1.
Artículo en Inglés | MEDLINE | ID: mdl-38923693

RESUMEN

INTRODUCTION: Pacemaker-mediated tachycardia is a known arrhythmia in patients with dual chamber pacemakers and defibrillators and intact ventriculoatrial (VA) conduction. We report a case of pacemaker-mediated reentrant arrhythmia (PMRA) in a patient with an atrioventricular (AV) synchronous leadless pacemaker. METHODS AND RESULTS: A 91-year-old female presented with 2:1 AV conduction and received an AV synchronous leadless pacemaker. She had atrial mechanical sense-ventricular paced beats between heart rates of 80-100 bpm more than 80% of the time. She was found to have a new cardiomyopathy and was referred for placement of biventricular pacemaker. At the time of device implantation, her electrocardiogram showed ventricular pacing with a short RP interval and superiorly directed P waves. Changes in the ventricular pacing rate resulted in changes in the atrial rate. Following device placement, her heart rate decreased to the lower rate limit of her pacemaker. The atrial mechanical sense impulse most likely was generated by a retrograde conducted P wave resulting in near incessant PMRA. CONCLUSION: PMRA may occur in patients who receive an AV synchronous leadless pacemaker with intact VA conduction and sinoatrial node dysfunction. Due to the lower rates of PMRA, this arrhythmia may be underrecognized. Interventions for and implications of PMRA need further investigation.

2.
Artículo en Inglés | MEDLINE | ID: mdl-39135352

RESUMEN

INTRODUCTION: Severe obesity presents significant challenges in imaging and delivery of therapy, including pacemaker implant. METHODS AND RESULT: We present our experience implanting a leadless pacemaker (LP) in a severely obese man presenting with heart block. We describe our multidisciplinary approach using right internal jugular venous access and transesophageal imaging in lieu of fluoroscopy which failed to provide workable images in this instance. CONCLUSION: Ultrasound guided LP placement may have wider application in the midst of an ongoing obesity epidemic where fluoroscopy imaging is both limited and unsafe.

3.
J Cardiovasc Electrophysiol ; 35(6): 1232-1234, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38534004

RESUMEN

INTRODUCTION: Pacemaker implantation can be challenging in patients with congenital heart disease. METHODS AND RESULTS: In a patient with Ebstein disease and symptomatic sinus node dysfunction, despite multiple attempts, the Micra® pacemaker could not be implanted in the severely dilated right ventricle. In that context, and after iodine injection to confirm the appropriate location, the Micra® pacemaker was successfully implanted in the right appendage at the first attempt. CONCLUSION: Despite the recent development of dedicated dual-chamber leadless pacemaker, to the best of our knowledge, this case is the first off-label Micra® implantation in a right appendage.


Asunto(s)
Apéndice Atrial , Estimulación Cardíaca Artificial , Marcapaso Artificial , Humanos , Apéndice Atrial/fisiopatología , Apéndice Atrial/cirugía , Apéndice Atrial/diagnóstico por imagen , Síndrome del Seno Enfermo/terapia , Síndrome del Seno Enfermo/fisiopatología , Síndrome del Seno Enfermo/diagnóstico , Anomalía de Ebstein/cirugía , Anomalía de Ebstein/fisiopatología , Resultado del Tratamiento , Masculino , Diseño de Equipo
4.
J Cardiovasc Electrophysiol ; 35(7): 1351-1359, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38695242

RESUMEN

INTRODUCTION: Leadless pacemakers (LPM) have established themselves as the important therapeutic modality in management of selected patients with symptomatic bradycardia. To determine real-world utilization and in-hospital outcomes of LPM implantation since its approval by the Food and Drug Administration in 2016. METHODS: For this retrospective cohort study, data were extracted from the National Inpatient Sample database from the years 2016-2020. The outcomes analyzed in our study included implantation trends of LPM over study years, mortality, major complications (defined as pericardial effusion requiring intervention, any vascular complication, or acute kidney injury), length of stay, and cost of hospitalization. Implantation trends of LPM were assessed using linear regression. Using years 2016-2017 as a reference, adjusted outcomes of mortality, major complications, prolonged length of stay (defined as >6 days), and increased hospitalization cost (defined as median cost >34 098$) were analyzed for subsequent years using a multivariable logistic regression model. RESULTS: There was a gradual increased trend of LPM implantation over our study years (3230 devices in years 2016-2017 to 11 815 devices in year 2020, p for trend <.01). The adjusted mortality improved significantly after LPM implantation in subsequent years compared to the reference years 2016-2017 (aOR for the year 2018: 0.61, 95% CI: 0.51-0.73; aOR for the year 2019: 0.49, 95% CI: 0.41-0.59; and aOR for the year 2020: 0.52, 95% CI: 0.44-0.62). No differences in adjusted rates of major complications were demonstrated over the subsequent years. The adjusted cost of hospitalization was higher for the years 2019 (aOR: 1.33, 95% CI: 1.22-1.46) and 2020 (aOR: 1.69, 95% CI: 1.55-1.84). CONCLUSION: The contemporary US practice has shown significantly increased implantation rates of LPM since its approval with reduced rates of inpatient mortality.


Asunto(s)
Estimulación Cardíaca Artificial , Bases de Datos Factuales , Costos de Hospital , Tiempo de Internación , Marcapaso Artificial , Humanos , Marcapaso Artificial/tendencias , Marcapaso Artificial/economía , Estados Unidos , Estudios Retrospectivos , Masculino , Femenino , Anciano , Resultado del Tratamiento , Costos de Hospital/tendencias , Factores de Tiempo , Persona de Mediana Edad , Estimulación Cardíaca Artificial/tendencias , Estimulación Cardíaca Artificial/economía , Estimulación Cardíaca Artificial/mortalidad , Estimulación Cardíaca Artificial/efectos adversos , Tiempo de Internación/tendencias , Factores de Riesgo , Anciano de 80 o más Años , Bradicardia/terapia , Bradicardia/mortalidad , Bradicardia/diagnóstico , Frecuencia Cardíaca , Mortalidad Hospitalaria/tendencias , Diseño de Equipo/tendencias
5.
J Cardiovasc Electrophysiol ; 35(8): 1706-1709, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38894506

RESUMEN

INTRODUCTION: Leadless pacemakers are associated with a low risk of infection, so indications for their removal are rare. One can expect that the dwell time of the device correlates with a more difficult removal, but it has not been proved so far. METHODS AND RESULTS: We present a case of a patient in whom MICRA transcatheter pacing system was successfully removed with nondedicated commercially available tools, 70 months after implantation. CONCLUSION: A successful removal of the MICRA leadless pacemaker is possible, and may be safe even many years after the device implantation, despite a lack of dedicated tools. Due to the potential risk of complications, the benefits and risks of the procedure should be weighted before making a final decision.


Asunto(s)
Remoción de Dispositivos , Diseño de Equipo , Marcapaso Artificial , Humanos , Estimulación Cardíaca Artificial , Resultado del Tratamiento , Masculino , Femenino , Factores de Tiempo , Anciano de 80 o más Años , Anciano
6.
J Cardiovasc Electrophysiol ; 35(6): 1115-1120, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38534012

RESUMEN

INTRODUCTION: Few studies have demonstrated a high degree of atrioventricular (AV) synchrony with a new leadless pacemaker called Micra AV. Our group previously reported a new and unique sensing method. We believe that this novel sensing method, "Simplified A3 method," might facilitate better AV synchrony than a conventional sensing method in almost all cases with Micra AV implantation. METHODS: We conducted a non-randomized retrospective study comparing the two pacing methods at two centers. From December 1, 2021 to October 31, 2022, Micra AV was implanted for 32 patients at the two centers. Twenty of the 32 patients with sinus rhythm and complete AV block were included in this study. In Group 1, the conventional setting was programmed as follows: auto A3 threshold, auto A3 window-end (WE), and auto A4 threshold turned on during hospitalization. In Group 2, the "Simplified A3 method" was programmed as follows: auto A3 threshold and auto A3WE turned off. Instead, an intentionally prolonged A3WE (850-1000 ms) and low A3 threshold (A3 signal amplitude + 0.5-1.0 m/s2) were programmed. RESULTS: Twenty patients were analyzed. In Group 2, AV synchrony (%AMVp) was significantly higher at the first outpatient clinic (63.0 ± 5.7% vs 81.0 ± 4.2%, p = .03). A3 threshold was significantly lower in Group 2 (5.9 ± 0.7 m/s2, p < .05 vs 2.3 ± 0.5 m/s2, p < .05). CONCLUSION: Our novel sensing method might be a more feasible sensing method for obtaining higher AV synchrony than the conventional algorithm.


Asunto(s)
Potenciales de Acción , Bloqueo Atrioventricular , Estimulación Cardíaca Artificial , Estudios de Factibilidad , Frecuencia Cardíaca , Marcapaso Artificial , Humanos , Masculino , Femenino , Estimulación Cardíaca Artificial/métodos , Estudios Retrospectivos , Anciano , Bloqueo Atrioventricular/terapia , Bloqueo Atrioventricular/fisiopatología , Bloqueo Atrioventricular/diagnóstico , Resultado del Tratamiento , Diseño de Equipo , Anciano de 80 o más Años , Persona de Mediana Edad , Factores de Tiempo , Valor Predictivo de las Pruebas , Nodo Atrioventricular/fisiopatología , Procesamiento de Señales Asistido por Computador
7.
Europace ; 26(3)2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38449430

RESUMEN

The second generation of transcatheter pacing systems, called Micra AV, can provide atrioventricular (AV) synchronous pacing via a new pacing algorithm relying on sensing mechanical atrial contraction. Several novel programming parameters were introduced to enable AV synchronous pacing, including an A3 window and A4 window as well as a conduction mode switch and an activity mode switch. In addition to several automated features, manual programming optimization of some of the novel parameters is key to improving AV synchrony. A solid knowledge of the features and their programming is essential for electrophysiologists implanting or following patients with Micra AV devices. Differences in programming optimization might partially explain the high variability of AV synchrony published in real-world data reports. This article reviews the key programming parameters of Micra AV. Subsequently, optimal programming recommendations for defined patient profiles are presented. Those were established by consensus within an expert panel comprised of 11 European electrophysiologists from high-volume Micra AV centres. The patient profiles were (1) high degree AV block and slow sinus rhythm; (2) high degree AV block and fast sinus rhythm; and (3) intermittent AV block. The panel recommended to evaluate the mechanical atrial activity on transthoracic echocardiography prior to implant. It was also agreed that Auto A3 Threshold and Tracking Check should be turned off in all patients, AV conduction mode switch should be turned off in all patients with high degree AV block, and the lower rate should be programmed to 50 bpm with exceptions based on individual clinical assessment. Future studies will be useful to evaluate the strength of those recommendations to improve the AV synchrony.


Asunto(s)
Bloqueo Atrioventricular , Marcapaso Artificial , Humanos , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/terapia , Estimulación Cardíaca Artificial/efectos adversos , Arritmias Cardíacas/terapia , Frecuencia Cardíaca/fisiología
8.
Europace ; 26(3)2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38457487

RESUMEN

AIMS: Aveir VR performance and predictors for its pacing threshold (PCT) in a real-world cohort were investigated. METHODS: Electrical measurements at various stages of an Aveir VR implant were prospectively collected. Predictors for 3-month PCT were studied. A retrospective cohort of consecutive 139 Micra implants was used to compare the PCT evolution. High PCT was defined as ≥1.5 V, using a pulse width of 0.4 ms for Aveir and 0.24 ms for Micra. Excellent PCT was defined as ≤0.5 V at the respective pulse width. RESULTS: Among the 123 consecutive Aveir VR implant attempts, 122 (99.2%) were successful. The majority were of advanced age (mean 79.7) and small body size (mean BSA 1.60). Two patients (1.6%) experienced complications, including one pericardial effusion after device reposition and one intraoperative device dislodgement. Eighty-eight patients reached a 3-month follow-up. Aveir 3-month PCT was correlated with impedance at mapping (P = 0.015), tether mode (P < 0.001), end-of-procedure (P < 0.001), and mapping PCT (P = 0.035), but not with PCTs after fixation (P > 0.05). Tether mode impedance >470 ohms had 88% sensitivity and 71% specificity in predicting excellent 3-month PCT. Although it is more common for Aveir to have high PCT at end of procedure (11.5% for Aveir and 2.2% for Micra, P = 0.004), the rate at 3 months was similar (2.3% for Aveir and 3.1% for Micra, P = 1.000). CONCLUSION: Aveir VR demonstrated satisfactory performance in this high-risk cohort. Pacing thresholds tend to improve to a greater extent than Micra after implantation. The PCT after fixation, even after a waiting period, has limited predictive value for the chronic threshold. Low-mapping PCT and high intraoperative impedance predict chronic low PCT.


Asunto(s)
Marcapaso Artificial , Realidad Virtual , Humanos , Resultado del Tratamiento , Estudios Retrospectivos , Diseño de Equipo , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos
9.
Europace ; 26(7)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38812433

RESUMEN

AIMS: Significant changes in tricuspid regurgitation (TR) and mitral regurgitation (MR) post-cardiac implantable electronic devices (CIEDs) are increasingly recognized. However, uncertainty remains as to whether the risk of CIED-associated TR and MR differs with right ventricular pacing (RVP) via CIED with trans-tricuspid RV leads, compared with cardiac resynchronization therapy (CRT), conduction system pacing (CSP), and leadless pacing (LP). The study aims to synthesize extant data on risk and prognosis of significant post-CIED TR and MR across pacing strategies. METHODS AND RESULTS: We searched PubMed, EMBASE, and Cochrane Library databases published until 31 October 2023. Significant post-CIED TR and MR were defined as ≥ moderate. Fifty-seven TR studies (n = 13 723 patients) and 90 MR studies (n = 14 387 patients) were included. For all CIED, the risk of post-CIED TR increased [pooled odds ratio (OR) = 2.46 and 95% CI = 1.88-3.22], while the risk of post-CIED MR reduced (OR = 0.74, 95% CI = 0.58-0.94) after 12 and 6 months of median follow-up, respectively. Right ventricular pacing via CIED with trans-tricuspid RV leads was associated with increased risk of post-CIED TR (OR = 4.54, 95% CI = 3.14-6.57) and post-CIED MR (OR = 2.24, 95% CI = 1.18-4.26). Binarily, CSP did not alter TR risk (OR = 0.37, 95% CI = 0.13-1.02), but significantly reduced MR (OR = 0.15, 95% CI = 0.03-0.62). Cardiac resynchronization therapy did not significantly change TR risk (OR = 1.09, 95% CI = 0.55-2.17), but significantly reduced MR with prevalence pre-CRT of 43%, decreasing post-CRT to 22% (OR = 0.49, 95% CI = 0.40-0.61). There was no significant association of LP with post-CIED TR (OR = 1.15, 95% CI = 0.83-1.59) or MR (OR = 1.31, 95% CI = 0.72-2.39). Cardiac implantable electronic device-associated TR was independently predictive of all-cause mortality [pooled hazard ratio (HR) = 1.64, 95% CI = 1.40-1.90] after median of 53 months. Mitral regurgitation persisting post-CRT independently predicted all-cause mortality (HR = 2.00, 95% CI = 1.57-2.55) after 38 months. CONCLUSION: Our findings suggest that, when possible, adoption of pacing strategies that avoid isolated trans-tricuspid RV leads may be beneficial in preventing incident or deteriorating atrioventricular valvular regurgitation and might reduce mortality.


Asunto(s)
Desfibriladores Implantables , Insuficiencia de la Válvula Mitral , Marcapaso Artificial , Insuficiencia de la Válvula Tricúspide , Humanos , Estimulación Cardíaca Artificial/efectos adversos , Terapia de Resincronización Cardíaca/efectos adversos , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Marcapaso Artificial/efectos adversos , Pronóstico , Factores de Riesgo , Insuficiencia de la Válvula Tricúspide/etiología , Insuficiencia de la Válvula Tricúspide/mortalidad , Insuficiencia de la Válvula Tricúspide/fisiopatología
10.
Pacing Clin Electrophysiol ; 47(4): 554-557, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-37377404

RESUMEN

The strategy after battery depletion was not established in Micra leadless pacemaker system (Micra). There are still some concerns in the 2nd Micra implantation, such as the mechanical interaction between both devices. The position of the 2nd Micra should be placed apart from the 1st Micra. We present a case of 1st Micra battery depletion who successfully underwent the 2nd Micra implantation under the intracardiac echo guidance. In our case, intracardiac echo was a very effective tool for confirming the location of Micra implantation.


Asunto(s)
Marcapaso Artificial , Humanos , Resultado del Tratamiento , Diseño de Equipo , Corazón , Ecocardiografía
11.
Pacing Clin Electrophysiol ; 47(8): 1061-1064, 2024 08.
Artículo en Inglés | MEDLINE | ID: mdl-38291888

RESUMEN

A 41-year-old male presented with syncope whilst eating and was subsequently demonstrated to have recurrent symptomatic sinus pauses whilst swallowing. Following the exclusion of structural heart disease, he was diagnosed with swallow syncope, an uncommon variant of neurocardiogenic syncope. To avoid long-term complications of a transvenous pacemaker, the case was managed with a leadless pacemaker which resulted in complete resolution of symptoms.


Asunto(s)
Deglución , Marcapaso Artificial , Síncope , Humanos , Masculino , Adulto , Síncope/terapia , Síncope/etiología , Diseño de Equipo , Electrocardiografía
12.
Pacing Clin Electrophysiol ; 47(8): 1124-1127, 2024 08.
Artículo en Inglés | MEDLINE | ID: mdl-38809030

RESUMEN

OBJECTIVE: This study evaluates the feasibility and efficacy of implanting a leadless pacemaker at the right atrial appendage (RAA) in a preclinical minipig model, aiming to address the limitations of atrial pacing with current leadless devices like the Medtronic Micra, which is typically used for right ventricular implantation. METHODS: Four minipigs, each with a median body weight of 45.8 ± 10.0 kg, underwent placement of the Micra transcatheter pacing system (TPS) via the right femoral vein into the RAA apex. The pacing performance was assessed over 1-week (short-term) and 3-month (long-term) periods. OUTCOMES: The initial findings indicated successful implantation, with satisfactory intrinsic R-wave amplitudes and pacing threshold. In the following period, the sensitivity, threshold, and impedance were stable with time. Notably, upon explanation at 3 months, a deep myocardial penetration by the device was observed, necessitating a redesign for safe long-term use in a growing subject's heart. CONCLUSION: While initial results suggest that RAA apex placement of the Micra TPS is promising for potential inclusion in a dual-chamber pacing system, the issue of myocardial penetration highlights the need for device redesign to ensure safety and effectiveness in long-term applications.


Asunto(s)
Apéndice Atrial , Diseño de Equipo , Marcapaso Artificial , Porcinos Enanos , Animales , Porcinos , Apéndice Atrial/cirugía , Estudios de Factibilidad , Estimulación Cardíaca Artificial/métodos
13.
Artículo en Inglés | MEDLINE | ID: mdl-38761054

RESUMEN

The pacing threshold is important for leadless pacemakers, as the pacing output has a significant impact on battery longevity. Acute pacing rate-dependent threshold increases have also been reported with leadless pacemakers. In the present case, we experienced a case in which the threshold, which had been raised in the acute phase, once showed a tendency to improve, but then worsened again. And, as in previous reports, thresholds improved completely in the chronic phase. Repeated retrieval and reimplantation of leadless pacemakers increases the likelihood of fatal complications, so being aware of such phenomenon may prevent unnecessary procedure and complications.

14.
Pacing Clin Electrophysiol ; 47(2): 256-259, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-37208974

RESUMEN

INTRODUCTION: Micra AV Transcatheter Pacing System (TPS) represents an innovative second-generation leadless pacemaker which represents an effective alternative to conventional devices in selected cases. Intrinsic malfunctions of these devices are rare, requiring sometimes their retrieval. When performed in experienced centers, this procedure is safe. CASE PRESENTATION: We describe a case of sudden battery malfunction of a Micra AV TPS, which required the extraction and the placement of a new pacing system in the right ventricle. DISCUSSION: This case, which has never been reported, highlights the need to a careful fluoroscopic evaluation and the usefulness of remote monitoring.


Asunto(s)
Arritmias Cardíacas , Marcapaso Artificial , Humanos , Resultado del Tratamiento , Diseño de Equipo , Marcapaso Artificial/efectos adversos , Estimulación Cardíaca Artificial
15.
Artículo en Inglés | MEDLINE | ID: mdl-39161131

RESUMEN

BACKGROUND: Transvenous lead extraction (TLE) for cardiovascular implantable electronic device (CIED)-related infections has increased. The incidence of TLE in nonagenarians is low, with limited reports outlining the outcomes of this procedure. Therefore, in this study, we aimed to clarify the outcomes of TLE in nonagenarians. METHODS: Patients with TLE treated at our hospital between 2014 and 2023 were retrospectively examined; patient characteristics, device type, indications, procedures, complications, and clinical data of nonagenarians were analyzed. RESULTS: Of 12 patients with 24 leads (active fixation lead, n = 11; passive fixation lead, n = 13) who underwent TLE, the indication for TLE was infection (pocket infection, n = 8; sepsis, n = 4). Methicillin-resistant Staphylococcus epidermidis was the most frequently identified causative agent (n = 4). The median patient age was 91 years; five patients were female. The median lead dwell time was 9 years. Excimer laser sheath (16 leads), mechanical sheath (five leads), Evolution RL (one lead), and manual traction (two leads) were employed in TLE. The procedure was successful in all patients, and only one had a minor complication. Six patients required CIED re-implantation, and leadless pacemakers were selected for five patients. The 30-day mortality after TLE was 0%. CONCLUSION: TLE can be safely performed in nonagenarians. The decision to perform TLE should not be based on old age alone; the suitability of removing infected CIEDs should be determined based on each patient's condition.

16.
J Cardiothorac Vasc Anesth ; 38(8): 1641-1649, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38876815

RESUMEN

This special article is a continuation of an annual series for the Journal of Cardiothoracic and Vascular Anesthesia, highlighting the latest developments in the field of electrophysiology, particularly concerning cardiac anesthesiologists. The selected topics in the specialty for 2023 include consensus statements on left atrial appendage closure, outcomes in patients with atrial fibrillation and heart failure after ablation, further developments in the field of pulse field ablation, alternate defibrillation strategies for refractory ventricular fibrillation, updates on conduction system pacing, new devices such as the Aurora EV system and AVEIR leadless pacemaker system, artificial intelligence and its use in electrocardiogram-based diagnosis and latest evidence regarding the impact of anesthetic techniques on patient outcomes undergoing electrophysiology procedures.


Asunto(s)
Fibrilación Atrial , Humanos , Fibrilación Atrial/terapia , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Electrofisiología/métodos , Electrofisiología/tendencias
17.
Curr Cardiol Rep ; 26(8): 789-799, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38869811

RESUMEN

BACKGROUND: Leadless pacemakers (LPs) are promising alternatives to traditional transvenous pacemakers (TVPs), but their comparative effectiveness and safety in clinical outcomes remain uncertain. METHODS: We systematically searched PubMed, Embase, Scopus, Cochrane, and ClinicalTrials.gov for studies comparing LPs and TVPs. A restricted maximum likelihood random-effects model was used for all outcomes. Heterogeneity was assessed using I2 statistics. We performed a subgroup analysis with studies with multivariate-adjusted data. RESULTS: We included 21 studies involving 47,229 patients, of whom 12,199 (25.8%) underwent LP implantation. Compared with TVPs, LPs were associated with a significantly lower risk of overall complications (OR 0.61; 95% CI 0.45-0.81; p < 0.01), dislodgement (OR 0.34; 95% CI 0.20-0.56; p < 0.01), and pneumothorax (OR 0.27; 95% CI 0.16-0.46; p < 0.01). No significant difference in all-cause mortality was observed in the overall analysis (OR 1.43; 95% CI 0.65-3.15; p = 0.35) and in studies with multivariate-adjusted data (OR 1.34; 95% CI 0.65-2.78; p = 0.43). However, LPs were associated with a higher risk of pericardial effusion (OR 2.47; 95% CI 1.39-4.38; p < 0.01) and cardiac tamponade (OR 3.75; 95% CI 2.41-5.83; p < 0.01). LPs also demonstrated a lower pacing capture threshold (MD -0.19 V; 95% CI [-0.23 V]-[-0.16 V]; p < 0.01), but no significant difference in impedance (MD 32.63 ohms; 95% CI [-22.50 ohms]-[87.76 ohms]; p = 0.25). CONCLUSIONS: These findings suggest that LPs were associated with lower overall complication rates and similar effectiveness to TVPs. However, randomized controlled trials are warranted to validate these results.


Asunto(s)
Marcapaso Artificial , Humanos , Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial/efectos adversos , Diseño de Equipo , Complicaciones Posoperatorias , Resultado del Tratamiento
18.
Curr Cardiol Rep ; 26(5): 331-338, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38492178

RESUMEN

PURPOSE OF REVIEW: Tricuspid regurgitation is a commonly encountered valvular pathology in patients with trans-tricuspid pacing or implantable cardioverter-defibrillator leads. Transcatheter tricuspid valve interventions are increasingly performed in patients at high surgical risk. Implantation of these valves can lead to the "jailing" of a trans-tricuspid lead. This practice carries both short- and long-term risks of lead failure and subsequent infection without the ability to perform traditional transvenous lead extraction. Herein, this manuscript reviews available therapeutic options for lead management in patients undergoing transcatheter tricuspid valve interventions. RECENT FINDINGS: The decision to jail a lead may be appropriate in certain high-risk cases, though extraction may be a better option in most cases given the variety of options for re-implant, including leadless pacemakers, valve-sparing systems, epicardial leads, leads placed directly through prosthetic valves, and the completely subcutaneous implantable-defibrillator. A growing number of patients meet the requirement for CIED implantation in the United States. A significant proportion of these patients will have tricuspid valve dysfunction, either related to or independent of their transvenous lead. As with any percutaneous intervention that has shown efficacy, the role of TTVI is also likely to increase as this therapy advances beyond the investigational phase. As such, the role of the heart team in the management of these patients will be increasingly critical in the years to come, and in those patients that have pre-existing CIED leads, we advocate for the involvement of an electrophysiologist in the heart team.


Asunto(s)
Desfibriladores Implantables , Implantación de Prótesis de Válvulas Cardíacas , Marcapaso Artificial , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Cateterismo Cardíaco/métodos , Estimulación Cardíaca Artificial/métodos , Prótesis Valvulares Cardíacas , Remoción de Dispositivos/métodos
19.
Indian Pacing Electrophysiol J ; 24(4): 204-206, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38697395

RESUMEN

Leadless pacemakers have provided new treatment modalities that can be especially useful in patients with complex cardiac anatomy and contraindications toward other pacemaker approaches. The Aveir™ single-chamber (VR) leadless pacemaker (LP) (Abbott Laboratories, Chicago, IL) is a recently approved device that can be placed in the right ventricle for patients with bradycardia. In this case, we present a novel use for the device through placement in the atrium to control atrial flutter in a patient with a hypoplastic right ventricle.

20.
Artículo en Inglés | MEDLINE | ID: mdl-39241910

RESUMEN

Leadless pacemakers have demonstrated potential as a transvenous pacing option in Adult Congenital Heart Disease patients. Aveir™ single-chamber (VR) leadless pacemakers have demonstrated safety in patients without congenital heart disease in a dual chamber approach. We present a case of dual-chamber pacing using the Aveir dual-chamber (DR) leadless pacemaker in a patient with repaired dextro-transposition of the great arteries with ventricular septal defect (VSD) surgical closure. A 26-year-old male patient with a history of transposition of the great arteries status post arterial switch and VSD repair neonatally had complicated second degree atrioventricular block and sinus node dysfunction necessitating pacemaker placement. Epicardial single-chamber ventricular pacemaker was placed neonatally, which was switched to dual-chamber pacemaker at age 17 due to malfunction. Recent fracture of pacemaker leads led to implantation of new dual chamber leadless pacemaker. Removal of previous pacemaker leads via mechanical extraction occurred and implantation of Aveir DR leadless pacemaker was performed under anesthesia via right femoral vein access without complication. Follow-up demonstrated Aveir VR threshold of 1.0V@0.2 ms, R-wave of 8.9mV, impedance of 490Ω, and the Aveir AR threshold of 0.75V@0.2 ms, P-wave of 3.7mV, and impedance of 400Ω. This case demonstrates safety and efficacy of dual chamber leadless pacemaker implantation in an ACHD patient.