RESUMO
BACKGROUND: Dynamic arterial elastance (Eadyn) has been proposed as an indicator of vascular tone that predicts the decrease in arterial pressure in response to changes in norepinephrine (NE). The purpose of this study was to determine whether Eadyn measured by uncalibrated pulse contour analysis (UPCA) can predict a decrease in arterial pressure when the NE dosage is decreased. METHODS: We conducted a prospective study in a university hospital intensive care unit. Patients with vasoplegic syndrome for whom the intensive care physician planned to decrease the NE dosage were included. Haemodynamic and UPCA (VolumeView and FloTrac; Edwards Lifesciences, Irvine, CA, USA) values were obtained before and after decreasing the NE dosage. Responders were defined by a >10% decrease in mean arterial pressure (MAP). RESULTS: Of 35 patients included, 11 (31%) were pressure responders with a median decrease of 13%. Eadyn was correlated to systolic arterial pressure (SAP) (r=0.255; P=0.033), diastolic arterial pressure (r=0.271; P=0.024), MAP (r=0.310; P=0.009), heart rate (r=0.543; P=0.0001), and transthoracic echography cardiac output (r=0.264; P=0.024). Baseline Eadyn was correlated with MAP changes (r=0.394; P=0.019) and SAP changes (r=0.431; P=0.009). Eadyn predicted the decrease in arterial pressure with an area under the receiver-operating-characteristic curve of 0.84 (95% confidence interval: 0.70-0.97). The best cut-off was 0.90. CONCLUSIONS: The present study confirms the ability of Eadyn measured by UPCA to predict an arterial pressure response to a decrease in NE. Eadyn may constitute an easy-to-use functional approach to arterial tone assessment regardless of the monitor used to measure its determinant. CLINICAL TRIAL REGISTRATION: DRCIT95.
Assuntos
Pressão Arterial/efeitos dos fármacos , Norepinefrina/administração & dosagem , Análise de Onda de Pulso/métodos , Vasoconstritores/administração & dosagem , Vasoplegia/tratamento farmacológico , Idoso , Idoso de 80 Anos ou mais , Pressão Arterial/fisiologia , Cuidados Críticos/métodos , Relação Dose-Resposta a Droga , Elasticidade/efeitos dos fármacos , Elasticidade/fisiologia , Feminino , Hemodinâmica/efeitos dos fármacos , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Norepinefrina/farmacologia , Estudos Prospectivos , Vasoconstritores/farmacologia , Vasoplegia/fisiopatologiaRESUMO
BACKGROUND: The objective of this study was to test whether non-invasive assessment of respiratory stroke volume variation (ΔrespSV) by oesophageal Doppler monitoring (ODM) can predict fluid responsiveness during surgery in a mixed population. The predictive value of ΔrespSV was evaluated using a grey zone approach. METHODS: Ninety patients monitored using ODM who required i.v. fluids to expand their circulating volume during surgery under general anaesthesia were studied. Patients with a preoperative arrhythmia, right ventricular failure, frequent ectopic beats, or breathing spontaneously were excluded. Haemodynamic variables and oesophageal Doppler indices [peak velocity (PV), stroke volume (SV), corrected flow time (FTc), cardiac output (CO), ΔrespSV, and respiratory variation of PV (ΔrespPV)] were measured before and after fluid expansion. Responders were defined by a >15% increase in SV after infusion of 500 ml crystalloid solution. RESULTS: SV was increased by ≥15% after 500 ml crystalloid infusion in 53 (59%) of the 90 patients. ΔrespSV predicted fluid responsiveness with an area under the receiver-operating characteristic (AUC) curve of 0.91 [95% confidence interval (95% CI): 0.85-0.97, P<0.0001]. The optimal ΔrespSV cut-off was 14.4% (95% CI: 14.3-14.5%). The grey zone approach identified 12 patients (14%) with a range of ΔrespSV values between 14% and 15%. FTc was not predictive of fluid responsiveness (AUC 0.49, 95% CI: 0.37-0.62, P=0.84). CONCLUSIONS: ΔrespSV predicted fluid responsiveness accurately during surgery over a ΔrespSV range between 14% and 15%. In contrast, FTc did not predict fluid responsiveness.