Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 34(8): 1698-1705, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37493499

RESUMO

INTRODUCTION: Among patients with non-valvular atrial fibrillation (AF) and percutaneous left atrial appendage closure (LAAC) undergoing direct current cardioversion (DCCV), the need for and use of LAA imaging and oral anticoagulation (OAC) is unclear. OBJECTIVE: The purpose of this study is to evaluate the real-world use of transesophageal echocardiography (TEE) or cardiac computed tomography angiography (CCTA) before DCCV and use of OAC pre- and post-DCCV in patients with AF status post percutaneous LAAC. METHODS: This retrospective single center study included all patients who underwent DCCV after percutaneous LAAC from 2016 to 2022. Key measures were completion of TEE or CCTA pre-DCCV, OAC use pre- and post-DCCV, incidence of left atrial thrombus (LAT) or device-related thrombus (DRT), incidence of peri-device leak (PDL), and DCCV-related complications (stroke, systemic embolism, device embolization, major bleeding, or death) within 30 days. RESULTS: A total of 76 patients with AF and LAAC underwent 122 cases of DCCV. LAAC consisted of 47 (62%), 28 (37%), and 1 (1%) case of Watchman 2.5, Watchman FLX, and Lariat, respectively. Among the 122 DCCV cases, 31 (25%) cases were identified as "non-guideline based" due to: (1) no OAC for 3 weeks and no LAA imaging within 48 h before DCCV in 12 (10%) cases, (2) no OAC for 4 weeks following DCCV in 16 (13%) cases, or (3) both in 3 (2%) cases. Among the 70 (57%) cases that underwent TEE or CCTA before DCCV, 16 (23%) cases had a PDL with a mean size of 3.0 ± 1.1 mm, and 4 (6%) cases had a LAT/DRT on TEE resulting in cancellation. There were no DCCV-related complications within 30 days. DISCUSSION: There is a widely varied practice pattern of TEE, CCTA, and OAC use with DCCV after LAAC, with a 6% rate of LAT/DRT. LAA imaging before DCCV appears prudent in all cases, especially within 1 year of LAAC, to assess for device position, PDL, and LAT/DRT.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cardiopatias , Acidente Vascular Cerebral , Trombose , Humanos , Estudos Retrospectivos , Cardioversão Elétrica/efeitos adversos , Apêndice Atrial/diagnóstico por imagem , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/prevenção & controle , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Ecocardiografia Transesofagiana , Resultado do Tratamento , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Cateterismo Cardíaco/efeitos adversos
2.
Pacing Clin Electrophysiol ; 46(7): 745-751, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37221927

RESUMO

BACKGROUND: Transesophageal echocardiography (TEE) and cardiac computed tomography angiography (CCTA) are currently utilized for left atrial appendage closure (LAAC) planning. During the recent global iodine contrast media shortage in 2022, cardiac magnetic resonance imaging (CMR) was utilized for the first time for LAAC planning. This study sought to assess the utility of CMR versus TEE for LAAC planning. METHODS: This single center retrospective study consisted of all patients who underwent preoperative CMR for LAAC with Watchman FLX or Amplatzer Amulet. Key measures were accuracy of LAA thrombus exclusion, ostial diameter, depth, lobe count, morphology, accuracy of predicted device size, and devices deployed per case. Bland-Altman Analysis was used to compare CMR versus TEE measurements of LAA ostial diameter and depth. RESULTS: 25 patients underwent preoperative CMR for LAAC planning. A total of 24 (96%) cases were successfully completed with 1.2 ± 0.5 devices deployed per case. Among the 18 patients who underwent intraoperative TEE, there was no significant difference between CMR versus TEE in LAA thrombus exclusion (CMR 83% vs. TEE 100% cases, p = .229), lobe count (CMR 1.7 ± 0.8 vs. TEE 1.4 ± 0.6, p = .177), morphology (p = .422), and accuracy of predicted device size (CMR 67% vs. TEE 72% cases, p = 1.000). When comparing the difference between CMR and TEE measurements, Bland-Altman analysis demonstrated no significant difference in LAA ostial diameter (CMR-TEE bias 0.7 mm, 95% CI [-1.1, 2.4], p = .420), but LAA depth was significantly larger with CMR versus TEE (CMR-TEE bias 7.4 mm, 95% CI [1.6, 13.2], p = .015). CONCLUSIONS: CMR is a promising alternative for LAAC planning in cases where TEE or CCTA are contraindicated or unavailable.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Trombose , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Ecocardiografia Transesofagiana/métodos , Imageamento por Ressonância Magnética , Trombose/diagnóstico por imagem , Cateterismo Cardíaco , Resultado do Tratamento
3.
J Cardiothorac Vasc Anesth ; 37(4): 627-631, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36732130

RESUMO

The remede System (ZOLL Medical, Minnetonka, MN; Fig 1), which was approved by the Food and Drug Administration in October of 2017, is a transvenous device that stimulates the phrenic nerve for the treatment of central sleep apnea, which is often associated with heart failure and atrial fibrillation. Given the similarity in implantation procedure to pacemakers and implantable cardioverter/defibrillators, the remede System implantation often occurs in the electrophysiology laboratory. Despite the transvenous nature and close proximity to cardiac structures on radiographic imaging, the remede System does not have any cardiac pacing function/antiarrhythmia therapies, and it is important for an anesthesiologist to be able to recognize and manage such a device if they were to come across one preoperatively.


Assuntos
Desfibriladores Implantáveis , Apneia do Sono Tipo Central , Procedimentos Cirúrgicos Torácicos , Humanos , Resultado do Tratamento , Nervo Frênico , Apneia do Sono Tipo Central/terapia
4.
J Cardiovasc Electrophysiol ; 33(9): 2111-2115, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35842796

RESUMO

INTRODUCTION: Leadless cardiac pacing has not been widely utilized in pediatric patients, in part due to concerns regarding size of the delivery sheath and the potential for vascular injury. METHODS: We present a case of leadless pacemaker implantation via internal jugular vein without a surgical cutdown. RESULTS: A leadless pacemaker was successfully implanted in the right ventricle via internal jugular approach in a pediatric patient with congenital heart disease. CONCLUSION: This is a novel approach to leadless pacemaker implantation that could broaden the utilization of this technology to the vulnerable population of children, especially those with congenital heart disease.


Assuntos
Marca-Passo Artificial , Criança , Ventrículos do Coração , Humanos , Próteses e Implantes
5.
J Cardiovasc Electrophysiol ; 32(11): 3027-3034, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34554620

RESUMO

INTRODUCTION: Defibrillation testing (DT) is recommended during the subcutaneous defibrillator (S-ICD) placement. We sought to compare 10 J shock impedance in sinus rhythm (SR) with 65 J defibrillation impedance and evaluate device position on a postimplant chest X-ray (CXR) using an intermuscular (IM) technique. METHODS: Consecutive S-ICD implantations between 12/2019 and 12/2020 at The Ohio State University were reviewed. All implantations were performed using a two-incision IM technique. Standard DT with 65 J shock and 10 J shock in SR were performed unless contraindicated. The PRAETORIAN score was calculated based on CXR. RESULTS: A total of 37 patients (age: 47.2 ± 15.8 years old, male: n = 26 [70.3%], body mass index: 30.1 ± 6.7 kg/m2 ) underwent IM S-ICD implantation, and of those, 27 (73%) underwent both 65 J shock and 10 J shock in SR. The coefficient of determination (R2 ) between 10 J shock impedance and 65 J shock impedance was 0.84. The mean of an impedance difference was 1.6 ± 4.8 Ω (minimum - 11 and maximum 8). Postimplant CXR was available for 33 out of 37 patients (89.2%). The PRAETORIAN score was less than 90 in all patients and the mean score was 32.7 ± 8.8. CONCLUSION: We demonstrated that 10 J shock impedance in SR correlated well with 65 J defibrillation impedance during IM S-ICD implantation. An IM implantation technique provides excellent generator location on postimplant CXR. The IM technique combined with 10 J shock in SR may be sufficient to predict and ensure the defibrillation efficacy of the S-ICD.


Assuntos
Desfibriladores Implantáveis , Adulto , Arritmias Cardíacas , Cardioversão Elétrica , Impedância Elétrica , Humanos , Masculino , Pessoa de Meia-Idade , Ohio , Tela Subcutânea
6.
J Cardiovasc Electrophysiol ; 30(11): 2453-2459, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31502324

RESUMO

BACKGROUND: An internal risk stratification algorithm was developed to decrease the risk of major adverse cardiac events (MACEs) during lead extractions (LEs). OBJECTIVE: To report upon the impact of a risk stratification algorithm (RISE [RIsk Stratification prior to lead Extraction] protocol) on outcomes of LEs in a high-volume center. METHODS: A retrospective review of a prospectively maintained LEs database was performed to identify features associated with MACEs. On the basis of the retrospective data, the RISE protocol differentiated LEs procedures into "High" and "Low" risk for occurrence of MACEs. High-risk LEs included dual-coil defibrillator lead (≥3 years), pacemaker and single-coil lead (≥5 years), and any StarFix coronary sinus lead. During the prospective evaluation of the RISE protocol, "High-risk" LEs were performed in an operating room (OR) or hybrid laboratory with the cardiac anesthesiologist, OR nursing team, perfusionist in the room, and a cardiac surgeon on the premises. "Low-risk" LEs were performed in the electrophysiology (EP) laboratory with anesthesia provided by EP nursing team. The preintervention (pre-RISE) and postintervention (post-RISE) group spanned 19 and 40 months and consisted of 449 (632 leads) and 751 patients (1055 leads), respectively. The primary outcome of MACEs in the two groups was compared. RESULTS: Protocol compliance was 100%. The primary outcome of MACEs occurred in 15 patients (3.34%) before and 12 (1.6%) after implementation of the RISE protocol (P = .04). CONCLUSION: RISE identified a low-risk group where minimal resources are needed and allowed for rapid intervention in the high-risk group that reduced the consequences of MACEs.


Assuntos
Protocolos Clínicos , Desfibriladores Implantáveis , Remoção de Dispositivo/efeitos adversos , Marca-Passo Artificial , Complicações Pós-Operatórias/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Bases de Dados Factuais , Remoção de Dispositivo/mortalidade , Feminino , Hospitais com Alto Volume de Atendimentos , Humanos , Masculino , Pessoa de Meia-Idade , Ohio , Complicações Pós-Operatórias/mortalidade , Estudos Prospectivos , Desenho de Prótese , Melhoria de Qualidade , Indicadores de Qualidade em Assistência à Saúde , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
7.
J Cardiovasc Electrophysiol ; 30(5): 792-799, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30834611

RESUMO

BACKGROUND: Central sleep apnea (CSA) is a breathing disorder caused by the intermittent absence of central respiratory drive. Transvenous phrenic nerve stimulation is a new therapeutic option, recently approved by the FDA , for the treatment of CSA. OBJECTIVE: To describe the technique used to implant the transvenous phrenic nerve stimulation system (the remede System, Respicardia, Inc). METHODS: The remede System is placed in the pectoral region, typically on the right side. A single stimulation lead is placed in either the left pericardiophrenic vein (PPV) or the right brachiocephalic vein (RBC). A sensing lead is placed into the azygous vein to detect respiration. RESULTS: In the remede System Pivotal trial, 147 of 151 (97%) patients were successfully implanted with the system. Sixty-two percent of stimulation leads were placed in the PPV and 35% in the RBC. Mean procedure time was 2.7 ± 0.8 hours and 94% of patients were free from implant-related serious adverse events through 6 months. CONCLUSION: In patients with CSA, transvenous phrenic nerve stimulation is an effective and safe therapy with an implant procedure similar to that of cardiac implantable electronic devices.


Assuntos
Diafragma/inervação , Terapia por Estimulação Elétrica/instrumentação , Neuroestimuladores Implantáveis , Nervo Frênico/fisiopatologia , Implantação de Prótese , Respiração , Apneia do Sono Tipo Central/terapia , Terapia por Estimulação Elétrica/efeitos adversos , Humanos , Duração da Cirurgia , Desenho de Prótese , Implantação de Prótese/efeitos adversos , Apneia do Sono Tipo Central/diagnóstico , Apneia do Sono Tipo Central/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
8.
Pacing Clin Electrophysiol ; 42(1): 58-62, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30414285

RESUMO

BACKGROUND: Lead dislodgement (LD) is a well-recognized complication during implantation of cardiac implantable electronic devices (CIEDs). An intraprocedural protocol, referred to as reduction of LD protocol, was developed to reduce the risk of LD. METHODS: The protocol involved (1) inserting a straight stylet down the right atrial lead and applying forward pressure while monitoring for fluoroscopic stability, (2) visualizing all leads during deep inspiration to determine if there is adequate lead redundancy, and (3) having the patient take a deep breath and cough while pacing just at capture threshold to assess for loss of capture in each lead. Any intraprocedural change in the parameters fulfilling the predefined criteria for inadequate lead implantation prompted lead repositioning. Data regarding demographic factors, clinical characteristics, and incidence of LD in the first 30 days after implant was obtained from intramural CIED database. The preintervention (control) group spanned 27 months and consisted of a total of 4,294 leads while the postintervention (intervention) group spanned 17 months and consisted of 2,361 leads implanted. RESULTS: There was no significant difference in the demographic factors and clinical characteristics in the two groups. Protocol compliance was > 90%. There were 44 occurrences of LD (1.02%) before and 10 (0.4%) after implementation of the protocol. The protocol significantly reduced the incidence of LD during the 30 days after implant (P = 0.014). No clinical characteristic predicted the risk of LD. CONCLUSION: Intraprocedural maneuvers performed to assess the adequacy of lead implantation results in reduced risk of LD.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Eletrodos Implantados , Falha de Equipamento , Complicações Pós-Operatórias/prevenção & controle , Idoso , Eletrocardiografia , Feminino , Fluoroscopia , Humanos , Masculino , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco
9.
Pacing Clin Electrophysiol ; 42(12): 1552-1557, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31702059

RESUMO

BACKGROUND: The perioperative anesthesia care during subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation is still evolving. OBJECTIVE: To assess the feasibility and safety of S-ICD implantation with monitored anesthesia care (MAC) versus general anesthesia (GA) in a tertiary care center. METHODS: This is a single-center retrospective study of patients undergoing S-ICD implantation between October 2012 and May 2019. Patients were categorized into MAC and GA group based on the mode of anesthesia. Procedural success without escalation to GA was the primary endpoint of the study, whereas intraprocedural hemodynamics, need of pharmacological support for hypotension and bradycardia, length of the procedure, stay in the post-anesthesia care unit, and postoperative pain were assessed as secondary endpoints. RESULTS: The study comprises 287 patients with MAC in 111 and GA in 176 patients. Compared to MAC, patients in GA group were younger and had a higher body mass index. All patients had successful S-ICD implantation. Only one patient (0.9%) in the MAC group was converted to GA. Despite a similar baseline heart rate (HR) and mean arterial blood pressure (MAP) in both groups, patients with GA had significantly lower HR and MAP during the procedure and more frequently required pharmacological hemodynamic support. Length of the procedure, stay in the postanesthesia care unit, and postoperative pain was similar in both groups. CONCLUSION: This retrospective experience suggests that implantation of S-ICD is feasible and safe with MAC. Use of GA is associated with more frequent administration of hemodynamic drugs during S-ICD implantation.


Assuntos
Anestesia/métodos , Desfibriladores Implantáveis , Implantação de Prótese/métodos , Anestesia Geral , Anestesia Local , Bradicardia/tratamento farmacológico , Estudos de Viabilidade , Feminino , Hemodinâmica , Humanos , Hipotensão/tratamento farmacológico , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Medição da Dor , Dor Pós-Operatória/prevenção & controle , Estudos Retrospectivos
10.
J Cardiovasc Electrophysiol ; 29(10): 1460-1466, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29964312

RESUMO

BACKGROUND: Cardiac implantable electronic device (CIED) infections associated with large, mobile vegetation adds to the complexity of lead extraction and is associated with significant patient morbidity and mortality. OBJECTIVE: To show the feasibility of concomitant cardiovascular implantable electronic device extraction and vacuum-assisted removal of lead-related vegetations. METHODS: This is a single-center retrospective case series of consecutive patients with persistent bacteremia, sepsis, or endocarditis despite medical therapy who have vegetations >2 cm and subsequently underwent immediate CIED lead extraction after debulking with vacuum-assisted suction. RESULTS: Eight patients underwent successful removal of 17 leads immediately after debulking of vegetations with vacuum-assisted device suction. Debulking procedure was not successful in 1 patient due to inability to direct the vacuum suction device into proper position. There were no intraprocedure complications related to the vacuum-assisted debulking. One patient required open sternotomy for tear of the coronary sinus ostium related to extraction of a left ventricular pacing electrode. There was no mortality within 30 days of the procedure. CONCLUSIONS: Based upon these clinical results, it is feasible for patients with infected CIED systems that have large right-sided vegetations to undergo vacuum-assisted debulking then immediately followed by percutaneous CIED removal in whom surgical removal is considered high risk.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/instrumentação , Procedimentos Cirúrgicos de Citorredução/métodos , Remoção de Dispositivo/métodos , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Infecções Relacionadas à Prótese/terapia , Adulto , Idoso , Procedimentos Cirúrgicos de Citorredução/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Ecocardiografia Transesofagiana , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Sucção , Resultado do Tratamento , Vácuo , Adulto Jovem
12.
Pacing Clin Electrophysiol ; 41(5): 504-510, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29476660

RESUMO

BACKGROUND: Atrioventricular junctional (AVJ) ablation and pacemaker implantation are indicated when pharmacotherapy fails to achieve adequate rate control in atrial fibrillation (AF). The purpose of our study is to assess the feasibility and safety of concurrent Micra leadless transcatheter pacemaker implantation and AVJ ablation. METHODS: We retrospectively assessed patients who underwent Micra implantation and concurrent AVJ ablation at three institutions between August 2014 and March 2016. All patients and devices were followed at baseline and at 1, 3, 6, and 12 months postimplantion. RESULTS: Twenty-one patients with permanent AF (median age 77 [range: 62-88], female 15 [71.4%]) underwent successful Micra implantation followed by concurrent AVJ ablation. There was no device dislodgement or malfunction during the 12-month follow-up. Complete 12-month electrical performance data were available in 14 patients (67%). Among patients with the complete data set, median pacing thresholds at implant and at 1, 3, 6, and 12 months were 0.5 V (range: 0.25-0.88), 0.44 V (range: 0.25-2.0), 0.5 V (range: 0.25-1.63), 0.5 V (range: 0.25-1.13), and 0.5 V (range: 0.25-1.13) at a pulse width of 0.24 msec, respectively. Two patients died due to noncardiac causes during follow-up. There were no patients with major device-related complications. CONCLUSIONS: Concurrent Micra implantation and AVJ ablation is feasible and appears safe. There was no device dislodgement, malfunction, or significant pacing threshold rise requiring device reimplantation during the 12-month follow-up. This combined approach can be considered for patients with AF with suboptimal rate control who have failed AF catheter ablation and/or pharmacotherapy.


Assuntos
Fibrilação Atrial/cirurgia , Nó Atrioventricular/cirurgia , Ablação por Cateter/métodos , Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/fisiopatologia , Nó Atrioventricular/fisiopatologia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
15.
Heart Rhythm ; 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38797310

RESUMO

BACKGROUND: Peridevice leak (PDL) after left atrial appendage closure (LAAC) portends adverse outcomes. OBJECTIVE: The purpose of this study was to assess the incidence, predictors, clinical implications, and temporal evolution of PDL after LAAC. METHODS: This single-center retrospective study included all patients who underwent LAAC with Watchman FLX and had no PDL detected at the time of implantation. The primary end point was the incidence of new PDL at initial imaging. The composite secondary end point included continued oral anticoagulation after initial imaging, device-related thrombus, stroke or transient ischemic attack, major bleeding, and need for PDL closure at longest follow-up. Temporal evolution of PDL was assessed in patients with available surveillance imaging. RESULTS: Of the 355 patients who completed imaging at 47 days (interquartile range [IQR] 44-50 days), 139 (39%) had new PDL with a mean leak size of 3.2 ± 1.4 mm (median 3.0 mm; IQR 2.0-4.0 mm; range 1.0-9.0 mm). Multiple deployment attempts and larger device size were positive predictors of PDL, while increased contrast volume administration was a negative predictor of PDL. The composite secondary end point occurred in 42 (30%) patients with PDL and 33 (15%) patients without PDL (P < .001). Of the 139 patients with PDL, 43 (31%) had surveillance imaging where the leak size regressed from 3.7 ± 1.8 mm at 46 days (IQR 44-51 days) to 1.7 ± 2.0 mm at 189 days (IQR 158-285 days) (P < .001). The leak size regressed in 33 (77%), remained stable in 4 (9%), and progressed in 6 (14%) cases. CONCLUSION: Despite design improvements, LAAC with Watchman FLX demonstrates a significant incidence of PDL with meaningful clinical implications. Regardless of initial size, most leaks regressed over time.

16.
Heart Rhythm ; 20(1): 122-133, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36113768

RESUMO

The sinoatrial node (SAN) is the primary pacemaker of the human heart. It is a single, elongated, 3-dimensional (3D) intramural fibrotic structure located at the junction of the superior vena cava intercaval region bordering the crista terminalis (CT). SAN activation originates in the intranodal pacemakers and is conducted to the atria through 1 or more discrete sinoatrial conduction pathways. The complexity of the 3D SAN pacemaker structure and intramural conduction are underappreciated during clinical multielectrode mapping and ablation procedures of SAN and atrial arrhythmias. In fact, defining and targeting SAN is extremely challenging because, even during sinus rhythm, surface-only multielectrode mapping may not define the leading pacemaker sites in intramural SAN but instead misinterpret them as epicardial or endocardial exit sites through sinoatrial conduction pathways. These SAN exit sites may be distributed up to 50 mm along the CT beyond the ∼20-mm-long anatomic SAN structure. Moreover, because SAN reentrant tachycardia beats may exit through the same sinoatrial conduction pathway as during sinus rhythm, many SAN arrhythmias are underdiagnosed. Misinterpretation of arrhythmia sources and/or mechanisms (eg, enhanced automaticity, intranodal vs CT reentry) limits diagnosis and success of catheter ablation treatments for poorly understood SAN arrhythmias. The aim of this review is to provide a state-of-the-art overview of the 3D structure and function of the human SAN complex, mechanisms of SAN arrhythmias and available approaches for electrophysiological mapping, 3D structural imaging, pharmacologic interventions, and ablation to improve diagnosis and mechanistic treatment of SAN and atrial arrhythmias.


Assuntos
Fibrilação Atrial , Nó Sinoatrial , Humanos , Sistema de Condução Cardíaco/fisiologia , Veia Cava Superior , Átrios do Coração
17.
J Innov Card Rhythm Manag ; 14(4): 5403-5409, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37143575

RESUMO

Persistent left superior vena cava (PLSVC) is the most common congenital thoracic venous anomaly, with 0.47% of patients undergoing pacemaker or cardiac implantable device placement found to have PLSVC. This review article describes challenges and interventions to successfully insert cardiac implantable electronic device leads into patients with PLSVC by providing multiple unique case examples.

18.
J Innov Card Rhythm Manag ; 12(6): 4562-4568, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34234991

RESUMO

As leadless pacing (LP) use is expected to increase, it becomes increasingly essential that operators become familiar with the tools and techniques needed to retrieve an LP successfully. The purpose of this review is to describe a stepwise approach for the successful retrieval of tine-based LP devices, including ways to minimize complications.

19.
JACC Clin Electrophysiol ; 7(6): 745-754, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33516715

RESUMO

OBJECTIVES: This study reports resource use and economic implications of rhythm monitoring with subcutaneous cardiac rhythm monitors (SCRMs). BACKGROUND: SCRMs generate a substantial amount of data that requires timely adjudication for appropriate clinical care. Resource use for SCRM monitoring is not known. METHODS: The study included consecutive transmissions during 4 weeks from 1,811 SCRMs. Resource use was quantified by assessment of time commitment of device clinic personnel and electrophysiologists for data adjudication. Incidence and characteristics of false positive (FP) episodes were assessed. Impact of custom programming for arrhythmia detection on incidence of FP episodes and resource use was analyzed. RESULTS: A total of 1,457 transmissions (alerts = 462; full downloads = 995) were received during study period. Average device clinic personnel time for adjudication of 1 transmission was 15 ± 6 min. This totaled to 364 h spent (2.3 full-time staff) over the 4-week period, which translated into a salary cost of $12,000 U.S. dollars (USD). Average time spent by an electrophysiologist for 1 transmission was 1.5 ± 1 min and totaled to 37 h for 4 weeks, which translated into an estimated cost of $9,600 USD. Of 1,457 total transmissions, 512 (35%) represented multiple transmissions from the same patients, which resulted in no additional reimbursement. Incidence of FP episodes in the entire cohort was 50% and was variable in alert (60%) and full download (49%) (p = 0.04) transmissions. When SCRMs with manufacturer suggested nominal programming and institutional custom programming were compared, there was a reduction in FP episodes (55% vs. 16%; p = 0.01), which translated to a 34% reduction in resource use for data adjudication. CONCLUSIONS: SCRM data adjudication requires significant resources. Custom programming for SCRMs may overcome the data deluge.


Assuntos
Desfibriladores Implantáveis , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Humanos , Incidência , Monitorização Fisiológica
20.
JACC Clin Electrophysiol ; 6(10): 1318-1331, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-33092762

RESUMO

Leadless pacemakers (LPs) have emerged as a meaningful alternative to transvenous pacemakers for single-ventricular pacing. LPs eliminate many of lead- and pocket-associated complications observed with transvenous pacemakers. Owing to the lack of atrioventricular synchronous pacing until recently, the use of LP was generally reserved for those patients who either required minimal ventricular pacing or had permanent atrial fibrillation. The only commercially available LP is the Micra transcatheter pacing system (Micra-TPS, Medtronic Inc. Fridley, Minnesota), which requires insertion of a 27-F (outer diameter) introducer sheath in the femoral vein. The LP is delivered to the right ventricle using a 23-F delivery catheter. Owing to the need for a large-bore sheath, the pivotal studies for the Micra transcatheter pacing system excluded patients with indwelling inferior vena cava filters and included only a few patients with bioprosthetic or repaired tricuspid valve. Subsequent real-world experience has demonstrated the overall safety and feasibility of LP placement, and use in various unconventional clinical settings has been validated, albeit with specific precautions. Additionally, incorporation of adjunctive techniques and strategies can improve the safety of the procedure in routine clinical settings as well. The objective of this state-of-the-art review is to highlight the key procedural elements to facilitate safe and efficient implantation of LP in routine as well as in unique clinical settings.


Assuntos
Fibrilação Atrial , Marca-Passo Artificial , Estimulação Cardíaca Artificial , Humanos , Minnesota , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA