Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Medicina (Kaunas) ; 59(10)2023 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-37893445

RESUMEN

Background and Objectives: The proximal humeral fracture (PHF) is one of the most common fractures in elderly patients. A PHF might influence the quality of life (QoL) on several different levels, especially in elderly patients, but it is unclear which treatment option results in a better QoL outcome. Therefore, we aimed to systematically review the current literature for studies that have analyzed the QoL and pain of elderly patients treated either surgically or non-operatively for PHF. Materials and Methods: A comprehensive search of the literature was performed in the PubMed database from January to April 2023. Studies describing the QoL or the level of pain of patients older than 60 years with the EuroQoL-5 Dimension (EQ-5D) score or the visual analogue scale (VAS) after the treatment of PHF, either non-operatively (non-OP), with open-reduction and internal fixation using a locking plate (LPF), or with reverse total shoulder arthroplasty (RTSA) were included. Twelve studies were analyzed descriptively and the individual risk of bias was assessed using the ROB2 and ROBINS-I tools. Results: A total of 12 studies with 712 patients at baseline were included (78% female sex, mean age 75.2 years). The reported VAS scores at 12-month follow-up (FU) ranged from 0.7 to 2.5. The calculated overall mean VAS score across all studies showed a decreasing tendency for all treatments, with an increasing FU time up to 12 months after PHF. None of the studies reported any significant differences of the EQ-5D across the groups. The overall calculated EQ-5D indices showed an increasing trend after 6-8 weeks FU, but did not differ significantly between the three treatments. Conclusions: In conclusion, the current literature suggests that there are no clinically important differences between the QoL or pain in elderly patients with PHF after non-operative treatment or surgical treatment with LPF or RTSA. However, the number of studies and level of evidence is rather low and further trials are urgently needed.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Fracturas del Hombro , Humanos , Femenino , Anciano , Masculino , Resultado del Tratamiento , Calidad de Vida , Artroplastía de Reemplazo de Hombro/métodos , Fijación Interna de Fracturas/efectos adversos , Dolor/etiología , Fracturas del Hombro/complicaciones , Fracturas del Hombro/cirugía , Estudios Retrospectivos
2.
Pak J Med Sci ; 39(4): 1040-1044, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37492340

RESUMEN

Objective: To analyze the effects of sodium hyaluronate administration on the serum levels of antioxidase, substance P (SP), and neuropeptide Y (NPY) in patients undergoing locking plate fixation (LPF) for tibial plateau fractures (TPF). Methods: We retrospectively analyzed the records of 66 patients with TPF who received treatment in the Beijing Chao-yang Hospital[PJMS1][2] from February 2017 to August 2020. According to the treatment records, 33 patients underwent LPF surgery (control-group), and 33 patients underwent LPF plus sodium hyaluronate treatment (observation-group). The levels of antioxidant enzymes (superoxide dismutase (SOD), catalase (CAT) and total antioxidant capacity (TAC)), SP and NPY. Results: Seven days after LPF operations, both groups showed lower levels of SOD, CAT, and TAC compared to pre-surgery levels, while levels of SP and NPY were higher. However, the observation group showed higher levels of SOD, CAT, and TAC compared to the control group, and lower levels of SP and NPY in the control group (P<0.05). Conclusion: The treatment of TPF with LPF plus sodium hyaluronate administration has been shown to effectively reduce oxidative stress reactions, improve SP and NPY levels.[PJMS3][4].

3.
Foot Ankle Surg ; 29(1): 97-102, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36473825

RESUMEN

BACKGROUND: The optimal treatment of displaced intra-articular calcaneal fractures (DIACF) is controversial. This study compared the fixation stability of screws and locking plates in DIACF treated via the sinus tarsi approach (STA). METHODS: We retrospectively evaluated 118 DIACF cases treated via STA and extracted data that could affect treatment outcomes. Loss of Böhler's angle after surgery was measured to compare fixation stability. RESULTS: The loss of Böhler's angles was significantly smaller in the locking plate group than in the screw group (2.6 ± 2.7º vs. 5.6 ± 5.3º, P < 0.01). There was no difference in the clinical outcomes between the groups. On multivariate logistic regression analysis, screw fixation was significantly associated with loss of Böhler's angle by> 10º (odds ratio, 8.63; 95% confidence interval, 1.16-64.4; P < 0.05). CONCLUSIONS: Locking plate fixation is more reliable than screw fixation for preventing correction loss in DIACF treated via STA. LEVEL OF EVIDENCE: III.


Asunto(s)
Traumatismos del Tobillo , Calcáneo , Fracturas Óseas , Fracturas Intraarticulares , Humanos , Talón , Estudios Retrospectivos , Fijación Interna de Fracturas , Calcáneo/cirugía , Fracturas Intraarticulares/diagnóstico por imagen , Fracturas Intraarticulares/cirugía , Estudios de Seguimiento , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Resultado del Tratamiento , Placas Óseas , Tornillos Óseos
4.
J Hand Surg Am ; 47(1): 62.e1-62.e7, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34607738

RESUMEN

PURPOSE: This study aimed to evaluate the efficacy of hand therapy after volar locking plate fixation of distal radius fractures in middle-aged to elderly women. METHODS: Fifty-seven patients diagnosed with distal radius fractures who had undergone volar plate fixation were enrolled in a prospective, randomized controlled trial. Patients were randomized into the hand therapy and independent exercise (IE) groups, in which they exercised independently under the surgeon's direction with and without hand therapy, respectively. The primary outcome was the functional outcome measured using the Disability of Arm, Shoulder, and Hand questionnaire after 6 weeks. The secondary outcomes were functional outcomes measured using the Patient-Rated Wrist Evaluation questionnaire, active and passive ranges of motion (ROMs), grip strength, key pinch strength, and pain measured on a visual analog scale. Patients were followed up in the outpatient department at 2, 4, 6, and 8 weeks and at 3 and 6 months. RESULTS: The Disability of Arm, Shoulder, and Hand scores were significantly lower in the hand therapy group at 6 weeks after surgery (12.5 vs 19.4 in the IE group). The postoperative visual analog scale pain scores were significantly lower in the hand therapy group at 2, 4, and 6 weeks (10.2 vs 17.6 in the IE group). The active ROM of the wrist flexion-extension arc at 2, 4, 6, and 8 weeks; active ROM of the pronation-supination arc at 6 and 8 weeks; and passive ROM of the wrist flexion-extension arc at 2, 4, and 8 weeks were significantly greater in the hand therapy group. CONCLUSIONS: Hand therapy improved the outcomes after volar locking plate fixation for distal radius fracture in middle-aged to elderly women at 8 weeks after surgery. No significant between-group differences were observed in any functional outcome measure at 6 months after surgery, as previously reported. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic II.


Asunto(s)
Fracturas del Radio , Anciano , Placas Óseas , Femenino , Fijación Interna de Fracturas , Fuerza de la Mano , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Fracturas del Radio/cirugía , Rango del Movimiento Articular , Resultado del Tratamiento
5.
Arch Orthop Trauma Surg ; 142(1): 91-97, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32948917

RESUMEN

PURPOSE: To evaluate the potential of locking compression plate with intramedullary fibular allograft in managing proximal humeral fractures with an unstable medial column. METHODS: Between March 2007 and March 2015, we retrospectively analyzed 63 patients who underwent locking plate fixation for proximal humeral fracture with an unstable medial column. All patients were assigned into group 1 (patients treated with locking plate) and group 2 (patients treated with locking plate with intramedullary fibular allograft). Groups 1 and 2 were composed of 29 and 34 patients, respectively. We analyzed bone union, the neck-shaft angle, the Constant score, the range of motion, and complications. RESULTS: The mean average bone union time of the patients was 13.9 weeks in group 1 and 11.3 weeks in group 2. The average Constant score was 67.4 in group 1 and 73.6 in group 2 (p < 0.05). The mean preoperative NSA, postoperative NSA, and NSA at the last follow-up were 104.4°, 125.8°, and 115.8°, respectively, in group 1, and 109.0°, 130.3°, and 127.1°, respectively, in group 2. The mean forward flexion, abduction, external rotation, and internal rotation were 109.0°, 48.2°, 34.0°, and L5, respectively, in group 1, and 127.5°, 118.2°, 38.7°, and L1, respectively, in group 2. In group 1, avascular necrosis occurred in one patient and screw cutout in two patients. In group 2, screw cutout occurred in one patient. CONCLUSION: In patients aged over 65 years with proximal humeral fractures, an unstable medial column was associated with poor clinical results owing to varus collapse. To prevent this, an intramedullary fibular allograft was used, and radiologic and clinical results were better with this approach than with a locking plate alone. Therefore, locking plate fixation using a fibular allograft is one of the possible treatments for patients with an unstable medial column.


Asunto(s)
Fijación Interna de Fracturas , Fracturas del Hombro , Anciano , Aloinjertos , Placas Óseas , Humanos , Estudios Retrospectivos , Fracturas del Hombro/diagnóstico por imagen , Fracturas del Hombro/cirugía , Resultado del Tratamiento
6.
Arch Orthop Trauma Surg ; 142(11): 3247-3254, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34432097

RESUMEN

INTRODUCTION: Surgical treatment of complex humeral head fractures in the elderly is challenging due to osteoporotic bone, comorbidities and reduced compliance. The treatment strategy (reconstruction versus replacement) should allow for a functional aftercare and result in a high patient satisfaction. Major complications leading to surgical revision are crucial and should be avoided. The purpose of this study was to analyse the major complication rate leading to surgical revision and the patient-based outcome in complex humeral head fractures of the elderly population treated either using locking plate fixation (LCP) or reversed total shoulder arthroplasty (rTSA). MATERIALS AND METHODS: All patients older than 65 years surgically treated due to a four-part fracture of the proximal humerus between 2003 and 2015 were enrolled in our retrospective study. Major complications and revision rates were recorded and functional outcome was assessed using the Munich Shoulder Questionnaire (MSQ) allowing for qualitative self-assessment of the Shoulder Pain and Disability Index (SPADI), of the Disability of the Arm, Shoulder and Hand (DASH) score and of the Constant Score. RESULTS: A cohort of 103 patients with a mean age of 73.4 ± 6.2 years suffering from four-part fractures of the humeral head were enrolled. 63 patients were treated using the LCP fixation compared to 40 rTSAs. There were no significant differences in the patient-reported functional outcome. The revision rate was significantly higher in the LCP group (10/63; 15.9%) compared to the rTSA group (1/40; 2.5%). Reasons for revision were avascular head necrosis, cut-out of screws, secondary dislocation of the greater tuberosity and hypersensitivity to metal. CONCLUSIONS: Reversed total shoulder arthroplasty and locking plate fixation are both established surgical procedures for the management of complex proximal humerus fractures in the elderly leading to similar functional results. However the revision rate in the rTSA group was significantly lower. Primary rTSA should, therefore, be favoured in multimorbid elderly patients with an increased complication risk to avoid repeated anaesthesia.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Fracturas del Hombro , Anciano , Artroplastía de Reemplazo de Hombro/métodos , Placas Óseas/efectos adversos , Fijación Interna de Fracturas/métodos , Humanos , Cabeza Humeral/cirugía , Estudios Retrospectivos , Fracturas del Hombro/cirugía , Resultado del Tratamiento
7.
Arch Orthop Trauma Surg ; 142(7): 1557-1561, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33825039

RESUMEN

INTRODUCTION: The incidence of patella fracture is statistically low (0.5-1.5%) compared to other fractures of the extremities [Patella fractures 76(10):987-997, 2005]. In the latter research, patella fractures if treated surgically present an overall inferior functional outcome. Little is known about the influence of the postoperative patella height on the clinical outcome. Therefore, the aim of our study was to analyse the influence of the patella height on the patients' functional outcome after surgery. METHODS: In this retrospective study the in-house trauma register of our level I University trauma center was screened for patients suffering patella fractures treated surgically. Patella height of the same patients was evaluated on lateral X-rays using the Insall-Salvati Ratio (ISR). The patients' X-rays were analyzed at two time points for the ISR, whereas group A presents ISR data right after surgery and group B data at the latest follow up (minimum 6 weeks). The change of mean ISR at both time points was tested for significance. The functional outcome was measured by the "Munich Knee Questionaire" (MKQ). These MKQ results of different patella heights and fracture types were compared. RESULTS: The screening of our in-house trauma register revealed 375 patients between the years 2003 and 2016. Out of these 54 patients (34f, 20 m) were enrolled. In detail the follow-up time for ISR between group A and B accounted for a mean of 503.8 ± 655.7 days. The MKQ was assessed at a mean of 1367.0 ± 1042.8 days after surgery. According to the AO-classification 10% AO.34 type B and 90% AO.34 type C fractures were found. Group A showed in 9.1% a patella baja and in 27.3% a patella alta compared to group B presenting 20.0% patella baja and 14.5% patella alta. There was no significant difference in functional outcome referring to the MKQ in patella alta (MKQ 69.0% ± 18.2) or baja (MKQ 67.1% ± 17.9) (p = 0.9). No significant functional difference between AO34.type B (MKQ 74.5% ± 11.0) and AO34.type C fractures (MKQ 64.0% ± 15.0) resulted (p = 0.1). CONCLUSION: Our results demonstrate that different postoperative patella heights apparently do not influence the functional outcome in the short follow-up.


Asunto(s)
Fracturas Óseas , Traumatismos de la Rodilla , Fracturas Óseas/cirugía , Humanos , Articulación de la Rodilla/cirugía , Rótula , Estudios Retrospectivos , Resultado del Tratamiento
8.
Arch Orthop Trauma Surg ; 141(10): 1691-1699, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33108505

RESUMEN

INTRODUCTION: Calcaneal fractures account for 60-75% of all tarsal fractures and represent surgical challenges because of their frequency and complexity. Despite standardized procedures and new implants, literature reports high revision rates and unsatisfactory results. The study aims to describe the role of the surgeon with respect to the clinical outcome. METHODS: Between 2014 and 2017, 94 calcaneal fractures (all type AO C1-3) were re-examined in 86 patients (67 male and 19 female; mean age: 51 years). The treatment was always carried out by means of locking compression plate via the extensile lateral approach. A comparison was made between treatment by an experienced (ES) and less experienced surgeon (LES). Annually, the ES performed at least 30 procedures for calcaneus fracture treatment as compared to < 10 operations performed by the LES. RESULTS: The mean AOFAS, VAS FA, and Kiel Score in the ES group were 77.0 (SD 15.9), 69.0 (SD 18.8), and 65.0 (SD 20.6), respectively. The corresponding values in the LES group were 68.1 (SD 21.0), 60.3 (SD 22.4), and 53.0 (SD 21.9) (p < 0.05). The operation time was on average 14 min shorter in the ES group than the LES group (p < 0.05). CONCLUSION: The significantly better scores, along with shorter operation time, shorter duration of incapacity to work, and lower complication rate prove the importance of having an experienced surgeon perform complex intra-articular calcaneal fracture repairs. The extensile lateral approach is still considered the standard method. LEVEL OF EVIDENCE: Level III, comparative series.


Asunto(s)
Calcáneo , Fracturas Óseas , Fracturas Intraarticulares , Placas Óseas , Calcáneo/cirugía , Femenino , Fijación Interna de Fracturas , Fracturas Óseas/cirugía , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
9.
J Biomech Eng ; 142(8)2020 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-31913444

RESUMEN

Internal fixation with the use of locking plates is the standard surgical treatment for proximal humerus fractures, one of the most common fractures in the elderly. Screw cut-out through weak cancellous bone of the humeral head, which ultimately results in collapse of the fixed fracture, is the leading cause of failure and revision surgery. In an attempt to address this problem, surgeons often attach the plate with as many locking screws as possible into the proximal fragment. It is not thoroughly understood which screws and screw combinations play the most critical roles in fixation stability. This study conducted a detailed finite element analysis to evaluate critical parameters associated with screw cut-out failure. Several clinically relevant screw configurations and fracture gap sizes were modeled. Findings demonstrate that in perfectly reduced fracture cases, variation of the screw configurations had minor influence on mechanical stability of the fixation. The effects of screw configurations became substantial with the existence of a fracture gap. Interestingly, the use of a single anterior calcar screw was as effective as utilizing two screws to support the calcar. On the other hand, the variation in calcar screw configuration had minor influence on the fixation stability when all the proximal screws (A-D level) were filled. This study evaluates different screw configurations to further understand the influence of combined screw configurations and the individual screws on the fixation stability. Findings from this study may help decrease the risk for screw cut-out with proximal humerus varus collapse and the associated economic costs.


Asunto(s)
Análisis de Elementos Finitos , Fracturas del Hombro , Anciano , Fenómenos Biomecánicos , Placas Óseas , Fijación Interna de Fracturas , Humanos
10.
BMC Musculoskelet Disord ; 21(1): 800, 2020 Dec 02.
Artículo en Inglés | MEDLINE | ID: mdl-33267845

RESUMEN

BACKGROUND: Locking plate fixation is one of the treatment strategies for the management of proximal humeral fractures. However, stiffness after locking plate fixation is a clinical concern. The mechanical stiffness of the standard locking plate system may suppress the interfragmentary motion necessary to promote secondary bone healing by callus formation. The far cortical locking (FCL) technique was developed to address this limitation in 2005. FCL increases construct flexibility and promotes callus formation. Our study aimed to evaluate the clinical and radiological outcomes of the FCL technique when implemented in proximal humeral fracture management. Furthermore, we compared the surgical outcomes of FCL with those of the conventional bicortical locking (BCL) screw fixation technique. METHODS: Forty-five consecutive patients who had undergone locking fixation for proximal humeral fractures were included in this study. A proximal humeral locking plate (PHILOS) system with BCL screw fixation was used in the first 27 cases, and the periarticular proximal humeral locking plate with FCL screw fixation was used in the final 18 consecutive cases. Functional capacity was assessed using the constant score, American Shoulder and Elbow Surgeons (ASES) score, and range of motion. Radiographic outcomes were evaluated using the Paavolainen method of measuring the neck-shaft angle (NSA). RESULTS: No significant differences in clinical outcomes (ASES score, constant score, and range of motion) were found between the two groups. The union rate at 12 weeks was significantly higher in the FCL group (94.4%) than in the BCL group (66.7%, p = 0.006). No significant differences in NSA were found between the two treatment strategies. The complication rate was not significantly different between the two groups. CONCLUSIONS: When implemented in proximal humeral fractures, the FCL technique showed satisfactory clinical and radiological outcomes as compared with the conventional BCL technique. The bone union rate at 12 weeks after surgery was significantly higher in the FCL group than in the BCL group. However, no significant difference in the final bone union rate was found between the two groups.


Asunto(s)
Fracturas del Húmero , Fracturas del Hombro , Placas Óseas , Tornillos Óseos , Fijación Interna de Fracturas , Humanos , Fracturas del Hombro/diagnóstico por imagen , Fracturas del Hombro/cirugía , Resultado del Tratamiento
11.
J Shoulder Elbow Surg ; 29(11): 2190-2199, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32650077

RESUMEN

BACKGROUND: This study aimed to compare the functional and clinical outcomes between the deltoid split (DS) approach and the classic deltopectoral (DP) approach for locking plate fixation of proximal humerus fractures (PHF) in a prospective randomized multicenter study. METHODS: From 2007 to 2015, all patients with a PHF Neer II/III were invited to participate. Exclusion criteria were pre-existing pathology to the limb, patient refusing or too ill to undergo surgery, patient needing another type of treatment (nail, arthroplasty), and axillary nerve impairment. After consent, patients were randomized to one of the 2 treatments using the dark envelope method. Functional outcome was evaluated by validated questionnaires (12-Item Short Form Health Survey: version 2, Quick-DASH) with a minimum follow-up of 12 months. Complications were noted. RESULTS: A total of 85 patients (44 DS, 41 DP) were randomized (mean age of 62). Groups were equivalent in terms of age, gender, body mass index, severity of fracture, and preinjury scores. The mean follow-up was 26 months. All clinical outcome measures were in favor of the deltopectoral approach. Specifically, the Q-DASH and SF-12v2 were better in the DP group (12 vs. 26, P = .003 and 56 vs. 51, P = .049, respectively). There were more complications in DS patients, but they did not reach statistical significance. CONCLUSIONS: The primary hypothesis on the superiority of the deltoid split incision was rebutted. On the basis of our study, the DP approach seems to offer better function compared with the DS approach for fixation of Neer 2 and 3 PHF fractures fixed with a locking plate.


Asunto(s)
Placas Óseas , Fracturas del Hombro/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Músculo Deltoides , Femenino , Fijación Interna de Fracturas , Humanos , Masculino , Persona de Mediana Edad , Músculos Pectorales , Estudios Prospectivos , Encuestas y Cuestionarios , Resultado del Tratamiento , Adulto Joven
12.
Zhonghua Yi Xue Za Zhi ; 100(41): 3240-3245, 2020 Nov 10.
Artículo en Zh | MEDLINE | ID: mdl-33167111

RESUMEN

Objective: To compare the effect of intramedullary nail and locking plate in the treatment of proximal humeral fractures in the elderly. Methods: A total of 37 elderly patients with proximal humeral fractures were selected from April 2016 to June 2018 in Tianjin Hospital, including 13 males and 24 females, aged (66±5) years. The patients were divided into observation group (17 cases) and control group (20 cases) according to the random number table, and were treated with multiloc intramedullary nail and locking plate respectively. The operation time, blood loss, healing time of fractures, visual analogue scale of pain, Neer shoulder function score were recored and compared between the two groups. The data were compared with t test between the two groups. Results: The operation time of the observation group was shorter than that of the control group ((72±7) min vs (89±9) min, t=6.365, P<0.05); the intraoperative bleeding volume was lower than that of the control group ((56±6) ml vs (74±8) ml, t=7.923, P<0.05). The superior rate of shoulder function was 94.1%(16/17) in the observation group and 90.0%(18/20) in the control group (χ(2)=0.209, P>0.05). The VAS score of the observation group was lower than that of the control group on the first day after operation (t=4.706, P<0.05); the Neer shoulder function score of the observation group was higher than that of the control group on the sixth month after operation (81±8 vs 76±8, t=2.156, P<0.05). Six months after the operation, the valgus angle (19.21°±2.88°) of the observation group was larger than that of the control group (16.32°±2.63°, t=3.189, P<0.05), the humeral head varus angle (3.57°±0.47°), the humeral neck stem angle (139°±10°) was smaller than that of the others (5.24°±1.26°), (146°±13°) (t=5.159, 2.258, both P<0.05). There was no significant difference in shoulder function score and complication rate 12 months after operation between the two groups (both P>0.05). Conclusion: Both intramedullary nailing and locking plate can achieve better results in the treatment of proximal humeral fractures in the elderly, but the operation time of intramedullary nailing is shorter, the pain after operation is lighter and the recovery is faster.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas del Húmero , Fracturas del Hombro , Anciano , Placas Óseas , Femenino , Fijación Interna de Fracturas , Humanos , Masculino , Persona de Mediana Edad , Hombro , Fracturas del Hombro/cirugía , Resultado del Tratamiento
13.
Eur J Orthop Surg Traumatol ; 30(1): 75-81, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31456035

RESUMEN

PURPOSE: Sternal fractures are rare injuries and mostly treated non-operatively. In selected cases, internal fixation becomes necessary. No standard operative approach has been determined yet among experts. The aim of this study is to describe our treatment algorithm and results after operative stabilisation of sternal fractures with locking compression plates (LCP), mainly focusing on the functional outcome. METHODS: A retrospective cohort study was conducted. We included all patients after operative stabilisation of a sternal fracture between 2008 and 2016. Endpoints were the functional outcome using the Activities of Daily Living (ADL) score, pain analysed by the numeric rating scale (NRS), breathing ability, complications and implant removal. RESULTS: Eighteen out of 153 (12%) patients with a sternal fracture underwent operation. Three patients were lost to follow-up. Eleven out of 15 (73%) patients were treated with double straight LCP 3.5 mm implants and 4 (27%) patients with pre-countered LCP 3.5 mm implants. Mean follow-up was 57 months. The median ADL score was 1 (1-4), the median NRS was 0 (0-9), and respiratory complaints scored a median of 1 (1-4). No non-union, hardware failure or implant-related complication occurred. Post-operative complications were pneumonia (20%) and respiratory insufficiency (20%). Implants were removed in 4/15 (27%) patients; three times due to implant-related irritation, once on patient's request. CONCLUSION: Operative stabilisation of sternal fractures with double LCP 3.5 mm provides excellent long-term functional results and seems to be an appropriate option for internal fixation. The rate of post-operative complications is low; however, 27% had a second operation for implant removal.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas/instrumentación , Fracturas Óseas/cirugía , Cuidados Posoperatorios/rehabilitación , Esternón/lesiones , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Bases de Datos Factuales , Femenino , Fijación Interna de Fracturas/métodos , Curación de Fractura/fisiología , Fracturas Óseas/diagnóstico por imagen , Humanos , Puntaje de Gravedad del Traumatismo , Masculino , Persona de Mediana Edad , Cuidados Posoperatorios/métodos , Pronóstico , Enfermedades Raras , Estudios Retrospectivos , Suiza , Tomografía Computarizada por Rayos X/métodos , Centros Traumatológicos , Resultado del Tratamiento
14.
Arch Orthop Trauma Surg ; 139(8): 1069-1074, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30895465

RESUMEN

BACKGROUND: The aim of this study was to identify the effect of screw length on predictions of fixation failure in three-part proximal humeral fractures using a finite element-based osteosynthesis modelling toolkit. METHODS: A mal-reduced unstable three-part AO/OTA 11-B3.2 fracture with medial comminution was simulated in forty-two digitally processed proximal humeri covering a spectrum of bone densities and fixed with the PHILOS plate using three distal and six proximal locking screws. Four test groups were generated based on the screw tip to joint surface distance (TJD), with all proximal screws being shortened from 4 mm TJD to be 8, 12 or 16 mm TJD. Average bone strains around the screw tips, correlating with biomechanical cyclic cut-out-type failure, were evaluated in three physiological loading protocols representing simple shoulder motions. Six further groups were tested, where five of the proximal screws were inserted to 4 mm TJD and the sixth screw to 8 mm TJD. RESULTS: Exponential increases in the predicted risk of fixation failure were seen with increased tip-to-joint distances (p < 0.001). When one of the proximal screws was placed 8 mm from the joint, with the remaining five at 4 mm distance, significant increases (p < 0.001) were registered in the strains around the screw tips in all except the two superior screws. This effect was maximal around the calcar screws (p < 0.001) and for lower density samples (p < 0.001). CONCLUSIONS: These results suggest that longer screws provide reduced risk of cut-out failure, i.e. distalisation and/or varisation of the head fragment, and thus may decrease failure rates in proximal humeral fractures treated with angular stable plates. These findings require clinical corroboration and further studies to investigate the risk of screw perforation.


Asunto(s)
Tornillos Óseos , Simulación por Computador , Análisis de Elementos Finitos , Fijación Interna de Fracturas/métodos , Fracturas del Hombro/cirugía , Anciano , Anciano de 80 o más Años , Placas Óseas , Femenino , Fijación Interna de Fracturas/instrumentación , Fracturas Conminutas/diagnóstico por imagen , Fracturas Conminutas/cirugía , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Fracturas del Hombro/diagnóstico por imagen , Tomografía Computarizada por Rayos X
15.
Int Orthop ; 42(8): 1935-1942, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-28988333

RESUMEN

The surgical treatment of proximal humerus fractures remains controversial primarily due to the high complication rate associated with the available fixation methods. In an attempt to reduce the incidence of serious complications and subsequent poor clinical outcomes, proximal humerus locking plates have become popular but even these implants cannot overcome the risk of complications, especially those associated with loss of fracture reduction and screw cut-out/migration through the humeral head. In an attempt to address these issues, we have reviewed the literature, investigating the most likely causes for these predominantly mechanical complications and propose technical solutions.


Asunto(s)
Placas Óseas/efectos adversos , Tornillos Óseos/efectos adversos , Fijación Interna de Fracturas/efectos adversos , Complicaciones Posoperatorias/etiología , Fracturas del Hombro/cirugía , Fijación de Fractura/efectos adversos , Fijación Interna de Fracturas/métodos , Humanos , Incidencia , Factores de Riesgo , Resultado del Tratamiento
16.
Arch Orthop Trauma Surg ; 137(1): 63-71, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28005168

RESUMEN

INTRODUCTION: The high rigidity of metal implants may be a cause of failure after fixation of proximal humerus fractures. Carbon fiber-reinforced polyetheretherketone (PEEK) plates with a modulus similar to human cortical bone may help to overcome this problem. The present study assesses the biomechanical behavior of a PEEK plate compared with a titanium locking plate. MATERIALS AND METHODS: Unstable two- and three-part fractures were simulated in 12 pairs of cadaveric humeri and were fixed with either a PEEK or a titanium locking plate using a pairwise comparison. With an optical motion capture system, the stiffness, failure load, plate bending, and the relative motion at the bone-implant interface and at the fracture site were evaluated. RESULTS: The mean load to failure for two- and three-part fracture fixations was, respectively, 191 N (range 102-356 N) and 142 N (range 102-169 N) in the PEEK plate group compared with 286 N (range 191-395 N) and 258 N (range 155-366 N) in the titanium locking plate group. The PEEK plate showed significantly more bending in both the two- and three-part fractures (p < 0.05), an increased relative motion at the bone-implant interface and lower stiffness values (p < 0.05). CONCLUSION: In this biomechanical study on unstable proximal humerus fractures, fixation with a PEEK plate showed lower fixation strength and increased motion at the bone-implant interface compared with a titanium locking plate.


Asunto(s)
Materiales Biocompatibles , Placas Óseas , Fijación Interna de Fracturas/instrumentación , Cetonas , Polietilenglicoles , Fracturas del Hombro/cirugía , Titanio , Anciano , Anciano de 80 o más Años , Benzofenonas , Fenómenos Biomecánicos , Cadáver , Carbono , Fibra de Carbono , Femenino , Humanos , Masculino , Polímeros , Estrés Mecánico
17.
Unfallchirurg ; 119(9): 723-31, 2016 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-27481355

RESUMEN

Fractures of the distal radius in elderly patients increasingly contribute to the workload in emergency departments worldwide. There is still no consensus about the best treatment option, e. g. closed reduction and cast stabilization, percutaneous pinning, external fixation or open reduction and internal fixation with volar locking plates (ORIF). In addition, the influence of pharmacological antiosteoporotic treatment (e. g. bisphosphonates) is unclear. In this overview five comparative studies were analyzed, which had been identified in a previous systematic review. The evaluation included 3 cohort studies and 2 randomized trials enrolling a total of 515 patients. A clinical or statistical advantage of ORIF over conservative treatment with respect to DASH scores 12 months after the index fracture event could not be demonstrated with a mean difference of 0.25 (95 % confidence interval CI -0.57-1.07). According to current best scientific evidence from preclinical and clinical investigations, antiosteoporotic medication does not have an unfavorable influence on fracture healing and should be continued due to its proven effectiveness in reducing subsequent osteoporotic fractures. Following distal radius fractures in elderly patients with clinical risk factors, an osteoporosis screening should be routine practice and a specific therapy should be initiated if the fracture risk is increased.


Asunto(s)
Conservadores de la Densidad Ósea/administración & dosificación , Fijación Interna de Fracturas/métodos , Inmovilización/métodos , Fracturas Osteoporóticas/prevención & control , Fracturas Osteoporóticas/terapia , Traumatismos de la Muñeca/terapia , Placas Óseas , Moldes Quirúrgicos , Terapia Combinada/métodos , Medicina Basada en la Evidencia , Fijación Interna de Fracturas/instrumentación , Humanos , Fracturas Osteoporóticas/diagnóstico , Resultado del Tratamiento , Traumatismos de la Muñeca/diagnóstico
18.
J Shoulder Elbow Surg ; 24(8): 1282-8, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25704209

RESUMEN

BACKGROUND: A radiolucent carbon fiber-reinforced polyetheretherketone (CFR-PEEK) plate was recently introduced for fixation of proximal humerus fractures. Prospective clinical and radiographic results of patients treated with a CFR-PEEK plate are compared with those of patients treated with a conventional locking plate. METHODS: Twenty-nine patients (mean age, 66 years) were treated with a CFR-PEEK plate for a 3- or 4-part proximal humerus fracture. Patients were clinically and radiographically re-examined at 6 weeks, 6 months, 12 months, and 24 months with the Simple Shoulder Test, Constant-Murley score (CMS), and Oxford Shoulder Score (OSS) as well as with simple radiographs. In addition, results were compared with a matched group of patients treated with a conventional locking plate. RESULTS: At the final follow-up examination at 24 months, patients achieved a mean Simple Shoulder Test score of 58%, a mean CMS of 71.3 points (range, 44-97), and a mean OSS of 27.4 points (range, 8-45). Bone union was confirmed in all patients. Compared with patients treated with the conventional locking plate, patients treated with the CFR-PEEK plate achieved significantly better results with regard to the CMS and the OSS (P = .038 and .029, respectively). Furthermore, loss of reduction with subsequent varus deformity was less frequently observed in the CFR-PEEK plate group. CONCLUSION: Fixation of proximal humerus fractures with a CFR-PEEK plate provides satisfying clinical and radiographic results after 2 years of follow-up. The results are comparable to those achieved with conventional locking plates.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas/métodos , Húmero/cirugía , Cetonas , Polietilenglicoles , Fracturas del Hombro/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Benzofenonas , Femenino , Humanos , Húmero/diagnóstico por imagen , Húmero/lesiones , Masculino , Persona de Mediana Edad , Polímeros , Estudios Prospectivos , Radiografía , Fracturas del Hombro/diagnóstico por imagen , Adulto Joven
19.
J Shoulder Elbow Surg ; 24(12): 1968-73, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26255200

RESUMEN

BACKGROUND: Shear forces at the bone-implant interface lead to a loss of reduction after locking plate fixation of proximal humeral fractures. The aim of the study was to analyze the roles of medial support screws and screw augmentation in failure loads and motion at the bone-implant interface after locking plate fixation of proximal humeral fractures. METHODS: Unstable 3-part fractures were simulated in 6 pairs of cadaveric humeri and were fixed with a DiPhos-H locking plate (Lima Corporate, Udine, Italy). An additional medial support screw was implanted in 1 humerus of every donor. The opposite humerus was stabilized with a medial support screw and additional bone cement augmentation of the 2 anteriorly directed head screws. Specimens were loaded in the varus bending position. Stiffness, failure loads, plate bending, and the motion at the bone-implant interface were evaluated using an optical motion capture system. RESULTS: The mean load to failure was 669 N (standard deviation [SD], 117 N) after fixation with medial support screws alone and 706 N (SD, 153 N) after additional head screw augmentation (P = .646). The initial stiffness was 453 N/mm (SD, 4.16 N/mm) and 461 N/mm (SD, 64.3 N/mm), respectively (P = .594). Plate bending did not differ between the 2 groups. However, motion at the bone-implant interface was significantly reduced after head screw augmentation (P < .05). CONCLUSION: The addition of bone cement to augment anteriorly directed head screws does not increase stiffness and failure loads but reduces motion at the bone-implant interface. Thus, the risk of secondary dislocation of the head fragment may be reduced.


Asunto(s)
Placas Óseas , Tornillos Óseos , Interfase Hueso-Implante/fisiopatología , Fijación Interna de Fracturas/instrumentación , Fracturas del Hombro/cirugía , Anciano , Fenómenos Biomecánicos , Cementos para Huesos , Interfase Hueso-Implante/diagnóstico por imagen , Cadáver , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fracturas del Hombro/diagnóstico por imagen , Fracturas del Hombro/fisiopatología , Tomografía Computarizada por Rayos X
20.
Clin Cases Miner Bone Metab ; 12(Suppl 1): 55-8, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-27134634

RESUMEN

Distal femoral fractures have typically a bimodal occurrence: in young people due to a high-energy trauma and in older people related to a low-energy trauma. These fractures are associated to a very high morbidity and mortality in elderly. Distal femoral fractures might be treated with plates, intramedullary nails, external fixations, and prosthesis. However, difficulties in fracture healing and the rate of complications are important clinical issues. The purpose of this retrospective review was to present our experience in treatment of distal femoral fracture in a sample of older people in order to evaluate the technical pitfalls and strategies used to face up the fractures unsuccessfully treated with locking plates. We included people aged more than 65 years, with a diagnosis of distal femoral fracture, treated with locking plates. We considered 'unsuccessfully treated' the cases with healing problems or hardware failures. Of the 12 patients (9 females and 3 males; mean aged 68.75 ± 3.31 years) included, we observed 3 'unsuccessfully cases', 2 due to nonunions and 1 due to an early hardware failure, all treated using a condylar blade plate with a bone graft. One patient obtained a complete fracture healing after 1 year and in the other cases there was a nonunion. We observed as most common technical pitfalls: inadequate plate lengthening, fracture bridging, and number of locking screws. The use of locking plates is an emerging technique to treat these fractures but it seems more challenging than expected. In literature there is a lack of evidences about the surgical management of distal femoral fractures that is still an important challenge for the orthopaedic surgeon that has to be able to use all the fixation devices available.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA