Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Anal Chem ; 95(40): 15078-15085, 2023 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-37715701

RESUMO

Quantitative analysis of binary mixtures of tris(2-phenylpyridinato)iridium(III) (Ir(ppy)3) and tris(8-hydroxyquinolinato)aluminum (Alq3) by using an artificial neural network (ANN) system to mass spectra was attempted based on the results of a VAMAS (Versailles Project on Advanced Materials and Standards) interlaboratory study (TW2 A31) to evaluate matrix-effect correction and to investigate interface determination. Monolayers of binary mixtures having different Ir(ppy)3 ratios (0, 0.25, 0.50, 0.75, and 1.00), and the multilayers containing these mixtures and pure samples were measured using time-of-flight secondary ion mass spectrometry (ToF-SIMS) with different primary ion beams, OrbiSIMS (SIMS with both Orbitrap and ToF mass spectrometers), laser desorption ionization (LDI), desorption/ionization induced by neutral clusters (DINeC), and X-ray photoelectron spectroscopy (XPS). The mass spectra were analyzed using a simple ANN with one hidden layer. The Ir(ppy)3 ratios of the unknown samples and the interfaces of the multilayers were predicted using the simple ANN system, even though the mass spectra of binary mixtures exhibited matrix effects. The Ir(ppy)3 ratios at the interfaces indicated by the simple ANN were consistent with the XPS results and the ToF-SIMS depth profiles. The simple ANN system not only provided quantitative information on unknown samples, but also indicated important mass peaks related to each molecule in the samples without a priori information. The important mass peaks indicated by the simple ANN depended on the ionization process. The simple ANN results of the spectra sets obtained by a softer ionization method, such as LDI and DINeC, suggested large ions such as trimers. From the first step of the investigation to build an ANN model for evaluating mixture samples influenced by matrix effects, it was indicated that the simple ANN method is useful for obtaining candidate mass peaks for identification and for assuming mixture conditions that are helpful for further analysis.

2.
Rapid Commun Mass Spectrom ; 37(4): e9445, 2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-36457202

RESUMO

RATIONALE: Matrix effects cause a nonlinear relationship between ion intensities and concentrations in mass spectrometry, including time-of-flight secondary ion mass spectrometry (ToF-SIMS). Here, two artificial neural network (ANN)-based methods, autoencoder-based and simple ANN methods, were employed for the quantitative and qualitative analyses of a two organic compound mixture via ToF-SIMS. METHODS: The multilayer model sample contained a mixture of Irganox 1010 and Fmoc-pentafluoro-L-phenylalanine (Fmoc-PFLPA). The sample's positive and negative ion depth profiles were collected through ToF-SIMS. ToF-SIMS-derived cross-sectional image datasets were analyzed using three unsupervised methods, namely principal component analysis (PCA), multivariate curve resolution (MCR), and use of a sparse autoencoder (SAE). The supervised simple ANN method was optimized based on the spectra and validated by predicting the test dataset ratios of Irganox 1010. RESULTS: The results obtained using the SAE demonstrated linear calibration curves and appropriate material distribution images. The Irganox 1010 and Fmoc-PFLPA positive and negative ion datasets exhibited >0.97 correlation coefficients. The PCA and MCR results demonstrated lower linearity than that of SAE. Moreover, SAE weights indicated the ions important for each organic compound. The simple ANN method accurately predicted the ratios in the test dataset and indicated the important ions. CONCLUSIONS: Both the supervised and unsupervised methods based on ANN, which were employed in regulating nonlinear relationships, were effective in the quantitative and qualitative analyses of the ToF-SIMS data of the two organic compound mixtures. Regarding qualitative analysis, both ANN-based methods indicated specific ions from the molecules in the sample.


Assuntos
Compostos Orgânicos , Espectrometria de Massa de Íon Secundário , Espectrometria de Massa de Íon Secundário/métodos , Redes Neurais de Computação , Hidroxitolueno Butilado
3.
Anal Bioanal Chem ; 414(2): 1177-1186, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34729645

RESUMO

Time-of-flight secondary ion mass spectrometry (TOF-SIMS) is a useful and versatile tool for surface analysis, enabling detailed compositional information to be obtained for the surfaces of diverse samples. Furthermore, in the case of two- or three-dimensional imaging, the measurement sensitivity in the higher molecular weight range can be improved by using a cluster ion source, thus further enriching the TOF-SIMS information. Therefore, appropriate analytical methods are required to interpret this TOF-SIMS data. This study explored the capabilities of a sparse autoencoder, a feature extraction method based on artificial neural networks, to process TOF-SIMS image data. The sparse autoencoder was applied to TOF-SIMS images of human skin keratinocytes to extract the distribution of endogenous intercellular lipids and externally penetrated drugs. The results were compared with those obtained using principal component analysis (PCA) and multivariate curve resolution (MCR), which are conventionally used for extracting features from TOF-SIMS data. This confirmed that the sparse autoencoder matches, and often betters, the feature extraction performance of conventional methods, while also offering greater flexibility.


Assuntos
Espectrometria de Massas/métodos , Pele/diagnóstico por imagem , Humanos , Espectrometria de Massa de Íon Secundário/métodos
4.
Anal Chem ; 93(9): 4191-4197, 2021 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-33635050

RESUMO

We report the results of a VAMAS (Versailles Project on Advanced Materials and Standards) interlaboratory study on the identification of peptide sample TOF-SIMS spectra by machine learning. More than 1000 time-of-flight secondary ion mass spectrometry (TOF-SIMS) spectra of six peptide model samples (one of them was a test sample) were collected using 27 TOF-SIMS instruments from 25 institutes of six countries, the U. S., the U. K., Germany, China, South Korea, and Japan. Because peptides have systematic and simple chemical structures, they were selected as model samples. The intensity of peaks in every TOF-SIMS spectrum was extracted using the same peak list and normalized to the total ion count. The spectra of the test peptide sample were predicted by Random Forest with 20 amino acid labels. The accuracy of the prediction for the test spectra was 0.88. Although the prediction of an unknown peptide was not perfect, it was shown that all of the amino acids in an unknown peptide can be determined by Random Forest prediction and the TOF-SIMS spectra. Moreover, the prediction of peptides, which are included in the training spectra, was almost perfect. Random Forest also suggests specific fragment ions from an amino acid residue Q, whose fragment ions detected by TOF-SIMS have not been reported, in the important features. This study indicated that the analysis using Random Forest, which enables translation of the mathematical relationships to chemical relationships, and the multi labels representing monomer chemical structures, is useful to predict the TOF-SIMS spectra of an unknown peptide.

5.
Anal Chem ; 91(22): 14545-14551, 2019 11 19.
Artigo em Inglês | MEDLINE | ID: mdl-31621296

RESUMO

The protist (mostly single-celled organisms), Paramecium bursaria, forms an intracellular symbiotic relationship with the single-celled algae, Chlorella variabilis, where P. bursaria provides nutrients (i.e., Ca2+, Mg2+, and K+), carbon dioxide for photosynthesis and protection from viruses, while C. variabilis provides oxygen, carbon fixation, and nutrients. Key to this successful relationship is the perialgal vacuole (PV) membrane, which surrounds C. variabilis and protects it from digestion by P. bursaria. The membrane is fragile and difficult to analyze using conventional methods therefore very little is known about the molecular composition. We used the OrbiSIMS, a new high-resolution mass spectrometer with subcellular resolution imaging, to study the compartmentalization of endosymbionts and elucidate biomolecular interactions between the host and endosymbiont. Ions from the region of interest, close to C. variabilis, and specific to the target samples containing PVs were found based on the chemical mapping and masses of the ions. We show chemical localizations of oligosaccharides in close proximity of C. variabilis endosymbionts in P. bursaria. These oligosaccharides are detected in host-endosymbiont samples containing PV membrane-bound algae and absent in free-living algae and digestive vacuole (DV) membrane-bound algae in P. bursaria.


Assuntos
Chlorella/química , Membranas Intracelulares/química , Paramecium/química , Vacúolos/química , Espectrometria de Massas , Oligossacarídeos/análise , Simbiose/fisiologia
6.
Anal Bioanal Chem ; 409(27): 6387-6396, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28842768

RESUMO

Blood adsorption onto the inside surface of hollow fiber dialysis membranes was investigated by means of time-of-flight secondary ion mass spectrometry (TOF-SIMS) and near-field infrared microscopy (NFIR) in order to evaluate the biocompatibility and permeability of dialysis membranes. TOF-SIMS is useful for the imaging of particular molecules with a high spatial resolution of approximately 100 nm. In contrast, infrared spectra provide quantitative information and NFIR enables analysis with a high spatial resolution of less than 1 µm, which is close to the resolution of TOF-SIMS. A comparison was made of one of the most widely used dialysis membranes made of polysulfone (PSf), that has an asymmetric and inhomogeneous pore structure, and a newly developed asymmetric cellulose triacetate (ATA) membrane that also has an asymmetric pore structure, even though the conventional cellulose triacetate membrane has a symmetric and homogeneous pore structure. As a result, it was demonstrated that blood adsorption on the inside surface of the ATA membrane is more reduced than that on the PSf membrane. Graphical abstract Analysis of blood adsorption on inside surface of hollow fiber membrane.


Assuntos
Materiais Biocompatíveis/química , Análise Química do Sangue , Celulose/análogos & derivados , Membranas Artificiais , Polímeros/química , Diálise Renal/instrumentação , Sulfonas/química , Adsorção , Sangue , Celulose/química , Humanos , Raios Infravermelhos , Teste de Materiais/métodos , Microscopia/métodos , Permeabilidade , Porosidade , Espectrometria de Massa de Íon Secundário/métodos
7.
Anal Chem ; 88(7): 3592-7, 2016 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-26916620

RESUMO

Peptide or protein structural analysis is crucial for the evaluation of biochips and biodevices, therefore an analytical technique with the ability to detect and identify protein and peptide species directly from surfaces with high lateral resolution is required. In this report, the efficacy of ToF-SIMS to analyze and identify proteins directly from surfaces is evaluated. Although the physics governing the SIMS bombardment process precludes the ability for researchers to detect intact protein or larger peptides of greater than a few thousand mass unit directly, it is possible to obtain information on the partial structures of peptides or proteins using low energy per atom argon cluster ion beams. Large cluster ion beams, such as Ar clusters and C60 ion beams, produce spectra similar to those generated by tandem MS. The SIMS bombardment process also produces peptide fragment ions not detected by conventional MS/MS techniques. In order to clarify appropriate measurement conditions for peptide structural analysis, peptide fragmentation dependency on the energy of a primary ion beam and ToF-SIMS specific fragment ions are evaluated. It was found that the energy range approximately 6 ≤ E/n ≤ 10 eV/atom is most effective for peptide analysis based on peptide fragments and [M + H] ions. We also observed the cleaving of side chain moieties at extremely low-energy E/n ≤ 4 eV/atom.


Assuntos
Argônio/química , Fulerenos/química , Fragmentos de Peptídeos/análise , Fragmentos de Peptídeos/química , Espectrometria de Massa de Íon Secundário , Íons/química , Conformação Proteica , Propriedades de Superfície , Espectrometria de Massas em Tandem
8.
Rapid Commun Mass Spectrom ; 29(18): 1687-95, 2015 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-26467120

RESUMO

RATIONALE: Time-of-flight secondary ion mass spectrometry (TOF-SIMS) with an Ar cluster ion beam as a primary ion source provides useful information in terms of peptide analysis. It is, however, difficult to interpret the spectra. The ToF-SIMS peptide spectra obtained with Ar clusters having different energies have been investigated in order to classify the secondary ions into the peptide fragment ions and those related to contaminants or the substrate. METHODS: Three peptides having different molecular weights from 600 to 1300 u were measured with Ar cluster beams having different energies per atom from 4 to 40 eV/atom. RESULTS: In the spectra normalized to a geometric average of all the spectra, the amino acid fragment ions are distinguished from other secondary ions. In the mass range above 600 u, the peptide fragment ions increase with mass while those not related to the peptide decrease with mass. CONCLUSIONS: Energy-dependence fragmentation helps in understanding the peptide spectra. Specific peptide fragment ions of the larger peptides are likely to be detected under lower energy than energy higher than 10 eV/atom. Although it is difficult to interpret the TOF-SIMS spectra of a peptide obtained with an Ar cluster ion beam, the secondary ions can be classified by comparing those obtained with different energy Ar cluster ion beams.


Assuntos
Argônio/química , Fragmentos de Peptídeos/química , Espectrometria de Massa de Íon Secundário/métodos , Íons/química , Fragmentos de Peptídeos/análise , Espectrometria de Massas em Tandem/métodos
9.
Anal Bioanal Chem ; 407(10): 2859-63, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25687682

RESUMO

The adsorption behaviour of amyloid beta (Aß), thought to be a key peptide for understanding Alzheimer's disease, was investigated by means of time-of-flight secondary ion mass spectrometry (ToF-SIMS). Aß aggregates depending on the lipid membrane condition though it has not been fully understood yet. In this study, Aß samples on different lipid membranes, 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC), 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC) and 1,2-dioleoyl-sn-glycero-3-phosphocholine (DOPC), were observed with ToF-SIMS and the complex ToF-SIMS data of the Aß samples was interpreted using data analysis techniques such as principal component analysis (PCA), gentle-SIMS (G-SIMS) and g-ogram. DOPC and DMPC are liquid crystal at room temperature, while DPPC is gel at room temperature. As primary ion beams, Bi3(+) and Ar cluster ion beams were used and the effect of an Ar cluster ion for evaluating biomolecules was also studied. The secondary ion images of the peptide fragment ions indicated by G-SIMS and g-ogram were consistent with the PCA results. It is suggested that Aß is adsorbed homogeneously on the liquid-crystalline-phase lipid membranes, while it aggregates along the lipid on the gel-phase lipid membrane. Moreover, in the results using the Ar cluster, the influence of contamination was reduced.


Assuntos
Peptídeos beta-Amiloides/metabolismo , Lipídeos de Membrana/química , Espectrometria de Massa de Íon Secundário/métodos , 1,2-Dipalmitoilfosfatidilcolina/análogos & derivados , 1,2-Dipalmitoilfosfatidilcolina/química , Sequência de Aminoácidos , Peptídeos beta-Amiloides/química , Dimiristoilfosfatidilcolina/química , Glicerilfosforilcolina/análogos & derivados , Glicerilfosforilcolina/química , Processamento de Imagem Assistida por Computador , Lipídeos de Membrana/metabolismo , Dados de Sequência Molecular , Fosfatidilcolinas , Análise de Componente Principal
10.
Anal Bioanal Chem ; 405(21): 6621-8, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23836082

RESUMO

A novel application of time-of-flight secondary ion mass spectrometry (ToF-SIMS) with continuous Ar cluster beams to peptide analysis was investigated. In order to evaluate peptide structures, it is necessary to detect fragment ions related to multiple neighbouring amino acid residues. It is, however, difficult to detect these using conventional ToF-SIMS primary ion beams such as Bi cluster beams. Recently, C60 and Ar cluster ion beams have been introduced to ToF-SIMS as primary ion beams and are expected to generate larger secondary ions than conventional ones. In this study, two sets of model peptides have been studied: (des-Tyr)-Leu-enkephalin and (des-Tyr)-Met-enkephalin (molecular weights are approximately 400 Da), and [Asn(1) Val(5)]-angiotensin II and [Val(5)]-angiotensin I (molecular weights are approximately 1,000 Da) in order to evaluate the usefulness of the large cluster ion beams for peptide structural analysis. As a result, by using the Ar cluster beams, peptide molecular ions and large fragment ions, which are not easily detected using conventional ToF-SIMS primary ion beams such as Bi3 (+), are clearly detected. Since the large fragment ions indicating amino acid sequences of the peptides are detected by the large cluster beams, it is suggested that the Ar cluster and C60 ion beams are useful for peptide structural analysis.


Assuntos
Aminoácidos/análise , Aminoácidos/química , Argônio/química , Fulerenos/química , Peptídeos/análise , Peptídeos/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Sequência de Aminoácidos , Aminoácidos/efeitos da radiação , Íons Pesados , Dados de Sequência Molecular , Peptídeos/efeitos da radiação
11.
Rapid Commun Mass Spectrom ; 26(23): 2815-21, 2012 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-23124673

RESUMO

RATIONALE: Secondary ion mass spectrometry (SIMS) is an important technique for the characterization of proteins at surfaces. However, interpretation of the mass spectra is complicated owing to confusion with peaks from contaminants and the substrate which is further compounded by complex fragmentation mechanisms. We test a new development of the G-SIMS method called the g-ogram to separate out spectral components without a priori information about which peaks to include in the analysis and which peaks relate to each component. METHODS: The effectiveness of the g-ogram method is investigated using a model system of lysozyme adsorbed onto a silicon wafer and indium tin oxide substrates. In the method, two SIMS spectra are acquired using Bi(+) and Mn(+) primary ions which create lower and higher fragmentation in the spectra, respectively. The g-ogram separates out components using a separation parameter that is related to the fragmentation energy. RESULTS: The g-ogram separates the spectrum of lysozyme adsorbed onto a silicon wafer into three components: (i) the substrate and PDMS contamination; (ii) a second, but unexpected, contaminant; and (iii) peaks from the protein amino acids. Similar results are achieved for the indium tin oxide substrate. In addition, evidence of fragments from plural amino acids with two candidate peaks at 140.12 Da and 185.08 Da is observed. CONCLUSIONS: The g-ogram method effectively separates out mass peaks relating to the substrate, contamination and protein without any a priori information or subjective decisions about which peaks to include in the analysis (so called 'peak picking'). This is a great help to analysts. We find two possible peaks from plural amino acids but no evidence of pluralities is found for peaks above 240 Da that are generated from when using Bi or Mn primary ions.


Assuntos
Muramidase/química , Espectrometria de Massa de Íon Secundário/métodos , Sequência de Aminoácidos , Animais , Galinhas , Vidro/química , Dados de Sequência Molecular , Silício/química , Compostos de Estanho/química
12.
Sci Rep ; 11(1): 8553, 2021 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-33879813

RESUMO

The dynamics of hydrogen in metals with mixed grain structure is not well understood at a microscopic scale. One of the biggest issues facing the hydrogen economy is "hydrogen embrittlement" of metal induced by hydrogen entering and diffusing into the material. Hydrogen diffusion in metallic materials is difficult to grasp owing to the non-uniform compositions and structures of metal. Here a time-resolved "operando hydrogen microscope" was used to interpret local diffusion behaviour of hydrogen in the microstructure of a stainless steel with austenite and martensite structures. The martensite/austenite ratios differed in each local region of the sample. The path of hydrogen permeation was inferred from the time evolution of hydrogen permeation in several regions. We proposed a model of hydrogen diffusion in a dual-structure material and verified the validity of the model by simulations that took into account the transfer of hydrogen at the interfaces.

13.
Org Biomol Chem ; 8(14): 3338-42, 2010 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-20526486

RESUMO

A mild, efficient and LiCl-free synthetic method for indole derivatives based on the heteroannulation of alkynes with 2-iodoanilines was achieved using palladium on carbon (Pd/C) and NaOAc in heated NMP. The N-tosyl protection of 2-iodoaniline expedited the reaction progress, while other protecting groups, such as tert-butoxycarbonyl, acetyl, and benzyloxycarbonyl groups, underwent deprotection under the present conditions. A variety of di- and monosubstituted alkynes could effectively react with N-tosyl-2-iodoaniline to give the corresponding indoles in good to high yields.


Assuntos
Carbono/química , Indóis/química , Indóis/síntese química , Paládio/química , Alcinos/química , Compostos de Anilina/química , Catálise , Cloreto de Lítio/química
14.
Biointerphases ; 15(2): 021013, 2020 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-32312054

RESUMO

Time-of-flight secondary ion mass spectrometry (TOF-SIMS) is extensively employed for the structural analysis of the outermost surfaces of organic materials, including biological materials, because it provides detailed compositional information and enables high-spatial-resolution chemical mapping. In this study, a combination of TOF-SIMS and data analysis was employed to evaluate biological materials composed of numerous proteins, including unknown ones. To interpret complicated TOF-SIMS data of human hair, an autoencoder, a dimensionality reduction method based on artificial neural networks, was applied. Autoencoders can be used to perform nonlinear analysis; therefore, they are more suitable than principal component analysis (PCA) for analyzing TOF-SIMS data, which are influenced by the matrix effect. As a model sample data, the TOF-SIMS depth profile of human hair, acquired via argon gas cluster ion beam sputtering and Bi3 2+ primary ion beam, was employed. Useful information, including the characteristic distributions of amino acids and permeated surfactants on the outermost surface of the hair, was extracted from the results obtained from the autoencoder. Furthermore, the autoencoder extracted more detailed features than did PCA. Therefore, autoencoders can become a powerful tool for TOF-SIMS data analysis.


Assuntos
Cabelo/química , Redes Neurais de Computação , Espectrometria de Massa de Íon Secundário , Adulto , Algoritmos , Humanos , Masculino , Análise de Componente Principal
15.
Biointerphases ; 15(3): 031013, 2020 06 23.
Artigo em Inglês | MEDLINE | ID: mdl-32575993

RESUMO

In this study, the authors evaluated the distribution of low-abundance beauty ingredients in human skin tissues. The distribution of collagen tripeptide, a beauty ingredient, in the human skin was evaluated by applying multivariate curve resolution (MCR) to the time-of-flight secondary ion mass spectrometry mapping data, including reference information. The intensity of the secondary ion peaks was increased by the accumulation of secondary ion intensity in the depth direction obtained by argon cluster sputtering. Consequently, the collagen tripeptide distribution in the skin was evaluated by separating it from collagen peptide, although the conventional analysis was difficult because of the dilution of the collagen tripeptide in the skin. Additionally, the distribution of the collagen tripeptide in the skin may be determined with an autoencoder. In this study, the distribution of small amounts of beauty ingredients (the collagen tripeptide) in the skin was observed by integrating the secondary ion intensity in the depth direction with Ar cluster sputtering and applying MCR or autoencoder.


Assuntos
Cosméticos/análise , Pele/metabolismo , Espectrometria de Massa de Íon Secundário , Colágeno/química , Humanos , Análise Multivariada , Oligopeptídeos/química
16.
Biointerphases ; 15(2): 021010, 2020 04 09.
Artigo em Inglês | MEDLINE | ID: mdl-32272844

RESUMO

With regard to life sciences, it is important to understand biological functions such as metabolic reactions at the cellular level. Time-of-flight secondary ion mass spectrometry (TOF-SIMS) that can provide chemical mappings at 100 nm lateral resolutions is useful for obtaining three-dimensional maps of biological molecules in cells and tissues. TOF-SIMS spectra generally contain several hundred to several thousand secondary ion peaks that provide detailed chemical information. In order to manage such a large number of peaks, data analysis methods such as multivariate analysis techniques have been applied to TOF-SIMS data of complex samples. However, the interpretation of the data analysis results is sometimes still difficult, especially for biological samples. In this study, TOF-SIMS data of resin-embedded plant samples were analyzed using one of the sparse modeling methods, least absolute shrinkage and selection operator (LASSO), to directly select secondary ions related to biological structures such as cell walls and nuclei. The same sample was measured by optical microscopy and the same measurement area as TOF-SIMS was extracted in order to prepare a target image for LASSO. The same area of the TOF-SIMS and microscope data were fused to evaluate the influence of the image fusion on the TOF-SIMS spectrum information using principal component analysis. Specifically, the authors examined onion mycorrhizal root colonized with Gigaspora margarita (an arbuscular mycorrhizal fungus). The results showed that by employing this approach using LASSO, important secondary ions from biological samples were effectively selected and could be clearly distinguished from the embedding resin.


Assuntos
Algoritmos , Fungos/química , Espectrometria de Massa de Íon Secundário , Processamento de Imagem Assistida por Computador , Íons , Análise de Componente Principal
17.
Biointerphases ; 15(2): 021008, 2020 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-32241114

RESUMO

Matrix effects, which cause a change in ion intensity, occur in mass spectrometry methods including time-of-flight secondary ion mass spectrometry (TOF-SIMS). Matrix effects often cause large issues in quantitative analysis because secondary ions related to a particular molecule could be dramatically enhanced or suppressed regardless of the concentration. To investigate matrix effects in biological samples, the authors evaluated mixed lipid {POPC [1-palmitoyl-2-oleoyl-sn-glycero-3-phosphatidylcholine, molecular weight (MW) 759.6]}, peptide [leu-enkephalin, neo-leu-enkephalin (amino acid sequence: YAGFL, MW 569.3), and neo-angiotensin II (amino acid sequence: DRVYIHAF, MW 1019.5)] samples. Matrix effect features were investigated by analyzing the concentration dependence of secondary ions in lipid-peptide mixed samples to develop a method that enables quantitative analysis using TOF-SIMS. Matrix effects depended on the lipid-peptide combination. Interestingly, some secondary ions possessed an intensity that was highly dependent on concentration.


Assuntos
Lipídeos/análise , Peptídeos/análise , Espectrometria de Massa de Íon Secundário , Angiotensina II/análise , Encefalina Leucina/análise , Fosfatidilcolinas/química
18.
Anal Biochem ; 385(1): 132-7, 2009 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-19017523

RESUMO

We previously reported a silica-binding protein, designated Si-tag, which can be used to immobilize proteins on silica surfaces. Here, we constructed a fusion protein of Si-tag and immunoglobulin-binding staphylococcal protein A for oriented immobilization of antibodies on a silicon wafer whose surface is oxidized to silicon dioxide (silica). The fusion protein, Si-tagged protein A, strongly bound to the silica surface with a dissociation constant of 0.31 nM. Time-of-flight secondary ion mass spectrometry analysis of the silicon wafer coated with Si-tagged protein A, combined with principal component analysis and mutual information, demonstrated that protein A is localized on the outermost surface of the bound protein layer. Immunoglobulin G (IgG) was immobilized both on the silicon wafer coated with Si-tagged protein A and, as a control, directly on the intact silicon wafer via physical adsorption. The silicon wafer coated with Si-tagged protein A bound 30-70% more IgG than the uncoated silicon wafer, whereas the antigen-binding activity was 4- to 5-fold higher for the former, indicating that IgG was functionally immobilized on the silicon wafer via Si-tagged protein A in an oriented manner.


Assuntos
Anticorpos Imobilizados/química , Imunoglobulina G/química , Dióxido de Silício/química , Proteína Estafilocócica A/química , Reações Antígeno-Anticorpo , Sítios de Ligação , Proteínas Recombinantes de Fusão/química , Espectrometria de Massa de Íon Secundário , Staphylococcus aureus/química , Propriedades de Superfície
19.
Sensors (Basel) ; 9(10): 8271-7, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-22408505

RESUMO

Fluorescence enhancement of fluorescein isothiocyanate-labeled protein A (FITC-protein A) caused by the binding with immunoglobulin G (IgG) in bovine plasma was studied. FITC-protein A was immobilized onto a glass surface by covalent bonds. An increase in fluorescence intensity was dependent on IgG concentration ranging from 20 to 78 µg/mL in both phosphate buffer saline and bovine plasma. This method requires no separation procedure, and the reaction time is less than 15 min. A fluorescence enhancement assay by the affinity binding of fluorescence-labeled reagent is thus available for the rapid determination of biomolecules in plasma.

20.
Carbohydr Res ; 482: 107739, 2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-31288124

RESUMO

Solvent-free synthesis encourages the design of processes and products that reduce the use and generation of hazardous chemicals. Given the importance of developing greener methodologies, we sought to determine the factors influencing the reaction temperature required for solvent-free, enzymatic synthesis of sugar esters such as trehalose (TRE) esters, using Novozyme 435 as the enzyme catalyst. The use of lauric acid (La) and ethyl laurate (LaEt) as acyl donors did not affect the activation temperature for the generation of trehalose diesters (TDEs), despite the differences in corresponding by-products (water and ethanol). However, when glucose (GLU) and La were employed as reaction substrates as a comparison, glucose monoester (GME) generation readily occurred at much lower temperatures than with the TRE esters, even without a water collection device. Moreover, when the glass transition temperature (Tg) of the sugar substrates increased, a higher reaction temperature was required. These results suggest that while the activation temperature of the reaction did not correlate with the boiling point of the by-product, it did correlate with the glass transition temperature (Tg) of the trehalose substrates. Thus, our work demonstrates the importance of the physical state of amorphous matrices in determining the optimal reaction temperature of a solvent-free sugar synthesis.


Assuntos
Ésteres/química , Temperatura , Trealose/química , Trealose/síntese química , Técnicas de Química Sintética , Glucose/química , Concentração de Íons de Hidrogênio , Lauratos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA