Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
JACC Case Rep ; 29(15): 102427, 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39157556

RESUMO

Atrial shunt devices are being implanted with increasing frequency, and there are potential concerns for subsequent procedures using transseptal access. A 79-year-old woman presented with progressive dyspnea of multifactorial etiology with already implanted atrial shunt device. Due to comorbidities, successful mitral-valve edge-to-edge repair was performed transseptally through the shunt device.

2.
JACC Case Rep ; 11: 101789, 2023 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-37077447

RESUMO

We report a complex case of a 53-year-old male patient with recurrent ischemic ventricular septal defect that had been occluded by a surgical patch. Treatment was accomplished utilizing a 3-dimensional-printed model for preprocedural planning. In the future, printing of 3-dimensional models could offer new therapeutic strategies on an individual level. (Level of Difficulty: Intermediate.).

3.
Thorac Cardiovasc Surg Rep ; 10(1): e1-e5, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33489712

RESUMO

Transcatheter aortic valve-in-valve implantation (VIV) is increasingly being used to successfully treat degenerated surgical aortic valve bioprostheses (SAVs). The new self-expanding transcatheter heart valve Allegra, from New Valve Technology with its special implantation mechanism, has proven its safety and feasibility for patients with degenerated SAVs, but it has never been used in the latest-generation sutureless SAV. To the best of our knowledge, this is the first description of the successful VIV of the Allegra prosthesis into a degenerated sutureless SAV, and the procedure yielded an excellent postinterventional hemodynamic results.

4.
Am Heart J ; 145(4): e17, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12679775

RESUMO

BACKGROUND: Stents coated with amorphous hypothrombogenic silicon carbide (a-SiC:H) have low restenosis rates in humans. Recurrence in a-SiC:H at mid-term follow-up has been shown to be similar to a stainless steel device. The long-term outcome, however, may be different. METHODS: Four hundred ninety-seven patients (63.4 +/- 9.8 years of age) received either the a-SiC:H-coated Tenax stent (Biotronik, Berlin, Germany) or the 316L Nir stent (Boston Scientific, Maple Grove, Minn). Lesions had to be covered with one stent only (diameter > or =2.8 mm, length <20 mm). Exclusion criteria comprised acute myocardial infarction and angiographic thrombus within the target vessel. Twenty-five of 497 (5%) patients were excluded for protocol violation. Clinical follow-up was completed in 450 of 472 (95.3%) and angiographic follow-up was completed in 365 of 472 (77.3%); 22 of 472 (4.7%) patients were lost to follow-up. RESULTS: Major adverse coronary events occurred in 28 of 233 (12%) of the Tenax recipients and in 31 of 217 (14.3%) of the Nir recipients (P =.50). Acute myocardial infarctions were less frequent in the Tenax recipients after > or =60 weeks. Premature target lesion revascularization was performed in 16 of 233 (6.9%) patients in the Tenax group and 11 of 217 (5.1%) (P =.54) patients in the Nir group. Coronary bypass operations were similar after Tenax or Nir stent deployment (3/233 [1.3%] vs 6/217 [2.8%], P =.43), as were deaths in 7 of 233 (3%) versus 8 of 217 (3.7%) (P =.88), respectively. CONCLUSIONS: Both stents had a low rate of major adverse coronary events at 81 +/- 12 weeks of follow-up, with no definite superiority of any of the devices.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Compostos Inorgânicos de Carbono , Doença das Coronárias/terapia , Compostos de Silício , Stents/normas , Idoso , Protocolos Clínicos , Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva
5.
J Interv Cardiol ; 16(4): 325-33, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-14562673

RESUMO

PURPOSE: Stents coated with hypothrombogenic silicon carbide (a-SiC:H) exhibited low restenosis rates in the rabbit and in an observational study in humans. Thus, the clinical and angiographic outcome was assessed in a large multicenter study. MATERIAL AND METHODS: Four hundred and ninety-seven patients (63.4 +/- 9.8 years) were randomized to either receive the a-SiC:H-coated Tenax stent or the stainless steel Nir stent. Lesions (diameter > or = 2.8 mm, length < 20 mm) were covered with one single stent. RESULTS: Fifty-one of 497 (10.3%) patients were excluded for protocol violation. Three hundred and forty-two of 446 (76.7%) patients presented for scheduled angiographic follow-up after 4.7 +/- 1.2 months and 29 of 446 (6.5%) prematurely. In-hospital complications comprised two deaths (0.8%) (P > 0.99) and one (0.4%) (P > 0.99) CK-elevation in each group, target lesion revascularization in 5 of 250 (2%) of the Tenax and 4 of 244 (1.6%) of the Nir sample (P > 0.99), and subacute thrombosis in 2 of 250 (0.8%) of the Tenax patients (P = 0.5). In the Tenax/Nir patients mean percent diameter stenosis decreased from 82.3 +/- 9.1%/80.7 +/- 8.4% (P = 0.49) to 17.6 +/- 5.5%/17.6 +/- 5.5% (P = 0.99) postprocedure and increased to 34.5 +/- 21.5%/34.2 +/- 23.1% (P = 0.90) at follow-up. CONCLUSIONS: Thus, there appears to be no advantage of the silicon carbide coated stent over a stainless steel stent after 4.7 +/- 1.2 months with regard to clinical and angiographic restenosis rates.


Assuntos
Compostos Inorgânicos de Carbono , Compostos de Silício , Stents , Doença das Coronárias/terapia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA