Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Biomedicines ; 12(1)2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38255208

RESUMO

BACKGROUND: Multiple system atrophy (MSA) is a neurodegenerative disease. It has a fast progression, so early diagnosis is decisive. Two functional imaging tests can be involved in its diagnosis: [123I]Ioflupane SPECT and [123I]MIBG scintigraphy. Our aim is to comparatively analyze the diagnostic performance of both techniques. METHODS: 46 patients (24 males and 22 females) with MSA underwent [123I]Ioflupane SPECT and [123I]MIBG scintigraphy. In each of these techniques, qualitative assessment was compared with quantitative assessment. RESULTS: SPECT visual assessment was positive in 93.5% of subjects (S = 95.24%; PPV = 93.02%). A cut-off of 1.363 was established for overall S/O index (S = 85.7%, E = 100%). Visual assessment of scintigraphy was positive in 73.1% (S = 78.57%, PPV = 94.29%). For the delayed heart/medistinum ratio (HMR) a cut-off of 1.43 (S = 85.3, E = 100%) was obtained. For each unit increase in delayed HMR, the suspicion of MSA increased by 1.58 (OR = 1.58, p < 0.05). The quantitative assessment showed an association with the visual assessment for each technique (p < 0.05). CONCLUSIONS: Both tests are useful in MSA diagnosis. Comparatively, we did not observe a clear superiority of either. Striatal and myocardial deterioration do not evolve in parallel. Qualitative assessment is crucial in both techniques, together with the support of quantitative analysis. Delayed HMR shows a direct relationship with the risk of MSA.

2.
Clin Nucl Med ; 49(2): e65-e67, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38048549

RESUMO

ABSTRACT: [ 99m Tc]Tc-DPD (3,3-diphosphono-1,2-propanodicarboxylic acid) scintigraphy is an essential tool for diagnosing transthyretin amyloid cardiac amyloidosis. An 86-year-old woman suffering from heart failure with preserved ejection fraction underwent [ 99m Tc]Tc-DPD scintigraphy and a SPECT/CT for suspected transthyretin amyloid cardiac amyloidosis. The scan showed intracardiac and liver uptake. As the patient had taken intravenous iron on the morning of the scan, we decided to repeat the scan, but this time, it showed no uptake in the heart or the liver. Accordingly, we concluded the first result was a false positive due to drug interaction.


Assuntos
Amiloidose , Cardiomiopatias , Feminino , Humanos , Idoso de 80 Anos ou mais , Pré-Albumina , Compostos de Organotecnécio , Amiloidose/diagnóstico por imagem , Coração , Cintilografia , Amiloide , Cardiomiopatias/diagnóstico por imagem
3.
Biomedicines ; 11(11)2023 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-38001894

RESUMO

BACKGROUND: Multiple system atrophy (MSA) is subdivided into two types: MSA-P (parkinsonian) and MSA-C (cerebellar). Brain SPECT allows for the detection of nigrostriatal involvement, even in the early stages. To date, the scientific literature does not show a consensus on how to follow-up MSA, especially MSA-C. Our aim was to analyze the diagnostic effectiveness of repeat [123I]Ioflupane SPECT for the follow-up of MSA. METHODS: A longitudinal observational study on 22 MSA patients (11 males and 11 females). RESULTS: Significant changes were obtained in the quantitative SPECT assessments in the three Striatum/Occipital indices. The qualitative SPECT diagnosis did not show differences between the initial and evolving SPECT, but the neurologist's clinical suspicion did. Our results showed a brain deterioration of around 31% at 12 months, this being the optimal cut-off for differentiating a diseased subject (capable of solving diagnostic error rate). Previous imaging tests were inconclusive, as they showed less deterioration in the SPECT and quantitative assessments with respect to the group of confirmed patients. Repeated SPECT increased the diagnostic sensitivity (50% vs. 75%) and positive predictive value (72.73% vs. 77%). In addition, repeated SPECT proved decisive in the diagnosis of initial inconclusive cases. CONCLUSION: Repeat SPECT at 12 months proves useful in the diagnosis and follow-up of MSA.

4.
J Clin Med ; 12(10)2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-37240584

RESUMO

BACKGROUND: Multiple system atrophy (MSA) is a rapidly progressive neurodegenerative disorder that has no curative treatment. Diagnosis is based on a set of criteria established by Gilman (1998 and 2008) and recently updated by Wenning (2022). We aim to determine the effectiveness of [123I]Ioflupane SPECT in MSA, especially at the initial clinical suspicion. METHODS: A cross-sectional study of patients at the initial clinical suspicion of MSA, referred for [123I]Ioflupane SPECT. RESULTS: Overall, 139 patients (68 men, 71 women) were included, 104 being MSA-probable and 35 MSA-possible. MRI was normal in 89.2%, while SPECT was positive in 78.45%. SPECT showed high sensitivity (82.46%) and positive predictive value (86.24), reaching maximum sensitivity in MSA-P (97.26%). Significant differences were found when relating both SPECT assessments in the healthy-sick and inconclusive-sick groups. We also found an association when relating SPECT to the subtype (MSA-C or MSA-P), as well as to the presence of parkinsonian symptoms. Lateralization of striatal involvement was detected (left side). CONCLUSIONS: [123I]Ioflupane SPECT is a useful and reliable tool for diagnosing MSA, with good effectiveness and accuracy. Qualitative assessment shows a clear superiority when distinguishing between the healthy-sick categories, as well as between the parkinsonian (MSA-P) and cerebellar (MSA-C) subtypes at initial clinical suspicion.

6.
Clin Nucl Med ; 38(2): e103-5, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23334140

RESUMO

Hemiplegic migraine (HM) is an unusual type of migraine, with few cases reported in the literature. Unlike other types of migraine, aura HM presents accompanying motor deficit manifestations that do not last more than 24 hours. We report a 27-year-old man referred to us from the emergency department to carry out a cerebral perfusion SPECT with (99m)Tc-HMPAO. He presented with intense headache and motor weakness. The brain perfusion scan was performed before and after intravenous infusion with nimodipine and showed a significant change of cerebral blood flow, allowing early and correct diagnosis.


Assuntos
Encéfalo/diagnóstico por imagem , Enxaqueca com Aura/diagnóstico por imagem , Imagem de Perfusão , Tecnécio Tc 99m Exametazima , Adulto , Encéfalo/irrigação sanguínea , Humanos , Masculino , Enxaqueca com Aura/patologia , Enxaqueca com Aura/fisiopatologia , Tomografia Computadorizada de Emissão de Fóton Único
7.
Med Clin (Barc) ; 137(10): 440-3, 2011 Oct 15.
Artigo em Espanhol | MEDLINE | ID: mdl-21396668

RESUMO

BACKGROUND AND OBJECTIVE: To assess the functional state of nigro-striatal pathway using FP-CIT-I-123 in patients with clinical diagnosis of Multiple System Atrophy (MSA) subtype C. PATIENTS AND METHODS: We included 10 patients with a clinical diagnosis of MSA-C and compared them with 10 patients diagnosed with essential tremor (controls) and 10 with Parkinson Disease (PD). The studies are evaluated by the striatum/occipital index (S/O). We calculated the diagnostic validity of the procedure by ROC curve analysis. RESULTS: The average value of the S/O index showed a mean of 1.48 (0.23), 1.59 (0.17) and 1.22 (0.16) respectively for MSA-C, control group (p=0.25) and PD (p=0.00). ROC curve analysis: Az: 0.650; sensitivity: 0.50; specificity: 0.80. The comparison between the results of FP-CIT and clinical manifestations showed: 4 patients with parkinsonism (PK) and pathological study; 4 without PK and normal study; 1 with PK and normal study and 1 without PK and pathological study. CONCLUSIONS: FP-CIT study does not exclude completely the existence of an MSA-C. From a functional point of view, there does not always seem to be a consistency between the state of the nigro-striatal pathway and the existence of parkinsonism.


Assuntos
Radioisótopos de Carbono , Corpo Estriado/diagnóstico por imagem , Proteínas da Membrana Plasmática de Transporte de Dopamina/análise , Radioisótopos de Flúor , Radioisótopos do Iodo , Atrofia de Múltiplos Sistemas/diagnóstico por imagem , Transtornos Parkinsonianos/diagnóstico por imagem , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único , Tropanos , Idoso , Idoso de 80 Anos ou mais , Radioisótopos de Carbono/farmacocinética , Cerebelo/fisiopatologia , Corpo Estriado/química , Tremor Essencial/diagnóstico por imagem , Feminino , Radioisótopos de Flúor/farmacocinética , Humanos , Radioisótopos do Iodo/farmacocinética , Masculino , Pessoa de Meia-Idade , Atrofia de Múltiplos Sistemas/classificação , Atrofia de Múltiplos Sistemas/complicações , Atrofia de Múltiplos Sistemas/metabolismo , Proteínas do Tecido Nervoso/análise , Doença de Parkinson/diagnóstico por imagem , Transtornos Parkinsonianos/etiologia , Curva ROC , Compostos Radiofarmacêuticos/farmacocinética , Tropanos/farmacocinética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA