Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 82
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Nano Lett ; 24(3): 905-913, 2024 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-38197790

RESUMEN

Lead halide perovskite nanocrystals (LHP-NCs) embedded in polymeric hosts are gaining attention as scalable and low-cost scintillation detectors for technologically relevant applications. Despite rapid progress, little is currently known about the scintillation properties and stability of LHP-NCs prepared by the ligand assisted reprecipitation (LARP) method, which allows mass scalability at room temperature unmatched by any other type of nanostructure, and the implications of incorporating LHP-NCs into polyacrylate hosts are still largely debated. Here, we show that LARP-synthesized CsPbBr3 NCs are comparable to particles from hot-injection routes and unravel the dual effect of polyacrylate incorporation, where the partial degradation of LHP-NCs luminescence is counterbalanced by the passivation of electron-poor defects by the host acrylic groups. Experiments on NCs with tailored surface defects show that the balance between such antithetical effects of polymer embedding is determined by the surface defect density of the NCs and provide guidelines for further material optimization.

2.
Small ; 20(16): e2308242, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38016066

RESUMEN

The next-generation X-ray detectors require novel semiconductors with low material/fabrication cost, excellent X-ray response characteristics, and robust operational stability. The family of organic-inorganic hybrid perovskites (OIHPs) materials comprises a range of crystal configuration (i.e., films, wafers, and single crystals) with tunable chemical composition, structures, and electronic properties, which can perfectly meet the multiple-stringent requirements of high-energy radiation detection, making them emerging as the cutting-edge candidate for next-generation X-ray detectors. From the perspective of molecular dimensionality, the physicochemical and optoelectronic characteristics of OIHPs exhibit dimensionality-dependent behavior, and thus the structural dimensionality is recognized as the key factor that determines the device performance of OIHPs-based X-ray detectors. Nevertheless, the correlation between dimensionality of OIHPs and performance of their X-ray detectors is still short of theoretical guidance, which become a bottleneck that impedes the development of efficient X-ray detectors. In the review, the advanced studies on the dimensionality engineering of OIHPs are critically assessed in X-ray detection application, discussing the current understanding on the "dimensionality-property" relationship of OIHPs and the state-of-the-art progresses on the dimensionality-engineered OIHPs-based X-ray detector, and highlight the open challenges and future outlook of this field.

3.
Chemistry ; 30(17): e202303918, 2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38102982

RESUMEN

The photoluminescent properties of lanthanide complexes have been thoroughly investigated; however, there have been much fewer studies showcasing their potential use in ionizing radiation detection. In this work, we delve into the photo- and radio-induced luminescence of a series of lanthanide-bearing organic-inorganic hybrids and their potential as a platform for X-ray scintillation and imaging. The judicious synergy between lanthanide cations and 2,6-di(1H-pyrazol-1-yl)isonicotinate (bppCOO-) ligands affords six new materials with three distinct structures. Notably, Eu-bppCOO-1 and Tb-bppCOO-2 display sharp fingerprint X-ray-excited luminescence (XEL), the intensities of which can be linearly correlated with the X-ray dose rates over a broad dynamic range (0.007-4.55 mGy s-1). Moreover, the X-ray sensing efficacies of Eu-bppCOO-1 and Tb-bppCOO-2 were evaluated, showing that Tb-bppCOO-2 features a lower detection limit of 4.06 µGy s-1 compared to 14.55 µGy s-1 of Eu-bppCOO-1. Given the higher X-ray sensitivity and excellent radiation stability of Tb-bppCOO-2, we fabricated a flexible scintillator film for X-ray imaging by embedding finely ground Tb-bppCOO-2 in the polydimethylsiloxane (PDMS) polymer. The resulting scintillator film can be utilized for high-resolution X-ray imaging with a spatial resolution of approximately 7 lp mm-1.

4.
Chemphyschem ; : e202400149, 2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39015100

RESUMEN

The heavy metal selenophosphate Pb2P2Se6emerges as a promising room-temperature X-ray/γ-ray detectors due to its high resistivity, robust radiation-blocking capability, and outstanding carrier mobility-lifetime product, etc. However, the high activity of phosphides poses significant impediment to the synthesis and single crystal growth. In this work, we have prepared high-quality Pb2P2Se6 single crystals with using the chemical vapor transport (CVT) method. The XRD analysis combined with EDS result confirmed the uniform composition of the resulting as-grown single crystals, while UV-Vis-NIR transmittance spectra revealed the bandgap of 1.89 eV. Selected area electron diffraction patterns indicated the crystal belonged to the P21/c(14) space group. Additionally, the Au/Pb2P2Se6/Au device is fabricated, which exhibits a robust X-ray response with a sensitivity of 648.61 µC·Gy-1·cm-2 at 400 V·mm-1 under 50 kVp. Notably, the device also excels in alpha particle detection, boasting a resolution of ~14.48% under a bias of 400 V bias. The hole mobility-lifetime product (µτ)h of Pb2P2Se6 is estimated to be ~2.58×10-5 cm2·V-1. The results underscore potential applications of Pb2P2Se6 crystal is in the field of the semiconductor radiation detectors.

5.
J Fluoresc ; 2024 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-39300050

RESUMEN

This paper reports the results of a detailed study of the optical response of boron difluoride curcuminoids to radiation exposure. Two lines of the dyes fundamentally different in structure (namely, symmetrical and asymmetrical) were tested. If the absorption responses of their solutions in chloroform to X-rays turns out to be quite close quantitatively (note that it has a very indicative visual manifestation - a gradual discoloration is observed in the dose range up to 300 Gy), the fluorescence ones differ notably: among other things, the former demonstrate much more sensitive reactions (the corresponding limit of detection values ​​differ by up to 2.36-fold). Nevertheless, in both parameters, these dyes generally show good linearity of the response as in classical coordinates (up to ≈ 100-150 Gy), as in semi-logarithmic ones (up to 1000 Gy). Since the main reason for such behavior seems to be the radiation-induced decomposition of the dyes, its possible scheme and corresponding "weak links" in the structure of the molecules (in other words, radiosensitive elements) are proposed for each case. For example, these include N(CH3)2 fragments at the ends of dimethylaminostyryl groups. It is precisely their detachment that determines the observed optical response of asymmetrical dyes. Thus, the results obtained provide some insight into the possibilities of controlling the sensitivity of organic dyes to irradiation by changing their structure.

6.
Sensors (Basel) ; 24(9)2024 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-38733041

RESUMEN

Open Hardware-based microcontrollers, especially the Arduino platform, have become a comparably easy-to-use tool for rapid prototyping and implementing creative solutions. Such devices in combination with dedicated front-end electronics can offer low-cost alternatives for student projects, slow control and independently operating small-scale instrumentation. The capabilities can be extended to data taking and signal analysis at mid-level rates. Two detector realizations are presented, which cover the readouts of proportional counter tubes and of scintillators or wavelength-shifting fibers with silicon photomultipliers (SiPMs). The SiPMTrigger realizes a small-scale design for coincidence readout of SiPMs as a trigger or veto detector. It consists of a custom mixed signal front-end board featuring signal amplification, discrimination and a coincidence unit for rates of up to 200 kHz. The nCatcher transforms an Arduino Nano to a proportional counter readout with pulse shape analysis: time over threshold measurement and a 10-bit analog-to-digital converter for pulse heights. The device is suitable for low-to-medium-rate environments up to 5 kHz, where a good signal-to-noise ratio is crucial. We showcase the monitoring of thermal neutrons. For data taking and slow control, a logger board is presented that features an SD card and GSM/LoRa interface.

7.
Sensors (Basel) ; 24(12)2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38931565

RESUMEN

Heavy nuclides like uranium and their decay products are commonly found in nuclear industries and can pose a significant health risk to humans due to their alpha-emitting properties. Traditional alpha detectors require close contact with the contaminated surface, which can be time-consuming, labour-intensive, and put personnel at risk. Remote detection is urgently needed but very challenging. To this end, a candidate detection mechanism is alpha-induced radio-luminescence. This approach uses the emission of photons from radio-ionised excited nitrogen molecules to imply the presence of alpha emitters from a distance. Herein, the use of this phenomenon to remotely image various alpha emitters with unparalleled levels of sensitivity and spatial accuracy is demonstrated. Notably, the system detected a 29 kBq Am-241 source at a distance of 3 m within 10 min. Furthermore, it demonstrated the capability to discern a 29 kBq source positioned 7 cm away from a 3 MBq source at a 2 m distance. Additionally, a 'sandwich' filter structure is described that incorporates an absorptive filter between two interference filters to enhance the ambient light rejection. The testing of the system is described in different lighting environments, including room light and inside a glovebox. This method promises safer and more efficient alpha monitoring, with applications in nuclear forensics, waste management and decommissioning.

8.
Sensors (Basel) ; 24(16)2024 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-39205039

RESUMEN

Alpha emitters like plutonium pose severe health risks when ingested, damaging DNA and potentially causing cancer. Traditional detection methods require proximity within millimeters of the contamination source, presenting safety risks and operational inefficiencies. Long-range detection through alpha radioluminescence (RL) offers a promising alternative. However, most of the previous experiments have been carried out under controlled conditions that preclude the overwhelming effect of ambient light. This study demonstrates the successful detection of a 3 MBq alpha emitter in an open environment using a compact alpha camera. This camera incorporates a deep-cooled CCD and a low f-number lens system designed to minimize the blue shift effects of filters. Night-time imaging was achieved with a dual-filter system using a sandwich filter assembly centered at 337 nm and 343 nm for capturing alpha RL and subtracting background light, respectively. At night, the alpha source was detected from 1 m away within one minute, and the lowest detection limit can be calculated as 75 kBq. The system was also evaluated under simulated urban lighting conditions. For daytime imaging, a stack of tilted 276 nm short pass filters minimized sunlight interference, enabling the detection of the alpha source at 70 cm within 10 min under indirect sunlight. This research highlights the viability of long-range optical detection of alpha emitters for environmental monitoring in real-world settings.

9.
Environ Geochem Health ; 46(6): 181, 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38695964

RESUMEN

This study determined natural and artificial radionuclide concentrations to evaluate natural radioactivity and health risk levels of nine travertines in the Yaprakhisar and Balkayasi regions in Turkey. The samples coded B1-M, B2, B5, B7, B8, and B10 represent waste derived from the Yaprakhisar travertines, as well as samples T5-M, T12, and Z1 travertines derived from Balkayasi. The levels of natural and artificial radionuclide concentrations (232Th, 40K, and 137Cs) were measured using a high-purity germanium (HpGe) detector system. The travertine activity ranged from 2.09 to 12.07 Bq kg-1 for 232Th, 4.21 to 13.41 Bq kg-1 for 40K, and 0.42-3.26 Bq kg-1 for 137Cs. The results showed that the activity concentration values for 232Th, 40K, and 137Cs were coherent with the travertine analysis results in the UNSCEAR, 2000; 2008 publications. The values obtained were lower than the average values in the UNSEAR reports. The radiological hazard parameters calculated in this study were absorbed gamma dose rate (D), radium equivalent activity (Raeq), annual gonadal dose equivalent (AGDE), exposure dose (ER), total annual effective dose (AEDEtotal), excess lifetime cancer risk (ELCRtotal), gamma representative level (GRL), internal hazard index (Hin) and external hazard index (Hex).


Asunto(s)
Radioisótopos de Cesio , Radioisótopos de Potasio , Monitoreo de Radiación , Turquía , Monitoreo de Radiación/métodos , Radioisótopos de Potasio/análisis , Radioisótopos de Cesio/análisis , Torio/análisis , Contaminantes Radiactivos del Suelo/análisis , Radiación de Fondo , Humanos , Medición de Riesgo
10.
Small ; 19(10): e2206782, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36534835

RESUMEN

Monitoring and shielding of X-ray radiation are of paramount importance across diverse fields. However, they are frequently realized in separate protocols and a single material integrating both functions remained elusive. Herein, a hexanuclear cluster [Th6 (µ3 -OH)4 (µ3 -O)4 (H2 O)6 ](pba)6 (HCOO)6 (Th-pba-0D) incorporating high-Z thorium cations and 3-(pyridin-4-yl)benzoate ligands that can function as a brand-new dual-module platform for visible detection and efficient shielding of ionizing radiation is demonstrated. Th-pba-0D exhibits rather unique reversible radiochromism upon alternating X-ray and UV irradiation. Moreover, the millimeter scale crystal size of Th-pba-0D renders the penetration depth of X-ray visible to naked eye and leads to the unearthing of its high X-ray attenuation efficiency. Indeed, the shielding efficacy of Th-pba-0D is comparable to that of lead glass containing 40% PbO, and a Th-pba-0D pellet with a thickness of merely 1.2 mm can shield 99.73% X-ray (16 keV). These studies portend the possible utilization of thorium-bearing materials as a bifunctional platform for radiation detection and shielding.

11.
Sensors (Basel) ; 22(3)2022 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-35161824

RESUMEN

Since the Fukushima Daiichi Nuclear Power Plant accident in March 2011, the technology available for unmanned aerial vehicles (UAVs) for radiation monitoring has improved greatly. Remote access to radiation-contaminated areas not only eliminates unnecessary exposure of civilians or military personnel, but also allows workers to explore inaccessible places. Hazardous levels of radioactive contamination can be expected as a result of accidents in the nuclear power industry or as a result of the intentional release of radioactive materials for terrorist purposes (dirty bombs, building contamination, etc.). The possibility to detect, identify, and characterize radiation and nuclear material using mobile and remote sensing platforms is a common requirement in the radiation sensing community. The technology has applications in homeland security and law enforcement, customs and border protection, nuclear power plant safety and security, nuclear waste monitoring, environmental recovery, and the military. In this work, the authors have developed, implemented, and characterized a gamma-ray detection and spectroscopy system capable of operating on a UAV. The system was mainly developed using open-source software and affordable hardware components to reduce development and maintenance costs and provide satisfactory performance as a detection instrument. The designed platform can be used to perform mapping or localization tasks to improve the risk assessment process for first responders during the management of radiological and nuclear incidents. First, the design process of the system is described; the result of the characterization of the platform is then presented together with the use of the prototype installed on a UAV in an exercise simulating a radiological and nuclear contamination scenario.


Asunto(s)
Monitoreo de Radiación , Terrorismo , Humanos , Plantas de Energía Nuclear
12.
Sensors (Basel) ; 22(13)2022 Jun 23.
Artículo en Inglés | MEDLINE | ID: mdl-35808247

RESUMEN

In the framework of radioactive material handling, such as in radwaste sorting and segregation operations, the availability of a simple tool to quickly detect and locate gamma radiation spots can be quite convenient. Additional spectroscopic features, even with moderate energy resolutions, could provide a useful benefit. As a proof of principle for such a tool, we developed a gamma detector prototype featuring an array of 10 × 10 CsI(Tl) scintillators (1 × 1 × 1 cm3) providing readouts by means of a corresponding array of 6 × 6 mm2 silicon photo multipliers (SiPM). Such a detector table could be easily incorporated into a work desk for quick scanning of possibly radioactive objects. The proposed detector has a good counting efficiency and energy resolution, while the simulations and tests show interesting hot-spot localization capabilities.


Asunto(s)
Tomografía de Emisión de Positrones , Silicio , Rayos gamma , Diseño Interior y Mobiliario , Conteo por Cintilación , Análisis Espectral
13.
Sensors (Basel) ; 22(13)2022 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-35808311

RESUMEN

In this paper, we present a calculation method for the radiation response eigenvalue based on a monolithic active pixel sensor. By comparing the statistical eigenvalues of different regions of a pixel array in bright and dark environments, the linear relationship between the statistical eigenvalues obtained by different algorithms and the radiation dose rate was studied. Additionally, a dose rate characterization method based on the analysis of the eigenvalues of the MAPS response signal was proposed. The experimental results show that in the dark background environment, the eigenvalues had a good linear response in the region of any gray value in the range of 10-30. In the color images, due to the difference in the background gray values in adjacent color regions, the radiation response signal in dark regions was confused with the image information in bright regions, resulting in the loss of response signal and affecting the analysis results of the radiation response signal. For the low dose rate radiation field, as the radiation response signal was too weak and there was background dark noise, it was necessary to accumulate frame images to obtain a sufficient response signal. For the intense radiation field, the number of response events in a single image was very high, and only two consecutive frames of image data needed to be accumulated to meet the statistical requirements. The binarization method had a good characterization effect for the radiation at a low dose rate, and the binarization processing and the total gray value statistics of the response data at a high dose rate could better characterize the radiation dose rate. The calibration experiment results show that the binarization processing method can meet the requirements of using a MAPS for wide-range detection.


Asunto(s)
Algoritmos
14.
Sensors (Basel) ; 22(6)2022 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-35336450

RESUMEN

Herein, we report the γ-ray ionizing radiation response of a commercial monolithic active-pixel sensor (MAPS) camera under strong-dose-rate irradiation with an online detection and monitoring system for strong radiation conditions. We present the first results of the distribution of three types of MAPS camera and establish a linear relationship between the average response signal and radiation dose rate in the strong-dose-rate range. There is an obvious response signal in the video frames when the camera module parameters are set to automatic, but the linear response is very poor. However, the fixed image parameters are not good at adapting to the changes of the environment and affect the quality of the video frames. A dual module online radiation detection and monitoring probe was made to carry out effective video monitoring and radiation detection at the same time. The measurement results show that the dose rate detection error is less than 5% with a dose rate in the range of 60 to 425 Gy/h, and the visible light image does not have obvious distortion, deformation, or color shift due to the interference of the radiation response event and radiation damage. Hence, the system test results show that it can be used for online detection and monitoring in a strong radiation environment.


Asunto(s)
Rayos gamma
15.
Sensors (Basel) ; 22(19)2022 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-36236411

RESUMEN

In nuclear power plants, particle accelerators, and other nuclear facilities, measuring the level of ionising gamma radiation is critical for the safety and management of the operation and the environment's protection. However, in many cases, it is impossible to monitor ionising radiation directly at the required location continuously. This is typically either due to the lack of space to accommodate the entire dosimeter or in environments with high ionising radiation activity, electromagnetic radiation, and temperature, which significantly shorten electronics' lifetime. To allow for radiation measurement in such scenarios, we designed a fibre optic dosimeter that introduces an optical fibre link to deliver the scintillation radiation between the ionising radiation sensor and the detectors. The sensors can thus be placed in space-constrained and electronically hostile locations. We used silica optical fibres that withstand high radiation doses, high temperatures, and electromagnetic interference. We use a single photon counter and a photomultiplier to detect the transmitted scintillation radiation. We have shown that selected optical fibres, combined with different scintillation materials, are suitable for measuring gamma radiation levels in hundreds of kBq. We present the architecture of the dosimeter and its experimental characterisation with several combinations of optical fibres, detectors, and scintillation crystals.


Asunto(s)
Fibras Ópticas , Dosímetros de Radiación , Fenómenos Físicos , Radiometría , Conteo por Cintilación , Dióxido de Silicio
16.
Sensors (Basel) ; 23(1)2022 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-36616926

RESUMEN

In order to detect special nuclear materials and other radioactive materials in Security and Defense scenarios, normally, a combination of neutron and gamma-ray detection systems is used. In particular, to avoid illicit traffic of special nuclear materials and radioactive sources/materials, radiation portal monitors are placed at seaports to inspect shipping-container cargo. Despite their large volume (high efficiency), these detection systems are expensive, and therefore only a fraction of these containers are inspected. In this work, a novel mobile radiation detection system is presented, based on an EJ-200 plastic scintillator for the detection of gamma rays and beta particles, and a neutron detector EJ-426HD plastic scintillator (with 6Li) embedded in a compact and modular moderator. The use of silicon photomultipliers in both detectors presented advantages such as lightweight, compactness, and low power consumption. The developed detection system was integrated in a highly maneuverable multirotor. Monte Carlo simulations were validated by laboratory measurements and field tests were performed using real gamma-ray and neutron sources. The detection and localization within one meter was achieved using a maximum likelihood estimation algorithm for 137Cs sources (4 MBq), as well as the detection of 241Am-beryllium (1.45 GBq) source placed inside the shipping container.


Asunto(s)
Monitoreo de Radiación , Conteo por Cintilación , Rayos gamma , Neutrones , Plásticos
17.
Sensors (Basel) ; 21(6)2021 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-33801076

RESUMEN

Radiation detectors installed at major ports of entry are a key component of the overall strategy to protect countries from nuclear terrorism. While the goal of deploying these systems is to intercept special nuclear material as it enters the country, no detector system is foolproof. Mobile, distributed sensors have been proposed to detect nuclear materials in transit should portal monitors fail to prevent their entry in the first place. In large metropolitan areas, a mobile distributed sensor network could be deployed using vehicle platforms such as taxis, Ubers, and Lyfts, which are already connected to communications infrastructure. However, performance and coverage that could be achieved using a network of sensors mounted on commercial passenger vehicles has not been established. Here, we evaluate how a mobile sensor network could perform in New York City using a combination of radiation transport and geographic information systems. The geographic information system is used in conjunction with OpenStreetMap data to isolate roads and construct a grid over the streets. Vehicle paths are built using pickup and drop off data from Uber, and from the New York State Department of Transportation. The results show that the time to first detection increases with source velocity, decreases with the number of mobile detectors, and reaches a plateau that depends on the strength of the source.

18.
Sensors (Basel) ; 21(22)2021 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-34833829

RESUMEN

In order to verify the performance of a graphene-based space radiation detection sensor, the radiation detection principle based on two-dimensional graphene material was analyzed according to the band structure and electric field effect of graphene. The method of space radiation detection based on graphene was studied and then a new type of space radiation sensor samples with small volume, high resolution, and radiation-resistance was formed. Using protons and electrons, the electrical performance of GFET radiation sensor was verified. The designed graphene space radiation detection sensor is expected to be applied in the radiation environment monitoring of the space station and the moon, and can also achieve technological breakthroughs in pulsar navigation and other fields.

19.
Sensors (Basel) ; 21(4)2021 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-33557104

RESUMEN

In the last decade, the development of more compact and lightweight radiation detection systems led to their application in handheld and small unmanned systems, particularly air-based platforms. Examples of improvements are: the use of silicon photomultiplier-based scintillators, new scintillating crystals, compact dual-mode detectors (gamma/neutron), data fusion, mobile sensor networks, cooperative detection and search. Gamma cameras and dual-particle cameras are increasingly being used for source location. This study reviews and discusses the research advancements in the field of gamma-ray and neutron measurements using mobile radiation detection systems since the Fukushima nuclear accident. Four scenarios are considered: radiological and nuclear accidents and emergencies; illicit traffic of special nuclear materials and radioactive materials; nuclear, accelerator, targets, and irradiation facilities; and naturally occurring radioactive materials monitoring-related activities. The work presented in this paper aims to: compile and review information on the radiation detection systems, contextual sensors and platforms used for each scenario; assess their advantages and limitations, looking prospectively to new research and challenges in the field; and support the decision making of national radioprotection agencies and response teams in respect to adequate detection system for each scenario. For that, an extensive literature review was conducted.

20.
Angew Chem Int Ed Engl ; 60(18): 9886-9890, 2021 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-33590695

RESUMEN

We disclose the intrinsic semiconducting properties of one of the largest mixed-valent uranium clusters, [H3 O+ ][UV (UVI O2 )8 (µ3 -O)6 (PhCOO)2 (Py(CH2 O)2 )4 (DMF)4 ] (Ph=phenyl, Py=pyridyl, DMF=N,N-dimethylformamide) (1). Single-crystal X-ray crystallography demonstrates that UV center is stabilized within a tetraoxo core surrounded by eight uranyl(VI) pentagonal bipyramidal centers. The oxidation states of uranium are substantiated by spectroscopic data and magnetic susceptibility measurement. Electronic spectroscopy and theory corroborate that UV species serve as electron donors and thus facilitate 1 being a n-type semiconductor. With the largest effective atomic number among all reported radiation-detection semiconductor materials, charge transport properties and photoconductivity were investigated under X-ray excitation for 1: a large on-off ratio of 500 and considerable charge mobility lifetime product of 2.3×10-4  cm2 V-1 , as well as a high detection sensitivity of 23.4 µC Gyair -1 cm-2 .

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA