1.
J Surg Oncol ; 129(5): 995-999, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38221660

RESUMEN

BACKGROUND AND OBJECTIVES: With continued advances in treatment options, patients with endoprosthetic reconstruction are living longer and consequently relying upon their devices for a longer duration. Major causes of endoprosthesis failure include aseptic loosening and mechanical failure. In the setting of tumor resection, loss of bone stock and use of radiation therapy increase the risk for these complications. As such, considerations of remaining native bone and stem length and diameter may be increasingly important. We asked the following questions: (1) What was the overall rate of endoprosthesis failure at a minimum of 5-year follow-up? (2) Does resection length increase implant failure rates? (3) Does implant size and its ratio to cortical width of bone alter implant failure rates? METHODS: We retrospectively analyzed patient outcomes at a single institution between the years of 1999-2022 who underwent cemented endoprosthetic reconstruction at the hip or knee and identified 150 patients. Of these 150, 55 had a follow-up of greater than 5 years and were used for analysis. Radiographs of these patients at time of surgery were assessed and measured for resection length, bone diameter, stem diameter, and remaining bone length. Resection percentage, and stem to bone diameter ratios were then calculated and their relationship to endoprosthesis failure were analyzed. RESULTS: Patients in this cohort had a mean age of 55.8, and mean follow-up of 59.96 months. There were 78 distal femoral replacements (52%), 16 proximal femoral replacements (10.7%), and 56 proximal tibial replacements (37.3%). There were five patients who experienced aseptic loosening and six patients who experienced mechanical failure. Patients with implant failure had a smaller mean stem to bone diameter (36% vs. 44%; p = 0.002). A stem to bone diameter of 40% appeared to be a breaking point between success and failure in this series, with 90% of patients with implant failure having a stem: bone ratio less than 40%. Stem to bone ratio less than 40% increased risk for failure versus stems that were at least 40% the diameter of bone (6/19 [31.6%] vs. 0/36 [0%]; odds ratio 0.68; p < 0.001). Resection length did not appear to have an impact on the rates of aseptic loosening and mechanical failure in this series. CONCLUSIONS: Data from this series suggests a benefit to using stems with a larger diameter when implanting cemented endoprostheses at the hip or knee. Stems which were less than 40% the diameter of bone were substantially more likely to undergo implant failure.


Asunto(s)
Fémur , Falla de Prótesis , Humanos , Persona de Mediana Edad , Diseño de Prótesis , Estudios Retrospectivos , Fémur/diagnóstico por imagen , Fémur/cirugía , Tibia/diagnóstico por imagen , Tibia/cirugía , Reoperación , Resultado del Tratamiento
2.
J Arthroplasty ; 2023 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-38061400

RESUMEN

BACKGROUND: Total femur replacement (TFR) is used for primary reconstruction after extensive tumor resection or as a revision surgery due to prosthetic failure. Studies on TFR rates of failure and functional outcomes are scarce. The purpose of our study was to compare the modes of failure, amputation rates, and functional outcomes after TFR between oncologic and nononcologic patients. METHODS: We followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines were for this manuscript. Our study was registered on PROSPERO (413582). Quality assessment of all studies was performed using Strengthening the Reporting of Observational Studies in Epidemiology checklist. Endoprosthesis failure was assessed using the Henderson classification and functional outcomes using the Musculoskeletal Tumor Society score. Weighted means and standard deviations were calculated. RESULTS: Overall failure rate was similar between groups. Henderson type 4 failures were more common within the nononcologic group, while the others were more frequently found in the oncologic group. Overall amputation rate was higher in the oncologic group mainly due to type 5 failure. Amputations occurred mainly after type 4 and type 5 failures. Functional outcome was better within the oncologic group (70.5 versus 61.7, respectively; P < .001). CONCLUSIONS: Total femoral replacement in the oncologic and nononcologic group is associated with a high rate of failure (31% and 32.5%, respectively). Overall amputation rate was higher in the oncologic group mainly due to type 5 failure. Functional outcome was better within the oncologic group. LEVEL OF EVIDENCE: Level III.

3.
Materials (Basel) ; 16(9)2023 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-37176169

RESUMEN

We studied inflammatory and oxidative stress-related parameters and cytotoxic response of human umbilical vein endothelial cells (HUVEC) to a 24 h treatment with milled particles simulating debris involved in sandblasting of orthopedic implants (OI). We used different abrasives (corundum-(Al2O3), used corundum retrieved from removed OI (u. Al2O3), and zirconia/silica composite (ZrO2/SiO2)). Morphological changes were observed by scanning electron microscopy (SEM). Concentration of Interleukins IL-6 and IL-1ß and Tumor Necrosis Factor α (TNF)-α was assessed by enzyme-linked immunosorbent assay (ELISA). Activity of Cholinesterase (ChE) and Glutathione S-transferase (GST) was measured by spectrophotometry. Reactive oxygen species (ROS), lipid droplets (LD) and apoptosis were measured by flow cytometry (FCM). Detachment of the cells from glass and budding of the cell membrane did not differ in the treated and untreated control cells. Increased concentration of IL-1ß and of IL-6 was found after treatment with all tested particle types, indicating inflammatory response of the treated cells. Increased ChE activity was found after treatment with u. Al2O3 and ZrO2/SiO2. Increased GST activity was found after treatment with ZrO2/SiO2. Increased LD quantity but not ROS quantity was found after treatment with u. Al2O3. No cytotoxicity was detected after treatment with u. Al2O3. The tested materials in concentrations added to in vitro cell lines were found non-toxic but bioactive and therefore prone to induce a response of the human body to OI.