Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Orthod Craniofac Res ; 20(1): 21-29, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28102014

RESUMO

OBJECTIVES: To investigate possible changes and/or device-related impairments in phonetic habits produced by rapid maxillary expansion (RME). MATERIALS AND METHODS: Thirty-five patients scheduled for RME were divided into two groups: Group A (banded two-arm Hyrax) and Group B (banded four-arm Hyrax). Speech samples were collected at six time points, before, during and after RME removal. Acoustical analysis was performed using PRAAT and BioVoice analysis tools. Ten volunteers completed a questionnaire on the acceptability of patient's speech. Maxillary dimensions and palatal volume were measured on dental casts before and after expansion using a digital gauge. RESULTS: Voice analysis showed an increase in the peak frequency of fricative consonants (/s/,/ʃ/) after expansion, whereas there was no change of formant frequencies of palatal consonants (/ɲ/,/ʎ/). Vowel /i/ displayed a lowering of the first formant frequency, and an increase in the second and third formant frequencies. After bonding, Group B showed both a greater reduction in the peak frequency of fricatives and a greater increase in the formant frequencies of palatal consonants than Group A. CONCLUSION: Rapid maxillary expansion causes a slight phonetic change in the acoustical parameters of both consonants and vowels. The two-arm Hyrax caused less speech impairment than the four-arm Hyrax during the treatment.


Assuntos
Técnica de Expansão Palatina , Fonética , Acústica da Fala , Adolescente , Criança , Feminino , Humanos , Masculino
2.
Microvasc Res ; 88: 42-7, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23538315

RESUMO

The presence of dysautonomia in diabetic neuropathy is correlated with impairment of vasomotor activity that drives blood microcirculation. Microcirculation, in turn, plays an important role in thermoregulation. In this work, we investigate the changes between two different physiological conditions of diabetic patients, induced by FREMS application, in the control of skin temperature, using a minimally invasive experiment. Skin is warmed up to a fixed temperature (44 °C) for a few minutes, then the heat source is turned off, letting the skin recover its physiological temperature. Both temperature and local blood flow, the latter measured with laser Doppler, are monitored during the experiment. A simple model of the cooling phase is used to evaluate the time constants involved in the process. Results indicate that significant differences exist in the model parameters between the two conditions.


Assuntos
Velocidade do Fluxo Sanguíneo , Regulação da Temperatura Corporal/fisiologia , Diabetes Mellitus Tipo 2/sangue , Neuropatias Diabéticas/sangue , Microcirculação/fisiologia , Fluxo Sanguíneo Regional/fisiologia , Idoso , Feminino , Hemodinâmica , Humanos , Fluxometria por Laser-Doppler , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Distribuição Normal , Temperatura Cutânea , Temperatura , Fatores de Tempo
3.
Minerva Cardioangiol ; 60(3): 267-73, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22653042

RESUMO

AIM: Same-day discharge (SDD) in the setting of catheter ablation (CA) is not widely applied. We present our experience concerning SDD in a selected population of patients who underwent CA; the outcome was evaluated in terms of feasibility and safety. METHODS: 401 CA procedures were performed at our institution between January 2008 and December 2009 in 379 patients (65±16 years, 221 men). 336 CA procedures (84%) were considered eligible for SDD, after the exclusion of ventricular arrhythmias, atrial fibrillation, atypical atrial flutter, AV node ablation as well as procedures involving an arterial or transseptal access. Subsequently, a number of clinical and organizational exclusion criteria were applied. RESULTS: 223 patients were actually discharged on the same day of CA (56% of 401 overall CA procedures): 114 atrial flutter (AFL) and 109 supraventricular tachycardia. Many patients were excluded before CA due to a limited availability of the day-hospital facility; this occurred more frequently in the year 2008 than 2009 (45 vs. 2, P=0.0001); in the year 2009 the rate of total CA procedures which underwent SDD was of 68%. Overall, three groin hematomas occurred, all in patients ablated for AFL. Two of them were recognized during the postablation CONCLUSION: SDD can be safely performed in most patients undergoing CA for routine arrhythmias. This may result in a significant impact on daily practice in terms of both organizational improvement and subjective benefit for the patients.


Assuntos
Procedimentos Cirúrgicos Ambulatórios , Arritmias Cardíacas/cirurgia , Ablação por Cateter , Alta do Paciente , Idoso , Feminino , Humanos , Masculino
4.
J Voice ; 31(1): 111.e1-111.e7, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27068549

RESUMO

Smartphone technology provides new opportunities for recording standardized voice samples of patients and sending the files by e-mail to the voice laboratory. This drastically improves the collection of baseline data, as used in research on efficiency of voice treatments. However, the basic requirement is the suitability of smartphones for recording and digitizing pathologic voices (mainly characterized by period perturbations and noise) without significant distortion. In this experiment, two smartphones (a very inexpensive one and a high-level one) were tested and compared with direct microphone recordings in a soundproof room. The voice stimuli consisted in synthesized deviant voice samples (median of fundamental frequency: 120 and 200 Hz) with three levels of jitter and three levels of added noise. All voice samples were analyzed using PRAAT software. The results show high correlations between jitter, shimmer, and noise-to-harmonics ratio measured on the recordings via both smartphones, the microphone, and measured directly on the sound files from the synthesizer. Smartphones thus appear adequate for reliable recording and digitizing of pathologic voices.


Assuntos
Acústica/instrumentação , Pesquisa Biomédica/instrumentação , Aplicativos Móveis , Smartphone , Acústica da Fala , Medida da Produção da Fala/instrumentação , Patologia da Fala e Linguagem/instrumentação , Distúrbios da Voz/diagnóstico , Qualidade da Voz , Humanos , Teste de Materiais , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Espectrografia do Som , Distúrbios da Voz/fisiopatologia , Distúrbios da Voz/terapia
5.
Am J Cardiol ; 82(5): 676-9, A8, 1998 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-9732902

RESUMO

In a group of 20 patients implanted with a single-lead VDD pacing system, a wide interindividual variability was found in P-wave amplitude changes occurring under dynamic conditions, even though they were of minor clinical relevance because constant atrial tracking was maintained.


Assuntos
Eletrocardiografia/instrumentação , Bloqueio Cardíaco/terapia , Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Teste de Esforço , Feminino , Seguimentos , Bloqueio Cardíaco/fisiopatologia , Humanos , Masculino , Postura/fisiologia , Respiração/fisiologia
6.
Ann Thorac Surg ; 71(5 Suppl): S261-4, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11388200

RESUMO

BACKGROUND: We previously showed that the risk of reoperation for structural degeneration of bioprostheses was higher in cases involving patients older than 65 years (p = 0.003) and double-valve replacement (p = 0.02). The purpose of this study was to compare late outcome of mitral-aortic valve replacement using bioprostheses or mechanical valves. METHODS: The bioprosthesis group included all mainland France residents (n = 48) between 55 and 65 years old operated on between 1980 and 1995 for mitral-aortic valve replacement using bioprostheses. The mechanical valve group was obtained by matching each of these patients with a patient operated on using mechanical valves at approximately the same time during the study. RESULTS: In the bioprosthesis group, 10-year survival was 45%+/-8% versus 62%+/-7% in the mechanical valve group (not significant). The linearized reoperation rate was 6.8 per patient-year versus 1.1 per patient-year (p = 0.001), and the linearized reoperative mortality rate was 1.8 per patient-year and 0.7 per patient-year (not significant), respectively. CONCLUSIONS: The reoperative mortality risk after mitral-aortic valve replacement using two bioprostheses does not significantly decrease overall survival after age 65 years.


Assuntos
Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Valva Mitral/cirurgia , Idoso , Análise de Falha de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Reoperação , Análise de Sobrevida
7.
Clin Cardiol ; 23(9): 678-80, 2000 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11016018

RESUMO

BACKGROUND: Single-lead VDD pacing systems are an alternative to conventional DDD pacemakers in patients with atrioventricular (AV) block and normal sinus function. HYPOTHESIS: The aim of this study was to assess changes of P-wave amplitude occurring in dynamic conditions in two groups of patients with a single-lead VDD and with a DDD pacing system, respectively. METHODS: Twenty-eight patients with second- or third-degree AV block and normal sinus function were enrolled prospectively into the study. Seventeen patients were implanted with a single-lead VDD pacing system and 11 with a DDD pacemaker. Patients were evaluated at 3 months (all patients) and at 6 months (26 patients) at supine and in dynamic conditions (postural changes, hyperventilation, and during exercise). RESULTS: Mean P-wave values at supine were 1.92 +/- 1.10 mV at 3 months and 1.76 +/- 1.01 mV at 6 months for VDD systems, and 4.63 +/- 2.18 mV at 3 months and 4.58 +/- 2.80 mV at 6 months for DDD pacemakers. In dynamic conditions, P-wave amplitude changes compared with supine condition ranged between -74 and +226% in VDD, and between -53 and +138% in DDD; however P-wave amplitudes showed no significant changes compared with baseline. Moreover, changes in atrial signal amplitudes did not occur randomly, and in both systems P-wave amplitudes remained significantly correlated with supine values. CONCLUSIONS: A wide range of P-wave amplitude variations occurs in different postural conditions or during exercise, both with single-lead VDD and DDD pacing systems. However, with appropriate programming of atrial sensitivity based on supine values, constant atrial tracking can be maintained.


Assuntos
Estimulação Cardíaca Artificial/métodos , Bloqueio Cardíaco/terapia , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Eletrodos Implantados , Teste de Esforço , Humanos , Pessoa de Meia-Idade , Postura , Estudos Prospectivos , Respiração
8.
Transplant Proc ; 36(10): 3173-4, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15686722

RESUMO

A close association between human herpesvirus-8 (HHV-8) and Kaposi's sarcoma (KS) has been shown in transplant recipients, but donor-to-recipient transmission of HHV-8 is uncommon. Herein we report a case of a heart transplant recipient who had a fatal visceral KS in association with HHV-8 seroconversion at 18 months after transplantation with a donor having positive serology discovered after transplantation.


Assuntos
Transplante de Coração/efeitos adversos , Herpesvirus Humano 8/isolamento & purificação , Complicações Pós-Operatórias/virologia , Sarcoma de Kaposi/virologia , Adulto , Evolução Fatal , Feminino , Humanos , Imunossupressores/uso terapêutico
9.
Eur Psychiatry ; 13(1): 46-51, 1998.
Artigo em Inglês | MEDLINE | ID: mdl-19698598

RESUMO

Authors recently have suggested that family enrneshment is not synonymous with high levels of closeness or cohesion. A model proposed by Green and Werner clarifies the cohesion-enmeshment domain by distinguishing between closeness-caregiving and intrusiveness as separate relationship processes. This paper examines the cross-cultural applicability of this perspective through a study of 61 married couples in France. The French version of the California Inventory for Family Assessment (CIFA), a self-report measure designed to assess clinically relevant marital dimensions, was employed. In general, spouses' reports of their marital process demonstrated high internal consistency reliabilities. Factor analysis showed meaningful factor structures distinguishing closeness-caregiving and intrusiveness, as predicted, as well as openness of communication. Significant correlations were obtained between CIFA scales and scores on the Marital Adjustment Test. These results are similar for French and American couples. Research implications for studying relationships among French-speaking couples are underlined.

10.
Arch Mal Coeur Vaiss ; 68(4): 363-8, 1975 Apr.
Artigo em Francês | MEDLINE | ID: mdl-816291

RESUMO

A great number of congenital heart diseases are now amenable to treatment before school age. A homogeneous experience of 158 cases operated upon made it possible to make the follow remarks:--The operative mortality before the age of 1 year remains high, in view of the difficulties of ressuscitation, but mainly because of the severity of the heart disease to treat. --Between the ages of 1 and 5 years, the risk decreased with experience, and for the heart diseases most frequently encountered, lethality fell to 2.8% for the last 4 years. One may thus accept to perform, not only necessity operations, but principle operations before school age. The schematic indications in relation with each heart disease were analysed.


Assuntos
Procedimentos Cirúrgicos Cardíacos/mortalidade , Pré-Escolar , Circulação Extracorpórea , Comunicação Interatrial/cirurgia , Comunicação Interventricular/cirurgia , Humanos , Lactente , Recém-Nascido , Complicações Pós-Operatórias/mortalidade , Tetralogia de Fallot/cirurgia , Transposição dos Grandes Vasos/cirurgia
11.
Ann Chir ; 43(8): 591-5, 1989.
Artigo em Francês | MEDLINE | ID: mdl-2589792

RESUMO

A heterotopic heart transplantation was performed on a patient placed on circulatory assistance with a Biomedicus pump for ten days using a heart taken from a donor with situs inversus. In relation to this case, the authors describe the technical procedures allowing transplantation of a heart obtained from a donor with situs inversus into a heterotopic position and an orthotopic position or a normal heart in a recipient with situs inversus. Lastly, in the case of complex cardiac malformations with preservation of the lungs, they present the procedures allowing heart transplantation in cases of situs incertus, anomalies of venous return and transposition of the great vessels.


Assuntos
Transplante de Coração/métodos , Situs Inversus , Adulto , Anastomose Cirúrgica , Circulação Assistida , Cardiopatias Congênitas/cirurgia , Humanos , Masculino , Transplante Heterotópico
12.
Ann Cardiol Angeiol (Paris) ; 32(6): 387-92, 1983 Oct.
Artigo em Francês | MEDLINE | ID: mdl-6421221

RESUMO

Based on data from the literature and their own experience, the authors study the long-term clinical course of patients with interatrial communications (IAC), coarctation of the aorta (CAo) and tetralogy of Fallot (TF) who have been operated. According to data from the literature and 50 cases which were reviewed an average of 11 years after the operation, operated cases of IAC are at risk of developing arrhythmias or conduction disturbances, especially if the operation was performed after the age of 20, in cases with cardiomegaly, with a mean pulmonary artery pressure of more than 20 mmHg and a pulmonary flow/systemic flow ratio due to the shunt greater than 1.5. Surgery for CAo carries a risk of long-term residual hypertension (HT). According to the majority of authors and a study of 55 cases. HT is present in 3 to 6% of cases operated between the ages of 1 and 10 years. This percentage is much higher for the older age groups. The increase in blood pressure on effort and the demonstration of a gradient between the upper limb and the lower limb are the methods of detecting post-operative hypertension and residual stenosis. Cardiac failure and coronary occlusion can occur in the cases which were operated late. Following complete correction of TF, severe ventricular arrhythmias can arise in the long term. From a study of 59 patients at least 3 years after the operation, the authors outline the elements which favour the development of these arrhythmias. The cases at highest risk are those which were operated after the age of 2 years with significant residual lesions, cardiomegaly and ventricular extrasystoles on the resting trace.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Cardiopatias Congênitas/cirurgia , Adolescente , Adulto , Coartação Aórtica/cirurgia , Criança , Pré-Escolar , Seguimentos , Cardiopatias/etiologia , Comunicação Interatrial/cirurgia , Humanos , Lactente , Assistência de Longa Duração , Complicações Pós-Operatórias , Tetralogia de Fallot/cirurgia
13.
Ann Cardiol Angeiol (Paris) ; 38(10): 657-9, 1989 Dec 30.
Artigo em Francês | MEDLINE | ID: mdl-2698118

RESUMO

The authors report one case of torsade de pointe which occurred immediately after fast intravenous injection of a 1-gram dose of erythromycin lactobionate in a female patient who had undergone surgical replacement of the mitral and triscuspid valves 24 hours before. The responsibility of erythromycin was strongly suggested by the clinical data (syncope), electrocardiographic findings (electrocardiogram typical of torsade de pointe, slow rhythm and lengthened QT interval in the basal ECG) and the chronology of the sequence of intravenous injection of the antibiotic and the rhythm disorder. A literature search revealed six similar cases. Its seems that the arrythmogenic property of this drug is related to abnormally elevated serum levels following rapid administration.


Assuntos
Eritromicina/análogos & derivados , Taquicardia/induzido quimicamente , Eritromicina/administração & dosagem , Eritromicina/efeitos adversos , Feminino , Humanos , Injeções Intravenosas/instrumentação , Injeções a Jato , Pessoa de Meia-Idade
14.
Presse Med ; 21(41): 2003-4, 1992 Dec 02.
Artigo em Francês | MEDLINE | ID: mdl-1294965

RESUMO

In conjunction with biopsy and Doppler studies, we analysed by high resolution proton NMR spectroscopy the blood plasma of 22 heart transplant recipients. There was a significant variation in the glycosylated residues of proteins with the development of acute cardiac rejection. A more extensive study is underway to assess the sensitivity and specificity of this approach for the early diagnosis of acute cardiac rejection.


Assuntos
Acetilglucosamina/sangue , Rejeição de Enxerto/diagnóstico , Transplante de Coração/efeitos adversos , Espectroscopia de Ressonância Magnética , Ácidos Siálicos/sangue , Rejeição de Enxerto/sangue , Rejeição de Enxerto/etiologia , Humanos
15.
Presse Med ; 20(24): 1109-12, 1991 Jun 22.
Artigo em Francês | MEDLINE | ID: mdl-1830143

RESUMO

Between 1980 and 1989, 8 patients (5 men, 3 women; mean age 30 years) were operated upon in our department of right-sided infective endocarditis. Six patients were heroin addicts and among these 3 were HIV positive and 2 had confirmed AIDS. The most frequently encountered microorganisms (6 cases) were staphylococci. It was decided to operate because of persistent infection and haemodynamic deterioration. The infection involved the pulmonary valve in only 1 of the 8 patients. Surgery was performed during the acute phase in 5 patients and was conservative in 6 patients, consisting of excision of the vegetations or valvulectomy combined or not with valvuloplasty. A high mortality rate (3/8 cases) was observed only among patients operated upon in the acute phase. This may be due to the underlying immunodeficiency and poor haemodynamic state of these patients. Among survivors, the long-term results were excellent, with no recurrent endocarditis and no death, and with only one subsequent operation, 4 years after the first one, for residual tricuspic valve regurgitation. This study shows that patients with right-sided infective endocarditis should be operated upon outside the acute phase of the disease and as soon as complications appear, and that surgery should preferably be conservative.


Assuntos
Síndrome da Imunodeficiência Adquirida/complicações , Endocardite Bacteriana/cirurgia , Soropositividade para HIV/complicações , Infecções Estafilocócicas/cirurgia , Infecções Estreptocócicas/cirurgia , Adulto , Antibacterianos/uso terapêutico , Bioprótese , Endocardite Bacteriana/tratamento farmacológico , Endocardite Bacteriana/etiologia , Feminino , Dependência de Heroína , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios , Infecções Estafilocócicas/tratamento farmacológico , Infecções Estafilocócicas/etiologia , Staphylococcus aureus/isolamento & purificação , Infecções Estreptocócicas/tratamento farmacológico , Infecções Estreptocócicas/etiologia
16.
J Mech Behav Biomed Mater ; 20: 338-46, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23517774

RESUMO

Properties of elasticity, hardness and viscosity are determined for the study of the visco-elastoplastic behavior of bones. The mechanical properties are compared in two upright sections of the bone due to their anisotropy. Besides, influence of hydration treatments leading to structural modifications of collagen and ground substance contents of bones on the mechanical properties is studied on a femoral cortical bovine bone. The treatments applied to the bone are used by forensic anthropologists to remove the soft tissue and modifying the hydration degree coupled to the collagen content. From instrumented indentation experiments, the hardness is characterized by the macrohardness and a hardness length-scale factor stating the hardness-load dependence. The elastic modulus results from the application of the methodology of Oliver and Pharr (1992). The coefficient of viscosity is deduced from a rheological model representing the indenter time-displacement observed under the application of a constant load. As a result, all the mechanical properties are found to be lower in the transverse section in an extent depending on the hydration treatment, i.e. the different values are located between 5% and 25% for the hardness around 0.5GPa, between 25% and 40% for the elastic modulus around 20GPa and between 2% and 35% for the coefficient of viscosity around 60GPa.s. Unexpectedly, the elastic modulus to coefficient of viscosity ratio is found to be independent on the hydration treatment.


Assuntos
Tecido Conjuntivo/química , Fêmur/química , Fêmur/fisiologia , Testes de Dureza/métodos , Preservação de Órgãos/métodos , Água/química , Animais , Bovinos , Módulo de Elasticidade/fisiologia , Dureza/fisiologia , Técnicas In Vitro , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Viscosidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA