Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Vasc Surg ; 79(6): 1390-1400.e8, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38325564

RESUMO

OBJECTIVE: This study aims to evaluate a fully automatic deep learning-based method (augmented radiology for vascular aneurysm [ARVA]) for aortic segmentation and simultaneous diameter and volume measurements. METHODS: A clinical validation dataset was constructed from preoperative and postoperative aortic computed tomography angiography (CTA) scans for assessing these functions. The dataset totaled 350 computed tomography angiography scans from 216 patients treated at two different hospitals. ARVA's ability to segment the aorta into seven morphologically based aortic segments and measure maximum outer-to-outer wall transverse diameters and compute volumes for each was compared with the measurements of six experts (ground truth) and thirteen clinicians. RESULTS: Ground truth (experts') measurements of diameters and volumes were manually performed for all aortic segments. The median absolute diameter difference between ground truth and ARVA was 1.6 mm (95% confidence interval [CI], 1.5-1.7; and 1.6 mm [95% CI, 1.6-1.7]) between ground truth and clinicians. ARVA produced measurements within the clinical acceptable range with a proportion of 85.5% (95% CI, 83.5-86.3) compared with the clinicians' 86.0% (95% CI, 83.9-86.0). The median volume similarity error ranged from 0.93 to 0.95 in the main trunk and achieved 0.88 in the iliac arteries. CONCLUSIONS: This study demonstrates the reliability of a fully automated artificial intelligence-driven solution capable of quick aortic segmentation and analysis of both diameter and volume for each segment.


Assuntos
Aortografia , Angiografia por Tomografia Computadorizada , Aprendizado Profundo , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Humanos , Reprodutibilidade dos Testes , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Automação , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Conjuntos de Dados como Assunto , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia
2.
J Cardiovasc Magn Reson ; 24(1): 59, 2022 11 14.
Artigo em Inglês | MEDLINE | ID: mdl-36372884

RESUMO

BACKGROUND: Four-dimensional flow cardiovascular magnetic resonance imaging (4D flow CMR) allows comprehensive assessment of pulmonary artery (PA) flow dynamics. Few studies have characterized longitudinal changes in pulmonary flow dynamics and right ventricular (RV) recovery following a pulmonary endarterectomy (PEA) for patients with chronic thromboembolic pulmonary hypertension (CTEPH). This can provide novel insights of RV and PA dynamics during recovery. We investigated the longitudinal trajectory of 4D flow metrics following a PEA including velocity, vorticity, helicity, and PA vessel wall stiffness. METHODS: Twenty patients with CTEPH underwent pre-PEA and > 6 months post-PEA CMR imaging including 4D flow CMR; right heart catheter measurements were performed in 18 of these patients. We developed a semi-automated pipeline to extract integrated 4D flow-derived main, left, and right PA (MPA, LPA, RPA) volumes, velocity flow profiles, and secondary flow profiles. We focused on secondary flow metrics of vorticity, volume fraction of positive helicity (clockwise rotation), and the helical flow index (HFI) that measures helicity intensity. RESULTS: Mean PA pressures (mPAP), total pulmonary resistance (TPR), and normalized RV end-systolic volume (RVESV) decreased significantly post-PEA (P < 0.002). 4D flow-derived PA volumes decreased (P < 0.001) and stiffness, velocity, and vorticity increased (P < 0.01) post-PEA. Longitudinal improvements from pre- to post-PEA in mPAP were associated with longitudinal decreases in MPA area (r = 0.68, P = 0.002). Longitudinal improvements in TPR were associated with longitudinal increases in the maximum RPA HFI (r=-0.85, P < 0.001). Longitudinal improvements in RVESV were associated with longitudinal decreases in MPA fraction of positive helicity (r = 0.75, P = 0.003) and minimum MPA HFI (r=-0.72, P = 0.005). CONCLUSION: We developed a semi-automated pipeline for analyzing 4D flow metrics of vessel stiffness and flow profiles. PEA was associated with changes in 4D flow metrics of PA flow profiles and vessel stiffness. Longitudinal analysis revealed that PA helicity was associated with pulmonary remodeling and RV reverse remodeling following a PEA.


Assuntos
Hipertensão Pulmonar , Embolia Pulmonar , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/cirurgia , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/cirurgia , Valor Preditivo dos Testes , Endarterectomia/métodos , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Imageamento por Ressonância Magnética , Remodelação Ventricular , Espectroscopia de Ressonância Magnética , Função Ventricular Direita
3.
Eur J Vasc Endovasc Surg ; 62(6): 869-877, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34518071

RESUMO

OBJECTIVE: The aim of this study was to evaluate an automatic, deep learning based method (Augmented Radiology for Vascular Aneurysm [ARVA]), to detect and assess maximum aortic diameter, providing cross sectional outer to outer aortic wall measurements. METHODS: Accurate external aortic wall diameter measurement is performed along the entire aorta, from the ascending aorta to the iliac bifurcations, on both pre- and post-operative contrast enhanced computed tomography angiography (CTA) scans. A training database of 489 CTAs was used to train a pipeline of neural networks for automatic external aortic wall measurements. Another database of 62 CTAs, including controls, aneurysmal aortas, and aortic dissections scanned before and/or after endovascular or open repair, was used for validation. The measurements of maximum external aortic wall diameter made by ARVA were compared with those of seven clinicians on this validation dataset. RESULTS: The median absolute difference with respect to expert's measurements ranged from 1 mm to 2 mm among all annotators, while ARVA reported a median absolute difference of 1.2 mm. CONCLUSION: The performance of the automatic maximum aortic diameter method falls within the interannotator variability, making it a potentially reliable solution for assisting clinical practice.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aortografia , Angiografia por Tomografia Computadorizada , Redes Neurais de Computação , Interpretação de Imagem Radiográfica Assistida por Computador , Adulto , Idoso , Idoso de 80 Anos ou mais , Automação , Bases de Dados Factuais , Aprendizado Profundo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
4.
J Cardiovasc Magn Reson ; 23(1): 140, 2021 12 30.
Artigo em Inglês | MEDLINE | ID: mdl-34969397

RESUMO

BACKGROUND: Recent evidence shows an association between coronavirus disease 2019 (COVID-19) infection and a severe inflammatory syndrome in children. Cardiovascular magnetic resonance (CMR) data about myocardial injury in children are limited to small cohorts. The aim of this multicenter, international registry is to describe clinical and cardiac characteristics of multisystem inflammatory syndrome in children (MIS-C) associated with COVID-19 using CMR so as to better understand the real extent of myocardial damage in this vulnerable cohort. METHODS AND RESULTS: Hundred-eleven patients meeting the World Health Organization criteria for MIS-C associated with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), having clinical cardiac involvement and having received CMR imaging scan were included from 17 centers. Median age at disease onset was 10.0 years (IQR 7.0-13.8). The majority of children had COVID-19 serology positive (98%) with 27% of children still having both, positive serology and polymerase chain reaction (PCR). CMR was performed at a median of 28 days (19-47) after onset of symptoms. Twenty out of 111 (18%) patients had CMR criteria for acute myocarditis (as defined by the Lake Louise Criteria) with 18/20 showing subepicardial late gadolinium enhancement (LGE). CMR myocarditis was significantly associated with New York Heart Association class IV (p = 0.005, OR 6.56 (95%-CI 1.87-23.00)) and the need for mechanical support (p = 0.039, OR 4.98 (95%-CI 1.18-21.02)). At discharge, 11/111 (10%) patients still had left ventricular systolic dysfunction. CONCLUSION: No CMR evidence of myocardial damage was found in most of our MIS-C cohort. Nevertheless, acute myocarditis is a possible manifestation of MIS-C associated with SARS-CoV-2 with CMR evidence of myocardial necrosis in 18% of our cohort. CMR may be an important diagnostic tool to identify a subset of patients at risk for cardiac sequelae and more prone to myocardial damage. CLINICAL TRIAL REGISTRATION: The study has been registered on ClinicalTrials.gov, Identifier NCT04455347, registered on 01/07/2020, retrospectively registered.


Assuntos
COVID-19 , Miocardite , COVID-19/complicações , Criança , Meios de Contraste , Gadolínio , Humanos , Espectroscopia de Ressonância Magnética , Miocardite/diagnóstico por imagem , Miocardite/epidemiologia , Valor Preditivo dos Testes , Sistema de Registros , SARS-CoV-2 , Síndrome de Resposta Inflamatória Sistêmica
8.
Radiographics ; 39(3): 632-648, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30901284

RESUMO

In-plane phase-contrast (PC) imaging is now a routine component of MRI of regional blood flow in the heart and great vessels. In-plane PC MRI provides a volumetric, isotropic, time-resolved cine sequence that enables three-directional velocity encoding, a technique known as four-dimensional (4D) flow MRI. Recent advances in 4D flow MRI have shortened imaging times, while progress in big-data processing has improved dataset pre- and postprocessing, thereby increasing the feasibility of 4D flow MRI in clinical practice. Important technical issues include selection of the optimal velocity-encoding sensitivity before acquisition and preprocessing of the raw data for phase-offset corrections. Four-dimensional flow MRI provides unprecedented capabilities for comprehensive analysis of complex blood flow patterns using new visualization tools such as streamlines and velocity vectors. Retrospective multiplanar navigation enables flexible retrospective flow quantification through any plane across the volume with good accuracy. Current flow parameters include forward flow, reverse flow, regurgitation fraction, and peak velocity. Four-dimensional flow MRI also supplies advanced flow parameters of use for research, such as wall shear stress. The vigorous burgeoning of new applications indicates that 4D flow MRI is becoming an important imaging modality for cardiovascular disorders. This article reviews the main technical issues of 4D flow MRI and the different parameters provided by it and describes the main applications in cardiovascular diseases, including congenital heart disease, cardiac valvular disease, aortic disease, and pulmonary hypertension. Online supplemental material is available for this article. ©RSNA, 2019 See discussion on this article by Ordovas .


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Artefatos , Big Data , Velocidade do Fluxo Sanguíneo , Meios de Contraste , Processamento Eletrônico de Dados/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Angiografia por Ressonância Magnética/métodos , Movimento (Física) , Resistência ao Cisalhamento , Software
9.
Eur J Haematol ; 94(4): 363-7, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24797802

RESUMO

The second-generation tyrosine kinase inhibitor (TKI) of the BCR-ABL1 oncoprotein nilotinib used in patients with chronic myeloid leukemia is suspected to increase the risk of arterial occlusion, especially in patients with pre-existing cardiovascular risk factors or established cardiovascular diseases. Here, we describe a case of unexpected and rapid onset of symptomatic peripheral artery disease (PAD) associated with silent stenosis of digestive and renal arteries in a nilotinib-treated patient devoid of significant cardiovascular diseases (CVD) risk factor, prior atherosclerotic disease, or other cause of arterial damage. This is the first report to establish a direct relationship between nilotinib exposure and PAD and to reveal that arterial damage is irreversible despite rapid drug withdrawal. However, functional outcome was favorable upon rapid TKI replacement, specific cardiovascular disease management, and development of collateral arterial network.


Assuntos
Antineoplásicos/efeitos adversos , Leucemia Mielogênica Crônica BCR-ABL Positiva/complicações , Doença Arterial Periférica/etiologia , Inibidores de Proteínas Quinases/efeitos adversos , Pirimidinas/efeitos adversos , Angiografia , Antineoplásicos/uso terapêutico , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Substituição de Medicamentos , Proteínas de Fusão bcr-abl/antagonistas & inibidores , Proteínas de Fusão bcr-abl/genética , Humanos , Leucemia Mielogênica Crônica BCR-ABL Positiva/tratamento farmacológico , Leucemia Mielogênica Crônica BCR-ABL Positiva/genética , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados da Assistência ao Paciente , Doença Arterial Periférica/diagnóstico , Inibidores de Proteínas Quinases/uso terapêutico , Pirimidinas/uso terapêutico , Resultado do Tratamento
10.
Eur Radiol ; 25(4): 1077-86, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25430004

RESUMO

OBJECTIVES: Our objectives were to assess the ability of phasecontrast MRI (PC-MRI) to detect sub-clinical age-related variations of left ventricular (LV) diastolic parameters and thus to provide age-related reference ranges currently available for echocardiography but not for MRI-PC, and to identify independent associates of such variations. METHODS: We studied 100 healthy volunteers (age = 42 ± 15years, 50 females) who had MRI with simultaneous blood pressure measurements. LV mass and volumes were assessed. Semiautomated analysis of PC-MRI data provided: 1) early transmitral (Ef) and atrial (Af) peak filling flow-rates (ml/s) and filling volume (FV), 2) deceleration time (DT), isovolumic relaxation time (IVRT), and 3) early myocardial longitudinal (E') peak velocity. RESULTS: MRI-PC diastolic parameters were reproducible as reflected by low coefficients of variations (ranged between 0.31 to 6.26 %). Peak myocardial velocity E' (r = -0.63, p < 0.0001) and flow-rate parameters were strongly and independently associated to age (Ef/Af:r = -0.63, DT:r = 0.46, IVRT:r = 0.44, Ef/FV:r = -0.55, Af/FV:r = 0.56, p < 0.0001). Furthermore, LV relaxation parameters (E', DT, IVRT), were independently associated to LV remodelling (LV mass/end-diastolic volume) and myocardial wall thickness (p < 0.01). CONCLUSIONS: PC-MRI age-related reference ranges of diastolic parameters are provided. Such parameters might be useful for a fast, reproducible and reliable characterization of diastolic function in patients referred for clinical MRI exam KEY POINTS: • MRI age-related reference values of left ventricular diastolic parameters are provided. • MRI diastolic parameters can characterise sub-clinical age-related variations in healthy individuals. • Diastolic function would complement cardiac MRI exam with currently neglected data. • Diastolic function would enhance MRI diagnostic value in cardiomyopathy and heartfailure.


Assuntos
Envelhecimento/fisiologia , Ventrículos do Coração/anatomia & histologia , Imagem Cinética por Ressonância Magnética/métodos , Função Ventricular Esquerda/fisiologia , Adulto , Fatores Etários , Diástole , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
11.
Diagn Interv Imaging ; 105(7-8): 266-272, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38368175

RESUMO

PURPOSE: The purpose of this study was to evaluate the accuracy of four-dimensional flow cardiac magnetic resonance imaging (4D flow MRI) compared to right heart catheterization in measuring pulmonary flow (Qp), systemic flow (Qs) and pulmonary-to-systemic flow ratio (Qp/Qs) in patients with pulmonary arterial hypertension associated with congenital heart disease (PAH-CHD). MATERIALS AND METHODS: The study was registered on Clinical-trial.gov (NCT03928002). Sixty-four patients with PAH-CHD who underwent 4D flow MRI were included. There were 16 men and 48 women with a mean age of 45.3 ± 13.7 (standard deviation [SD]) years (age range: 21-77 years). Fifty patients (50/64; 78%) presented with pre-tricuspid shunt. Qp (L/min), Qs (L/min) and Qp/Qs were measured invasively using direct Fick method during right heart catheterization and compared with measurements assessed by 4D flow MRI within a 24-48-hour window. RESULTS: The average mean pulmonary artery pressure was 51 ± 17 (SD) mm Hg with median pulmonary vascular resistance of 8.8 Wood units (Q1, Q3: 5.3, 11.7). A strong linear correlation was found between Qp measurements obtained with 4D flow MRI and those obtained with the Fick method (r = 0.96; P < 0.001). Bland Altman analysis indicated a mean difference of 0.15 ± 0.48 (SD) L/min between Qp estimated by 4D flow MRI and by right heart catheterization. A strong correlation was found between Qs and Qp/Qs measured by 4D flow MRI and those obtained with the direct Fick method (r = 0.85 and r = 0.92; P < 0.001 for both). CONCLUSION: Qp as measured by 4D flow MRI shows a strong correlation with measurements derived from the direct Fick method. Further investigation is needed to develop less complex and standardized methods for measuring essential PAH parameters, such as pulmonary arterial pressures and pulmonary vascular resistance.


Assuntos
Cateterismo Cardíaco , Cardiopatias Congênitas , Imageamento por Ressonância Magnética , Circulação Pulmonar , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/fisiopatologia , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Hipertensão Arterial Pulmonar/diagnóstico por imagem , Hipertensão Arterial Pulmonar/fisiopatologia , Circulação Pulmonar/fisiologia , Estudos Prospectivos
12.
Circulation ; 126(25): 3062-9, 2012 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-23155180

RESUMO

BACKGROUND: Initially based on histology, the diagnosis of renal artery fibromuscular dysplasia (FMD) is now based mostly on angiographic appearance because arterial tissue samples are rarely available. This retrospective cross-sectional study aimed to assess the clinical relevance of a binary angiographic classification of FMD lesions (unifocal or multifocal) based on computed tomographic or magnetic resonance angiography. METHODS AND RESULTS: Adult patients diagnosed with FMD in a single tertiary care center for hypertension management were identified by screening of electronic files. FMD lesions were reviewed and classified according to computed tomography or magnetic resonance angiography as multifocal if there were at least 2 stenoses in the same arterial segment; otherwise, they were classified as unifocal. Of 337 patients with established renal artery FMD, 276 (82%) were classified as multifocal. Patients with unifocal and multifocal lesions differed significantly in median age at diagnosis of FMD (30 and 49 years) and hypertension (26 and 40 years), sex distribution (female:male ratio, 2:1 and 5:1), initial blood pressure (157/97 and 146/88 mm Hg), current smoking (50% and 26%), prevalence of unilateral renal artery lesions (79% and 38%), presence of kidney asymmetry (33% and 10%), renal revascularization procedures (90% and 35%), and hypertension cure rates in patients who underwent revascularization (54% and 26%). CONCLUSIONS: A binary angiographic classification into unifocal or multifocal renal artery FMD is straightforward and discriminates 2 groups of patients with different clinical phenotypes.


Assuntos
Displasia Fibromuscular/diagnóstico por imagem , Adulto , Estudos Transversais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Artéria Renal/diagnóstico por imagem , Estudos Retrospectivos
13.
Rev Esp Cardiol (Engl Ed) ; 76(1): 10-18, 2023 Jan.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35570123

RESUMO

INTRODUCTION AND OBJECTIVES: Diagnosis, management, and surgical decision-making in children and adults with congenital heart disease are largely based on echocardiography findings. A recent development in cardiac imaging is fusion of different imaging modalities. Our objective was to evaluate the feasibility of computed tomography (CT) and 3-dimensional (3D) transthoracic echocardiography (TTE) fusion in children and adults with congenital heart disease. METHODS: We prospectively included 14 patients, 13 of whom had congenital heart disease, and who underwent both CT and 3D TTE as part of their usual follow-up. We described the steps required to complete the fusion process (alignment, landmarks, and superimposition), navigation, and image evaluation. RESULTS: Median age was 9.5 [2.7-15.7] years, 57% were male, and median body surface area was 0.9 m2 [0.6-1.7]. Congenital heart disease was classified as simple (n=4, 29%), moderate (n=4, 29%), or complex (n=6, 42%). 3D TTE-CT fusion was successful in all patients. Median total time to complete the fusion process was 735 [628-1163] seconds, with no significant difference according to the degree of complexity of the defects. Landmarks were significantly modified in complex congenital heart disease. CONCLUSIONS: We established the feasibility and accuracy of 3D TTE-CT fusion in a population of children and adults with a variety of congenital heart diseases. The simultaneous visualization of many intracardiac structures may help to understand the anatomical features of congenital heart disease without limitations regarding age, weight, or complexity of the congenital defects.


Assuntos
Ecocardiografia Tridimensional , Cardiopatias Congênitas , Criança , Adulto , Humanos , Masculino , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Ecocardiografia/métodos , Coração/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Tomografia Computadorizada por Raios X
14.
Rev Esp Cardiol (Engl Ed) ; 76(5): 333-343, 2023 May.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35940550

RESUMO

INTRODUCTION AND OBJECTIVES: Outcome in patients with congenital heart diseases and pulmonary arterial hypertension (PAH) is closely related to right ventricular (RV) function. Two-dimensional echocardiographic parameters, such as strain imaging or RV end-systolic remodeling index (RVESRI) have emerged to quantify RV function. METHODS: We prospectively studied 30 patients aged 48±12 years with pretricuspid shunt and PAH and investigated the accuracy of multiple echocardiographic parameters of RV function (tricuspid annular plane systolic excursion, tricuspid annular peak systolic velocity, RV systolic-to-diastolic duration ratio, right atrial area, RV fractional area change, RV global longitudinal strain and RVESRI) to RV ejection fraction measured by cardiac magnetic resonance. RESULTS: RV ejection fraction <45% was observed in 13 patients (43.3%). RV global longitudinal strain (ρ [Spearman's correlation coefficient]=-0.75; P=.001; R2=0.58; P=.001), right atrium area (ρ=-0.74; P <.0001; R2=0.56; P <.0001), RVESRI (ρ=-0.64; P <.0001; R2=0.47; P <.0001), systolic-to-diastolic duration ratio (ρ=-0.62; P=.0004; R2=0.47; P <.0001) and RV fractional area change (ρ=0.48; P=.01; R2=0.37; P <.0001) were correlated with RV ejection fraction. RV global longitudinal strain, RVESRI and right atrium area predicted RV ejection fraction <45% with the greatest area under curve (0.88; 95%CI, 0.71-1.00; 0.88; 95%CI, 0.76-1.00, and 0.89; 95%CI, 0.77-1.00, respectively). RV global longitudinal strain >-16%, RVESRI ≥ 1.7 and right atrial area ≥ 22 cm2 predicted RV ejection fraction <45% with a sensitivity and specificity of 87.5% and 85.7%; 76.9% and 88.3%; 92.3% and 82.4%, respectively. CONCLUSIONS: RVESRI, right atrial area and RV global longitudinal strain are strong markers of RV dysfunction in patients with pretricuspid shunt and PAH.


Assuntos
Fibrilação Atrial , Cardiopatias Congênitas , Hipertensão Pulmonar , Hipertensão Arterial Pulmonar , Disfunção Ventricular Direita , Humanos , Hipertensão Arterial Pulmonar/complicações , Função Ventricular Direita , Fibrilação Atrial/complicações , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/etiologia , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/diagnóstico , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/etiologia , Volume Sistólico
16.
Presse Med ; 51(2): 104119, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35321846

RESUMO

During the last 20 years, cardiac imaging has drastically evolved. Positron emission tomography (PET), fast three-dimensional (3D) imaging with the latest generations of echocardiography & multi-detector computed tomography (CT), stress perfusion assessed by magnetic resonance imaging (MRI), blood flow analysis using four-dimensional (4D) flow MRI, all these techniques offer new trends for optimal noninvasive functional cardiac imaging. Dynamic functional imaging is obtained by acquiring images of the heart at different phases of the cardiac cycle, allowing assessment of cardiac motion, function, and perfusion. Between CT and Cardiac MRI (CMR), CMR has the best temporal resolution, which is suitable for functional imaging while cardiac CT provides higher spatial resolution with isotropic data that have an identical resolution in the three dimensions of the space. The latest generations of CT scanners enable whole heart assessment in one beat, offering also an acceptable temporal resolution with the possibility to display the images in a dynamic mode. Another rapidly growing technique using functional and molecular imaging for the assessment of biological and metabolic pathways is the PET using radio-labeled tracers. Meanwhile, the oldest cardiac imaging tool with doppler ultrasound technology has never stopped evolving. Echocardiography today performs 3D imaging, stress perfusion, and myocardial strain assessment, with high temporal resolution. It still is the first line and more accessible exam for the patient. These different modalities are complementary and may be even combined into PET-CT or PET-MRI. The ability to combine the functional/molecular data with anatomical images may implement a new dimension to our diagnostic tools.


Assuntos
Coração , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Coração/diagnóstico por imagem
17.
JTO Clin Res Rep ; 3(12): 100432, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36471682

RESUMO

Antibody-drug conjugates targeting receptor tyrosine-protein kinase erbB-2 (ERBB2, HER2) have emerged as promising targeted options for HER2-mutant NSCLC. Among antibody-drug conjugates targeting HER2, trastuzumab deruxtecan was found to have the most impressive efficacy and is a potential new standard of care. Drug-related interstitial lung disease remains a serious unpredictable identified risk for patients treated with trastuzumab deruxtecan, requiring careful monitoring and multidisciplinary management. We report the first two cases of drug-related cardiotoxicity with acute myocarditis that developed after the first trastuzumab deruxtecan cycle. Routine cardiovascular risk screening is advisable, with close collaboration between cardiology specialists and oncologists.

19.
Eur Heart J Case Rep ; 5(5): ytab164, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34124566

RESUMO

BACKGROUND: Intracardiac masses are relatively rare but the diagnosis can be challenging for the cardiologist and the clinical presentation can be misleading. While most of the cardiac masses are benign, malignant masses are mostly metastatic tumours. CASE SUMMARY: An 81-year-old man was admitted to the cardiology department for congestive heart failure with the complaint of recent dyspnoea. The initial electrocardiogram was suggestive of a late presentation of an anterior myocardial infarction. Blood test showed mild and stable elevation of troponin and brain natriuretic peptide. Doppler-echocardiography revealed an interventricular septal thickening. Contrast echocardiography revealed a mass with a possibly necrotic centre and peripheral hypervascularization. Cardiac computed tomography (CT) confirmed the existence of a cardiac tumour with a hypodense centre and also revealed the presence of a large tumour of the lung's left lower lobe with multiple enlarged lymph nodes associated with possible left adrenal gland metastasis. Computed tomography-guided percutaneous biopsy of the pulmonary mass demonstrated a squamous cell lung cancer which was likely the primary cancer. The patient was discharged home waiting for chemotherapy to start but died a few days later at home of an unknown cause. DISCUSSION: Diagnosis of intracardiac mass is difficult, often requiring multiple imaging modalities. Contrast-enhanced echocardiography may help early diagnosis and can be easily implemented with other imaging modalities such as cardiac magnetic resonance imaging or CT.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA