1.
Clin Chem Lab Med ; 62(5): 881-890, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-37999931

RESUMO

OBJECTIVES: Blood microsampling, particularly dried blood spots (DBSs), is an attractive minimally-invasive approach that is well suited for home sampling and predictive medicine associated with longitudinal follow-up of the elderly. However, in vitro diagnostic quantification of biomarkers from DBS poses a major challenge. Clinical mass spectrometry can reliably quantify blood proteins in various research projects. Our goal here was to use mass spectrometry of DBS in a real-world clinical setting and compared it to the standard immunoassay method. We also sought to correlate DBS mass spectrometry measurements with clinical indices. METHODS: A clinical trial of diagnostic equivalence was conducted to compare conventional venous samples quantified by immunoassay and DBSs quantified by mass spectrometry in an elderly population. We assayed three protein biomarkers of nutritional and inflammatory status: prealbumin (transthyretin), C-reactive protein, and transferrin. RESULTS: The analysis of DBSs showed satisfactory variability and low detection limits. Statistical analysis confirmed that the two methods give comparable results at clinical levels of accuracy. In conclusion, we demonstrated, in a real-life setting, that DBSs can be used to measure prealbumin, CRP and transferrin, which are commonly used markers of nutritional status and inflammation in the elderly. However, there was no correlation with patient frailty for these proteins. CONCLUSIONS: Early detection and regular monitoring of nutritional and inflammatory problems using DBS appear to be clinically feasible. This could help resolve major public health challenges in the elderly for whom frailty leads to serious risks of health complications.


Assuntos
Fragilidade , Pré-Albumina , Idoso , Humanos , Espectrometria de Massas em Tandem/métodos , Biomarcadores , Teste em Amostras de Sangue Seco/métodos , Transferrinas
2.
J Med Virol ; 95(1): e28209, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36226380

RESUMO

In the early phase of the pandemic, we were among the first to postulate that neutrophil extracellular traps (NETs) play a key role in COVID-19 pathogenesis. This exploratory prospective study based on 279 individuals showed that plasma levels of neutrophil elastase, myeloperoxidase and circulating DNA of nuclear and mitochondrial origins in nonsevere (NS), severe (S) and postacute phase (PAP) COVID-19 patients were statistically different as compared to the levels in healthy individuals, and revealed the high diagnostic power of these NETs markers in respect to the disease severity. The diagnostic power of NE, MPO, and cir-nDNA as determined by the Area Under Receiver Operating Curves (AUROC) was 0.95, 097, and 0.64; 0.99, 1.0, and 0.82; and 0.94, 1.0, and 0.93, in NS, S, and PAP patient subgroups, respectively. In addition, a significant fraction of NS, S as well as of PAP patients exhibited aCL IgM/IgG and anti-B2GP IgM/IgG positivity. We first demonstrate persistence of these NETs markers in PAP patients and consequently of sustained innate immune response imbalance, and a prolonged low-level pro-thrombotic potential activity highlighting the need to monitor these markers in all COVID-19 PAP individuals, to investigate postacute COVID-19 pathogenesis following intensive care, and to better identify which medical resources will ensure complete patient recovery.


Assuntos
COVID-19 , Armadilhas Extracelulares , Humanos , Estudos Prospectivos , Anticorpos Anticardiolipina , COVID-19/patologia , Imunoglobulina G , Imunoglobulina M , Neutrófilos
3.
Int J Clin Pract ; 2023: 6652671, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38146346

RESUMO

Background: The prognostic value of vitamin B12 blood levels remains controversial. An association between elevated vitamin B12 and mortality has been reported, particularly among elderly patients with cancers and liver or blood diseases. The present study explored the relationship between mortality and elevated vitamin B12 levels in a population of unscheduled inpatients in an internal medicine unit. Methods: This retrospective observational analysis was conducted between August 2014 and December 2018. We compared 165 patients with elevated plasma vitamin B12 levels (>600 pmol/l) with a random sample of 165 patients with normal B12 levels who were hospitalized during the same period. Demographic, clinical, and biological characteristics were assessed during hospitalization. The primary endpoint was all-cause death at 1 year. Results: Patients with elevated B12 were younger, with a lower body mass index and lower plasma albumin than those with normal B12 (75 ± 16 years vs 79 ± 13 years, p = 0.047; 23 ± 5 vs 26 ± 7 kg/m2, p < 0.001; and 33 ± 5 vs 35 ± 5 g/l, p < 0.001, respectively). The prevalence of auto-immune disease and referral from an intensive care unit was higher among patients with elevated B12 (11% vs 5%, p = 0.043 and 36% vs 10%, p < 0.001, respectively). After 1 year of follow-up, 64 (39%) patients with elevated B12 had died compared to 43 (26%) patients with normal B12 (p = 0.018). Multivariate analysis using the Cox proportional hazards regression model adjusted for age, gender, body mass index, intensive care unit hospitalization, albumin level, and the presence of solid cancer or autoimmune disease revealed elevated B12 to be associated with a significant risk of death in the first year of follow-up (hazard ratio: 1.71 [1.08-2.7], p = 0.022). Conclusion: Elevated B12 is an early warning indicator of increased short-term mortality, such as independently of age, cancer, or comorbidities, in patients hospitalized in an internal medicine department.


Assuntos
Mortalidade Hospitalar , Vitamina B 12 , Idoso , Humanos , Comorbidade , Hospitalização , Estudos Retrospectivos , Vitamina B 12/sangue
4.
Ren Fail ; 45(2): 2292152, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38078385

RESUMO

Tubular injury is the main cause of acute kidney injury (AKI) in critically ill COVID-19 patients. Proximal tubular dysfunction (PTD) and changes in urinary biomarkers, such as NGAL, TIMP-2, and IGFBP7 product ([TIMP-2]•[IGFBP7]), could precede AKI. We conducted a prospective cohort study from 2020/03/09 to 2020/05/03, which consecutively included all COVID-19 patients who had at least one urinalysis, to assess the incidence of PTD and AKI, and the effectiveness of PTD, NGAL, and [TIMP-2]•[IGFBP7] in AKI and persistent AKI prediction using the area under the receiver operating characteristic curves (AUCs), Kaplan-Meier methodology (log-rank tests), and Cox models. Among the 60 patients admitted to the ICU with proven COVID-19 (median age: 63-year-old (interquartile range: IQR, 55-74), 45 males (75%), median simplified acute physiology score (SAPS) II: 34 (IQR, 22-47) and median BMI: 25.7 kg/m2 (IQR, 23.3-30.8)) analyzed, PTD was diagnosed in 29 patients (48%), AKI in 33 (55%) and persistent AKI in 20 (33%). Urinary NGAL had the highest AUC for AKI prediction: 0.635 (95%CI: 0.491-0.779) and persistent AKI prediction: 0.681 (95%CI: 0.535-0.826), as compared to PTD and [TIMP-2]•[IGFBP7] (AUCs <0.6). AKI was independently associated with higher SAPSII (HR = 1.04, 95%CI: 1.01-1.06, p = 0.005) and BMI (HR = 1.07, 95%CI: 1.00-1.14, p = 0.04) and persistent AKI with higher SAPSII (HR = 1.03, 95%CI: 1.00-1.06, p = 0.048) and nephrotoxic drug use (HR = 3.88, 95%CI: 1.20-12.5, p = 0.02). In conclusion, in critically ill COVID-19 patients, the incidence of PTD and AKI was relatively high. NGAL was the best urinary biomarker for predicting AKI, but only clinical severity was independently associated with its occurrence.


Assuntos
Injúria Renal Aguda , COVID-19 , Masculino , Humanos , Pessoa de Meia-Idade , Inibidor Tecidual de Metaloproteinase-2 , Estudos Prospectivos , Estado Terminal , Lipocalina-2 , COVID-19/complicações , Rim , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/etiologia , Biomarcadores
5.
Int J Mol Sci ; 24(8)2023 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-37108152

RESUMO

Blood microsampling combined with large panels of clinically relevant tests are of major interest for the development of home sampling and predictive medicine. The aim of the study was to demonstrate the practicality and medical utility of microsamples quantification using mass spectrometry (MS) in a clinical setting by comparing two types of microsamples for multiplex MS protein detection. In a clinical trial based on elderly population, we compared 2 µL of plasma to dried blood spot (DBS) with a clinical quantitative multiplex MS approach. The analysis of the microsamples allowed the quantification of 62 proteins with satisfactory analytical performances. A total of 48 proteins were significantly correlated between microsampling plasma and DBS (p < 0.0001). The quantification of 62 blood proteins allowed us to stratify patients according to their pathophysiological status. Apolipoproteins D and E were the best biomarker link to IADL (instrumental activities of daily living) score in microsampling plasma as well as in DBS. It is, thus, possible to detect multiple blood proteins from micro-samples in compliance with clinical requirements and this allows, for example, to monitor the nutritional or inflammatory status of patients. The implementation of this type of analysis opens new perspectives in the field of diagnosis, monitoring and risk assessment for personalized medicine approaches.


Assuntos
Monitoramento Biológico , Espectrometria de Massas em Tandem , Idoso , Humanos , Atividades Cotidianas , Proteínas Sanguíneas , Manejo de Espécimes , Espectrometria de Massas em Tandem/métodos
6.
Clin Chem Lab Med ; 60(11): 1763-1771, 2022 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-36096492

RESUMO

OBJECTIVES: Aldosterone and renin determinations play an important role in the etiological diagnosis of secondary hypertension. The analytical performances of new aldosterone and renin immunoassays on the Lumipulse G600II® system (Fujierbio) were investigated and compared with those of the iSYS® system (IDS) on patients concerned by medical investigations in a context of suspected or proven Primary aldosteronism. METHODS: By using the Lumipulse® G Aldosterone and Renin assays we performed imprecision study, linearity and method comparison (n=107). Accuracy of this new renin assay was tested using the International Standard (WHO IS 68/356). We also assessed the equivalence of the different samples types (n=29). RESULTS: The imprecision evaluation showed all CVs <3% and <6% for Lumipulse® G Aldosterone and Renin assays respectively. The linearity was excellent over the clinical range and the comparison with the iSYS® assays (n=79) showed a strong correlation (R2=1) despite a slight tendency to underestimation (bias of -17.53 pg/mL or 48.56 pmol/L for aldosterone and -15.395 pg/mL for renin). Moreover, the contingency studies based on diagnostic criteria showed that Lumipulse® G results lead to the same clinical diagnosis that iSYS® results. A clear correlation was obtained between EDTA and heparin plasma as well as with the serum for all range of measures. CONCLUSIONS: The Lumipulse® G Aldosterone and Renin assays present performances compatible with a routine use in medical laboratories. The precise quantification in the low range can be of interest in some clinical contexts especially standing/laying tests. However, the standardisation against the WHO International Standard Renin would be advisable.


Assuntos
Hiperaldosteronismo , Hipertensão , Aldosterona , Ácido Edético , Heparina , Humanos , Hiperaldosteronismo/diagnóstico , Imunoensaio/métodos , Renina
7.
Scand J Clin Lab Invest ; 81(4): 290-297, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33908840

RESUMO

Point of care testing makes it possible to obtain results in an extremely short time. Recently, radiometer has expanded the panel of tests available on its ABL90 FLEX PLUS blood gas analyzer (ABL90) by adding urea and creatinine. The aim of this study was to verify the performance of these new parameters. This included assessment of imprecision, linearity, accuracy by comparison with central laboratory standard assays and interferences. In addition, clinical utility in a dialysis center was evaluated. Within-lab coefficients of variation were close to 2%. The mean and limits of agreement (mean ± 1.96 SD) of the difference between ABL90 and Roche enzymatic assays on cobas 8000 were 0.5 (from -1.4 to 2.3) mmol/L and -0.9 (from -19.5 to 17.8) µmol/L for urea and creatinine, respectively. The ABL90 enzymatic urea and creatinine assays met the acceptance criteria based on biological variation for imprecision and showed good agreement with central laboratory. The two assays were unaffected by hematocrit variation between 20 and 70%, hemolysis and icterus interferences. It should be noted that the relationship between lab methods and ABL90 was conserved even for high pre-dialysis values allowing easy access to dialysis adequacy parameters (Kt/V) and muscle mass evaluation (creatinine index). Rapid measurement of creatinine and urea using whole blood specimens on ABL90 appears as a fast and convenient method. Analytical performances were in accordance with our expectations without any significant interferences by hemolysis or icterus.


Assuntos
Gasometria/instrumentação , Gasometria/métodos , Creatinina/sangue , Ureia/sangue , Idoso , Artefatos , Feminino , Hemólise , Humanos , Masculino , Testes Imediatos
8.
BMC Pediatr ; 21(1): 584, 2021 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-34930217

RESUMO

BACKGROUND: Tenfold or more overdose of a drug or preparation is a dreadful adverse event in neonatology, often due to an error in programming the infusion pump flow rate. Lipid overdose is exceptional in this context and has never been reported during the administration of a composite intravenous lipid emulsion (ILE). CASE PRESENTATION: Twenty-four hours after birth, a 30 weeks' gestation infant with a birthweight of 930 g inadvertently received 28 ml of a composite ILE over 4 h. The ILE contained 50% medium-chain triglycerides and 50% soybean oil, corresponding to 6 g/kg of lipids (25 mg/kg/min). The patient developed acute respiratory distress with echocardiographic markers of pulmonary hypertension and was treated with inhaled nitric oxide and high-frequency oscillatory ventilation. Serum triglyceride level peaked at 51.4 g/L, 17 h after the lipid overload. Triple-volume exchange transfusion was performed twice, decreasing the triglyceride concentration to < 10 g/L. The infant's condition remained critical, with persistent bleeding and shock despite supportive treatment and peritoneal dialysis. Death occurred 69 h after the overdose in a context of refractory lactic acidosis. CONCLUSIONS: Massive ILE overdose is life-threatening in the early neonatal period, particularly in premature and hypotrophic infants. This case highlights the vigilance required when ILEs are administered separately from other parenteral intakes. Exchange transfusion should be considered at the first signs of clinical or biological worsening to avoid progression to multiple organ failure.


Assuntos
Overdose de Drogas , Emulsões Gordurosas Intravenosas , Humanos , Lactente , Recém-Nascido , Nutrição Parenteral/efeitos adversos , Óleo de Soja , Triglicerídeos
9.
FASEB J ; 33(1): 339-357, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-29979629

RESUMO

Nonsteroidal antiinflammatory drugs and analgesic drugs, such as N-acetyl- p-aminophenol (APAP; acetaminophen, paracetamol), are widely used by pregnant women. Accumulating evidence has indicated that these molecules can favor genital malformations in newborn boys and reproductive disorders in adults. However, the consequences on postnatal testis development and adult reproductive health after exposure during early embryogenesis are still unknown. Using the mouse model, we show that in utero exposure to therapeutic doses of the widely used APAP-ibuprofen combination during the sex determination period leads to early differentiation and decreased proliferation of male embryonic germ cells, and early 5-methylcytosine and extracellular matrix protein deposition in 13.5 d postcoitum exposed testes. Consequently, in postnatal testes, Sertoli-cell maturation is delayed, the Leydig-cell compartment is hyperplasic, and the spermatogonia A pool is decreased. This results in a reduced production of testosterone and in epididymal sperm parameter defects. We observed a reduced sperm count (19%) in utero-exposed (F0) adult males and also a reduced sperm motility (40%) in their offspring (F1) when both parents were exposed, which leads to subfertility among the 6 mo old F1 animals. Our study suggests that the use of these drugs during the critical period of sex determination affects the germ-line development and leads to adverse effects that could be passed to the offspring.-Rossitto, M., Marchive, C., Pruvost, A., Sellem, E., Ghettas, A., Badiou, S., Sutra, T., Poulat, F., Philibert, P., Boizet-Bonhoure, B. Intergenerational effects on mouse sperm quality after in utero exposure to acetaminophen and ibuprofen.


Assuntos
Acetaminofen/toxicidade , Ibuprofeno/toxicidade , Efeitos Tardios da Exposição Pré-Natal/patologia , Motilidade dos Espermatozoides/efeitos dos fármacos , Espermatozoides/patologia , Testículo/patologia , Analgésicos não Narcóticos/toxicidade , Animais , Anti-Inflamatórios não Esteroides/toxicidade , Embrião de Mamíferos/efeitos dos fármacos , Embrião de Mamíferos/patologia , Células Germinativas Embrionárias/efeitos dos fármacos , Células Germinativas Embrionárias/patologia , Feminino , Masculino , Exposição Materna/efeitos adversos , Camundongos , Gravidez , Efeitos Tardios da Exposição Pré-Natal/induzido quimicamente , Reprodução , Espermatozoides/efeitos dos fármacos , Espermatozoides/metabolismo , Testículo/efeitos dos fármacos , Testículo/metabolismo
10.
Clin Chem Lab Med ; 58(8): 1232-1241, 2020 07 28.
Artigo em Inglês | MEDLINE | ID: mdl-32267242

RESUMO

Background All general biochemistry instruments allow the measure of hemolysis index (HI), and suppliers provide an acceptable HI for each assay without consideration of the analyte value or its clinical application. Our first objective was to measure the impact of hemolysis degree on plasma biochemical and immunochemical analytes to determine the maximum allowable HI for each of them using four calculation methods as significant bias in comparison to manufacturer's data. The second objective was to assess whether the maximum allowable HI varied according to the analyte values. Methods Twenty analytes were measured in hemolyzate-treated plasma to determine the HI leading to a significant change compared to baseline value. Analytes were assessed at one (3 analytes), two (5 analytes) and three (12 analytes) values according to their sensitivity to hemolysis and their clinical impact. We used four calculation methods as significant limit from baseline value: the total change limit (TCL), the 10% change (10%Δ), the analytical change limit and the reference change value. Results Allowable HI was significantly different according to the threshold chosen for most analytes and was also dependent on the analyte value for alkaline phosphatase, alanine aminotransferase, aspartate aminotransferase, creatine kinase, iron, haptoglobin and high sensitivity troponin T. No hemolysis interference was observed for albumin, creatinine, C-reactive protein, and procalcitonin even at an HI value of 11 g/L. Conclusions This study highlights that TCL is the most appropriate calculation method to determine allowable HI in practice for biochemical and immunochemical parameters using Cobas 8000© from Roche Diagnostics. In addition, different allowable HI were found according to analyte value leading to optimization of resampling to save time in patient care.


Assuntos
Hemólise , Humanos , Valores de Referência , Reprodutibilidade dos Testes
11.
Scand J Clin Lab Invest ; 80(7): 541-545, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33124916

RESUMO

To determine the analytical performance of Novel VITROS BRAHMS Procalcitonin Immunoassay on VITROS 3600 and correlation with BRAHMS PCT sensitive KRYPTOR reference method. Analytical performances including imprecision studies, linearity, limit of detection (LoD) and determination of hemolysis index were performed for VITROS BRAHMS PCT assay. Imprecision was assessed on plasma pool and internal control with 2 levels. The method comparison was performed using 162 plasma obtained from clinical departments. The total imprecision was acceptable and all CV were <5%. The LoD was in accordance with manufacturer's claims. The equation of linearity in the lower range was found to be y = 1.0014x - 0.0091, with r2 = 1. No interference to hemoglobin up to 11 g/L was observed. Correlation studies showed a good correlation between PCT measurements using VITROS BRAHMS PCT assay against KRYPTOR system including for values lower than 2 µg/L. The novel VITROS BRAHMS PCT assay from OrthoClinical Diagnostics shows analytical performances acceptable for clinical use. In addition, the concordance with KRYPTOR method was fine at all clinical cut-offs.


Assuntos
Imunoensaio/métodos , Pró-Calcitonina/sangue , Humanos , Imunoensaio/instrumentação , Limite de Detecção , Análise de Regressão
12.
Anal Chem ; 91(24): 15500-15508, 2019 12 17.
Artigo em Inglês | MEDLINE | ID: mdl-31730336

RESUMO

The extraction of accurate physiological parameters from clinical samples provides a unique perspective to understand disease etiology and evolution, including under therapy. We introduce a new methodologic framework to map patient proteome dynamics in vivo, either proteome-wide or in large targeted panels. We applied it to ventricular cerebrospinal fluid (CSF) and could determine the turnover parameters of almost 200 proteins, whereas a handful were known previously. We covered a large number of neuron biology- and immune system-related proteins, including many biomarkers and drug targets. This first large data set unraveled a significant relationship between turnover and protein origin that relates to our ability to investigate organ physiology with protein-labeling strategy specifics. Our data constitute the first draft of CSF proteome dynamics as well as a repertoire of peptides for the community to design new analyses. The disclosed methods apply to other fluids or tissues provided sequential sample collection can be performed. We show that the proposed mathematical modeling applies to other analytical methods in the field.


Assuntos
Líquido Cefalorraquidiano/química , Proteínas/química , Biomarcadores/líquido cefalorraquidiano , Humanos , Proteínas/metabolismo , Proteoma/análise , Proteômica/métodos , Hemorragia Subaracnóidea/líquido cefalorraquidiano
13.
J Transl Med ; 16(1): 296, 2018 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-30359283

RESUMO

BACKGROUND: Subclinical mastitis (SCM) is relatively common in lactating women and may be associated with HIV shedding in breast milk. The potential association between HIV infection and breast milk immunologic factors and immune response to SCM needs to be addressed. METHODS: In this cross-sectional study, SCM (Na/K ratio > 1) was tested in 165 mature breast milk samples collected from 40 HIV-infected women who didn't transmit HIV to their child by breastfeeding and 43 HIV-uninfected women enrolled in an interventional cohort in South-Africa (Vertical Transmission Study). The level of 33 immune markers related to Th1/Th2 related response, inflammation and bacterial exposure were compared in ART-naive HIV-infected versus HIV-uninfected women. The associations between HIV infection and SCM on the concentration of immune factors were tested separately by Wilcoxon rank-sum test and corrected for false discovery rate. To control for potential confounder effects and take into account the clustering of breast milk samples from a single woman, multivariate mixed linear models adjusted on child age at the time of sampling were performed for each immune factor. RESULTS: Subclinical mastitis was detected in 15 (37.5%) HIV-infected women and 10 (23.3%) HIV-uninfected women. In the absence of SCM, the breast milk levels of IP-10 and MIG were higher and IL1-RA lower in HIV-infected women than in HIV-uninfected women (respectively p < 0.001, p = 0.001, p = 0.045). In HIV-uninfected women, SCM was characterized by a robust immune response with higher concentrations of a broad panel of Th1 and inflammatory related immune markers than in samples without SCM. By contrast, in HIV-infected women a limited number of immune markers were increased and lower increases were observed in samples with SCM than without SCM. CONCLUSION: HIV infection in ART-naïve women was associated with elevated breast milk levels of IP-10 and MIG, which areTh1-related cytokines induced by IFN-γ. During SCM, a lower and narrower immune response was observed in HIV-infected than HIV-uninfected women, suggesting that HIV infection affects the capacity of the mammary gland to respond to SCM.


Assuntos
Infecções por HIV/complicações , Mastite/complicações , Mastite/imunologia , Adolescente , Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Leite Humano/imunologia , Estatísticas não Paramétricas , Adulto Jovem
14.
Clin Chem Lab Med ; 56(3): 413-421, 2018 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-28888086

RESUMO

BACKGROUND: Blood specimens are transported from clinical departments to the biochemistry laboratory by hospital courier service, sometimes over long distances. The aim of this study was to assess the stability of common biochemical analytes in venous blood under our routine transport conditions and to evaluate analyte stability after prompt or delayed centrifugation. METHODS: We investigated pre- and postanalytical contributions of 32 biochemical analytes in plasma and serum samples from 10 patients (healthy adults and patients from intensive care units). Differences in analyte concentrations between baseline (T0) and different time intervals (2, 4, 6, 8, 12 and 24 h) following storage after prompt and delayed centrifugation were reported. Evaluation was against the total change limit as described by Oddoze et al. (Oddoze C, Lombard E, Portugal H. Stability study of 81 analytes in human whole blood, in serum and in plasma. Clin Biochem 2012;45:464-9). RESULTS: The majority of analytes were stable with delayed separation up to 12 h, except for potassium, C-peptide, osteocalcin, parathyroid hormone (PTH), bicarbonate and LDH. After prompt centrifugation and storage at 4°C, stability was greatly increased up to 48 h for most analytes. LDH and bicarbonate had the lowest stability after centrifugation; therefore, no reanalysis of these analytes in a centrifuged tube can be allowed. CONCLUSIONS: Knowledge of analyte stability is crucial to interpret biological analysis with confidence. However, centrifugation prior to transport is time consuming, and the transfer of plasma or serum from a primary tube to a secondary tube increases the risk of preanalytical errors. For analytes that are stable in whole blood for 24 h or more, it seems that there is no benefit to centrifuge before transport.


Assuntos
Análise Química do Sangue , Preservação de Sangue , Heparina/sangue , Lítio/sangue , Potássio/sangue , Coleta de Amostras Sanguíneas , Humanos
15.
Pediatr Res ; 81(4): 556-564, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27814344

RESUMO

BACKGROUND: Subclinical mastitis (SCM) is a frequent, but poorly characterized entity that may influence immune development of breastfed infants. Mechanisms driving the emergence of SCM and changes in immunological content of human milk during SCM remain to be explored. In this study, the breast milk environment was to describe during SCM. METHODS: One hundred and ten samples of mature breast milk were collected from 44 healthy, HIV-negative mothers, included in a large infant feeding intervention cohort (ANRS 1271/Vertical Transmission Study). Immune markers related to inflammatory/anti-inflammatory balances and secreted in response to bacterial exposure were explored in SCM breast milk samples (Na/K ratio > 1) and compared to non-SCM controls. RESULTS: SCM was observed in 23% of women (95% confidence interval (CI): 21-24) and associated with higher levels of inflammatory markers (ß2 microgobulin, PS100A9, TNF-α, IL-6, IL-8, IL-17, and RANTES) and Th1-related cytokines (IL-2R, IL-12p40/70, IFN-α, IFN-γ, CXCL-9, andIP-10). High levels of factors secreted in response to bacteria and lipopolysaccharide (LPS) exposure were observed in SCM breast milk samples (MIP-1α, MIP-1ß, LPS binding protein, α-defensins, and antileukoproteinase 1). CONCLUSION: SCM is associated with important changes in breast milk microenvironment, with a proinflammatory/Th1-cytokine predominant profile. During SCM, cytokine imbalances in breast milk may have a notable influence on mucosal immune system of the infant early in life.


Assuntos
Inflamação/imunologia , Mastite/imunologia , Leite Humano/química , Adolescente , Adulto , Aleitamento Materno , Estudos de Coortes , Citocinas/química , Feminino , Humanos , Inflamação/complicações , Lactação , Lipopolissacarídeos/química , Mastite/complicações , Mucosa/imunologia , Potássio/química , Sensibilidade e Especificidade , Sódio/química , Células Th1/citologia , Células Th2/citologia , Adulto Jovem
18.
Clin Lab ; 63(4): 851-854, 2017 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-28397478

RESUMO

BACKGROUND: We report the analytical and clinical performances of the Alere Triage Cardiac3© Panel on the Triage MeterPro© instrument, comparing concordance with hs-cTnT results from central laboratory above the respective 99th percentiles and determining the clinical sensitivity within the framework of AMI. METHODS: The concordance was obtained with these two methods among unselected patients admitted to both the emergency and cardiology departments. RESULTS: The LoD of the assay is 0.010 µg/L. At 99th percentile (0.02 µg/L) the CV was found to be 18%, below the clinically acceptable cutoff of 20%. In the overall population, ROC AUC was not significantly different between the central laboratory assay and POC assay, with 0.952 (95% CI, 0.918 - 0.952) for hs-cTnT concentrations at presentation and 0.953 (95% CI, 0.912 - 0.953) for cTnI. Sensitivity and specificity of hs-cTnT vs. cTnI for AMI (n = 32) were 97% and 78% vs. 91% and 86%, respectively. Our results indicated 90.4% concordance between the two methods using the 99th percentile specific for each assay. The Kappa coefficient was higher than 0.75, and the strength of agreement could be considered to be good. CONCLUSIONS: The results of cTnI Alere assays provide similar clinical classification of patients, particularly for the AMI group as compared to the central laboratory hs-cTnT assay and could be suitable for clinical in accordance with the recommendations of Global Task Force guidelines.


Assuntos
Sistemas Automatizados de Assistência Junto ao Leito , Biomarcadores , Humanos , Infarto do Miocárdio , Triagem , Troponina I , Troponina T
19.
Ther Drug Monit ; 38(6): 808-812, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27494947

RESUMO

BACKGROUND: Many patients are maintained at the lower end of the tacrolimus (TAC) reference range (3-7 ng/mL), requiring the use of analytical methods displaying a very low limit of quantification for their follow-up. Therefore, the new Dimension TAC, based on affinity chrome-mediated immunoassay technology, was evaluated on the Dimension EXL Integrated Chemistry System (Siemens Healthcare Diagnostics Inc). The aims of this study were (1) to evaluate the analytical performances with special emphasis on sensibility at low levels of TAC, (2) to compare the results with an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC/MS/MS) method. METHODS: Analytical performance (imprecision, linearity, limit of detection, and limit of quantification) was evaluated. Comparison to UPLC/MS/MS was performed on 106 whole blood samples from 88 transplant recipients using regression analysis and Bland-Altman plot analysis. RESULTS: Repeatability and within-laboratory coefficients of variation were <6% at mean TAC control levels of 3.7, 11.7, and 19.2 ng/mL. Linearity was confirmed between 1.0 and 22 ng/mL. Passing-Bablok regression analysis of Siemens TAC assay in comparison with UPLC/MS/MS values displayed a slope of 1.09 and an intercept of -0.42. Using Bland-Altman analysis, the mean bias was 0.27 ng/mL with 1.96 SD limits of -2.14 and 2.67 ng/mL. CONCLUSIONS: The new Dimension TAC immunoassay on the EXL analyzer demonstrated reliable and reproducible performances allowing routine monitoring in transplant patients, even at TAC concentrations at the lower end of the therapeutic range.


Assuntos
Imunossupressores/sangue , Tacrolimo/sangue , Bioensaio/métodos , Cromatografia Líquida de Alta Pressão/métodos , Monitoramento de Medicamentos/métodos , Feminino , Humanos , Imunoensaio/métodos , Limite de Detecção , Masculino , Pessoa de Meia-Idade , Espectrometria de Massas em Tandem/métodos
20.
Clin Chem Lab Med ; 54(4): 673-82, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26457775

RESUMO

BACKGROUND: New highly sensitive (hs) assays have challenged the interpretation of cardiac troponins (cTn). The present study was designed to evaluate simultaneously conventional cTnT and cTnI together with their corresponding highly sensitive determinations in stable hemodialysis (HD) patients. Ability of cTn to stratify HD patient risk was assessed. METHODS: A total of 224 stable HD patients was included in this observational study. cTnT and hs-cTnT were measured using Roche cTnT/hs-cTnT assays based on a Cobas e601® analyzer. cTnI and hs-cTnI were measured using Beckman AccuTnI/hs-TnI IUO assays on Access II system. Patients were followed up prospectively during 9 years. Relationship between cTn level and mortality was assessed through Cox survival analysis. RESULTS: The median cTnT and cTnI concentrations were 38.5 ng/L (IQR, 18.8-76) and 10 ng/L (IQR, 10-20), respectively. The median hs-cTnT and hs-cTnI concentrations were 62.5 ng/L (IQR, 38.8-96.3) and 13.9 ng/L (IQR, 8.4-23.6), respectively. The prevalence of values above the 99th percentile was significantly more marked with cTnT (85.3 and 97.8% for conventional and hs cTnT, respectively) than with cTnI (7.6 and 67.4% for conventional and hs cTnI, respectively). During the follow-up, 167 patients died, mainly from cardiac cause (n=77). The optimized cut-off values, determined by bootstrap method, predicting mortality were 38, 69, 20 and 11 ng/L for cTnT, hs-cTnT, cTnI and hs-cTnI, respectively. After full adjustment, elevated plasma concentrations of all troponin were significant predictors of mortality. CONCLUSIONS: A large proportion of patients free of acute coronary syndrome (ACS) has hs-cTn I or T higher than the 99th percentile which could be seen as a limiting factor for ACS screening. However, all generation and type of troponin assays could be reliable indicators of prognosis risk in HD patients.


Assuntos
Análise Química do Sangue , Doenças Cardiovasculares/sangue , Doenças Cardiovasculares/diagnóstico , Diálise Renal , Troponina I/sangue , Troponina T/sangue , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA