Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 584
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Stroke ; 55(4): 1086-1089, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38362812

RESUMEN

BACKGROUND: Spreading depolarization describes a near-complete electrical discharge with altered local cerebral blood flow. It is described in association with acute and chronic diseases like hemorrhagic stroke or migraine. Moyamoya vasculopathy is a chronic, progressive cerebrovascular disorder leading to cerebral hypoperfusion, hemodynamically insufficient basal collateralization, and increased cortical microvascularization. METHODS: In a prospective case series, we monitored for spontaneous spreading depolarization activity by using intraoperative laser speckle imaging for real-time visualization and measurement of cortical perfusion and cerebrovascular reserve capacity during cerebral revascularization in 4 consecutive patients with moyamoya. RESULTS: Spontaneous spreading depolarization occurrence was documented in a patient with moyamoya before bypass grafting. Interestingly, this patient also exhibited a marked preoperative increase in angiographic collateral vessel formation. CONCLUSIONS: The spontaneous occurrence of SDs in moyamoya vasculopathy could potentially provide an explanation for localized cortical infarction and increased cortical microvascular density in these patients.


Asunto(s)
Revascularización Cerebral , Trastornos Cerebrovasculares , Enfermedad de Moyamoya , Humanos , Enfermedad de Moyamoya/diagnóstico por imagen , Enfermedad de Moyamoya/cirugía , Angiografía Cerebral , Circulación Cerebrovascular/fisiología , Revascularización Cerebral/métodos , Enfermedad Crónica
2.
Microcirculation ; : e12880, 2024 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-39120967

RESUMEN

OBJECTIVE: Intragastric administration of ninjin'yoeito (NYT), a traditional Japanese herbal medicine, reportedly prevents the decrease in baseline cerebral blood flow (CBF) in the cortex following gastric administration of water. We investigated the effect of NYT on baseline and dynamic changes in cerebral cortical arteriole diameter. METHODS: Urethane-anesthetized mice were intragastrically administered 1 g/kg NYT or distilled water (DW). The artery in the left parietal cortex was imaged using two-photon microscopy. The baseline diameter of penetrating arterioles was measured before and 50-60 min after administration. Dynamic CBF and arteriole diameter changes before, during, and after transient occlusion of the left common carotid artery were measured approximately 10 min after administration. RESULTS: DW decreased the baseline diameter of the penetrating arterioles, whereas NYT did not. During occlusion, the increase in penetrating arteriole diameter was comparable for DW and NYT; however, during reperfusion, the return to preocclusion diameter was slower for NYT than DW. Laser-speckle contrast imaging confirmed that CBF, although comparable during occlusion, was higher during reperfusion for NYT than DW. CONCLUSIONS: These results suggest that NYT attenuates vasoconstriction in penetrating arterioles after intragastric administration and during cerebral reperfusion, contributing to CBF regulation.

3.
BMC Neurosci ; 25(1): 8, 2024 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-38350864

RESUMEN

Traumatic brain injury (TBI) is one of the leading causes of death and disability worldwide, and destruction of the cerebrovascular system is a major factor in the cascade of secondary injuries caused by TBI. Laser speckle imaging (LSCI)has high sensitivity in detecting cerebral blood flow. LSCI can visually show that transcranial focused ultrasound stimulation (tFUS) treatment stimulates angiogenesis and increases blood flow. To study the effect of tFUS on promoting angiogenesis in Controlled Cortical impact (CCI) model. tFUS was administered daily for 10 min and for 14 consecutive days after TBI. Cerebral blood flow was measured by LSCI at 1, 3, 7 and 14 days after trauma. Functional outcomes were assessed using LSCI and neurological severity score (NSS). After the last test, Nissl staining and vascular endothelial growth factor (VEGF) were used to assess neuropathology. TBI can cause the destruction of cerebrovascular system. Blood flow was significantly increased in TBI treated with tFUS. LSCI, behavioral and histological findings suggest that tFUS treatment can promote angiogenesis after TBI.


Asunto(s)
Lesiones Traumáticas del Encéfalo , Factor A de Crecimiento Endotelial Vascular , Ratones , Animales , Lesiones Traumáticas del Encéfalo/diagnóstico por imagen , Lesiones Traumáticas del Encéfalo/terapia , Lesiones Traumáticas del Encéfalo/patología , Circulación Cerebrovascular/fisiología
4.
Microvasc Res ; 152: 104640, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38065353

RESUMEN

The complexity of microvascular circulation has led to the development of advanced imaging techniques and biomimetic models. This study developed a multifaceted microfluidic-based microdevice as an in vitro model of microvasculature to replicate important geometric and functional features of in vivo perfusion in mice. The microfluidic device consisted of a microchannel for blood perfusion, mirroring the natural hierarchical branching vascular structures found in mice. Additionally, the device incorporated a steady gradient of oxygen (O2) which diffused through the polydimethylsiloxane (PDMS) layer, allowing for dynamic blood oxygenation. The assembled multi-layered microdevice was accompanied by a dual-modal imaging system that combined laser speckle contrast imaging (LSCI) and intrinsic signal optical imaging (ISOI) to visualize full-field blood flow distributions and blood O2 profiles. By closely reproducing in vivo blood perfusion and oxygenation conditions, this microvasculature model, in conjunction with numerical simulation results, can provide quantitative information on physiologically relevant hemodynamics and key O2 transport parameters that are not directly measurable in traditional animal studies.


Asunto(s)
Hemodinámica , Microfluídica , Ratones , Animales , Oxígeno , Microvasos
5.
Microvasc Res ; 152: 104654, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38215901

RESUMEN

BACKGROUND: Quantification of the vasodilation after topical application of capsaicin or cinnamaldehyde is often implemented to indirectly assess Transient Receptor Potential (TRP) Vanilloid 1 (TRPV1) or Ankyrin 1 (TRPA1) functionality respectively. This method has been well-established on the human forearm. However, to enable TRP functionality assessments in distal peripheral neuropathy, the vascular response upon TRP activation on dorsal finger skin was characterized. METHODS: Two doses of cinnamaldehyde (3 % and 10 % v/v) and capsaicin (300 µg and 1000 µg) were topically applied (20 µL) on the skin of the mid three proximal phalanges in 17 healthy men. The dose-response, and inter-hand and inter-period reproducibility of the dermal blood flow (DBF) increase was assessed using Laser Speckle Contrast Imaging (LSCI) during 60 min post-application. Linear mixed models explored dose-driven differences, whereas the intra-class correlation coefficient (ICC) estimated the reproducibility of the vascular response. RESULTS: Both doses of cinnamaldehyde and capsaicin induced a robust, dose-dependent increase in DBF. The vascular response to cinnamaldehyde 10 % on finger skin, expressed as area under the curve, correlated well over time (ICC = 0.66) and excellently between hands (ICC = 0.87). Similarly, the response to capsaicin 1000 µg correlated moderately over time (ICC = 0.50) and well between hands (ICC = 0.73). CONCLUSION: The vascular response upon topical cinnamaldehyde and capsaicin application on finger skin is an alternative approach for measurements on forearm skin. Thereby, it is a promising vascular read-out to investigate the pathophysiology, and TRP involvement in particular, of specific peripheral neuropathic pain syndromes.


Asunto(s)
Acroleína/análogos & derivados , Canales de Potencial de Receptor Transitorio , Masculino , Humanos , Capsaicina/farmacología , Reproducibilidad de los Resultados , Nervios Periféricos , Canales Catiónicos TRPV
6.
Surg Endosc ; 2024 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-39075313

RESUMEN

INTRODUCTION: Subjective surgeon interpretation of near-infrared perfusion video is limited by low inter-observer agreement and poor correlation to clinical outcomes. In contrast, quantification of indocyanine green fluorescence video (Q-ICG) correlates with histologic level of perfusion as well as clinical outcomes. Measuring dye volume over time, however, has limitations, such as it is not on-demand, has poor spatial resolution, and is not easily repeatable. Laser speckle contrast imaging quantification (Q-LSCI) is a real-time, dye-free alternative, but further validation is needed. We hypothesize that Q-LSCI will distinguish ischemic tissue and correlate over a range of perfusion levels equivalent to Q-ICG. METHODS: Nine sections of intestine in three swine were devascularized. Pairs of indocyanine green fluorescence imaging and laser speckle contrast imaging video were quantified within perfused, watershed, and ischemic regions. Q-ICG used normalized peak inflow slope. Q-LSCI methods were laser speckle perfusion units (LSPU), the base unit of laser speckle imaging, relative perfusion units (RPU), a previously described methodology which utilizes an internal control, and zero-lag normalized cross-correlation (X-Corr), to investigate if the signal deviations convey accurate perfusion information. We determine the ability to distinguish ischemic regions and correlation to Q-ICG over a perfusion gradient. RESULTS: All modalities distinguished ischemic from perfused regions of interest; Q-ICG values of 0.028 and 0.155 (p < 0.001); RPU values of 0.15 and 0.68 (p < 0.001); and X-corr values of 0.73 and 0.24 (p < 0.001). Over a range of perfusion levels, RPU had the best correlation with Q-ICG (r = 0.79, p < 0.001) compared with LSPU (r = 0.74, p < 0.001) and X-Corr (r = 0.46, p < 0.001). CONCLUSION: These results demonstrate that Q-LSCI discriminates ischemic from perfused tissue and represents similar perfusion information over a broad range of perfusion levels comparable to clinically validated Q-ICG. This suggests that Q-LSCI might offer clinically predictive real-time dye-free quantification of tissue perfusion. Further work should include validation in histologic studies and human clinical trials.

7.
Surg Endosc ; 2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39020119

RESUMEN

BACKGROUND: Anastomotic leakage (AL) is a dreaded complication following colorectal cancer surgery, impacting patient outcome and leads to increasing healthcare consumption as well as economic burden. Bowel perfusion is a significant modifiable factor for anastomotic healing and thus crucial for reducing AL. AIMS: The study aimed to calculate a cut-off value for quantified laser speckle perfusion units (LSPUs) in order to differentiate between ischemic and well-perfused tissue and to assess inter-observer reliability. METHODS: LSCI was performed using a porcine ischemic small bowel loop model with the PerfusiX-Imaging® system. An ischemic area, a well-perfused area, and watershed areas, were selected based on the LSCI colormap. Subsequently, local capillary lactate (LCL) levels were measured. A logarithmic curve estimation tested the correlation between LSPU and LCL levels. A cut-off value for LSPU and lactate was calculated, based on anatomically ischemic and well-perfused tissue. Inter-observer variability analysis was performed with 10 observers. RESULTS: Directly after ligation of the mesenteric arteries, differences in LSPU values between ischemic and well-perfused tissue were significant (p < 0.001) and increased significantly throughout all following measurements. LCL levels were significantly different (p < 0.001) at both 60 and 120 min. Logarithmic curve estimation showed an R2 value of 0.56 between LSPU and LCL values. A LSPU cut-off value was determined at 69, with a sensitivity of 0.94 and specificity of 0.87. A LCL cut-off value of 3.8 mmol/L was found, with a sensitivity and specificity of 0.97 and 1.0, respectively. There was no difference in assessment between experienced and unexperienced observers. Cohen's Kappa values were moderate to good (0.52-0.66). CONCLUSION: Real-time quantification of LSPUs may be a feasible intraoperative method to assess tissue perfusion and a cut-off value could be determined with high sensitivity and specificity. Inter-observer variability was moderate to good, irrespective of prior experience with the technique.

8.
Artif Organs ; 48(4): 347-355, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37962102

RESUMEN

BACKGROUND: Validated quantitative biomarkers for assessment of renal graft function during normothermic machine perfusion (NMP) conditions are lacking. The aim of this project was to quantify cortex microperfusion during ex vivo kidney perfusion using laser speckle contrast imaging (LSCI), and to evaluate the sensitivity of LSCI when measuring different levels of renal perfusion. Furthermore, we aimed to introduce LSCI measurements during NMP in differentially damaged kidneys. METHODS: Eleven porcine kidneys were nephrectomized and perfused ex vivo. Cortex microperfusion was simultaneously monitored using LSCI. First, a flow experiment examined the relationship between changes in delivered renal flow and corresponding changes in LSCI-derived cortex microperfusion. Second, renal cortical perfusion was reduced stepwise by introducing a microembolization model. Finally, LSCI was applied for measuring renal cortex microperfusion in kidneys exposed to minimal damage or 2 h warm ischemia (WI). RESULTS: Cortex microperfusion was calculated from the LSCI-obtained data. The flow experiment resulted in relatively minor changes in cortex microperfusion compared to the pump-induced changes in total renal flow. Based on stepwise injections of microspheres, we observed different levels of cortex microperfusion that correlated with administrated microsphere dosages (r2 = 0.95-0.99). We found no difference in LSCI measured cortex microperfusion between the kidneys exposed to minimal damage (renal cortex blood flow index, rcBFI = 2090-2600) and 2 h WI (rcBFI = 2189-2540). CONCLUSIONS: Based on this preliminary study, we demonstrated the feasibility of LSCI in quantifying cortex microperfusion during ex vivo perfusion. Furthermore, based on LSCI-measurements, cortical microperfusion was similar in kidneys exposed to minimal and 2 h WI.


Asunto(s)
Trasplante de Riñón , Imágenes de Contraste de Punto Láser , Animales , Porcinos , Velocidad del Flujo Sanguíneo , Riñón/irrigación sanguínea , Circulación Renal
9.
Langenbecks Arch Surg ; 409(1): 147, 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38695955

RESUMEN

PURPOSE: To investigate the accuracy of laser speckle flowgraphy (LSFG), a noninvasive method for the quantitative evaluation of blood flow using mean blur rate (MBR) as a blood flow parameter in the assessment of bowel blood perfusion compared to indocyanine green fluorescence angiography (ICG-FA). METHODS: We enrolled 46 patients who underwent left-sided colorectal surgery. LSFG and ICG-FA were applied to assess blood bowel perfusion, with MBR and luminance as parameters, respectively. In both measurement methods, the position where the parameter suddenly decreased was defined as the blood flow boundary line. Subsequently, the blood flow boundaries created after processing the blood vessels flowing into the intestinal tract were determined using LSFG and ICG-FA, and concordance between the two was examined. Blood flow boundaries were visually identified using color tone changes on a color map created based on MBR in LSFG and using differences in luminance in ICG-FA. The distances between the transection line and blood flow boundaries determined using each method were compared. RESULTS: The location of blood flow boundaries matched in 65% (30/46) of cases. Although locations differed in the remaining 35% (16/46), all were located on the anal side near the transection line, and the difference was not clinically significant. The average distances between the transection line and blood flow boundary were 2.76 (SD = 3.25) and 3.71 (SD = 4.26) mm, respectively. There was no statistically significant difference between the two groups (p = 0.38). CONCLUSION: LSFG was shown to have comparable accuracy to ICG-FA, and may be useful for evaluating bowel perfusion.


Asunto(s)
Colorantes , Angiografía con Fluoresceína , Verde de Indocianina , Humanos , Femenino , Angiografía con Fluoresceína/métodos , Masculino , Anciano , Persona de Mediana Edad , Imágenes de Contraste de Punto Láser , Anciano de 80 o más Años , Flujo Sanguíneo Regional/fisiología , Adulto , Intestinos/irrigación sanguínea , Velocidad del Flujo Sanguíneo/fisiología , Neoplasias Colorrectales/cirugía
10.
Lasers Surg Med ; 56(6): 564-573, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38890796

RESUMEN

OBJECTIVES: Under optimal conditions, afferent and efferent human skin graft microcirculation can be restored 8-12 days postgrafting. Still, the evidence about the reperfusion dynamics beyond this period in a dermato-oncologic setting is scant. We aimed to characterise the reperfusion of human skin grafts over 4 weeks according to the necrosis extension (less than 20%, or 20%-50%) and anatomic location using laser speckle contrast imaging (LSCI). METHODS: Over 16 months, all eligible adults undergoing skin grafts following skin cancer removal on the scalp, face and lower limb were enroled. Perfusion was assessed with LSCI on the wound margin (control skin) on day 0 and on the graft surface on days 7, 14, 21 and 28. Graft necrosis extension was determined on day 28. RESULTS: Forty-seven grafts of 47 participants were analysed. Regardless of necrosis extension, graft perfusion equalled the control skin by day 7, surpassed it by day 21, and stabilised onwards. Grafts with less than 20% necrosis on the scalp and lower limb shared this reperfusion pattern and had a consistently better-perfused centre than the periphery for the first 21 days. On the face, the graft perfusion did not differ from the control skin from day 7 onwards, and there were no differences in reperfusion within the graft during the study. CONCLUSION: Skin graft reperfusion is a protracted process that evolves differently in the graft centre and periphery, influenced by postoperative time and anatomic location. A better knowledge of this process can potentially enhance the development of strategies to induce vessel ingrowth into tissue-engineered skin substitutes.


Asunto(s)
Imágenes de Contraste de Punto Láser , Reperfusión , Trasplante de Piel , Humanos , Masculino , Femenino , Trasplante de Piel/métodos , Persona de Mediana Edad , Anciano , Reperfusión/métodos , Neoplasias Cutáneas/cirugía , Neoplasias Cutáneas/patología , Necrosis , Cuero Cabelludo/irrigación sanguínea , Factores de Tiempo , Adulto , Anciano de 80 o más Años , Piel/irrigación sanguínea , Piel/diagnóstico por imagen , Piel/patología , Microcirculación , Estudios Prospectivos , Periodo Posoperatorio
11.
Ophthalmic Res ; 67(1): 257-265, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38508153

RESUMEN

INTRODUCTION: Microcirculation of optic nerve head (ONH) in open-angle glaucoma (OAG) patients with unilateral visual field (VF) loss has yet to be fully investigated, especially the perimetrically unaffected fellow eyes. METHODS: Thirty-eight OAG patients with VF defect in one eye and normal VF in the other eye, and thirty-one healthy participants were analyzed. All participants underwent laser speckle flowgraphy (LSFG), spectral-domain optical coherence tomography (SD-OCT) imaging, and VF test for further analyses. LSFG measurements included mean blur rate in all area of ONH (MA), big vessel area of ONH (MV), and tissue area of ONH (MT). SD-OCT parameters included circumpapillary retinal nerve fiber layer (cpRNFL) thickness and macula thicknesses. The difference of LSFG and SD-OCT indices between glaucoma patients and healthy controls were compared. The diagnostic accuracy was analyzed with the areas under the receiver operating characteristic curves (AROCs). RESULTS: Global cpRNFL thickness and macular thickness in unaffected eyes of OAG patients were higher than their fellow eyes and lower than healthy eyes. MA and MV in healthy eyes and unaffected eyes were significantly higher than in affected eyes. MT in unaffected eyes of OAG patients was higher than in their fellow affected eyes but lower than in healthy eyes. The AROCs were highest for cpRNFL (0.925), followed by macular thickness (0.838), and MT (0.834). CONCLUSIONS: ONH microcirculation in perimetrically unaffected fellow eyes was decreased in OAG patients with unilateral VF loss. LSFG can detect changes of ONH in high-risk eyes before detectable VF damage, which may reflect the vascular pathophysiology for glaucoma.


Asunto(s)
Glaucoma de Ángulo Abierto , Microcirculación , Fibras Nerviosas , Disco Óptico , Células Ganglionares de la Retina , Tomografía de Coherencia Óptica , Campos Visuales , Humanos , Glaucoma de Ángulo Abierto/fisiopatología , Glaucoma de Ángulo Abierto/diagnóstico , Masculino , Femenino , Disco Óptico/irrigación sanguínea , Microcirculación/fisiología , Campos Visuales/fisiología , Tomografía de Coherencia Óptica/métodos , Persona de Mediana Edad , Fibras Nerviosas/patología , Células Ganglionares de la Retina/patología , Anciano , Presión Intraocular/fisiología , Pruebas del Campo Visual , Flujometría por Láser-Doppler , Curva ROC , Vasos Retinianos/fisiopatología , Vasos Retinianos/diagnóstico por imagen
12.
Acta Neurochir (Wien) ; 166(1): 27, 2024 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-38261093

RESUMEN

Adenosine induced cardiac arrest (AiCA) is one of the methods used to facilitate microsurgical aneurysm clipping by providing more visibility and less pressure in the aneurysmal sac and neighboring vessels. We report the use of laser speckle contrast imaging (LSCI) during AiCA to monitor the changes in pulsation and perfusion on the cortical surface during adenosine induced cardiac arrest for aneurysm clipping surgery. Application of this technology for perfusion monitoring may improve workflow and surgical guidance and provide valuable feedback continuously throughout the procedure. ClinicalTrials.gov identifier: NCT0502840.


Asunto(s)
Aneurisma , Imágenes de Contraste de Punto Láser , Humanos , Perfusión , Adenosina , Paro Cardíaco Inducido
13.
Neurocrit Care ; 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38982003

RESUMEN

BACKGROUND: Dynamic monitoring of the blood-brain barrier (BBB) functional status in septic mice can help to explore the pathological mechanisms. Therefore, we proposed a new method for monitoring BBB permeability and applied it to the detection of sepsis models. METHODS: The new method involves the construction of an optical cranial window and in vivo imaging. We performed dynamic monitoring of BBB permeability and cerebral blood flow (CBF) in cecal ligation puncture (CLP) and endotoxemia (lipopolysaccharide [LPS]) mice. RESULTS: The sensitivity and accuracy of this method were higher than those of Evans blue evaluation. The increase of BBB permeability in the group of CLP mice was relatively mild and correlated with overall survival, and the damage was irreversible. Contrarily, BBB damage in the LPS group was more acute and severe, unrelated to overall survival, but recoverable. The CBF decreased significantly in both model mouse groups 24 h after modeling, but only the CBF proportion decrease in the LPS group was significantly correlated with an increase in BBB permeability. Within 24 h after both models were established, the decrease in blood flow in the digestive organs occurred earlier than in the brain and kidneys, and the decrease in small intestine blood flow in the LPS group progressed faster. CONCLUSIONS: We have successfully demonstrated the feasibility of our novel method to detect BBB permeability in mice. Our results revealed a significant difference in the BBB permeability change trend between the CLP and LPS model mice when survival curves were consistent. Notably, the CLP-model mice demonstrated a closer resemblance to clinical patients. Our findings suggest that early-stage brain tissue hypoperfusion has a greater impact on BBB function damage in endotoxemia mice, which is related to the faster progression of blood flow redistribution.

14.
Aesthetic Plast Surg ; 48(6): 1067-1075, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37816946

RESUMEN

BACKGROUND: Although laser Doppler imaging (LDI) accurately delineates a hypoperfused area to help target hyaluronidase treatment, laser speckle contrast imaging (LSCI) is more appropriate for assessing microvascular hemodynamics and has greater reproducibility than LDI. This study investigated the use of LSCI in the evaluation and treatment of six patients who developed vascular complications after facial dermal filler injections. METHODS: The areas of vascular occlusion were accurately defined in real time by LSCI and were more precise than visual inspections or photographic evidence for guiding needling and hyaluronidase treatment. RESULTS: All patients had achieved satisfactory outcomes as early as Day 2 of treatment and no procedure-related complications were reported after a median follow-up of 9.5 (7-37) days. CONCLUSION: LSCI accurately and noninvasively delineated vascular occlusions in real time among patients experiencing complications of facial dermal filler injections. Moreover, LSCI was more accurate than visual and photographic evaluations. Clinicians can use LSCI to reliably follow-up therapeutic outcomes after salvage interventions for vascular occlusions. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Asunto(s)
Técnicas Cosméticas , Rellenos Dérmicos , Humanos , Rellenos Dérmicos/efectos adversos , Imágenes de Contraste de Punto Láser , Hialuronoglucosaminidasa , Reproducibilidad de los Resultados , Inducción Percutánea del Colágeno , Técnicas Cosméticas/efectos adversos , Ácido Hialurónico
15.
Aesthetic Plast Surg ; 2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38862659

RESUMEN

BACKGROUND: Nipple-areola complex (NAC) necrosis is a major complication for breast reconstruction after nipple-sparing mastectomy. Although intraoperative indocyanine green angiography helps to assess the viability of tissue, the imaging could be conservative which may lead to aggressive resection. The plastic surgeons are eager to know the perfusion changes of NAC throughout the perioperative period. METHODS: In this prospective cohort study, the authors enrolled patients who underwent NSM and immediate direct-to-implant breast reconstruction. All patients underwent laser speckle contrast imaging before surgery, immediately after mastectomy, after implant placement, and 24 h and 72 h after surgery. RESULTS: A total of 94 breasts were analyzed, including 64 breasts healed with viable NAC and 30 breasts with NAC necrosis. In viable NACs, the average blood supply decreased to 56% after NSM and 42% after reconstruction, then recovered to 68% and 80% at 24-h and 72-h post-operation. In necrotic NACs, the average blood supply decreased to 33% after NSM and 24% after reconstruction, and partial perfusion recovery was also recorded at 24-h (31%) and 72-h (37%) post-operation. The cutoff value for predicting NAC viability is 40% after NSM and 25% after implant placement. CONCLUSIONS: The study quantified the NAC perfusion changes during the perioperative period. NAC perfusion decreased significantly after NSM and would be the lowest after the end of breast reconstruction. Viable NACs displayed more perfusion during the operation and showed significant nipple revascularization after breast reconstruction. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

16.
Orbit ; 43(4): 464-470, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38687914

RESUMEN

PURPOSE: In oculoplastic surgery the eyelid tissue is frequently stretched in order to repair defects after tumor surgery. However, there is a paucity of research regarding how stretching affects eyelids. The purpose of this study was to gain insight into how traction force affects eyelid stretch as well as tissue perfusion, using a laser-based in vivo monitoring technique. METHOD: Lower-lid pentagonal resections were performed in eight patients and a total of nine eyelids. The medial section of the eyelid was then stretched using a dynamometer up to a force of 2.3 Newtons (N), and eyelid stretching and blood perfusion were continuously measured using laser speckle contrast imaging. RESULTS: Tissue perfusion decreased exponentially when eyelid tissue was stretched, with an initial sharp decline followed by a more gradual reduction. Perfusion approached zero at a force of approximately 2.0 N. The length of the eyelid increased with increasing force up to 1.5 N, after which there was only a very slight increase in length. CONCLUSIONS: Eyelid tissue seems to respond to traction in a non-linear fashion, where the initial force results in the greatest eyelid stretching and reduction in blood perfusion. The results provide information on the effects of a large force for direct closure of large eyelid defects. Considering how quickly perfusion approaches zero, the high success rate of eyelid reconstruction surgery is likely a testament to the extensive vascularization of the periocular region.


Asunto(s)
Párpados , Flujo Sanguíneo Regional , Humanos , Párpados/cirugía , Párpados/irrigación sanguínea , Femenino , Masculino , Anciano , Flujo Sanguíneo Regional/fisiología , Persona de Mediana Edad , Tracción , Imágenes de Contraste de Punto Láser , Neoplasias de los Párpados/cirugía , Neoplasias de los Párpados/fisiopatología , Anciano de 80 o más Años , Procedimientos de Cirugía Plástica/métodos , Blefaroplastia/métodos
17.
Orbit ; 43(4): 453-463, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38591750

RESUMEN

PURPOSE: The gold standard for skin cancer diagnosis is surgical excisional biopsy and histopathological examination. Several non-invasive diagnostic techniques exist, although they have not yet translated into clinical use. This is a proof-of-concept study to assess the possibility of imaging an angiosarcoma in the periocular area. METHODS: We use laser speckle, hyperspectral, and photoacoustic imaging to monitor blood perfusion and oxygen saturation, as well as the molecular composition of the tissue. The information obtained from each imaging modality was combined in order to yield a more comprehensive picture of the function, as well as molecular composition of a rapidly growing cutaneous angiosarcoma in the periocular area. RESULTS: We found an increase in perfusion coupled with a reduction in oxygen saturation in the angiosarcoma. We could also extract the molecular composition of the angiosarcoma at a depth, depicting both the oxygen saturation and highlighting the presence of connective tissue via collagen. CONCLUSIONS: We demonstrate the different physiological parameters that can be obtained with the different techniques and how these can be combined to provide detailed 3D maps of the functional and molecular properties of tumors useful in preoperative assessment.


Asunto(s)
Hemangiosarcoma , Imagenología Tridimensional , Técnicas Fotoacústicas , Humanos , Hemangiosarcoma/diagnóstico por imagen , Hemangiosarcoma/patología , Neoplasias Cutáneas/diagnóstico por imagen , Neoplasias Cutáneas/patología , Imágenes Hiperespectrales , Oxígeno/sangre , Masculino , Femenino , Rayos Láser , Prueba de Estudio Conceptual
18.
Int Ophthalmol ; 44(1): 181, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38625618

RESUMEN

PURPOSE: To assess ocular blood flow (OBF) changes in patients with neovascular age-related macular degeneration (nAMD) treated with intravitreal injections of ranibizumab biosimilar (IVRbs) or brolucizumab (IVBr). METHODS: This retrospective longitudinal study included 43 eyes of 43 patients (74.5 ± 9.8 years old, male to female ratio 31:12) with nAMD treated with IVBr (29 eyes) or IVRbs (14 eyes). OBF in the optic nerve head (ONH) and choroid (Ch) was measured with laser speckle flowgraphy (Softcare Co., Ltd., Fukutsu, Japan) before and one month after treatment. Changes in mean blur rate (MBR) before and after each treatment were tested using Wilcoxon's signed-rank tests and mixed-effect models for repeated measures. RESULTS: In the IVBr group, MBR was significantly reduced in both the ONH and Ch (p < 0.01). In contrast, the IVRbs group showed no significant change in MBR in either the ONH or Ch (p = 0.56, p = 1). The linear mixed effect model showed a significant interaction between time and anti-VEGF drugs for MBR in both the ONH and Ch (ONH: p = 0.04; Ch: p = 0.002). A post hoc pairwise comparison of estimated marginal means showed that MBR decreased significantly only after IVBr (p < 0.001). CONCLUSION: Our findings suggest that the short-term impact on OBF varies depending on the drug used for nAMD.


Asunto(s)
Anticuerpos Monoclonales Humanizados , Biosimilares Farmacéuticos , Degeneración Macular , Disco Óptico , Humanos , Femenino , Masculino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Ranibizumab , Inyecciones Intravítreas , Estudios Longitudinales , Estudios Retrospectivos , Degeneración Macular/diagnóstico , Degeneración Macular/tratamiento farmacológico
19.
Microcirculation ; 30(1): e12795, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36524297

RESUMEN

OBJECTIVE: Laser-based tissue perfusion monitoring techniques have been increasingly used in animal and human research to assess blood flow. However, these techniques use arbitrary units, and knowledge about their comparability is scarce. This study aimed to model the relationship between laser speckle contrast imaging (LSCI) and laser Doppler perfusion imaging (LDPI), for measuring tissue perfusion over a wide range of blood flux values. METHODS: Fifteen healthy volunteers (53% female, median age 29 [IQR 22-40] years) were enrolled in this study. We performed iontophoresis with sodium nitroprusside on the forearm to induce regional vasodilation to increase skin blood flux. Besides, a stepwise vascular occlusion was applied on the contralateral upper arm to reduce blood flux. Both techniques were compared using a linear mixed model analysis. RESULTS: Baseline blood flux values measured by LSCI were 33 ± 6.5 arbitrary unit (AU) (Coefficient of variation [CV] = 20%) and by LDPI 60 ± 11.5 AU (CV = 19%). At the end of the iontophoresis protocol, the regional blood flux increased to 724 ± 412% and 259 ± 87% of baseline measured by LDPI and LSCI, respectively. On the other hand, during the stepwise vascular occlusion test, the blood flux reduced to 212 ± 40% and 412 ± 177% of its baseline at LDPI and LSCI, respectively. A strong correlation was found between the LSCI and LDPI instruments at increased blood flux with respect to baseline skin blood flux; however, the correlation was weak at reduced blood flux with respect to baseline. DISCUSSION: LSCI and LDPI instruments are highly linear for blood flux higher than baseline skin blood flux; however, the correlation decreased for blood flux lower than baseline. This study's findings could be a basis for using LSCI in specific patient populations, such as burn care.


Asunto(s)
Imágenes de Contraste de Punto Láser , Imagen de Perfusión , Animales , Humanos , Femenino , Adulto , Masculino , Velocidad del Flujo Sanguíneo , Perfusión , Microcirculación , Imagen de Perfusión/métodos , Rayos Láser , Flujo Sanguíneo Regional , Flujometría por Láser-Doppler/métodos , Piel/irrigación sanguínea
20.
Microvasc Res ; 148: 104509, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36822366

RESUMEN

OBJECTIVE: To evaluate finger proximal-distal gradient (PDG) perfusion in subjects with primary Raynaud's phenomenon (PRP), then making comparisons with systemic sclerosis (SSc) patients and healthy controls (HC). METHODS: Consecutive adult PRP subjects were enrolled, along with an equal number of SSc and HC. Peripheral blood perfusion of the hands was assessed by laser speckle contrast analysis (LASCA). PDG was then calculated applying a generalizable formula independent of both intra- and inter-personal factors. Non-specific anti-nuclear autoantibody (ANA) isolated positivity was assessed. RESULTS: Fifty PRP patients (88 % female, mean age 45 ± 17.9 years) were enrolled, along with 50 SSc patients and 50 HC. After adjusting mean PDG results for age and sex, no significant differences emerged between PRP and SSc (1.80 ± 0.43 vs 1.76 ± 0.53; p = 0.294). Conversely, PRP values were significantly reduced when compared to HC (2.72 ± 0.37; p < 0.001). Among PRP subjects, no significant differences were found regarding isolated ANA positivity (1.86 ± 0.44 vs 1.74 ± 0.44; p = 0.42). CONCLUSION: PRP and SSc seems to share the same basal PDG perfusion impairment assessed by LASCA. Isolated ANA positivity, in the absence of clinical and capillaroscopic suspicion for secondary causes, should not be considered an exclusion criterion for PRP classification.


Asunto(s)
Enfermedad de Raynaud , Esclerodermia Sistémica , Adulto , Humanos , Femenino , Persona de Mediana Edad , Masculino , Piel , Flujo Sanguíneo Regional , Esclerodermia Sistémica/diagnóstico , Perfusión , Enfermedad de Raynaud/diagnóstico , Rayos Láser
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA