RESUMEN
BACKGROUND: Primary hypertension (HTN) in children is on the rise and linked to the childhood obesity epidemic. Recent studies support the role of hyperuricemia in the pathogenesis of HTN. With this study we intend to evaluate the effect of body mass index (BMI) and uric acid levels on daily blood pressure (BP) parameters/phenotypes and target organ damage (TOD). METHODS: A mean ambulatory systolic and/or diastolic BP ≥ 95th percentile or above the adolescent cut points was defined as 'HTN'. Patients were grouped as group 1 normal weight, and group 2 overweight/obese. RESULTS: Of the 140 children (89 male/51 female) with a mean age of 13.9 ± 2.6 years, 21 were overweight and 86 were obese. Mean 24-h systolic BP (SBP) and daytime SBP were higher in group 2 (p = 0.015, p = 0.011). BMI was positively correlated with 24-h SBP (r = 0.272, p = 0.001) and daytime SBP (r = 0.280, p = 0.001). Uric acid level showed a moderate correlation with daytime SBP (r = 0.311, p < 0.01). Logistical regression analysis showed that daytime SBP is independently associated with obesity (OR 7.44, 95%CI 2.7-20.6, p < 0.001) and male sex (OR 4.60, 95%CI 2.0-10.2, p < 0.001), but not uric acid. Left ventricular hypertrophy was more common in non-dippers (p = 0.044). CONCLUSIONS: Male sex and BMI are independently associated risk factors for systolic BP. The association between non-dipping pattern and TOD suggests the widespread use of ambulatory blood pressure monitoring (ABPM) in childhood HT. In this paper, we could not demonstrate an independent association between uric acid and SBP. The effect of uric acid on SBP seems to be regulated by other metabolic factors in addition to uric acid.
RESUMEN
AIMS: The frontal QRS-T (fQRST) angle is associated with worse cardiovascular outcome. The study aimed to assess the effect of reverse dipping pattern on f(QRST) angle in newly diagnosed masked hypertensive (MH) patients. MATERIALS AND METHODS: Newly diagnosed 244 consecutive MH patients were included. According to dipping pattern, patients were grouped into three: dipper (n = 114), non-dipper (n = 106), and reverse dipper (n = 24) patterns. The f(QRST) angle, QT and corrected QT interval, and QT dispersion were measured from the 12-lead surface electrocardiogram and compared between groups. RESULTS: Of all, 51.2% (n = 125) were male. No gender difference was observed. Reverse dipper MH group had a significantly higher f(QRST) angle than the non-dipper and dipper MH groups (77.9 ± 8.6 vs. 32.4 ± 18.8 and 26.0 ± 18.5, respectively, p < .001). The cutoff value for f(QRST) angle of 51 predicts reverse dipping pattern (AUC: 0.84; 95% CI: 0.77-0.90; p < .001), with a sensitivity of 83% and a specificity of 78%. CONCLUSION: This study revealed that f(QRST) angle is gradually increased starting from the dipper, non-dipper to reverse dipper masked hypertensives. The f(QRST) angle appears as an easy marker for the detection and risk stratification of hypertensive patients.
Asunto(s)
Ritmo Circadiano , Hipertensión , Humanos , Masculino , Femenino , Presión Sanguínea , Hipertensión/diagnóstico , Corazón , Electrocardiografía , Monitoreo Ambulatorio de la Presión ArterialRESUMEN
AIMS: Epicardial adipose tissue has been reported to be associated with the development of cardiometabolic disease. Whether this is true for hypertension and non-dipper blood pressure remains controversial. Here, we conducted a systemic review and meta-analysis to evaluate the association between EAT and blood pressure. DATA SYNTHESIS: Pubmed, Embase, and Web of Science were searched for relevant papers. Studies reported on the difference of EAT thickness between hypertensive and normotensive patients, or those recorded odds ratio (OR) between EAT and hypertension were included. The standard mean difference (SMD) and ORs were extracted and pooled using a random-effects model respectively. We further assessed the effect of EAT on circadian rhythm of blood pressure by combining multiple-adjusted ORs for non-dipper blood pressure. Seven studies with an overall sample of 1089 patients reported the mean difference of EAT thickness between hypertensive and normotensive patients, and the hypertensive patients had higher EAT (SMD = 1.07; 95% CI: 0.66-1.48; I2 = 89.2%) compared with controls. However, the pooled association between EAT and hypertension from two studies was not significant (OR = 1.65, 95%CI 0.62-4.68; I2 = 87.5%). The summary risk effect of EAT on non-dipper blood pressure from six studies comprising1208 patients showed that each 1 mm increment of EAT was associated with a 2.55-fold risk of non-dipper blood pressure. CONCLUSION: Hypertensive patients tend to present higher EAT thickness near the right ventricular wall and increased EAT thickness might be associated with high risk of non-dipper blood pressure. Future researches are warranted to determine the causal link between EAT and hypertension and the underlying mechanism.
Asunto(s)
Tejido Adiposo/fisiopatología , Adiposidad , Presión Sanguínea , Hipertensión/fisiopatología , Tejido Adiposo/diagnóstico por imagen , Femenino , Humanos , Hipertensión/diagnóstico , Masculino , Pericardio , Pronóstico , Medición de Riesgo , Factores de RiesgoRESUMEN
BACKGROUND: It is known that non-dipper pattern (NDP) is associated with adverse outcomes in hypertensive patients. However, there is insufficient data on the outcome of NDP in normotensive individuals. Using myocardial work (MW) analysis, as a new echocardiographic examination method, this study aimed to determine the early myocardial effects of NDP in normotensive individuals. METHODS: This study included 70 normotensive individuals who were followed by ambulatory blood pressure monitoring (ABPM). The subjects were divided into two groups according to dipper pattern (DP) and NDP. Conventional, strain, and MW findings were compared between the groups by making echocardiographic evaluations. RESULTS: The demographic characteristics, laboratory parameters, and measurements of cardiac chambers, and left ventricular (LV) walls were similar between the groups. There was no statistical difference between the groups in terms of LV 3-2-4 chambers strains and global longitudinal strain (GLS) values. LVMW parameters, global work index (GWI), and global constrictive work (GCW) were not statistically different between groups (2012 ± 127, 2069 ± 137, p = 0.16; 2327 ± 173, 2418 ± 296, p = 0.18, respectively). However, global waste work (GWW) and global work efficiency (GWE) parameters were different between the groups (144 ± 63.9, 104 ± 24.8, p < 0.001; 93.2 ± 3.17, 95.4 ± 1.28, p < 0.001, respectively). In regression analysis, GWW was independently associated with NDP. GWW model showed better results with higher likelihood chi-square and R2 values than GLS model in discriminating the predictable capability for NDP status. CONCLUSION: The results of MW analysis in this study showed that GWW values were higher and the GWE values were lower in normotensive individuals with NDP.
Asunto(s)
Monitoreo Ambulatorio de la Presión Arterial , Hipertensión , Presión Sanguínea , Ecocardiografía , Humanos , Volumen Sistólico , Función Ventricular IzquierdaRESUMEN
OBJECTIVE: There is frequently a relationship between nocturnal hypertension and non-dipping pattern and endothelial dysfunction. Studies conducted previously have indicated that adrenomedullin (AM) (a potent, long-lasting, vasodilatory peptide) is capable of regulating endothelial cell function. The aim of the current research is to investigate the association between absolute night-time blood pressure (BP) and circadian BP pat-tern with serum AM and high-sensitivity C-reactive protein (hsCRP) levels in cases in whom untreated arterial hypertension has been newly diagnosed. METHODS: Ambulatory BP monitoring was performed in 100 individuals with hypertension (50 dippers,50 non-dippers) and 50 healthy controls for 24 hours. Measurement and recording of AM and hsCRP serum levels were performed. RESULTS: A strong correlation between night-time BP levels and AM and hsCRP levels was determined(p<0.001). On the contrary, higher AM levels were determined in the non-dipper group compared to the dipper and normotensive groups (non-dipper group, 258±27 pg/mL; dipper group, 199±30 pg/mL; normotensive group, 150±11 pg/mL; p<0.001). The non-dipper group exhibited significantly higher hsCRP levels in comparison with the remaining two groups (p=0.017). An independent association was determined between AM (p=0.014) and hsCRP (p=0.032) and a non-dipping pattern in a multivariate logistic regression analysis. CONCLUSIONS: The nocturnal hypertensive and non-dipper groups exhibited increased AM levels. An independent association was identified between AM and hsCRP and a non-dipping pattern. It is implied that increased AM levels in individuals with non-dipper hypertension may be related to a longer exposure time to high BP. The mentioned findings indicate a potential future part of AM in identifying patients with hypertension that are at higher risk of target organ damage (Tab. 3, Fig. 4, Ref. 41).
Asunto(s)
Adrenomedulina/sangre , Ritmo Circadiano , Hipertensión Esencial/diagnóstico , Presión Sanguínea , Monitoreo Ambulatorio de la Presión Arterial , Proteína C-Reactiva/análisis , Estudios de Casos y Controles , HumanosRESUMEN
OBJECTIVE: We aimed to investigate whether a simple and easily calculated parameter such as monocyte/ HDL ratio (MHR) may be used in predicting non-dipper (NDHT)-dipper HT (DHT) end organ damage. METHODS: 70 NDHT and 73 DHT patient groups were included in the study according to ambulatory blood pressure screening results. Basic laboratory parameters and spot urine samples were evaluated. Transthoracic echocardiography and ophthalmological examination were performed for end-organ damages. RESULTS: The MHR among the groups was higher in the NDHT group; which was statistically significant (p≤0.001). In the NDHT group, albumin, creatinine, protein values, protein/creatinine ratio in the spot urine were significantly higher than in the DHT group (p≤0.05). Left ventricular hypertrophy (LVH) and retinopathy were also more frequently observed in the NDHT group (p≤0.001 and p=0.001, respectively). MHR in patients with LVH and retinopathy was significantly higher than in those without these complications (p=0.001). CONCLUSION: Easy to use, non-invasive and simple calculation, MHR can be used to predict end organ damage in hypertensive cases, and can be also used to distinguish between DHT/NDHT groups. This data supports the role of inflammation (Tab. 7, Ref. 14).
Asunto(s)
Monitoreo Ambulatorio de la Presión Arterial , HDL-Colesterol , Hipertensión , Hipertrofia Ventricular Izquierda , Monocitos , Presión Sanguínea , HDL-Colesterol/sangre , Ecocardiografía , Humanos , Hipertensión/diagnósticoRESUMEN
BACKGROUND: Endothelial dysfunction is one of the main pathological processes of hypertension. The association of serum pentraxin-3 (PTX3) levels and endothelial dysfunction becomes a more interesting scientific research issue due to high potential of PTX3 as a diagnostic and prognostic biomarker. We aimed to investigate the relationship between serum PTX3 levels and flow-mediated dilation results in patients with dipper and non-dipper hypertension. METHODS: This study included 90 hypertensive patients were divided into two groups based on 24 hours ambulatory blood pressure monitoring (ABPM): 38 patients with a dipper pattern and 52 patients with non-dipper pattern. Noninvasive evaluation of the endothelial functions was performed using flow-mediated dilation (FMD) method. RESULTS: Serum pentraxin-3 levels were higher in patients with non-dipper HT compared to dipper hypertension (P = 0.028). In addition, we found negative correlation between serum PTX3 and FMD basal/FMD hyperemia ratio (r = -0.297, P = 0.05 for FMD basal/FMD hyperemia ratio, respectively). CONCLUSIONS: Serum PTX3 levels are closely related with the measures of indirect noninvasive evaluation methods (FMD) in both DH and NDH patients.
Asunto(s)
Proteína C-Reactiva/análisis , Hipertensión/sangre , Hipertensión/epidemiología , Componente Amiloide P Sérico/análisis , Adulto , Anciano , Biomarcadores/sangre , Monitoreo Ambulatorio de la Presión Arterial , Estudios Transversales , Humanos , Hipertensión/clasificación , Masculino , Persona de Mediana Edad , Resistencia Vascular , VasodilataciónRESUMEN
BACKGROUNDS: Charlson Comorbidity index (CCI) is a scoring system to predict prognosis and mortality. It exhibits better utility when combined with age, age-adjusted Charlson Comorbidity Index (ACCI). The aim of this study was to evaluate the relationship between ACCI and diurnal variation of blood pressure parameters in hypertensive patients and normotensive patients. METHODS: We enrolled 236 patients. All patients underwent a 24-h ambulatory blood pressure monitoring (ABPM) for evaluation of dipper or non-dipper pattern. We searched the correlation between ACCI and dipper or non-dipper pattern and other ABPM parameters. To further investigate the role of these parameters in predicting survival, a multivariate analysis using the Cox proportional hazard model was performed. RESULTS: 167 patients were in the hypertensive group (87 patients in non-dipper status) and 69 patients were in the normotensive group (41 patients in non-dipper status) of all study patients. We found a significant difference and negative correlation between AACI and 24-h diastolic blood pressure (DBP), awake DBP, awake mean blood pressure (MBP) and 24-h MBP and awake systolic blood pressure(SBP). Night decrease ratio of blood pressure had also a negative correlation with ACCI (p = 0.003, r = -0.233). However, we found a relationship with non-dipper pattern and ACCI in the hypertensive patients (p = 0.050). In multivariate Cox analysis sleep MBP was found related to mortality like ACCI (p = 0.023, HR = 1.086, %95 CI 1.012-1.165) Conclusion: ACCI was statistically significantly higher in non-dipper hypertensive patients than dipper hypertensive patients while ACCI had a negative correlation with blood pressure. Sleep MBP may predict mortality.
Asunto(s)
Presión Sanguínea , Ritmo Circadiano/fisiología , Indicadores de Salud , Hipertensión/fisiopatología , Sueño/fisiología , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Monitoreo Ambulatorio de la Presión Arterial , Comorbilidad , Diástole , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Modelos de Riesgos Proporcionales , Sístole , Adulto JovenRESUMEN
OBJECTIVE: Non-dipper hypertension (HT) confers greater risk compared with dipper HT. Growth differentiation factor 15 (GDF-15) recently emerged as a novel and independent marker of cardiovascular disease, both in diagnostic and prognostic scopes. Our aim was to evaluate the relationship of circadian blood pressure (BP) pattern with serum GDF-15 level in newly diagnosed HT patients without left ventricular hypertrophy. SUBJECTS AND METHODS: Newly diagnosed non-dipper (n = 66) and dipper (n = 60) HT patients were selected according to 24-h ambulatory BP monitoring (ABPM). The controls comprised healthy normotensive subjects (n = 31). Data was collected through physical examination, laboratory analysis, ABPM, and echocardiography. GDF-15 was measured using ELISA. RESULTS: Greater GDF-15 level was found in the non-dippers compared with the dippers and the controls (557.53 ± 91.7, 513.79 ± 62.86, and 494.44 ± 79.30 ng/L, respectively, p < 0.001). In bivariate linear correlation analysis, GDF-15 correlated positively with glomerular filtration rate (r = 0.180, p =0.030), total cholesterol (r = 0.170, p = 0.038), septal E/E' ratio (r = 0.344, p = 0.001), lateral E/E' ratio (r = 0.366, p < 0.001), nighttime systolic BP (r = 0.166, p = 0.046), and nighttime diastolic BP (r = 0.188, p = 0.024); however, it correlated negatively with septal and lateral E' velocities (r = 0.268, p = 0.005 and r = 0.236, p = 0.013, respectively). Furthermore, GDF-15 level and nighttime diastolic BP remained independently associated with non-dipper HT. In ROC analysis, optimal cutoff value for GDF-15 was 524.6 ng/L with 56.7% sensitivity and 72.4% specificity (AUC: 0.676, 95% CI: 0.580-0.772, p < 0.05). CONCLUSION: Our results showed GDF-15 upregulation in the non-dipper HT group. GDF-15 and nighttime diastolic BP were independently associated with the non-dipping pattern. This study may suggest possible utilization of GDF-15 in the prediction of non-dipper HT.
Asunto(s)
Ritmo Circadiano/fisiología , Hipertensión Esencial/sangre , Hipertensión Esencial/fisiopatología , Factor 15 de Diferenciación de Crecimiento/sangre , Monitoreo Ambulatorio de la Presión Arterial , Estudios de Casos y Controles , Ecocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios ProspectivosRESUMEN
Background and Objectives: The mean platelet volume (MPV) represents a possible marker of platelet activation. There is an association between the platelet count (PC) and inflammation and platelet reactivity. We assessed the association between the MPV/PC ratio and circadian alterations in blood pressure (BP). Material and Methods: One hundred and twenty subjects in total, 80 hypertensive subjects and 40 healthy subjects (controls), were enrolled in the study group. Twenty four hour ambulatory BP monitoring (ABPM) was applied to all subjects. According to ABPM results, the hypertensive subjects were separated into two groups, such as dippers (n = 40) and non-dippers (n = 40). In all subjects, the collection of venous peripheral blood samples was performed on admission for PC and MPV measurements. Results: The two groups exhibited similar clinical baseline characteristics. A significantly higher MPV/PC ratio was determined in non-dippers compared to that in dippers and normotensives. The higher MPV/PC ratio was observed in non-dippers in comparison with that in dippers and normotensives (0.046 ± 0.007 to 0.032 ± 0.004 fL/[109/L]; 0.046 ± 0.007 to 0.026 ± 0.004 fL/[109/L], p < 0.001, respectively). A receiver operating characteristic (ROC) curve analysis showed that the optimum cut-off value of the MPV/PC ratio for predicting non-dipping patterns in hypertensive patients was 0.036 (area under the curve [AUC]: 0.98, p < 0.001). According to the cut-off value, sensitivity and specificity were found to be 95% and 95%, respectively. Conclusions: The higher MPV/PC ratio was determined in non-dipper hypertensive subjects in comparison with that in dipper hypertensive subjects. An elevation of platelet activity and an increase in thrombus burden are reflected by an increase in the MPV/PC ratio. The MPV/PC ratio may underlie the increase in cardiovascular risk in non-dippers compared to that in dippers.
Asunto(s)
Presión Sanguínea/fisiología , Recuento de Plaquetas/clasificación , Adulto , Plaquetas , Determinación de la Presión Sanguínea/métodos , Monitoreo Ambulatorio de la Presión Arterial/métodos , Distribución de Chi-Cuadrado , Correlación de Datos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recuento de Plaquetas/métodos , Recuento de Plaquetas/estadística & datos numéricosRESUMEN
BACKGROUND: Frontal QRS-T angle is a novel marker of myocardial repolarization, and an increased frontal QRS-T angle associated with adverse cardiac outcomes. Non-dipper hypertension is also associated with adverse cardiac outcomes. This study aimed to investigate the relationship between frontal QRS-T angle and non-dipper status in hypertensive patients without left ventricular hypertrophy (LVH). METHODS: This study included 122 hypertensive patients without LVH. Patients were divided into two groups: dipper hypertension and non-dipper hypertension. The frontal QRS-T angle was calculated from 12-lead electrocardiography. RESULTS: Frontal QRS-T angle (47.9° ± 29.7° vs. 26.7° ± 19.6°, P < 0.001) was significantly higher in patients with non-dipper hypertension than in patients with dipper hypertension. In addition, frontal QRS-T angle was positively correlated with sleeping systolic (r = 0.211, P = 0.020), and diastolic (r = 0.199, P = 0.028) blood pressures (BP), even if they were weak. Multivariate analysis showed that the frontal QRS-T angle was independent predictor of non-dipper status (QR: 1.037, 95% CI: 1.019-1.056, P < 0.001). CONCLUSION: Frontal QRS-T angle is independent predictor of non-dipper status in hypertensive patients without LVH.
Asunto(s)
Presión Sanguínea , Ritmo Circadiano/fisiología , Corazón/fisiopatología , Hipertensión/fisiopatología , Adulto , Anciano , Diástole , Electrocardiografía , Femenino , Humanos , Hipertrofia Ventricular Izquierda/fisiopatología , Masculino , Persona de Mediana Edad , Sueño/fisiología , SístoleRESUMEN
A diminished nocturnal decline in blood pressure (BP) represents a risk factor for cardiovascular disease. To define daytime and nighttime ambulatory BP, clock time-dependent methods are used when information on diary-based sleeping time is unavailable. We aimed to compare fixed-clock intervals with diary records to identify nocturnal BP declines as a predictor of long-term cardiovascular risk among the general population. Data were obtained from 1714 participants with no history of cardiovascular disease in Ohasama, Japan (mean age, 60.6 years; 64.9% women). We defined extreme dippers, dippers, non-dippers, and risers as nocturnal systolic BP decline ≥20%, 10-19%. 0-9%, and <0%, respectively. Over a mean follow-up period of 17.0 years, 206 cardiovascular deaths occurred. Based on diary records, multivariable-adjusted hazard ratios (HRs) for cardiovascular death compared with dippers were 1.24 (95% confidence interval [CI], 0.82-1.87) in extreme dippers, 1.21 (0.87-1.69) in non-dippers, and the highest HR of 2.31 (1.47-3.62) was observed in risers. Using a standard fixed-clock interval (daytime 09:00-21:00; nighttime 01:00-06:00), a nighttime 2 h-early shifted fixed-clock (daytime 09:00-21:00; nighttime 23:00-04:00), or a nighttime 2 h-late shifted fixed-clock (daytime 09:00-21:00; nighttime 03:00-08:00), the HR (95%CI) in risers compared with dippers was 1.57 (1.08-2.27), 2.02 (1.33-3.05), or 1.29 (0.86-1.92), respectively. Although use of diary records remains preferable, the standard and nighttime 2 h-early shifted fixed-clock intervals appear feasible for population-based studies.
Asunto(s)
Presión Sanguínea , Enfermedades Cardiovasculares/mortalidad , Ritmo Circadiano/fisiología , Anciano , Monitoreo Ambulatorio de la Presión Arterial , Femenino , Estudios de Seguimiento , Humanos , Japón/epidemiología , Masculino , Persona de Mediana Edad , Factores de Riesgo , Sueño , Sístole , Factores de TiempoRESUMEN
Clinicians should take initiatives to establish ambulatory blood pressure monitoring (ABPM) services in their own practice, or to ensure that they have access to such services elsewhere. Whenever possible, ABPM should be performed in suitable cases, where it is likely to deliver clinically useful information for making a correct diagnosis, or for tailoring the anti-hypertensive treatment regimen for each individual patient. ABPM is clinically useful, among others, for identifying people with "masked normotension", "masked hypertension", "sleep-time hypertension", and "reduced decline of sleep-time blood pressure". This review briefly outlines the rationales for the use of ABPM, interpretations of the ABPM-derived parameters, and the advantages of ABPM in decision making in the management of hypertension.
Asunto(s)
Antihipertensivos/uso terapéutico , Monitoreo Ambulatorio de la Presión Arterial , Presión Sanguínea/efectos de los fármacos , Hipertensión/diagnóstico , Hipertensión/tratamiento farmacológico , Monitoreo Ambulatorio de la Presión Arterial/normas , Ritmo Circadiano , Humanos , Hipertensión/fisiopatología , Hipertensión Enmascarada/diagnóstico , Hipertensión Enmascarada/tratamiento farmacológico , Hipertensión Enmascarada/fisiopatología , Valor Predictivo de las Pruebas , Estándares de Referencia , Reproducibilidad de los Resultados , Resultado del Tratamiento , Hipertensión de la Bata Blanca/diagnóstico , Hipertensión de la Bata Blanca/tratamiento farmacológico , Hipertensión de la Bata Blanca/fisiopatologíaRESUMEN
BACKGROUND: Fragmented QRS (fQRS) has been shown to be associated with poor outcome in various cardiovascular diseases. Non-dipper hypertension is also associated with increased cardiovascular mortality. The aim of our study is to investigate the relationship between fQRS and non-dipper status in hypertensive patients without left ventricular hypertrophy (LVH). METHODS: This study included 106 hypertensive patients without LVH. Patients were divided into two groups: dipper hypertension and non-dipper hypertension. The presence of fQRS was analyzed from surface electrocardiography. RESULTS: Frequency of fQRS (56% vs. 19.6%, p < 0.001) and mean number of leads with fQRS (1.9 ± 1.7 vs. 0.6 ± 1.0, p < 0.001) were significantly higher in patients with non-dipper hypertension compared to dipper hypertension. In addition, the number of leads with fQRS was positively correlated with systolic (r = 0.334, p < 0.001) and diastolic (r = 0.280, p = 0.004) blood pressures (BP). By a multivariate regression analysis, fQRS (OR: 5.207, 95% CI: 2.195-12.353, p < 0.001) was found to be independent predictor of non-dipper status. CONCLUSION: fQRS is independent predictor of non-dipper status in hypertensive patients without LVH. Also, the higher number of leads with fQRS is associated with higher sleep systolic and diastolic BPs.
Asunto(s)
Arritmias Cardíacas/fisiopatología , Hipertensión/fisiopatología , Enfermedades Cardiovasculares/etiología , Diástole/fisiología , Ecocardiografía , Electrocardiografía , Femenino , Humanos , Hipertrofia Ventricular Izquierda/fisiopatología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sueño/fisiología , Sístole/fisiologíaRESUMEN
BACKGROUND: Only a few studies have evaluated the abnormalities of ambulatory blood pressure (ABP) in patients with nephrotic syndrome (NS). METHODS: The 24-h ABPs were measured in primary NS patients with acute onset of disease and analyzed in relation to the clinical variables. RESULTS: Our subjects comprised 21 patients: 17 with minimal change disease and 4 with focal segmental glomerulosclerosis. Of these patients, 8 (38%) had daytime hypertension, 13 (62%) had nighttime hypertension, and 13 (62%) were non-dippers (nighttime-to-daytime ratio of ABP: NDR > 0.9). The serum sodium level was correlated with the average 24-h ABP and NDR, after adjustment for other clinical variables, such as the increase in body weight, serum albumin level, and urinary protein excretion. The data from repeated ABP measurements, before and after the achievement of remission, showed a marked decrease in the average 24-h ABP after remission. Furthermore, change in the serum sodium level was significantly correlated with the change in NDR. CONCLUSION: These results suggest that alteration in renal handling of sodium and water, which might be reflected in serum sodium level, is involved in the abnormality of circadian blood pressure in primary NS patients.
Asunto(s)
Presión Sanguínea , Ritmo Circadiano , Glomeruloesclerosis Focal y Segmentaria/fisiopatología , Hipertensión/fisiopatología , Nefrosis Lipoidea/fisiopatología , Síndrome Nefrótico/fisiopatología , Adulto , Anciano , Determinación de la Presión Sanguínea , Monitoreo Ambulatorio de la Presión Arterial , Femenino , Glomeruloesclerosis Focal y Segmentaria/complicaciones , Glomeruloesclerosis Focal y Segmentaria/metabolismo , Humanos , Hipertensión/etiología , Hipertensión/metabolismo , Riñón/fisiopatología , Masculino , Persona de Mediana Edad , Nefrosis Lipoidea/complicaciones , Nefrosis Lipoidea/metabolismo , Síndrome Nefrótico/etiología , Síndrome Nefrótico/metabolismo , Sodio/metabolismoRESUMEN
Objective The aim of this study was to investigate the correlation between non-dipper circadian rhythm of blood pressure (BP) and left ventricular hypertrophy (LVH) in patients with chronic kidney disease (CKD). Methods and results All 257 patients with stage 1 to 5 CKD were enrolled in the study and classified into a CKD1-3 group and a CKD4-5 group according to renal function. The parameters and circadian rhythm of BP were measured by a GE Marquette Tonoport V Eng dynamic sphygmomanometer, and cardiac structure was examined by echocardiography. The incidence of abnormal circadian BP rhythm (non-dipper rhythm) was quite high (75.4% in all enrolled patients and 71.3% in the patients with normal BP levels) in CKD patients and increased with the deterioration of renal function. Changes of cardiac structure such as LVH in patients with non-dipper BP were more distinct than in patients with dipper BP. The development of left ventricular mass index (LVMI) correlated positively with the incidence of non-dipper BP rhythm. Multiple regression analysis showed that 24-h systolic BP (ß = 0.417, P < 0.01), triglycerides (TG) (ß = -0.132, P = 0.007), Hb (ß = -0.394, P = 0.016) and gender (ß = 0.158, P = 0.039) were independent risk factors of LVMI. Conclusions The incidence of non-dipper circadian rhythm of blood pressure was quite high in CKD patients and increased with the deterioration of renal function. Non-dipper circadian rhythm of BP is closely related with LVMI.
Asunto(s)
Presión Sanguínea/fisiología , Ritmo Circadiano , Ventrículos Cardíacos/fisiopatología , Hipertrofia Ventricular Izquierda/fisiopatología , Insuficiencia Renal Crónica/complicaciones , Adulto , Anciano , Monitoreo Ambulatorio de la Presión Arterial , Ecocardiografía , Femenino , Estudios de Seguimiento , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Hipertrofia Ventricular Izquierda/complicaciones , Hipertrofia Ventricular Izquierda/diagnóstico , Masculino , Persona de Mediana Edad , Diálisis Renal , Insuficiencia Renal Crónica/fisiopatología , Estudios Retrospectivos , Adulto JovenRESUMEN
Many of the elderly Kazakhs have been found to exhibit non-dipping blood pressure variations (BPV). Such variations are seen in both normotensive and hypertensive Kazakhs. The purpose of this study was (1) to determine whether middle-aged Kazakhs also include large numbers of non-dippers, (2) to compare the characteristics of non-dipping and dipping, and (3) to clarify the mechanisms responsible for non-dipping type BPV by examining the autonomic nervous activity and physical activity. We performed ambulatory blood pressure (BP) monitoring. The subjects were divided into two groups (dipping and non-dipping type). We monitored the subjects' physical activity with accelerometry and assessed their autonomic nerve activity by performing a frequency domain analysis of their heart rate variability (HRV). The power spectral density (PSD) of the HRV was calculated using fast Fourier transformation. We analyzed the systolic blood pressure (SBP) variations with the maximum entropy method (MEM). The dippers and non-dippers accounted for 48% and 52% of the subjects, respectively. MEM analysis revealed that the SBP variations of the non-dippers exhibited a 24 hour periodicity with a very weak PSD as well as an ultradian periodicity. The non-dippers exhibited higher low-frequency/high-frequency (LF/HF) ratio and lower HF/(LF + HF) ratios than the dippers, particularly during the nighttime. In addition, the non-dippers performed less physical activity than the dippers. These differences in cardiac autonomic function and physical activity might contribute to the generation of a weak circadian rhythm in SBP, and thus, ultimately lead to the non-dipping SBP variations observed in non-dipper Kazakhs.
Asunto(s)
Presión Sanguínea/fisiología , Ritmo Circadiano/fisiología , Actividad Motora/fisiología , Sistema Nervioso Simpático/fisiopatología , Acelerometría , Adulto , Pueblo Asiatico , Sistema Nervioso Autónomo , Monitoreo Ambulatorio de la Presión Arterial , Estudios de Casos y Controles , Estudios Transversales , Electrocardiografía Ambulatoria , Femenino , Frecuencia Cardíaca , Humanos , Hipertensión/etnología , Hipertensión/fisiopatología , Kazajstán , Masculino , Población BlancaRESUMEN
This study was undertaken to evaluate the differences in chronotherapeutic effects of angiotensin-II receptor blockers, valsartan and olmesartan in hypertensive patients with non-dipper blood pressure (BP) pattern during valsartan at morning. Ninety four patients were enrolled, and 40 patients were judged to be non-dippers. In these patients, same dose of valsartan was changed to evening (Val-E, n = 12), or olmesartan (equivalent dose of valsartan) was given at morning (Olm-M, n = 13) or evening (Olm-E, n = 15) for 4 months. BP decreased during sleep and increased during waking hours in Val-E group. In Olm-M and Olm-E groups, BP decreased during sleep and waking hours. Percent reduction in BP at night-time compared to BP at waking hours significantly increased after changing the dose regimen in each group. Serum creatinine decreased and estimated glomerular filtration rate (eGFR) elevated in Olm-M and Olm-E, but not Val-E groups. Positive correlation between systolic BP (SBP) during sleep and serum creatinine, and negative correlation between SBP during sleep and eGFR were detected. These data suggest that dipper BP pattern could be obtained by chronotherapeutic approach using valsartan and olmesartan in non-dipper patients with valsartan at morning. Morning and evening olmesartan, but not evening valsartan improved renal function in these patients.
Asunto(s)
Antihipertensivos/uso terapéutico , Cronoterapia de Medicamentos , Hipertensión/tratamiento farmacológico , Imidazoles/uso terapéutico , Tetrazoles/uso terapéutico , Valsartán/uso terapéutico , Anciano , Antihipertensivos/administración & dosificación , Antihipertensivos/farmacología , Presión Sanguínea/efectos de los fármacos , Creatinina/sangre , Femenino , Tasa de Filtración Glomerular/efectos de los fármacos , Humanos , Hipertensión/sangre , Imidazoles/administración & dosificación , Imidazoles/farmacología , Masculino , Persona de Mediana Edad , Tetrazoles/administración & dosificación , Tetrazoles/farmacología , Valsartán/administración & dosificación , Valsartán/farmacologíaRESUMEN
PURPOSE: This study aimed to determine blood pressure characteristics and long-term progress in patients with white coat hypertension (WCH) and obstructive sleep apnea (OSA). METHODS: Systolic blood pressure (SBP) and diastolic blood pressure (DBP) and sleep test results over a period of 26 months were analyzed from WCH patients with OSA (n = 28), WCH patients (n = 23), and healthy control subjects (n = 27). RESULTS: At the end of observation, WCH patients with OSA presented significantly increased daytime and nighttime BP and lower diurnal difference of SBP (all Ps < 0.05) and the increased rate of "non-dipper" status (SBP 28.6 %, DBP 32.1 %) was significantly higher when compared with WCH and control groups (all Ps < 0.01). Sustained hypertension was observed in 42.8 % of the WCH patients with OSA, which was significantly higher than that in the WCH and control groups (Ps < 0.01) and was predicted by non-dipper status via 24-h ambulatory SBP/DBP monitoring (Ps < 0.05). CONCLUSION: WCH may represent a prehypertension status, which could develop into sustained hypertension with OSA.
Asunto(s)
Apnea Obstructiva del Sueño/diagnóstico , Apnea Obstructiva del Sueño/fisiopatología , Hipertensión de la Bata Blanca/diagnóstico , Hipertensión de la Bata Blanca/fisiopatología , Adulto , Anciano , Ritmo Circadiano/fisiología , Estudios Transversales , Susceptibilidad a Enfermedades , Femenino , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Factores de Riesgo , Apnea Obstructiva del Sueño/epidemiología , Hipertensión de la Bata Blanca/epidemiologíaRESUMEN
UNLABELLED: Abstract Objective: Patients with a lack of nocturnal decline in blood pressure (BP) are at an increased risk for cardiovascular events. Mean platelet volume (MPV) and soluble CD40 ligand (sCD40L) are accepted biomarkers of platelet activation and considered as a risk factor for cardiovascular disease. The aim of this study was to determine whether MPV and sCD40L levels are higher in non-dipper hypertensive (NDHT) patients than in dipper hypertensive (DHT) patients and healthy controls. METHODS: 124 consecutive patients were included to this study. Patients were divided into three groups: NDHT patient group [n = 43; mean age 51.8 ± 6.6; 31 males (72.1%)]; DHT patient group [n = 41; mean age 50.2 ± 7.3; 22 males (53.7%)]; and normotensive group [n = 40; mean age 49.9 ± 6.7; 22 males (55%)]. Physical examination, laboratory work-up and 24-h ABPM were performed for all participants. RESULTS: The sCD40L and MPV levels were significantly higher in the NDHT group than in the DHT and normotensive groups (p < 0.05). In correlation analysis, MPV, 24-h systolic blood pressure (SBP), 24-h diastolic blood pressure (DBP), night-time SBP and night-time DBP were positively correlated with sCD40L. CONCLUSION: Our study demonstrated that MPV and sCD40L levels were significantly higher in NDHT patients compared to DHT and normotensive patients. sCD40L levels were positively correlated with MPV, 24-h SBP, 24-h DBP, night-time SBP and night-time DBP.