Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.749
Filtrar
Más filtros

Intervalo de año de publicación
1.
Nano Lett ; 24(27): 8257-8267, 2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-38920296

RESUMEN

Osseointegration is the most important factor determining implant success. The surface modification of TiO2 nanotubes prepared by anodic oxidation has remarkable advantages in promoting bone formation. However, the mechanism behind this phenomenon is still unintelligible. Here we show that the nanomorphology exhibited open and clean nanotube structure and strong hydrophilicity, and the nanomorphology significantly facilitated the adhesion, proliferation, and osteogenesis differentiation of stem cells. Exploring the mechanism, we found that the nanomorphology can enhance mitochondrial oxidative phosphorylation (OxPhos) by activating Piezo1 and increasing intracellular Ca2+. The increase in OxPhos can significantly uplift the level of acetyl-CoA in the cytoplasm but not significantly raise the level of acetyl-CoA in the nucleus, which was beneficial for the acetylation and stability of ß-catenin and ultimately promoted osteogenesis. This study provides a new interpretation for the regulatory mechanism of stem cell osteogenesis by nanomorphology.


Asunto(s)
Diferenciación Celular , Canales Iónicos , Osteogénesis , Propiedades de Superficie , Titanio , beta Catenina , Osteogénesis/efectos de los fármacos , Titanio/química , Titanio/farmacología , beta Catenina/metabolismo , Canales Iónicos/metabolismo , Diferenciación Celular/efectos de los fármacos , Animales , Proliferación Celular/efectos de los fármacos , Oseointegración/efectos de los fármacos , Ratones , Nanoporos , Nanotubos/química , Humanos , Células Madre Mesenquimatosas/citología , Células Madre Mesenquimatosas/efectos de los fármacos , Células Madre Mesenquimatosas/metabolismo , Fosforilación Oxidativa/efectos de los fármacos , Prótesis e Implantes , Adhesión Celular/efectos de los fármacos
2.
Biochem Biophys Res Commun ; 703: 149647, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38350211

RESUMEN

The establishment of an osseointegration is crucial for the long-term stability and functionality of implant materials, and early angiogenesis is the key to successful osseointegration. However, the bioinertness of titanium implants affects osseointegration, limiting their clinical application. In this study, inspired by the rapid polarization of macrophages following the phagocytosis of bacteria, we developed bacteroid cerium oxide particles; these particles were composed of CeO2 and had a size similar to that of Bacillus (0.5 µ m). These particles were constructed on the implant surfaces using a hydrothermal method. In vitro experiments demonstrated that the particles effectively decreased the reactive oxygen species (ROS) levels in macrophages (RAW264.7). Furthermore, these particles exerted effects on M1 macrophage polarization, enhanced nitric oxide (NO) secretion to promote vascular regeneration, and facilitated rapid macrophage transition to the M2 phenotype. Subsequently, the particles facilitated human umbilical vein endothelial cell (HUVEC) migration. In vivo studies showed that these particles rapidly stimulated innate immune responses in animal models, leading to enhanced angiogenesis around the implant and improved osseointegration. In summary, the presence of bacteroid cerium oxide particles on the implant surface regulated and accelerated macrophage polarization, thereby enhancing angiogenesis during the immune response and improving peri-implant osseointegration.


Asunto(s)
Cerio , Oseointegración , Animales , Humanos , Macrófagos , Cerio/farmacología , Inmunidad Innata , Neovascularización Patológica , Titanio , Osteogénesis , Propiedades de Superficie
3.
Biochem Biophys Res Commun ; 727: 150316, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-38959732

RESUMEN

Type 2 diabetes (T2D) is on a notable rise worldwide, which leads to unfavorable outcomes during implant treatments. Surface modification of implants and exosome treatment have been utilized to enhance osseointegration. However, there has been insufficient approach to improve adverse osseointegration in T2D conditions. In this study, we successfully loaded TNF-α-treated mesenchymal stem cell (MSC)-derived exosomes onto micro/nano-network titanium (Ti) surfaces. TNF-α-licensed exosome-integrated titanium (TNF-exo-Ti) effectively enhanced M2 macrophage polarization in hyperglycemic conditions, with increased secretion of anti-inflammatory cytokines and decreased secretion of pro-inflammatory cytokines. In addition, TNF-exo-Ti pretreated macrophage further enhanced angiogenesis and osteogenesis of endothelial cells and bone marrow MSCs. More importantly, TNF-exo-Ti markedly promoted osseointegration in T2D mice. Mechanistically, TNF-exo-Ti activated macrophage autophagy to promote M2 polarization through inhibition of the PI3K/AKT/mTOR pathway, which could be abolished by PI3K agonist. Thus, this study established TNF-α-licensed exosome-immobilized titanium surfaces that could rectify macrophage immune states and accelerate osseointegration in T2D conditions.


Asunto(s)
Autofagia , Diabetes Mellitus Tipo 2 , Exosomas , Macrófagos , Ratones Endogámicos C57BL , Oseointegración , Titanio , Factor de Necrosis Tumoral alfa , Titanio/química , Titanio/farmacología , Animales , Exosomas/metabolismo , Autofagia/efectos de los fármacos , Macrófagos/metabolismo , Macrófagos/efectos de los fármacos , Oseointegración/efectos de los fármacos , Factor de Necrosis Tumoral alfa/metabolismo , Factor de Necrosis Tumoral alfa/farmacología , Ratones , Diabetes Mellitus Tipo 2/metabolismo , Masculino , Células Madre Mesenquimatosas/metabolismo , Células Madre Mesenquimatosas/efectos de los fármacos , Células Madre Mesenquimatosas/citología , Polaridad Celular/efectos de los fármacos , Osteogénesis/efectos de los fármacos , Activación de Macrófagos/efectos de los fármacos , Diabetes Mellitus Experimental/metabolismo
4.
J Periodontal Res ; 2024 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-38764144

RESUMEN

AIMS: To histologically compare osseointegration and crestal bone healing between newly introduced tapered, self-cutting bone-level test implants and tapered bone-level control implants in sites with fully healed sites. METHODS: Sixty-six implants (33 test, 33 control) were placed 1 mm subcrestally in a minipig model and underwent qualitative histologic and quantitative histometric analyses after 3, 6 and 12 weeks of submerged healing. The primary and secondary outcomes were the bone-to-implant contact (BIC) and first bone-to-implant contact (fBIC). Outcomes between the test and control implants were statistically compared. RESULTS: The BIC values of the test implants were comparable and non-inferior over the time points studied, except for the 12 weeks time point which showed statistically significantly higher BIC values of the test (88.07 ± 5.35%) compared to the control implants (80.88 ± 7.51%) (p = .010). Similarly comparable and non-inferior were the fBIC values, except for the 6-week outcome, which showed statistically higher values for the test (-546.5 ± 450.80 µm) compared to the control implants (-75.7 ± 100.59 µm). fBIC results for the test implants were qualitatively more stable and consistent between test time points. CONCLUSION: Novel self-cutting bone-level test implants demonstrated superior osseointegration and similar bone levels compared to conventional bone-level implants after a healing period of 12 weeks in healed ridges.

5.
Artículo en Inglés | MEDLINE | ID: mdl-38963167

RESUMEN

OBJECTIVE: The aim of this study was to explore the effect of depression and selective serotonin reuptake inhibitors on implant osseointegration and bone healing. METHODS: Forty-eight 6- to 8-week-old SPF Sprague-Dawley male rats were randomly divided into four groups: the Control group, the Fluoxetine group, the Depression group and the De&Flu group. The rats in the Depression group and the De&Flu group were subjected to a depression modelling process, and the rats in the Control group and the Fluoxetine group were raised normally. Then, a titanium implant was placed in the right tibia of each rat. In the Fluoxetine group and De&Flu group, fluoxetine was injected subcutaneously daily, while subcutaneously injecting physiological saline in the Control group and Depression group. Collecting serum from the rats used for ELISA. The surgical area was cut for microcomputed tomography and histology observation. RESULTS: After 12 weeks, bone mineral density was lower in the De&Flu group than in the Control group, Depression group and Fluoxetine group. Bone mineral density was also lower in the Depression group and the Fluoxetine group than in the Control group. The percentage of bone-implant contact (BIC%) in De&Flu rats was lower than in the Control, Depression and Fluoxetine groups. The BIC% in the Depression group and the Fluoxetine group was lower than in the Control group. CONCLUSIONS: Depression and fluoxetine negatively affect bone density and implant osseointegration independently, and this damaging effect is exacerbated when both factors are present. The mechanism may be related to the dysregulation of the hypothalamic-pituitary-adrenal axis and inflammation in the body.

6.
Artículo en Inglés | MEDLINE | ID: mdl-39032079

RESUMEN

PURPOSE: To histometrically compare the osseointegration and crestal bone healing of a novel tapered, self-cutting tissue-level test implant with a standard tissue-level control implant in a submerged healing regimen. MATERIALS AND METHODS: In a mandibular minipig model, implants were inserted and evaluated histometrically after a healing period of 3, 6, and 12 weeks. The primary outcome was the evaluation of bone-to-implant contact (BIC) and secondary outcomes were primary stability as per insertion torque and first BIC (fBIC). Outcomes for the test and control implants were compared using Wilcoxon signed-rank tests and mixed linear regression models. RESULTS: Insertion torque values were significantly higher for the test (50.0 ± 26.4 Ncm) compared to the control implants (35.2 ± 19.7 Ncm, p = .0071). BIC values of test implants were non-inferior to those of control implants over the investigated study period. After 12 weeks, the corresponding values measured were 81.62 ± 11.12% and 90.41 ± 4.81% (p = .1763) for test and control implants, respectively. Similarly, no statistical difference was found for fBIC values, except for the 12 weeks outcome that showed statistically lower values for the test (-675.58 ± 590.88 µm) compared to control implants (-182.75 ± 197.40 µm, p = .0068). CONCLUSIONS: Novel self-cutting tissue-level implants demonstrated noninferior osseointegration and crestal bone height maintenance to the tissue-level implants. Histometric outcomes between both implants demonstrated test implants were statistically noninferior to control implants, despite substantial differences in the bone engagement mechanism and resulting differences in insertion torque and qualitative bone healing patterns.

7.
Clin Oral Implants Res ; 35(1): 40-51, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37855174

RESUMEN

AIM: A new implant system encompassing implants with a tri-oval cross-sectional design and a simplified site preparation protocol at low speed and no irrigation has been developed. The objective of this study was to assess the safety and efficacy of the new implant system using the minipig intraoral dental implant model. METHODS: Eight Yucatan minipigs were included. Twelve weeks after extractions, four implants per animal were randomly placed and allowed to heal transmucosal for 13 weeks: two Ø3.5 × 10 mm implants with a back-tapered collar and circular cross-section (control) and two Ø3.5 × 11 mm implants with tri-oval collar and cross-section (test). MicroCT and histological analysis was performed. RESULTS: Thirty-two implants were placed; one implant for the control group was lost. Histologically, BIC was higher in the test compared with the control group (74.1% vs. 60.9%, p < .001). At the platform level, inflammation was statistically significantly higher albeit mild in the test compared with the control group. No other significant differences were observed between groups. MicroCT analysis showed that bone-to-implant-contact (BIC) and trabecular thickness were statistically significantly higher for the test than the control group. Test group had significantly higher first BIC distance than controls on lingual sites. CONCLUSIONS: The present study results support the safety and efficacy of the new dental implant system and simplified site preparation protocol; human studies should be carried out to confirm these findings.


Asunto(s)
Implantación Dental Endoósea , Implantes Dentales , Animales , Estudios Transversales , Implantación Dental Endoósea/métodos , Oseointegración , Porcinos , Porcinos Enanos
8.
Clin Oral Implants Res ; 35(4): 427-442, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38314615

RESUMEN

OBJECTIVE: This study aimed to synthesize zinc-incorporated nanowires structure modified titanium implant surface (Zn-NW-Ti) and explore its superior osteogenic and antibacterial properties in vitro and in vivo. MATERIALS AND METHODS: Zn-NW-Ti was synthesized via displacement reactions between zinc sulfate solutions and the titanium (Ti) surface, which was pretreated by hydrofluoric acid etching and hyperthermal alkalinization. The physicochemical properties of the Zn-NW-Ti surface were examined. Moreover, the biological effects of Zn-NW-Ti on MC3T3-E1 cells and its antibacterial property against oral pathogenic bacteria (Staphylococcus aureus, Porphyromonas gingivalis, and Actinobacillus actinomycetemcomitans) compared with sandblasted and acid-etched Ti (SLA-Ti) and nanowires modified Ti (NW-Ti) surface were assessed. Zn-NW-Ti and SLA-Ti modified implants were inserted into the anterior extraction socket of the rabbit mandible with or without exposure to the mixed bacterial solution (S. aureus, P. gingivalis, and A. actinomycetemcomitans) to investigate the osteointegration and antibacterial performance via radiographic and histomorphometric analysis. RESULTS: The Zn-NW-Ti surface was successfully prepared. The resultant titanium surface appeared as a nanowires structure with hydrophilicity, from which zinc ions were released in an effective concentration range. The Zn-NW-Ti surface performed better in facilitating the adhesion, proliferation, and differentiation of MC3T3-E1 cells while inhibiting the colonization of bacteria compared with SLA-Ti and NW-Ti surface. The Zn-NW-Ti implant exhibited enhanced osseointegration in vivo, which was attributed to increased osteogenic activity and reduced bacterial-induced inflammation compared with the SLA-Ti implant. CONCLUSIONS: The Zn-incorporated nanowires structure modified titanium implant surface exhibited improvements in osteogenic and antibacterial properties, which optimized osteointegration in comparison with SLA titanium implant surface.


Asunto(s)
Implantes Dentales , Nanocables , Animales , Conejos , Titanio/farmacología , Titanio/química , Staphylococcus aureus , Antibacterianos/farmacología , Oseointegración , Bacterias , Zinc/química , Zinc/farmacología , Propiedades de Superficie , Osteogénesis
9.
Artículo en Inglés | MEDLINE | ID: mdl-38804531

RESUMEN

OBJECTIVES: The glow discharge plasma (GDP) procedure has proven efficacy in grafting allylamine onto zirconia dental implant surfaces to enhance osseointegration. This study explored the enhancement of zirconia dental implant properties using GDP at different energy settings (25, 50, 75, 100, and 200 W) both in vitro and in vivo. MATERIALS AND METHODS: In vitro analyses included scanning electron microscopy, wettability assessment, energy-dispersive X-ray spectroscopy, and more. In vivo experiments involved implanting zirconia dental implants into rabbit femurs and later evaluation through impact stability test, micro-CT, and histomorphometric measurements. RESULTS: The results demonstrated that 25 and 50 W GDP allylamine grafting positively impacted MG-63 cell proliferation and increased alkaline phosphatase activity. Gene expression analysis revealed upregulation of OCN, OPG, and COL-I. Both 25 and 50 W GDP allylamine grafting significantly improved zirconia's surface properties (p < .05, p < .01, p < .001). However, only 25 W allylamine grafting with optimal energy settings promoted in vivo osseointegration and new bone formation while preventing bone level loss around the dental implant (p < .05, p < .01, p < .001). CONCLUSIONS: This study presents a promising method for enhancing Zr dental implant surface's bioactivity.

10.
Clin Oral Implants Res ; 35(2): 230-241, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38012845

RESUMEN

AIM: The aim of the study was to evaluate the 5 years clinical outcomes associated with implant-level connection (IL) versus abutment-level connection (AL) for implants with an internal conical connection (ICC) supporting a screw-retained fixed partial denture. MATERIALS AND METHODS: Fifty patients with 119 implants were randomly allocated to either the AL or IL group. Radiographic (Marginal bone loss) and clinical outcomes (Bleeding on Probing, probing pocket depth, plaque accumulation, incidence of peri-implantitis and peri-implant mucositis as well as prosthetic complications) were collected and compared at 1, 2, 3, and 5 years. A linear mixed model was used to evaluate the differences between groups. RESULTS: Five years after treatment, the MBL change was not significantly different between the groups at any point. The MBL was 0.23 ± 0.64 mm (AL) and 0.23 ± 0.29 mm (IL). The bleeding on Probing was 44% (AL) and 45% (IL) (p = .89). The mean probing depth was 2.91 ± 1.01 mm (AL) and 3.51 ± 0.67 mm (IL). This difference between the groups was statistically significant but clinical insignificant. Presence of plaque was slightly higher (p = .06) in the IL group (34.4%) compared with the AL group (26.3%). The overall technical, biological, and prosthetic complication rates were similar between groups. None of the implants developed peri-implantitis during the entire follow-up period. CONCLUSION: The results of this clinical trial indicated that all clinical and radiographical parameters were clinically comparable between the study groups.


Asunto(s)
Implantes Dentales , Periimplantitis , Humanos , Tornillos Óseos , Implantes Dentales/efectos adversos , Periimplantitis/etiología
11.
Clin Oral Implants Res ; 35(1): 1-20, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37840388

RESUMEN

INTRODUCTION: The radiographic examination of alveolar bone using 3D radiographic examination is essential in dental implant treatment planning. Our study aimed to systematically review and quantitatively analyze the correlation between alveolar bone parameters, specifically bone density and cortical bone thickness, assessed using cone beam computed tomography (CBCT) and/or multidetector computed tomography (MDCT); and primary implant stability (PIS) determined using implant stability quotient (ISQ), Periotest® value (PTV), and insertion torque value (ITV). METHODS: This review was registered in the PROSPERO database (registration number CRD42022307245). An electronic literature search was conducted on the PubMed, SCOPUS, and Web of Science databases for papers published until February 2022. The Quality Assessment in Prognostic Studies (QUIPS) tool was used to assess risk of bias. Meta-analyses were conducted to calculate the estimated average correlation coefficient based on a multilevel random-effects model, followed by subgroup analysis. RESULTS: Twenty-six studies were included in this review, consisting of 17 prospective cohort studies, eight retrospective cohort studies, and one nonrandomized controlled trial. A total of 3109 implants placed in 1171 subjects were analyzed. Twenty-three studies were evaluated using meta-analysis. The alveolar bone condition was significantly correlated with ISQ (r = 0.60; p < .001), IT (r = 0.52; p < .001), and PTV (r = -0.42; p < .05). CONCLUSION: Alveolar bone condition is significantly associated with PIS. Low bone density and thin cortical bone can lead to low PIS; therefore, modification of treatment planning and surgical procedures might be needed to avoid poor osseointegration.


Asunto(s)
Implantación Dental Endoósea , Implantes Dentales , Retención de Prótesis Dentales , Humanos , Densidad Ósea , Implantación Dental Endoósea/métodos , Estudios Prospectivos , Estudios Retrospectivos , Torque
12.
Artículo en Inglés | MEDLINE | ID: mdl-38819108

RESUMEN

OBJECTIVES: The aim of the present study was to compare a novel tapered, double-threaded self-tapping tissue-Level design implant (TLC) to a well-established parallel walled tissue-level (TL) implant in terms of primary and secondary stability over time. MATERIALS AND METHODS: Test TLC (n = 10/per timepoint) and control TL (n = 10/per timepoint) implants were placed in the mandible of minipigs and left for submerged healing for 3, 6, and 12 weeks. Maximum insertion torque and implant stability quotient (ISQ) were measured for each implant at placement. Osseointegration and cortical bone maintenance were histologically evaluated by measuring total bone-to-implant contact (BIC) and first bone-to-implant contact (fBIC). RESULTS: A significantly higher maximum insertion torque was measured for the test implant TLC compared to the control TL implant (57.83 ± 24.73 Ncm and 22.62 ± 23.16 Ncm, respectively; p < .001). The mean ISQ values were comparable between the two implant types (75.00 ± 6.70 for TL compared to 75.40 ± 3.20 for TLC, p = .988). BIC was comparable between both implant types at each of the evaluated time points. The fBIC was found to be significantly more coronal at 12 weeks for the TLC implant compared to the TL implant (0.31 ± 0.83 mm for TLC compared to -0.22 ± 0.85 for TL, p = .027). CONCLUSION: The novel tapered tissue level design implant showed improved primary stability and an overall improved crestal bone height maintenance compared to the parallel walled design at 12 weeks.

13.
Clin Oral Implants Res ; 35(7): 729-738, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38629945

RESUMEN

OBJECTIVES: The present study was conducted to evaluate the reproducibility of Lekholm and Zarb classification system (L&Z) for bone quality assessment of edentulous alveolar ridges and to investigate the potential of a data-driven approach for bone quality classification. MATERIALS AND METHODS: Twenty-six expert clinicians were asked to classify 110 CBCT cross-sections according to L&Z classification (T0). The same evaluation was repeated after one month with the images put in a different order (T1). Intra- and inter-examiner agreement analyses were performed using Cohen's kappa coefficient (CK) and Fleiss' kappa coefficient (FK), respectively. Additionally, radiomic features extraction was performed from 3D edentulous ridge blocks derived from the same 110 CBCTs, and unsupervised clustering using 3 different clustering methods was used to identify patterns in the obtained data. RESULTS: Intra-examiner agreement between T0 and T1 was weak (CK 0.515). Inter-examiner agreement at both time points was minimal (FK at T0: 0.273; FK at T1: 0.243). The three different unsupervised clustering methods based on radiomic features aggregated the 110 CBCTs in three groups in the same way. CONCLUSIONS: The results showed low agreement among clinicians when using L&Z classification, indicating that the system may not be as reliable as previously thought. The present study suggests the possible application of a reproducible data-driven approach based on radiomics for the classification of edentulous alveolar ridges, with potential implications for improving clinical outcomes. Further research is needed to determine the clinical significance of these findings and to develop more standardized and accurate methods for assessing bone quality of edentulous alveolar ridges.


Asunto(s)
Proceso Alveolar , Tomografía Computarizada de Haz Cónico , Humanos , Tomografía Computarizada de Haz Cónico/métodos , Reproducibilidad de los Resultados , Proceso Alveolar/diagnóstico por imagen , Proceso Alveolar/patología , Análisis por Conglomerados , Variaciones Dependientes del Observador , Arcada Edéntula/diagnóstico por imagen , Radiómica
14.
Oral Dis ; 2024 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-39177011

RESUMEN

OBJECTIVE: Estimate the impact of Adiponectin receptors agonist (AdipoRon) on dental implant osseointegration in alveolar bone and explore the possible mechanism between saliva microbiota and AdipoRon in diabetic mice. MATERIALS AND METHODS: Sixty C57BL/6 mice (male, 8 weeks old) were divided randomly into four groups according to different doses of AdipoRon: normoglycemic control group; DM control group; DM with a low dose of AdipoRon (5 mg/kg/day); and DM with a high dose of AdipoRon (50 mg/kg/day). Then, dental implants were placed in the palatal root socket in the first molar extraction mouse model. Micro-computed tomography, histology examination, immunohistochemical staining, and oral microbiota were explored to evaluate implant osseointegration. RESULTS: AdipoRon treatment at 50 mg/kg markedly promoted dental implant osseointegration in diabetic mice, but AdipoRon treatment at 5 mg/kg was not effective. Moreover, distinct differences in the oral microbiota composition were shown between the diabetic mice and diabetic mice treated with AdipoRon at 50 mg/kg. CONCLUSION: AdipoRon treatment at 50 mg/kg in diabetic mice could significantly increase dental implant osseointegration. The salivary microbiota might participate in the accelerated osseointegration progress of dental implants in AdipoRon treatment.

15.
J Biomech Eng ; 146(10)2024 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-38668718

RESUMEN

Creating the optimal environment for effective and long term osseointegration is a heavily researched and sought-after design criteria for orthopedic implants. A validated multimaterial finite element (FE) model was developed to replicate and understand the results of an experimental in vivo push-out osseointegration model. The FE model results closely predicted global force (at 0.5 mm) and stiffness for the 50-90% porous implants with an r2 of 0.97 and 0.98, respectively. In addition, the FE global force at 0.5 mm showed a correlation to the maximum experimental forces with an r2 of 0.90. The highest porosity implants (80-90%) showed lower stiffnesses and more equitable load sharing but also failed at lower a global force level than the low porosity implants (50-70%). The lower strength of the high porosity implants caused premature plastic deformation of the implant itself during loading as well as significant deformations in the ingrown and surrounding bone, resulting in lower overall osseointegration strength, consistent with experimental measurements. The lower porosity implants showed a balance of sufficient bony ingrowth to support osseointegration strength coupled with implant mechanical properties to circumvent significant implant plasticity and collapse under the loading conditions. Together, the experimental and finite element modeling results support an optimal porosity in the range of 60-70% for maximizing osseointegration with current structure and loading.


Asunto(s)
Análisis de Elementos Finitos , Ensayo de Materiales , Oseointegración , Porosidad , Prótesis e Implantes , Fenómenos Mecánicos , Animales , Metales/química , Estrés Mecánico
16.
Skeletal Radiol ; 53(6): 1033-1043, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38044373

RESUMEN

Osseointegrated implants have been developed to allow direct skeletal fixation of a prosthesis as an alternative to traditional socket-fitted prostheses for patients who have suffered from a major limb amputation. The implants contribute to improvements in functional outcome and quality of life and radiological evaluation plays a crucial role in pre- and post-operative assessment. This article acts as a guide for radiologists who may be tasked with providing the radiological information required by surgeons and prosthetists. We also look at the radiological appearances of complications that may arise in patients treated with an osseointegrated implant. Plain X-rays are used to screen patients who wish to undergo treatment. Limb-length X-rays are then used to measure the length of any residual bone, and comparisons can be made with the normal side (if present). From this, decisions about the likely size of the implant and the need for further amputation can be made. CT scans enable accurate assessment of the medullary cavity and cortical thickness. Post-operatively, plain X-rays form the mainstay of the routine monitoring of the bone-implant interface. Potential complications include infection, aseptic loosening, mechanical fracture of the implant and periprosthetic fracture. Infection and aseptic loosening can be seen as a lucency at the bone-implant interface which (if left untreated) can lead to loss of the implant. Implant and periprosthetic fractures are radiographically obvious. Radiologists involved in the care of patients undergoing treatment with an osseointegrated implant should become familiar with the imaging requirements so they can contribute to optimal patient outcomes.


Asunto(s)
Miembros Artificiales , Calidad de Vida , Humanos , Amputación Quirúrgica , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/métodos , Radiólogos , Resultado del Tratamiento , Diseño de Prótesis
17.
Lasers Med Sci ; 39(1): 162, 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38910231

RESUMEN

The review critically evaluates the current state of studies investigating laser irradiation for modifying titanium surfaces to enhance the biointegration of dental implants. Laser modification is a rapidly evolving physicochemical surface modification process with the potential to revolutionize dental implant technology. A thorough search of electronic databases, including PubMed, Science Direct, MEDLINE, and Web of Knowledge, was conducted to identify relevant articles. The review focuses on the surface features of laser-modified implants, encompassing in vitro cell culture experiments, rare animal experiments, and limited clinical trials. Of the 26 selected sources, 21 describe surface features, while only two involve in vivo human experiments. The review highlights the lack of long-term clinical experience and calls for further research to mature these technologies. Despite the absence of a consensus on optimal laser types and settings, the overall results are promising, with few negative outcomes. As research in laser irradiation of titanium surfaces progresses, significant advancements in dental implant technology and improved patient well-being are anticipated.


Asunto(s)
Implantes Dentales , Rayos Láser , Propiedades de Superficie , Titanio , Humanos , Animales , Oseointegración
18.
J Neuroeng Rehabil ; 21(1): 35, 2024 03 07.
Artículo en Inglés | MEDLINE | ID: mdl-38454427

RESUMEN

BACKGROUND: Persons with a transfemoral amputation (TFA) often experience difficulties in daily-life ambulation, including an asymmetrical and less stable gait pattern and a greater cognitive demand of walking. However, it remains unclear whether this is effected by the prosthetic suspension, as eliminating the non-rigid prosthetic connection may influence stability and cortical activity during walking. Spatiotemporal and stability-related gait parameters, as well as cortical activity during walking, were evaluated between highly active individuals (MFC-level K3-4) with a TFA and able-bodied (AB) persons, and between persons with a bone-anchored prosthesis (BAP) and those with a socket-suspended prosthesis (SSP). METHODS: 18 AB persons and 20 persons with a unilateral TFA (10 BAP-users, 10 SSP-users) walked on a treadmill at their preferred speed. Spatiotemporal and margin of stability parameters were extracted from three-dimensional movement recordings. In addition, 126-channel electroencephalogram (EEG) was recorded. Brain-related activity from several cortical areas was isolated using independent component analysis. Source-level data were divided into gait cycles and subjected to time-frequency analysis to determine gait-cycle dependent modulations of cortical activity. RESULTS: Persons with TFA walked with smaller and wider steps and with greater variability in mediolateral foot placement than AB subjects; no significant differences were found between BAP- and SSP-users. The EEG analysis yielded four cortical clusters in frontal, central (both hemispheres), and parietal areas. No statistically significant between-group differences were found in the mean power over the entire gait cycle. The event-related spectral perturbation maps revealed differences in power modulations (theta, alpha, and beta bands) between TFA and AB groups, and between BAP- and SSP-users, with largest differences observed around heel strike of either leg. CONCLUSIONS: The anticipated differences in gait parameters in persons with TFA were confirmed, however no significant effect of the fixed suspension of a BAP was found. The preliminary EEG findings may indicate more active monitoring and control of stability in persons with TFA, which appeared to be timed differently in SSP than in BAP-users. Future studies may focus on walking tasks that challenge stability to further investigate differences related to prosthetic suspension.


Asunto(s)
Amputados , Miembros Artificiales , Prótesis Anclada al Hueso , Humanos , Marcha , Amputación Quirúrgica , Caminata , Fenómenos Biomecánicos , Diseño de Prótesis
19.
J Neuroeng Rehabil ; 21(1): 128, 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39085954

RESUMEN

BACKGROUND: Systems that capture motion under laboratory conditions limit validity in real-world environments. Mobile motion capture solutions such as Inertial Measurement Units (IMUs) can progress our understanding of "real" human movement. IMU data must be validated in each application to interpret with clinical applicability; this is particularly true for diverse populations. Our IMU analysis method builds on the OpenSim IMU Inverse Kinematics toolkit integrating the Versatile Quaternion-based Filter and incorporates realistic constraints to the underlying biomechanical model. We validate our processing method against the reference standard optical motion capture in a case report with participants with transfemoral amputation fitted with a Percutaneous Osseointegrated Implant (POI) and without amputation walking over level ground. We hypothesis that by using this novel pipeline, we can validate IMU motion capture data, to a clinically acceptable degree. RESULTS: Average RMSE (across all joints) between the two systems from the participant with a unilateral transfemoral amputation (TFA) on the amputated and the intact sides were 2.35° (IQR = 1.45°) and 3.59° (IQR = 2.00°) respectively. Equivalent results in the non-amputated participant were 2.26° (IQR = 1.08°). Joint level average RMSE between the two systems from the TFA ranged from 1.66° to 3.82° and from 1.21° to 5.46° in the non-amputated participant. In plane average RMSE between the two systems from the TFA ranged from 2.17° (coronal) to 3.91° (sagittal) and from 1.96° (transverse) to 2.32° (sagittal) in the non-amputated participant. Coefficients of Multiple Correlation (CMC) results between the two systems in the TFA ranged from 0.74 to > 0.99 and from 0.72 to > 0.99 in the non-amputated participant and resulted in 'excellent' similarity in each data set average, in every plane and at all joint levels. Normalized RMSE between the two systems from the TFA ranged from 3.40% (knee level) to 54.54% (pelvis level) and from 2.18% to 36.01% in the non-amputated participant. CONCLUSIONS: We offer a modular processing pipeline that enables the addition of extra layers, facilitates changes to the underlying biomechanical model, and can accept raw IMU data from any vendor. We successfully validate the pipeline using data, for the first time, from a TFA participant using a POI and have proved our hypothesis.


Asunto(s)
Amputación Quirúrgica , Miembros Artificiales , Humanos , Fenómenos Biomecánicos , Amputación Quirúrgica/rehabilitación , Fémur/cirugía , Oseointegración/fisiología , Masculino , Prueba de Estudio Conceptual , Amputados/rehabilitación , Caminata/fisiología , Adulto , Prótesis Anclada al Hueso
20.
Artículo en Inglés | MEDLINE | ID: mdl-39126510

RESUMEN

INTRODUCTION: Bone anchored hearing implants (BAHI) are considered for conductive and mixed hearing loss, relying on osseointegration of a titanium implant. Limitations relate to constant skin contact, with resultant percutaneous infections and granulation. This study investigates whether patient characteristics and implant-specifications contribute to BAHIs' skin complications in a cohort with a uniform surgical approach. METHODS: A 10 year (2014-2024) retrospective cohort study was conducted on BAHI procedures that were undertaken using a tissue-preserving 'punch' technique. Data on patient demographics, co-morbidities, implant type, surgical approach, and complications were collected. Poisson regression analysis was used to identify predictors of complications. RESULTS: A total of 53 patients undergoing 55 BAHI surgeries by three ENT consultants were included. Factors that greatly increased implant-related percutaneous infections included the Cochlear™ BIA400 implant when compared to the Ponto™ BHX implant (twofold, CI 2.03-2.16), abutment sizes ≤ 10 mm (fourfold, CI 3.99-4.12) and male gender (9%, CI 1.07-1.12). Granulation episodes were affected by cardiovascular disease (CVD) status (1.5-fold, CI 0.26-0.78), BIA400 implant (threefold, CI 8.8.-9.2) and abutment sizes ≤ 10 mm (fourfold, CI 3.6-3.73). Revision surgery episodes increased with diabetic status (1.2-fold, CI 0.06-0.37) and abutment sizes ≤ 10 mm (threefold, 3.303-3.304). CONCLUSIONS: Larger cohort studies are required to confirm findings, particularly for implant and abutment size contributions. However, the findings suggest that using a larger abutment size when skin thickness meassuremets are borderline, improved hygiene education in male patients, pre-operative optimisation of CVD and diabetes, and adjusted patient follow-up based on risk stratification of the contributing factors to complication rates could reduce complication rates.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA