Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.289
Filtrar
Más filtros

Intervalo de año de publicación
1.
N Engl J Med ; 389(13): 1180-1190, 2023 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-37754283

RESUMEN

BACKGROUND: Randomized, controlled trials have shown both benefit and harm from tight blood-glucose control in patients in the intensive care unit (ICU). Variation in the use of early parenteral nutrition and in insulin-induced severe hypoglycemia might explain this inconsistency. METHODS: We randomly assigned patients, on ICU admission, to liberal glucose control (insulin initiated only when the blood-glucose level was >215 mg per deciliter [>11.9 mmol per liter]) or to tight glucose control (blood-glucose level targeted with the use of the LOGIC-Insulin algorithm at 80 to 110 mg per deciliter [4.4 to 6.1 mmol per liter]); parenteral nutrition was withheld in both groups for 1 week. Protocol adherence was determined according to glucose metrics. The primary outcome was the length of time that ICU care was needed, calculated on the basis of time to discharge alive from the ICU, with death accounted for as a competing risk; 90-day mortality was the safety outcome. RESULTS: Of 9230 patients who underwent randomization, 4622 were assigned to liberal glucose control and 4608 to tight glucose control. The median morning blood-glucose level was 140 mg per deciliter (interquartile range, 122 to 161) with liberal glucose control and 107 mg per deciliter (interquartile range, 98 to 117) with tight glucose control. Severe hypoglycemia occurred in 31 patients (0.7%) in the liberal-control group and 47 patients (1.0%) in the tight-control group. The length of time that ICU care was needed was similar in the two groups (hazard ratio for earlier discharge alive with tight glucose control, 1.00; 95% confidence interval, 0.96 to 1.04; P = 0.94). Mortality at 90 days was also similar (10.1% with liberal glucose control and 10.5% with tight glucose control, P = 0.51). Analyses of eight prespecified secondary outcomes suggested that the incidence of new infections, the duration of respiratory and hemodynamic support, the time to discharge alive from the hospital, and mortality in the ICU and hospital were similar in the two groups, whereas severe acute kidney injury and cholestatic liver dysfunction appeared less prevalent with tight glucose control. CONCLUSIONS: In critically ill patients who were not receiving early parenteral nutrition, tight glucose control did not affect the length of time that ICU care was needed or mortality. (Funded by the Research Foundation-Flanders and others; TGC-Fast ClinicalTrials.gov number, NCT03665207.).


Asunto(s)
Glucemia , Enfermedad Crítica , Control Glucémico , Insulina , Humanos , Glucemia/análisis , Glucosa/análisis , Hipoglucemia/inducido químicamente , Insulina/administración & dosificación , Insulina/efectos adversos , Insulina/uso terapéutico , Unidades de Cuidados Intensivos , Control Glucémico/efectos adversos , Control Glucémico/métodos , Nutrición Parenteral , Algoritmos , Enfermedad Crítica/terapia
2.
N Engl J Med ; 389(4): 297-308, 2023 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-37356066

RESUMEN

BACKGROUND: Insulin icodec is an investigational once-weekly basal insulin analogue for diabetes management. METHODS: We conducted a 78-week randomized, open-label, treat-to-target phase 3a trial (including a 52-week main phase and a 26-week extension phase, plus a 5-week follow-up period) involving adults with type 2 diabetes (glycated hemoglobin level, 7 to 11%) who had not previously received insulin. Participants were randomly assigned in a 1:1 ratio to receive once-weekly insulin icodec or once-daily insulin glargine U100. The primary end point was the change in the glycated hemoglobin level from baseline to week 52; the confirmatory secondary end point was the percentage of time spent in the glycemic range of 70 to 180 mg per deciliter (3.9 to 10.0 mmol per liter) in weeks 48 to 52. Hypoglycemic episodes (from baseline to weeks 52 and 83) were recorded. RESULTS: Each group included 492 participants. Baseline characteristics were similar in the two groups. The mean reduction in the glycated hemoglobin level at 52 weeks was greater with icodec than with glargine U100 (from 8.50% to 6.93% with icodec [mean change, -1.55 percentage points] and from 8.44% to 7.12% with glargine U100 [mean change, -1.35 percentage points]); the estimated between-group difference (-0.19 percentage points; 95% confidence interval [CI], -0.36 to -0.03) confirmed the noninferiority (P<0.001) and superiority (P = 0.02) of icodec. The percentage of time spent in the glycemic range of 70 to 180 mg per deciliter was significantly higher with icodec than with glargine U100 (71.9% vs. 66.9%; estimated between-group difference, 4.27 percentage points [95% CI, 1.92 to 6.62]; P<0.001), which confirmed superiority. Rates of combined clinically significant or severe hypoglycemia were 0.30 events per person-year of exposure with icodec and 0.16 events per person-year of exposure with glargine U100 at week 52 (estimated rate ratio, 1.64; 95% CI, 0.98 to 2.75) and 0.30 and 0.16 events per person-year of exposure, respectively, at week 83 (estimated rate ratio, 1.63; 95% CI, 1.02 to 2.61). No new safety signals were identified, and incidences of adverse events were similar in the two groups. CONCLUSIONS: Glycemic control was significantly better with once-weekly insulin icodec than with once-daily insulin glargine U100. (Funded by Novo Nordisk; ONWARDS 1 ClinicalTrials.gov number, NCT04460885.).


Asunto(s)
Diabetes Mellitus Tipo 2 , Hipoglucemia , Hipoglucemiantes , Insulina Glargina , Insulina de Acción Prolongada , Adulto , Humanos , Glucemia/análisis , Diabetes Mellitus Tipo 2/sangre , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Hemoglobina Glucada/análisis , Hipoglucemia/sangre , Hipoglucemia/inducido químicamente , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/efectos adversos , Hipoglucemiantes/uso terapéutico , Insulina/efectos adversos , Insulina/análogos & derivados , Insulina Glargina/administración & dosificación , Insulina Glargina/efectos adversos , Insulina Glargina/uso terapéutico , Insulina de Acción Prolongada/administración & dosificación , Insulina de Acción Prolongada/efectos adversos , Insulina de Acción Prolongada/uso terapéutico , Estudios de Seguimiento , Esquema de Medicación
3.
N Engl J Med ; 388(11): 991-1001, 2023 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-36920756

RESUMEN

BACKGROUND: Closed-loop control systems of insulin delivery may improve glycemic outcomes in young children with type 1 diabetes. The efficacy and safety of initiating a closed-loop system virtually are unclear. METHODS: In this 13-week, multicenter trial, we randomly assigned, in a 2:1 ratio, children who were at least 2 years of age but younger than 6 years of age who had type 1 diabetes to receive treatment with a closed-loop system of insulin delivery or standard care that included either an insulin pump or multiple daily injections of insulin plus a continuous glucose monitor. The primary outcome was the percentage of time that the glucose level was in the target range of 70 to 180 mg per deciliter, as measured by continuous glucose monitoring. Secondary outcomes included the percentage of time that the glucose level was above 250 mg per deciliter or below 70 mg per deciliter, the mean glucose level, the glycated hemoglobin level, and safety outcomes. RESULTS: A total of 102 children underwent randomization (68 to the closed-loop group and 34 to the standard-care group); the glycated hemoglobin levels at baseline ranged from 5.2 to 11.5%. Initiation of the closed-loop system was virtual in 55 patients (81%). The mean (±SD) percentage of time that the glucose level was within the target range increased from 56.7±18.0% at baseline to 69.3±11.1% during the 13-week follow-up period in the closed-loop group and from 54.9±14.7% to 55.9±12.6% in the standard-care group (mean adjusted difference, 12.4 percentage points [equivalent to approximately 3 hours per day]; 95% confidence interval, 9.5 to 15.3; P<0.001). We observed similar treatment effects (favoring the closed-loop system) on the percentage of time that the glucose level was above 250 mg per deciliter, on the mean glucose level, and on the glycated hemoglobin level, with no significant between-group difference in the percentage of time that the glucose level was below 70 mg per deciliter. There were two cases of severe hypoglycemia in the closed-loop group and one case in the standard-care group. One case of diabetic ketoacidosis occurred in the closed-loop group. CONCLUSIONS: In this trial involving young children with type 1 diabetes, the glucose level was in the target range for a greater percentage of time with a closed-loop system than with standard care. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases; PEDAP ClinicalTrials.gov number, NCT04796779.).


Asunto(s)
Glucemia , Diabetes Mellitus Tipo 1 , Hipoglucemiantes , Sistemas de Infusión de Insulina , Insulina , Niño , Preescolar , Humanos , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hemoglobina Glucada/análisis , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/efectos adversos , Hipoglucemiantes/uso terapéutico , Insulina/administración & dosificación , Insulina/efectos adversos , Insulina/uso terapéutico , Sistemas de Infusión de Insulina/efectos adversos
4.
N Engl J Med ; 389(17): 1566-1578, 2023 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-37796241

RESUMEN

BACKGROUND: Hybrid closed-loop insulin therapy has shown promise for management of type 1 diabetes during pregnancy; however, its efficacy is unclear. METHODS: In this multicenter, controlled trial, we randomly assigned pregnant women with type 1 diabetes and a glycated hemoglobin level of at least 6.5% at nine sites in the United Kingdom to receive standard insulin therapy or hybrid closed-loop therapy, with both groups using continuous glucose monitoring. The primary outcome was the percentage of time in the pregnancy-specific target glucose range (63 to 140 mg per deciliter [3.5 to 7.8 mmol per liter]) as measured by continuous glucose monitoring from 16 weeks' gestation until delivery. Analyses were performed according to the intention-to-treat principle. Key secondary outcomes were the percentage of time spent in a hyperglycemic state (glucose level >140 mg per deciliter), overnight time in the target range, the glycated hemoglobin level, and safety events. RESULTS: A total of 124 participants with a mean (±SD) age of 31.1±5.3 years and a mean baseline glycated hemoglobin level of 7.7±1.2% underwent randomization. The mean percentage of time that the maternal glucose level was in the target range was 68.2±10.5% in the closed-loop group and 55.6±12.5% in the standard-care group (mean adjusted difference, 10.5 percentage points; 95% confidence interval [CI], 7.0 to 14.0; P<0.001). Results for the secondary outcomes were consistent with those of the primary outcome; participants in the closed-loop group spent less time in a hyperglycemic state than those in the standard-care group (difference, -10.2 percentage points; 95% CI, -13.8 to -6.6); had more overnight time in the target range (difference, 12.3 percentage points; 95% CI, 8.3 to 16.2), and had lower glycated hemoglobin levels (difference, -0.31 percentage points; 95% CI, -0.50 to -0.12). Little time was spent in a hypoglycemic state. No unanticipated safety problems associated with the use of closed-loop therapy during pregnancy occurred (6 instances of severe hypoglycemia, vs. 5 in the standard-care group; 1 instance of diabetic ketoacidosis in each group; and 12 device-related adverse events in the closed-loop group, 7 related to closed-loop therapy). CONCLUSIONS: Hybrid closed-loop therapy significantly improved maternal glycemic control during pregnancy complicated by type 1 diabetes. (Funded by the Efficacy and Mechanism Evaluation Program; AiDAPT ISRCTN Registry number, ISRCTN56898625.).


Asunto(s)
Glucemia , Diabetes Mellitus Tipo 1 , Hipoglucemiantes , Sistemas de Infusión de Insulina , Insulina , Embarazo en Diabéticas , Adulto , Femenino , Humanos , Embarazo , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/complicaciones , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hemoglobina Glucada/análisis , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/efectos adversos , Hipoglucemiantes/uso terapéutico , Insulina/administración & dosificación , Insulina/efectos adversos , Insulina/uso terapéutico , Sistemas de Infusión de Insulina/efectos adversos , Embarazo en Diabéticas/sangre , Embarazo en Diabéticas/tratamiento farmacológico , Resultado del Tratamiento
5.
N Engl J Med ; 387(13): 1161-1172, 2022 09 29.
Artículo en Inglés | MEDLINE | ID: mdl-36170500

RESUMEN

BACKGROUND: Currently available semiautomated insulin-delivery systems require individualized insulin regimens for the initialization of therapy and meal doses based on carbohydrate counting for routine operation. In contrast, the bionic pancreas is initialized only on the basis of body weight, makes all dose decisions and delivers insulin autonomously, and uses meal announcements without carbohydrate counting. METHODS: In this 13-week, multicenter, randomized trial, we randomly assigned in a 2:1 ratio persons at least 6 years of age with type 1 diabetes either to receive bionic pancreas treatment with insulin aspart or insulin lispro or to receive standard care (defined as any insulin-delivery method with unblinded, real-time continuous glucose monitoring). The primary outcome was the glycated hemoglobin level at 13 weeks. The key secondary outcome was the percentage of time that the glucose level as assessed by continuous glucose monitoring was below 54 mg per deciliter; the prespecified noninferiority limit for this outcome was 1 percentage point. Safety was also assessed. RESULTS: A total of 219 participants 6 to 79 years of age were assigned to the bionic-pancreas group, and 107 to the standard-care group. The glycated hemoglobin level decreased from 7.9% to 7.3% in the bionic-pancreas group and did not change (was at 7.7% at both time points) in the standard-care group (mean adjusted difference at 13 weeks, -0.5 percentage points; 95% confidence interval [CI], -0.6 to -0.3; P<0.001). The percentage of time that the glucose level as assessed by continuous glucose monitoring was below 54 mg per deciliter did not differ significantly between the two groups (13-week adjusted difference, 0.0 percentage points; 95% CI, -0.1 to 0.04; P<0.001 for noninferiority). The rate of severe hypoglycemia was 17.7 events per 100 participant-years in the bionic-pancreas group and 10.8 events per 100 participant-years in the standard-care group (P = 0.39). No episodes of diabetic ketoacidosis occurred in either group. CONCLUSIONS: In this 13-week, randomized trial involving adults and children with type 1 diabetes, use of a bionic pancreas was associated with a greater reduction than standard care in the glycated hemoglobin level. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases and others; ClinicalTrials.gov number, NCT04200313.).


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemiantes , Insulina Aspart , Sistemas de Infusión de Insulina , Insulina Lispro , Adolescente , Adulto , Anciano , Biónica/instrumentación , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea/instrumentación , Automonitorización de la Glucosa Sanguínea/métodos , Niño , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hemoglobina Glucada/análisis , Humanos , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/efectos adversos , Hipoglucemiantes/uso terapéutico , Insulina/administración & dosificación , Insulina/efectos adversos , Insulina/uso terapéutico , Insulina Aspart/administración & dosificación , Insulina Aspart/efectos adversos , Insulina Aspart/uso terapéutico , Sistemas de Infusión de Insulina/efectos adversos , Insulina Lispro/administración & dosificación , Insulina Lispro/efectos adversos , Insulina Lispro/uso terapéutico , Persona de Mediana Edad , Adulto Joven
6.
Ann Intern Med ; 177(7): 862-870, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38885505

RESUMEN

BACKGROUND: Metformin is a first-line pharmacotherapy for type 2 diabetes, but there is limited evidence about its safety in early pregnancy. OBJECTIVE: To evaluate the teratogenicity of metformin use in the first trimester of pregnancy. DESIGN: In an observational cohort of pregnant women with pregestational type 2 diabetes receiving metformin monotherapy before the last menstrual period (LMP), a target trial with 2 treatment strategies was emulated: insulin monotherapy (discontinue metformin treatment and initiate insulin within 90 days of LMP) or insulin plus metformin (continue metformin and initiate insulin within 90 days of LMP). SETTING: U.S. Medicaid health care administration database (2000 to 2018). PARTICIPANTS: 12 489 pregnant women who met the eligibility criteria. MEASUREMENTS: The risk and risk ratio of nonlive births, live births with congenital malformations, and congenital malformations among live births were estimated using standardization to adjust for covariates. RESULTS: A total of 850 women were in the insulin monotherapy group and 1557 in the insulin plus metformin group. The estimated risk for nonlive birth was 32.7% under insulin monotherapy (reference) and 34.3% under insulin plus metformin (risk ratio, 1.02 [95% CI, 1.01 to 1.04]). The estimated risk for live birth with congenital malformations was 8.0% (CI, 5.7% to 10.2%) under insulin monotherapy and 5.7% (CI, 4.5% to 7.3%) under insulin plus metformin (risk ratio, 0.72 [CI, 0.51 to 1.09]). LIMITATION: Possible residual confounding by glycemic control and body mass index. CONCLUSION: Compared with switching to insulin monotherapy, continuing metformin and adding insulin in early pregnancy resulted in little to no increased risk for nonlive birth among women receiving metformin before pregnancy. Under conventional statistical criteria, anything between a 49% decrease and a 9% increase in risk for congenital malformations was highly compatible with our data. PRIMARY FUNDING SOURCE: National Institutes of Health.


Asunto(s)
Anomalías Inducidas por Medicamentos , Diabetes Mellitus Tipo 2 , Hipoglucemiantes , Insulina , Metformina , Primer Trimestre del Embarazo , Embarazo en Diabéticas , Humanos , Metformina/efectos adversos , Metformina/uso terapéutico , Femenino , Embarazo , Hipoglucemiantes/efectos adversos , Hipoglucemiantes/uso terapéutico , Adulto , Anomalías Inducidas por Medicamentos/epidemiología , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Insulina/efectos adversos , Insulina/uso terapéutico , Embarazo en Diabéticas/tratamiento farmacológico , Quimioterapia Combinada , Estados Unidos , Factores de Riesgo
7.
J Gen Intern Med ; 39(13): 2400-2406, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38767746

RESUMEN

BACKGROUND: Severe hypoglycemia is a serious adverse drug event associated with hypoglycemia-prone medications; older patients with diabetes are particularly at high risk. Economic food insecurity (food insecurity due to financial limitations) is a known risk factor for hypoglycemia; however, less is known about physical food insecurity (due to difficulty cooking or shopping for food), which may increase with age, and its association with hypoglycemia. OBJECTIVE: Study associations between food insecurity and severe hypoglycemia. DESIGN: Survey based cross-sectional study. PARTICIPANTS: Survey responses were collected in 2019 from 1,164 older (≥ 65 years) patients with type 2 diabetes treated with insulin or sulfonylureas. MAIN MEASURES: Risk ratios (RR) for economic and physical food insecurity associated with self-reported severe hypoglycemia (low blood glucose requiring assistance) adjusted for age, financial strain, HbA1c, Charlson comorbidity score and frailty. Self-reported reasons for hypoglycemia endorsed by respondents. KEY RESULTS: Food insecurity was reported by 12.3% of the respondents; of whom 38.4% reported economic food insecurity only, 21.1% physical food insecurity only and 40.5% both. Economic food insecurity and physical food insecurity were strongly associated with severe hypoglycemia (RR = 4.3; p = 0.02 and RR = 4.4; p = 0.002, respectively). Missed meals ("skipped meals, not eating enough or waiting too long to eat") was the dominant reason (77.5%) given for hypoglycemia. CONCLUSIONS: Hypoglycemia prevention efforts among older patients with diabetes using hypoglycemia-prone medications should address food insecurity. Standard food insecurity questions, which are used to identify economic food insecurity, will fail to identify patients who have physical food insecurity only.


Asunto(s)
Diabetes Mellitus Tipo 2 , Inseguridad Alimentaria , Hipoglucemia , Hipoglucemiantes , Insulina , Compuestos de Sulfonilurea , Humanos , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 2/epidemiología , Hipoglucemia/inducido químicamente , Hipoglucemia/epidemiología , Masculino , Anciano , Femenino , Compuestos de Sulfonilurea/efectos adversos , Compuestos de Sulfonilurea/uso terapéutico , Estudios Transversales , Hipoglucemiantes/efectos adversos , Hipoglucemiantes/uso terapéutico , Hipoglucemiantes/economía , Insulina/uso terapéutico , Insulina/efectos adversos , Anciano de 80 o más Años , Factores de Riesgo
8.
J Gen Intern Med ; 39(10): 1895-1900, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38587726

RESUMEN

BACKGROUND: Inpatient use of insulin pump therapy has been increasing due to greater availability of this technology, however there is a paucity of research that investigates glycemic control of inpatient insulin pump users. OBJECTIVE: To compare the glycemic control of hospitalized patients with type 1 diabetes (T1D) who used insulin pump vs. multiple daily injections (MDI). DESIGN: Retrospective chart review. PARTICIPANTS: Patients with T1D who were hospitalized between January 1, 2017, and December 31, 2019, in an academic medical center in the New York metropolitan area. MAIN MEASURES: Patients were categorized into three groups based on their method of insulin administration: "pump only" group used insulin pump exclusively, "MDI only" group used MDI only, and "intermittent pump" group used a combination of both methods. The primary endpoints are mean blood glucose, rates of hypoglycemic events (blood glucose < 70 mg/dL), and rates of hyperglycemic events (blood glucose > 250 mg/dL). Separate multivariable Poisson regressions were performed to determine the association between the type of insulin administration and rate outcomes (i.e., rate of hypoglycemic events and rate of hyperglycemic events). RESULTS: The study included 78 patients with a mean age of 51, who were mostly male (54%), and white (72%). The average proportion of glucose measurements that were hyperglycemic for the "pump only", "MDI only", and "intermittent pump" groups were 0.11 (SD = 0.11), 0.25 (SD = 0.19), and 0.24 (SD = 0.25), respectively. The "pump only" group has a significantly lower proportion of hyperglycemic events as compared to the "MDI only" group (p = 0.0227). CONCLUSIONS: In this sample, patients who exclusively used their insulin pump while inpatient had a lower rate of hyperglycemic events than patients who used MDI only; suggesting that select patients can safely continue their insulin pump therapy in the inpatient setting.


Asunto(s)
Glucemia , Diabetes Mellitus Tipo 1 , Control Glucémico , Hipoglucemiantes , Sistemas de Infusión de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Masculino , Femenino , Insulina/administración & dosificación , Insulina/efectos adversos , Estudios Retrospectivos , Persona de Mediana Edad , Inyecciones Subcutáneas , Adulto , Hipoglucemiantes/administración & dosificación , Control Glucémico/métodos , Glucemia/efectos de los fármacos , Glucemia/análisis , Pacientes Internos , Hipoglucemia/inducido químicamente , Hipoglucemia/epidemiología , Anciano , Hospitalización
9.
Diabet Med ; 41(2): e15262, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38017692

RESUMEN

AIMS: Bespoke glycaemic control strategies following antenatal corticosteroids for women with diabetes in pregnancy (DIP) may mitigate hyperglycaemia. This study aims to identify predictive factors for the glycaemic response to betamethasone in a large cohort of women with DIP. METHODS: Evaluation of a prospective cohort study of 347 consecutive DIP pregnancies receiving two doses of 11.4 mg betamethasone 24 h apart between 2017 and 2021 and treated with the Pregnancy-IVI intravenous insulin protocol. Regression modelling identified factors associated with maternal glycaemic time-in-range (TIR) and maternal insulin requirements following betamethasone. Factors associated with neonatal hypoglycaemia (glucose <2.6 mmol/L) in infants born within 48 h of betamethasone administration (n = 144) were investigated. RESULTS: The mean maternal age was 31.9 ± 5.8 years, with gestational age at betamethasone of 33.5 ± 3.4 weeks. Gestational diabetes was present in 81% (12% type 1; 7% type 2). Pre-admission subcutaneous insulin was prescribed for 63%. On-infusion maternal glucose TIR (4.0-7.8 mmol/L) was 83% [IQR 77%-90%] and mean on-IVI glucose was 6.6 ± 0.5 mmol/L. Maternal hypoglycaemia (<3.8 mmol/L) was uncommon (0.47 h/100 on-IVI woman hours). Maternal glucose TIR was negatively associated with indicators of insulin resistance (type 2 diabetes, polycystic ovary syndrome), late-pregnancy complications (pre-eclampsia, chorioamnionitis) and the 1-h OGTT result. Intravenous insulin requirements were associated with type of diabetes, pre-eclampsia and intrauterine infection, the 1-h OGTT result and the timing of betamethasone administration. Neonatal hypoglycaemia was associated with pre-existing diabetes but not with measures of glycaemic control. CONCLUSION: An intravenous infusion protocol effectively controls maternal glucose after betamethasone. A risk-factor-based approach may allow individualisation of therapy.


Asunto(s)
Diabetes Mellitus Tipo 2 , Diabetes Gestacional , Enfermedades Fetales , Hiperglucemia , Hipoglucemia , Preeclampsia , Embarazo en Diabéticas , Recién Nacido , Embarazo , Femenino , Humanos , Adulto , Lactante , Diabetes Gestacional/tratamiento farmacológico , Diabetes Gestacional/epidemiología , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Betametasona/uso terapéutico , Hiperglucemia/prevención & control , Estudios Prospectivos , Hipoglucemia/inducido químicamente , Hipoglucemia/epidemiología , Hipoglucemia/prevención & control , Embarazo en Diabéticas/tratamiento farmacológico , Parto , Insulina/efectos adversos , Glucosa
10.
Diabet Med ; 41(7): e15339, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38679910

RESUMEN

AIM: To summarise, in a narrative review, published data on hypoglycaemia occurrence with basal insulin therapy in adults with type 1 diabetes treated with basal-bolus insulin regimens in treat-to-target randomised controlled trials. METHODS: Data were included from 21 eligible trials, which mainly used self-measured blood glucose or plasma glucose to detect hypoglycaemia. RESULTS: All-day self-measured blood glucose or plasma glucose level 2 (glucose threshold of 3.1 or 3.0 mmol/L) and level 3 (severe, requiring assistance) hypoglycaemic events were reported, respectively, by a range of 69.0%-97.5% and 0%-13.4% adults when receiving basal-bolus insulin therapy, with rates of 10.6-68.1 and 0.0-0.4 events per patient-year of exposure, respectively. Hypoglycaemia rates measured using continuous glucose monitoring (three studies) were numerically, yet consistently, higher than with either other method, except when limiting to symptomatic events. Nocturnal hypoglycaemia rates were generally less than 30% of the equivalent all-day rates. CONCLUSIONS: Differences across the studies in design (e.g., titration targets) and participant characteristics hindered comparison of hypoglycaemia rates by insulin formulation. Consequently, few trends were identified by insulin formulation, study methodology or individuals' characteristics, suggesting that further research is required to identify treatment strategies that facilitate development of individualised recommendations to lower hypoglycaemia risk. These findings are useful to understand hypoglycaemia risk with available basal insulin therapies when used in a multiple daily injection regimen, as well as to provide context for the results of ongoing and future clinical trials, including those for two once-weekly basal insulins, insulin icodec and basal insulin Fc.


Asunto(s)
Glucemia , Diabetes Mellitus Tipo 1 , Hipoglucemia , Hipoglucemiantes , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Hipoglucemia/inducido químicamente , Hipoglucemia/epidemiología , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/efectos adversos , Hipoglucemiantes/uso terapéutico , Insulina/administración & dosificación , Insulina/efectos adversos , Insulina/uso terapéutico , Glucemia/metabolismo , Glucemia/análisis , Ensayos Clínicos Controlados Aleatorios como Asunto , Adulto , Automonitorización de la Glucosa Sanguínea
11.
Diabetes Obes Metab ; 26(2): 512-523, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37857573

RESUMEN

AIM: Despite global recommendations for type 2 diabetes mellitus treatment to maintain optimal glycaemic targets, a significant proportion of people remain in suboptimal glycaemic control. Our objective was to investigate the impact of intensification delay after basal insulin (BI) initiation on long-term complications in people with suboptimal glycaemia. MATERIALS AND METHODS: We conducted a retrospective cohort study in individuals with type 2 diabetes mellitus initiated on BI. Those with suboptimal glycaemia (glycated haemoglobin ≥7% or ≥53 mmol/mol) within 12 months of BI initiation were divided into early (treatment intensified within 5 years), or late (≥5 years) intensification groups. We estimated the age-stratified risks of micro- and macrovascular complications among these groups compared with those with optimal glycaemia (glycated haemoglobin <7%). RESULTS: Of the 13 916 people with suboptimal glycaemia, 52.5% (n = 7304) did not receive any treatment intensification. In those aged <65 years, compared with the optimal glycaemia group late intensification was associated with a 56% higher risk of macrovascular complications (adjusted hazard ratio 1.56; 95% confidence intervals 1.08, 2.26). In elderly people (≥65 years), late intensification was associated with a higher risk of cardiovascular-related death (1.62; 1.03, 2.54) and a lower risk of microvascular complications (0.26; 0.08, 0.83). CONCLUSIONS: Those who had late intensification were at an increased risk of cardiovascular death if they were ≥65 years and an increased risk of macrovascular complications if they were <65 years. These findings highlight the critical need for earlier intensification of treatment and adopting personalized treatment strategies to improve patient outcomes.


Asunto(s)
Diabetes Mellitus Tipo 2 , Insulinas , Anciano , Humanos , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Hipoglucemiantes/efectos adversos , Hemoglobina Glucada , Estudios Retrospectivos , Tiempo de Tratamiento , Insulina/efectos adversos
12.
Diabetes Obes Metab ; 26(3): 1069-1081, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38192022

RESUMEN

AIM: Insulin icodec is a novel ultra-long action basal insulin analogue designed for once-weekly administration. With the merit of once-a-week administration, it promises better adherence and greater treatment satisfaction because of reduced injection frequency. The purpose of this study was to ascertain the efficacy and safety of once-weekly insulin icodec in comparison with other basal insulin analogues in the management of type 2 diabetes. MATERIALS AND METHODS: The PRISMA guidelines were followed during the conduct of this study. For the eligible studies, five databases and ClinicalTrials.gov were screened until July 2023. All randomized controlled trials comparing the efficacy and safety of insulin icodec in type 2 diabetes versus other insulin analogues were included. The extracted data were then analysed for meta-analysis using RevMan 5.3 software. RESULTS: Five clinical trials with 3764 participants were included. The meta-analysis showed that once-weekly insulin icodec had higher glycated haemoglobin (HbA1c) reduction [mean difference -0.17%, 95% confidence interval (CI; -0.28 to -0.06), p = .003], with no significant difference in fasting plasma glucose compared with other insulin analogues. HbA1c achievement <7% [odds ratio 1.51, 95% CI (1.14-1.99), p = .004] and HbA1c achievement <7% without hypoglycaemia [odds ratio 1.45, 95% CI (1.26-1.67), p < .00001] were observed in higher proportions with insulin icodec compared with the comparator group. The percentage of time spent in the target glycaemic range was comparatively similar between insulin icodec and the comparator [mean difference 2.42%, 95% CI (0.01-4.84), p = .05]. There was a significantly higher incidence of level 1 hypoglycaemia with insulin icodec but no significant difference was seen for the incidence of levels 2, 3 and combined 2/3 hypoglycaemia. Any adverse events and adverse events related to basal insulin were comparably similar in insulin icodec and comparators. The subgroup analysis of once-weekly insulin icodec with individual insulin analogues (glargine U100 and degludec) showed that insulin icodec had similar efficacy with insulin glargine U100 but superior efficacy with higher HbA1c reduction with insulin icodec compared with insulin degludec. The safety profile was comparable between insulin icodec and glargine U100, whereas insulin icodec reported higher incidence of hypoglycaemia events and any adverse events when compared with degludec. CONCLUSION: Once-weekly insulin icodec showed a better HbA1c reduction with a higher proportion of patients achieving HbA1c targets in comparison with once-daily basal insulin analogues. They were no major safety concerns with respect to hypoglycaemia or adverse events.


Asunto(s)
Diabetes Mellitus Tipo 2 , Hipoglucemia , Insulina de Acción Prolongada , Humanos , Insulina Glargina , Hipoglucemiantes/uso terapéutico , Hemoglobina Glucada , Ensayos Clínicos Controlados Aleatorios como Asunto , Insulina/efectos adversos , Hipoglucemia/inducido químicamente , Hipoglucemia/tratamiento farmacológico , Glucemia/análisis
13.
Diabetes Obes Metab ; 26(4): 1314-1320, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38177091

RESUMEN

AIM: Hypoglycaemic events are linked to microvascular and macrovascular complications in people with type 1 diabetes. We aimed to evaluate the efficacy of glucose sensor [real-time continuous glucose monitoring (RT-CGM)] with predictive alarm (PA) in reducing the time spent below the range (%TBR <70 mg/dl) in a group of adolescents with type 1 diabetes (AwD). MATERIALS AND METHODS: This was a crossover, monocentric and randomized study. RT-CGM was set with Alarm on Threshold (AoT) at 70 mg/dl) or PA for hypoglycaemia (20 m before threshold). Twenty AwD were enrolled and randomized to either a PA/AoT or AoT/PA treatment sequence, in a 1:1 ratio. The two groups (PA vs. AoT) were compared using two-way repeated measures ANOVA taking account of the carryover effect. RESULTS: AwD using PA for hypoglycaemia spent less time in severe hypoglycaemia (%TBR2 <54 mg/dl; 0.32 ± 0.31 vs. 0.91 ± 0.90; p < .02) and hypoglycaemia (%TBR <70 mg/dl; 1.68 ± 1.06 vs. 2.90 ± 2.05; p < .02), with better glycaemia risk index (51.3 ± 11.0 vs. 61.5 ± 12.6; p ≤ .01). CONCLUSION: The use of RT-CGM with PA for hypoglycaemia technology in AwD using multiple daily insulin injection treatment could significantly reduce the risk of having hypoglycaemic events resulting in an improved quality of glucose control. CLINICAL TRIAL REGISTRATION NUMBER: NCT05574023.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Humanos , Adolescente , Diabetes Mellitus Tipo 1/complicaciones , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Automonitorización de la Glucosa Sanguínea/métodos , Control Glucémico , Glucemia , Hipoglucemia/inducido químicamente , Hipoglucemia/prevención & control , Hipoglucemia/tratamiento farmacológico , Hipoglucemiantes/efectos adversos , Insulina/efectos adversos
14.
Diabetes Obes Metab ; 26(3): 937-949, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38151748

RESUMEN

AIM: To report on the effectiveness and safety of the MiniMed 780G automated insulin delivery system in real-world users during the month of Ramadan. MATERIALS AND METHODS: CareLink Personal data were extracted from MiniMed 780G system users from the Gulf region. Users were included if they had ≥10 days of sensor glucose data during the month of Ramadan 2022 as well as in the month before and after. For the main analysis, continuous glucose monitoring endpoints were aggregated per month and were reported by time of day (daytime: 05.31-18.00 h, and night-time). Additional analyses were performed to study the pace at which the algorithm adapts. RESULTS: Glycaemic control was well kept in the 449 included users (mean sensor glucose = 152.6 ± 18.7 mg/dl, glucose management indicator = 7.0 ± 0.4%, time in range = 70.7 ± 11.0%, time below 70 mg/dl = 2.3 ± 2.3%). Albeit some metrics differed from the month before (p < .0001 for all), absolute differences were very small and considered clinically irrelevant. During Ramadan, there was no increased risk of hypoglycaemia during daytime (time below 70 mg/dl = 2.3 ± 2.4%), time in range was highest during daytime (80.0 ± 10.7%, night: 60.4 ± 15.3%), while time above 180 mg/dl was highest during night-time (37.3 ± 16.3%, day: 17.7 ± 10.7%). The algorithm adapted immediately upon lifestyle change. CONCLUSION: The MiniMed 780G automated insulin delivery system is effective, safe and fast in adapting to the substantial changes that occur in the lifestyle of people with type 1 diabetes during Ramadan.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Humanos , Insulina/efectos adversos , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemia/inducido químicamente , Hipoglucemia/epidemiología , Hipoglucemia/prevención & control , Insulina Regular Humana/uso terapéutico , Sistemas de Infusión de Insulina/efectos adversos , Hipoglucemiantes/efectos adversos
15.
Diabetes Obes Metab ; 26(1): 46-53, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37718554

RESUMEN

AIM: Frequent hypoglycaemia results in disruption to usual hypoglycaemic autonomic responses leading to impaired awareness of hypoglycaemia, which is associated with an increased risk of severe hypoglycaemia requiring third-party assistance (SH). The UK Driving and Vehicle Licensing Agency (DVLA) does not permit car driving if they have either a complete loss of hypoglycaemia awareness or more than one SH event a year. METHODS: The FreeStyle Libre (FSL) Association of British Clinical Diabetologists (ABCD) Nationwide Audit consists of data collected by clinicians during routine clinical work, submitted into a secure web-based tool held within the National Health Service (NHS) N3 network. Analysis of paired baseline and follow-up data for people with type 1 diabetes who also held a driving licence was undertaken. RESULTS: The study consisted of 6304 people who had data recorded about driving status from 102 UK specialist diabetes centres, of which 4218 held a driving licence: 4178 a group 1, standard licence, 33 a group 2, large lorries and buses, seven a taxi licence; 1819 did not drive. Paired baseline and follow-up data were available for a sub-cohort of 1606/4218. At a mean follow-up of 6.9 months [95% CI (6.8, 7.1)], the Gold score had improved (2.3 ± 1.5 vs. 2.0 ± 1.3 p < .001), and the number of people who experienced an SH episode was also significantly lower (12.1% vs. 2.7%, p < .001). CONCLUSION: This study suggests that intermittently scanned continuous glucose monitoring may improve impaired awareness of hypoglycaemia and reduce the number of people with type 1 diabetes with a driving licence experiencing a severe hypoglycaemic episode.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Humanos , Diabetes Mellitus Tipo 1/complicaciones , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/efectos adversos , Glucemia , Automonitorización de la Glucosa Sanguínea/métodos , Monitoreo Continuo de Glucosa , Medicina Estatal , Insulina/efectos adversos , Hipoglucemia/inducido químicamente , Hipoglucemia/epidemiología , Hipoglucemia/prevención & control
16.
Diabetes Obes Metab ; 26(2): 622-630, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37921083

RESUMEN

AIM: The study aim was to evaluate the feasibility, safety and efficacy of automated insulin delivery (AID) assisted by home health care (HHC) services in people with type 2 diabetes unable to manage multiple daily insulin injections (MDI) at home on their own. PATIENTS AND METHODS: This was an open label, multicentre, randomized, parallel group trial. In total, 30 adults with type 2 diabetes using MDI and requiring nursing support were randomly allocated to AID or kept their usual therapy over a 12-week period. Both treatments were managed with the support of HHC services. The primary outcome was the percentage time in the target glucose range of 70-180 mg/dl (TIR). Secondary outcomes included other continuous glucose monitoring metrics, glycated haemoglobin (HbA1c) levels, daily insulin doses, body weight, and of quality of life scores, fear of hypoglycaemia and satisfaction questionnaires. RESULTS: Age (69.7 vs. 69.3 years) and HbA1c (9.25 vs. 9.0) did not differ in MDI and AID at baseline. Compared with MDI, AID resulted in a significant increase in TIR by 27.4% [95% CI (15.0-39.8); p < .001], a decrease in time above range by 27.7% and an unchanged time below range of <1%. A between-group difference in HbA1c was 1.3% favouring AID. Neither severe hypoglycaemia nor ketoacidosis occurred in either group. Patient and caregiver satisfaction with AID was high. CONCLUSIONS: AID combined with tailored HHC services significantly improved glycaemic control with no safety issues in people with type 2 diabetes previously under an MDI regimen with HHC. AID should be considered a safe option in these people when lacking acceptable glucose control.


Asunto(s)
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Servicios de Atención de Salud a Domicilio , Hipoglucemia , Adulto , Humanos , Insulina/efectos adversos , Hipoglucemiantes/uso terapéutico , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Hemoglobina Glucada , Automonitorización de la Glucosa Sanguínea , Calidad de Vida , Glucemia , Resultado del Tratamiento , Sistemas de Infusión de Insulina , Hipoglucemia/inducido químicamente , Hipoglucemia/prevención & control , Hipoglucemia/tratamiento farmacológico , Insulina Regular Humana/uso terapéutico
17.
Diabetes Obes Metab ; 26(8): 3213-3222, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38774963

RESUMEN

AIM: Experimental hypoglycaemia blunts the counterregulatory hormone and symptom responses to a subsequent episode of hypoglycaemia. In this study, we aimed to assess the associations between antecedent exposure and continuous glucose monitoring (CGM)-recorded hypoglycaemia during a 1-week period and the counterregulatory responses to subsequent experimental hypoglycaemia in people with type 1 diabetes. MATERIALS AND METHODS: Forty-two people with type 1 diabetes (20 females, mean ± SD glycated haemoglobin 7.8% ± 1.0%, diabetes duration median (interquartile range) 22.0 (10.5-34.9) years, 29 CGM users, and 19 with impaired awareness of hypoglycaemia) wore an open intermittently scanned CGM for 1 week to detect hypoglycaemic exposure before a standardized hyperinsulinaemic-hypoglycaemic [2.8 ± 0.1 mmol/L (50.2 ± 2.3 mg/dl)] glucose clamp. Symptom responses and counterregulatory hormones were measured during the clamp. The study is part of the HypoRESOLVE project. RESULTS: CGM-recorded hypoglycaemia in the week before the clamp was negatively associated with adrenaline response [ß -0.09, 95% CI (-0.16, -0.02) nmol/L, p = .014], after adjusting for CGM use, awareness of hypoglycaemia, glycated haemoglobin and total daily insulin dose. This was driven by level 2 hypoglycaemia [<3.0 mmol/L (54 mg/dl)] [ß -0.21, 95% CI (-0.41, -0.01) nmol/L, p = .034]. CGM-recorded hypoglycaemia was negatively associated with total, autonomic, and neuroglycopenic symptom responses, but these associations were lost after adjusting for potential confounders. CONCLUSIONS: Recent exposure to CGM-detected hypoglycaemia was independently associated with an attenuated adrenaline response to experimental hypoglycaemia in people with type 1 diabetes.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Diabetes Mellitus Tipo 1 , Técnica de Clampeo de la Glucosa , Hipoglucemia , Hipoglucemiantes , Humanos , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/complicaciones , Diabetes Mellitus Tipo 1/fisiopatología , Femenino , Hipoglucemia/inducido químicamente , Hipoglucemia/sangre , Hipoglucemia/etiología , Masculino , Adulto , Glucemia/análisis , Glucemia/metabolismo , Hipoglucemiantes/efectos adversos , Hipoglucemiantes/uso terapéutico , Epinefrina/sangre , Insulina/administración & dosificación , Insulina/efectos adversos , Persona de Mediana Edad , Hemoglobina Glucada/análisis , Hemoglobina Glucada/metabolismo , Control Glucémico , Monitoreo Continuo de Glucosa
18.
Diabetes Obes Metab ; 26(8): 3361-3370, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38826105

RESUMEN

AIM: To assess the differential association of risk factors with severe and non-severe hypoglycaemia. MATERIALS AND METHODS: The Hypoglycaemia Assessment Tool study evaluated the risk of hypoglycaemia over a 4-week period in patients with type 1 diabetes (T1D) and type 2 diabetes (T2D) on insulin in 24 countries. Negative binomial regressions were applied to examine the associations of several risk factors with severe and non-severe hypoglycaemia. RESULTS: The median age was 41 years in 5949 patients with T1D and 62 years in 12 914 patients with T2D. The 4-week rates of non-severe hypoglycaemic were 5.57 and 1.40 episodes per person in T1D and T2D, respectively; the corresponding rates for severe hypoglycaemia were 0.94 and 0.30. The excess risk was 42% higher for severe than non-severe hypoglycaemia in females versus males with T2D; 27% higher in patients with T2D with versus without a continuous glucose monitoring (CGM); and 47% lower in patients with T1D with versus without an insulin pump. The excess risk also differed across geographical areas and was marginally lower for severe than non-severe hypoglycaemia for higher values of HbA1c in patients with T2D. Associations with severity of hypoglycaemia were not different for age, diabetes and insulin therapy duration, previous hypoglycaemic episodes and insulin regimen. CONCLUSIONS: The risk of severe versus non-severe hypoglycaemia differs in patients with T1D and T2D; sex, the use of a CGM and insulin pump, and geographical areas were differently associated with one type of hypoglycaemia than the other.


Asunto(s)
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Hipoglucemia , Hipoglucemiantes , Insulina , Humanos , Hipoglucemia/inducido químicamente , Hipoglucemia/epidemiología , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/complicaciones , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/sangre , Masculino , Femenino , Persona de Mediana Edad , Adulto , Factores de Riesgo , Insulina/efectos adversos , Insulina/uso terapéutico , Hipoglucemiantes/efectos adversos , Hipoglucemiantes/uso terapéutico , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Anciano , Hemoglobina Glucada/análisis , Glucemia/análisis , Glucemia/metabolismo , Automonitorización de la Glucosa Sanguínea
19.
Diabetes Obes Metab ; 26(7): 2652-2661, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38602411

RESUMEN

AIM: To provide updated efficacy and safety information for teplizumab in the treatment of Stage 3 type 1 diabetes mellitus (T1DM). MATERIALS AND METHODS: The PubMed, Embase and Cochrane databases were searched for randomized controlled trials (RCTs) comparing teplizumab to placebo for T1DM that reported any of the following outcomes: (1) C-peptide area under the curve (AUC); (2) glycated haemoglobin (HbA1c) levels; (3) insulin requirements; and (4) adverse events. Heterogeneity was examined with I2 statistics. p values <0.05 were taken to indicate statistical significance. The continuous endpoints were compared through the pooled mean difference (MD) and binary endpoints were assessed using risk ratios, both with 95% confidence intervals (CIs). Statistical analyses were performed using Review Manager Web software. RESULTS: Eight RCTs with 1052 patients (754 receiving teplizumab) were included. Teplizumab significantly increased the AUC of C-peptide levels at 6 (MD 0.10 nmol/L, 95% CI 0.05, 0.16), 12 (MD 0.13 nmol/L, 95% CI 0.06, 0.20), 18 (MD 0.18 nmol/L, 95% CI 0.09, 0.27) and 24 months (MD 0.16 nmol/L, 95% CI 0.02, 0.31), significantly reduced HbA1c levels at 6 (MD -0.57%, 95% CI -1.07, -0.08) and 12 months (MD -0.31%, 95% CI -0.59, -0.02), and significantly reduced insulin requirements at 6 (MD -0.12 U/kg, 95% CI -0.16, -0.08), 12 (MD -0.11 U/kg, 95% CI -0.15, -0.07), 18 (MD -0.17 U/kg, 95% CI -0.26, -0.09) and 24 months (MD -0.11 U/kg, 95% CI -0.22, -0.01). CONCLUSION: Teplizumab increases AUC of C-peptide levels and decreases HbA1c levels and insulin use, without raising serious adverse event risk.


Asunto(s)
Anticuerpos Monoclonales Humanizados , Diabetes Mellitus Tipo 1 , Hemoglobina Glucada , Hipoglucemiantes , Adulto , Femenino , Humanos , Masculino , Anticuerpos Monoclonales Humanizados/uso terapéutico , Anticuerpos Monoclonales Humanizados/efectos adversos , Péptido C/sangre , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Hemoglobina Glucada/análisis , Hemoglobina Glucada/efectos de los fármacos , Hemoglobina Glucada/metabolismo , Hipoglucemia/inducido químicamente , Hipoglucemiantes/uso terapéutico , Hipoglucemiantes/efectos adversos , Insulina/uso terapéutico , Insulina/efectos adversos , Ensayos Clínicos Controlados Aleatorios como Asunto , Resultado del Tratamiento
20.
Diabetes Obes Metab ; 26(9): 3801-3809, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38923379

RESUMEN

AIM: To compare the efficacy and safety profiles of recent innovations in type 2 diabetes mellitus (T2DM), which include once-weekly formulations such as tirzepatide, a dual glucagon-like peptide-1 and glucose-dependent insulinotropic polypeptide receptor agonist, and once-weekly insulin options such as icodec and basal insulin Fc. METHODS: A systematic search of the PubMed, Scopus, Cochrane, and Web of Science databases was conducted. The network meta-analysis protocol was registered at OSF registries (https://osf.io/gd67x). The primary outcome of interest was change in glycated haemoglobin (HbA1c), with change in fasting plasma glucose (FPG), body weight, incidence of hypoglycaemia, and treatment discontinuation as secondary outcomes. RESULTS: Tirzepatide exhibited superior efficacy in reducing HbA1c levels compared with insulin therapies, with the 15-mg dose showing the most significant reduction (mean difference [MD] -1.27, 95% confidence interval [CI] -1.49; -1.0). In terms of FPG reduction, tirzepatide 15 mg ranked highest (MD -0.70, 95% CI -1.05; -0.34), followed by tirzepatide 10 mg and 5 mg. Additionally, tirzepatide led to substantial weight loss, with the 15-mg dose exhibiting the most pronounced effect (MD -12.13, 95% CI -13.98; -10.27). However, a higher incidence of adverse events (AEs) and treatment discontinuation were associated with tirzepatide, particularly at higher doses. CONCLUSION: Tirzepatide, particularly at higher doses, demonstrates superior efficacy in lowering HbA1c and reducing hypoglycaemia risk compared with weekly insulin. However, its use is also associated with a higher incidence of AEs and treatment discontinuation.


Asunto(s)
Glucemia , Diabetes Mellitus Tipo 2 , Hemoglobina Glucada , Hipoglucemiantes , Insulina , Metaanálisis en Red , Ensayos Clínicos Controlados Aleatorios como Asunto , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 2/sangre , Humanos , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/uso terapéutico , Hipoglucemiantes/efectos adversos , Insulina/administración & dosificación , Insulina/uso terapéutico , Insulina/efectos adversos , Hemoglobina Glucada/análisis , Hemoglobina Glucada/efectos de los fármacos , Resultado del Tratamiento , Glucemia/efectos de los fármacos , Esquema de Medicación , Hipoglucemia/inducido químicamente , Hipoglucemia/epidemiología , Masculino , Femenino , Persona de Mediana Edad , Receptor del Péptido 2 Similar al Glucagón , Polipéptido Inhibidor Gástrico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA