Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Eur J Surg Oncol ; 43(4): 642-648, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27889196

RESUMO

BACKGROUND: Core needle biopsy (CNB) plays a crucial role as diagnostic tool for breast cancer (BC). The characterization of biomarkers status before surgical treatment is crucial when primary systemic therapy is a therapeutic option. The aim of this analysis was to report concordance between preoperative CNB and surgical specimen (SS) in evaluating biomarkers and molecular subtypes. METHODS: Data have been collected from a cohort of 101 patients affected by early BC treated at Careggi Florence University Hospital, between January 2014 and March 2015. The conformity between molecular subtype classification was tested using kappa (κ) test. RESULTS: Mean age was 57.5 years (range 29-86). There was concordance between the estrogen receptor (ER) assessment on CNB and SS in 95 cases (94.1%). Concordance of the progesterone receptor (PgR) assessment was observed in 89 cases (88.1%). Concordance for detecting immunohistochemistry-assessed BC molecular subtypes was 87.1% (κ = 0.78). Concerning Ki-67 evaluation, we report a concordance rate of 88.1% (κ = 0.68). The evaluation of luminal A plus luminal B/HER negative subgroup showed a κ-value of 0.65. CONCLUSIONS: CNB showed good accuracy in evaluating hormonal receptors status, HER2, and BC molecular subtypes. Evaluation of Ki67 status was less accurate than other biomarkers; therefore, we recommend that it should be detected both on CNB and SS samples, especially in hormonal positive HER2 negative tumors, in order to avoid a misclassification of tumor subtypes that could lead to an omission of potential effective systemic therapy.


Assuntos
Biomarcadores Tumorais/metabolismo , Neoplasias da Mama/metabolismo , Carcinoma Ductal de Mama/metabolismo , Carcinoma Lobular/metabolismo , Receptor ErbB-2/metabolismo , Receptores de Estrogênio/metabolismo , Receptores de Progesterona/metabolismo , Neoplasias de Mama Triplo Negativas/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia com Agulha de Grande Calibre , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Neoplasias da Mama/terapia , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/patologia , Carcinoma Ductal de Mama/terapia , Carcinoma Lobular/diagnóstico por imagem , Carcinoma Lobular/patologia , Carcinoma Lobular/terapia , Gerenciamento Clínico , Feminino , Humanos , Biópsia Guiada por Imagem , Imuno-Histoquímica , Antígeno Ki-67/metabolismo , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Neoplasias de Mama Triplo Negativas/diagnóstico por imagem , Neoplasias de Mama Triplo Negativas/patologia , Neoplasias de Mama Triplo Negativas/terapia , Ultrassonografia Mamária
2.
Eur J Surg Oncol ; 40(7): 859-64, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24612651

RESUMO

AIMS: Image-guided 14-gauge (G) core biopsy (CB) has been shown to be an accurate method providing histological diagnosis of breast lesions. The purpose of this study was to evaluate the reliability of image-guided 14-G CB in the diagnosis of phyllodes tumours (PT) reported as B3 category and its accuracy in distinguishing this lesion from fibroadenomas (FA). MATERIALS AND METHODS: The records of 10 000 image-guided 14-G CB of the breast performed from January 2001 to August 2011 at the Diagnostic Senology Unit of Careggi University Hospital were reviewed; 2554 (25.5%) were fibroepithelial lesions: 56 of them (2%) were diagnosed as PT and reported as B3 category. The database of the Pathological Anatomy Unit of Careggi University Hospital was then searched to verify the histological diagnosis after surgical excision. Fifty-one cases of PT diagnosed as B3 category in 51 women were included in the present study. RESULTS: Of the 51 cases of PT diagnosed as B3 category on 14-G CB, 39 (76.5%) lesions were confirmed as PT on SE (30, 4 and 5 as benign, borderline and malignant PT respectively) with a PPV of 76.5%. Twelve lesions (23.5%) were diagnosed as FA after surgical excision. CONCLUSIONS: Our study shows that 14-G CB is a valuable tool, in a preoperative setting, in diagnosing PT.


Assuntos
Biópsia com Agulha de Grande Calibre , Neoplasias da Mama/patologia , Fibroadenoma/patologia , Biópsia Guiada por Imagem/métodos , Tumor Filoide/patologia , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/cirurgia , Estudos de Coortes , Diagnóstico Diferencial , Feminino , Fibroadenoma/diagnóstico , Fibroadenoma/cirurgia , Hospitais Universitários , Humanos , Imuno-Histoquímica , Itália , Mastectomia/métodos , Invasividade Neoplásica/patologia , Estadiamento de Neoplasias , Tumor Filoide/diagnóstico , Tumor Filoide/cirurgia , Cuidados Pré-Operatórios/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos
3.
Eur J Surg Oncol ; 40(3): 277-81, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24388742

RESUMO

BACKGROUND: The dislocation of the malignant cells along the needle tract during breast cancer (BC) diagnosis has been demonstrated by several studies. However, the published experiences that relate the diagnostic technique with sentinel node (SN) involvement are few and controversial. The aim of our analysis was to evaluate the impact of different techniques for preoperative BC biopsy among prognostic factors of metastases occurrence in SN. MATERIALS AND METHODS: We reviewed the institutional clinical database of our Center. A total of 674 patients were diagnosed between February 1999 and December 2006 with invasive BC. SN metastases classification followed the 2002 American Joint Committee on Cancer (AJCC) TNM pathological staging: macrometastases, micrometastases, isolated tumor cells or negative. Only macrometastases and micrometastases were considered positive. Concerning fine-needle aspiration cytology, we used disposable needles of the size of 21-27 G. For percutaneous biopsy we used cutting needle type "tru-cut"; the Gauge needle ranged between 14 and 20. RESULTS: At univariate analysis of specific parameters using positive SN as outcome, percutaneous diagnostic technique did not affect significantly the SN positivity (p = 0.60). At multivariate models only central quadrant lesion (p = 0.005) and lymph vascular invasion (LVI) presence (p < 0.0001) maintained the statistical significance as risk factor for positive SN status. Polytomic logistics models showed that only LVI maintained the statistical significance both for prediction of micrometastases and macrometastases. CONCLUSIONS: Our analysis showed that different techniques used for BC diagnosis did not influence SN status.


Assuntos
Neoplasias da Mama/patologia , Carcinoma Intraductal não Infiltrante/secundário , Micrometástase de Neoplasia/patologia , Inoculação de Neoplasia , Biópsia de Linfonodo Sentinela/efeitos adversos , Biópsia de Linfonodo Sentinela/métodos , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Biópsia por Agulha Fina/efeitos adversos , Biópsia por Agulha Fina/métodos , Neoplasias da Mama/mortalidade , Neoplasias da Mama/cirurgia , Carcinoma Intraductal não Infiltrante/mortalidade , Carcinoma Intraductal não Infiltrante/cirurgia , Distribuição de Qui-Quadrado , Estudos de Coortes , Bases de Dados Factuais , Equipamentos Descartáveis , Feminino , Humanos , Imuno-Histoquímica , Incidência , Linfonodos/patologia , Metástase Linfática , Pessoa de Meia-Idade , Análise Multivariada , Invasividade Neoplásica , Recidiva Local de Neoplasia/epidemiologia , Recidiva Local de Neoplasia/patologia , Estadiamento de Neoplasias , Células Neoplásicas Circulantes/patologia , Prognóstico , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Medição de Risco , Análise de Sobrevida
4.
Breast ; 21(2): 159-64, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21944431

RESUMO

The purpose of this study was to evaluate the reliability of image-guided 14-gauge needle core biopsy in the diagnosis of radial scar without associated atypical epithelial proliferation, by comparison with definitive histological diagnosis on surgical excision. The records of 8792 consecutive image-guided 14-gauge needle core biopsy of the breast performed from January 1996 to December 2009 were reviewed. Forty-nine cases of radial scar without associated atypical epithelial proliferation were identified and compared with definitive histological diagnosis on surgical excision. The definitive histological diagnosis on surgical excision confirmed the results of image-guided 14-gauge needle core biopsy in 36 of 49 cases (73.5%), in 9 cases (18.3%) radial scar was associated with atypical epithelial proliferation, while 4 cases out of 49 cases were upgraded to carcinoma (3 cases of ductal carcinoma in situ and one case of invasive lobular carcinoma), with an underestimation rate of 8.2%. A diagnosis of radial scar without associated atypical epithelial proliferation on image-guided 14-gauge needle core biopsy does not exclude a malignancy on surgical excision; consequently during the multidisciplinary discussion further assessment by surgical excision or vacuum-assisted excision, as recently reported, needs to be considered to obtain a definitive histological diagnosis.


Assuntos
Doenças Mamárias/diagnóstico , Neoplasias da Mama/patologia , Mama/patologia , Carcinoma in Situ/patologia , Cicatriz/diagnóstico , Adulto , Idoso , Biópsia por Agulha , Doenças Mamárias/patologia , Proliferação de Células , Cicatriz/patologia , Células Epiteliais , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA