Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 161
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 35(4): 625-638, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38174841

RESUMO

INTRODUCTION: The utility of ablation index (AI) to guide ventricular tachycardia (VT) ablation in patients with structural heart disease is unknown. The aim of this study was to assess procedural characteristics and clinical outcomes achieved using AI-guided strategy (target value 550) or conventional non-AI-guided parameters in patients undergoing scar-related VT ablation. METHODS: Consecutive patients (n = 103) undergoing initial VT ablation at a single center from 2017 to 2022 were evaluated. Patient groups were 1:1 propensity-matched for baseline characteristics. Single lesion characteristics for all 4707 lesions in the matched cohort (n = 74) were analyzed. The impact of ablation characteristics was assessed by linear regression and clinical outcomes were evaluated by Cox proportional hazard model. RESULTS: After propensity-matching, baseline characteristics were well-balanced between AI (n = 37) and non-AI (n = 37) groups. Lesion sets were similar (scar homogenization [41% vs. 27%; p = .34], scar dechanneling [19% vs. 8%; p = .18], core isolation [5% vs. 11%; p = .4], linear and elimination late potentials/local abnormal ventricular activities [35% vs. 44%; p = .48], epicardial mapping/ablation [11% vs. 14%; p = .73]). AI-guided strategy had 21% lower procedure duration (-47.27 min, 95% confidence interval [CI] [-81.613, -12.928]; p = .008), 49% lower radiofrequency time per lesion (-13.707 s, 95% CI [-17.86, -9.555]; p < .001), 21% lower volume of fluid administered (1664 cc [1127, 2209] vs. 2126 cc [1750, 2593]; p = .005). Total radiofrequency duration (-339 s [-24%], 95%CI [-776, 62]; p = .09) and steam pops (-155.6%, 95% CI [19.8%, -330.9%]; p = .08) were nonsignificantly lower in the AI group. Acute procedural success (95% vs. 89%; p = .7) and VT recurrence (0.97, 95% CI [0.42-2.2]; p = .93) were similar for both groups. Lesion analysis (n = 4707) demonstrated a plateau in the magnitude of impedance drops once reaching an AI of 550-600. CONCLUSION: In this pilot study, an AI-guided ablation strategy for scar-related VT resulted in shorter procedure time and average radiofrequency time per lesion with similar acute procedural and intermediate-term clinical outcomes to a non-AI-guided approach utilizing traditional ablation parameters.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Projetos Piloto , Cicatriz/diagnóstico , Cicatriz/etiologia , Cicatriz/cirurgia , Resultado do Tratamento , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
2.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38363995

RESUMO

Ventricular tachycardia (VT), and its occurrence, is still one of the main reasons for sudden cardiac death and, therefore, for increased mortality and morbidity foremost in patients with structural heart [Kahle A-K, Jungen C, Alken F-A, Scherschel K, Willems S, Pürerfellner H et al. Management of ventricular tachycardia in patients with ischaemic cardiomyopathy: contemporary armamentarium. Europace 2022;24:538-51]. Catheter ablation has become a safe and effective treatment option in patients with recurrent VT [Cronin EM, Bogun FM, Maury P, Peichl P, Chen M, Namboodiri N et al. 2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias. Heart Rhythm 2020;17:e2-154]. Previous and current guidelines provide guidance on indication for VT ablation and risk assessment and evaluation of underlying disease. However, no uniform recommendation is provided regarding procedural strategies, timing of ablation, and centre setting. Therefore, these specifics seem to differ largely, and recent data are sparse. This physician-based European Heart Rhythm Association survey aims to deliver insights on not only infrastructural settings but also procedural specifics, applied technologies, ablation strategies, and procedural endpoints. Therefore, these findings might deliver a real-world scenario of VT management and potentially are of guidance for other centres.


Assuntos
Ablação por Cateter , Isquemia Miocárdica , Taquicardia Ventricular , Humanos , Fluxo de Trabalho , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas/cirurgia , Resultado do Tratamento , Ablação por Cateter/métodos
3.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38607938

RESUMO

AIMS: Atrial fibrillation (AF) recurs in about one-third of patients after catheter ablation (CA), mostly in the first year. Little is known about the electrophysiological findings and the effect of re-ablation in very late AF recurrences (VLR) after more than 1 year. The aim of this study was to determine the characteristics and outcomes of the first repeat CA after VLR of AF after index CA. METHODS AND RESULTS: We analysed patients from a prospective Swiss registry that underwent a first repeat ablation procedure. Patients were stratified depending on the time to recurrence after index procedure: early recurrence (ER) for recurrences within the first year and late recurrence (LR) if the recurrence was later. The primary endpoint was freedom from AF in the first year after repeat ablation. Out of 1864 patients included in the registry, 426 patients undergoing a repeat ablation were included in the analysis (28% female, age 63 ± 9.8 years, 46% persistent AF). Two hundred and ninety-one patients (68%) were stratified in the ER group and 135 patients (32%) in the LR group. Pulmonary vein reconnections were a common finding in both groups, with 93% in the ER group compared to 86% in the LR group (P = 0.052). In the LR group, 40 of 135 patients (30%) had a recurrence of AF compared to 90 of 291 patients (31%) in the ER group (log-rank P = 0.72). CONCLUSION: There was no association between the time to recurrence of AF after initial CA and the characteristics and outcomes of the repeat procedure.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Recidiva , Sistema de Registros , Reoperação , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Masculino , Pessoa de Meia-Idade , Idoso , Fatores de Tempo , Suíça/epidemiologia , Fatores de Risco , Resultado do Tratamento , Estudos Prospectivos
4.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38693772

RESUMO

AIMS: Arrhythmia-induced cardiomyopathy (AiCM) represents a subtype of acute heart failure (HF) in the context of sustained arrhythmia. Clear definitions and management recommendations for AiCM are lacking. The European Heart Rhythm Association Scientific Initiatives Committee (EHRA SIC) conducted a survey to explore the current definitions and management of patients with AiCM among European and non-European electrophysiologists. METHODS AND RESULTS: A 25-item online questionnaire was developed and distributed among EP specialists on the EHRA SIC website and on social media between 4 September and 5 October 2023. Of the 206 respondents, 16% were female and 61% were between 30 and 49 years old. Most of the respondents were EP specialists (81%) working at university hospitals (47%). While most participants (67%) agreed that AiCM should be defined as a left ventricular ejection fraction (LVEF) impairment after new onset of an arrhythmia, only 35% identified a specific LVEF drop to diagnose AiCM with a wide range of values (5-20% LVEF drop). Most respondents considered all available therapies: catheter ablation (93%), electrical cardioversion (83%), antiarrhythmic drugs (76%), and adjuvant HF treatment (76%). A total of 83% of respondents indicated that adjuvant HF treatment should be started at first HF diagnosis prior to antiarrhythmic treatment, and 84% agreed it should be stopped within six months after LVEF normalization. Responses for the optimal time point for the first LVEF reassessment during follow-up varied markedly (1 day-6 months after antiarrhythmic treatment). CONCLUSION: This EHRA Survey reveals varying practices regarding AiCM among physicians, highlighting a lack of consensus and heterogenous care of these patients.


Assuntos
Arritmias Cardíacas , Cardiomiopatias , Humanos , Arritmias Cardíacas/terapia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Feminino , Masculino , Cardiomiopatias/terapia , Cardiomiopatias/diagnóstico , Cardiomiopatias/fisiopatologia , Pessoa de Meia-Idade , Adulto , Europa (Continente) , Inquéritos e Questionários , Volume Sistólico , Pesquisas sobre Atenção à Saúde , Antiarrítmicos/uso terapêutico , Padrões de Prática Médica/estatística & dados numéricos , Função Ventricular Esquerda , Ablação por Cateter , Cardiologistas
5.
Europace ; 26(7)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38954426

RESUMO

AIMS: Prior case series showed promising results for cardioneuroablation in patients with vagally induced atrioventricular blocks (VAVBs). We aimed to examine the acute procedural characteristics and intermediate-term outcomes of electroanatomical-guided cardioneuroablation (EACNA) in patients with VAVB. METHODS AND RESULTS: This international multicentre retrospective registry included data collected from 20 centres. Patients presenting with symptomatic paroxysmal or persistent VAVB were included in the study. All patients underwent EACNA. Procedural success was defined by the acute reversal of atrioventricular blocks (AVBs) and complete abolition of atropine response. The primary outcome was occurrence of syncope and daytime second- or advanced-degree AVB on serial prolonged electrocardiogram monitoring during follow-up. A total of 130 patients underwent EACNA. Acute procedural success was achieved in 96.2% of the cases. During a median follow-up of 300 days (150, 496), the primary outcome occurred in 17/125 (14%) cases with acute procedural success (recurrence of AVB in 9 and new syncope in 8 cases). Operator experience and use of extracardiac vagal stimulation were similar for patients with and without primary outcomes. A history of atrial fibrillation, hypertension, and coronary artery disease was associated with a higher primary outcome occurrence. Only four patients with primary outcome required pacemaker placement during follow-up. CONCLUSION: This is the largest multicentre study demonstrating the feasibility of EACNA with encouraging intermediate-term outcomes in selected patients with VAVB. Studies investigating the effect on burden of daytime symptoms caused by the AVB are required to confirm these findings.


Assuntos
Bloqueio Atrioventricular , Sistema de Registros , Humanos , Masculino , Feminino , Estudos Retrospectivos , Idoso , Pessoa de Meia-Idade , Resultado do Tratamento , Bloqueio Atrioventricular/fisiopatologia , Bloqueio Atrioventricular/terapia , Bloqueio Atrioventricular/cirurgia , Ablação por Cateter/métodos , Fatores de Tempo , Estimulação do Nervo Vago/métodos , Técnicas Eletrofisiológicas Cardíacas , Síncope/etiologia , Recidiva , Nó Atrioventricular/cirurgia , Nó Atrioventricular/fisiopatologia
6.
J Cardiovasc Electrophysiol ; 34(6): 1464-1468, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37146212

RESUMO

INTRODUCTION: Electrophysiological testing has been proposed in the latest European Society of Cardiology (ESC) guidelines for cardiac pacing to identify left bundle branch block (LBBB) patients with infrahisian conduction delay (IHCD) after transcatheter aortic valve replacement (TAVR). While in general IHCD is defined by a His-ventricular (HV) interval of >55 ms, a cut-off of ≥70 ms to trigger pacemaker (PM) implantation has been proposed in the latest ESC guidelines. The ventricular pacing (VP) burden during follow-up in such patients is largely unknown. As such, we aimed to assess the VP burden during follow-up of patients receiving PM therapy for LBBB after TAVR based on an HV interval > 55 ms and ≥70 ms. METHODS: All patients with new-onset or pre-existing LBBB after undergoing TAVR at a tertiary referral center underwent EP testing the day after TAVR. In patients with a prolonged HV interval (>55 ms), PM implantation was performed by a trained electrophysiologist in a standardized fashion. All devices were programmed to avoid unnecessary VP by specific algorithms (e.g., AAI-DDD). RESULTS: 701 patients underwent TAVR at the University Hospital of Basel. One hundred seventy-seven patients presented with new-onset or pre-existing LBBB the day following TAVR and underwent EP testing. An HV interval > 55 ms was found in 58 patients (33%) and an HV interval ≥ 70 ms in 21 patients (12%). 51 patients (mean age 84 ± 6.2 years, 45% women) agreed to receive a PM, out of which 20 (39%) patients had an HV Interval over 70 ms. Atrial fibrillation was present in 53% of the patients. A dual chamber PM was implanted in 39 (77%), and a single chamber PC in 12 (23%) patients, respectively. Median follow-up was 21 months. The median VP burden overall was 3%. The median VP burden was not significantly different between patients with an HV ≥ 70 ms (6.5 [0.8-52]) and those with an HV between 55 and 69 ms (2 [0-17], p = .23). 31% of patients demonstrated a VP burden < 1%, 27% 1%-5% and 41% > 5%. The median HV intervals in patients with VP burdens < 1%, 1%-5% and >5% were 66 (IQR 62-70) ms, 66 (IQR 63-74) ms and 68 (IQR 60-72) ms, respectively, p = .52. When only assessing patients with an HV interval 55-69 ms, 36% demonstrated a VP burden of <1%, 29% of 1%-5% and 35% of >5%. In patients with an HV Interval ≥ 70 ms, 25% demonstrated a VP burden < 1%, 25% of 1%-5% and 50% of >5% %, p = .64 (Figure). CONCLUSION: In patients with LBBB after TAVR and IHCD defined by an HV interval > 55 ms, VP burden is relevant in a non-negligible amount of patients during follow-up. Further studies are warranted to define the optimal cut-off value for the HV interval or to develop risk models incorporating HV measurements and other risk factors to trigger PM implantation in patients with LBBB after TAVR.


Assuntos
Estenose da Valva Aórtica , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/terapia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Arritmias Cardíacas/terapia , Marca-Passo Artificial/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia
7.
Europace ; 2023 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-37165671

RESUMO

BACKGROUND: Bipolar voltage (BV) electrograms for left atrial (LA) substrate characterization depend on catheter design and electrode configuration. AIMS: The aim of the study was to investigate the relationship between the BV amplitude (BVA) using four catheters with different electrode design and to identify their specific LA cutoffs for scar and healthy tissue. METHODS AND RESULTS: Consecutive high-resolution electroanatomic mapping was performed using a multipolar-minielectrode Orion catheter (Orion-map), a duo-decapolar circular mapping catheter (Lasso-map), and an irrigated focal ablation catheter with minielectrodes (Mifi-map). Virtual remapping using the Mifi-map was performed with a 4.5 mm tip-size electrode configuration (Nav-map). BVAs were compared in voxels of 3 × 3 × 3 mm3. The equivalent BVA cutoff for every catheter was calculated for established reference cutoff values of 0.1, 0.2, 0.5, 1.0, and 1.5 mV. We analyzed 25 patients (72% men, age 68 ± 15 years). For scar tissue, a 0.5 mV cutoff using the Nav corresponds to a lower cutoff of 0.35 mV for the Orion and of 0.48 mV for the Lasso. Accordingly, a 0.2 mV cutoff corresponds to a cutoff of 0.09 mV for the Orion and of 0.14 mV for the Lasso. For healthy tissue cutoff at 1.5 mV, a larger BVA cutoff for the small electrodes of the Orion and the Lasso was determined of 1.68 and 2.21 mV, respectively. CONCLUSION: When measuring LA BVA, significant differences were seen between focal, multielectrode, and minielectrode catheters. Adapted cutoffs for scar and healthy tissue are required for different catheters.

8.
Europace ; 25(12)2023 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-38036293

RESUMO

AIMS: Pulsed-field ablation (PFA) has emerged as a novel treatment technology for patients with atrial fibrillation (AF). Cryoballoon (CB) is the most frequently used single shot technology. A direct comparison to a novel CB system is lacking. We aimed to compare pulmonary vein isolation (PVI) using PFA vs. a novel CB system regarding efficiency, safety, myocardial injury, and outcomes. METHODS AND RESULTS: One hundred and eighty-one consecutive patients underwent PVI and were included (age 64 ± 9.7 years, ejection fraction 0.58 ± 0.09, left atrial size 40 ± 6.4 mm, paroxysmal AF 64%). 106 patients (59%) underwent PFA (FARAPULSE, Boston Scientific) and 75 patients (41%) underwent CB ablation (PolarX, Boston Scientific). The median procedure time, left atrial dwell time and fluoroscopic time were similar between the PFA and the CB group with 55 [interquartile range (IQR) 43-64] min vs. 58 (IQR 48-69) min (P < 0.087), 38 (30-49) min vs. 37 (31-48) min, (P = 0.871), and 11 (IQR 9.3-14) min vs. 11 (IQR 8.7-16) min, (P < 0.81), respectively. Three procedural complications were observed in the PFA group (two tamponades, one temporary ST elevation) and three complications in the CB group (3× reversible phrenic nerve palsies). During the median follow-up of 404 days (IQR 208-560), AF recurrence was similar in the PFA group and the CB group with 24 vs. 30%, P = 0.406. CONCLUSION: Procedural characteristics were very similar between PFA and CB in regard to procedure duration fluoroscopy time and complications. Atrial fibrillation free survival did not differ between the PFA and CB groups.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Pessoa de Meia-Idade , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
9.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37944133

RESUMO

AIMS: Pulmonary vein isolation (PVI) plays a central role in the interventional treatment of atrial fibrillation (AF). Uncertainties remain about the durability of ablation lesions from different energy sources. We aimed to systematically review the durability of ablation lesions associated with various PVI-techniques using different energy sources for the treatment of AF. METHODS AND RESULTS: Structured systematic database search for articles published between January 2010 and January 2023 reporting PVI-lesion durability as evaluated in the overall cohort through repeat invasive remapping during follow-up. Studies evaluating only a proportion of the initial cohort in redo procedures were excluded. A total of 19 studies investigating 1050 patients (mean age 60 years, 31% women, time to remap 2-7 months) were included. In a pooled analysis, 99.7% of the PVs and 99.4% of patients were successfully ablated at baseline and 75.5% of the PVs remained isolated and 51% of the patients had all PVs persistently isolated at follow-up across all energy sources. In a pooled analysis of the percentages of PVs durably isolated during follow-up, the estimates of RFA were the lowest of all energy sources at 71% (95% CI 69-73, 11 studies), but comparable with cryoballoon (79%, 95%CI 74-83, 3 studies). Higher durability percentages were reported in PVs ablated with laser-balloon (84%, 95%CI 78-89, one study) and PFA (87%, 95%CI 84-90, 2 studies). CONCLUSION: We observed no significant difference in the durability of the ablation lesions of the four evaluated energies after adjusting for procedural and baseline populational characteristics.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Fatores de Tempo , Resultado do Tratamento , Recidiva
10.
Europace ; 25(6)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37314197

RESUMO

AIMS: Atrial remodelling, defined as a change in atrial structure, promotes atrial fibrillation (AF). Bone morphogenetic protein 10 (BMP10) is an atrial-specific biomarker released to blood during atrial development and structural changes. We aimed to validate whether BMP10 is associated with AF recurrence after catheter ablation (CA) in a large cohort of patients. METHODS AND RESULTS: We measured baseline BMP10 plasma concentrations in AF patients who underwent a first elective CA in the prospective Swiss-AF-PVI cohort study. The primary outcome was AF recurrence lasting longer than 30 s during a follow-up of 12 months. We constructed multivariable Cox proportional hazard models to determine the association of BMP10 and AF recurrence. A total of 1112 patients with AF (age 61 ± 10 years, 74% male, 60% paroxysmal AF) was included in our analysis. During 12 months of follow-up, 374 patients (34%) experienced AF recurrence. The probability for AF recurrence increased with increasing BMP10 concentration. In an unadjusted Cox proportional hazard model, a per-unit increase in log-transformed BMP10 was associated with a hazard ratio (HR) of 2.28 (95% CI 1.43; 3.62, P < 0.001) for AF recurrence. After multivariable adjustment, the HR of BMP10 for AF recurrence was 1.98 (95% CI 1.14; 3.42, P = 0.01), and there was a linear trend across BMP10 quartiles (P = 0.02 for linear trend). CONCLUSION: The novel atrial-specific biomarker BMP10 was strongly associated with AF recurrence in patients undergoing CA for AF. CLINICALTRIALS.GOV IDENTIFIER: NCT03718364; https://clinicaltrials.gov/ct2/show/NCT03718364.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos de Coortes , Estudos Prospectivos , Proteínas Morfogenéticas Ósseas , Ablação por Cateter/efeitos adversos
11.
Ann Emerg Med ; 82(2): 194-202, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36774205

RESUMO

STUDY OBJECTIVE: The diagnostic performance of T-wave amplitudes for the detection of myocardial infarction is largely unknown. We aimed to address this knowledge gap. METHODS: T-wave amplitudes were automatically measured in 12-lead ECGs of patients presenting with acute chest discomfort to the emergency department within a prospective diagnostic multicenter study. The final diagnosis was centrally adjudicated by 2 independent cardiologists. Patients with left ventricular hypertrophy, complete left bundle branch block, or paced ventricular depolarization were excluded. The performance for lead-specific 95th-percentile thresholds were reported as likelihood ratios (lr), specificity, and sensitivity. RESULTS: Myocardial infarction was the final diagnosis in 445 (18%) of 2457 patients. In most leads, T-wave amplitudes tended to be greater in patients without myocardial infarction than those with myocardial infarction, and T-wave amplitude exceeding the 95th percentile had positive and negative lr close to 1 or with confidence intervals (CIs) crossing 1. The exceptions were leads III, aVR, and V1, which had positive lrs of 3.8 (95% CI, 2.7 to 5.3), 4.3 (95% CI, 3.1 to 6.0) and 2.0 (95% CI, 1.4 to 2.9), respectively. These leads normally have inverted T waves, so T-wave amplitude exceeding the 95th percentile reflects upright rather than increased-amplitude hyperacute T waves. CONCLUSION: Hyperacute T waves, when defined as increased T-wave amplitude exceeding the 95th percentile, did not provide useful information in diagnosing myocardial infarction in this sample.


Assuntos
Infarto do Miocárdio , Humanos , Estudos Prospectivos , Sensibilidade e Especificidade , Infarto do Miocárdio/diagnóstico , Arritmias Cardíacas , Eletrocardiografia , Diagnóstico Precoce
12.
Pacing Clin Electrophysiol ; 46(10): 1186-1196, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37616339

RESUMO

BACKGROUND: Prediction of the chamber of origin in patients with outflow tract ventricular arrhythmias (OTVA) remains challenging. A clinical risk score based on age, sex and presence of hypertension was associated with a left ventricular outflow tract (LVOT) origin. We aimed to validate this clinical score to predict an LVOT origin in patients with OTVA. METHODS: In a two-center observational cohort study, unselected patients undergoing catheter ablation (CA) for OTVA were enrolled. All procedures were performed using an electroanatomical mapping system. Successful ablation was defined as a ≥80% reduction of the initial overall PVC burden after 3 months of follow-up. Patients with unsuccessful ablation were excluded from this analysis. RESULTS: We included 187 consecutive patients with successful CA of idiopathic OTVA. Mean age was 52 ± 15 years, 102 patients (55%) were female, and 74 (40%) suffered from hypertension. A LVOT origin was found in 64 patients (34%). A score incorporating age, sex and presence of hypertension reached 73% sensitivity and 67% specificity for a low (0-1) and high (2-3) score, to predict an LVOT origin. The combination of one ECG algorithm (V2 S/V3 R-index) with the clinical score resulted in a sensitivity and specificity of 81% and 70% for PVCs with R/S transition at V3 . CONCLUSION: The published clinical score yielded a lower sensitivity and specificity in our cohort. However, for PVCs with R/S transition at V3, the combination with an existing ECG algorithm can improve the predictability of LVOT origin.

13.
Ann Intern Med ; 175(6): 783-794, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35467933

RESUMO

BACKGROUND: The Canadian Syncope Risk Score (CSRS) was developed to predict 30-day serious outcomes not evident during emergency department (ED) evaluation. OBJECTIVE: To externally validate the CSRS and compare it with another validated score, the Osservatorio Epidemiologico della Sincope nel Lazio (OESIL) score. DESIGN: Prospective cohort study. SETTING: Large, international, multicenter study recruiting patients in EDs in 8 countries on 3 continents. PARTICIPANTS: Patients with syncope aged 40 years or older presenting to the ED within 12 hours of syncope. MEASUREMENTS: Composite outcome of serious clinical plus procedural events (primary outcome) and the primary composite outcome excluding procedural interventions (secondary outcome). RESULTS: Among 2283 patients with a mean age of 68 years, the primary composite outcome occurred in 7.2%, and the composite outcome excluding procedural interventions occurred in 3.1% at 30 days. Prognostic performance of the CSRS was good for both 30-day composite outcomes and better compared with the OESIL score (area under the receiver-operating characteristic curve [AUC], 0.85 [95% CI, 0.83 to 0.88] vs. 0.74 [CI, 0.71 to 0.78] and 0.80 [CI, 0.75 to 0.84] vs. 0.69 [CI, 0.64 to 0.75], respectively). Safety of triage, as measured by the frequency of the primary composite outcome in the low-risk group, was higher using the CSRS (19 of 1388 [0.6%]) versus the OESIL score (17 of 1104 [1.5%]). A simplified model including only the clinician classification of syncope (cardiac syncope, vasovagal syncope, or other) variable at ED discharge-a component of the CSRS-achieved similar discrimination as the CSRS (AUC, 0.83 [CI, 0.80 to 0.87] for the primary composite outcome). LIMITATION: Unable to disentangle the influence of other CSRS components on clinician classification of syncope at ED discharge. CONCLUSION: This international external validation of the CSRS showed good performance in identifying patients at low risk for serious outcomes outside of Canada and superior performance compared with the OESIL score. However, clinician classification of syncope at ED discharge seems to explain much of the performance of the CSRS in this study. The clinical utility of the CSRS remains uncertain. PRIMARY FUNDING SOURCE: Swiss National Science Foundation & Swiss Heart Foundation.


Assuntos
Serviço Hospitalar de Emergência , Síncope , Idoso , Canadá , Estudos de Coortes , Humanos , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Síncope/diagnóstico , Síncope/terapia
14.
N Engl J Med ; 380(26): 2529-2540, 2019 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-31242362

RESUMO

BACKGROUND: Data regarding high-sensitivity troponin concentrations in patients presenting to the emergency department with symptoms suggestive of myocardial infarction may be useful in determining the probability of myocardial infarction and subsequent 30-day outcomes. METHODS: In 15 international cohorts of patients presenting to the emergency department with symptoms suggestive of myocardial infarction, we determined the concentrations of high-sensitivity troponin I or high-sensitivity troponin T at presentation and after early or late serial sampling. The diagnostic and prognostic performance of multiple high-sensitivity troponin cutoff combinations was assessed with the use of a derivation-validation design. A risk-assessment tool that was based on these data was developed to estimate the risk of index myocardial infarction and of subsequent myocardial infarction or death at 30 days. RESULTS: Among 22,651 patients (9604 in the derivation data set and 13,047 in the validation data set), the prevalence of myocardial infarction was 15.3%. Lower high-sensitivity troponin concentrations at presentation and smaller absolute changes during serial sampling were associated with a lower likelihood of myocardial infarction and a lower short-term risk of cardiovascular events. For example, high-sensitivity troponin I concentrations of less than 6 ng per liter and an absolute change of less than 4 ng per liter after 45 to 120 minutes (early serial sampling) resulted in a negative predictive value of 99.5% for myocardial infarction, with an associated 30-day risk of subsequent myocardial infarction or death of 0.2%; a total of 56.5% of the patients would be classified as being at low risk. These findings were confirmed in an external validation data set. CONCLUSIONS: A risk-assessment tool, which we developed to integrate the high-sensitivity troponin I or troponin T concentration at emergency department presentation, its dynamic change during serial sampling, and the time between the obtaining of samples, was used to estimate the probability of myocardial infarction on emergency department presentation and 30-day outcomes. (Funded by the German Center for Cardiovascular Research [DZHK]; ClinicalTrials.gov numbers, NCT00470587, NCT02355457, NCT01852123, NCT01994577, and NCT03227159; and Australian New Zealand Clinical Trials Registry numbers, ACTRN12611001069943, ACTRN12610000766011, ACTRN12613000745741, and ACTRN12611000206921.).


Assuntos
Infarto do Miocárdio/sangue , Infarto do Miocárdio/diagnóstico , Medição de Risco/métodos , Troponina/sangue , Adulto , Idoso , Biomarcadores/sangue , Estudos de Coortes , Serviço Hospitalar de Emergência , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Sensibilidade e Especificidade , Troponina I/sangue
15.
Biomarkers ; 27(3): 278-285, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35112976

RESUMO

BACKGROUND: Soluble urokinase plasminogen activator receptor (suPAR) is an emerging biomarker associated with anatomical CAD burden and cardiovascular outcomes including myocardial infarction (MI) and death. We aimed to validate previous findings of the prognostic value of suPAR and to evaluate its diagnostic potential for functional relevant CAD (fCAD). METHODS: Consecutive patients with suspected fCAD were enrolled. Adjudication of fCAD was performed blinded to suPAR concentrations by myocardial perfusion single-photon emission tomography (MPI-SPECT) and coronary angiography. Prognostic outcome measures included all-cause death, cardiovascular death, and incident MI during 2-year follow-up. RESULTS: Among consecutive 968 patients, suPAR concentrations were higher in patients with fCAD compared to those without (3.45 vs. 3.20 ng/mL, p = 0.007), but did not provide acceptable diagnostic accuracy (area under the curve [AUC]: 0.56, 95%CI 0.52-0.60). SuPAR correlated with high-sensitivity cardiac-troponin T (Spearman's rho (ρ) 0.393, p < 0.001), NT-proBNP (ρ = 0.327, p < 0.001), age (ρ = 0.364, p < 0.001) and very weakly with coronary atherosclerosis (ρ = 0.123, p < 0.001). Prognostic discrimination of suPAR was moderate for cardiovascular death (AUC = 0.72, 95%CI 0.62-0.81) and all-cause death (AUC = 0.72, 95%CI 0.65-0.79) at 2-years. SuPAR remained a significant predictor for all-cause death in multivariable Cox regression (HR = 1.96, p = 0.001). CONCLUSIONS: SuPAR was an independent predictor of all-cause death, without diagnostic utility for fCAD. CLINICAL TRIAL REGISTRATION: NCT01838148.


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Biomarcadores , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Humanos , Infarto do Miocárdio/diagnóstico , Prognóstico , Estudos Prospectivos , Receptores de Ativador de Plasminogênio Tipo Uroquinase
16.
Europace ; 24(7): 1179-1185, 2022 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-35348646

RESUMO

Conduction disorders such as left bundle branch block (LBBB) are common after transcatheter aortic valve implantation (TAVI). Consensus regarding a reasonable strategy to manage conduction disturbances after TAVI has been elusive. The European Heart Rhythm Association (EHRA) conducted a survey to capture contemporary clinical practice for conduction disorders after TAVI. A 25-item online questionnaire was developed and distributed among the EHRA electrophysiology (EP) research network centres. Of 117 respondents, 44% were affiliated with university hospitals. A standardized management protocol for advanced conduction disorders such as LBBB or atrioventricular block (AVB) after TAVI was available in 63% of participating centres. Telemetry after TAVI was chosen as the most frequent management strategy for patients with new-onset or pre-existing LBBB (79% and 70%, respectively). Duration of telemetry in patients with new-onset LBBB varied, with a 48-h period being the most frequently chosen, but almost half monitoring continued for at least 72 h. Similarly, in patients undergoing EP study due to new-onset LBBB, the HV interval cut-off point leading to pacemaker implantation was heterogeneous among European centres, although an HV >75 ms threshold was the most common. Conduction system pacing was chosen as a preferred approach by 3.7% of respondents for patients with LBBB and normal left ventricular ejection fraction (LVEF), and by 5.6% for patients with LBBB and reduced LVEF. This survey suggests some heterogenity in the management of conduction disorders after TAVI across European centres. The risk stratification strategies vary substantially. Conduction system pacing in patients with LBBB after TAVI is still underused.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica , Estenose da Valva Aórtica/cirurgia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/etiologia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/epidemiologia , Bloqueio de Ramo/etiologia , Doença do Sistema de Condução Cardíaco/diagnóstico , Doença do Sistema de Condução Cardíaco/epidemiologia , Doença do Sistema de Condução Cardíaco/terapia , Humanos , Volume Sistólico , Inquéritos e Questionários , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda
17.
Europace ; 24(12): 1926-1932, 2022 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-35727739

RESUMO

AIMS: The aim of the study was to compare the 1-year efficacy and safety of a novel cryoballoon (NCB) ablation system (POLARx; Boston Scientific) for pulmonary vein isolation (PVI) compared with the standard cryoballoon (SCB) system (Arctic Front, Medtronic). METHODS AND RESULTS: Consecutive patients with atrial fibrillation (AF) undergoing PVI using the NCB and the SCB at two centres were included. We report 1-year efficacy after 12 months, short-term safety and hospitalizations within the blanking period, and predictors for AF recurrence. In case of repeat procedures, pulmonary vein (PV) reconnection patterns were characterized. Eighty patients (age 66 ± 10 years, ejection fraction 57 ± 10%, left atrial volume index 39 ± 13 mL/m2, paroxysmal AF in 64%) were studied. After a single procedure and a follow-up of 12 months, 68% in the NCB group and 70% in the SCB group showed no recurrence of AF/atrial tachycardias (P = 0.422). One patient in the NCB group suffered a periprocedural stroke with full recovery. There were no differences regarding hospitalizations during follow-up between the groups. PV reconnection observed during 12 repeat procedures (4 NCB, 8 SCB) pattern was comparable between the groups with more reconnections in the right-sided compared with the left-sided PVs. CONCLUSION: In this multicentre study comparing two currently available cryoballoon ablation systems for PVI, no differences were observed in the efficacy and safety during a follow-up of 12 months.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Pessoa de Meia-Idade , Idoso , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
18.
J Cardiovasc Electrophysiol ; 32(4): 1077-1084, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33650717

RESUMO

INTRODUCTION: Catheter ablation (CA) of frequent premature ventricular contractions (PVC) is increasingly performed in older patients as the population ages. The aim of this study was to assess the impact of age on procedural characteristics, safety and efficacy on PVC ablations. METHODS: Consecutive patients with symptomatic PVCs undergoing CA between 2015 and 2020 were evaluated. Acute ablation success was defined as the elimination of PVCs at the end of the procedure. Sustained success was defined as an elimination of symptoms, and ≥80% reduction of PVC burden determined by Holter-electrocardiogram during long-term follow. Patients were sub-grouped based on age (<65 vs. ≥65 years). RESULTS: A total of 114 patients were enrolled (median age 64 years, 71% males) and followed up for a median duration of 228 days. Baseline and procedural data were similar in both age groups. A left-sided origin of PVCs was more frequently observed in the elderly patient group compared to younger patients (83% vs. 67%; p = .04). The median procedure time was significantly shorter in elderly patients (160 vs. 193 min; p = .02). The rates of both acute (86% vs. 92%; p = .32) and sustained success (70% vs. 71%; p = .90) were similar between groups. Complications rates (3.7%) did not differ between the two groups. CONCLUSION: In a large series of patients with a variety of underlying arrhythmia substrates, similar rates of acute procedural success, complications, and ventricular arrhythmia-free-survival were observed after CA of PVCs. Older age alone should not be a reason to withhold CA of PVCs.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Idoso , Ablação por Cateter/efeitos adversos , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia
19.
Pacing Clin Electrophysiol ; 44(4): 703-710, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33675240

RESUMO

BACKGROUND: Radiofrequency catheter ablation of idiopathic premature ventricular complexes (PVCs) is an effective method for eliminating symptoms and preventing/reversing arrhythmia-induced cardiomyopathy. One reason for procedural failure is low PVC frequency during the procedure. We aimed to investigate the relation between pre-procedural PVC burden and outcome of idiopathic PVC catheter ablation. METHODS: Patients who underwent idiopathic PVC ablation between 2013 and 2019 at two tertiary referral centers were retrospectively included. All procedures were performed using irrigated-tip ablation catheters and a 3D electro-anatomical mapping system. Sustained ablation success was defined as a ≥80% reduction of pre-procedural PVC burden determined by 24h-Holter at follow-up. RESULTS: Overall, 254 patients (median age 54 years [IQR 42-64]; 47% male) were enrolled. The median pre-ablation PVC-burden was 22% (IQR 11-31%), which was reduced to a post-ablation PVC burden of 0.3% (IQR 0-4%) after a median of 90 days. Sustained ablation success was achieved in 182 patients (72%). Pre-procedural PVC burden did not differ between patients with sustained ablation success and recurrence during follow-up (median 21% vs. 22%, p = .76). When assessed in pre-ablation PVC-burden groups of ≤5%, 6-15%, 16-30%, and ≥31%, sustained ablation success was achieved in 67%, 75%, 71%, and 72%, respectively, with no significant difference (p = .89). Sustained ablation outcome for PVC-burden ≤5% versus >5% showed no difference either (67% vs. 72%, p = .52). CONCLUSIONS: Pre-procedural Holter-determined PVC burden does not predict the outcome of idiopathic PVC ablation. Thus, catheter ablation may be a reasonable first choice also for patients with symptomatic yet rare PVCs.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/cirurgia , Adulto , Idoso , Eletrocardiografia Ambulatorial , Mapeamento Epicárdico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Suíça
20.
Ann Intern Med ; 172(3): 175-185, 2020 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-31905377

RESUMO

Background: The optimal noninvasive method for surveillance in symptomatic patients with stable coronary artery disease (CAD) is unknown. Objective: To apply a novel approach using very low concentrations of high-sensitivity cardiac troponin I (hs-cTnI) for exclusion of inducible myocardial ischemia in symptomatic patients with CAD. Design: Prospective diagnostic cohort study. (ClinicalTrials.gov: NCT01838148). Setting: University hospital. Patients: 1896 consecutive patients with CAD referred with symptoms possibly related to inducible myocardial ischemia. Measurements: Presence of inducible myocardial ischemia was adjudicated using myocardial perfusion imaging with single-photon emission computed tomography, as well as coronary angiography and fractional flow reserve measurements where available. Staff blinded to adjudication measured circulating hs-cTn concentrations. An hs-cTnI cutoff of 2.5 ng/L, derived previously in mostly asymptomatic patients with CAD, was assessed. Predefined target performance criteria were at least 90% negative predictive value (NPV) and at least 90% sensitivity for exclusion of inducible myocardial ischemia. Sensitivity analyses were based on measurements with an hs-cTnT assay and an alternative hs-cTnI assay with even higher analytic sensitivity (limit of detection, 0.1 ng/L). Results: Overall, 865 patients (46%) had inducible myocardial ischemia. The hs-cTnI cutoff of 2.5 ng/L provided an NPV of 70% (95% CI, 64% to 75%) and a sensitivity of 90% (CI, 88% to 92%) for exclusion of inducible myocardial ischemia. No hs-cTnI cutoff reached both performance characteristics predefined as targets. Similarly, using the alternative assays for hs-cTnI or hs-cTnT, no cutoff achieved the target performance: hs-cTnT concentrations less than 5 ng/L yielded an NPV of 66% (CI, 59% to 72%), and hs-cTnI concentrations less than 2 ng/L yielded an NPV of 68% (CI, 62% to 74%). Limitation: Data were generated in a large single-center diagnostic study using central adjudication. Conclusion: In symptomatic patients with CAD, very low hs-cTn concentrations, including hs-cTnI concentrations less than 2.5 ng/L, do not generally allow users to safely exclude inducible myocardial ischemia. Primary Funding Source: European Union, Swiss National Science Foundation, Kommission für Technologie und Innovation (Innosuisse), Swiss Heart Foundation, Cardiovascular Research Foundation Basel, University of Basel, University Hospital Basel, Roche, Abbott, and Singulex.


Assuntos
Doença da Artéria Coronariana/sangue , Isquemia Miocárdica/sangue , Isquemia Miocárdica/diagnóstico , Troponina I/sangue , Troponina T/sangue , Idoso , Biomarcadores/sangue , Estudos de Coortes , Angiografia Coronária , Feminino , Reserva Fracionada de Fluxo Miocárdico , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio , Valor Preditivo dos Testes , Tomografia Computadorizada de Emissão de Fóton Único
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA