Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.301
Filtrar
Más filtros

Intervalo de año de publicación
1.
J Biol Chem ; 300(6): 107394, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38768813

RESUMEN

Periprosthetic osteolysis and subsequent aseptic loosening are the primary causes of failure following total joint arthroplasty. Wear particle-induced osteogenic impairment is recognized as an important contributing factor in the development of osteolysis, with endoplasmic reticulum (ER) stress emerging as a pivotal underlying mechanism. Hence, searching for potential therapeutic targets and agents capable of modulating ER stress in osteoblasts is crucial for preventing aseptic loosening. Kaempferol (KAE), a natural flavonol compound, has shown promising osteoprotective effects and anti-ER stress properties in diverse diseases. However, the influence of KAE on ER stress-mediated osteogenic impairment induced by wear particles remains unclear. In this study, we observed that KAE effectively relieved TiAl6V4 particles-induced osteolysis by improving osteogenesis in a mouse calvarial model. Furthermore, we demonstrated that KAE could attenuate ER stress-mediated apoptosis in osteoblasts exposed to TiAl6V4 particles, both in vitro and in vivo. Mechanistically, our results revealed that KAE mitigated ER stress-mediated apoptosis by upregulating the IRE1α-XBP1s pathway while concurrently partially inhibiting the IRE1α-regulated RIDD and JNK activation. Collectively, our findings suggest that KAE is a prospective therapeutic agent for treating wear particle-induced osteolysis and highlight the IRE1α-XBP1s pathway as a potential therapeutic target for preventing aseptic loosening.


Asunto(s)
Estrés del Retículo Endoplásmico , Endorribonucleasas , Quempferoles , Osteoblastos , Osteogénesis , Osteólisis , Proteínas Serina-Treonina Quinasas , Proteína 1 de Unión a la X-Box , Animales , Estrés del Retículo Endoplásmico/efectos de los fármacos , Quempferoles/farmacología , Proteínas Serina-Treonina Quinasas/metabolismo , Proteína 1 de Unión a la X-Box/metabolismo , Proteína 1 de Unión a la X-Box/genética , Ratones , Osteogénesis/efectos de los fármacos , Endorribonucleasas/metabolismo , Endorribonucleasas/genética , Osteoblastos/metabolismo , Osteoblastos/efectos de los fármacos , Osteólisis/metabolismo , Osteólisis/inducido químicamente , Osteólisis/patología , Osteólisis/tratamiento farmacológico , Apoptosis/efectos de los fármacos , Transducción de Señal/efectos de los fármacos , Masculino , Humanos , Ratones Endogámicos C57BL
2.
FASEB J ; 38(1): e23323, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38015031

RESUMEN

Low-intensity loading maintains or increases bone mass, whereas lack of mechanical loading and high-intensity loading decreases bone mass, possibly via the release of extracellular vesicles by mechanosensitive bone cells. How different loading intensities alter the biological effect of these vesicles is not fully understood. Dynamic fluid shear stress at low intensity (0.7 ± 0.3 Pa, 5 Hz) or high intensity (2.9 ± 0.2 Pa, 1 Hz) was used on mouse hematopoietic progenitor cells for 2 min in the presence or absence of chemical compounds that inhibit release or biogenesis of extracellular vesicles. We used a Receptor activator of nuclear factor kappa-Β ligand-induced osteoclastogenesis assay to evaluate the biological effect of different fractions of extracellular vesicles obtained through centrifugation of medium from hematopoietic stem cells. Osteoclast formation was reduced by microvesicles (10 000× g) obtained after low-intensity loading and induced by exosomes (100 000× g) obtained after high-intensity loading. These osteoclast-modulating effects could be diminished or eliminated by depletion of extracellular vesicles from the conditioned medium, inhibition of general extracellular vesicle release, inhibition of microvesicle biogenesis (low intensity), inhibition of ESCRT-independent exosome biogenesis (high intensity), as well as by inhibition of dynamin-dependent vesicle uptake in osteoclast progenitor cells. Taken together, the intensity of mechanical loading affects the release of extracellular vesicles and change their osteoclast-modulating effect.


Asunto(s)
Micropartículas Derivadas de Células , Vesículas Extracelulares , Animales , Ratones , Osteoclastos , Médula Ósea , Células Madre Hematopoyéticas , Vesícula
3.
Plant Mol Biol ; 114(4): 84, 2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-38995453

RESUMEN

Expansins are proteins without catalytic activity, but able to break hydrogen bonds between cell wall polysaccharides hemicellulose and cellulose. This proteins were reported for the first time in 1992, describing cell wall extension in cucumber hypocotyls caused particularly by alpha-expansins. Although these proteins have GH45 and CBM63 domains, characteristic of enzymes related with the cleavage of cell wall polysaccharides, demonstrating in vitro that they extend plant cell wall. Its participation has been associated to molecular processes such as development and growing, fruit ripening and softening, tolerance and resistance to biotic and abiotic stress and seed germination. Structural insights, facilitated by bioinformatics approaches, are highlighted, shedding light on the intricate interactions between alpha-expansins and cell wall polysaccharides. After more than thirty years of its discovery, we want to celebrate the knowledge of alpha-expansins and emphasize their importance to understand the phenomena of disassembly and loosening of the cell wall, specifically in the fruit ripening phenomena, with this state-of-the-art dedicated to them.


Asunto(s)
Pared Celular , Frutas , Proteínas de Plantas , Pared Celular/metabolismo , Frutas/metabolismo , Frutas/crecimiento & desarrollo , Frutas/genética , Proteínas de Plantas/metabolismo , Proteínas de Plantas/genética , Polisacáridos/metabolismo
4.
Emerg Infect Dis ; 30(3): 469-477, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38289719

RESUMEN

Total joint arthroplasty is a commonly used surgical procedure in orthopedics. Revision surgeries are required in >10% of patients mainly because of prosthetic joint infection caused by bacteria or aseptic implant loosening caused by chronic inflammation. Encephalitozoon cuniculi is a microsporidium, an obligate intracellular parasite, capable of exploiting migrating proinflammatory immune cells for dissemination within the host. We used molecular detection methods to evaluate the incidence of E. cuniculi among patients who had total hip or knee arthroplasty revision. Out of 49 patients, E. cuniculi genotypes I, II, or III were confirmed in joint samples from 3 men and 2 women who had implant loosening. Understanding the risks associated with the presence of microsporidia in periprosthetic joint infections is essential for proper management of arthroplasty. Furthermore, E. cuniculi should be considered a potential contributing cause of joint inflammation and arthrosis.


Asunto(s)
Encephalitozoon cuniculi , Encefalitozoonosis , Microsporidios , Masculino , Humanos , Femenino , Microsporidios/genética , Encephalitozoon cuniculi/genética , República Checa/epidemiología , Encefalitozoonosis/epidemiología , Inflamación
5.
EMBO J ; 39(1): e99165, 2020 01 02.
Artículo en Inglés | MEDLINE | ID: mdl-31571238

RESUMEN

The success of Yamanaka factor reprogramming of somatic cells into induced pluripotent stem cells suggests that some factor(s) must remodel the nuclei from a condensed state to a relaxed state. How factor-dependent chromatin opening occurs remains unclear. Using FRAP and ATAC-seq, we found that Oct4 acts as a pioneer factor that loosens heterochromatin and facilitates the binding of Klf4 and the expression of epithelial genes in early reprogramming, leading to enhanced mesenchymal-to-epithelial transition. A mutation in the Oct4 linker, L80A, which shows impaired interaction with the BAF complex component Brg1, is inactive in heterochromatin loosening. Oct4-L80A also blocks the binding of Klf4 and retards MET. Finally, vitamin C or Gadd45a could rescue the reprogramming deficiency of Oct4-L80A by enhancing chromatin opening and Klf4 binding. These studies reveal a cooperation between Oct4 and Klf4 at the chromatin level that facilitates MET at the cellular level and shed light into the research of multiple factors in cell fate determination.


Asunto(s)
Reprogramación Celular , Células Epiteliales/metabolismo , Heterocromatina/metabolismo , Histonas/metabolismo , Células Madre Pluripotentes Inducidas/citología , Factores de Transcripción de Tipo Kruppel/metabolismo , Factor 3 de Transcripción de Unión a Octámeros/metabolismo , Animales , Antioxidantes/farmacología , Ácido Ascórbico/farmacología , Proteínas de Ciclo Celular/genética , Proteínas de Ciclo Celular/metabolismo , Diferenciación Celular , Células Cultivadas , ADN Helicasas/genética , ADN Helicasas/metabolismo , Células Epiteliales/citología , Transición Epitelial-Mesenquimal , Fibroblastos/citología , Fibroblastos/metabolismo , Heterocromatina/genética , Histonas/genética , Humanos , Células Madre Pluripotentes Inducidas/metabolismo , Factor 4 Similar a Kruppel , Factores de Transcripción de Tipo Kruppel/genética , Ratones , Proteínas Nucleares/genética , Proteínas Nucleares/metabolismo , Factor 3 de Transcripción de Unión a Octámeros/genética , Factores de Transcripción/genética , Factores de Transcripción/metabolismo
6.
Small ; 20(7): e2303506, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37806770

RESUMEN

Aseptic loosening of prostheses is a highly researched topic, and wear particle-induced macrophage polarization is a significant cause of peri-prosthetic osteolysis. Exosomes derived from bone marrow mesenchymal stem cells (BMSCs-Exos) promote M2 polarization and inhibit M1 polarization of macrophages. However, clinical application problems such as easy clearance and lack of targeting exist. Exosomes derived from M2 macrophages (M2-Exos) have good biocompatibility, immune escape ability, and natural inflammatory targeting ability. M2-Exos and BMSCs-Exos fused exosomes (M2-BMSCs-Exos) are constructed, which targeted the osteolysis site and exerted the therapeutic effect of both exosomes. M2-BMSCs-Exos achieved targeted osteolysis after intravenous administration inhibiting M1 polarization and promoting M2 polarization to a greater extent at the targeted site, ultimately playing a key role in the prevention and treatment of aseptic loosening of prostheses. In conclusion, M2-BMSCs-Exos can be used as a precise and reliable molecular drug for peri-prosthetic osteolysis. Fused exosomes M2-BMSCs-Exos  were originally proposed and successfully prepared, and exosome fusion technology provides a new theoretical basis and solution for the clinical application of therapeutic exosomes.


Asunto(s)
Exosomas , Células Madre Mesenquimatosas , Osteólisis , Humanos , Administración Intravenosa , Macrófagos
7.
Rheumatology (Oxford) ; 63(4): 970-976, 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-37402609

RESUMEN

OBJECTIVE: To investigate whether biological DMARDs affect the risk of aseptic loosening after total hip/knee arthroplasty (THA/TKA) in patients with RA. METHODS: We retrospectively identified all patients suffering from RA who underwent THA/TKA at our academic centre between 2002 and 2015 and linked them with an existing prospective observational RA database at our institution. The risk of aseptic loosening was estimated using radiological signs of component loosening (RCL). A time-dependent Cox regression analysis was used to compare the risk of implant loosening between patients treated with traditional DMARDS and biological DMARDs, or alternately both over time. RESULTS: A total of 155 consecutive total joint arthroplasties (TJAs) (103 TKA vs 52 THA) was retrospectively included in the study. Mean age at implantation was 59 ± 13 years. Mean follow-up time was 69 ± 43 months. Overall, 48 (31%) TJAs showed signs of RCL, with 28 (27.2%) RCLs occurring after TKA compared with 20 after THA (38.5%). A significant difference regarding the incidence of RCL between the traditional DMARDs group (39 cases of RCL, 35%) and the biological DMARDs group (nine cases of RCL, 21%) (P = 0.026) was observed using the log-rank test. This was also true when using a time-dependent Cox regression with therapy as well as arthroplasty location (hip vs knee) as variables (P = 0.0447). CONCLUSION: Biological DMARDs may reduce the incidence of aseptic loosening after TJA in patients with RA compared with traditional DMARDs. This effect seems to be more pronounced after TKA than THA.


Asunto(s)
Antirreumáticos , Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Humanos , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Artroplastia de Reemplazo de Cadera/efectos adversos , Análisis de Regresión , Antirreumáticos/uso terapéutico , Reoperación , Falla de Prótesis
8.
Osteoporos Int ; 35(3): 543-549, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37921994

RESUMEN

Preoperative bone density assessment is necessary to predict screw loosening. The forearm BMD is a useful predictor of BMD-related complications after lumbar operation. Our results show that the forearm BMD is as effective a predictor of screw loosening as the lumbar average HU value. Measurement of the forearm BMD may be a useful adjunct in predicting screw loosening following lumbar fusion. PURPOSE: To determine the relationship between forearm bone mineral density (BMD) and the risk of pedicle screw loosening in patients with lumbar spondylolisthesis. METHODS: We retrospectively evaluated 270 patients who underwent posterior lumbar interbody fusion for lumbar spondylolisthesis. The patients were divided into two groups on the basis of the with or without loose screws: the loosening group and the non-loosening group. The patient's gender, age, BMI, smoking and diabetes histories, and the operative segment were recorded as the basic information. The Hounsfield unit (HU) value for the BMD of the L1-4 lumbar was measured using computed tomography. The patient's distal one-third of the length of the radius and ulna of the non-dominant forearm was chosen as the site for dual-energy X-ray (DXA) bone density testing. RESULTS: The rate of screw loosening was 13% at a minimum 12 months follow-up. Average forearm BMD (0.461 ± 0.1 vs 0.577 ± 0.1, p < 0.001) and mean HU value (L1-4) (121.1 ± 27.3 vs 155.6 ± 32.2, p < 0.001) were lower in the screw loosening group than those in the non-loosening group. In multivariate logistic regression analysis, the forearm BMD (OR 0.840; 95%CI 0.797-0.886) and HU value (L1-4) (OR 0.952; 95%CI 0.935-0.969) were independent risk factor for screw loosening. The area under the curve (AUC) for the forearm BMD and HU value for prediction of pedicle screw loosening was 0.802 and 0.811. The forearm BMD cut-off for predicting pedicle screw loosening was 0.543 (sensitivity, 0.800; specificity, 0.864). CONCLUSIONS: The forearm BMD was an independent risk factor for loosening of the lumbar pedicle screws. The forearm BMD was a valid predictor of pedicle screw loosening in patients undergoing lumbar fusion, as was the CT HU value.


Asunto(s)
Tornillos Pediculares , Fusión Vertebral , Espondilolistesis , Humanos , Densidad Ósea , Espondilolistesis/diagnóstico por imagen , Espondilolistesis/cirugía , Antebrazo , Estudios Retrospectivos , Tornillos Pediculares/efectos adversos , Vértebras Lumbares/cirugía , Fusión Vertebral/efectos adversos , Fusión Vertebral/métodos
9.
J Surg Oncol ; 129(5): 995-999, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38221660

RESUMEN

BACKGROUND AND OBJECTIVES: With continued advances in treatment options, patients with endoprosthetic reconstruction are living longer and consequently relying upon their devices for a longer duration. Major causes of endoprosthesis failure include aseptic loosening and mechanical failure. In the setting of tumor resection, loss of bone stock and use of radiation therapy increase the risk for these complications. As such, considerations of remaining native bone and stem length and diameter may be increasingly important. We asked the following questions: (1) What was the overall rate of endoprosthesis failure at a minimum of 5-year follow-up? (2) Does resection length increase implant failure rates? (3) Does implant size and its ratio to cortical width of bone alter implant failure rates? METHODS: We retrospectively analyzed patient outcomes at a single institution between the years of 1999-2022 who underwent cemented endoprosthetic reconstruction at the hip or knee and identified 150 patients. Of these 150, 55 had a follow-up of greater than 5 years and were used for analysis. Radiographs of these patients at time of surgery were assessed and measured for resection length, bone diameter, stem diameter, and remaining bone length. Resection percentage, and stem to bone diameter ratios were then calculated and their relationship to endoprosthesis failure were analyzed. RESULTS: Patients in this cohort had a mean age of 55.8, and mean follow-up of 59.96 months. There were 78 distal femoral replacements (52%), 16 proximal femoral replacements (10.7%), and 56 proximal tibial replacements (37.3%). There were five patients who experienced aseptic loosening and six patients who experienced mechanical failure. Patients with implant failure had a smaller mean stem to bone diameter (36% vs. 44%; p = 0.002). A stem to bone diameter of 40% appeared to be a breaking point between success and failure in this series, with 90% of patients with implant failure having a stem: bone ratio less than 40%. Stem to bone ratio less than 40% increased risk for failure versus stems that were at least 40% the diameter of bone (6/19 [31.6%] vs. 0/36 [0%]; odds ratio 0.68; p < 0.001). Resection length did not appear to have an impact on the rates of aseptic loosening and mechanical failure in this series. CONCLUSIONS: Data from this series suggests a benefit to using stems with a larger diameter when implanting cemented endoprostheses at the hip or knee. Stems which were less than 40% the diameter of bone were substantially more likely to undergo implant failure.


Asunto(s)
Fémur , Falla de Prótesis , Humanos , Persona de Mediana Edad , Diseño de Prótesis , Estudios Retrospectivos , Fémur/diagnóstico por imagen , Fémur/cirugía , Tibia/diagnóstico por imagen , Tibia/cirugía , Reoperación , Resultado del Tratamiento
10.
Eur Spine J ; 33(1): 289-297, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37981599

RESUMEN

STUDY DESIGN: Retrospective cohort. OBJECTIVE: The purpose of this study is to assess the potential of utilizing the MRI-based vertebral bone quality (VBQ) score as a predictive tool for pedicle screw loosening (PSL) in patients who have undergone pedicle screw fixation and to identify risk factors associated with VBQ scores. METHODS: One hundred and sixteen patients who had undergone pedicle screw fixation between December 2019 and January 2021 and had more than a year of follow-up were divided into two groups of PSL and non-PSL. The radiological and clinical parameters investigated were age, gender, body mass index, the VBQ score, length of fusion and the DXA T-score. RESULTS: Of the 116 patients included in the study, 22 patients developed pedicle screw loosening after surgery (18.97%). VBQ score of PSL group was higher than the non-PSL group (3.61 ± 0.63 vs. 2. 86 ± 0.43, p < 0.001). According to logistic regression, PSL was independently linked with a higher VBQ score (OR = 3.555, 95% confidence interval [1.620-7.802], p < 0.005). The AUC of predicting screw loosening was 0.774 (p < 0.001) for VBQ score, and the best threshold was 3.055 (sensitivity, 81.8%; specificity, 71.3%). High VBQ score was associated with age (r (114) = 0.29, p = 0.002), while it was not negatively correlated with T-scores of each part. CONCLUSION: VBQ score is an independent predictor of pedicle screw loosening, with higher scores indicating a greater risk. Our results showed that older patients and women had higher VBQ scores.


Asunto(s)
Tornillos Pediculares , Fusión Vertebral , Humanos , Femenino , Tornillos Pediculares/efectos adversos , Estudios Retrospectivos , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Imagen por Resonancia Magnética , Radiografía , Fusión Vertebral/efectos adversos , Fusión Vertebral/métodos
11.
Eur Spine J ; 33(7): 2751-2762, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38619634

RESUMEN

INTRODUCTION: Despite modern fixation techniques, spinopelvic fixation failure (SPFF) after adult spinal deformity (ASD) surgery ranges from 4.5 to 38.0%, with approximately 50% requiring reoperation. Compared to other well-studied complications after ASD surgery, less is known about the incidence and predictors of SPFF. AIMS/OBJECTIVES: Given the high rates of SPFF and reoperation needed to treat it, the purpose of this systematic review and meta-analysis was to report the incidence and failure mechanisms of SPF after ASD surgery. MATERIALS/METHODS: The literature search was executed across four databases: Medline via PubMed and Ovid, SPORTDiscus via EBSCO, Cochrane Library via Wiley, and Scopus. Study inclusion criteria were patients undergoing ASD surgery with spinopelvic instrumentation, report rates of SPFF and type of failure mechanism, patients over 18 years of age, minimum 1-year follow-up, and cohort or case-control studies. From each study, we collected general demographic information (age, gender, and body mass index), primary/revision, type of ASD, and mode of failure (screw loosening, rod breakage, pseudarthrosis, screw failure, SI joint pain, screw protrusion, set plug dislodgment, and sacral fracture) and recorded the overall rate of SPF as well as failure rate for each type. For the assessment of failure rate, we required a minimum of 12 months follow-up with radiographic assessment. RESULTS: Of 206 studies queried, 14 met inclusion criteria comprising 3570 ASD patients who underwent ASD surgery with pelvic instrumentation (mean age 65.5 ± 3.6 years). The mean SPFF rate was 22.1% (range 3-41%). Stratification for type of failure resulted in a mean SPFF rate of 23.3% for the pseudarthrosis group; 16.5% for the rod fracture group; 13.5% for the iliac screw loosening group; 7.3% for the SIJ pain group; 6.1% for the iliac screw group; 3.6% for the set plug dislodgement group; 1.1% for the sacral fracture group; and 1% for the iliac screw prominence group. CONCLUSION: The aggregate rate of SPFF after ASD surgery is 22.1%. The most common mechanisms of failure were pseudarthrosis, rod fracture, and iliac screw loosening. Studies of SPFF remain heterogeneous, and a consistent definition of what constitutes SPFF is needed. This study may enable surgeons to provide patient specific constructs with pelvic fixation constructs to minimize this risk of failure.


Asunto(s)
Fusión Vertebral , Humanos , Fusión Vertebral/métodos , Fusión Vertebral/efectos adversos , Fusión Vertebral/instrumentación , Curvaturas de la Columna Vertebral/cirugía , Curvaturas de la Columna Vertebral/diagnóstico por imagen , Insuficiencia del Tratamiento , Adulto , Reoperación/estadística & datos numéricos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología
12.
BMC Musculoskelet Disord ; 25(1): 277, 2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38600536

RESUMEN

INTRODUCTION: The number of primary and revision Total Knee Arthroplasty (TKA) cases are expected to increase in future. There are various advantages and disadvantage to employing either of the two main types of stem fixation methods - cemented or hybrid technique. This review aimed to study the most optimal fixation method for revision TKAs by comparing radiological outcomes and re-revision rates. METHODS: A systematic review and meta-analysis was performed using PubMed and Cochrane Library from 2010 to identify studies explicitly comparing outcomes between cemented against hybrid fixation revision TKA techniques, with a minimum follow up of at least 24 months. A total of 8 studies was included in this review. Egger's test and visual inspection of the funnel plot did not reveal publication bias. RESULTS: There was no statistically significant difference in radiological failure and loosening (OR 0.79, CI 0.37-1.66, I2 = 29%, p = 0.22), all causes of re-revision (OR 1.03, CI 0.73-1.44, I2 = 0%, p = 0.56) and aseptic revision (OR 0.74, CI 0.27-2.02, I2 = 0%, p = 0.41) between cemented and hybrid techniques. Functional and pain outcomes compared between the two fixation techniques were largely similar across the studies included in this meta-analysis. CONCLUSION: Despite a trend favouring hybrid stems in revision TKA, current evidence revealed that radiological outcomes and re-revision rates are largely similar between cemented and hybrid fixation techniques.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Cementos para Huesos/uso terapéutico , Examen Físico , Diseño de Prótesis , Falla de Prótesis , Reoperación/métodos , Resultado del Tratamiento
13.
BMC Musculoskelet Disord ; 25(1): 516, 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38970034

RESUMEN

BACKGROUND: Sacral screw loosening is a typical complication after internal fixation surgery through the vertebral arch system. Bicortical fixation can successfully prevent screw loosening, and how improving the rate of bicortical fixation is a challenging clinical investigation. OBJECTIVE: To investigate the feasibility of improving the double corticality of sacral screws and the optimal fixation depth to achieve double cortical fixation by combining the torque measurement method with bare hands. METHODS: Ninety-seven cases of posterior lumbar internal fixation with pedicle root system were included in this study. Based on the tactile feedback of the surgeon indicating the expected penetration of the screw into the contralateral cortex of the sacrum, the screws were further rotated by 180°, 360°, or 720°, categorized into the bicortical 180° group, bicortical 360° group, and bicortical 720° group, respectively. Intraoperatively, the torque during screw insertion was recorded. Postoperatively, the rate of double-cortex engagement was evaluated at 7 days, and screw loosening was assessed at 1 year follow-up. RESULTS: The bicortical rates of the 180° group, 360° group, and 720° group were 66.13%, 91.18% and 93.75%, respectively. There were statistically significant differences between the 180° group and both the 360° and 720° groups (P < 0.05). However, there was no statistically significant difference between the 360° group and the 720° group (P > 0.05).The rates of loosening of sacral screws in the 180° group, 360° group, and 720° group were 20.97%, 7.35% and 7.81%, respectively. There were statistically significant differences between the 180° group and both the 360° and 720° groups (P < 0.05). However, there was no statistically significant difference between the 360° group and the 720° group (P > 0.05). The bicortical 360° group achieved a relatively satisfactory rate of dual cortical purchase while maintaining a lower rate of screw loosening. CONCLUSION: Manual insertion of sacral screws with the assistance of a torque measurement device can achieve a relatively satisfactory dual cortical purchase rate while reducing patient hospitalization costs.


Asunto(s)
Tornillos Óseos , Vértebras Lumbares , Sacro , Fusión Vertebral , Torque , Humanos , Masculino , Femenino , Sacro/cirugía , Sacro/diagnóstico por imagen , Persona de Mediana Edad , Anciano , Fusión Vertebral/instrumentación , Fusión Vertebral/métodos , Fusión Vertebral/efectos adversos , Vértebras Lumbares/cirugía , Adulto , Estudios de Factibilidad , Resultado del Tratamiento , Estudios de Seguimiento
14.
BMC Musculoskelet Disord ; 25(1): 418, 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38807200

RESUMEN

BACKGROUND: It was reported the paraspinal muscle played an important role in spinal stability. The preoperative paraspinal muscle was related to S1 screw loosening. But the relationship between preoperative and postoperative change of psoas major muscle (PS) and S1 pedicle screw loosening in degenerative lumbar spinal stenosis (DLSS) patients has not been reported. This study investigated the effects of preoperative and follow-up variations in the psoas major muscle (PS) on the first sacral vertebra (S1) screw loosening in patients with DLSS. METHODS: 212 patients with DLSS who underwent lumbar surgery were included. The patients were divided into the S1 screw loosening group and the S1 screw non-loosening group. Muscle parameters were measured preoperatively and at last follow-up magnetic resonance imaging. A logistic regression analysis was performed to investigate the risk factors for S1 screw loosening. RESULTS: The S1 screw loosening rate was 36.32% (77/212). The relative total cross-sectional areas and relative functional cross-sectional areas (rfCSAs) of the PS at L2-S1 were significantly higher after surgery. The increased rfCSA values of the PS at L3-S1 in the S1 screw non-loosening group were significantly higher than those in the S1 screw loosening group. The regression analysis showed male, lower CT value of L1 and longer segment fusion were independent risk factors for S1 screw loosening, and postoperative hypertrophy of the PS was a protective factor for S1 screw loosening. CONCLUSIONS: Compared to the preoperative muscle, the PS size increased and fatty infiltration decreased after surgery from L2-3 to L5-S1 in patients with DLSS after short-segment lumbar fusion surgery. Postoperative hypertrophy of the PS might be considered as a protective factor for S1 screw loosening. MRI morphometric parameters and postoperative selected exercise of PS for DLSS patients after posterior lumbar fusion surgery might contribute to improvement of surgical outcome.


Asunto(s)
Vértebras Lumbares , Tornillos Pediculares , Músculos Psoas , Fusión Vertebral , Estenosis Espinal , Humanos , Masculino , Estenosis Espinal/cirugía , Estenosis Espinal/diagnóstico por imagen , Femenino , Vértebras Lumbares/cirugía , Vértebras Lumbares/diagnóstico por imagen , Anciano , Músculos Psoas/diagnóstico por imagen , Persona de Mediana Edad , Estudios de Seguimiento , Fusión Vertebral/instrumentación , Fusión Vertebral/efectos adversos , Imagen por Resonancia Magnética , Sacro/diagnóstico por imagen , Sacro/cirugía , Estudios Retrospectivos , Factores de Riesgo , Anciano de 80 o más Años , Periodo Preoperatorio
15.
Acta Microbiol Immunol Hung ; 71(2): 172-181, 2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38619882

RESUMEN

Prosthetic joint infection (PJI) and aseptic loosening (AL) are common complications of total joint arthroplasty. An accumulation of evidence indicates the presence of microbial communities on prosthetic implants, but the overall microbial profile is unclear. In this study, we aimed to investigate the differences in the microbial composition of prosthetic implants obtained from PJI and AL patients using the 16S rRNA sequencing method. Patients who underwent revision hip, knee, or shoulder arthroplasty caused by PJI (n = 20) or AL (n = 10) were enrolled in the study. 16S rRNA sequencing targeting the V3-V4 region was performed on the microbial specimens collected from synovial fluid, periprosthetic deep-tissue, and biofilm during the revision surgery. The sequenced raw data were analysed for microbial composition and ecological and differential abundance analyses using bioinformatics tools. The AL group had relatively balanced and higher diversity, with Staphylococcus, Streptococcus, and Veillonella being prominent. In the PJI group, Staphylococcus and Pseudomonas were predominant, especially in deep-tissue samples and biofilm samples, respectively. The differential abundance analysis identified 15 and 2 distinctive taxa in the AL and PJI groups, respectively. Our findings provided preliminary insights supporting the existence of periprosthetic microbiota in orthopedic implants and explaining the differences in microbial composition between the AL and PJI groups.


Asunto(s)
Bacterias , Microbiota , Infecciones Relacionadas con Prótesis , ARN Ribosómico 16S , Humanos , Infecciones Relacionadas con Prótesis/microbiología , ARN Ribosómico 16S/genética , Femenino , Masculino , Anciano , Persona de Mediana Edad , Bacterias/clasificación , Bacterias/genética , Bacterias/aislamiento & purificación , Biopelículas/crecimiento & desarrollo , Falla de Prótesis , Prótesis Articulares/microbiología , Prótesis Articulares/efectos adversos , Anciano de 80 o más Años
16.
Artículo en Inglés | MEDLINE | ID: mdl-39126268

RESUMEN

PURPOSE: Establishing the diagnosis of loosening in total or unicondylar knee arthroplasty remains a challenge with different clinical and radiological signs evaluated in study designs with high risk of bias, where few or incomplete criteria are formulated for establishing the diagnosis of implant loosening. This study aimed at evaluating the variability between different clinical and radiological criteria and establish a consensus regarding clinical and radiological criteria for the diagnosis of knee arthroplasty loosening. METHODS: Highly specialized knee surgeons focusing on revision arthroplasty were invited to take part in an international panel for a Delphi consensus study. In the first round, the participants were asked to state their most important clinical and radiological criteria for implant loosening. In a second round, the panel's agreement with the collected criteria was rated on a 5-point Likert scale (1-5). High variability was defined by receiving at least one score each indicating complete disagreement and complete agreement. Consensus was established when over 70% of participants rated a criterion as 'fully agree' (5) or 'mostly agree' (4). RESULTS: High variability was observed in 56% of clinical criteria and 38% of radiological criteria. A consensus was reached on one clinical (weight-bearing pain [82%]) and four radiological criteria, that is, implant migration, progressive radiolucencies, subsidence and radiolucencies >2 mm on X-ray or computed tomography (CT) (84%-100%). CONCLUSION: Amongst specialized knee revision surgeons, there is high variability in clinical and radiological criteria that are seen as important contributing factors to diagnosis of knee implant loosening. A consensus was reached on weight-bearing pain as clinical criterion and on implant migration, progressive radiolucencies, subsidence and radiolucencies of more than 2 mm on X-ray or CT as radiological criteria. The variability rates observed, along with the criteria that reached consensus, offer important insights for the standardization of diagnostic protocols. LEVEL OF EVIDENCE: Level V.

17.
Artículo en Inglés | MEDLINE | ID: mdl-38819937

RESUMEN

PURPOSE: Aseptic loosening often requires major, expensive and invasive revision surgery. Current diagnostic modalities merely show indirect signs of loosening. A recent proof of concept study proposed a non-invasive technique for the quantitative and visual assessment of implant movement as a diagnostic aid for tibial component loosening. The primary research question addressed is whether this novel diagnostic modality can safely and effectively aid the diagnosis of aseptic loosening. METHODS: This clinical study included patients suspected of aseptic total knee arthroplasty (TKA) loosening listed for revision surgery and asymptomatic patients. Safety was evaluated using a numerical rating scale (NRS) for discomfort and by registration of adverse events. Feasibility was assessed by recording the duration and ease of the procedure. Intra- and interrater reliability were evaluated. In symptomatic patients, diagnostic accuracy metrics were evaluated with intra-operative assessment as a reference test. RESULTS: In total, 34 symptomatic and 38 asymptomatic knees with a TKA were analysed. The median NRS for discomfort during loading was 6 (interquartile range [IQR]: 3.75-7.00) in symptomatic patients and 2 (IQR: 1.00-3.00) in asymptomatic patients. No adverse events were reported. The majority of users found the use of the loading device easy. The median time spent in the computed tomography room was 9 min (IQR: 8.00-11.00). Excellent to good intra- and interrater reliabilities were achieved. Diagnostic accuracy analysis resulted in a sensitivity of 0.91 (95% confidence interval [CI]: 0.72-0.97) and a specificity of 0.72 (95% CI: 0.43-0.90). CONCLUSIONS: The proposed diagnostic method is safe, feasible, reliable and accurate in aiding the diagnosis of aseptic tibial component loosening. LEVEL OF EVIDENCE: Level II.

18.
Knee Surg Sports Traumatol Arthrosc ; 32(8): 2061-2074, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38769774

RESUMEN

PURPOSE: The purpose of this study was to evaluate and compare the diagnostic accuracy of modalities used to aid the diagnosis of aseptic knee arthroplasty loosening. METHODS: A comparative diagnostic test accuracy systematic review and meta-analysis was conducted following the Cochrane and PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. PubMed, EMBASE and Cochrane databases were searched for original articles evaluating diagnostic modalities up to March 2024. Included studies compared the modality (index test) to the intraoperative finding as reference test. The QUADAS-C (Quality Assessment of Diagnostic Accuracy Studies-Comparative) tool was used to assess the quality of the included studies. The GRADE (Grading of Recommendations, Assessment, Development and Evaluation) approach was used to evaluate the certainty of evidence. Level of evidence was evaluated using the Oxford Levels of Evidence tool. The primary outcome was the summary of diagnostic accuracy metrics for each modality as demonstrated by a summary receiver-operating characteristic (SROC) curve. RESULTS: The search yielded 467 articles. Of these, 14 articles were included. These 14 articles evaluated a total of five different diagnostic modalities: bone scintigraphy (three studies, 146 cases), 18-fluorodeoxyglucose positron emission tomography (two studies, 50 cases), single-photon emission computed tomography combined with computed tomography (SPECT/CT) (seven studies, 371 cases), radionuclide arthrogram (three studies, 196 cases) and magnetic resonance imaging (MRI) (one study, 116 cases). Nine studies exhibited a high risk of bias in patient selection, and all studies showed a high risk of bias related to the reference test. The majority of the included studies were classified as Level III evidence, leading to an overall low level of certainty in the evidence. The most accurate tests, as demonstrated by the SROC analysis, were MRI and SPECT/CT, with sensitivities ranging from 0.00 to 1.00 and 0.33 to 1.00 and specificities between 0.31-1.00 and 0.00-1.00, respectively. CONCLUSIONS: This review and meta-analysis evaluated available diagnostic modalities to aid the diagnosis of knee arthroplasty loosening and based on a low certainty of evidence suggests that MRI and SPECT/CT are currently the most accurate modalities available to aid the diagnosis of aseptic loosening of knee arthroplasty components. LEVEL OF EVIDENCE: Level III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Imagen por Resonancia Magnética , Falla de Prótesis , Humanos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Sensibilidad y Especificidad
19.
Artículo en Inglés | MEDLINE | ID: mdl-39010716

RESUMEN

PURPOSE: There is a lack of a clear, uniform definition for intraoperatively assessed component loosening of a knee arthroplasty component, complicating the interpretation and interchangeability of results of diagnostic studies using an intraoperative observation as the reference test. The purpose of this study was to establish a consensus among specialised knee revision surgeons regarding the definition of intraoperatively determined loosening of total or unicondylar knee arthroplasty components. METHODS: Utilising the Delphi consensus method, an international panel of highly specialised knee revision surgeons was invited to participate in a three-round process. The initiation of the first round involved the exploration of possible criteria for intraoperatively determined loosening with open questions. The second round focused on rating these criteria importance on a five-point Likert scale. For the third round, criteria that reached consensus were summarised in consecutive definitions for intraoperatively determined loosening and proposed to the panel. Consensus was established when over 70% of participants agreed with a definition for intraoperatively determined loosening. RESULTS: The 34 responding panel members described in total 60 different criteria in the first round of which 34 criteria received consensus in the second round. Summarising these criteria resulted in four different definitions as minimal requirements for intraoperatively determined loosening. Eighty-eight percent of the panel members agreed on defining a component as loose if there is visible fluid motion at the interface observed during specific movements or when gently applying direct force. CONCLUSION: This study successfully established a consensus using a Delphi method among knee revision surgeons on the definition of intraoperatively determined component loosening. By agreeing on the visibility of fluid motion as new definition, this study provides a standardised reference for future diagnostic research. This definition will enhance the interpretability and interchangeability of future diagnostic studies evaluating knee arthroplasty component loosening. LEVEL OF EVIDENCE: Level V.

20.
Knee Surg Sports Traumatol Arthrosc ; 32(3): 693-703, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38415963

RESUMEN

PURPOSE: Assessing the risk of tibial baseplate loosening in patients after unrestricted kinematically aligned (unKA) total knee arthroplasty (TKA) using a medially conforming insert is important because baseplates generally are aligned in varus which has been linked to an increased incidence of aseptic loosening following mechanically aligned TKA. Two limits that indicate long-term stability in patients are a change in maximum total point motion between 1 and 2 years (ΔMTPM) < 0.2 mm and anterior tilt at 2 years < 0.8°. The purposes were to determine: (1) the number of patients with ΔMTPM > 0.2 mm, (2) the number of patients with anterior tilt > 0.8° and (3) whether increased varus baseplate and limb alignment were associated with increased migration. METHODS: Thirty-five patients underwent cemented, caliper-verified, unKA TKA using a medially conforming tibial insert with posterior cruciate ligament (PCL) retention. Biplanar radiographs acquired on the day of surgery and at 1.5, 3, 6, 12 and 24 months were processed with model-based radiostereometric analysis (RSA) software to determine migration and the number of patients with migration above the two stability limits. Medial proximal tibial angle (MPTA), hip-knee-ankle angle (HKAA) and posterior slope angle (PSA) were analyzed for an association with migration in six degrees of freedom and in MTPM. RESULTS: Thirty-two of 35 patients were available for analysis at 2 years. One patient exhibited ΔMTPM > 0.2 mm. The same patient exhibited anterior tilt > 0.8°. Varus rotation (p = 0.048, r ≤ 0.34) and medial translation (p = 0.0273, r ≤ 0.29) increased with increased varus baseplate alignment. CONCLUSION: The results indicate low risk of long-term baseplate loosening in patients. Although varus rotation and medial translation increased with increased varus baseplate alignment, the magnitudes of the migrations were minimal and did not increase ΔMTPM and anterior tilt. LEVEL OF EVIDENCE: Level II, therapeutic prospective cohort study.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Análisis Radioestereométrico , Prótesis de la Rodilla/efectos adversos , Fenómenos Biomecánicos , Estudios Prospectivos , Articulación de la Rodilla/cirugía , Tibia/cirugía , Osteoartritis de la Rodilla/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA