BMC Musculoskelet Disord ; 25(1): 336, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38671454

RESUMEN

BACKGROUND: An optimized fit of the tibial component to the resection platform and correct rotational alignment are critical for successful total knee arthroplasty (TKA). However, there remains controversy regarding the superiority of symmetric tibial component versus asymmetric tibial component. The objective of this systematic review and meta-analysis was to evaluate the current evidence for comparing the coverage and rotation of asymmetrical and symmetrical tibial component. METHODS: We searched potentially relevant studies form PubMed, Web of science, Embase, Cochrane Central Register of Controlled Trials (CENTRAL), and China National Knowledge Infrastructure (CNKI), up to 1 March 2023. Data extraction and quality assessment were performed by two independent reviewers. Meta-analysis was conducted using Review Manager 5.4. RESULTS: Sixteen articles were identified. Compared to symmetric tibial component, asymmetric tibial component increased the coverage of the proximal tibial cut surface (MD, -2.87; 95%CI, -3.45 to -2.28; P < 0.00001), improved the prevalence of tibial baseplate underhang (OR, 0.16; 95%CI, 0.07 to 0.33; P < 0.00001) and malrotation (OR, 0.13; 95%CI, 0.02 to 0.90; P = 0.04), and reduced the degree of tibial component rotation (MD, -3.11; 95%CI, -5.76 to -0.47; P = 0.02). But there was no statistical significance for improving tibial baseplate overhang (OR, 0.58; 95%CI, 0.08 to 3.97; P = 0.58). Additionally, no revision had occurred for the two tibial components in the included studies. CONCLUSION: The current evidence shows asymmetric tibial component offer advantages in terms of coverage and rotation compared with symmetric tibial component in TKA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Articulación de la Rodilla , Prótesis de la Rodilla , Tibia , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Artroplastia de Reemplazo de Rodilla/instrumentación , Tibia/cirugía , Articulación de la Rodilla/cirugía , Rotación , Diseño de Prótesis , Resultado del Tratamiento , Osteoartritis de la Rodilla/cirugía , Rango del Movimiento Articular
2.
J Arthroplasty ; 39(8S1): S256-S262, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38604279

RESUMEN

BACKGROUND: Tibial bone defects are commonly encountered in revision total knee arthroplasty (rTKA) and can be managed with metaphyseal cones or sleeves. Few studies have directly compared tibial cones and sleeves in rTKA, and none have limited this comparison to the most severe tibial defects. The purpose of this study was to evaluate and compare the outcomes of metaphyseal cones and sleeves for tibial reconstruction in rTKA regarding implant fixation and clinical outcomes. METHODS: A retrospective review was conducted on patients undergoing rTKA in which metaphyseal cones or sleeves were utilized for addressing metaphyseal bone loss (34 cones and 18 sleeves). Tibial bone loss was classified according to the Anderson Orthopaedic Research Institute bone defect classification, with types 2B and 3 being included. Patient-reported outcomes and postoperative complications were collected, and a radiographic evaluation of osseointegration or loosening was performed. RESULTS: There were 52 knees included (34 cones, 18 sleeves), with a median follow-up of 41.0 months. All-cause implant survival was 100% at 2 years and 96% (95% confidence interval: 76 to 99%) at 4 years, with 98% of tibial components demonstrating osseointegration at the final follow-up. During follow-up, there were a total 11 revisions, of which 1 sleeve was revised secondary to implant loosening. Tibial sleeves had a higher risk of revision compared to tibial cones (P < .01), and sleeves fixed with a hybrid technique were more likely to need revision than cones fixed by the same method (P = .01). CONCLUSIONS: Porous metaphyseal tibial cones and tibial metaphyseal sleeves both performed well at a 41-month median follow-up with no difference in aseptic survivorship between the 2 constructs. Both demonstrate high rates of osseointegration, low rates of aseptic failure, and significant improvement in Knee Society Scores in patients with severe tibial defects in rTKA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Reoperación , Tibia , Humanos , Estudios Retrospectivos , Femenino , Masculino , Artroplastia de Reemplazo de Rodilla/instrumentación , Artroplastia de Reemplazo de Rodilla/métodos , Anciano , Tibia/cirugía , Tibia/diagnóstico por imagen , Persona de Mediana Edad , Oseointegración , Resultado del Tratamiento , Falla de Prótesis , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/fisiopatología , Anciano de 80 o más Años , Estudios de Seguimiento
3.
J Arthroplasty ; 39(8S1): S174-S182, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38401608

RESUMEN

BACKGROUND: Obesity can be a source of higher failure rates and inferior clinical outcomes after total knee arthroplasty (TKA). The aim of this study was to compare outcomes, failure rates, and stress distributions of TKA in obese patients using a short, long, or no tibial stem. METHODS: A matching process based on the type of stem used and the age allowed included 180 patients who had a body mass index (BMI) > 30 and underwent a TKA between January 2010 and December 2019, with a minimum follow-up of 2 years. They were classified as moderately obese (MO: 30 < BMI < 35, N = 90) and severely obese (SO: BMI > 35, N = 90). For each, 3 subgroups were defined: thirty patients received a 30 mm short stem (SS), thirty received a 100 mm long stem (LS), and thirty received no stem (NS). Patients were assessed preoperatively and postoperatively using the Knee Society Score (KSS). A finite element model was developed to evaluate the biomechanical effects of the tibial stem on stress distribution in the subchondral bone based on BMI. RESULTS: The SS patients had significantly higher postoperative KSS knee score [MO: 88.9 (SS) versus 79 (LS) versus 80.6 (NS); SO: 84.5 versus 72.4 versus 78.2] (P < .0001) and function score [MO: 90.4 (SS) versus 78.4 (LS) versus 68.5 (NS); SO: 85.5 versus 73 versus 61.8] (P < .0001) compared to LS and NS patients. The biomechanical study demonstrated a BMI-dependent increase in stress in the subchondral bone in contact with the tibial components. These stresses were mainly distributed at the tibial cut for NS and along the stem for SS and LS. CONCLUSIONS: A short, cemented tibial stem offers better functional outcomes without increasing failure rates compared to a longer stem during primary TKA in a population of obese patients at two-year follow-up. A short tibial stem does not lead to increased stress compared to an LS, at least for certain BMI categories.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Obesidad , Tibia , Humanos , Masculino , Femenino , Anciano , Persona de Mediana Edad , Obesidad/complicaciones , Estudios de Seguimiento , Fenómenos Biomecánicos , Tibia/cirugía , Resultado del Tratamiento , Índice de Masa Corporal , Diseño de Prótesis , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiopatología , Falla de Prótesis , Osteoartritis de la Rodilla/cirugía , Análisis de Elementos Finitos , Estudios Retrospectivos
4.
Arch Orthop Trauma Surg ; 144(1): 347-355, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37743356

RESUMEN

INTRODUCTION: Few information has been published on the survival of unicompartmental knee arthroplasty (UKA) and fixed-bearing tibial components. The aim of this study is to analyze if UKA survival varies according to UKA model used and to analyze the possible risk factors for UKA revision. MATERIALS AND METHODS: A retrospective study analyzing 301 UKAs (ACCURIS, all-polyethylene tibial component, 152; Triathlon PKR, metal-backed tibial component, 149) was performed. Demographic parameters as well as implant survival and cause of prosthetic revision were analyzed. The Kaplan-Meier survival analysis, the log-rank test and the Cox multiple regression were used for the analysis. RESULTS: Average follow-up was 8.1 ± 3.08-years. Average age was 68.1 ± 8.6-years; 70.4% of subjects were women. The ACCURIS UKA group had a UKA revision rate higher compared to the Triathlon PKR group (16/152, 10.6% vs 5/149, 3.4%, respectively; p < 0.001). The main cause of prosthetic revision was aseptic loosening (5/21, 23.8%). All aseptic loosening cases and tibial component collapse were reported with the ACCURIS UKA group. Overall UKA survival was 98.01% (95% CI 95.62-99.1) at 1-year, 94.27% (95% CI 90.95-96.4) at 5-years and 92.38% (95% CI 88.48-94.99) at 10-years' follow-up. There were no differences in the Kaplan-Meier survival curves regarding operated side or affected tibiofemoral compartment (log-rank test = 0.614 and 0.763, respectively). However, Kaplan-Meier survival curve according to UKA model used was different (log-rank test = 0.033). The metal-backed component appeared to be a protector factor for UKA revision when adjusted for age, sex, operated side, and affected tibiofemoral compartment (Hazard Ratio 0.32, p = 0.031). CONCLUSION: Fixed-bearing UKAs showed excellent mid- and long-term survival rates. Aseptic loosening is the main cause of implant failure. PKR group (metal-backed component) seem to be a protector factor to UKA revision when it was compared with ACCURIS UKA group (all-polyethylene tibial component).


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Artroplastia de Reemplazo de Rodilla/efectos adversos , Prótesis de la Rodilla/efectos adversos , Estudios Retrospectivos , Reoperación/efectos adversos , Falla de Prótesis , Polietileno , Metales , Osteoartritis de la Rodilla/cirugía , Resultado del Tratamiento , Articulación de la Rodilla/cirugía
5.
J Orthop Traumatol ; 25(1): 24, 2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38704499

RESUMEN

BACKGROUND: This retrospective medium-term follow-up study compares the outcomes of medial fixed-bearing unicompartmental knee arthroplasty (mUKA) using a cemented metal-backed (MB) or an all-polyethylene (AP) tibial component. MATERIALS AND METHODS: The database of our institution was mined for primary mUKA patients implanted with an MB or an AP tibial component (the MB-UKA and AP-UKA groups, respectively) from 2015 to 2018. We compared patient demographics, patient-reported outcome measures (PROMs), and motion analysis data obtained with the Riablo™ system (CoRehab, Trento, Italy). We conducted propensity-score-matching (PSM) analysis (1:1) using multiple variables. RESULTS: PSM analysis yielded 77 pairs of MB-UKA and AP-UKA patients. At 5 years, the physical component summary (PCS) score was 52.4 ± 8.3 in MB-UKA and 48.2 ± 8.3 in AP-UKA patients (p < 0.001). The Forgotten Joint Score (FJS-12) was 82.9 ± 18.8 in MB-UKAs and 73.4 ± 22.5 in AP-UKAs (p = 0.015). Tibial pain was reported by 7.8% of the MB-UKA and 35.1% of the AP-UKA patients (p < 0.001). Static postural sway was, respectively, 3.9 ± 2.1 cm and 5.4 ± 2.3 (p = 0.0002), and gait symmetry was, respectively, 92.7% ± 3.7 cm and 90.4% ± 5.4 cm (p = 0.006). Patient satisfaction was 9.2 ± 0.8 in the MB-UKA and 8.3 ± 2.0 in the AP-UKA group (p < 0.003). CONCLUSIONS: MB-UKA patients experienced significantly better 5-year static sway and gait symmetry outcomes than AP-UKA patients. Although the PROMs of the two groups overlapped, MB-UKA patients had a lower incidence of tibial pain, better FJS-12 and PCS scores, and were more satisfied.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Metales , Medición de Resultados Informados por el Paciente , Puntaje de Propensión , Diseño de Prótesis , Humanos , Estudios Retrospectivos , Masculino , Femenino , Artroplastia de Reemplazo de Rodilla/métodos , Anciano , Estudios de Seguimiento , Persona de Mediana Edad , Tibia/cirugía , Polietileno , Resultado del Tratamiento , Osteoartritis de la Rodilla/cirugía
6.
BMC Musculoskelet Disord ; 24(1): 650, 2023 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-37582754

RESUMEN

BACKGROUND: Traditionally, the size of total knee arthroplasty (TKA) components is predicted by preoperative radiographic templating, which is of limited accuracy. This study aimed to evaluate the role of demographic data and ankle volume in predicting implant size in TKA candidates. METHODS: In a retrospective study, 415 patients who underwent TKA at a single institution were included. The mean age of the patients was 67.5 ± 7.1 years. The mean BMI of the patients was 31.1 ± 4.7 kg/m2. TKA implants were Zimmer Biomet NexGen LPS-Flex Knee in all cases. The demographic data included age, sex, height, weight, BMI, ethnicity, and ankle volume. Ankle volume was assessed with the figure-of-eight method. Multivariate linear regression analysis was used for predicting factors of implant size. RESULTS: Multivariate linear regression analysis showed that the Sex (ß:1.41, P < 0.001), height (ß:0.058, P < 0.001), ankle volume (ß:0.11, P < 0.001), and Age (ß:0.017, P = 0.004) were significant predictors of tibial component size. Sex (ß:0.89, P < 0.001), height (ß:0.035, P < 0.001), and ankle volume(ß:0.091, P < 0.001) were significant predictors of femoral component size in the multivariate analysis. CONCLUSION: Demographic data, adjunct with the ankle volume, could provide a promising model for preoperative prediction of the size of tibial and femoral components in TKA candidates.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Persona de Mediana Edad , Anciano , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Estudios Retrospectivos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Tibia/cirugía
7.
Knee Surg Sports Traumatol Arthrosc ; 31(11): 4773-4781, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37516985

RESUMEN

PURPOSE: The Attune® total knee arthroplasty system was introduced in 2013 to address lingering issues of patient dissatisfaction. However, recent literature reports concerns of early tibial tray debonding. The aim of this study was to compare the incidence of radiolucent lines, survivorship and patient reported outcome-measures between the Attune® system and the well-established Triathlon® system. METHODS: This retrospective database review was conducted at a single institution in Cork, Ireland. All primary Attune® (N = 445) and Triathlon® (N = 285) systems implanted between 2015 and 2016 were reviewed. Radiolucent lines were assessed for those with a minimum two-year radiological follow-up (Attune® = 338; Triathlon® = 231). X-rays were taken post op, at 6 months, 2 years and 5 years. Radiolucent lines were documented using the Modern Knee Society Radiographic System. Five-year survival was assessed using Kaplan-Meier analysis with the Log Rank method to determine statistical significance. The Oxford Knee Score and EQ-5D-5L, were collected pre-op, at 6 months, 2 years and 5 years post-operatively and compared using the Kruskal-Wallis Test. RESULTS: The Attune® had a higher proportion of radiolucent lines at the tibial tray [87.1% (54/62) vs 61.4% (27/44); p = 0.001] and at the implant-cement interface [62.9% (39/62) vs 43.2% (19/44); p = 0.02]. Conversely, the Triathlon® had a higher proportion AT the femur [38.6% (17/44) vs 12.9% (8/62); p = 0.001] and at the cement-bone interface [56.8% (25/44) vs 37.1% (23/62); p = 0.02]. The overall frequency of radiolucent lines was similar in both the Attune® and Triathlon® groups [17.8%, (60/338) vs 17.7%, (41/231); p = 0.49]. There was no difference in revision-free survival analysis at 5 years (Attune® 97.8% vs Triathlon® 95.8%; p = 0.129). The Attune® performed better at 5 years in the Oxford Knee Score [Attune® = 42.6 (SD 5.2) vs Triathlon® = 41 (SD 6.4); p = 0.001] and in the EQ-5D [Attune® = 0.773 (SD 0.187) vs Triathlon® = 0.729 (SD 0.218); p = 0.013]. There was no difference at 5 years in the EQ-VAS [Attune® = 80.4 (SD 13.7) vs Triathlon® = 78.5 (SD 15.3); p = 0.25]. CONCLUSION: The Attune® system exhibited a higher incidence of  radiolucent lines at the tibial tray. However, this did not lead to decreased survivorship at medium term follow-up compared to the Triathlon®. Furthermore, improvements in patient reported outcomes modestly favoured the Attune® system. LEVEL OF EVIDENCE: III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Estudios Retrospectivos , Articulación de la Rodilla/cirugía , Radiografía , Diseño de Prótesis , Cementos para Huesos , Falla de Prótesis , Resultado del Tratamiento
8.
J Arthroplasty ; 38(6S): S157-S163, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37019318

RESUMEN

BACKGROUND: Several studies have reported negative results after total knee arthroplasty (TKA) in obese patients. This study aims to analyze the minimum 2-year outcomes in patients who have a body mass index (BMI) > 35 undergoing cemented TKA using an all-polyethylene tibial component (APTC) at a minimum of 2 years of follow-up. METHODS: We retrospectively studied 163 obese patients (192 TKAs) who underwent a primary cemented TKA using an APTC comparing the outcomes of 96 TKA patients who had a BMI > 35 to 39.9 (group A) with 96 patients who a TKA and a BMI ≥40 (group B). Median follow-up of groups A and B were 3.8 years and 3.5 years respectively (P = .02). Multiple regression analyses were performed to evaluate independent risk factors associated with complications. Kaplan-Meier survival curves were estimated, defining failure as the need for any further femoral or tibial revision surgery with implant removal, irrespective of the reason. RESULTS: There was no significant difference at the latest follow-up patient-reported outcomes between both groups. Survivorship, as defined by revision for any reason, was 99% for group A and 99% for group B (P = 1.00). There was 1 aseptic tibial failure in group A, and 1 septic failure in group B. Multiple regression analyses showed no significant associations between age (odds ratio [OR] = 1.00; P = .98; 95% confidence interval (CI) = 0.93 to 1.08), sex (OR = 1.38; P = .70; 95% CI = 0.26 to 7.25), BMI (OR = 1.00; P = .95; 95% CI = 0.87 to 1.16), and complication rate. CONCLUSION: At a median 3.7-year follow-up, the use of an APTC provided excellent outcomes and survivorship in patients who had Class 2 and Class 3 obesity. LEVEL OF EVIDENCE: Level III, therapeutic study.


Asunto(s)
Prótesis de la Rodilla , Humanos , Articulación de la Rodilla/cirugía , Índice de Masa Corporal , Polietileno , Estudios Retrospectivos , Falla de Prótesis , Obesidad/complicaciones , Obesidad/cirugía , Reoperación , Resultado del Tratamiento , Diseño de Prótesis
9.
J Arthroplasty ; 38(6): 1145-1150, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36878440

RESUMEN

BACKGROUND: The best antibiotic spacer for periprosthetic knee joint infection treatment is unknown. Using a metal-on-polyethylene (MoP) component provides a functional knee and may avoid a second surgery. Our study investigated complication rates, treatment efficacies, durabilities, and costs of MoP articulating spacer constructs using either an all-polyethylene tibia (APT) or a polyethylene insert (PI). We hypothesized that while the PI would cost less, the APT spacer would have lower complication rates and higher efficacies and durabilities. METHODS: A retrospective review evaluated 126 consecutive articulating knee spacer (64 APTs and 62 PIs) cases from 2016 to 2020 was performed. Demographic information, spacer components, complication rates, infection recurrence, spacer longevity, and implant costs were analyzed. Complications were classified as follows: spacer-related; antibiotic-related; infection recurrence; or medical. Spacer longevity was measured for patients who underwent reimplantation and for those who had a retained spacer. RESULTS: There were no significant differences in overall complications (P < .48), spacer-related complications (P = 1.0), infection recurrences (P = 1.0), antibiotic-related complications (P < .24), or medical complications (P < .41). Average time to reimplantation was 19.1 weeks (4.3 to 98.3 weeks) for APT spacers and 14.4 weeks (6.7 to 39.7 weeks) for PI spacers (P = .09). There were 31% (20 of 64) of APT spacers and 30% (19 of 62) of PI spacers that remained intact for an average duration of 26.2 (2.3 to 76.1) and 17.1 weeks (1.7 to 54.7) (P = .25), respectively, for patients who lived for the duration of the study. PI spacers cost less than APT ($1,474.19 versus $2,330.47, respectively; P < .0001). CONCLUSION: APT and PI tibial components have similar results regarding complication profiles and infection recurrence. Both may be durable if spacer retention is elected, with PI constructs being less expensive.


Asunto(s)
Artritis Infecciosa , Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Infecciones Relacionadas con Prótesis , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Prótesis de la Rodilla/efectos adversos , Tibia/cirugía , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Prótesis/cirugía , Infecciones Relacionadas con Prótesis/tratamiento farmacológico , Articulación de la Rodilla/cirugía , Resultado del Tratamiento , Antibacterianos/uso terapéutico , Artritis Infecciosa/cirugía , Reoperación/efectos adversos , Polietilenos , Estudios Retrospectivos
10.
Arch Orthop Trauma Surg ; 143(6): 3447-3455, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36264510

RESUMEN

PURPOSE: Bi-unicompartmental knee arthroplasty is a less invasive treatment than a total one, great advantage for the patient but more difficult for the surgeon because of the lower visibility during surgery; this can therefore lead to eventual small errors in cutting angles during the procedure. The aim of this study is to investigate the effects of these slight angle variations in terms of anterior-posterior slope for the lateral tibial tray. METHODS: The geometries of the bones were acquired and uncemented fixed bearing metal-back UKAs virtually implanted in a finite elements environment. The lateral component was implanted in six different antero-posterior slope configurations (from - 5° to + 5° respect to medial component). Material properties for implant, bones and soft tissues were taken from the literature. A vertical compressive force of 2000 N was applied in full-extended configuration on the femur. Von Mises stress distribution in proximal tibia, load/pressure/contact area repartitions between the medial and lateral compartments was extracted as outputs. RESULTS: Outcomes for 0° and - 3° configurations are acceptable, but the - 2° of slope configuration achieved the best ones in terms of stress on proximal tibia, load repartition, contact pressure distribution and shear component. Drastically different results are found for the ± 5° configurations, presenting a level of unbalancing often associated with weak stability and failure over time. CONCLUSIONS: Slight errors can happen during the surgery: performing the cut aiming to slightly posterior slopes during the surgery helps to minimize the chances of obtaining positive slopes that could lead to an unstable implant.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Análisis de Elementos Finitos , Tibia/cirugía , Fémur/cirugía , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía
11.
Knee Surg Sports Traumatol Arthrosc ; 30(4): 1220-1230, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33825909

RESUMEN

PURPOSE: Tibial plateau fractures are serious complications of Oxford mobile-bearing unicompartmental knee arthroplasty (OUKA). This study examined where the fracture lines arises and evaluated the keel-cortex distances (KCDs) using three-dimensional computed tomography (3D-CT) and the effects of technical error (assessed by tibial component positions) and proximal tibial morphology on the KCDs. METHODS: This retrospective study included 217 OUKAs with cementless tibial components. Fifteen patients had tibial fractures after surgery. Anterior and posterior KCDs and fracture line origins were assessed using 3D-CT postoperatively. Proximal tibial morphology was assessed using the medial eminence line (MEL), which runs parallel to the tibial axis and passes through the tip of the medial intercondylar eminence of the tibia on long-leg anteroposterior radiograph. Knees had overhanging medial tibial condyle if the MEL passed medially to the medial tibial cortex. KCDs were compared between patients with/without fractures. Tibial component positions were evaluated, considering effects of tibial morphologies and component positions on fracture prevalence and KCDs. RESULTS: Fracture lines were found between the keel and posterior cortex in 12/15 patients. Posterior KCDs were significantly shorter in patients with fractures than in patients without (2.7 ± 1.6 mm vs 5.2 ± 1.7 mm, P < 0.001). Patients with medial overhanging condyles were more likely to have fracture (10/51 vs 5/166, P < 0.001) and had significantly shorter posterior KCD than those without (3.6 ± 1.5 mm vs 5.5 ± 1.8 mm, P < 0.001). Patients with tibial component that was set too medial, low, and valgus had higher rates of fracture than those without (7/39 vs 8/178, P = 0.008). Medial (r = 0.30, P < 0.001), low (r = -0.33, P < 0.001), and valgus implantations (r = 0.35, P < 0.001) of tibial components were related to shorter posterior KCDs. CONCLUSION: Short posterior KCD after OUKA is a risk factor for postoperative tibial fracture. Patients with either malposition of the tibial component (too medial, low, and valgus) and/or a medial overhanging condyle exhibit a shorter distance of posterior KCD and higher rate of fracture. LEVEL OF EVIDENCE: Level III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Fracturas de la Tibia , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla/efectos adversos , Osteoartritis de la Rodilla/complicaciones , Osteoartritis de la Rodilla/cirugía , Estudios Retrospectivos , Tibia/anatomía & histología , Tibia/diagnóstico por imagen , Tibia/cirugía , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/etiología , Fracturas de la Tibia/cirugía
12.
Knee Surg Sports Traumatol Arthrosc ; 30(8): 2768-2775, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34175990

RESUMEN

PURPOSE: The purpose of this retrospective study was to evaluate the effect of varus alignment of the tibial component on the outcomes with a minimum follow-up of 10 years. The hypothesis was that varus alignment of the tibial component might not affect the outcomes and survival of a neutrally aligned primary TKA. METHODS: A matched case-control study was designed between 66 patients with varus alignment of the tibial component and 66 with neutral alignment with a minimum follow-up of 10 years. Functional outcome was assessed with the knee surgery scores (KSS) and reduced Western Ontario and MacMaster Universities questionnaire (WOMAC). Patient satisfaction was evaluated by a 0-10 visual analog scale. Radiological evaluation was performed at early postoperative and at final follow-up. RESULTS: The mean follow-up was 11.9 (SD 2.6) years for both groups. The mean postoperative proximal tibial angle in the varus group was 85.0° (SD 0.9) and 88.8° (SD 0.9) in control group. At the final follow-up, there were no significant differences in KSS, WOMAC, range of motion or patient satisfaction. There were no differences in the coronal anatomical alignment of the TKA between groups. Revision of TKA was performed in four knees in the varus group, and one in control group, due to aseptic loosening of the tibial component in all cases. TKA survival at 10 years was not significantly different between groups. CONCLUSION: The alignment of the tibial component up to 7° varus did not negatively affect implant survival, patient satisfaction, and function of a well-aligned TKA, with a minimum postoperative follow-up of 10 years. LEVEL OF EVIDENCE: III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Estudios de Casos y Controles , Humanos , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Estudios Retrospectivos
13.
Knee Surg Sports Traumatol Arthrosc ; 30(8): 2654-2665, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33646370

RESUMEN

PURPOSE: To determine whether patient-specific instrumentation (PSI), computer-assisted surgery (CAS) or robot-assisted surgery (RAS) enable more accurate rotational alignment of the tibial baseplate in primary total knee arthroplasty (TKA) compared to conventional instrumentation, in terms of deviation from the planned target and the proportion of outliers from the target zone. METHODS: The authors independently conducted three structured electronic literature searches using the PubMed, Embase®, and Cochrane Central Register of Controlled Trials databases from 2007 to 2020. Studies were included if they compared rotational alignment of the tibial baseplate during TKA using conventional instrumentation versus PSI, CAS, and/or RAS, and reported deviation from preoperatively planned rotational alignment of the tibial baseplate in terms of absolute angles and/or number of outliers. Methodological quality of eligible studies was assessed by two researchers according to the Downs and Black Quality Checklist for Health Care Intervention Studies. RESULTS: Fifteen studies, that reported on 2925 knees, were eligible for this systematic review, of which 6 studies used PSI, and 9 used CAS. No studies were found for RAS. Of the studies that reported on angular deviation from preoperatively planned rotational alignment, most found smaller deviations using PSI (0.5° to 1.4°) compared to conventional instrumentation (1.0° to 1.6°). All studies that reported on proportions of outliers from a target zone (± 3°), found lower rates of outliers using PSI (0 to 22%) compared to conventional instrumentation (5 to 96%). Most studies reported smaller angular deviation from preoperatively planned rotational alignment using CAS (0.1° to 6.9°) compared to conventional instrumentation (1.1° to 7.8°). Of the studies that reported on proportions of outliers from a target zone (± 3°), most found fewer outliers using CAS (10 to 61%) compared to conventional instrumentation (17 to 78%). CONCLUSION: This systematic review and meta-analysis revealed that both CAS and PSI can improve the accuracy of rotational alignment of the tibial baseplate by decreasing angular deviation from the preoperatively planned target and reducing the proportion of outliers from the target zone. The clinical relevance is that PSI and CAS can improve alignment, though the thresholds necessary to grant better outcomes and survival remain unclear. LEVEL OF EVIDENCE: IV.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Cirugía Asistida por Computador , Humanos , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Rotación , Tibia/cirugía
14.
Medicina (Kaunas) ; 58(9)2022 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-36143888

RESUMEN

Background and Objectives: The tibial component alignment is an important issue for the longevity of total knee arthroplasty (TKA). The purpose of our study was to investigate the usefulness of proximal tibial references determined by pre-operative radiography and intraoperative C-arm-guided hip and ankle center marking for the extramedullary guided tibial cut in mild (<10°) and severe (≥10°) varus knee TKA. Materials and Methods: A total of 150 consecutive patients (220 cases) who underwent total knee arthroplasty who were recruited from July 2011 to April 2017 were reviewed retrospectively. Before surgery, the proximal tibial reference point and medio-lateral cut thickness difference were identified. Then, hip and ankle centers were checked using a C-arm intensifier intraoperatively. The hip−knee−ankle (HKA) alignment and medial proximal tibial angle (MPTA) were assessed pre-operatively and post-operatively. More than 3° varus or valgus of HKA alignment or tibial component angle was defined as an outlier. Results: Mean follow-up duration was 26.9 months. Among 220 cases, 111 cases are classified as mild varus group and 109 cases are classified as severe varus group. The HKA alignment is significantly improved (p < 0.001). The average tibial component angle after surgery is 90.1°. A total of 21 cases (9.5%) and 3 cases (1.4%) are classified as outliers of HKA alignment and MPTA, respectively. Among MPTA outliers, one case is in the mild varus group and two cases are in the in severe varus group (p = 0.62). Conclusion: Measurement of proximal tibial radiographic references and checking the C-arm-guided intraoperative hip and ankle center could be helpful to obtain the favorable coronal position of the tibial component in the extramedullary guided tibial cut.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/cirugía , Estudios Retrospectivos , Tibia/diagnóstico por imagen , Tibia/cirugía
15.
Eur J Orthop Surg Traumatol ; 32(2): 263-268, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33811527

RESUMEN

BACKGROUND: This study aims to determine the efficacy of both tranexamic acid (TXA) and tourniquet on the tibial cement mantle thickness in total knee arthroplasty (TKA). METHODS: We retrospectively reviewed the recorded data of patients with primary end-stage knee osteoarthritis who underwent TKA procedure during 2014-2016 at a single institution to evaluate the tibial cement mantle. Patients were categorized in two groups based on the use of tourniquet (groups 1 and 2). In addition, these groups were categorized into two different subgroups based on the use of TXA in groups 1 and 2 (group 1-A, B and group 2-A, B). Four zones at the tibial baseplate on the anteroposterior view and two zones on the lateral view were measured at the 4-6-week postoperative visit. RESULTS: A total of 28 patients (30 knees) were operated using tourniquet and TXA (group 1-A), 29 (30 knees) using tourniquet without TXA (group 1-B), 24 (28 knees) using TXA without tourniquet (group 2-A), and 38 (42 knees) without using TXA and tourniquet (group 2-B). Although a significant difference was found in the cumulative cement mantle penetration on postoperative X-rays between groups 1 and 2, no significant differences were found between groups A and B in both groups. CONCLUSIONS: This study reports that tourniquet use in TKA increased cement mantle penetration of the tibial component in primary TKA. The main strength of this study was that the TXA use alone exhibited no significant effect on the cement thickness.


Asunto(s)
Antifibrinolíticos , Artroplastia de Reemplazo de Rodilla , Ácido Tranexámico , Pérdida de Sangre Quirúrgica/prevención & control , Humanos , Hemorragia Posoperatoria , Estudios Retrospectivos , Tibia/diagnóstico por imagen , Tibia/cirugía , Torniquetes
16.
Knee Surg Sports Traumatol Arthrosc ; 29(10): 3164-3169, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32533222

RESUMEN

PURPOSE: Surgeons must rely on manufacturers to provide an appropriate distribution of total knee arthroplasty (TKA) sizes. There is a lack of literature regarding current appropriateness of tibial sizing schemes according to sex. As such, a study was devised assessing the adequacy of off-the-shelf tibial component size availability according to sex. METHODS: A search was conducted to identify all primary TKAs between July 2012 and June 2019 performed using a single implant. Baseline patient characteristics were collected (age, weight, height, BMI, and race). Two cohorts were created according to patient sex. Tibial sizes for each cohort were collected. Tibial component bar graph and histogram were created according to component sizes. Skewness and kurtosis were calculated for each distribution. Overhang was noted and measured radiographically. RESULTS: A total of 864 patients were identified, 38.7% males and 61.3% females. Most patients were Caucasian, and BMI was similar between cohorts. Tibial size distribution for males was as follows: 0.3% C, 4.8% D, 16.5% E, 40.1% F, 31.4% G, 6.9% H. Tibial size distribution for females was as follows: 30.8% C, 42.8% D, 23.0% E, 2.6% F, 0.8% G, 0.0% H. Histograms and normal curves demonstrated a fairly symmetric distribution of sizes for males (skewness = - 0.31, kurtosis = - 0.03). The distribution for females was positively skewed (skewness = 0.57, kurtosis = 0.12). Overall, overhang was noted in 16.6% of all size C tibias. CONCLUSIONS: The results of this study highlight an implant-specific discrepancy in size availability affecting female patients which could result in inferior outcomes. The authors urge manufacturers to critically assess current implant size distribution availability to ensure both genders are adequately, and equally represented. LEVEL OF EVIDENCE: IV.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Estudios de Cohortes , Femenino , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Masculino , Estudios Retrospectivos , Tibia/diagnóstico por imagen , Tibia/cirugía
17.
Knee Surg Sports Traumatol Arthrosc ; 29(3): 710-717, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32088805

RESUMEN

PURPOSE: This study aimed to investigate stress shielding of anatomical tibial components (ATCs) in comparison to conventional symmetric tibial components (STCs) in Korean patients which may be related to medial tibial bone loss. METHOD: 78 knees in 59 patients with ATCs (Persona™) and 74 knees in 58 patients with STCs (NexGen LPS-Flex™) were retrospectively reviewed. Radiographic parameters and clinical outcomes in both groups were compared. Logistic regression analysis was performed to identify risk factors for medial tibial bone loss. RESULTS: Medial tibial bone loss was significantly greater in the ATC group (1.6 ± 1.3 mm) than in the STC group (0.4 ± 0.8 mm) (p < 0.001). The ATC group showed a shorter distance between the distal metal tip and anteromedial cortex and higher invading into the sclerotic bone lesion (ISBL) than the STC group (p = 0.034 and p = 0.044, respectively). Multiple logistic regression analysis suggested ATC, a shorter distance to the anteromedial cortex, and the presence of ISBL as risk factors for medial tibial bone loss. The odds ratios of medial tibial bone loss according to type of prosthesis, distance to anteromedial cortex, and presence of ISBL were 6.25 (range 2.86-13.63, p < 0.001), 0.69 (range 0.51-0.93, p = 0.015), and 3.79 (range 1.56-9.21, p = 0.003), respectively. Notwithstanding, there was no difference in clinical outcomes between the two groups. CONCLUSION: In Korean patients, ATCs potentially causes greater medial tibial bone loss due to stress shielding than STCs. The design, however, does not yet appear to affect clinical outcomes at mid-term follow-up. LEVEL OF EVIDENCE: Retrospective cohort study, level III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Prótesis de la Rodilla , Osteoartritis de la Rodilla/cirugía , Tibia/cirugía , Anciano , Artroplastia de Reemplazo de Rodilla/efectos adversos , Resorción Ósea/epidemiología , Resorción Ósea/etiología , Femenino , Humanos , Rodilla/cirugía , Articulación de la Rodilla/cirugía , Modelos Logísticos , Masculino , Radiografía/métodos , República de Corea , Estudios Retrospectivos , Factores de Riesgo , Estrés Fisiológico , Tibia/fisiopatología , Resultado del Tratamiento
18.
J Arthroplasty ; 36(6): 2000-2005, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33632580

RESUMEN

BACKGROUND: High-viscosity (HV) bone cements have been formulated to offer potentially advantageous handling characteristics. However, alteration in the handling characteristics could influence implant fixation and survival. The primary objective of this study was to use radiostereometric analysis after total knee arthroplasty to assess the migration of the Triathlon tibial component fixed with HV cement (Simplex HV). METHODS: Twenty-three patients were followed for two years with radiostereometric analysis examinations at 6 visits. Migration was compared with published thresholds and with a control group from a previously published study from the same center using the same implants fixed with a medium viscosity cement. Inducible displacement was assessed, and Oxford 12 Knee Scores and satisfaction were recorded. RESULTS: Mean maximum total point motion migration reaching 0.40 mm (SD 0.16) at one year, and 0.41mm (SD 0.17) at two years, demonstrating a pattern of stable fixation, below published thresholds of acceptable migration, and not significantly different from the control group. One implant had continuous migration between 1 and 2 years but was clinically asymptomatic. Mean maximum total point motion inducible displacement measured at least one year postoperatively was 0.3 mm (SD 0.12). Mean Oxford 12 Knee Scores improved from 19 (SD 7) preoperatively to 42 (SD 8) 2 years postoperatively. CONCLUSIONS: The use of HV cement demonstrated an acceptable pattern of migration at 2 years, indicating low risk for aseptic loosening.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Cementos para Huesos , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Falla de Prótesis , Análisis Radioestereométrico , Tibia/cirugía , Viscosidad
19.
J Arthroplasty ; 36(7): 2536-2540, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33642111

RESUMEN

BACKGROUND: Tibial component loosening is one of the most common modes of failure in contemporary total knee arthroplasty (TKA). Limited literature is available on the outcomes of isolated tibial revision with retention of the cruciate retaining (CR) femoral component. The purpose of this study was to determine the results of isolated tibial revisions in CR TKA. METHODS: We identified 135 patients who underwent an isolated tibial revision after a primary CR TKA from our institutional registry between January 2007 and January 2017. The mean time between the primary and revision was 2.9 years (range 0.1-15.4). Revision with a press-fit stem was performed in 79 patients and 56 patients were revised with a fully cemented stem. Patients were evaluated at a minimum of two years using Knee Society Score, Knee Injury and Osteoarthritis Score for Joint Replacement, and radiography. Implant survivorship was determined using Kaplan-Meier survival analysis. RESULTS: At a mean follow-up of 5.1 years, there were six (4.4%) repeat revisions: three for periprosthetic infection (2.2%), two for instability (1.5%), and one for a fractured tibial stem (0.7%). The mean Knee Society Score and Knee Injury and Osteoarthritis Score for Joint Replacement increased from 51.6 and 56.1 preoperatively to 90.1 and 89.7 after surgery (P < .001). Survivorship free of repeat revision for any cause was 93.3% at 5 years, and aseptic revision survivorship was 95.8% at 5 years. No implants were radiographically loose. CONCLUSION: In patients with isolated tibial loosening and a well-fixed and well-positioned CR femoral component, isolated tibial revision provides excellent early to midterm implant survivorship and clinical outcomes with a low risk of instability and recurrent tibial loosening.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Artroplastia de Reemplazo de Rodilla/efectos adversos , Humanos , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla/efectos adversos , Diseño de Prótesis , Falla de Prótesis , Reoperación , Tibia/diagnóstico por imagen , Tibia/cirugía , Resultado del Tratamiento
20.
Int Orthop ; 45(12): 3063-3068, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-33877407

RESUMEN

INTRODUCTION: While considered a satisfactory solution, unicompartmental knee arthroplasty (UKA) still raises concerns in regard to its durability. These concerns particularly focus on the tibial component. This study aims to compare two different cemented tibial components belonging to the same UKA design: all polyethylene (AP) versus metal backed (MB), at a long-term follow-up. MATERIALS AND METHODS: We retrospectively reviewed 143 successive patients, 83 of which underwent surgery with AP tibial component UKA (37 males, 46 females), and 67 with MB ones (17 males, 50 females). All implants had the same prosthetic design (Accuris UKA, Smith e Nephew) with identical femoral oxinium component but different tibial component, AP or MB. The KSS and KOOS were assessed at a mean of 11.5-year follow-up and compared to pre-operative, post-operative, and one year evaluation. Statistical analysis was performed with SPSS for Mac (version 17.0). To assess potential statistically significant differences, t test was used and significance was set at P < 0.05. RESULTS: Final KSS at a mean of 11.5-year follow-up was 94.27 for the AP group and 96.12 for the MB ones. The final KOOS was 87 for AP components and 89.67 for the MB group. These results demonstrated, in all cases, statistically significant better results for MB tibial components compared to AP regarding KSS (P = 0.048), KOOS (P = 0.000), and pain (P = 0.014) at the 11.5-year follow-up. Survivorship for AP tibial component implants was 97.6%, while it was 89.5% for MB ones. CONCLUSION: While the survivorship rate has been found to be greater for AP implants compared to MB tibial components, this study reveals statistically better functional results according to KSS and KOOS, and pain, at a long-term follow-up for MB implants.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Artroplastia de Reemplazo de Rodilla/efectos adversos , Femenino , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Masculino , Osteoartritis de la Rodilla/cirugía , Polietileno , Estudios Retrospectivos , Tibia/cirugía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA