Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 173
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Proc Natl Acad Sci U S A ; 121(22): e2401656121, 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38787880

RESUMEN

Understanding the dynamics of electric-double-layer (EDL) charging in porous media is essential for advancements in next-generation energy storage devices. Due to the high computational demands of direct numerical simulations and a lack of interfacial boundary conditions for reduced-order models, the current understanding of EDL charging is limited to simple geometries. Here, we present a network model to predict EDL charging in arbitrary networks of long pores in the Debye-Hückel limit without restrictions on EDL thickness and pore radii. We demonstrate that electrolyte transport is described by Kirchhoff's laws in terms of the electrochemical potential of charge (the valence-weighted average of the ion electrochemical potentials) instead of the electric potential. By employing the equivalent circuit representation suggested by these modified Kirchhoff's laws, our methodology accurately captures the spatial and temporal dependencies of charge density and electric potential, matching results obtained from computationally intensive direct numerical simulations. Our network model provides results up to six orders of magnitude faster, enabling the efficient simulation of a triangular lattice of five thousand pores in 6 min. We employ the framework to study the impact of pore connectivity and polydispersity on electrode charging dynamics for pore networks and discuss how these factors affect the time scale, energy density, and power density of capacitive charging. The scalability and versatility of our methodology make it a rational tool for designing 3D-printed electrodes and for interpreting geometric effects on electrode impedance spectroscopy measurements.

2.
Sensors (Basel) ; 24(9)2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38732819

RESUMEN

In this paper, we present a novel three-dimensional (3D) coupled configuration of piezoelectric micromachined ultrasound transducers (pMUTs) by combing a curved and an annular diaphragm for transmit performance optimization in biomedical applications. An analytical equivalent circuit model (EQC) is developed with varied excitation methods to incorporate the acoustic-structure coupling of the curved and annular diaphragm-coupled pMUTs (CAC-pMUTs). The model-derived results align well with the reference simulated by the finite element method (FEM). Using this EQC model, we optimize the key design parameters of the CAC-pMUTs in order to improve the output sound pressure, including the width of the annular membrane, the thickness of the passive layer, and the phase difference of the driving voltage. In the anti-phase mode, the designed CAC-pMUTs demonstrate a transmit efficiency 285 times higher than that of single annular pMUTs. This substantial improvement underscores the potential of CAC-pMUTs for large array applications.

3.
Nano Lett ; 23(12): 5738-5745, 2023 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-37294577

RESUMEN

The operational stability of the blue quantum dot light-emitting diode (QLED) has been one of the most important obstacles to initialize its industrialization. In this work, we demonstrate a machine learning assisted methodology to illustrate the operational stability of blue QLEDs by analyzing the measurements of over 200 samples (824 QLED devices) including current density-voltage-luminance (J-V-L), impedance spectra (IS), and operational lifetime (T95@1000 cd/m2). The methodology is able to predict the operational lifetime of the QLED with a Pearson correlation coefficient of 0.70 with a convolutional neural network (CNN) model. By applying a classification decision tree analysis of 26 extracted features of J-V-L and IS curves, we illustrate the key features in determining the operational stability. Furthermore, we simulated the device operation using an equivalent circuit model to discuss the device degradation related operational mechanisms.

4.
Molecules ; 29(14)2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39064903

RESUMEN

For the purpose of predicting the state of health of already used lithium-ion batteries from 85 kWh electric vehicles, a simplified equivalent circuit model is utilized to estimate the electrochemical time constant from constant current discharge profiles. The grading process among as-obtained LIB cells is classified into three level types according to the remaining capacity and direct current resistance. Theoretically, the logarithmic equation describing cycling behavior is derived and utilized in the prediction of the state of health of the used cells. After the selection of the electrochemical time constant obtained from the best-fitting results in constant current discharge data, the suitable cycle number until the 20th cycle was selected for the prediction of the state of health after the 250th cycling data, which revealed that a narrow error range below 5% was for high and medium battery grades. Also, this error range became abruptly wider in lowest grade batteries, indicating that our proposed model for cycling behavior was highly useful in the prediction of the future state of health of the used batteries.

5.
Nanotechnology ; 34(15)2023 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-36595230

RESUMEN

To tackle the problem of the low output power of triboelectric nanogenerators (TENGs), the output characteristics of multiple TENGs in series and parallel were explored. An experimental device for multilayer TENGs was developed. Through the method of experimental modeling, the equivalent circuits and mathematical models in series and parallel are established respectively, and the working principle is expounded. The experiment found that when multiple TENGs are connected in parallel, the voltage, current, and output power can be regularly increased. When the TENGs are connected in series, the output power is only related to the performance of the first and last two triboelectric generators and has nothing to do with the number of series-connected TENGs. This finding has a certain reference value for the design of high-efficiency triboelectric nanogenerators.

6.
Sensors (Basel) ; 23(19)2023 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-37836910

RESUMEN

The use of piezoelectric transducers for internal dynamic pressure measurements in ammunition testing provides a significant advantage in the development and performance analysis of weapons and ammunition. Knowledge of the electrical characteristics of the dynamic pressure measurement chain, which includes the piezoelectric transducer and the charge amplifier, is a relevant condition for the design of interior ballistics pressure measurement systems. Thus, this study aims to characterize and model a piezoelectric transducer and its associated charge amplifier. First, the piezoelectric transducer was characterized using impedance analysis and modeled using a least squares curve-fitting tool, according to the Butterworth-Van Dyke model. Next, the charge amplifier was characterized through response analysis based on known inputs and modeled using LTSpice simulation techniques and the least squares curve-fit tool. Consequently, a measurement chain model is presented and simulated for two cases with different impulse signals. The first impulse signal was obtained from an interior ballistics computer simulation, and in the second case, it was considered the negative step signal characteristic of the calibration of piezoelectric transducers by means of dead weight. From the simulations, it was possible to verify the effectiveness of the model, which provided results with a low error in relation to the original pressure curve, and its applicability is demonstrated by the result of the simulation of the pressure variation in the calibration, where the attenuation of the signal can be visualized as the characteristic of the input curve changes.

7.
Sensors (Basel) ; 23(14)2023 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-37514930

RESUMEN

Improving the operational efficiency and optimizing the design of sound navigation and ranging (sonar) systems require accurate electrical equivalent models within the operating frequency range. The power conversion system within the sonar system increases power efficiency through impedance-matching circuits. Impedance matching is used to enhance the power transmission efficiency of the sonar system. Therefore, to increase the efficiency of the sonar system, an electrical-matching circuit is employed, and this necessitates an accurate equivalent circuit for the sonar transducer within the operating frequency range. In conventional equivalent circuit derivation methods, errors occur because they utilize the same number of RLC branches as the resonant frequency of the sonar transducer, based on its physical properties. Hence, this paper proposes an algorithm for deriving an equivalent circuit independent of resonance by employing multiple electrical components and particle swarm optimization (PSO). A comparative verification was also performed between the proposed and existing approaches using the Butterworth-van Dyke (BVD) model, which is a method for deriving electrical equivalent circuits.

8.
Sensors (Basel) ; 24(1)2023 Dec 25.
Artículo en Inglés | MEDLINE | ID: mdl-38202969

RESUMEN

Alterations in the dynamical properties of an atomic force microscope microcantilever beam system in tapping mode can appreciably impact its measurement precision. Understanding the influence mechanism of dynamic parameter changes on the system's motion characteristics is vital to improve the accuracy of the atomic force microscope in tapping mode (AFM-TM). In this study, we categorize the mathematical model of the AFM-TM microcantilever beam system into systems 1 and 2 based on actual working conditions. Then, we analyze the alterations in the dynamic properties of both systems due to external excitation variations using bifurcation diagrams, phase trajectories, Lyapunov indices, and attraction domains. The numerical simulation results show that when the dimensionless external excitation g < 0.183, the motion state of system 2 is period 1. When g < 0.9, the motion state of system 1 is period 1 motion. Finally, we develop the equivalent circuit model of the AFM-TM microcantilever beam and perform related software simulations, along with practical circuit experiments. Our experimental results indicate that the constructed equivalent circuit can effectively analyze the dynamic characteristics of the AFM-TM microcantilever beam system in the presence of complex external environmental factors. It is observed that the practical circuit simulation attenuates high-frequency signals, resulting in a 31.4% reduction in excitation amplitude compared to numerical simulation results. This provides an essential theoretical foundation for selecting external excitation parameters for AFM-TM cantilever beams and offers a novel method for analyzing the dynamics of micro- and nanomechanical systems, as well as other nonlinear systems.

9.
Sensors (Basel) ; 23(3)2023 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-36772212

RESUMEN

In this paper, a novel method is proposed to effectively reduce the size of a waveguide bandpass filter (BPF). Because the metallic cavities make the conventional waveguide end up with a large geometry, especially for high-order BPFs, very compact waveguide-type resonators having metamaterial zeroth-order resonance (WG ZOR) are designed on the cross section of the waveguide and substituted for the cavities. While the cavities are half-wavelength resonators, the WG ZOR is shorter than one-eighth of a wavelength. A substantial reduction in the size and weight of the waveguide filter is observed as the resonators are cascaded in series through coupling elements in the X-band that is much longer than that in K- or Ka-bands. The proposed metamaterial filter is realized as a 3D-printed structure to be lighter and thus more suitable for low earth orbit (LEO) satellites. An X-band of 7.25-7.75 GHz is chosen to verify the method as the passband with an attenuation of 40 dB at 7.00 GHz and 8.00 GHz as the roll-off in the stopband. The BPF is manufactured in two ways, namely the CNC-milling technique and metal coating-added 3D printing. The design is carried out with a geometrical parameter of not 10-2 mm but rather 10-1 mm, which is good for manufacturers but challenging for component designers. The measurement of the manufactured metal waveguide filters reveals that the passband has about ≤1 dB and ≤-15 dB as the insertion loss and the reflection coefficient, respectively, and the stopband has an attenuation of ≤-40 dB, which are in good agreement with the results of the circuit and the simulation. The proposed filter has a length of 14 cm as the eighth-order BPF, but the conventional waveguide is 20 cm as the seventh-order BPF for the same area of the cross section.

10.
Sensors (Basel) ; 23(4)2023 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-36850544

RESUMEN

Global and intercontinental networking relies on satellite communication. Its wireless communication system always has antennas and their feed assembly comprising waveguides. This makes the satellite payload heavy and costly. In this paper, a novel method is proposed to effectively reduce the size of a waveguide bandpass filter (BPF). Because the metallic cavities make the conventional waveguide end up with a large geometry, especially for high-order BPFs, very compact waveguide-type resonators having metamaterial zeroth-order resonance (WG-ZOR) are designed on the cross-section of the waveguide and substituted for the cavities. While the cavities are half-wavelength resonators, the WG-ZOR is shorter than one eighth of a wavelength. A substantial reduction in size and weight of the waveguide filter is observed as the resonators are cascaded in series through coupling elements in the X-band much longer than K- or Ka-band. An X-band of 7.25~7.75 GHz is chosen to verify the method as the passband with attenuation of 40 dB at 7.00 GHz and 8.00 GHz as the roll-off in the stopband. The BPF is manufactured using the CNC milling technique. The design is carried out with geometrical parameters, not of the level of 10 µm, but the level of 100 µm, which is good for manufacturers but a big challenge for component designers. The measurement of the manufactured metal waveguide filter reveals that the passband has about ≤1 dB and ≤-15 dB as insertion loss and reflection coefficient and the stopband has ≤-40 dB as attenuation, which are in good agreement with the results of the circuit and simulation. The proposed filter has a length of 3.5 λg as the eighth-order BPF, but the conventional waveguide is 5 λg as the seventh-order BPF for the same area of the cross-section. This metamaterial BPF is combined with a horn antenna. The filter enables the wide-band antenna to distinguish the band of transmission from that of noise suppression. This channel selectivity is obviously observed by the filter integrated antenna test.

11.
Molecules ; 28(8)2023 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-37110832

RESUMEN

The impacts on the morphological, electrical and hardness properties of thermoplastic polyurethane (TPU) plates using multi-walled carbon nanotubes (MWCNTs) as reinforcing fillers have been investigated, using MWCNT loadings between 1 and 7 wt%. Plates of the TPU/MWCNT nanocomposites were fabricated by compression molding from extruded pellets. An X-ray diffraction analysis showed that the incorporation of MWCNTs into the TPU polymer matrix increases the ordered range of the soft and hard segments. SEM images revealed that the fabrication route used here helped to obtain TPU/MWCNT nanocomposites with a uniform dispersion of the nanotubes inside the TPU matrix and promoted the creation of a conductive network that favors the electronic conduction of the composite. The potential of the impedance spectroscopy technique has been used to determine that the TPU/MWCNT plates exhibited two conduction mechanisms, percolation and tunneling conduction of electrons, and their conductivity values increase as the MWCNT loading increases. Finally, although the fabrication route induced a hardness reduction with respect to the pure TPU, the addition of MWCNT increased the Shore A hardness behavior of the TPU plates.

12.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 40(5): 886-893, 2023 Oct 25.
Artículo en Zh | MEDLINE | ID: mdl-37879917

RESUMEN

In this paper, the differences between air probe and filled probe for measuring high-frequency dielectric properties of biological tissues are investigated based on the equivalent circuit model to provide a reference for the methodology of high-frequency measurement of biological tissue dielectric properties. Two types of probes were used to measure different concentrations of NaCl solution in the frequency band of 100 MHz-2 GHz. The results showed that the accuracy and reliability of the calculated results of the air probe were lower than that of the filled probe, especially the dielectric coefficient of the measured material, and the higher the concentration of NaCl solution, the higher the error. By laminating the probe terminal, liquid intrusion could be prevented, to a certain extent, to improve the accuracy of measurement. However, as the frequency decreased, the influence of the film on the measurement increased and the measurement accuracy decreased. The results of the study show that the air probe, despite its simple dimensional design and easy calibration, differs from the conventional equivalent circuit model in actual measurements, and the model needs to be re-corrected for actual use. The filled probe matches the equivalent circuit model better, and therefore has better measurement accuracy and reliability.


Asunto(s)
Cloruro de Sodio , Reproducibilidad de los Resultados , Calibración
13.
Magn Reson Med ; 87(6): 2997-3010, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35092069

RESUMEN

PURPOSE: To protect patients from RF heating in MRI scan, this work proposes an accurate and patient-specific whole-body specific absorption rate (SAR) characterization method based on an equivalent circuit model. Compared to the standard pulse energy method defined in NEMA MS 8-2016, this method avoids the complexity of integrating flux loops and has the potential to be easily implemented in MRI scanners. THEORY AND METHODS: In this study, we use an equivalent parallel circuit to model the power distribution on the transmit coil and subject. The coil and subject equivalent resistances are fitted by the frequency response functions of reflection coefficient and are thereafter used to calculate the power ratio between them. To assess the accuracy of this method, we measured the subject absorbed power of 2 phantoms and 5 volunteers and compared it with the standard pulse energy method with flux loops. RESULTS: The resistances, resonant frequencies, and quality factors of the transmit coil are fitted with the equivalent circuit model in both unloaded and loaded conditions. Whole-body SAR of 5 volunteers is measured at 2 different landmarks. In addition, the relationship between SAR and the working frequencies of the transmit coil is measured and analyzed. The subject absorbed power measured by the proposed method demonstrates good accuracy (RMS error and maximum error of 3.77% and 9.47%, respectively) relative to the flux loop method. CONCLUSION: The equivalent circuit model-based method enables individualized, accurate, and simplified SAR characterization for clinical applications and research with moderate implementation complexity.


Asunto(s)
Imagen por Resonancia Magnética , Ondas de Radio , Calefacción , Humanos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen
14.
Appl Microbiol Biotechnol ; 106(3): 1097-1112, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35037996

RESUMEN

Impedance spectroscopy is used for the characterization of electrochemical systems as well as for the monitoring of bioprocesses. However, the data obtained using this technique allow multiple interpretations, depending on the methodology implemented. Hence, it is necessary to establish a robust methodology to reliably follow-up biomass in fermentations. In the present work, two methodological approaches, mainly used for the characterization of electrochemical systems, were employed to characterize and determine a frequency that allows the monitoring of biomass in Bacillus thuringiensis fermentations by impedance spectroscopy. The first approach, based on a conventional analysis, revealed a single distribution with a characteristic frequency of around 2 kHz. In contrast, the second approach, based on the distribution of relaxation times, gave three distributions (A, B, and C). The C distribution, found near 9 kHz, was more related to the microbial biomass than the distribution at 2 kHz using the equivalent circuits. The time course of the B. thuringiensis fermentation was followed; bacilli, spores, glucose, and acid and base consumption for pH were determined out of line; and capacitance at 9 kHz was monitored. The correlation between the time course data and the capacitance profile indicated that the monitoring of B. thuringiensis at 9 kHz mainly corresponds to extracellular activity and, in a second instance, to the cellular concentration. These results show that it is necessary to establish a robust and reliable methodology to monitor fermentation processes by impedance spectroscopy, and the distribution of relaxation times was more appropriate. KEY POINTS: • Application of impedance spectroscopy for bioprocess monitoring • Low-frequency monitoring of biomass in fermentations • Analysis of impedance data by two methodological approaches.


Asunto(s)
Bacillus thuringiensis , Espectroscopía Dieléctrica , Biomasa , Fermentación , Estudios de Seguimiento
15.
Sensors (Basel) ; 22(21)2022 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-36366274

RESUMEN

This research focuses on the load characteristics of piezoelectric transducers in the process of longitudinal vibration ultrasonic welding. We are primarily interested in the impedance characteristics of the piezoelectric transducer during loading, which is studied by leveraging the equivalent circuit theory of piezoelectric transducers. Specifically, we propose a cross-value mapping method. This method can well map the load change in ultrasonic welding to the impedance change, aiming to obtain an equivalent model of impedance and load. The least-squares strategy is used for parameter identification during data fitting. Extensive simulations and physical experiments are conducted to verify the proposed model. As a result, we can empirically find that the result from our model agrees with the impedance characteristics from the real-life data measured by the impedance meter, indicating its potential for real practice in controller research and transducer design.


Asunto(s)
Diseño Asistido por Computadora , Ultrasonido , Diseño de Equipo , Modelos Teóricos , Ultrasonografía , Transductores
16.
Sensors (Basel) ; 22(22)2022 Nov 12.
Artículo en Inglés | MEDLINE | ID: mdl-36433342

RESUMEN

A cymbal transducer has a simple structure consisting of a piezoceramic disk and metallic caps and has broadband characteristics when built as an array. The finite element method (FEM) is generally used to analyze the characteristics of acoustic transducers. However, the FEM requires a longer analysis time as the model becomes larger, which makes it limited and less efficient for analyzing the cymbal array. In this study, a new equivalent circuit with higher efficiency and accuracy, comparable to that of the FEM, was proposed to analyze the performance of cymbal arrays. The equivalent circuit for the array was constructed by connecting the equivalent circuits of individual cymbal transducers in parallel with a radiation impedance matrix that included both the self- and mutual radiation characteristics of the array. The validity of the new equivalent circuit was verified by measuring the transmitting voltage response of a cymbal array specimen and comparing it with that calculated using the circuit. The comparison confirmed the efficiency of the equivalent circuit in analyzing the characteristics of the cymbal array. The proposed equivalent circuit can facilitate the design of a large array of cymbal transducers.


Asunto(s)
Acústica , Transductores , Diseño de Equipo
17.
Sensors (Basel) ; 22(19)2022 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-36236698

RESUMEN

This paper presents a printed magnetic probe that can switch from broadband to tunable narrowband for near-field measurement. In the early design stage, we created a printed loop gap resonator as a magnetic reference sensor for the pre-compliance test in a band up to 6 GHz. Consequently, the results showed a good response in terms of the S11 and S21 parameters of the proposed probe compared with the commercial magnetic sensor XF-R 3-1. The source noise might spread among different frequency bands, making the broadband magnetic probe the closest choice for estimating the magnetic field in the near-field region. Unfortunately, broadband magnetic probes have lower sensitivity than narrowband ones. One of the solutions to get high sensitivity is to connect the LNA to the output of the passive magnetic sensor. This work proposes a novel method to solve this issue using a PIN diode to change the broadband status into a high sensitivity narrowband status and then tune this narrowband across the most critical applications such as 3.5 GHz, 3.75 GHz, 4.8 GHz, and 5.2 GHz with the help of a varactor diode. Compared to the broadband status, an improvement of more than 10 dB has been obtained across all these wireless bands. Furthermore, the proposed structure's isolation between the electrical and magnetic fields is about 13 dB.

18.
Sensors (Basel) ; 22(19)2022 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-36236777

RESUMEN

As the main power source of new energy electric vehicles, the accurate estimation of State of Charge (SOC) of Li-ion batteries is of great significance for accurately estimating the vehicle's driving range, prolonging the battery life, and ensuring the maximum efficiency of the whole battery pack. In this paper, the ternary Li-ion battery is taken as the research object, and the Dual Polarization (DP) equivalent circuit model with temperature-varying parameters is established. The parameters of the Li-ion battery model at ambient temperature are identified by the forgetting factor least square method. Based on the state space equation of power battery SOC, an adaptive Sliding Mode Observer is used to study the estimation of the State of Charge of the power battery. The SOC estimation results are fully verified at low temperature (0 °C), normal temperature (25 °C), and high temperature (50 °C). The simulation results of the Urban Dynamometer Driving Schedule (UDDS) show that the SOC error estimated at low temperature and high temperature is within 2%, and the SOC error estimated at normal temperature is less than 1%, The algorithm has the advantages of accurate estimation, fast convergence, and strong robustness.

19.
Sensors (Basel) ; 22(2)2022 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-35062560

RESUMEN

With the advent of wearable communication devices, microstrip antennas have developed multiple applications due to their ultra-low-profile properties. Therefore, it is essential to analyze the problem of frequency shift and impedance mismatch when the antenna is bent. For the case of a rectangular patch antenna E-plane bent on the cylindrical surface, (1) this paper introduces the effective dielectric constant into the cavity model, which can accurately predict the resonance frequency of the antenna, and (2) according to the equivalent circuit model of the antenna resonance mode, the lumped element parameters are calculated based on the above effective dielectric constant, so that impedance characteristics and the S-parameter matching the port can be quickly constructed. From the perspective of circuit frequency characteristics, it explains the change in the transmission performance of the curved antenna. The experimental results show that the maximum difference between the experimental and theoretical calculation frequencies is less than 1%. These results verify the validity and applicability of the theory in the analysis of ultra-low-profile patch antennas and wearable electronic communication devices. It provides a theoretical basis for the fast impedance matching of patch antennas under different working conditions.

20.
Sensors (Basel) ; 22(7)2022 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-35408357

RESUMEN

The development of highly sensitive, portable and low-cost sensors for the evaluation of ethanol content in liquid is particularly important in several monitoring processes, from the food industry to the pharmaceutical industry. In this respect, we report the optimization of two sensing approaches based on electrical impedance spectroscopy (EIS) and complementary double split ring resonators (CDSRRs) for the detection of ethanol in water. Miniaturized EIS sensors were realized with interdigitated electrodes, and the ethanol sensing was carried out in liquid solutions without any functionalization of the electrodes. Impedance fitting analysis, with an equivalent circuit over a frequency range from 100 Hz to 1 MHz, was performed to estimate the electric parameters, which allowed us to evaluate the amount of ethanol in water solutions. On the other hand, complementary double split ring resonators (CDSRRs) were optimized by adjusting the device geometry to achieve higher quality factors while operating at a low fundamental frequency despite the small size (useful for compact electronic packaging). Both sensors were found to be efficient for the detection of low amounts of ethanol in water, even in the presence of salts. In particular, EIS sensors proved to be effective in performing a broadband evaluation of ethanol concentration and are convenient when low cost is the priority. On the other end, the employment of split ring resonators allowed us to achieve a very low limit of detection of 0.2 v/v%, and provides specific advantages in the case of known environments where they can enable fast real-time single-frequency measurements.


Asunto(s)
Espectroscopía Dieléctrica , Agua , Espectroscopía Dieléctrica/métodos , Impedancia Eléctrica , Electrodos , Etanol
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA