Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Int AIDS Soc ; 24(1): e25663, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33455081

RESUMO

INTRODUCTION: In many low- and middle-income countries, HIV viral load (VL) testing occurs at centralized laboratories and time-to-result-delivery is lengthy, preventing timely monitoring of HIV treatment adherence. Near point-of-care (POC) devices, which are placed within health facility laboratories rather than clinics themselves (i.e. "true" POC), can offer VL in conjunction with centralized laboratories to expedite clinical decision making and improve outcomes, especially for patients at high risk of treatment failure. We assessed impacts of near-POC VL testing on result receipt and clinical action in public sector programmes in Cameroon, Democratic Republic of Congo, Kenya, Malawi, Senegal, Tanzania and Zimbabwe. METHODS: Routine health data were collected retrospectively after introducing near-POC VL testing at 57 public sector health facilities (2017 to 2019, country-dependent). Where possible, key indicators were compared to data from patients receiving centralized laboratory testing using hazard ratios and the Somers' D test. RESULTS: Data were collected from 6795 tests conducted on near-POC and 17614 tests on centralized laboratory-based platforms. Thirty-one percent (2062/6694) of near-POC tests were conducted for high-risk populations: pregnant and breastfeeding women, children and those with suspected failure. Compared to conventional testing, near-POC improved the median time from sample collection to return of results to patient [six vs. sixty-eight days, effect size: -32.2%; 95% CI: -41.0% to -23.4%] and to clinical action for individuals with an elevated HIV VL [three vs. fourty-nine days, effect size: -35.4%; 95% CI: -46.0% to -24.8%]. Near-POC VL results were two times more likely to be returned to the patient within 90 days compared to centralized tests [50% (1781/3594) vs. 27% (4172/15271); aHR: 2.22, 95% CI: 2.05 to 2.39]. Thirty-seven percent (340/925) of patients with an elevated near-POC HIV VL result had documented clinical follow-up actions within 30 days compared to 7% (167/2276) for centralized testing. CONCLUSIONS: Near-POC VL testing enabled rapid test result delivery for high-risk populations and led to significant improvements in the timeliness of patient result receipt compared to centralized testing. While there was some improvement in time-to-clinical action with near-POC VL testing, major gaps remained. Strengthening of systems supporting the utilization of results for patient management are needed to truly capitalize on the benefits of decentralized testing.


Assuntos
Infecções por HIV/virologia , Sistemas Automatizados de Assistência Junto ao Leito , Carga Viral , Adolescente , Adulto , África Subsaariana , Idoso , Criança , Pré-Escolar , Feminino , Infecções por HIV/tratamento farmacológico , Instalações de Saúde , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Gravidez , Prática de Saúde Pública , Estudos Retrospectivos , Carga Viral/métodos , Adulto Jovem
2.
J Int AIDS Soc ; 24(3): e25677, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33745234

RESUMO

INTRODUCTION: Point-of-care (POC) early infant diagnosis (EID) testing has been shown to dramatically decrease turnaround times from sample collection to caregiver result receipt and time to ART initiation for HIV-positive infants compared to centralized laboratory testing. As governments in sub-Saharan Africa implement POC EID technologies, we report on the feasibility and effectiveness of POC EID testing and the impact of same-day result delivery on rapid ART initiation within national programmes across six countries. METHODS: This pre-/post-evaluation compared centralized laboratory-based (pre) with POC (post) EID testing in 52 facilities across Cameroon, Democratic Republic of Congo, Ethiopia, Kenya, Senegal and Zimbabwe between April 2017 and October 2019 (country-dependent). Data were collected retrospectively from routine records at health facilities for all infants tested under two years of age. Hazard ratios and 95% confidence intervals were calculated to compare time-to-event outcomes, visualized with Kaplan-Meier curves, and the Somers' D test was used to compare continuous outcomes. RESULTS: Data were collected for 2892 EID tests conducted on centralized laboratory-based platforms and 4610 EID tests on POC devices with 127 (4%) and 192 (4%) HIV-positive infants identified, respectively. POC EID significantly reduced the time from sample collection to caregiver result receipt (POC median: 0 days, IQR: 0 to 0 vs. centralized: 35 days, IQR: 26 to 56) and time from sample collection to ART initiation for HIV-positive infants (POC median: 1 day, IQR: 0 to 7 vs. centralized: 39 days, IQR: 26 to 57). With POC testing, 72% of infants received results on the same day as sample collection; HIV-positive infants with a same-day diagnosis had six times the rate of ART initiation compared to those diagnosed one or more days after sample collection (HR: 6.39; 95% CI: 3.44 to 11.85). CONCLUSIONS: Same-day diagnosis and treatment initiation for infants is possible with POC EID within routine government-led and -supported public sector healthcare facilities in resource-limited settings. Given that POC EID allows for rapid ART initiation, aligning to the World Health Organization's recommendation of ART initiation within seven days, its use in public sector programmes has the potential to reduce overall mortality for infants with HIV through early treatment initiation.


Assuntos
Continuidade da Assistência ao Paciente , Infecções por HIV/diagnóstico , Infecções por HIV/tratamento farmacológico , Testes Imediatos , Diagnóstico Precoce , Feminino , Programas Governamentais , Humanos , Lactente , Masculino , Avaliação de Programas e Projetos de Saúde , Estudos Retrospectivos
3.
PLoS One ; 15(1): e0226987, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31910221

RESUMO

BACKGROUND: Globally, nearly 22 million HIV-infected patients are currently accessing antiretroviral treatment; however, almost one million people living with HIV died of AIDS-related illnesses in 2018. Advanced HIV disease remains a significant issue to curb HIV-related mortality. METHODS: We analyzed 864,389 CD4 testing records collected by 1,016 Alere Pima Analyzers implemented at a variety of facilities, including peripheral facilities, between January 2012 and December 2016 across four countries in sub-Saharan Africa. Routinely collected data and programmatic records were used to analyze the median CD4 counts and proportions of patients with advanced HIV disease by country, facility type, and year. RESULTS: Median CD4 counts were between 409-444 cells/ul each year since 2012 with a median in 2016 of 444 cells/ul (n = 319,829). The proportion of test results returning CD4 counts above 500 cells/ul has increased slowly each year with 41.8% (95% CI: 41.6-41.9%) of tests having a CD4 count above 500 cells/ul in 2016. Median CD4 counts were similar across facility types. The proportion of test results indicating advanced HIV disease has remained fairly consistent: 19.4% (95% CI: 18.8-20.1%) in 2012 compared to 16.1% (95% CI: 16.0-16.3%) in 2016. The proportion of test results indicating advanced HIV disease annually ranged from 14.5% in Uganda to 29.8% in Cameroon. 6.9% (95% CI: 6.8-7.0%) of test results showed very advanced HIV disease (CD4<100 cells/ul) in 2016. CONCLUSIONS: The proportion of CD4 test results indicating advanced disease was relatively high and consistent across four high HIV burden countries.


Assuntos
Instituições de Assistência Ambulatorial , Infecções por HIV/diagnóstico , Atenção Primária à Saúde , África Subsaariana/epidemiologia , Contagem de Linfócito CD4 , Camarões , Coleta de Dados , Infecções por HIV/sangue , Infecções por HIV/epidemiologia , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Uganda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA