Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
JACC Heart Fail ; 12(8): 1396-1405, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38739124

RESUMO

BACKGROUND: Limited evidence exists regarding efficacy and safety of diuretic regimens in ambulatory, congestion-refractory, chronic heart failure (CHF) patients. OBJECTIVES: The authors sought to compare the potency and safety of commonly used diuretic regimens in CHF patients. METHODS: A prospective, randomized, open-label, crossover study conducted in NYHA functional class II to IV CHF patients, treated in an ambulatory day-care unit. Each patient received 3 different diuretic regimens: intravenous (IV) furosemide 250 mg; IV furosemide 250 mg plus oral metolazone 5 mg; and IV furosemide 250 mg plus IV acetazolamide 500 mg. Treatments were administered once a week, in 1 of 6 randomized sequences. The primary endpoint was total sodium excretion, and the secondary was total urinary volume excreted, both measured for 6 hours post-treatment initiation. RESULTS: A total of 42 patients were recruited. Administration of furosemide plus metolazone resulted in the highest weight of sodium excreted, 4,691 mg (95% CI: 4,153-5,229 mg) compared with furosemide alone, 3,835 mg (95% CI: 3,279-4,392 mg; P = 0.015) and to furosemide plus acetazolamide 3,584 mg (95% CI: 3,020-4,148 mg; P = 0.001). Furosemide plus metolazone resulted in 1.84 L of urine (95% CI: 1.63-2.05 L), compared with 1.58 L (95% CI: 1.37-1.8); P = 0.039 collected following administration of furosemide plus acetazolamide and 1.71 L (95% CI: 1.49-1.93 L) following furosemide alone. The incidence of worsening renal function was significantly higher when adding metolazone (39%) to furosemide compared with furosemide alone (16%) and to furosemide plus acetazolamide (2.6%) (P < 0.001). CONCLUSIONS: In ambulatory CHF patients, furosemide plus metolazone resulted in a significantly higher natriuresis compared with IV furosemide alone or furosemide plus acetazolamide.


Assuntos
Acetazolamida , Estudos Cross-Over , Diuréticos , Furosemida , Insuficiência Cardíaca , Metolazona , Humanos , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/fisiopatologia , Furosemida/administração & dosagem , Furosemida/uso terapêutico , Masculino , Feminino , Diuréticos/administração & dosagem , Diuréticos/uso terapêutico , Acetazolamida/administração & dosagem , Acetazolamida/uso terapêutico , Metolazona/administração & dosagem , Idoso , Estudos Prospectivos , Pessoa de Meia-Idade , Quimioterapia Combinada , Diurese/efeitos dos fármacos , Resultado do Tratamento
2.
Rambam Maimonides Med J ; 11(3)2020 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-32792042

RESUMO

The coronavirus disease 2019 (COVID-19) pandemic has remarkably challenged health care organizations and societies. A key strategy for confronting the disease implications on individuals and communities was based on harnessing multidisciplinary efforts to develop technologies for mitigating the disease spread and its deleterious clinical implications. One of the main challenging characteristics of COVID-19 is the provision of medical care to patients with a highly infective disease mandating the use of isolation measures. Such care is complicated by the need for complex critical care, dynamic treatment guidelines, and a vague knowledge regarding the disease's pathophysiology. A second key component of this challenge was the overwhelming surge in patient burden and the relative lack of trained staff and medical equipment which required rapid re-organization of large systems and augmenting health care efficiencies to unprecedented levels. In contrast to the risk management strategies employed to mitigate other serious threats and the billions of dollars that are invested in reducing these risks annually by governments around the world, no such preparation has been shown to be of effect during the current COVID-19 pandemic. Unmet needs were identified within the newly opened COVID-19 departments together with the urgent need for reliable information for effective decision-making at the state level.This review article describes the early research and development response in Israel under the scope of in-hospital patient care, such as non-contact sensing of patients' vital signs, and how it could potentially be weaved into a practical big picture at the hospital or national level using a strategic management system. At this stage, some of the described technologies are still in developmental or clinical evidence generation phases with respect to COVID-19 settings. While waiting for future publications describing the results of the ongoing evidence generation efforts, one should be aware of this trend as these emerging tools have the potential to further benefit patients as well as caregivers and health care systems beyond the scope of the current pandemic as well as confronting future surges in the number of cases.

3.
JACC Case Rep ; 2(14): 2176-2182, 2020 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-34317133

RESUMO

Transcatheter therapies to treat tricuspid regurgitation are being developed, but few have attempted the gold standard of surgical repair: ring annuloplasty. We describe the first-ever fully percutaneous implantation of a circumferential, semirigid annuloplasty ring to treat massive secondary tricuspid regurgitation. (Level of Difficulty: Advanced.).

4.
J Cardiovasc Electrophysiol ; 20(6): 567-604, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19207761

RESUMO

Integration of 3D PET with Voltage Map for VT Ablation. Background: Image integration has the potential to display three-dimensional (3D) scar anatomy and facilitate substrate characterization for ventricular tachycardia (VT) ablation. However, the current generation of clinical mapping systems cannot display 3D left ventricle (LV) anatomy with embedded 3D scar reconstructions or allow display of border zone and high-resolution anatomic scar features. Objective: This study reports the first clinical experience with a mapping system allowing an integrated display of 3D LV anatomy with detailed 2D/3D scar and border zone reconstruction. Methods: Ten patients scheduled for VT ablation underwent contrast-enhanced computed tomography (CT) and Rubidium-82 perfusion/F-18 Fluorodeoxyglucose metabolic Positron Emission Tomography (PET) imaging to reconstruct 3D LV and scar anatomy. LV and scar models were co-registered using a 3D mapping system and analyzed with a 17-segment model. Metabolic thresholding was used to reconstruct the 3D border zone. Real-time display of CT images was performed during ablation. Results: Co-registration (error 4.3 +/- 0.7 mm) allowed simultaneous visualization of 3D LV anatomy and embedded scar and guided additional voltage mapping. Segments containing homogenous or partial scar correlated in 94.4% and 85.7% between voltage maps and 3D PET scar reconstructions, respectively. Voltage-defined scar and normal myocardium had relative FDG uptakes of 40 +/- 13% and 89 +/- 30% (P < 0.05). The 3D border zone correlated best with a 46% metabolic threshold. Real-time display of registered high-resolution CT images allowed the simultaneous characterization of scar-related anatomic changes. Conclusion: Integration of PET/CT reconstruction allows simultaneous 3D display of myocardial scar and border zone embedded into the LV anatomy as well as the display of detailed scar anatomy. Multimodality imaging may enable a new image-guided approach to substrate-guided VT ablation.


Assuntos
Técnicas de Ablação/métodos , Traumatismos Cardíacos/patologia , Miocárdio/patologia , Tomografia por Emissão de Pósitrons/métodos , Taquicardia Ventricular/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Cardiomiopatias , Cicatriz/terapia , Desfibriladores Implantáveis/efeitos adversos , Feminino , Ventrículos do Coração/patologia , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/métodos
5.
J Am Heart Assoc ; 7(22): e009175, 2018 11 20.
Artigo em Inglês | MEDLINE | ID: mdl-30571493

RESUMO

Background Right heart catheterization is the gold standard in clinical practice for the assessment of cardiovascular hemodynamics, but it is an invasive procedure requiring expertise in both insertion and reading. Remote dielectric sensing (Re DS ) is a noninvasive electromagnetic-based technology intended to quantify lung fluid content. Methods and Results In this prospective single-center study, Re DS readings were obtained in supine position just before right heart catheterization procedure in patients with heart failure. Agreement between Re DS and pulmonary artery wedge pressure ( PAWP ) was analyzed. Of all, 139 patients with heart failure received hemodynamic assessment and Re DS measurement. A good correlation was found between Re DS and PAWP measurement ( r=0.492, P<0.001). Receiver operating characteristic analysis of the ability to identify a PAWP ≥18 mm Hg resulted in a Re DS cutoff value of 34%, with an area under the curve of 0.848, a sensitivity of 90.7%, and a specificity of 77.1%. Overall, Re DS <34% carries a high negative predictive value of 94.9%. Conclusions Lung fluid content, as measured by Re DS , correlates well with PAWP . The high sensitivity and specificity and especially the high negative predictive value make Re DS a reliable noninvasive tool at the point of care, to rule out elevated PAWP in patients with heart failure and to help with medical management of patients with heart failure. Further studies are warranted to compare this tool with existing tests and to relate the findings to the clinical outcomes.


Assuntos
Coração/fisiologia , Hemodinâmica , Pulmão/patologia , Pressão Propulsora Pulmonar , Tecnologia de Sensoriamento Remoto , Cateterismo Cardíaco , Circulação Coronária , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tecnologia de Sensoriamento Remoto/instrumentação , Tecnologia de Sensoriamento Remoto/métodos , Sensibilidade e Especificidade
6.
Int J Cardiol ; 240: 279-284, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28341372

RESUMO

OBJECTIVE: We tested whether remote dielectric sensing (ReDS)-directed fluid management reduces readmissions in patients recently hospitalized for heart failure (HF). BACKGROUND: Pulmonary congestion is the most common cause of worsening HF leading to hospitalization. Accurate remote monitoring of lung fluid volume may guide optimal treatment and prevent re-hospitalization. ReDS technology is a quantitative non-invasive method for measuring absolute lung fluid volume. METHODS: Patients hospitalized for acute decompensated HF were enrolled during their index admission and followed at home for 90days post-discharge. Daily ReDS readings were obtained using a wearable vest, and were used as a guide to optimizing HF therapy, with a goal of maintaining normal lung fluid content. Comparisons of the number of HF hospitalizations during ReDS-guided HF therapy were made, both to the 90days prior to enrollment and to the 90days following discontinuation of ReDS monitoring. RESULTS: Fifty patients were enrolled, discharged, and followed at home for 76.9±26.2days. Patients were 73.8±10.3years old, 40% had LVEF above 40%, and 38% were women. Compared to the pre- and post-ReDS periods, there were 87% and 79% reductions in the rate of HF hospitalizations, respectively, during ReDS-guided HF therapy. The hazard ratio between the ReDS and the pre-ReDS period was 0.07 (95% CI [0.01-0.54] p=0.01), and between the ReDS and the post-ReDS period was 0.11 (95% CI [0.014-0.88] p=0.037). CONCLUSIONS: These findings suggest that ReDS-guided management has the potential to reduce HF readmissions in acute decompensated HF patients recently discharged from the hospital.


Assuntos
Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Readmissão do Paciente , Tecnologia de Sensoriamento Remoto/normas , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Insuficiência Cardíaca/sangue , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Readmissão do Paciente/tendências , Estudos Prospectivos , Tecnologia de Sensoriamento Remoto/tendências
7.
Int J Cardiol ; 221: 841-6, 2016 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-27434357

RESUMO

BACKGROUND: Pulmonary congestion is a common presentation of acute decompensated heart failure (ADHF). The ability to quantify increased pulmonary parenchymal water content in chest computed tomography (CCT) is well known. However, availability and radiation limitations make it unsuitable for serial assessment of lung fluid content. The ReDS™ technology allows quantification of lung fluid content. OBJECTIVE: The objective of this work was to validate the ability of the ReDS™ technology to quantify total lung fluid when compared with CCT in ADHF and non-ADHF patients. METHODS: Following CCT, ReDS measurements were obtained from consented subjects. ReDS measurements were then compared to the CCT using lung density analysis software. CCT results were converted from Hounsfield Units to percentage units, allowing comparison with the ReDS readings. The analyses, performed on 16 ADHF and 15 non-ADHF patients, were conducted by an independent observer blinded to ReDS outcomes. RESULTS: The fluid content averages and standard deviations for the non-ADHF group were 28.7±5.9% and 27.3±6.6% and for the ADHF patients 40.7±8.8% and 39.8±6.8% (CCT and ReDS respectively). Intraclass correlation was found to be 0.90, 95% CI [0.8-0.95]. Regression analysis yielded a slope of 0.94 (95% confidence interval [0.77-1.12]) and intercept 3.10 (95% confidence interval of [-3.02-9.21]). The absolute mean difference between the quantification of the two methods was 3.75 [%] with SD of 2.22 [%]. CONCLUSION: Current findings show high correlation between the ReDS noninvasive system and CCT in both ADHF and non-ADHF patients. Remote patient monitoring using ReDS™ based system may help in the management of patients with heart failure.


Assuntos
Insuficiência Cardíaca/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Tecnologia de Sensoriamento Remoto/normas , Tomografia Computadorizada por Raios X/normas , Doença Aguda , Idoso , Idoso de 80 Anos ou mais , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Pulmão/fisiopatologia , Masculino , Pessoa de Meia-Idade
9.
Circ Arrhythm Electrophysiol ; 3(5): 496-504, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20657032

RESUMO

BACKGROUND: Advances in contrast-enhanced multidetector CT enable detailed characterization of the left ventricular myocardium. Myocardial scar and border zone (BZ), as the target of ventricular tachycardia ablations, displays abnormal anatomic, dynamic, and perfusion characteristics during first-pass CT. This study assessed how contrast-enhanced CT can predict voltage-defined scar and BZ and integrate its scar reconstructions into clinical mapping systems to guide ventricular tachycardia ablations. METHODS AND RESULTS: Eleven patients with ischemic cardiomyopathy underwent contrast-enhanced CT before ventricular tachycardia ablation. Segmental anatomic (end-systolic and end-diastolic wall thickness), dynamic (wall thickening, wall motion), and perfusion (hypoenhancement) characteristics were evaluated. Receiver operating characteristic curves assessed the ability of CT to determine voltage-defined scar and BZ segments. Three-dimensional epi- and endocardial surfaces and scar borders were reconstructed, coregistered, and compared to voltages using a 17-segment model. Abnormal anatomic, dynamic, and perfusion data correlated well with abnormal (<1.5 mV) endocardial voltages (r=0.77). Three-dimensional reconstruction integrated into the clinical mapping system (registration accuracy, 3.31±0.52 mm) allowed prediction of homogenous abnormal voltage (<1.5 mV) in 81.7% of analyzed segments and correctly displayed transmural extent and intramural scar location. CT hypoperfusion correlated best with scar and BZ areas and encompassed curative ablations in 82% cases. CONCLUSIONS: Anatomic, dynamic, and perfusion imaging using contrast-enhanced CT allows characterization of left ventricular anatomy and 3D scar and BZ substrate. Integration of reconstructed 3D data sets into clinical mapping systems supplements information of voltage mapping and may enable new image approaches for substrate-guided ventricular tachycardia ablation.


Assuntos
Ablação por Cateter/métodos , Meios de Contraste/farmacologia , Imageamento Tridimensional/métodos , Isquemia Miocárdica/diagnóstico por imagem , Imagem de Perfusão/métodos , Taquicardia Ventricular/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Mapeamento Potencial de Superfície Corporal , Diagnóstico Diferencial , Feminino , Seguimentos , Humanos , Masculino , Isquemia Miocárdica/complicações , Isquemia Miocárdica/fisiopatologia , Reprodutibilidade dos Testes , Taquicardia Ventricular/complicações , Taquicardia Ventricular/cirurgia
10.
Emerg Infect Dis ; 11(1): 22-9, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15705318

RESUMO

To understand the epidemiology of multidrug-resistant (MDR) Acinetobacter baumannii and define individual risk factors for multidrug resistance, we used epidemiologic methods, performed organism typing by pulsed-field gel electrophoresis (PFGE), and conducted a matched case-control retrospective study. We investigated 118 patients, on 27 wards in Israel, in whom MDR A. baumannii was isolated from clinical cultures. Each case-patient had a control without MDR A. baumannii and was matched for hospital length of stay, ward, and calendar time. The epidemiologic investigation found small clusters of up to 6 patients each with no common identified source. Ten different PFGE clones were found, of which 2 dominated. The PFGE pattern differed within temporospatial clusters, and antimicrobial drug susceptibility patterns varied within and between clones. Multivariate analysis identified the following significant risk factors: male sex, cardiovascular disease, having undergone mechanical ventilation, and having been treated with antimicrobial drugs (particularly metronidazole). Penicillins were protective. The complex epidemiology may explain why the emergence of MDR A. baumannii is difficult to control.


Assuntos
Infecções por Acinetobacter/epidemiologia , Acinetobacter baumannii/efeitos dos fármacos , Doenças Transmissíveis Emergentes/epidemiologia , Infecção Hospitalar/epidemiologia , Farmacorresistência Bacteriana Múltipla , Hospitais de Ensino , Infecções por Acinetobacter/microbiologia , Acinetobacter baumannii/classificação , Acinetobacter baumannii/genética , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Doenças Transmissíveis Emergentes/microbiologia , Infecção Hospitalar/microbiologia , Eletroforese em Gel de Campo Pulsado , Feminino , Humanos , Israel/epidemiologia , Masculino , Testes de Sensibilidade Microbiana , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA