluate the performance of three respiratory gating strategies using a population of digital phantoms with known truth and clinical data. METHODS: We analytically simulated 60 projections for 10 XCAT phantoms with 99mTc-sestamibi distributions using three gating schemes: equal amplitude gating (AG), equal count gating (CG), and equal time gating (TG). Clinical list-mode data for 10 patients who underwent 99mTc-sestamibi scans were also processed using the 3 gating schemes. Reconstructed images in each gate were registered to a reference gate, averaged and reoriented to generate the polar plots. For simulations, image noise, relative difference (RD) of averaged count for each of the 17 segment, and relative defect size difference (RSD) were analyzed. For clinical data, image intensity profile and FWHM were measured across the left ventricle wall. RESULTS: For simulations, AG and CG methods showed significantly lower RD and RSD compared to TG, while noise variation was more non-uniform through different gates for AG. In the clinical study, AG and CG had smaller FWHM than TG. CONCLUSIONS: AG and CG methods show better performance for motion reduction and are recommended for clinical respiratory gating SPECT implementation.


Asunto(s)
Corazón/diagnóstico por imagen , Respiración , Tomografía Computarizada de Emisión de Fotón Único/métodos , Adulto , Anciano , Anciano de 80 o más Años , Artefactos , Simulación por Computador , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Movimiento (Física) , Fantasmas de Imagen , Reproducibilidad de los Resultados , Técnicas de Imagen Sincronizada Respiratorias/métodos , Tecnecio Tc 99m Sestamibi
13.
J Nucl Cardiol ; 27(6): 2216-2230, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-30761482

RESUMEN

BACKGROUND: Respiratory patient motion causes blurring of the PET images that may impact accurate quantification of perfusion and infarction extents in PET myocardial viability studies. In this study, we investigate the feasibility of correcting for respiratory motion directly in the PET-listmode data prior to image reconstruction using a data-driven, projection-based, respiratory motion compensation (DPR-MoCo) technique. METHODS: The DPR-MoCo method was validated using simulations of a XCAT phantom (Biograph mMR PET/MR) as well as experimental phantom acquisitions (Biograph mCT PET/CT). Seven patient studies following a dual-tracer (18F-FDG/13N-NH3) imaging-protocol using a PET/MR-system were also evaluated. The performance of the DPR-MoCo method was compared against reconstructions of the acquired data (No-MoCo), a reference gate method (gated) and an image-based MoCo method using the standard reconstruction-transform-average (RTA-MoCo) approach. The target-to-background ratio (TBRLV) in the myocardium and the noise in the liver (CoVliver) were evaluated for all acquisitions. For all patients, the clinical effect of the DPR-MoCo was assessed based on the end-systolic (ESV), the end-diastolic volumes (EDV) and the left ventricular ejection fraction (EF) which were compared to functional values obtained from the cardiac MR. RESULTS: The DPR-MoCo and the No-MoCo images presented with similar noise-properties (CoV) (P = .12), while the RTA-MoCo and reference-gate images showed increased noise levels (P = .05). TBRLV values increased for the motion limited reconstructions when compared to the No-MoCo reconstructions (P > .05). DPR-MoCo results showed higher correlation with the functional values obtained from the cardiac MR than the No-MoCo results, though non-significant (P > .05). CONCLUSION: The projection-based DPR-MoCo method helps to improve PET image quality of the myocardium without the need for external devices for motion tracking.


Asunto(s)
Corazón/diagnóstico por imagen , Imagen por Resonancia Magnética , Tomografía Computarizada por Tomografía de Emisión de Positrones , Anciano , Anciano de 80 o más Años , Simulación por Computador , Diástole , Electrocardiografía , Femenino , Fluorodesoxiglucosa F18 , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Movimiento , Miocardio/patología , Fantasmas de Imagen , Reproducibilidad de los Resultados , Respiración , Volumen Sistólico , Sístole , Función Ventricular Izquierda
14.
Artículo en Japonés | MEDLINE | ID: mdl-32814734

RESUMEN

PURPOSE: This phantom study aimed to determine the optimal acquisition window size for phase-based respiratory gating in silicon photomultiplier (SiPM)-based fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) and its acquisition time in respiratory-gated imaging with the optimal window size. METHODS: Images of a moving NEMA IEC Body Phantom SetTM with hot spheres were acquired. First, the tumor volume and the maximum standardized uptake value (SUVmax) of images reconstructed using a different window size were evaluated to define the optimal window size. Second, the quality of the images reconstructed using the optimal window size and different acquisition times was evaluated using the detectability score of the 10-mm hot sphere and physical indices. RESULTS: The volume and the SUVmax of the 10-mm hot sphere were improved when the window size was narrow, and there were no significant differences among images reconstructed using a window size narrower than 20%. To reconstruct an image using the 20% window size, an acquisition time of 5 min was required to visualize the 10-mm hot sphere. CONCLUSIONS: The optimal window size for phase-based respiratory gating is 20%. Further, an acquisition time of 5 min should be taken for respiratory-gated imaging with the 20% window size on SiPM-based FDG-PET/CT.


Asunto(s)
Fluorodesoxiglucosa F18 , Tomografía Computarizada por Tomografía de Emisión de Positrones , Fantasmas de Imagen , Tomografía de Emisión de Positrones , Tomógrafos Computarizados por Rayos X
15.
Magn Reson Med ; 82(1): 159-173, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30859615

RESUMEN

PURPOSE: To quantify the tissue sodium concentration (TSC) in cardiac 23 Na MRI. To evaluate the influence of different correction methods on the measured myocardial TSC. METHODS: 23 Na MRI of four healthy subjects was conducted at a whole-body 7T MRI system using an oval-shaped 23 Na birdcage coil. Data acquisition was performed with a density-adapted 3D radial pulse sequence using a golden angle projection scheme. 1 H MRI data were acquired at a 3T MRI system to generate a myocardial mask. Retrospective cardiac and respiratory gating were used to reconstruct 23 Na MRI data in the diastolic phase and exhaled state. B0 and B1 inhomogeneity and partial volume (PV) effects were corrected. Relaxation times and TSC of ex vivo blood samples and calf muscle were determined. These values were used in the PV correction to estimate myocardial TSC, which was compared with the measured TSC of calf muscle. RESULTS: Without any correction the measured myocardial TSC was (54 ± 5) mM. The applied correction methods reduced these values by (48 ± 5)% to (29 ± 3) mM, where PV correction had the largest effect (reduction of (34 ± 1)%). Respiratory and cardiac motion gating decreased the concentrations by (11 ± 1)%. With the applied setup, the corrections of B0 and B1 inhomogeneity (reduction of (3 ± 2)%) had negligible influences on TSC values. The resulting myocardial TSC was approximately 1.4-fold higher than the measured TSC of calf muscle tissue of the same healthy subjects ((20 ± 3) mM). CONCLUSION: For quantitative human cardiac 23 Na MRI several corrections are needed and ranked for our setup: PV correction, respiratory and cardiac gating, correction for B1 inhomogeneity effects.


Asunto(s)
Corazón/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Miocardio/química , Sodio/análisis , Adulto , Algoritmos , Femenino , Humanos , Masculino , Fantasmas de Imagen , Técnicas de Imagen Sincronizada Respiratorias , Procesamiento de Señales Asistido por Computador , Isótopos de Sodio/química
16.
J Magn Reson Imaging ; 49(6): 1723-1729, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30575214

RESUMEN

BACKGROUND: Oblique sagittal MRI sequences, orthogonal to the longitudinal axis of the brachial plexus, can reliably depict morphologic and signal abnormalities. However, nerve visualization may be obscured by ghosting artifact from periodic respiratory motion. Respiratory triggering (RT) with a thoracoabdominal bellows can reduce ghosting artifact, but it is not routinely used for brachial plexus MRI. Furthermore, the efficacy of prospective RT for brachial plexus imaging has not yet been reported. PURPOSE: To compare brachial plexus MRI sequences acquired with and without respiratory triggering. STUDY TYPE: Prospective. SUBJECTS: Five volunteers and 20 patients were included. Each subject was imaged with and without RT during the same session. FIELD STRENGTH/SEQUENCE: Proton density or T2 -weighted Dixon fat suppressed sequences were obtained at 3.0T using receive-only 16-channel flexible array coils. ASSESSMENT: Three musculoskeletal radiologists blindly evaluated each sequence using subjective scoring criteria for ghosting artifact, nerve conspicuity, and diagnostic confidence. Nerve conspicuity scores at three distinct plexus levels were summed to calculate an overall image quality score. STATISTICAL TESTS: Marginal proportional odds logistic regression models were used to compare all scores between RT and non-RT. Gwet's agreement coefficient was used to assess interobserver and intraobserver reliability. RESULTS: Mean scan time per sequence increased from 4:25 minutes (95% confidence interval [CI], 4:02-4:49 min) with non-RT to 6:09 minutes (95% CI, 5:42-6:35 min) with RT. RT reduced ghosting artifact (odds ratio [OR] = 0.21, 95% CI: 0.09-0.46, P < 0.001), improved overall image quality (OR = 4.88, 95% CI: 2.18-10.95, P < 0.001), and increased diagnostic confidence (OR = 3.72, 95% CI: 1.61-8.63, P = 0.002) for all readers. Interobserver agreement for ghosting artifact and image quality was substantial to almost perfect (AC2 = 0.74-0.85). Interobserver agreement for all other scores was moderate to almost perfect (AC2 = 0.61-0.82). Intraobserver agreement was substantial to almost perfect for all parameters (AC2 = 0.76-1.0). DATA CONCLUSION: Prospective RT with bellows can effectively minimize ghosting artifact and improve image quality for brachial plexus MRI within clinically optimal acquisition times. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 2.


Asunto(s)
Plexo Braquial/diagnóstico por imagen , Imagen por Resonancia Magnética , Adulto , Artefactos , Femenino , Humanos , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Movimiento (Física) , Variaciones Dependientes del Observador , Estudios Prospectivos , Respiración , Relación Señal-Ruido , Adulto Joven
17.
J Appl Clin Med Phys ; 20(1): 258-264, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30597762

RESUMEN

The purpose of this study was to provide periodic quality assurance (QA) methods for respiratory-gated proton beam with a range modulation wheel (RMW) and to clarify the characteristics and long-term stability of the respiratory-gated proton beam. A two-dimensional detector array and a solid water phantom were used to measure absolute dose, spread-out Bragg peak (SOBP) width and proton range for monthly QA. SOBP width and proton range were measured using an oblique incidence beam to the lateral side of a solid water phantom and compared between with and without a gating proton beam. To measure the delay time of beam-on/off for annual QA, we collected the beam-on/off signals and the dose monitor-detected pulse. We analyzed the results of monthly QA over a 15-month period and investigated the delay time by machine signal analysis. The dose deviations at proximal, SOBP center and distal points were -0.083 ± 0.25%, 0.026 ± 0.20%, and -0.083 ± 0.35%, respectively. The maximum dose deviation between with and without respiratory gating was -0.95% at the distal point and other deviations were within ±0.5%. Proximal and SOBP center doses showed the same trend over a 15-month period. Delay times of beam-on/off for 200 MeV/SOBP 16 cm were 140.5 ± 0.8 ms and 22.3 ± 13.0 ms, respectively. Delay times for 160 MeV/SOBP 10 cm were 167.5 ± 15.1 ms and 19.1 ± 9.8 ms. Our beam delivery system with the RMW showed sufficient stability for respiratory-gated proton therapy and the system did not show dependency on the energy and the respiratory wave form. The delay times of beam-on/off were within expectations. The proposed QA methods will be useful for managing the quality of respiratory-gated proton beams and other beam delivery systems.


Asunto(s)
Neoplasias/radioterapia , Fantasmas de Imagen , Terapia de Protones/métodos , Garantía de la Calidad de Atención de Salud/normas , Planificación de la Radioterapia Asistida por Computador/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Humanos , Método de Montecarlo , Dosificación Radioterapéutica , Dispersión de Radiación
18.
J Appl Clin Med Phys ; 20(6): 194-198, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31055870

RESUMEN

The case of a 50-year-old man affected by a rhabdomiosarcoma metastatic lesion in the left flank Is reported. The patient was addressed to 50.4 Gy radiotherapy with concomitant chemotherapy in order to locally control the lesion. A Tri-60-Co magnetic resonance hybrid radiotherapy unit was used for treatment delivery and a respiratory gating protocol was applied for the different breathing phases (Free Breathing, Deep Inspiration Breath Hold and Final Expiration Breath Hold). Three intensity modulated radiation therapy (IMRT) plans were calculated and Final Expiration Breath Hold plan was finally selected due to the absence of PTV coverage differences and better organs at risk sparing (i.e. kidneys). This case report suggests that organs at risk avoidance with MRI-guided respiratory-gated Radiotherapy is feasible and particularly advantageous whenever sparing the organs at risk is of utmost dosimetric or clinical importance.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Órganos en Riesgo/efectos de la radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Guiada por Imagen/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Rabdomiosarcoma/radioterapia , Neoplasias Torácicas/radioterapia , Contencion de la Respiración , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Rabdomiosarcoma/patología , Neoplasias Torácicas/secundario
19.
J Appl Clin Med Phys ; 20(1): 37-42, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30387271

RESUMEN

This study reports the commissioning methodology and results of a respiratory gating system [AZ - 733 V/733 VI (Anzai Medical Co., Japan)] using a pressure sensor in carbon-ion scanning radiotherapy. Commissioning includes choosing a location and method for pressure sensor installation, delay time measurement of the system, and the final flow test. Additionally, we proposed a methodology for the determination of a threshold level of generating an on/off gate for the beam to the respiratory waveform, which is important for clinical application. Regarding the location and method for installation of the pressure sensor, the actual person's abdomen, back of the body position, and supine/prone positioning were checked. By comparing the motion between the pressure sensor output and the reference LED sensor motion, the chest rear surface was shown to be unsuitable for the sensor installation, due to noise in the signal caused by the cardiac beat. Regarding delay time measurement of the system, measurements were performed for the following four steps: (a). Actual motion to wave signal generation; (b). Wave signal to gate signal generation; (c). Gate signal to beam on/off signal generation; (d). Beam on/off signal to the beam irradiation. The total delay time measured was 46 ms (beam on)/33 ms (beam off); these were within the prescribed tolerance time (<100 ms). Regarding the final flow test, an end-to-end test was performed with a patient verification system using an actual carbon-ion beam; the respiratory gating irradiation was successfully performed, in accordance with the intended timing. Finally, regarding the method for determining the threshold level of the gate generation of the respiration waveform, the target motion obtained from 4D-CT was assumed to be correlated with the waveform obtained from the pressure sensor; it was used to determine the threshold value in amplitude direction.


Asunto(s)
Algoritmos , Radioterapia de Iones Pesados/instrumentación , Neoplasias Pulmonares/radioterapia , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Humanos , Presión , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Respiración
20.
J Xray Sci Technol ; 27(6): 1071-1086, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31476194

RESUMEN

The recent advancements in radiotherapy technologies have made delivery of the highly conformal dose to the target volume possible. With the increasing popularity of delivering high dose per fraction in modern radiotherapy schemes such as in stereotactic body radiotherapy and stereotactic body ablative therapy, high degree of treatment precision is essential. In order to achieve this, we have to overcome the potential difficulties caused by patient instability due to immobilization problems; patient anxiety and random motion due to prolonged treatment time; tumor deformation and baseline shift during a treatment course. This is even challenging for patients receiving radiotherapy in the chest and abdominal regions because it is affected by the patient's respiration which inevitably leads to tumor motion. Therefore, monitoring of intrafractional motion has become increasingly important in modern radiotherapy. Major intrafractional motion management strategies including integration of respiratory motion in treatment planning; breath-hold technique; forced shallow breathing with abdominal compression; respiratory gating and dynamic real-time tumor tracking have been developed. Successful intrafractional motion management is able to reduce the planning target margin and ensures planned dose delivery to the target and organs at risk. Meanwhile, the emergency of MRI-linear accelerator has facilitated radiation-free real-time monitoring of soft tissue during treatment and could be the future modality in motion management. This review article summarizes the various approaches that deal with intrafractional target, organs or patient motion with discussion of their advantages and limitations. In addition, the potential future advancements including MRI-based tumor tracking are also discussed.


Asunto(s)
Movimiento (Física) , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Humanos , Imagen por Resonancia Magnética , Neoplasias/radioterapia , Aceleradores de Partículas , Radioterapia Guiada por Imagen , Respiración