1.
J Am Heart Assoc ; 8(21): e012594, 2019 11 05.
Artigo em Inglês | MEDLINE | ID: mdl-31640455

RESUMO

Background As transcatheter aortic valve replacement expands to younger and/or lower risk patients, the long-term consequences of permanent pacemaker implantation are a concern. Pacemaker dependency and impact have not been methodically assessed in transcatheter aortic valve replacement trials. We report the incidence and predictors of pacemaker implantation and pacemaker dependency after transcatheter aortic valve replacement with the Lotus valve. Methods and Results A total of 912 patients with high/extreme surgical risk and symptomatic aortic stenosis were randomized 2:1 (Lotus:CoreValve) in REPRISE III (The Repositionable Percutaneous Replacement of Stenotic Aortic Valve through Implantation of Lotus Valve System-Randomized Clinical Evaluation) trial. Systematic assessment of pacemaker dependency was pre-specified in the trial design. Pacemaker implantation within 30 days was more frequent with Lotus than CoreValve. By multivariable analysis, predictors of pacemaker implantation included baseline right bundle branch block and depth of implantation; diabetes mellitus was also a predictor with Lotus. No association between new pacemaker implantation and clinical outcomes was found. Pacemaker dependency was dynamic (30 days: 43%; 1 year: 50%) and not consistent for individual patients over time. Predictors of pacemaker dependency at 30 days included baseline right bundle branch block, female sex, and depth of implantation. No differences in mortality or stroke were found between patients who were pacemaker dependent or not at 30 days. Rehospitalization was higher in patients who were not pacemaker dependent versus patients without a pacemaker or those who were dependent. Conclusions Pacemaker implantation was not associated with adverse clinical outcomes. Most patients with a new pacemaker at 30 days were not dependent at 1 year. Mortality and stroke were similar between patients with or without pacemaker dependency and patients without a pacemaker. Clinical Trial Registration URL: https://www.clinicaltrials.gov/. Unique identifier NCT02202434.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bloqueio de Ramo/terapia , Marca-Passo Artificial , Complicações Pós-Operatórias/terapia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino
2.
JAMA Cardiol ; 4(3): 223-229, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30810703

RESUMO

Importance: To our knowledge, REPRISE III is the first large randomized comparison of 2 different transcatheter aortic valve replacement platforms: the mechanically expanded Lotus valve (Boston Scientific) and self-expanding CoreValve (Medtronic). Objective: To evaluate outcomes of Lotus vs CoreValve after 2 years. Design, Setting, and Participants: A total of 912 patients with high/extreme risk and severe, symptomatic aortic stenosis enrolled between September 22, 2014, and December 24, 2015, were randomized 2:1 to receive Lotus (607 [66.6%]) or CoreValve (305 [33.4%] at 55 centers in North America, Europe, and Australia. The first 2-year visit occurred on October 17, 2016, and the last was conducted on April 12, 2018. Clinical and echocardiographic assessments are complete through 2 years and will continue annually through 5 years. Main Outcomes and Measures: All-cause mortality and all-cause mortality or disabling stroke at 2 years. Other clinical factors included overall stroke, disabling stroke, repeated procedures, rehospitalization, valve thrombosis, and pacemaker implantation. Echocardiographic analyses included effective orifice area, mean gradient, and paravalvular leaks (PVLs). Results: Of 912 participants, the mean (SD) age was 82.8 (7.3) years, 465 (51%) were women, and the mean (SD) Society of Thoracic Surgeons predicted risk of mortality was 6.8% (4.0%). At 2 years, all-cause death was 21.3% with Lotus vs 22.5% with CoreValve (hazard ratio [HR], 0.94; 95% CI, 0.69-1.26; P = .67) and all-cause mortality or disabling stroke was 22.8% with Lotus and 27.0% with CoreValve (HR, 0.81; 95% CI, 0.61-1.07; P = .14). Overall stroke was 8.4% vs 11.4% (HR, 0.75; 95% CI, 0.48-1.17; P = .21); disabling stroke was more frequent with CoreValve vs Lotus (4.7% Lotus vs 8.6% CoreValve; HR, 0.53; 95% CI, 0.31-0.93; P = .02). More Lotus patients received a new permanent pacemaker (41.7% vs 26.1%; HR, 1.87; 95% CI, 1.41-2.49; P < .01) or had a valve thrombosis (3.0% vs 0.0%; P < .01) compared with CoreValve. More patients who received CoreValve experienced a repeated procedure (0.6% Lotus vs 2.9% CoreValve; HR, 0.19; 95% CI, 0.05-0.70; P < .01), valve migration (0.0% vs 0.7%; P = .05), or embolization (0.0% vs 2.0%; P < .01) than Lotus. Valve areas remained significantly larger and the mean gradient was lower with CoreValve than Lotus (valve area, mean [SD]: Lotus, 1.53 [0.49] cm2 vs CoreValve, 1.76 [0.51] cm2; P < .01; valve gradient, mean [SD]: Lotus, 13.0 [6.7] mm Hg vs 8.1 [3.7] mm Hg; P < .01). Moderate or greater PVL was more frequent with CoreValve (0.3% Lotus vs 3.8% CoreValve; P < .01) at 2 years. Larger improvements in New York Heart Association (NYHA) functional class were observed with Lotus compared with CoreValve (improved by ≥1 NYHA class: Lotus, 338 of 402 [84.1%] vs CoreValve, 143 of 189 [75.7%]; P = .01; improved by ≥2 NYHA classes: 122 of 402 [37.3%] vs 65 of 305 [21.3%]). Conclusions and Relevance: After 2 years, all-cause mortality rates, mortality or disabling stroke were similar between Lotus and CoreValve. Disabling stroke, functional class, valve migration, and PVL favored the Lotus arm whereas valve hemodynamics, thrombosis, and new pacemaker implantation favored the CoreValve arm. Trial Registration: clinicaltrials.gov Identifier: NCT02202434.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/patologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/patologia , Austrália/epidemiologia , Boston/epidemiologia , Ecocardiografia/métodos , Europa (Continente)/epidemiologia , Feminino , Próteses Valvulares Cardíacas/estatística & dados numéricos , Humanos , Masculino , Readmissão do Paciente/estatística & dados numéricos , Desenho de Prótese/tendências , Índice de Gravidade de Doença , Acidente Vascular Cerebral/etiologia , Trombose/etiologia , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento