Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 146
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
J Hand Surg Am ; 48(5): 513.e1-513.e8, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-35181176

RESUMEN

PURPOSE: Although several classifications are used to assess radiographs following radial head arthroplasty (RHA), including the Popovic classification for radiolucency, the Chanlalit classification for stress shielding (SS), the Brooker classification for heterotopic ossification (HO), and the Broberg-Morrey classification for radiocapitellar arthritis, little is known about the reliability of these classification systems. The purpose of this study was to determine the interobserver and intraobserver reliability of these classifications. METHODS: Six orthopedic surgeons at various levels of training reviewed elbow radiographs of 20 patients who underwent RHA and classified them according to the Popovic, Chanlalit, Brooker, and Broberg-Morrey classifications for radiolucency, SS, HO, and RHA, respectively. Four weeks after initial review, radiographic reviews were repeated. Reliability was measured using the Fleiss kappa and the intraclass correlation coefficient. Agreement was interpreted as none (<0), slight (0.01-0.2), fair (0.21-0.4), moderate (0.41-0.6), substantial (0.61-0.8), and almost perfect (0.81-1) based on agreement among attending surgeons. RESULTS: Among fellowship-trained attending surgeons, interobserver reliability was slight for SS (Chanlalit) and the categorical interpretation of radiolucency (Popovic), fair for radiocapitellar arthritis (Broberg-Morrey) and HO (Brooker), and substantial for the ordinal interpretation of radiolucency (Popovic). Residents had a higher interobserver reliability than attending physicians when using the Brooker classification. Mean intraobserver reliability was fair for SS (Chanlalit) and the categorical interpretation of radiolucency (Popovic), moderate for HO (Brooker) and radiocapitellar arthritis (Broberg-Morrey), and almost perfect for the ordinal interpretation of radiolucency (Popovic). Trainees had higher intraobserver reliability than attending surgeons using the SS (Chanlalit) classification. CONCLUSIONS: The number of Popovic zones is reliable for communication between physicians, but caution should be taken with the Brooker, Chanlalit, Broberg-Morrey, and categorical interpretation of the Popovic classifications. All the classifications had better intraobserver than interobserver reliability. CLINICAL RELEVANCE: Reliability of classification systems for radiographic complications after RHA is less than substantial except the number of zones of radiolucency; therefore, caution is required when drawing conclusions based on these classifications.


Asunto(s)
Artritis , Osificación Heterotópica , Humanos , Reproducibilidad de los Resultados , Variaciones Dependientes del Observador , Radiografía , Artroplastia/efectos adversos , Artritis/diagnóstico por imagen , Artritis/cirugía , Artritis/complicaciones , Osificación Heterotópica/etiología
2.
J Arthroplasty ; 38(4): 691-699, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36272510

RESUMEN

BACKGROUND: Cementless total knee arthroplasty (TKA) is the subject of renewed interest. Previous concerns about survivorship have been addressed and there is an appeal in terms of biological fixation and surgical efficiency. However, even surgeon advocates have concerns about the risk of marked subsidence when using this technology in older patients at risk for osteoporosis. METHODS: This was a retrospective analysis of 1,000 consecutive fully cementless mobile bearing TKAs performed at a single institution on women over 75 years of age who had postoperative and 1-year x-rays. The primary outcome was the incidence of subsidence. RESULTS: There were three asymptomatic cases with definite subsidence and change in alignment. In a fourth symptomatic case, the femoral component subsided into varus and the tibia into valgus, thus maintaining alignment which facilitated nonoperative treatment in a 92-year-old. Overall, at 1 year, there were two- liner revisions for infection without recurrence. Five patients had further surgery, of which three were washouts and two were for periprosthetic fractures sustained postoperatively within 1 year. Seven patients had further anesthesia, of which five were manipulations and two were nonrecurrent closed reductions for spinouts. CONCLUSION: Cementless TKA did not have a high risk of subsidence in this at-risk population. In the hands of experienced surgeons, these procedures can be used safely irrespective of bone quality.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/efectos adversos , Estudios Retrospectivos , Prótesis de la Rodilla/efectos adversos , Tibia/cirugía , Radiografía , Reoperación , Resultado del Tratamiento
3.
Arch Orthop Trauma Surg ; 143(11): 6945-6954, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37428271

RESUMEN

INTRODUCTION: Comparison between fully hydroxyapatite (HA)-coated stems with differing geometry are lacking in the total hip arthroplasty (THA) literature. This study aimed to compare femoral canal fill, radiolucency formation, and 2-year implant survivorship between two commonly used, HA-coated stems. METHODS: All primary THAs performed with two fully HA-coated stems (Polar stem, Smith&Nephew, Memphis, TN and Corail stem, DePuy-Synthes, Warsaw, IN) with a minimum 2-year radiographic follow-up were identified. Radiographic measures of proximal femoral morphology based on the Dorr classification and femoral canal fill were analyzed. Radiolucent lines were identified by Gruen zone. Perioperative characteristics and 2-year survivorship were compared between stem types. RESULTS: A total of 233 patients were identified with 132 (56.7%) receiving the Polar stem (P) and 101 (43.3%) receiving the Corail stem (C). No differences were observed with respect to proximal femoral morphology. Femoral stem canal fill at the middle third of the stem was greater for P stem patients than for C stem patients (P stem; 0.80 ± 0.08 vs. C stem; 0.77 ± 0.08, p = 0.002), while femoral stem canal fill at the distal third of the stem and presence of subsidence were comparable between groups. A total of six and nine radiolucencies were observed in P stem and C stem patients, respectively. Revision rate at 2-year (P stem; 1.5% vs C stem; 0.0%, p = 0.51) and latest follow-up (P stem; 1.5% vs C stem; 1.0%, p = 0.72) did not differ between groups. CONCLUSION: Greater canal fill at the middle third of the stem was observed for the P stem compared to the C stem, however, both stems demonstrated robust and comparable freedom from revision at 2-year and latest follow-up, with low incidences of radiolucent line formation. Mid-term clinical and radiographic outcomes for these commonly used, fully HA-coated stems remain equally promising in THA despite variations in canal fill.

4.
BMC Oral Health ; 23(1): 289, 2023 05 13.
Artículo en Inglés | MEDLINE | ID: mdl-37179291

RESUMEN

BACKGROUND: This study aimed to evaluate periapical radiolucency of endodontically treated teeth before and after orthodontic treatment using cone-beam computed tomography (CBCT). METHODS: Patients who underwent orthodontic treatment at Wonkwang University Daejeon Dental Hospital between January 2009 and June 2022 were included based on the following criteria: root canal treatment, and availability of CBCT images taken before and after orthodontic treatment with an interval of > 1 year between both scans. Patients with primary teeth or orthodontic tooth extractions were excluded. The size of the periapical radiolucency (SPR) of the endodontically treated tooth was evaluated using CBCT. Pre-orthodontic treatment CBCT images and the latest post-orthodontic treatment CBCT images were analyzed. The selected teeth were further categorized based on the orthodontic duration, CBCT interval, the patient sex and age, the tooth type and position (maxilla or mandible), and quality of root canal obturation. Statistical analyses were performed to evaluate changes in SPR using the paired t-test and multiple regression analysis. RESULTS: In total, 115 teeth (37 anterior teeth, 22 premolars and 56 molars) from 61 patients (age, 14-54 years) were included, with 39 teeth from male patients and 76 teeth from female patients. The age was ranged between 14 and 54 years old, and mean age was 25.87 years old. The mean CBCT interval and orthodontic treatment period were 43.32 months and 36.84 months, respectively. Seventy-five teeth showed good obturation quality, 80 were not used as anchors during orthodontic treatment, and 71 were maxillary. The SPR size increased after orthodontic treatment for 56 teeth and decreased for 59 cases. The average change in SPR was -0.102 mm and the difference was not significant. Significant decrease of SPR were observed between female patients (p = 0.036) and maxillary teeth (p = 0.040). CONCLUSION: Orthodontic treatment had no significant impact on the changes in the SPR in endodontically treated teeth in most categories. However, there was a significant difference among females and the maxillary teeth. In both categories, the size of radiolucency decreased significantly.


Asunto(s)
Tomografía Computarizada de Haz Cónico Espiral , Diente no Vital , Humanos , Masculino , Femenino , Adulto , Adolescente , Adulto Joven , Persona de Mediana Edad , Diente no Vital/diagnóstico por imagen , Diente no Vital/terapia , Tratamiento del Conducto Radicular/métodos , Obturación del Conducto Radicular , Diente Premolar , Tomografía Computarizada de Haz Cónico/métodos , Cavidad Pulpar
5.
BMC Oral Health ; 23(1): 380, 2023 06 12.
Artículo en Inglés | MEDLINE | ID: mdl-37308850

RESUMEN

AIM: This study was performed to histologically evaluate peri-coronal tissues of partially impacted and erupted third molars that did not exhibit pathologic peri-coronal radiolucency. MATERIALS AND METHODS: Healthy patients with erupted or partially erupted (with part or all of the dental crown present in the oral cavity) mandibular third molars (classified as IA and IIA according to the Pell and Gregory classification) and vertically positioned (according to the Winter classification or erupted third molars) associated with peri coronal radiolucency of equal to or less than 2.5 mm. Associated with third molar surgery, tissue sampling from the distal area was performed, which was subjected to an anatomopathological examination to determine the histological nature. RESULTS: One hundred teeth (100 patients) were selected, and 100 specimens were analyzed. 53% of the sample were included in the non-pathological group and 47% showed pathological changes (fibrotic tissue (n 15), periodontal cyst-like (n 9), squamous epithelial metaplasia (4 cases), islands of odontogenic epithelial residues organized micro-cyst with keratocystic/ameloblastic appearance (4 cases), granulation tissue (n 8), giant cell tumour (n 4) and lobular capillary hemangioma (n 4)). Pathological changes did not have differences in incidence between the gender (p value = 0.85) and did not show any correlation with age, (p value = 0,96). CONCLUSIONS: These findings suggest that radiographic appearance may not be a reliable indicator of the absence of disease within a dental follicle. Therefore, clinicians should pay attention to or follow up on even peri-coronal radiolucency of less than 2.5 mm.


Asunto(s)
Tercer Molar , Diente Impactado , Humanos , Diente Molar , Boca , Estado de Salud
6.
J Contemp Dent Pract ; 24(10): 809-812, 2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-38152915

RESUMEN

AIM: To evaluate the cystic changes in the radiographically normal dental follicle associated with impacted mandibular third molar. MATERIALS AND METHODS: This study was conducted on 80 patients. Samples were selected using a convenient sampling technique from the patients who had impacted mandibular third molars in Pell and Gregory's positions B and C, with follicular space less than 2.5 mm in diameter. After surgical removal of an impacted tooth, the dental follicle was sent for histopathologic evaluation. RESULTS: Pathologic alterations were found in 19% of cases out of 80 samples. Odontogenic keratocystic and dentigerous cystic changes were found in 7% of cases. A statistically significant cystic alteration was found in female patients and distoangular impacted teeth. CONCLUSION: This study shows a significant cystic alteration in the radiologically normal dental follicles. Clinical and radiographic features alone may not be a reliable indicator of the absence of pathology. Early intervention of impacted teeth will help to reduce morbidity due to the development of pathology. CLINICAL SIGNIFICANCE: This study will help educate patients on the risks of retaining impacted teeth, based on scientific facts, in order to minimize the risks and to assess the correlation of pathologic alterations with the depth of impaction and angular position of the impacted tooth.


Asunto(s)
Tercer Molar , Diente Impactado , Humanos , Femenino , Tercer Molar/diagnóstico por imagen , Tercer Molar/patología , Diente Impactado/diagnóstico por imagen , Diente Impactado/cirugía , Saco Dental/patología , Diente Molar/patología , Mandíbula/patología
7.
Eur J Orthop Surg Traumatol ; 33(8): 3387-3393, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37133754

RESUMEN

BACKGROUND: This study aims to implement and assess the inter- and intra-reliability of a modernized radiolucency assessment system; the Radiolucency In cemented Stemmed Knee (RISK) arthroplasty classification. Furthermore, we assessed the distribution of regions affected by radiolucency in patients undergoing stemmed cemented total knee arthroplasty. METHODS: Stemmed total knee arthroplasty cases over 7-year period at a single institution were retrospectively identified and reviewed. The RISK classification system identifies five zones in the femur and five zones in the tibia in both the anteroposterior (AP) and lateral planes. Post-operative and follow-up radiographs were scored for radiolucency by four blinded reviewers at two distinct time points four weeks apart. Reliability was assessed using the kappa statistic. A heat map was generated to demonstrate the reported regions of radiolucency. RESULTS: 29 cases (63 radiographs) of stemmed total knee arthroplasty were examined radiographically using the RISK classification system. Intra-reliability (0.83) and Inter-reliability (0.80) scores were both consistent with a strong level of agreement using the kappa scoring system. Radiolucency was more commonly associated with the tibial component (76.6%) compared to the femoral component (23.3%), and the tibial anterior-posterior (AP) region 1 (medial plateau) was the most affected (14.9%). CONCLUSION: The RISK classification system is a reliable assessment tool for evaluating radiolucency around stemmed total knee arthroplasty using defined zones on both AP and lateral radiographs. Zones of radiolucency identified in this study may be relevant to implant survival and corresponded well with zones of fixation, which may help inform future research.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Estudios Retrospectivos , Reproducibilidad de los Resultados , Articulación de la Rodilla/cirugía , Tibia/diagnóstico por imagen , Tibia/cirugía
8.
J Shoulder Elbow Surg ; 31(12): 2554-2561, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35750156

RESUMEN

BACKGROUND: The primary purpose of this study was to compare 2-year anatomic total shoulder arthroplasty (TSA) functional and radiographic outcomes between Walch type A and B glenoids treated with an all-polyethylene glenoid designed for hybrid fixation with peripheral cement and central osseous integration. The secondary purpose was to evaluate outcomes based on central peg technique. The hypotheses were that there would be no difference in short-term radiographic or functional outcome scores based on preoperative glenoid morphology or central peg technique. METHODS: We performed a multicenter retrospective review of patients who underwent TSA with the same hybrid all-polyethylene glenoid and had minimum 2-year follow-up. Patient-reported outcomes and radiographic outcomes were analyzed based on preoperative Walch morphology and central peg technique. Radiographic analysis included preoperative glenoid morphology; preoperative and postoperative glenoid version, glenoid inclination, and posterior humeral head subluxation; and postoperative glenoid radiolucencies according to the Wirth and Lazarus classifications. RESULTS: A total of 266 patients with a mean age of 64.9 ± 8.2 years were evaluated at a mean of 28 months postoperatively. Postoperatively, there were significant improvements in all functional outcome measures (P < .001), range-of-motion measures (forward elevation, external rotation at 0°, external rotation at 90°, internal rotation by spinal level, and internal rotation at 90°; P < .001), and strength measures (Constant, external rotation, and modified belly press; P < .001). There were no clinically meaningful differences in functional outcomes or statistically significant differences in radiographic appearance between Walch type A and B glenoids. Subgroup analysis revealed that glenoids with a cemented central peg had the worst radiographic outcomes based on Lazarus scoring. CONCLUSION: Patients undergoing TSA with a hybrid in-line pegged glenoid have excellent clinical outcomes at short-term follow-up regardless of preoperative glenoid morphology. Different central peg techniques do not appear to play a significant role in the risk of glenoid component lucencies at 2 years postoperatively.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Cavidad Glenoidea , Articulación del Hombro , Anciano , Humanos , Persona de Mediana Edad , Artroplastía de Reemplazo de Hombro/métodos , Estudios de Seguimiento , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/cirugía , Polietileno , Diseño de Prótesis , Estudios Retrospectivos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Resultado del Tratamiento
9.
J Shoulder Elbow Surg ; 31(8): e386-e398, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35339705

RESUMEN

BACKGROUND: The rationale for advances in implant design is to improve performance in comparison to their predecessors. The purpose of this study was to compare a newer, self-pressurizing peripheral peg glenoid to a traditional polyethylene pegged glenoid through biomechanical evaluation and a retrospective radiographic and clinical review. METHODS: Three testing conditions (uncemented, partially cemented, and fully cemented) were chosen to assess the 2 component designs in a foam block model. The number of hammer hits to seat the component, amount of time to seat the component, and resistance-to-seat were collected. The implants were then cyclically loaded following ASTM F2028-17 testing standard. Clinically, postoperative radiographs of patients with a self-pressurized glenoid component (n = 225 patients) and traditional glenoid component (n = 206 patients) were evaluated for radiolucent lines and glenoid seating at various timepoints. Clinical outcomes (American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form, Simple Shoulder Test, and visual analog scale pain scores) and complications were recorded. The presence of radiolucent lines at the bone-cement interface was evaluated using the Modified Franklin Grade and the Lazarus grade. RESULTS: The self-pressurizing glenoid design required significantly more hammer hits than traditional glenoid designs in all groups tested (P < .029). Moreover, the self-pressurizing design had significantly more resistance-to-seat than traditional components in both the uncemented and partially cemented group (P < .002). No difference in resistance-to-seat was found between designs in the fully cemented group. The uncemented and partially cemented groups did not survive the full 50,000 cycles; however the self-pressurizing design had significantly less motion than the traditional design (P < .001). No differences between component designs were found in the fully cemented group at 50,000 cycles. The self-pressurizing glenoid component had 0.005% radiographic radiolucent lines, and the traditional glenoid component had 45% radiographic radiolucent lines, with 38% of the radiolucencies in the traditional glenoid component group being defined as grade E. There were no progressive radiolucencies, differences in clinical outcomes, or complications at 2 years postoperatively. CONCLUSION: In the fully cemented condition, the 2 component designs had comparable performance; however, the differences in designs could be better observed in the uncemented group. The self-pressurizing all-polyethylene design studied has superior biomechanical stability. Clinically, the improved stability of the glenoid component correlated with a reduction of radiolucent lines and will likely lead to a reduction in glenoid component loosening.


Asunto(s)
Cavidad Glenoidea , Articulación del Hombro , Estudios de Seguimiento , Humanos , Polietileno , Diseño de Prótesis , Falla de Prótesis , Estudios Retrospectivos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Resultado del Tratamiento
10.
J Shoulder Elbow Surg ; 31(5): 971-977, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34774775

RESUMEN

BACKGROUND: Trabecular Metal (TM)-backed glenoid implants were introduced for their theoretical ability to increase osseointegration while minimizing wear and the risk of loosening in total shoulder arthroplasty (TSA). Initial follow-up studies of TM-backed glenoids demonstrated high rates of metallic debris formation around the implant site, raising concerns about longevity. More recent data suggest that metallic debris formation may be less prevalent than previously reported and that the implants may have positive long-term outcomes regardless of debris. The goal of our study was to assess the clinical and radiographic outcomes at mid-term follow-up of TSA using a TM-backed glenoid implant placed with full backside support using an inset technique. We hypothesized that our clinical and radiographic outcomes would be good using this technique. METHODS: We retrospectively reviewed the charts of 39 patients who underwent 41 TSA procedures with a Zimmer Biomet TM-backed glenoid component performed by a single surgeon between January 2010 and March 2016. After exclusions for death unrelated to surgery and loss to follow-up, 35 patients (37 shoulders) with minimum 2-year clinical follow-up were included in the study. The glenoids were all placed in an inset fashion with full backside support. Clinical, patient-reported, and radiographic outcomes were analyzed. RESULTS: The average follow-up period was 7.2 years (range, 2-11 years). At final follow-up, average shoulder elevation was 153° ± 22° and average external rotation was 53° ± 12°. The average American Shoulder and Elbow Surgeons score was 86.8 ± 19.0, and the average visual analog scale score was 1.3 ± 2.4. Metallic debris was found in 9 shoulders (27%), and radiolucency was observed around the glenoid components in 13 shoulders (39%) on the final postoperative radiographs. Metallic debris and radiolucency findings were low in severity, with average grades of 0.32 (standard deviation, 0.54) and 0.39 (standard deviation, 0.50), respectively. There were no reoperations. CONCLUSION: This study of 37 shoulders undergoing TSA with a TM-backed glenoid demonstrated 100% implant survivorship at an average follow-up of 7 years. Clinical outcomes were excellent despite the occurrence of some metallic debris formation. The findings suggest that a TM-backed glenoid component implanted in an inset fashion to achieve full backside support can provide good clinical and patient-reported outcomes in TSA patients at mid-term follow-up and suggest that continued consideration of the role of TM-backed glenoids and the optimal technique for implantation may be warranted.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Cavidad Glenoidea , Articulación del Hombro , Prótesis de Hombro , Artroplastía de Reemplazo de Hombro/métodos , Estudios de Seguimiento , Cavidad Glenoidea/cirugía , Humanos , Metales , Diseño de Prótesis , Estudios Retrospectivos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Resultado del Tratamiento
11.
Int J Paediatr Dent ; 32(3): 428-435, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34672046

RESUMEN

BACKGROUND: Pre-eruptive intracoronal radiolucency (PEIR) poses a challenge to paediatric dentists as it cannot be clinically detected. AIM: To estimate the prevalence and coexisting factors of PEIR in permanent teeth of children and adolescents in western Tamil Nadu, India. DESIGN: This cross-sectional study assessed 5012 digital panoramic radiographs of children and adolescents below 14 years of age obtained from private digital imaging centers, dental clinics, and dental colleges located in five districts of western Tamil Nadu. The prevalence and PEIR and its coexisting factors were assessed by two independent calibrated investigators. Data were analyzed using the chi-square test. RESULTS: The subject prevalence and tooth prevalence of PEIR were estimated to be 3.2% and 0.4%, respectively. Maxillary canines and mandibular premolars were commonly involved. Majority of the lesions were limited to less than one-third of dentin thickness (74%) and distal aspect of the crown (45.1%). Ectopic positioning (9.3%) and dental caries in the preceding primary tooth (9.9%) were the most common coexisting factors. CONCLUSION: Pre-Eruptive Intracoronal Radiolucency defects were commonly seen in maxillary canines, mandibular premolars, and distal aspect of the crown involving less than one-third dentin thickness. Ectopic positioning and caries in primary teeth were commonly seen along with the PEIR defects.


Asunto(s)
Caries Dental , Diente no Erupcionado , Adolescente , Estudios Transversales , Caries Dental/epidemiología , Dentición Permanente , Humanos , India/epidemiología , Radiografía Panorámica , Diente no Erupcionado/diagnóstico por imagen , Diente no Erupcionado/epidemiología , Diente no Erupcionado/patología
12.
Gen Dent ; 70(5): 40-48, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35993932

RESUMEN

The objective of this case report and review of the literature is to address spontaneously regressing radiolucent lesions affecting the mandible. In 2010, a 16-year-old girl presented with an impacted mandibular third molar associated with a radiolucent lesion. At that time, the treating clinician considered the lesion to be at high risk of causing life-threatening bleeding. Therefore, it was suggested that she not have her tooth extracted. The patient was lost to follow-up for 8 years. Recent radiographs obtained by an oral and maxillofacial surgeon revealed that the lesion had resolved spontaneously. This article also reviews and summarizes cases in the literature in which radiolucent mandibular lesions regressed without treatment or with minimal intervention such as aspiration or incisional biopsy. The current case report and previously reported findings of spontaneous regression underscore the importance of establishing an accurate differential diagnosis and highlight the benefits of a multidisciplinary approach involving general dentists, oral and maxillofacial radiologists, pathologists, and surgical colleagues for management of mandibular radiolucencies.


Asunto(s)
Mandíbula , Diente Impactado , Adolescente , Femenino , Humanos , Mandíbula/cirugía , Diente Molar/patología , Diente Impactado/complicaciones
13.
Tohoku J Exp Med ; 253(4): 241-248, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33828023

RESUMEN

Dialysis-related amyloidosis (DRA) is characterized by the deposition of amyloid consisting of beta2-microglobulin in the musculoskeletal system, causing carpal tunnel syndrome, destructive spondyloarthropathy, and/or bone cysts. Increased cystic radiolucency of the bones and tendon thickening due to inflammation are common findings in DRA. We have developed a new dialysis method, extended-hours hemodialysis without dietary restrictions for the aim of improving both hypertension and malnutrition. We retrospectively evaluated the clinical effects of dialysis time on the risk for developing of DRA. The study subjects were all of the 30 patients who had received this treatment for more than 11 years. They were divided into two groups according to the weekly dialysis hours: 15 patients ≥ 16.5 hours/week (L-group) and 15 patients ≤ 15.5 hours/week (S-group). Plain x-ray imaging and ultrasonography were used to assess cystic radiolucency of the bones and thickness/diameter of the soft tissues. The proportion of the carpal bone cystic radiolucency was lower in the L-group. The severity of median nerve compression at the wrist was significantly less in the L-group (right hand: p = 0.0082, left hand: p = 0.0137). Multivariate regression analysis showed that dialysis time was a predictor of median nerve compression (ß = -0.559, p = 0.005). In conclusion, extended-hours hemodialysis without dietary restrictions contributes to lower the risk for developing of DRA at the wrist. We therefore propose that extended-hours hemodialysis without dietary restrictions is a preferred method which maintains the patients' quality of life compared with the conventional hemodialysis method.


Asunto(s)
Amiloidosis/etiología , Dietoterapia , Diálisis Renal/efectos adversos , Adulto , Amiloidosis/diagnóstico por imagen , Síndrome del Túnel Carpiano/diagnóstico por imagen , Femenino , Humanos , Modelos Logísticos , Masculino , Nervio Mediano/diagnóstico por imagen , Persona de Mediana Edad , Factores de Riesgo , Articulación del Hombro/diagnóstico por imagen , Espondiloartropatías/diagnóstico por imagen , Ultrasonografía
14.
J Arthroplasty ; 36(8): 2795-2800, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33810919

RESUMEN

BACKGROUND: High-flexion total knee arthroplasty (HF-TKA) prostheses were designed with hopes of improving knee function. Studies have suggested increased failure with HF-TKAs. The purpose is to compare clinical results of HF-TKA versus conventional TKA (C-TKA) from the same implant system with long-term follow-up. METHODS: This review of prostheses implanted between 2004 and 2007 matched 145 of 179 possible HF-TKAs with 145 of 1347 possible C-TKAs. Mean follow-up was 121.5 ± 20.3 months. We were unable to match 12 HF-TKAs. HF-TKAs with less than 8-year follow-up were excluded. The primary outcome was failure requiring revision. Secondary outcomes included range of motion (ROM), Knee Society Scores (KSS), and radiolucent lines. RESULTS: In the matched cohort, there were 15 HF-TKA reoperations, 8 of which involved component revisions. There were 12 reoperations in the C-TKA cohort but no component revisions (P = .001). The analysis of the unmatched cohorts revealed a higher revision rate for HF-TKAs (P = .039) (HF-TKA: 10/179 vs C-TKA: 27/1347). At final follow-up, HF-TKAs exhibited more prosthesis radiolucent lines without evidence of loosening. Particularly, HF-TKAs demonstrated more femoral zone IV radiolucencies (38.7%) at final follow-up compared with C-TKAs (13.8%) (P < .001). There were no differences found between cohorts in ROM or KSS. CONCLUSION: This study found an increased incidence of failure requiring revision with the HF-TKA in the matched and unmatched analyses. Higher incidences of radiolucent lines were found with HF-TKA. With no observed differences in ROM or KSS and a higher rate of failure with HF-TKA, there appears to be no advantage for use of the HF-TKA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Artroplastia de Reemplazo de Rodilla/efectos adversos , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Falla de Prótesis , Rango del Movimiento Articular , Estudios Retrospectivos , Resultado del Tratamiento
15.
BMC Oral Health ; 21(1): 428, 2021 09 05.
Artículo en Inglés | MEDLINE | ID: mdl-34482829

RESUMEN

BACKGROUND: Juxta-apical radiolucency (JAR) has been presented as a radiographic sign, suggestive of the IAN injury through third molar surgery. This study aimed to evaluate the relation of JAR with IAN injury in cone-beam computed tomography (CBCT) images and to determine whether the presence of JAR is related to tooth angulation, proximity to the mandibular canal, position to the IAN, and thinning of the cortical plates. METHODS: Of an initial sample of 545 mandibular third molars, a total of 75 JAR+ and 75 JAR- teeth were evaluated by CBCT. We assessed the relationship between the presence of JAR in cone-beam computed tomography (CBCT) images and the presence of IAN injury after mandibular third molar surgeries. Moreover, we investigated whether the presence of IAN injury is related to tooth angulation, proximity to the mandibular canal, position to the IAN, and thinning of the cortical plates. Descriptive statistics, Chi-square test, and Fisher's exact test were performed for statistical analysis. RESULTS: A significant relationship was found between JAR and temporary IAN injury (P = 0.036). However, there was no case of permanent IAN injury. IAN injury showed no significant relationship with the tooth angulation, position to IAN and proximity to the mandibular canal, lingual cortical plate thinning, sex, and age. CONCLUSIONS: JAR is generally in contact with the mandibular canal, and some degree of cortical thinning can be found in most cases. In this study, JAR was significantly related to temporary IAN injury. JAR may increase the risk of nerve injury during the surgical removal of third molars.


Asunto(s)
Tercer Molar , Diente Impactado , Humanos , Mandíbula/diagnóstico por imagen , Mandíbula/cirugía , Tercer Molar/diagnóstico por imagen , Tercer Molar/cirugía , Radiografía Panorámica , Estudios Retrospectivos , Diente Impactado/diagnóstico por imagen , Diente Impactado/cirugía
16.
J Shoulder Elbow Surg ; 29(11): 2292-2298, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32499196

RESUMEN

BACKGROUND: Glenoid component loosening remains an important concern in anatomic total shoulder arthroplasty. The aim of this study was to evaluate the clinical and radiographic results of a fully uncemented all-polyethylene fluted central peg bone-ingrowth glenoid component at a minimum 5-year follow-up. METHODS: Thirty-five shoulders in 31 patients (mean age, 73 years) with a mean follow-up of 100 months were retrospectively evaluated at an early and mid-term time point for Constant score (CS). Computed tomography visualized glenoid component fixation at both time points. RESULTS: Mean CS improved from 40 preoperatively to 66 postoperatively at latest follow-up (P < .001). A mean CS of 74 at early follow-up remained consistent with a mean CS of 66 at latest follow-up (P = .158), with only strength demonstrating a decrease over time (P < .001). An initial osseointegration rate of 81% at early follow-up decreased to 71% at latest follow-up with 74% of the shoulders demonstrating progressive radiolucent lines, resulting in a radiographic loosening rate of 31%. Of the 35 shoulders, 4 were revised (survival rate of 88%), of which 2 due to symptomatic aseptic loosening. CONCLUSIONS: Uncemented fixation of an all-polyethylene central peg bone-ingrowth glenoid was associated with satisfactory clinical and radiographic scores, and an acceptable revision rate at mid- to long-term follow-up. Despite initial bony osseointegration in the majority of cases, radiographic loosening over time remains a concern, potentially jeopardizing long-lasting fixation of this type of glenoid component when implanted in an off-label uncemented fashion.


Asunto(s)
Artroplastía de Reemplazo de Hombro/instrumentación , Artroplastía de Reemplazo de Hombro/métodos , Cavidad Glenoidea/cirugía , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/fisiopatología , Prótesis de Hombro , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Uso Fuera de lo Indicado , Oseointegración , Polietileno , Periodo Posoperatorio , Diseño de Prótesis , Falla de Prótesis , Radiografía , Reoperación , Estudios Retrospectivos , Articulación del Hombro/cirugía , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
17.
J Arthroplasty ; 35(2): 429-437, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31629621

RESUMEN

BACKGROUND: With the demand for arthroplasty increasing worldwide year on year, there is a drive to improve prosthesis longevity. Biological fixation from cementless implants has been one method of trying to achieve this. We hypothesized that the addition of a hydroxyapatite (HA) coating and 4 pegs to a porous-coated tibial tray would provide a reduction in time to implant osseointegration, allowing for normal physiological stress transfer, thus improving early postoperative pain and rehabilitation as well as the elimination of radiolucent lines (RLLs). METHODS: A prospective, randomized controlled single-blinded study was undertaken, comparing postoperative pain, radiographic evidence of biological fixation, and clinical outcomes between patients undergoing primary total knee arthroplasty with either LCS Complete POROCOAT (porous coating only) or LCS Complete DUOFIX (porous coating plus HA and pegs) knee systems (DePuy Synthes, Warsaw, IN). In total, 197 patients (205 knees) were recruited into the study between November 2006 and November 2008 and have been followed for up to 10 years. RESULTS: There were no clinically significant differences in pain or patient-reported outcome measures when comparing the 2 designs but the tibial tray with pegs and HA showed fewer RLLs at all time points. There was no correlation between RLLs and pain and no instances of loosening or osteolysis in either group. There was 1 revision for infection in the porous coating only group. CONCLUSION: The tray design with HA and additional fixation pegs did not confer any benefit in terms of reduced early postoperative pain or improved patient-reported outcomes, although it did result in significantly fewer RLLs. Both implants demonstrated excellent survivorship. With a cementless porous-coated tibial component, nonprogressive RLLs should be considered normal.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Artroplastia de Reemplazo de Rodilla/efectos adversos , Estudios de Seguimiento , Humanos , Prótesis de la Rodilla/efectos adversos , Dolor Postoperatorio/epidemiología , Dolor Postoperatorio/etiología , Dolor Postoperatorio/prevención & control , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis , Tibia/cirugía
18.
J Arthroplasty ; 35(1): 127-131, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31537374

RESUMEN

BACKGROUND: Aseptic loosening remains a common cause of failure in total knee arthroplasty (TKA). There is an increased interest in using uncemented TKA to reduce this complication. Radiolucencies (RLs) following uncemented TKA can be concerning. We report on the 9-year history of RLs in patients with uncemented TKA. METHODS: Twenty-one patients (26 knees) were treated with a cruciate-retaining fully porous coated femur/tibia and cemented patella. At final follow-up, 17 patients (22 knees) were available for review. Average follow-up was 9.6 years, average age was 59.1, and average body mass index was 34.1. X-rays were taken at 6 weeks, 1 year, and at final follow-up. RLs were measured using the Knee Society scoring system and read by two separate surgeons. RESULTS: At 6 weeks, we identified RL in all patients on both the tibia and femur. The majority were beneath the tibial tray and femoral chamfer. At 1 year, 4 femurs and 4 tibias showed new RLs (<2 mm) in similar zones. Eighteen femurs and 18 tibias showed fewer or no change in RLs. At final follow-up, no new tibia or femur developed a new RL. In total, 9 of the 22 tibias and 17 of the 22 femurs had remaining RLs, all less than 2 mm and none were progressive or new. Knee Society Score averaged 92.5 (6 weeks), 95.1 (1 year), and 97.3 (final). CONCLUSION: RLs are common following uncemented TKA. Many resolve by 1 year. There does not appear to be any association between the presence of RLs and long-term follow-up function in this group of patients.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Artroplastia de Reemplazo de Rodilla/efectos adversos , Cementos para Huesos , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla/efectos adversos , Persona de Mediana Edad , Falla de Prótesis , Reoperación , Tibia/diagnóstico por imagen , Tibia/cirugía , Resultado del Tratamiento
19.
Gerodontology ; 37(4): 411-415, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33179813

RESUMEN

OBJECTIVE: This report discusses the clinical relevance of a novel case of an odontoma and transmigrated canine in the setting of florid cemento-osseous dysplasia (COD), hypercementosis and moderate to severe periodontitis in a 66-year-old patient. BACKGROUND: An odontoma may infrequently impede tooth eruption and rarely has been implicated with canine transmigration. COD is a benign fibro-osseous lesion associated with decreased vascularity and poorer surgical intervention. MATERIALS AND METHODS: A partially edentulous woman, in no acute distress, underwent clinical and radiographic evaluation in pursuit of comprehensive dental care. RESULTS: Radiographic assessment demonstrated multiple occult pathologies of the mandible, including compound odontoma, canine transmigration, florid COD, hypercementosis and moderate to severe periodontitis, a concurrence thought to be previously unreported. Furthermore, the presence of the odontoma and transmigrated canine is apparently the second reported case in the geriatric population. CONCLUSIONS: The attending clinician should carefully weigh removal of an impacted and transmigrated canine associated with an odontoma in the setting of COD and compromised bone, particularly in older individuals. When surgical intervention is deferred in these clinical situations, patients should continue to be monitored for clinical and radiographic development of pathologic processes.


Asunto(s)
Displasia Fibrosa Ósea , Odontoma , Diente Impactado , Anciano , Diente Canino/diagnóstico por imagen , Femenino , Humanos , Mandíbula , Odontoma/complicaciones , Odontoma/diagnóstico por imagen , Odontoma/cirugía , Diente Impactado/diagnóstico por imagen , Diente Impactado/cirugía
20.
Int Endod J ; 52(9): 1264-1273, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30980723

RESUMEN

AIM: To (i) investigate the frequency and characteristics of pain and discomfort associated with root filled teeth in adult patients regularly attending the Public Dental Service in Örebro County, Sweden; (ii) assess the association between symptoms and clinical and radiographic findings; and (iii) explore the impact of pain and discomfort from root filled teeth on daily life. METHODOLOGY: Patient records of adult patients (≥20 years) scheduled for routine check-ups in April 2015 were screened to identify individuals with root filled teeth; all patients with ≥1 root filled tooth were asked to participate. The examination comprised of clinical and radiographic examinations and questionnaires on general health, on pain symptoms from root filled teeth and on the impact of pain on daily activities. In a general estimating equation (GEE), examination findings and patient-related factors were independently analysed in relation to the outcome 'presence of pain'. RESULTS: In total, 550 patients with 1256 root filled teeth participated. Fifty-three patients (9.6%) experienced pain or discomfort from 62 (4.9%) root filled teeth. Lower age, percussion tenderness and apical tenderness were significantly associated with pain (P > 0.001 to P = 0.044). The average pain intensity was 2.1 on a (0-10) Numeric Rating Scale, and average duration was 28.4 months. The impact on daily life was low. CONCLUSIONS: On average, pain associated with root filled teeth was of mild intensity, >2 years of duration and had low impact on daily life. Although the significantly associated clinical findings may indicate apical periodontitis as the most probable explanation in some teeth, the origin of pain from root filled teeth remains partly unexplained.


Asunto(s)
Periodontitis Periapical , Tratamiento del Conducto Radicular , Adulto , Humanos , Dolor , Obturación del Conducto Radicular , Suecia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA