Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Magn Reson Imaging ; 59(4): 1242-1255, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37452574

RESUMO

BACKGROUND: Increased afterload in aortic stenosis (AS) induces left ventricle (LV) remodeling to preserve a normal ejection fraction. This compensatory response can become maladaptive and manifest with motion abnormality. It is a clinical challenge to identify contractile and relaxation dysfunction during early subclinical stage to prevent irreversible deterioration. PURPOSE: To evaluate the changes of regional wall dynamics in 3D + time domain as remodeling progresses in AS. STUDY TYPE: Retrospective. POPULATION: A total of 31 AS patients with reduced and preserved ejection fraction (14 AS_rEF: 7 male, 66.5 [7.8] years old; 17 AS_pEF: 12 male, 67.0 [6.0] years old) and 15 healthy (6 male, 61.0 [7.0] years old). FIELD STRENGTH/SEQUENCE: 1.5 T Magnetic resonance imaging/steady state free precession and late-gadolinium enhancement sequences. ASSESSMENT: Individual LV models were reconstructed in 3D + time domain and motion metrics including wall thickening (TI), dyssynchrony index (DI), contraction rate (CR), and relaxation rate (RR) were automatically extracted and associated with the presence of scarring and remodeling. STATISTICAL TESTS: Shapiro-Wilk: data normality; Kruskal-Wallis: significant difference (P < 0.05); ICC and CV: variability; Mann-Whitney: effect size. RESULTS: AS_rEF group shows distinct deterioration of cardiac motions compared to AS_pEF and healthy groups (TIAS_rEF : 0.92 [0.85] mm, TIAS_pEF : 5.13 [1.99] mm, TIhealthy : 3.61 [1.09] mm, ES: 0.48-0.83; DIAS_rEF : 17.11 [7.89]%, DIAS_pEF : 6.39 [4.04]%, DIhealthy : 5.71 [1.87]%, ES: 0.32-0.85; CRAS_rEF : 8.69 [6.11] mm/second, CRAS_pEF : 16.48 [6.70] mm/second, CRhealthy : 10.82 [4.57] mm/second, ES: 0.29-0.60; RRAS_rEF : 8.45 [4.84] mm/second; RRAS_pEF : 13.49 [8.56] mm/second, RRhealthy : 9.31 [2.48] mm/second, ES: 0.14-0.43). The difference in the motion metrics between healthy and AS_pEF groups were insignificant (P-value = 0.16-0.72). AS_rEF group was dominated by eccentric hypertrophy (47.1%) with concomitant scarring. Conversely, AS_pEF group was dominated by concentric remodeling and hypertrophy (71.4%), which could demonstrate hyperkinesia with slight wall dyssynchrony than healthy. Dysfunction of LV mechanics corresponded to the presence of myocardial scarring (54.9% in AS), which reverted the compensatory mechanisms initiated and performed by LV remodeling. DATA CONCLUSION: The proposed 3D + time modeling technique may distinguish regional motion abnormalities between AS_pEF, AS_rEF, and healthy cohorts, aiding clinical diagnosis and monitoring of AS progression. Subclinical myocardial dysfunction is evident in early AS despite of normal EF. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY: Stage 1.


Assuntos
Estenose da Valva Aórtica , Meios de Contraste , Humanos , Masculino , Criança , Estudos Retrospectivos , Cicatriz , Gadolínio , Imageamento por Ressonância Magnética , Estenose da Valva Aórtica/diagnóstico por imagem , Hipertrofia , Função Ventricular Esquerda , Volume Sistólico , Remodelação Ventricular
2.
Clin Gastroenterol Hepatol ; 18(4): 945-953.e2, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31442603

RESUMO

BACKGROUND & AIMS: HepaFat-Scan is a magnetic resonance imaging-based method for quantification of hepatic steatosis by volumetric liver fat fraction (VLFF) measurement. We aimed to validate VLFF and to compare it with controlled attenuation parameter (CAP) for determination of hepatic steatosis grade in patients with NAFLD, using histopathology and stereologic analyses of biopsies as the reference standard. METHODS: We performed a prospective study of consecutive adults with NAFLD who were scheduled for a liver biopsy at a tertiary hospital in Malaysia. Patients underwent VLFF and CAP measurements on the same day as their liver biopsy. Histopathology analyses of liver biopsy specimens were reported according to the Nonalcoholic Steatohepatitis Clinical Research Network scoring system. Stereologic analysis was performed using grid-point counting method combined with the Delesse principle. RESULTS: We analyzed data from 97 patients (mean age 57.0 ± 10.1 years; 44.33% male; 91.8% obese; 95.9% centrally obese). Based on histopathology analysis, the area under receiver operating characteristic curve (AUROC) for VLFF in detection of steatosis grade ≥S2 was 0.92 and for CAP the AUROC was 0.65 (P < .001). Based on stereological analysis, the AUROC for VLFF for detection of steatosis grade ≥S2 was 0.92 and for CAP the AUROC was 0.63, (P = .002); for identification of steatosis grade S3, the AUROC for VLFF was 0.92 and for CAP the AUROC was 0.68 (P < .001). CONCLUSIONS: In a prospective study of patients with NAFLD undergoing liver biopsy analysis, we found VLFF to more accurately determine grade of hepatic steatosis than CAP.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatopatia Gordurosa não Alcoólica , Adulto , Área Sob a Curva , Biópsia , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Estudos Prospectivos , Curva ROC
3.
Magn Reson Med ; 81(2): 1385-1398, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30230606

RESUMO

PURPOSE: To evaluate a 2D-4D registration-cum-segmentation framework for the delineation of left ventricle (LV) in late gadolinium enhanced (LGE) MRI and for the localization of infarcts in patient-specific 3D LV models. METHODS: A 3-step framework was proposed, consisting of: (1) 3D LV model reconstruction from motion-corrected 4D cine-MRI; (2) Registration of 2D LGE-MRI with 4D cine-MRI; (3) LV contour extraction from the intersection of LGE slices with the LV model. The framework was evaluated against cardiac MRI data from 27 patients scanned within 6 months after acute myocardial infarction. We compared the use of local Pearson's correlation (LPC) and normalized mutual information (NMI) as similarity measures for the registration. The use of 2 and 6 long-axis (LA) cine-MRI scans was also compared. The accuracy of the framework was evaluated using manual segmentation, and the interobserver variability of the scar volume derived from the segmented LV was determined using Bland-Altman analysis. RESULTS: LPC outperformed NMI as a similarity measure for the proposed framework using 6 LA scans, with Hausdorrf distance (HD) of 1.19 ± 0.53 mm versus 1.51 ± 2.01 mm (endocardial) and 1.21 ± 0.48 mm versus 1.46 ± 1.78 mm (epicardial), respectively. Segmentation using 2 LA scans was comparable to 6 LA scans with a HD of 1.23 ± 0.70 mm (endocardial) and 1.25 ± 0.74 mm (epicardial). The framework yielded a lower interobserver variability in scar volumes compared with manual segmentation. CONCLUSION: The framework showed high accuracy and robustness in delineating LV in LGE-MRI and allowed for bidirectional mapping of information between LGE- and cine-MRI scans, crucial in personalized model studies for treatment planning.


Assuntos
Gadolínio/química , Ventrículos do Coração/diagnóstico por imagem , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Infarto do Miocárdio/diagnóstico por imagem , Algoritmos , Simulação por Computador , Humanos , Processamento de Imagem Assistida por Computador , Movimento (Física) , Variações Dependentes do Observador , Prognóstico , Planejamento da Radioterapia Assistida por Computador , Reprodutibilidade dos Testes
4.
J Magn Reson Imaging ; 49(4): 1006-1019, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30211445

RESUMO

BACKGROUND: Existing clinical diagnostic and assessment methods could be improved to facilitate early detection and treatment of cardiac dysfunction associated with acute myocardial infarction (AMI) to reduce morbidity and mortality. PURPOSE: To develop 3D personalized left ventricular (LV) models and thickening assessment framework for assessing regional wall thickening dysfunction and dyssynchrony in AMI patients. STUDY TYPE: Retrospective study, diagnostic accuracy. SUBJECTS: Forty-four subjects consisting of 15 healthy subjects and 29 AMI patients. FIELD STRENGTH/SEQUENCE: 1.5T/steady-state free precession cine MRI scans; LGE MRI scans. ASSESSMENT: Quantitative thickening measurements across all cardiac phases were correlated and validated against clinical evaluation of infarct transmurality by an experienced cardiac radiologist based on the American Heart Association (AHA) 17-segment model. STATISTICAL TEST: Nonparametric 2-k related sample-based Kruskal-Wallis test; Mann-Whitney U-test; Pearson's correlation coefficient. RESULTS: Healthy LV wall segments undergo significant wall thickening (P < 0.05) during ejection and have on average a thicker wall (8.73 ± 1.01 mm) compared with infarcted wall segments (2.86 ± 1.11 mm). Myocardium with thick infarct (ie, >50% transmurality) underwent remarkable wall thinning during contraction (thickening index [TI] = 1.46 ± 0.26 mm) as opposed to healthy myocardium (TI = 4.01 ± 1.04 mm). For AMI patients, LV that showed signs of thinning were found to be associated with a significantly higher percentage of dyssynchrony as compared with healthy subjects (dyssynchrony index [DI] = 15.0 ± 5.0% vs. 7.5 ± 2.0%, P < 0.01). Also, a strong correlation was found between our TI and left ventricular ejection fraction (LVEF) (r = 0.892, P < 0.01), and moderate correlation between DI and LVEF (r = 0.494, P < 0.01). DATA CONCLUSION: The extracted regional wall thickening and DIs are shown to be strongly correlated with infarct severity, therefore suggestive of possible practical clinical utility. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:1006-1019.


Assuntos
Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética , Infarto do Miocárdio/diagnóstico por imagem , Disfunção Ventricular Esquerda/diagnóstico por imagem , Doença Aguda , Idoso , Algoritmos , Simulação por Computador , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Informática Médica , Pessoa de Meia-Idade , Miocárdio/patologia , Variações Dependentes do Observador , Reconhecimento Automatizado de Padrão , Estudos Retrospectivos , Função Ventricular Esquerda
5.
J Magn Reson Imaging ; 48(1): 140-152, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29316024

RESUMO

BACKGROUND: Left ventricle (LV) structure and functions are the primary assessment performed in most clinical cardiac MRI protocols. Fully automated LV segmentation might improve the efficiency and reproducibility of clinical assessment. PURPOSE: To develop and validate a fully automated neural network regression-based algorithm for segmentation of the LV in cardiac MRI, with full coverage from apex to base across all cardiac phases, utilizing both short axis (SA) and long axis (LA) scans. STUDY TYPE: Cross-sectional survey; diagnostic accuracy. SUBJECTS: In all, 200 subjects with coronary artery diseases and regional wall motion abnormalities from the public 2011 Left Ventricle Segmentation Challenge (LVSC) database; 1140 subjects with a mix of normal and abnormal cardiac functions from the public Kaggle Second Annual Data Science Bowl database. FIELD STRENGTH/SEQUENCE: 1.5T, steady-state free precession. ASSESSMENT: Reference standard data generated by experienced cardiac radiologists. Quantitative measurement and comparison via Jaccard and Dice index, modified Hausdorff distance (MHD), and blood volume. STATISTICAL TESTS: Paired t-tests compared to previous work. RESULTS: Tested against the LVSC database, we obtained 0.77 ± 0.11 (Jaccard index) and 1.33 ± 0.71 mm (MHD), both metrics demonstrating statistically significant improvement (P < 0.001) compared to previous work. Tested against the Kaggle database, the signed difference in evaluated blood volume was +7.2 ± 13.0 mL and -19.8 ± 18.8 mL for the end-systolic (ES) and end-diastolic (ED) phases, respectively, with a statistically significant improvement (P < 0.001) for the ED phase. DATA CONCLUSION: A fully automated LV segmentation algorithm was developed and validated against a diverse set of cardiac cine MRI data sourced from multiple imaging centers and scanner types. The strong performance overall is suggestive of practical clinical utility. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética , Miocárdio/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Automação , Criança , Pré-Escolar , Doença da Artéria Coronariana/diagnóstico por imagem , Estudos Transversais , Diástole , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Lactente , Recém-Nascido , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Redes Neurais de Computação , Reconhecimento Automatizado de Padrão/métodos , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Processos Estocásticos , Sístole , Adulto Jovem
6.
J Magn Reson Imaging ; 45(2): 525-534, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27418150

RESUMO

PURPOSE: To propose a cardiac motion tracking model that evaluates wall motion abnormality in postmyocardial infarction patients. Correlation between the motion parameter of the model and left ventricle (LV) function was also determined. MATERIALS AND METHODS: Twelve male patients with post-ST elevation myocardial infarction (post-STEMI) and 10 healthy controls of the same gender were recruited to undergo cardiac magnetic resonance imaging (MRI) using a 1.5T scanner. Using an infarct-specific LV division approach, the late gadolinium enhancement (LGE) MRI images were used to divide the LV on the tagged MRI images into infarct, adjacent, and remote sectors. Motion tracking was performed using the infarct-specific two-parameter empirical deformable model (TPEDM). The match quality was defined as the position error computed using root-mean-square (RMS) distance between the estimated and expert-verified tag intersections. The position errors were compared with the ones from our previously published fixed-sector TPEDM. Cine MRI images were used to calculate regional ejection fraction (REF). Correlation between the end-systolic contraction parameter (αES ) with REF was determined. RESULTS: The position errors in the proposed model were significantly lower than the fixed-sector model (P < 0.01). The median position errors were 0.82 mm versus 1.23 mm. The αES correlates significantly with REF (r = 0.91, P < 0.01). CONCLUSION: The infarct-specific TPEDM combines the morphological and functional information from LGE and tagged MRI images. It was shown to outperform the fixed-sector model in assessing regional LV dysfunction. The significant correlation between αES and REF added prognostic value because it indicated an impairment of cardiac function with the increase of infarct transmurality. LEVEL OF EVIDENCE: 3 J. Magn. Reson. Imaging 2017;45:525-534.


Assuntos
Imagem Cinética por Ressonância Magnética/métodos , Modelos Cardiovasculares , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Técnica de Subtração , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Simulação por Computador , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Movimento , Imagem Multimodal/métodos , Infarto do Miocárdio/complicações , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Disfunção Ventricular Esquerda/etiologia
7.
Heart Lung Circ ; 22(4): 305-8, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22921797

RESUMO

Pericardial cysts are uncommon mediastinal lesions that are usually congenital in origin. Patients are usually asymptomatic and the cysts are generally discovered on routine radiography for unrelated purposes. This case illustrates a symptomatic presentation of a haemorrhagic pericardial cyst in which radiographic, echocardiographic and multislice (MRI and CT) imaging were performed. The imaging findings were not typical of pericardial cysts leading to a diagnostic quandary despite the varied imaging techniques. In conclusion, it is important to appreciate that the imaging findings of pericardial cysts can be varied. Radiologists and clinicians alike should be aware of this variability.


Assuntos
Cisto Mediastínico/diagnóstico por imagem , Ecocardiografia/métodos , Humanos , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/métodos
8.
J Cardiovasc Transl Res ; 16(5): 1110-1122, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37022611

RESUMO

Left ventricular adaptations can be a complex process under the influence of aortic stenosis (AS) and comorbidities. This study proposed and assessed the feasibility of using a motion-corrected personalized 3D + time LV modeling technique to evaluate the adaptive and maladaptive LV response to aid treatment decision-making. A total of 22 AS patients were analyzed and compared against 10 healthy subjects. The 3D + time analysis showed a highly distinct and personalized pattern of remodeling in individual AS patients which is associated with comorbidities and fibrosis. Patients with AS alone showed better wall thickening and synchrony than those comorbid with hypertension. Ischemic heart disease in AS caused impaired wall thickening and synchrony and systolic function. Apart from showing significant correlations to echocardiography and clinical MRI measurements (r: 0.70-0.95; p < 0.01), the proposed technique helped in detecting subclinical and subtle LV dysfunction, providing a better approach to evaluate AS patients for specific treatment, surgical planning, and follow-up recovery.


Assuntos
Estenose da Valva Aórtica , Disfunção Ventricular Esquerda , Humanos , Função Ventricular Esquerda/fisiologia , Ventrículos do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Ecocardiografia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia
9.
Phys Med ; 78: 137-149, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33007738

RESUMO

Differential diagnosis of hypertensive heart disease (HHD) and hypertrophic cardiomyopathy (HCM) is clinically challenging but important for treatment management. This study aims to phenotype HHD and HCM in 3D + time domain by using a multiparametric motion-corrected personalized modeling algorithm and cardiac magnetic resonance (CMR). 44 CMR data, including 12 healthy, 16 HHD and 16 HCM cases, were examined. Multiple CMR phenotype data consisting of geometric and dynamic variables were extracted globally and regionally from the models over a full cardiac cycle for comparison against healthy models and clinical reports. Statistical classifications were used to identify the distinctive characteristics and disease subtypes with overlapping functional data, providing insights into the challenges for differential diagnosis of both types of disease. While HCM is characterized by localized extreme hypertrophy of the LV, wall thickening/contraction/strain was found to be normal and in sync, though it was occasionally exaggerated at normotrophic/less severely hypertrophic regions during systole to preserve the overall ejection fraction (EF) and systolic functionality. Additionally, we observed that hypertrophy in HHD could also be localized, although at less extreme conditions (i.e. more concentric). While fibrosis occurs mostly in those HCM cases with aortic obstruction, only minority of HHD patients were found affected by fibrosis. We demonstrate that subgroups of HHD (i.e. preserved and reduced EF: HHDpEF & HHDrEF) have different 3D + time CMR characteristics. While HHDpEF has cardiac functions in normal range, dilation and heart failure are indicated in HHDrEF as reflected by low LV wall thickening/contraction/strain and synchrony, as well as much reduced EF.


Assuntos
Cardiomiopatia Hipertrófica , Cardiopatias , Hipertensão , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Imagem Cinética por Ressonância Magnética
10.
Int J Numer Method Biomed Eng ; 36(1): e3291, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31799767

RESUMO

Myocardial infarct extension, a process involving the enlargement of infarct and border zone, leads to progressive degeneration of left ventricular (LV) function and eventually gives rise to heart failure. Despite carrying a high risk, the causation of infarct extension is still a subject of much speculation. In this study, patient-specific LV models were developed to investigate the correlation between infarct extension and impaired regional mechanics. Subsequently, sensitivity analysis was performed to examine the causal factors responsible for the impaired regional mechanics observed in regions surrounding the infarct and border zone. From our simulations, fibre strain, fibre stress and fibre stress-strain loop (FSSL) were the key biomechanical variables affected in these regions. Among these variables, only FSSL was correlated with infarct extension, as reflected in its work density dissipation (WDD) index value, with high WDD indices recorded at regions with infarct extension. Impaired FSSL is caused by inadequate contraction force generation during the isovolumic contraction and ejection phases. Our further analysis revealed that the inadequacy in contraction force generation is not necessarily due to impaired myocardial intrinsic contractility, but at least in part, due to inadequate muscle fibre stretch at end-diastole, which depresses the ability of myocardium to generate adequate contraction force in the subsequent systole (according to the Frank-Starling law). Moreover, an excessively stiff infarct may cause its neighbouring myocardium to be understretched at end-diastole, subsequently depressing the systolic contractile force of the neighbouring myocardium, which was found to be correlated with infarct extension.


Assuntos
Diástole/fisiologia , Infarto do Miocárdio/fisiopatologia , Miocárdio/patologia , Adulto , Idoso , Simulação por Computador , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Sarcômeros/fisiologia , Estresse Mecânico , Sístole/fisiologia
11.
Quant Imaging Med Surg ; 9(1): 107-114, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30788252

RESUMO

Current visualization techniques of complex congenital heart disease (CHD) are unable to provide comprehensive visualization of the anomalous cardiac anatomy as the medical datasets can essentially only be viewed from a flat, two-dimensional (2D) screen. Three-dimensional (3D) printing has therefore been used to replicate patient-specific hearts in 3D views based on medical imaging datasets. This technique has been shown to have a positive impact on the preoperative planning of corrective surgery, patient-doctor communication, and the learning experience of medical students. However, 3D printing is often costly, and this impedes the routine application of this technology in clinical practice. This technical note aims to investigate whether reducing 3D printing costs can have any impact on the clinical value of the 3D-printed heart models. Low-cost and a high-cost 3D-printed models based on a selected case of CHD were generated with materials of differing cost. Quantitative assessment of dimensional accuracy of the cardiac anatomy and pathology was compared between the 3D-printed models and the original cardiac computed tomography (CT) images with excellent correlation (r=0.99). Qualitative evaluation of model usefulness showed no difference between the two models in medical applications.

12.
Quant Imaging Med Surg ; 9(4): 552-564, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31143647

RESUMO

BACKGROUND: High delivery rate is an important factor in optimizing contrast medium administration in coronary computed tomography angiography (CCTA). A personalized contrast volume calculation algorithm incorporating high iodine delivery rate (IDR) can reduce total iodine dose (TID) and produce optimal vessel contrast enhancement (VCE) in low tube voltage CCTA. In this study, we developed and validated an algorithm for calculating the volume of contrast medium delivered at a high rate for patients undergoing retrospectively ECG-gated CCTA with low tube voltage protocol. METHODS: The algorithm for an IDR of 2.22 gI·s-1 was developed based on the relationship between VCE and contrast volume in 141 patients; test bolus parameters and characteristics in 75 patients; and, tube voltage in a phantom study. The algorithm was retrospectively tested in 45 patients who underwent retrospectively ECG-gated CCTA with a 100 kVp protocol. Image quality, TID and radiation dose exposure were compared with those produced using the 120 kVp and routine contrast protocols. RESULTS: Age, sex, body surface area (BSA) and peak contrast enhancement (PCE) were significant predictors for VCE (P<0.05). A strong linear correlation was observed between VCE and contrast volume (r=0.97, P<0.05). The 100-to-120 kVp contrast enhancement conversion factor (Ec) was calculated at 0.81. Optimal VCE (250 to 450 HU) and diagnostic image quality were obtained with significant reductions in TID (32.1%) and radiation dose (38.5%) when using 100 kVp and personalized contrast volume calculation algorithm compared with 120 kVp and routine contrast protocols (P<0.05). CONCLUSIONS: The proposed algorithm could significantly reduce TID and radiation exposure while maintaining optimal VCE and image quality in CCTA with 100 kVp protocol.

13.
Med Biol Eng Comput ; 56(6): 1053-1062, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29147835

RESUMO

In this paper, we develop and validate an open source, fully automatic algorithm to localize the left ventricular (LV) blood pool centroid in short axis cardiac cine MR images, enabling follow-on automated LV segmentation algorithms. The algorithm comprises four steps: (i) quantify motion to determine an initial region of interest surrounding the heart, (ii) identify potential 2D objects of interest using an intensity-based segmentation, (iii) assess contraction/expansion, circularity, and proximity to lung tissue to score all objects of interest in terms of their likelihood of constituting part of the LV, and (iv) aggregate the objects into connected groups and construct the final LV blood pool volume and centroid. This algorithm was tested against 1140 datasets from the Kaggle Second Annual Data Science Bowl, as well as 45 datasets from the STACOM 2009 Cardiac MR Left Ventricle Segmentation Challenge. Correct LV localization was confirmed in 97.3% of the datasets. The mean absolute error between the gold standard and localization centroids was 2.8 to 4.7 mm, or 12 to 22% of the average endocardial radius. Graphical abstract Fully automated localization of the left ventricular blood pool in short axis cardiac cine MR images.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Algoritmos , Bases de Dados Factuais , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos
14.
Br J Radiol ; 91(1088): 20170874, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29493261

RESUMO

OBJECTIVE: This study aimed (1) to perform a systematic review on scanning parameters and contrast medium (CM) reduction methods used in prospectively electrocardiography (ECG-triggered low tube voltage coronary CT angiography (CCTA), (2) to compare the achievable dose reduction and image quality and (3) to propose appropriate scanning techniques and CM administration methods. METHODS: A systematic search was performed in PubMed, the Cochrane library, CINAHL, Web of Science, ScienceDirect and Scopus, where 20 studies were selected for analysis of scanning parameters and CM reduction methods. RESULTS: The mean effective dose (HE) ranged from 0.31 to 2.75 mSv at 80 kVp, 0.69 to 6.29 mSv at 100 kVp and 1.53 to 10.7 mSv at 120 kVp. Radiation dose reductions of 38 to 83% at 80 kVp and 3 to 80% at 100 kVp could be achieved with preserved image quality. Similar vessel contrast enhancement to 120 kVp could be obtained by applying iodine delivery rate (IDR) of 1.35 to 1.45 g s-1 with total iodine dose (TID) of between 10.9 and 16.2 g at 80 kVp and IDR of 1.08 to 1.70 g s-1 with TID of between 18.9 and 20.9 g at 100 kVp. CONCLUSION: This systematic review found that radiation doses could be reduced to a rate of 38 to 83% at 80 kVp, and 3 to 80% at 100 kVp without compromising the image quality. Advances in knowledge: The suggested appropriate scanning parameters and CM reduction methods can be used to help users in achieving diagnostic image quality with reduced radiation dose.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Eletrocardiografia , Humanos , Doses de Radiação
15.
PLoS One ; 12(4): e0175781, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28419125

RESUMO

OBJECTIVES: To investigate: (1) the variability of mammographic compression parameters amongst Asian women; and (2) the effects of reducing compression force on image quality and mean glandular dose (MGD) in Asian women based on phantom study. METHODS: We retrospectively collected 15818 raw digital mammograms from 3772 Asian women aged 35-80 years who underwent screening or diagnostic mammography between Jan 2012 and Dec 2014 at our center. The mammograms were processed using a volumetric breast density (VBD) measurement software (Volpara) to assess compression force, compression pressure, compressed breast thickness (CBT), breast volume, VBD and MGD against breast contact area. The effects of reducing compression force on image quality and MGD were also evaluated based on measurement obtained from 105 Asian women, as well as using the RMI156 Mammographic Accreditation Phantom and polymethyl methacrylate (PMMA) slabs. RESULTS: Compression force, compression pressure, CBT, breast volume, VBD and MGD correlated significantly with breast contact area (p<0.0001). Compression parameters including compression force, compression pressure, CBT and breast contact area were widely variable between [relative standard deviation (RSD)≥21.0%] and within (p<0.0001) Asian women. The median compression force should be about 8.1 daN compared to the current 12.0 daN. Decreasing compression force from 12.0 daN to 9.0 daN increased CBT by 3.3±1.4 mm, MGD by 6.2-11.0%, and caused no significant effects on image quality (p>0.05). CONCLUSIONS: Force-standardized protocol led to widely variable compression parameters in Asian women. Based on phantom study, it is feasible to reduce compression force up to 32.5% with minimal effects on image quality and MGD.


Assuntos
Mama/diagnóstico por imagem , Mamografia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Ásia , Povo Asiático , Densidade da Mama , Feminino , Humanos , Mamografia/instrumentação , Pessoa de Meia-Idade , Imagens de Fantasmas , Estudos Retrospectivos , Software
16.
Br J Radiol ; 89(1066): 20160258, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27452264

RESUMO

OBJECTIVE: To investigate the sensitivity and robustness of a volumetric breast density (VBD) measurement system to errors in the imaging physics parameters including compressed breast thickness (CBT), tube voltage (kVp), filter thickness, tube current-exposure time product (mAs), detector gain, detector offset and image noise. METHODS: 3317 raw digital mammograms were processed with Volpara(®) (Matakina Technology Ltd, Wellington, New Zealand) to obtain fibroglandular tissue volume (FGV), breast volume (BV) and VBD. Errors in parameters including CBT, kVp, filter thickness and mAs were simulated by varying them in the Digital Imaging and Communications in Medicine (DICOM) tags of the images up to ±10% of the original values. Errors in detector gain and offset were simulated by varying them in the Volpara configuration file up to ±10% from their default values. For image noise, Gaussian noise was generated and introduced into the original images. RESULTS: Errors in filter thickness, mAs, detector gain and offset had limited effects on FGV, BV and VBD. Significant effects in VBD were observed when CBT, kVp, detector offset and image noise were varied (p < 0.0001). Maximum shifts in the mean (1.2%) and median (1.1%) VBD of the study population occurred when CBT was varied. CONCLUSION: Volpara was robust to expected clinical variations, with errors in most investigated parameters giving limited changes in results, although extreme variations in CBT and kVp could lead to greater errors. ADVANCES IN KNOWLEDGE: Despite Volpara's robustness, rigorous quality control is essential to keep the parameter errors within reasonable bounds. Volpara appears robust within those bounds, albeit for more advanced applications such as tracking density change over time, it remains to be seen how accurate the measures need to be.


Assuntos
Densidade da Mama , Mamografia/métodos , Feminino , Humanos , Física , Controle de Qualidade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Sensibilidade e Especificidade
17.
PLoS One ; 11(8): e0161543, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27552224

RESUMO

OBJECTIVES: This study aimed to measure the absorbed doses in selected organs for prospectively ECG-triggered coronary computed tomography angiography (CCTA) using five different generations CT scanners in a female adult anthropomorphic phantom and to estimate the effective dose (HE). MATERIALS AND METHODS: Prospectively ECG-triggered CCTA was performed using five commercially available CT scanners: 64-detector-row single source CT (SSCT), 2 × 32-detector-row-dual source CT (DSCT), 2 × 64-detector-row DSCT and 320-detector-row SSCT scanners. Absorbed doses were measured in 34 organs using pre-calibrated optically stimulated luminescence dosimeters (OSLDs) placed inside a standard female adult anthropomorphic phantom. HE was calculated from the measured organ doses and compared to the HE derived from the air kerma-length product (PKL) using the conversion coefficient of 0.014 mSv∙mGy-1∙cm-1 for the chest region. RESULTS: Both breasts and lungs received the highest radiation dose during CCTA examination. The highest HE was received from 2 × 32-detector-row DSCT scanner (6.06 ± 0.72 mSv), followed by 64-detector-row SSCT (5.60 ± 0.68 and 5.02 ± 0.73 mSv), 2 × 64-detector-row DSCT (1.88 ± 0.25 mSv) and 320-detector-row SSCT (1.34 ± 0.48 mSv) scanners. HE calculated from the measured organ doses were about 38 to 53% higher than the HE derived from the PKL-to-HE conversion factor. CONCLUSION: The radiation doses received from a prospectively ECG-triggered CCTA are relatively small and are depending on the scanner technology and imaging protocols. HE as low as 1.34 and 1.88 mSv can be achieved in prospectively ECG-triggered CCTA using 320-detector-row SSCT and 2 × 64-detector-row DSCT scanners.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doses de Radiação , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Feminino , Humanos , Especificidade de Órgãos/efeitos da radiação , Imagens de Fantasmas , Radiometria , Tomógrafos Computadorizados
18.
Medicine (Baltimore) ; 95(12): e3146, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27015196

RESUMO

The purpose of this study was to investigate the diagnostic efficacy of shearwave elastography (SWE) in differentiating between benign and malignant breast lesions.One hundred and fifty-nine lesions were assessed using B-mode ultrasound (US) and SWE parameters were recorded (Emax, Emean, Emin, Eratio, SD). SWE measurements were then correlated with histopathological diagnosis.The final sample contained 85 benign and 74 malignant lesions. The maximum stiffness (Emax) with a cutoff point of ≥ 56.0 kPa (based on ROC curves) provided sensitivity of 100.0%, specificity of 97.6%, positive predictive value (PPV) of 97.4%, and negative predictive value (NPV) of 100% in detecting malignant lesions. A cutoff of ≥80 kPa managed to downgrade 95.5% of the Breast Imaging-Reporting and Data System (BI-RADS) 4a lesions to BI-RADS 3, negating the need for biopsy. Using a combination of BI-RADS and SWE, the authors managed to improve the PPV from 2.3% to 50% in BI-RADS 4a lesions.SWE of the breast provides highly specific and sensitive quantitative values that are beneficial in the characterization of breast lesions. Our results showed that Emax is the most accurate value for differentiating benign from malignant lesions.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia Mamária/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Densidade da Mama , Neoplasias da Mama/patologia , Criança , Feminino , Humanos , Glândulas Mamárias Humanas/anormalidades , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Adulto Jovem
19.
Med Educ Online ; 20: 26185, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25697602

RESUMO

INTRODUCTION: The purpose of this study was to compare students' performance in the different clinical skills (CSs) assessed in the objective structured clinical examination. METHODS: Data for this study were obtained from final year medical students' exit examination (n=185). Retrospective analysis of data was conducted using SPSS. Means for the six CSs assessed across the 16 stations were computed and compared. RESULTS: Means for history taking, physical examination, communication skills, clinical reasoning skills (CRSs), procedural skills (PSs), and professionalism were 6.25±1.29, 6.39±1.36, 6.34±0.98, 5.86±0.99, 6.59±1.08, and 6.28±1.02, respectively. Repeated measures ANOVA showed there was a significant difference in the means of the six CSs assessed [F(2.980, 548.332)=20.253, p<0.001]. Pairwise multiple comparisons revealed significant differences between the means of the eight pairs of CSs assessed, at p<0.05. CONCLUSIONS: CRSs appeared to be the weakest while PSs were the strongest, among the six CSs assessed. Students' unsatisfactory performance in CRS needs to be addressed as CRS is one of the core competencies in medical education and a critical skill to be acquired by medical students before entering the workplace. Despite its challenges, students must learn the skills of clinical reasoning, while clinical teachers should facilitate the clinical reasoning process and guide students' clinical reasoning development.


Assuntos
Competência Clínica , Educação Médica/métodos , Avaliação Educacional/métodos , Estudantes de Medicina , Comunicação , Humanos , Papel do Médico , Reprodutibilidade dos Testes , Estudos Retrospectivos
20.
Iran J Radiol ; 12(1): e6878, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25793089

RESUMO

Coronary artery fistula (CAF) is a rare anomaly of the coronary artery. Patients with this condition are usually asymptomatic. However, cardiac failure may occur later in life due to progressive enlargement of the fistula. Diagnosis is traditionally made by echocardiogram and conventional angiogram. However with the advantage of new technologies such as computed tomography (CT) coronary angiography, the course and communications of these fistulae can be delineated non-invasively and with greater accuracy. We report a case of a left circumflex artery fistula to the coronary sinus which was suspected on echocardiogram and the diagnosis was clinched on ECG-gated CT.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA