Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Sensors (Basel) ; 22(6)2022 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-35336555

RESUMEN

This study compares two methods to quantify the amplitude and frequency of head movements in patients with head tremor: one based on video-based motion analysis, and the other using a miniature wireless inertial magnetic motion unit (IMMU). Concomitant with the clinical assessment of head tremor severity, head linear displacements in the frontal plane and head angular displacements in three dimensions were obtained simultaneously in forty-nine patients using one video camera and an IMMU in three experimental conditions while sitting (at rest, counting backward, and with arms extended). Head tremor amplitude was quantified along/around each axis, and head tremor frequency was analyzed in the frequency and time-frequency domains. Correlation analysis investigated the association between the clinical severity of head tremor and head linear and angular displacements. Our results showed better sensitivity of the IMMU compared to a 2D video camera to detect changes of tremor amplitude according to examination conditions, and better agreement with clinical measures. The frequency of head tremor calculated from video data in the frequency domain was higher than that obtained using time-frequency analysis and those calculated from the IMMU data. This study provides strong experimental evidence in favor of using an IMMU to quantify the amplitude and time-frequency oscillatory features of head tremor, especially in medical conditions.


Asunto(s)
Movimientos de la Cabeza , Temblor , Humanos , Movimiento (Física) , Temblor/diagnóstico
2.
Osteoarthritis Cartilage ; 29(3): 346-356, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33422707

RESUMEN

OBJECTIVE: The knee adduction moment (KAM) can inform treatment of medial knee osteoarthritis; however, measuring the KAM requires an expensive gait analysis laboratory. We evaluated the feasibility of predicting the peak KAM during natural and modified walking patterns using the positions of anatomical landmarks that could be identified from video analysis. METHOD: Using inverse dynamics, we calculated the KAM for 86 individuals (64 with knee osteoarthritis, 22 without) walking naturally and with foot progression angle modifications. We trained a neural network to predict the peak KAM using the 3-dimensional positions of 13 anatomical landmarks measured with motion capture (3D neural network). We also trained models to predict the peak KAM using 2-dimensional subsets of the dataset to simulate 2-dimensional video analysis (frontal and sagittal plane neural networks). Model performance was evaluated on a held-out, 8-person test set that included steps from all trials. RESULTS: The 3D neural network predicted the peak KAM for all test steps with r2( Murray et al., 2012) 2 = 0.78. This model predicted individuals' average peak KAM during natural walking with r2( Murray et al., 2012) 2 = 0.86 and classified which 15° foot progression angle modifications reduced the peak KAM with accuracy = 0.85. The frontal plane neural network predicted peak KAM with similar accuracy (r2( Murray et al., 2012) 2 = 0.85) to the 3D neural network, but the sagittal plane neural network did not (r2( Murray et al., 2012) 2 = 0.14). CONCLUSION: Using the positions of anatomical landmarks from motion capture, a neural network accurately predicted the peak KAM during natural and modified walking. This study demonstrates the feasibility of measuring the peak KAM using positions obtainable from 2D video analysis.


Asunto(s)
Análisis de la Marcha , Osteoartritis de la Rodilla/fisiopatología , Adulto , Anciano , Puntos Anatómicos de Referencia , Fenómenos Biomecánicos , Estudios de Casos y Controles , Toma de Decisiones Clínicas , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Redes Neurales de la Computación , Osteoartritis de la Rodilla/terapia , Grabación en Video , Adulto Joven
3.
J Med Syst ; 45(12): 106, 2021 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-34731325

RESUMEN

Microsurgical skills of trainee surgeons have been subjectively evaluated due to the lack of technological tools. The objective of this investigation is to present the construct validity of the mitracks3D, which is a system designed to help in the objective evaluation of microsurgery trainees. To achieve this, a stereoscopic vision system records the 3D motion of two tweezers manipulated by surgeons during microsurgery training. Using motion analysis parameters (MAPs), quantitative information about their microsurgical skills and performance is obtained. For validation, 14 participants were enrolled and divided into two groups: expert microsurgeons (3 female, 2 male) and trainee surgeons (4 female, 5 male). The 3D motion tracking was acquired while the surgeons practiced with two training models: transferring objects and suture. Twelve MAPs were used to objective assessment the skill levels of each participant. Subsequent, statistical analysis was computed to compare the scores of both groups. Validation results showed statistically significant differences in 8 of the 12 MAPs and in 10 of the 12 MAPs using the transferring and the suturing models, respectively. The capability of mitracks3D to differentiate the performance of microsurgeons by analyzing their movements was shown. The mitracks3D system was successfully validated. With this system was possible to differentiate the psychomotor microsurgical skills between the two groups of surgeons. The mitracks3D system is a suitable device for the evaluation of microsurgical skills in a variety of surgical specialties that require it during the training of their residents.


Asunto(s)
Competencia Clínica , Microcirugia , Percepción de Profundidad , Femenino , Humanos , Masculino
4.
J Vasc Surg ; 69(5): 1482-1489, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30527939

RESUMEN

OBJECTIVE: Video motion analysis (VMA) uses fluoroscopic sequences to derive information on catheter and guidewire movement and is able to calculate two-dimensional catheter tip path length (PL) on the basis of frame-by-frame pixel coordinates. The objective of this study was to evaluate the effect of anatomic complexity on the efficiency of completion of defined stages of simulated carotid artery stenting as measured by VMA. METHODS: Twenty interventionists each performed a standardized easy, medium, and difficult carotid artery stenting case in random order on an ANGIO Mentor (Simbionix, Airport City, Israel) simulator. Videos of all procedures were analyzed using VMA software, and performance was expressed in terms of two-dimensional guidewire tip trajectory distance (PL). Comparisons of PL were used to identify differences in cannulation performance of the participants between the three cases of varying difficulty. The procedure was subdivided into four procedural phases: arch navigation, common carotid artery (CCA) cannulation, external carotid manipulation, and carotid lesion crossing. Comparisons of PL were used to identify differences in performance between the three cases of varying difficulty for each of the procedural phases. RESULTS: There were significant differences in PL in relation to anatomic complexity, with a stepwise increase in PL from easy to difficult cases: easy, median of 5000 pixels (interquartile range, 4075-5403 pixels); intermediate, 9059 (5974-14,553) pixels; difficult, 17,373 (11,495-26,594) pixels (P < .001). Similarly, during CCA cannulation, there was a stepwise increase in PL from easy to difficult cases: easy, 749 (603-1403) pixels; intermediate, 3274 (1544-8142) pixels; difficult, 8845 (5954-15,768) pixels (P < .001). There were no observed differences across the groups of anatomic difficulty for the phases of arch navigation, external carotid manipulation, and carotid lesion crossing. CONCLUSIONS: Increasing anatomic complexity leads to significant increases in PL of endovascular tools, in particular during CCA cannulation. This increase in tool movement may have a bearing on clinical outcome.


Asunto(s)
Angioplastia/educación , Estenosis Carotídea/terapia , Cateterismo Periférico , Competencia Clínica , Educación de Postgrado en Medicina/métodos , Destreza Motora , Entrenamiento Simulado , Adulto , Anciano , Anciano de 80 o más Años , Angioplastia/instrumentación , Estenosis Carotídea/diagnóstico por imagen , Cateterismo Periférico/instrumentación , Femenino , Humanos , Masculino , Estudios Prospectivos , Distribución Aleatoria , Índice de Severidad de la Enfermedad , Stents , Análisis y Desempeño de Tareas , Dispositivos de Acceso Vascular , Grabación en Video
5.
Behav Res Methods ; 49(2): 576-587, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-27130170

RESUMEN

We describe SwarmSight (available at https://github.com/justasb/SwarmSight ), a novel, open-source, Microsoft Windows software tool for quantitative assessment of the temporal progression of animal group activity levels from recorded videos. The tool utilizes a background subtraction machine vision algorithm and provides an activity metric that can be used to quantitatively assess and compare animal group behavior. Here we demonstrate the tool's utility by analyzing defensive bee behavior as modulated by alarm pheromones, wild-bird feeding onset and interruption, and cockroach nest-finding activity. Although more sophisticated, commercial software packages are available, SwarmSight provides a low-cost, open-source, and easy-to-use alternative that is suitable for a wide range of users, including minimally trained research technicians and behavioral science undergraduate students in classroom laboratory settings.


Asunto(s)
Conducta Animal , Programas Informáticos , Grabación en Video/métodos , Algoritmos , Animales , Factores de Tiempo
6.
Neurol Int ; 15(4): 1411-1422, 2023 Nov 29.
Artículo en Inglés | MEDLINE | ID: mdl-38132970

RESUMEN

The Clinical Rating Scale for Tremor (CRST) is commonly used to evaluate essential tremor (ET) during focused ultrasound (FUS) thalamotomy. However, it faces challenges such as the ceiling effect and test-retest variability. This study explored the utility of videographic motion analysis as an evaluation index for ET. Forty-three patients with ET performed postural tremor and line-drawing tasks recorded on video, and the data were analyzed using motion analysis software. The test-retest and inter-rater reliability, correlations with the CRST and tremor scores, and pre/post-FUS treatment comparisons were analyzed. The video motion analysis showed excellent test-retest and inter-rater reliability. In the postural tremor tasks, video parameter amplitude significantly correlated with the CRST and tremor scores. Similarly, for the line-drawing task, video parameter amplitude showed significant correlations with CRST and tremor scores, effectively addressing the ceiling effect. Regarding post-FUS treatment improvements, changes in the CRST and tremor scores were significantly associated with changes in video parameter amplitude. In conclusion, quantitative analysis of the video motion of ET enables precise evaluation of kinematic characteristics and effectively resolves the ceiling effect and test-retest variability. The video motion analysis score accurately reflected the tremor severity and treatment effects, demonstrating its high clinical utility.

7.
Front Physiol ; 9: 546, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29867582

RESUMEN

Beat to beat variability of cardiac tissue or isolated cells is frequently investigated by determining time intervals from electrode measurements in order to compute scale dependent or scale independent parameters. In this study, we utilize high-speed video camera recordings to investigate the variability of intervals as well as mechanical contraction strengths and relative contraction strengths with nonlinear analyses. Additionally, the video setup allowed us simultaneous electrode registrations of extracellular potentials. Sinoatrial node tissue under control and acetylcholine treated conditions was used to perform variability analyses by computing sample entropies and Higuchi dimensions. Beat to beat interval variabilities measured by the two recording techniques correlated very well, and therefore, validated the video analyses for this purpose. Acetylcholine treatment induced a reduction of beating rate and contraction strength, but the impact on interval variability was negligible. Nevertheless, the variability analyses of contraction strengths revealed significant differences in sample entropies and Higuchi dimensions between control and acetylcholine treated tissue. Therefore, the proposed high-speed video camera technique might represent a non-invasive tool that allows long-lasting recordings for detecting variations in beating behavior over a large range of scales.

8.
Mar Pollut Bull ; 124(2): 903-910, 2017 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-28341296

RESUMEN

Few studies to date have investigated the effects of ocean acidification on non-reef forming marine invertebrates with non-feeding larvae. Here, we exposed adults of the bryozoan Bugula neritina and their larvae to lowered pH. We monitored spawning, larval swimming, settlement, and post-settlement individual sizes at two pHs (7.9 vs. 7.6) and settlement dynamics alone over a broader pH range (8.0 down to 6.5). Our results show that spawning was not affected by adult exposure (48h at pH7.6), larvae swam 32% faster and the newly-settled individuals grew significantly larger (5%) at pH7.6 than in the control. Although larvae required more time to settle when pH was lowered, reduced pH was not lethal, even down to pH6.5. Overall, this fouling species appeared to be robust to acidification, and yet, indirect effects such as prolonging the pelagic larval duration could increase predation risk, and might negatively impact population dynamics.


Asunto(s)
Briozoos/fisiología , Agua de Mar/química , Animales , Fenómenos Biomecánicos , Briozoos/crecimiento & desarrollo , Concentración de Iones de Hidrógeno , Larva/crecimiento & desarrollo , Larva/fisiología , Reproducción , Natación
9.
Hand (N Y) ; 8(2): 123-31, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24426908

RESUMEN

BACKGROUND: Hand injuries affect a person's ability to engage successfully in activities of daily living (ADLs). Video motion capture (VMC) facilitates measurement of dynamic movement. No study to date has used VMC as a means of quantifying the simultaneous movement patterns of all joints of all digits of the hand during active purposeful movement. METHOD: The purpose of this study was to analyze all joints of all five digits during active completion of the lateral and pulp pinches. VMC data were collected from four participants during completion of two pinches. Joint angles were plotted to facilitate identification of movement patterns. RESULTS: Range of motion recorded in all joints with VMC, excluding flexion of the thumb carpometacarpal of both pinches, coincided with the normative goniometric data. Three phases were observed: initiation, preshaping, and pinch phases. Patterns of movement in all digits were identified for the two pinches. CONCLUSION: VMC is a feasible and valid method for objectively quantifying dynamic movement of multiple joints simultaneously. The results provide new insight to the dynamics of hand movement as well as a basis for subsequent evaluations of movement patterns performed in ADLs and instrumental ADLs.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA