Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 102(2): 247-248, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37369982

RESUMO

During left main (LM) bifurcation PCI using T and small protrusion (TAP) technique, after deployment of LM-left anterior descending (LAD) stent, left circumflex (LCx) stent was entangled at LM ostium with balloon and wire slippage. Ping-pong (dual) guide catheters were used to simultaneously fix the LM-LAD stent and snare the trapped stent. This technique proved effective in retrieving the lost stent and minimizing LM stent deformation.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Angiografia Coronária/métodos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Resultado do Tratamento , Stents , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia
2.
Heart Vessels ; 38(4): 599-605, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36301342

RESUMO

Evaluation of mechanical prosthetic valve function is based on echocardiography, but adequate assessment of leaflet motion is limited by acoustic shadowing. Cinefluoroscopy is a standard method to assess leaflet motion, while computed tomography (CT) has been suggested as an alternative. We sought to compare the feasibility of leaflet motion assessment by cinefluoroscopy vs. CT. In 35 prospectively enrolled patients, leaflet motion was assessed in 43 bileaflet mechanical prostheses (29 mitral and 14 aortic) by cinefluoroscopy and non-contrast CT. Assessment was considered feasible when the 'in profile' projection (with the radiographic beam parallel to both the valve ring plane and the tilting axis of discs) could be achieved. Overall feasibility of fluoroscopic assessment was 74% (mitral, 66% vs. aortic, 93%; p = 0.071), while feasibility of CT assessment was 100% (p = 0.003). Among prostheses with unfeasible fluoroscopic assessment, CT suggested an extreme C-arm angulation to achieve the "in profile" projection (RAO: 76.0 ± 5.8°, LAO: 122.7 ± 32.5°, CRA: 51.4 ± 16.0°, CAU: 57.0 ± 18.2°). Among prostheses with feasible assessment by both techniques, fluoroscopy and CT yielded similar opening and closing angles (intraclass correlation coefficient, 0.959-0.998) with lower irradiation with CT as compared with fluoroscopy (26.2[21.1-29.3] vs. 289[179-358] mGy, p < 0.001). While CT scan took 8.7 ± 0.5 s, fluoroscopy required 2.64 ± 1.56 min to achieve and record the "in profile" projection. Non-contrast CT provides a higher feasibility and a quicker evaluation of mechanical prosthetic valve leaflet motion with less irradiation than fluoroscopy, especially in mitral valve position.


Assuntos
Próteses Valvulares Cardíacas , Humanos , Valva Aórtica/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Valva Mitral/diagnóstico por imagem , Ecocardiografia
3.
Cardiology ; 147(4): 461-468, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35947973

RESUMO

BACKGROUND: Prosthetic valve regurgitation (PVR) impairs early and mid-term outcomes after transcatheter aortic valve replacement (TAVR). We explored the impact of PVR assessed by transthoracic echocardiography (TTE) and magnetic resonance imaging-regurgitation fraction (MRI-RF) on long-term clinical outcomes. METHODS: PVR was assessed by TTE applying the Valve Academic Research Consortium criteria and MRI-RF (from velocity-encoded phase contrast magnetic resonance sequence) in 424 patients. RESULTS: MRI-RF correlated modestly with the echocardiographic grades of PVR (Spearman's rank correlation coefficient = 0.32, p < 0.001). Using an MRI-RF ≥20% to define ≥ moderate PVR, echocardiography and MRI-RF agreed on PVR classification in 412 patients (97.2%; kappa statistic = 0.56, p < 0.001). Five-year mortality or reintervention was higher in patients with echocardiographic ≥ moderate PVR (83.3% vs. 45.0%, log rank p value = 0.002; HR [95% CI]: 3.18 [1.48-6.84]) as well as in patients with MRI-RF ≥20% (79.3% vs. 43.2%, log rank p value <0.001; HR [95% CI]: 2.68 [1.53-4.70]), while the outcomes of patients with echocardiographic mild PVR were not significantly different from those with none-trace PVR. In the two latter groups (echocardiographic < moderate PVR), MRI-RF ≥20% was associated with a significantly higher 5-year mortality or reintervention as compared with MRI-RF <20% (79.5% vs. 42.2%, log rank p value = 0.023; HR [95% CI]: 2.26 [1.10-4.65]). CONCLUSIONS: Greater than mild PVR as defined by TTE or MRI-RF is associated with impaired long-term clinical outcomes after TAVR. MRI-RF can be used to further risk-stratify patients with echocardiographic less-than-moderate PVR.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Humanos , Imageamento por Ressonância Magnética , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
4.
Eur Heart J ; 41(20): 1932-1940, 2020 05 21.
Artigo em Inglês | MEDLINE | ID: mdl-31511897

RESUMO

Tricuspid regurgitation (TR) is a frequent and complex problem, commonly combined with left-sided heart disease, such as mitral regurgitation. Significant TR is associated with increased mortality if left untreated or recurrent after therapy. Tricuspid regurgitation was historically often disregarded and remained undertreated. Surgery is currently the only Class I Guideline recommended therapy for TR, in the form of annuloplasty, leaflet repair, or valve replacement. As growing experience of transcatheter therapy in structural heart disease, many dedicated transcatheter tricuspid repair or replacement devices, which mimic well-established surgical techniques, are currently under development. Nevertheless, many aspects of TR are little understood, including the disease process, surgical or interventional risk stratification, and predictors of successful therapy. The optimal treatment timing and the choice of proper surgical or interventional technique for significant TR remain to be elucidated. In this context, we aim to highlight the current evidence, underline major controversial issues in this field and present a future roadmap for TR therapy.


Assuntos
Anuloplastia da Valva Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Valva Mitral/cirurgia , Resultado do Tratamento , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/cirurgia
5.
Catheter Cardiovasc Interv ; 93(3): 382-389, 2019 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-30196568

RESUMO

OBJECTIVES: We aimed to investigate the feasibility, safety, and outcome of rotational atherectomy (RA) in the setting of acute coronary syndrome (ACS). BACKGROUND: Limited data are available on the use of RA in patients presenting with ACS. METHODS: This analysis is from an observational registry, which enrolled all consecutive patients undergoing RA in a tertiary center. Between 2002 and 2015, 433 patients with stable coronary artery disease (SCAD) were treated with RA. Within the same period, 108 patients with ACS (8 STEMI and 100 NSTE-ACS) were treated with RA. Procedural success was similar between the ACS and the SCAD groups (96.6% vs. 96.4%, P = 0.90), and no significant difference was observed in procedural complications (slow-flow: 0.8% vs. 2.8%, P = 0.32; coronary dissection: 6.8% vs. 7.2%, P = 1.00; coronary perforation: 0.8% vs. 1.7%, P = 0.69). In-hospital MACE rates were comparable (3.7% vs. 3.2%, P = 0.77). The risk of MACE within 24 months was higher in ACS patients (39.9% vs. 22.4%, log-rank P = 0.002; HR: 1.39; 95% CI: 1.12-1.73; P = 0.003). Multivariable Cox regression analysis identified left ventricular ejection fraction (HR 0.97; 95% CI: 0.85-0.99; P = 0.001), treatment with a BMS (HR 2.22, 95% CI: 1.15-4.25, P = 0.02) or early generation drug eluting stent (HR 1.99; 95% CI 1.09-3.64; P = 0.03), as well as ACS presentation (HR 1.53; 95% CI: 1.02-2.29; P = 0.04) as predictors of MACE at two years. CONCLUSIONS: RA is technically feasible and safe in high risk patients presenting with ACS. However, successful application of RA did not mitigate the higher rate of long term cardiovascular events.


Assuntos
Síndrome Coronariana Aguda/terapia , Aterectomia Coronária , Infarto do Miocárdio sem Supradesnível do Segmento ST/terapia , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/mortalidade , Idoso , Idoso de 80 Anos ou mais , Aterectomia Coronária/efeitos adversos , Aterectomia Coronária/mortalidade , Stents Farmacológicos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio sem Supradesnível do Segmento ST/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/mortalidade , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Fatores de Tempo , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 93(5): 971-979, 2019 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-30467966

RESUMO

OBJECTIVES: To investigate the impact of the introduction of the next generation self-expanding (SE) and balloon-expandable (BE) transcatheter heart valves (THVs) on the incidence of prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR). BACKGROUND: PPM is a risk factor for accelerated degeneration of bioprosthetic aortic valves. Data on PPM after TAVR are derived mainly from studies of older generation THVs. METHODS: PPM was assessed at 30 days post-TAVR with the older generation (Medtronic CoreValve, n = 120 and Edwards Sapien XT, n = 121) and the next generation THVs (Medtronic Evolut R/Pro, n = 136 and Edwards Sapien 3, n = 363). RESULTS: The incidence of any and severe PPM was 15.1% and 0.0% for the older generation THVs, and 42.8% and 12.1% for the next generation THVs. The incidence of moderate and severe PPM was 23.3% and 3.5% in patients who received an Evolut R/Pro vs. 33.1% and 14.7% in those who received a Sapien 3 (P < 0.001). On multivariable analysis, TAVR with the Sapien 3 THV was not associated with PPM, while left ventricular ejection fraction (0.97 [0.95-0.99], P = 0.002), history of myocardial infarction (2.09 [1.00-4.34], P = 0.049), annulus maximum diameter (0.84 [0.77-0.92], P < 0.001), and THV oversizing (0.90 [0.87-0.94], P < 0.001) were independently associated with PPM. In Sapien 3, the risk of any and severe PPM was higher in those with no oversizing (odds ratio: 3.25 [1.23-8.53], P = 0.017 and 5.79[2.33-14.36], P < 0.001). CONCLUSIONS: The incidence of PPM in contemporary TAVR is significant, especially with the next generation BE THV without adequate oversizing.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão , Feminino , Humanos , Incidência , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Sistema de Registros , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
7.
Cardiology ; 143(1): 62-72, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31307049

RESUMO

Patent foramen ovale (PFO) is a common benign finding in healthy subjects, but its prevalence is higher in patients with stroke of unclear cause (cryptogenic stroke). PFO is believed to be associated with stroke through paradoxical embolism, and certain clinical and anatomical criteria seem to increase the likelihood of a PFO to be pathological. Recent trials have shown that closure of PFO, especially if associated with an atrial septal aneurysm and/or a large interatrial shunt, may reduce the risk of recurrent stroke as compared to medical treatment. However, it remains challenging to risk stratify patients with suspected PFO-related stroke and to decide if device closure is indicated. We sought to review contemporary evidence and to conclude an evidence-based strategy to prevent recurrence of PFO-related stroke.


Assuntos
Forame Oval Patente/complicações , Forame Oval Patente/terapia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/terapia , Anticoagulantes/uso terapêutico , Tomada de Decisão Clínica , Ensaios Clínicos como Assunto , Eletrocardiografia , Embolia Paradoxal/complicações , Embolia Paradoxal/etiologia , Humanos , Medição de Risco , Prevenção Secundária , Dispositivo para Oclusão Septal , Telemetria
8.
Catheter Cardiovasc Interv ; 92(5): 945-953, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29520970

RESUMO

OBJECTIVES: To explore the rate, the determinants of success, and the hemodynamic impact of balloon postdilatation (BPD) of self-expanding transcatheter heart valves (SE-THVs) BACKGROUND: BPD is commonly used to optimize valve expansion and reduce paravalvular leakage (PVL) after transcatheter aortic valve implantation (TAVI) without clearly knowing its hemodynamic benefits. METHODS: Patients (n = 307) who received a SE-THV were stratified according to whether a BPD was performed or not. Patients who received BPD were stratified according to the severity of PVL remaining after BPD into two groups: Successful BPD (≤mild PVL + BPD) and Failed BPD (moderate-severe PVL + BPD). RESULTS: BPD was performed in 121 patients (39.4%) and was successful in 106 patients (87.6% of attempts). A ratio of the postdilatation balloon diameter to the annulus diameter ≤0.95 was an independent predictor of BPD failure (OR: 10.72 [2.02-56.76], P = .005). Peak transvalvular pressure gradient (PG) was lower in the Successful BPD group (14[12-22] mm Hg) than in the Failed BPD group (18[16-23] mm Hg, P = .029), and did not rise in either group during follow-up (median [IQR], 364[161-739] days). CONCLUSION: BPD was performed in 39% of patients who received a SE-THV, and was successful in the majority of attempts. BPD failure was more likely in patients with a small postdilatation balloon-to-annulus diameter ratio. Effective BPD improved THV hemodynamic performance, and this was maintained in the intermediate-term post-TAVI.


Assuntos
Insuficiência da Valva Aórtica/prevenção & controle , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Valvuloplastia com Balão , Próteses Valvulares Cardíacas , Hemodinâmica , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Brasil , Feminino , Humanos , Masculino , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
9.
Circ J ; 82(7): 1943-1950, 2018 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-29760325

RESUMO

BACKGROUND: The clinical robustness of contrast-videodensitometric (VD) assessment of aortic regurgitation (AR) after transcatheter aortic valve implantation (TAVI) has been demonstrated. Correct acquisition of aortic root angiography for VD assessment, however, is hampered by the opacified descending aorta and by individual anatomic peculiarities. The aim of this study was to use preprocedural multi-slice computed tomography (MSCT) to optimize the angiographic projection in order to improve the feasibility of VD assessment.Methods and Results:In 92 consecutive patients, post-TAVI AR (i.e., left ventricular outflow tract [LVOT] AR) was assessed on aortic root angiograms using VD software. The patients were divided into 2 groups: The first group of 54 patients was investigated prior to the introduction of the standardized acquisition protocol; the second group of 38 consecutive patients after implementation of the standardized acquisition protocol, involving MSCT planning of the optimal angiographic projection. Optimal projection planning has dramatically improved the feasibility of VD assessment from 57.4% prior to the standardized acquisition protocol, to 100% after the protocol was implemented. In 69 analyzable aortograms (69/92; 75%), LVOT-AR ranged from 3% to 28% with a median of 12%. Inter-observer agreement was high (mean difference±SD, 1±2%), and the 2 observers' measurements were highly correlated (r=0.94, P<0.0001). CONCLUSIONS: Introduction of computed tomography-guided angiographic image acquisition has significantly improved the analyzability of the angiographic VD assessment of post-TAVI AR.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Aortografia/métodos , Tomografia Computadorizada por Raios X/métodos , Substituição da Valva Aórtica Transcateter/métodos , Insuficiência da Valva Aórtica/diagnóstico , Humanos , Variações Dependentes do Observador , Raios X
10.
Circ J ; 82(9): 2317-2325, 2018 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-29973472

RESUMO

BACKGROUND: We investigated the relationship between intraprocedural angiographic and echocardiographic AR severity after TAVI, and the clinical robustness of angiographic assessment. Methods and Results: In 74 consecutive patients, the echocardiographic circumferential extent (CE) of the paravalvular regurgitant jet was retrospectively measured and graded based on the VARC-2 cut-points; and angiographic post-TAVI AR was retrospectively quantified using contrast videodensitometry (VD) software that calculates the ratio of the contrast time-density integral in the LV outflow tract to that in the ascending aorta (LVOT-AR). Seventy-four echocardiograms immediately after TAVI were analyzable, while 51 aortograms were analyzable for VD. These 51 echocardiograms and VD were evaluated. Median LVOT-AR across the echocardiographic AR grades was as follows: none-trace, 0.07 (IQR, 0.05-0.11); mild, 0.12 (IQR, 0.09-0.15); and moderate, 0.17 (IQR, 0.15-0.22; P<0.05 for none-trace vs. mild, and mild vs. moderate). LVOT-AR strongly correlated with %CE (r=0.72, P<0.0001). At 1 year, the rate of the composite end-point of all-cause death or HF re-hospitalization was significantly higher in >mild AR patients compared with no-mild AR on intra-procedural echocardiography (41.5% vs. 12.4%, P=0.03) as well as in patients with LVOT-AR >0.17 compared with LVOT-AR ≤0.17 (59.5% vs. 16.6%, P=0.03). CONCLUSIONS: VD (LVOT-AR) has good intra-procedural inter-technique consistency and clinical robustness. Greater than mild post-TAVI AR, but not mild post-TAVI AR, is associated with late mortality.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Aortografia/métodos , Ecocardiografia Transesofagiana/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/mortalidade , Feminino , Seguimentos , Humanos , Masculino , Readmissão do Paciente , Prognóstico , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA