Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 121
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Magn Reson ; 25(1): 46, 2023 08 10.
Artigo em Inglês | MEDLINE | ID: mdl-37563646

RESUMO

BACKGROUND: Late gadolinium enhancement (LGE) is a valuable part of cardiac magnetic resonance imaging (CMR). In particular, inversion-recovery imaging of LGE, with nulling of the signal from reference areas of myocardium, can have a distinctive pattern in some patients with cardiac amyloid, including both diffuse (relatively faint) subendocardial LGE and a relatively dark appearance of the blood. However, the underlying reasons for this distinctive appearance have not previously been well investigated. Pharmacokinetic modeling of myocardial contrast enhancement kinetics can potentially provide insight into the mechanisms of the distinctive LGE appearance that can be seen in cardiac amyloid, as well as why it may be unreliable in some patients. METHODS: An interactive three-compartment pharmacokinetic model of the dynamics of myocardial contrast enhancement in CMR was implemented, and used to simulate LGE dynamics in normal, scar, and cardiac amyloid myocardium; the results were compared with previously published values. RESULTS: The three-compartment model is able to capture the qualitative features of LGE, in patients with cardiac amyloid. In particular, the characteristic "dark blood" appearance of PSIR images of LGE in cardiac amyloid is seen to likely primarily reflect expansion of the extravascular extracellular space (EES) by amyloid in the "reference" myocardium; the cardiac amyloid contrast enhancement dynamics also reflect expansion of the body EES. CONCLUSION: The distinctive appearance of LGE in cardiac amyloid is likely due to a combination of diffuse expansion by amyloid of the EES of the reference myocardium and of the body EES.


Assuntos
Meios de Contraste , Gadolínio , Humanos , Cinética , Valor Preditivo dos Testes , Imageamento por Ressonância Magnética/métodos , Miocárdio/patologia
2.
NMR Biomed ; 34(7): e4534, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34002901

RESUMO

Current clinical MRI evaluation of musculature largely focuses on nonquantitative assessments (including T1-, T2- and PD-weighted images), which may vary greatly between imaging systems and readers. This work aims to determine the efficacy of a quantitative approach to study the microstructure of muscles at the cellular level with the random permeable barrier model (RPBM) applied to time-dependent diffusion tensor imaging (DTI) for varying diffusion time. Patients (N = 15, eight males and seven females) with atrophied calf muscles due to immobilization of one leg in a nonweight-bearing cast, were enrolled after providing informed consent. Their calf muscles were imaged with stimulated echo diffusion for DTI, T1-mapping and RPBM modeling. Specifically, After cast removal, both calf muscles (atrophied and contralateral control leg) were imaged with MRI for all patients, with follow-up scans to monitor recovery of the atrophied leg for six patients after 4 and 8 weeks. We compare RPBM-derived microstructural metrics: myofiber diameter, a, and sarcolemma permeability, κ, along with macroscopic anatomical parameters (muscle cross-sectional area, fiber orientation, <θ>, and T1 relaxation). ROC analysis was used to compare parameters between control and atrophied muscle, while the Friedman test was used to evaluate the atrophied muscle longitudinally. We found that the RPBM framework enables measurement of microstructural parameters from diffusion time-dependent DTI, of which the myofiber diameter is a stronger predictor of intramuscular morphological changes than either macroscopic (anatomical) measurements or empirical diffusion parameters. This work demonstrates the potential of RPBM to assess pathological changes in musculature that seem undetectable with standard diffusion and anatomical MRI.


Assuntos
Imagem de Tensor de Difusão , Fibras Musculares Esqueléticas/patologia , Atrofia Muscular/diagnóstico por imagem , Adulto , Anisotropia , Área Sob a Curva , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
3.
MAGMA ; 33(5): 613-626, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32152793

RESUMO

OBJECTIVES: To investigate the potential value of adding a tagged three-chamber (3Ch) cine to clinical hypertrophic cardiomyopathy (HCM) magnetic resonance imaging (MRI) protocols, including to help distinguish HCM patients with regionally impaired cardiac function. METHODS: Forty-eight HCM patients, five patients with "septal knuckle" (SK), and 20 healthy volunteers underwent MRI at 1.5T; a tagged 3Ch cine was added to the protocol. Regional strain, myocardial wall thickness, and mitral valve leaflet lengths were measured in the 3Ch view. RESULTS: In HCM, we found a reduced tangential strain with decreased diastolic relaxation in both hypertrophied (p = 0.003) and remote segments (p = 0.035). Strain in the basal septum correlated with the length of the coaptation zone + residual leaflet (r = 0.48, p < 0.001). In the basal free wall, patients with SK had faster relaxation compared to HCM patients with septal hypertrophy. DISCUSSION: The 3Ch tagged MRI sequence provides useful information for the examination of suspected HCM patients, with minimal additional time cost. Local wall function is closely associated with morphological changes of the mitral apparatus measured in the same plane and may provide insights into mechanisms of obstruction. The additional strain information may be helpful when analyzing local myocardial wall motion patterns in the presence of SK.


Assuntos
Cardiomiopatia Hipertrófica , Imagem Cinética por Ressonância Magnética , Cardiomiopatia Hipertrófica/patologia , Feminino , Fibrose , Humanos , Imageamento por Ressonância Magnética , Miocárdio/patologia
5.
Eur Radiol ; 28(11): 4586-4597, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29721687

RESUMO

OBJECTIVES: To determine whether use of a stylus user input device (UID) would be superior to a mouse for CMR segmentation. METHODS: Twenty-five consecutive clinical cardiac magnetic resonance (CMR) examinations were selected. Image analysis was independently performed by four observers. Manual tracing of left (LV) and right (RV) ventricular endocardial contours was performed twice in 10 randomly assigned sessions, each session using only one UID. Segmentation time and the ventricular function variables were recorded. The mean segmentation time and time reduction were calculated for each method. Intraclass correlation coefficients (ICC) and Bland-Altman plots of function variables were used to assess intra- and interobserver variability and agreement between methods. Observers completed a Likert-type questionnaire. RESULTS: The mean segmentation time (in seconds) was significantly less with the stylus compared to the mouse, averaging 206±108 versus 308±125 (p<0.001) and 225±140 versus 353±162 (p<0.001) for LV and RV segmentation, respectively. The intra- and interobserver agreement rates were excellent (ICC≥0.75) regardless of the UID. There was an excellent agreement between measurements derived from manual segmentation using different UIDs (ICC≥0.75), with few exceptions. Observers preferred the stylus. CONCLUSION: The study shows a significant reduction in segmentation time using the stylus, a subjective preference, and excellent agreement between the methods. KEY POINTS: • Using a stylus for MRI ventricular segmentation is faster compared to mouse • A stylus is easier to use and results in less fatigue • There is excellent agreement between stylus and mouse UIDs.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/instrumentação , Animais , Desenho de Equipamento , Feminino , Humanos , Masculino , Camundongos , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes
6.
MAGMA ; 31(1): 49-59, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29067539

RESUMO

OBJECTIVES: Residual respiratory motion degrades image quality in conventional cardiac cine MRI (CCMRI). We evaluated whether a free-breathing (FB) radial imaging CCMRI sequence with compressed sensing reconstruction [extradimensional (e.g. cardiac and respiratory phases) golden-angle radial sparse parallel, or XD-GRASP] could provide better image quality than a conventional Cartesian breath-held (BH) sequence in an unselected population of patients undergoing clinical CCMRI. MATERIALS AND METHODS: One hundred one patients who underwent BH and FB imaging in a midventricular short-axis plane at a matching location were included. Visual and quantitative image analysis was performed by two blinded experienced readers, using a five-point qualitative scale to score overall image quality and visual signal-to-noise ratio (SNR) grade, with measures of noise and sharpness. End-diastolic and end-systolic left ventricular areas were also measured and compared for both BH and FB images. RESULTS: Image quality was generally better with the BH cines (overall quality grade for BH vs FB images 4 vs 2.9, p < 0.001; noise 0.06 vs 0.08 p < 0.001; SNR grade 4.1 vs 3, p < 0.001), except for sharpness (p = 0.48). There were no significant differences between BH and FB images regarding end-diastolic or end-systolic areas (p = 0.35 and p = 0.12). Eighteen of the 101 patients had poor BH image quality (grade 1 or 2). In this subgroup, the quality of the FB images was better (p = 0.0032), as was the SNR grade (p = 0.003), but there were no significant differences regarding noise and sharpness (p = 0.45 and p = 0.47). CONCLUSION: Although FB XD-GRASP CCMRI was visually inferior to conventional BH CCMRI in general, it provided improved image quality in the subgroup of patients with respiratory-motion-induced artifacts on BH images.


Assuntos
Técnicas de Imagem Cardíaca/métodos , Imagem Cinética por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Suspensão da Respiração , Técnicas de Imagem Cardíaca/estatística & dados numéricos , Criança , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/estatística & dados numéricos , Imagem Cinética por Ressonância Magnética/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Mecânica Respiratória , Estudos Retrospectivos , Razão Sinal-Ruído , Adulto Jovem
8.
J Magn Reson Imaging ; 46(5): 1263-1280, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28471530

RESUMO

Contraction of the heart is central to its purpose of pumping blood around the body. While simple global function measures (such as the ejection fraction) are most commonly used in the clinical assessment of cardiac function, MRI also provides a range of approaches for quantitatively characterizing regional cardiac function, including the local deformation (or strain) within the heart wall. While they have been around for some years, these methods are still undergoing further technical development, and they have had relatively little clinical evaluation. However, they can provide potentially useful new ways to assess cardiac function, which may be able to contribute to better classification and treatment of heart disease. This article provides some basic background on the physical and physiological factors that determine the motion of the heart, in health and disease and then reviews some of the ways that MRI methods are being developed to image and quantify strain within the myocardium. LEVEL OF EVIDENCE: 4 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2017;46:1263-1280.


Assuntos
Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Miocárdio/patologia , Algoritmos , Animais , Cardiologia , Cardiomiopatias/diagnóstico por imagem , Ecocardiografia , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Movimento (Física) , Contração Miocárdica/fisiologia , Isquemia Miocárdica/diagnóstico por imagem , Imagens de Fantasmas , Estresse Mecânico
9.
Magn Reson Med ; 75(2): 775-88, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25809847

RESUMO

PURPOSE: To develop a novel framework for free-breathing MRI called XD-GRASP, which sorts dynamic data into extra motion-state dimensions using the self-navigation properties of radial imaging and reconstructs the multidimensional dataset using compressed sensing. METHODS: Radial k-space data are continuously acquired using the golden-angle sampling scheme and sorted into multiple motion-states based on respiratory and/or cardiac motion signals derived directly from the data. The resulting undersampled multidimensional dataset is reconstructed using a compressed sensing approach that exploits sparsity along the new dynamic dimensions. The performance of XD-GRASP is demonstrated for free-breathing three-dimensional (3D) abdominal imaging, two-dimensional (2D) cardiac cine imaging and 3D dynamic contrast-enhanced (DCE) MRI of the liver, comparing against reconstructions without motion sorting in both healthy volunteers and patients. RESULTS: XD-GRASP separates respiratory motion from cardiac motion in cardiac imaging, and respiratory motion from contrast enhancement in liver DCE-MRI, which improves image quality and reduces motion-blurring artifacts. CONCLUSION: XD-GRASP represents a new use of sparsity for motion compensation and a novel way to handle motions in the context of a continuous acquisition paradigm. Instead of removing or correcting motion, extra motion-state dimensions are reconstructed, which improves image quality and also offers new physiological information of potential clinical value.


Assuntos
Abdome , Bloqueio Atrioventricular/fisiopatologia , Compressão de Dados/métodos , Imageamento por Ressonância Magnética/métodos , Complexos Ventriculares Prematuros/fisiopatologia , Adulto , Técnicas de Imagem de Sincronização Cardíaca , Meios de Contraste , Feminino , Voluntários Saudáveis , Humanos , Aumento da Imagem/métodos , Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Técnicas de Imagem de Sincronização Respiratória
10.
J Cardiovasc Magn Reson ; 18(1): 83, 2016 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-27884152

RESUMO

BACKGROUND: Arrhythmia can significantly alter the image quality of cardiovascular magnetic resonance (CMR); automatic detection and sorting of the most frequent types of arrhythmias during the CMR acquisition could potentially improve image quality. New CMR techniques, such as non-Cartesian CMR, can allow self-gating: from cardiac motion-related signal changes, we can detect cardiac cycles without an electrocardiogram. We can further use this data to obtain a surrogate for RR intervals (valley intervals: VV). Our purpose was to evaluate the feasibility of an automated method for classification of non-arrhythmic (NA) (regular cycles) and arrhythmic patients (A) (irregular cycles), and for sorting of common arrhythmia patterns between atrial fibrillation (AF) and premature ventricular contraction (PVC), using the cardiac motion-related signal obtained during self-gated free-breathing radial cardiac cine CMR with compressed sensing reconstruction (XD-GRASP). METHODS: One hundred eleven patients underwent cardiac XD-GRASP CMR between October 2015 and February 2016; 33 were included for retrospective analysis with the proposed method (6 AF, 8 PVC, 19 NA; by recent ECG). We analyzed the VV, using pooled statistics (histograms) and sequential analysis (Poincaré plots), including the median (medVV), the weighted mean (meanVV), the total number of VV values (VVval), and the total range (VVTR) and half range (VVHR) of the cumulative frequency distribution of VV, including the median to half range (medVV/VVHR) and the half range to total range (VVHR/VVTR) ratios. We designed a simple algorithm for using the VV results to differentiate A from NA, and AF from PVC. RESULTS: Between NA and A, meanVV, VVval, VVTR, VVHR, medVV/VVHR and VVHR/VVTR ratios were significantly different (p values = 0.00014, 0.0027, 0.000028, 5×10-9, 0.002, respectively). Between AF and PVC, meanVV, VVval and medVV/VVHR ratio were significantly different (p values = 0.018, 0.007, 0.044, respectively). Using our algorithm, sensitivity, specificity, and accuracy were 93 %, 95 % and 94 % to discriminate between NA and A, and 83 %, 71 %, and 77 % to discriminate between AF and PVC, respectively; areas under the ROC curve were 0.93 and 0.89. CONCLUSIONS: Our study shows we can reliably detect arrhythmias and differentiate AF from PVC, using self-gated cardiac cine XD-GRASP CMR.


Assuntos
Algoritmos , Fibrilação Atrial/diagnóstico por imagem , Técnicas de Imagem de Sincronização Cardíaca , Eletrocardiografia , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Complexos Ventriculares Prematuros/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Fibrilação Atrial/classificação , Fibrilação Atrial/fisiopatologia , Estudos de Viabilidade , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Mecânica Respiratória , Estudos Retrospectivos , Complexos Ventriculares Prematuros/classificação , Complexos Ventriculares Prematuros/fisiopatologia , Adulto Jovem
11.
Echocardiography ; 32(5): 875-7, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25418608

RESUMO

Persistent fifth arch (PFA) is a rare anomaly that is often underdiagnosed and missed. Different PFA types that have been reported in the literature are systemic-to-systemic type (most common), systemic-to-pulmonary artery (PA), and PA-to-systemic types. The designations of systemic-to-PA or PA-to-systemic are based on if the PFA is a source of PA or systemic blood flow, respectively, in the setting of critical proximal obstruction (pulmonary atresia or aortic atresia). This case describes an unusual PFA, which connects the distal PA to distal ascending aorta; however, it is not associated with critical proximal obstruction, and while it appeared to be an incidental finding in early gestation, progressive serial distal obstruction of the left fourth arch was seen to develop. This case highlights that prenatal diagnosis of PFA is possible and that once a diagnosis is made, serial fetal echocardiograms should be performed to evaluate for evolving lesions.


Assuntos
Aorta/anormalidades , Aorta/diagnóstico por imagem , Coartação Aórtica/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Artéria Pulmonar/diagnóstico por imagem , Ultrassonografia Pré-Natal , Aorta/cirurgia , Coartação Aórtica/cirurgia , Doenças da Aorta/complicações , Doenças da Aorta/cirurgia , Feminino , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Humanos , Gravidez , Artéria Pulmonar/anormalidades
12.
Pediatr Cardiol ; 36(6): 1294-300, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25835201

RESUMO

The aim is to compare tricuspid valve (TV) atrioventricular junction (AVJ) annular motion parameters in unrepaired atrial septal defect (ASD) and repaired Tetralogy of Fallot (TOF) by cardiac magnetic resonance (CMR) imaging. We retrospectively reviewed CMR studies performed between November 2007 and November 2013 in patients 16-45 years of age with unrepaired ASD (with or without partial anomalous pulmonary venous return) and with repaired TOF, who had previous infundibulotomy, but have not undergone pulmonary valve replacement. Longitudinal motion of lateral TV in four-chamber view cine image was tracked through the cardiac cycle with custom software. Twenty TOF patients and 12 ASD patients were included, and values were compared with 80 controls. Right ventricular end-diastolic volume index and right ventricular end-systolic volume index were similar in the ASD and TOF groups and were significantly higher in both groups than in controls. Maximum displacement of the TV in systole, velocity at half-maximal displacement during systole, and velocity at half-maximal displacement during early diastole were all significantly lower in the TOF group than the ASD group [1.39 ± 0.47 vs. 2.21 ± 0.46 (cm, p < 0.01), 5.9 ± 2.1 vs. 10.1 ± 2.3 (cm/s, p < 0.01), and 7.7 ± 2.6 vs. 10.9 ± 3.1 (cm/s, p < 0.05)]. TOF patients have diminished early diastolic TV AVJ velocity compared to patients with an unrepaired ASD, despite similar RV volumes. This observation could suggest diastolic dysfunction or cardiac mechanics unique to the postoperative, volume-overloaded right ventricle in patients with repaired TOF.


Assuntos
Comunicação Interatrial/fisiopatologia , Ventrículos do Coração/patologia , Imageamento por Ressonância Magnética , Tetralogia de Fallot/cirurgia , Valva Tricúspide/fisiopatologia , Função Ventricular Direita , Adolescente , Adulto , Velocidade do Fluxo Sanguíneo , Procedimentos Cirúrgicos Cardíacos/métodos , Ecocardiografia , Feminino , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/patologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Volume Sistólico , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/patologia , Tetralogia de Fallot/fisiopatologia , Valva Tricúspide/diagnóstico por imagem , Adulto Jovem
13.
Magn Reson Med ; 72(3): 707-17, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24142845

RESUMO

PURPOSE: To develop a fast and flexible free-breathing dynamic volumetric MRI technique, iterative Golden-angle RAdial Sparse Parallel MRI (iGRASP), that combines compressed sensing, parallel imaging, and golden-angle radial sampling. METHODS: Radial k-space data are acquired continuously using the golden-angle scheme and sorted into time series by grouping an arbitrary number of consecutive spokes into temporal frames. An iterative reconstruction procedure is then performed on the undersampled time series where joint multicoil sparsity is enforced by applying a total-variation constraint along the temporal dimension. Required coil-sensitivity profiles are obtained from the time-averaged data. RESULTS: iGRASP achieved higher acceleration capability than either parallel imaging or coil-by-coil compressed sensing alone. It enabled dynamic volumetric imaging with high spatial and temporal resolution for various clinical applications, including free-breathing dynamic contrast-enhanced imaging in the abdomen of both adult and pediatric patients, and in the breast and neck of adult patients. CONCLUSION: The high performance and flexibility provided by iGRASP can improve clinical studies that require robustness to motion and simultaneous high spatial and temporal resolution. Magn Reson Med 72:707-717, 2014. © 2013 Wiley Periodicals, Inc.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Abdome , Adulto , Doenças Mamárias/diagnóstico , Pré-Escolar , Meios de Contraste , Compressão de Dados/métodos , Feminino , Gadolínio DTPA , Neoplasias de Cabeça e Pescoço/diagnóstico , Humanos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Hepatopatias/diagnóstico , Masculino , Pessoa de Meia-Idade , Esclerose Tuberosa/diagnóstico
14.
J Magn Reson Imaging ; 39(5): 1301-7, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24719241

RESUMO

PURPOSE: To assess liver stiffness using magnetization-tagged magnetic resonance imaging (MRI) to measure the cardiac-induced motion in the liver of cirrhosis patients with known Child-Pugh scores. MATERIALS AND METHODS: Tagged MRI was performed using a 3T MR scanner on 52 cirrhosis patients classified into two groups: liver cirrhosis with Child-Pugh A (LCA; n = 39) and liver cirrhosis with Child-Pugh B or C (LCBC; n = 13). We also included 19 healthy controls. Tagged images were acquired encompassing both the liver and the heart. The corresponding displacement and strains were calculated using a Gabor filter bank. The maximum displacement (MaxDisp) was found over the cardiac cycle, as well as the local maximum P1 (MaxP1) and minimum P2 strains (MinP2). Group comparisons were made without and with adjustment for age and gender. RESULTS: In control, LCA, and LCBC groups, the MaxDisp was 3.98 ± 0.88 mm, 2.52 ± 0.73 mm, and 1.86 ± 0.77 mm; the MaxP1 was 0.10 ± 0.02, 0.04 ± 0.01, and 0.02 ± 0.01; and the MinP2 was -0.08 ± 0.01, -0.05 ± 0.02, and -0.03 ± 0.01, respectively. Statistically significant differences were found between groups (P < 0.05 for all). CONCLUSION: This method measures cardiac-induced liver motion and deformation to assess liver stiffness. Significant differences were found in our stiffness measures between control, LCA, and LCBC groups, with more severe disease being associated with greater stiffness.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Coração/fisiopatologia , Interpretação de Imagem Assistida por Computador/métodos , Cirrose Hepática/diagnóstico , Cirrose Hepática/fisiopatologia , Fígado/patologia , Fígado/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Módulo de Elasticidade , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Contração Miocárdica/fisiologia , Miocárdio/patologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Coloração e Rotulagem , Adulto Jovem
15.
J Cardiovasc Magn Reson ; 16: 89, 2014 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-25388937

RESUMO

This article is an invited editorial comment on the paper entitled "In vivo cardiovascular magnetic resonance diffusion tensor imaging shows evidence of abnormal myocardial laminar orientations and mobility in hypertrophic cardiomyopathy" by Ferreira et al., and published as Journal of Cardiovascular Magnetic Resonance 2014; 16:87.


Assuntos
Cardiomiopatia Hipertrófica/diagnóstico , Imagem de Difusão por Ressonância Magnética , Imagem de Tensor de Difusão , Imagem Cinética por Ressonância Magnética , Contração Miocárdica , Miocárdio/patologia , Função Ventricular Esquerda , Feminino , Humanos , Masculino
16.
J Cardiovasc Magn Reson ; 16: 71, 2014 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-25242199

RESUMO

BACKGROUND: Measurement of mitral annulus (MA) dynamics is an important component of the evaluation of left ventricular (LV) diastolic function; MA velocities are commonly measured using tissue Doppler imaging (TDI). This study aimed to examine the clinical potential of a semi-automated cardiovascular magnetic resonance (CMR) technique for quantifying global LV diastolic function, using 3D volume tracking of the MA with conventional cine-CMR images. METHODS: 124 consecutive patients with normal ejection fraction underwent both clinically indicated transthoracic echocardiography (TTE) and CMR within 2 months. Interpolated 3D reconstruction of the MA over time was performed with semi-automated atrioventricular junction (AVJ) tracking in long-axis cine-CMR images, producing an MA sweep volume over the cardiac cycle. CMR-based diastolic function was evaluated, using the following parameters: peak volume sweep rates in early diastole (PSRE) and atrial systole (PSRA), PSRE/PSRA ratio, deceleration time of sweep volume (DTSV), and 50% diastolic sweep volume recovery time (DSVRT50); these were compared with TTE diastolic measurements. RESULTS: Patients with TTE-based diastolic dysfunction (n = 62) showed significantly different normalized MA sweep volume profiles compared to those with TTE-based normal diastolic function (n = 62), including a lower PSRE (5.25 ± 1.38 s-1 vs. 7.72 ± 1.7 s-1), a higher PSRA (6.56 ± 1.99 s-1 vs. 4.67 ± 1.38 s-1), a lower PSRE/PSRA ratio (0.9 ± 0.44 vs. 1.82 ± 0.69), a longer DTSV (144 ± 55 ms vs. 96 ± 37 ms), and a longer DSVRT50 (25.0 ± 11.0% vs. 15.6 ± 4.0%) (all p < 0.05). CMR diastolic parameters were independent predictors of TTE-based diastolic dysfunction after adjusting for left ventricular hypertrophy, hypertension, and coronary artery disease. Good correlations were observed between CMR PSRE/PSRA and early-to-late diastolic annular velocity ratios (e'/a') measured by TDI (r = 0.756 to 0.828, p < 0.001). CONCLUSIONS: 3D MA sweep volumes generated by semi-automated AVJ tracking in routinely acquired CMR images yielded diastolic parameters that were effective in identifying patients with diastolic dysfunction when correlated with TTE-based variables.


Assuntos
Diástole , Ecocardiografia Doppler de Pulso , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imagem Cinética por Ressonância Magnética/métodos , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Disfunção Ventricular Esquerda/diagnóstico , Função Ventricular Esquerda , Adulto , Idoso , Automação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia
17.
J Cardiovasc Magn Reson ; 16: 35, 2014 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-24886666

RESUMO

BACKGROUND: We have developed a novel and practical cardiovascular magnetic resonance (CMR) technique to evaluate left ventricular (LV) mitral annular motion by tracking the atrioventricular junction (AVJ). To test AVJ motion analysis as a metric for LV function, we compared AVJ motion variables between patients with hypertrophic cardiomyopathy (HCM), a group with recognized systolic and diastolic dysfunction, and healthy volunteers. METHODS: We retrospectively evaluated 24 HCM patients with normal ejection fractions (EF) and 14 healthy volunteers. Using the 4-chamber view cine images, we tracked the longitudinal motion of the lateral and septal AVJ at 25 time points during the cardiac cycle. Based on AVJ displacement versus time, we calculated maximum AVJ displacement (MD) and velocity in early diastole (MVED), velocity in diastasis (VDS) and the composite index VDS/MVED. RESULTS: Patients with HCM showed significantly slower median lateral and septal AVJ recoil velocities during early diastole, but faster velocities in diastasis. We observed a 16-fold difference in VDS/MVED at the lateral AVJ [median 0.141, interquartile range (IQR) 0.073, 0.166 versus 0.009 IQR -0.006, 0.037, P < 0.001]. Patients with HCM also demonstrated significantly less mitral annular excursion at both the septal and lateral AVJ. Performed offline, AVJ motion analysis took approximately 10 minutes per subject. CONCLUSIONS: Atrioventricular junction motion analysis provides a practical and novel CMR method to assess mitral annular motion. In this proof of concept study we found highly statistically significant differences in mitral annular excursion and recoil between HCM patients and healthy volunteers.


Assuntos
Cardiomiopatia Hipertrófica/diagnóstico , Imagem Cinética por Ressonância Magnética , Valva Mitral/fisiopatologia , Miocárdio/patologia , Disfunção Ventricular Esquerda/diagnóstico , Função Ventricular Esquerda , Adulto , Cardiomiopatia Hipertrófica/patologia , Cardiomiopatia Hipertrófica/fisiopatologia , Meios de Contraste , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Disfunção Ventricular Esquerda/patologia , Disfunção Ventricular Esquerda/fisiopatologia
18.
Int J Cardiovasc Imaging ; 40(1): 167-176, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37891449

RESUMO

While there have been many descriptions of characteristic motion findings in left bundle branch block (LBBB), there are few published descriptions of such findings in right bundle branch block (RBBB). The purpose of this study was to assess the frequency of particular regional motion findings in cardiac magnetic resonance imaging (CMR) studies of patients with RBBB, compared with normal subjects. We focused on three distinctive motion patterns that can be seen in RBBB during early systole: delayed apex-ward motion of the RV base, "reverse septal flash", and "basal bulge". The presence and relative magnitude of these findings were independently scored by four experienced observers, in 3-chamber and 4-chamber CMR cines, for both normal subjects and patients with RBBB. These motion patterns were found to be strongly associated with the presence of RBBB. While only moderately sensitive, they were quite specific for RBBB, when present. In particular, with ROC analysis, a combined feature set of the findings in the 4-chamber view had an area under the curve of 0.81.This previously undescribed set of RBBB-associated early-systolic regional motion features (delayed apex-ward motion of the RV base, "reverse septal flash", and "basal bulge") is strongly suggestive of RBBB when present, particularly in the 4-chamber view. Although here evaluated with CMR, it is also likely to be associated with RBBB when seen with other cardiac imaging modalities.


Assuntos
Bloqueio de Ramo , Imageamento por Ressonância Magnética , Humanos , Bloqueio de Ramo/diagnóstico por imagem , Bloqueio de Ramo/complicações , Valor Preditivo dos Testes , Coração , Ventrículos do Coração , Eletrocardiografia
19.
Magn Reson Med ; 70(5): 1274-82, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23280998

RESUMO

PURPOSE: To develop an arrhythmia-insensitive rapid (AIR) cardiac T1 mapping pulse sequence for quantification of diffuse fibrosis. METHODS: An arrhythmia-insensitive cardiac T1 mapping pulse sequence was developed based on saturation recovery T1 weighting, which is inherently insensitive to heart rate and rhythm, and two single-shot balanced steady-state free precession image acquisitions with centric k-space ordering, where T1 calculation is inherently insensitive to T2 effects. Its performance against conventional cardiac T1 mapping based on inversion recovery (i.e., MOLLI) is compared. Phantom experiments (T1 ranging from 535 to 2123 ms) were performed with heart rate and rhythm simulated at 60 and 120 beats per minute (bpm) and arrhythmia using an external triggering device. Ten human subjects and 17 large animals were scanned precontrast and 5, 10, and 15 min after contrast agent administration. RESULTS: Compared with the reference T1 mapping, AIR yielded lower normalized root-mean-square error than MOLLI (8% vs. 3%, respectively, at 60 bpm, 28% vs. 3%, respectively, at 120 bpm, and 22% vs. 3%, respectively, at arrhythmia). In vivo studies showed that T1 measurements made by MOLLI and AIR were strongly correlated (r = 0.99) but in poor agreement (mean difference = 161.8 ms, upper and lower 95% limits of agreements = 347.5 ms and -24.0 ms). CONCLUSION: Our AIR pulse sequence may be clinically useful for assessment of diffuse myocardial fibrosis in patients.


Assuntos
Arritmias Cardíacas/patologia , Técnicas de Imagem de Sincronização Cardíaca/métodos , Cardiomiopatias/patologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Miocárdio/patologia , Adulto , Algoritmos , Animais , Arritmias Cardíacas/complicações , Cardiomiopatias/complicações , Cães , Feminino , Fibrose , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
J Magn Reson Imaging ; 38(1): 180-8, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23197471

RESUMO

PURPOSE: To evaluate the feasibility and perform initial comparative evaluations of a 5-minute comprehensive whole-heart magnetic resonance imaging (MRI) protocol with four image acquisition types: perfusion (PERF), function (CINE), coronary artery imaging (CAI), and late gadolinium enhancement (LGE). MATERIALS AND METHODS: This study protocol was Health Insurance Portability and Accountability Act (HIPAA)-compliant and Institutional Review Board-approved. A 5-minute comprehensive whole-heart MRI examination protocol (Accelerated) using 6-8-fold-accelerated volumetric parallel imaging was incorporated into and compared with a standard 2D clinical routine protocol (Standard). Following informed consent, 20 patients were imaged with both protocols. Datasets were reviewed for image quality using a 5-point Likert scale (0 = non-diagnostic, 4 = excellent) in blinded fashion by two readers. RESULTS: Good image quality with full whole-heart coverage was achieved using the accelerated protocol, particularly for CAI, although significant degradations in quality, as compared with traditional lengthy examinations, were observed for the other image types. Mean total scan time was significantly lower for the Accelerated as compared to Standard protocols (28.99 ± 4.59 min vs. 1.82 ± 0.05 min, P < 0.05). Overall image quality for the Standard vs. Accelerated protocol was 3.67 ± 0.29 vs. 1.5 ± 0.51 (P < 0.005) for PERF, 3.48 ± 0.64 vs. 2.6 ± 0.68 (P < 0.005) for CINE, 2.35 ± 1.01 vs. 2.48 ± 0.68 (P = 0.75) for CAI, and 3.67 ± 0.42 vs. 2.67 ± 0.84 (P < 0.005) for LGE. Diagnostic image quality for Standard vs. Accelerated protocols was 20/20 (100%) vs. 10/20 (50%) for PERF, 20/20 (100%) vs. 18/20 (90%) for CINE, 18/20 (90%) vs. 18/20 (90%) for CAI, and 20/20 (100%) vs. 18/20 (90%) for LGE. CONCLUSION: This study demonstrates the technical feasibility and promising image quality of 5-minute comprehensive whole-heart cardiac examinations, with simplified scan prescription and high spatial and temporal resolution enabled by highly parallel imaging technology. The study also highlights technical hurdles that remain to be addressed. Although image quality remained diagnostic for most scan types, the reduced image quality of PERF, CINE, and LGE scans in the Accelerated protocol remain a concern.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/instrumentação , Imageamento Tridimensional/instrumentação , Imagem Cinética por Ressonância Magnética/instrumentação , Magnetismo/instrumentação , Isquemia Miocárdica/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Aumento da Imagem/instrumentação , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA