RESUMEN
In our previous studies, we demonstrated that the Compton PET module, a layer structure PET detector with side readout, can provide high performance in terms of spatial/energy/timing resolution, as well as high gamma ray detection efficiency. In this study, we investigate how to translate the high performance of the detector module into good quality reconstructed tomographic images. This study is performed using GATE simulation, as well as with physical experiments. Similar detector geometry is used in the simulation and experiment: two identical 4-layer detector modules are placed with face to face distance of 56 mm. In the simulation study, each layer consists of a 1-mm-pitch pixelated crystal array. In the experimental study, each layer is a monolithic crystal, which is virtually binned into 1 mm2 cells to group single events according to the gamma ray interaction locations. A customized Derenzo phantom was placed between the two detector modules. By rotating the phantom using a motorized rotary stage, data along lines of response (LORs) at different angles were collected for reconstructing the tomographic image. The same reconstruction algorithm was used for both simulation and experimental studies. The results demonstrate that the simulation study could resolve 0.8 mm rods while the experimental study was able to resolve 1.0 mm rods.
RESUMEN
Selective laser sintering (SLS) is a prominent 3D printing modality that typically uses a polyamide (PA) powder as the substrate. One commercially available SLS material is known as PA2200, which is comprised of nylon 12 and titanium dioxide (TiO2) and is widely used to generate 3D-printed parts. Here, we report a unique optical photoluminescence (PL) characteristic of native, white PA2200, in which it yields a persistent, phosphorescence-type emission. An analysis of luminescence imaging data with emission measurements demonstrated that the anatase phase of the titanium dioxide additive is the source of the persistent PL properties. This characteristic of PA2200 enables advanced optical imaging applications, as demonstrated by luminescence imaging of an anatomical rat skeleton and a novel Derenzo-type phantom on a commercial image station. In summary, the light emission properties of PA2200 induced by the presence of anatase titanium dioxide open the door to a vast new array of complex optical applications, including the generation of imaging phantoms for training, calibration, and quality control.
RESUMEN
Positron emission tomography (PET) phantoms are used to calibrate PET scanners so that inter-scanner and inter-isotope comparison can be made between PET datasets. Hot rod style phantoms have a hole pattern, which is filled with a positron-emitting isotope and typically involves using two radioisotope reservoirs with the pattern created with channels in between. However, this configuration is difficult to fill and requires an excess of activity and volume. Here we present an alternative design, a phantom that is linearly filled-one channel at a time. The process of fabrication of prototypes of the design is described and PET images of the prototyped phantom are also shown for a variety of commonly used radioisotopes ((52)Mn, (64)Cu, (76)Br, (124)I). This design allows for a large reduction in isotope volume and required filling time making a quality assurance (QA) protocol safer, more efficient and less costly.