1.
J Vasc Interv Radiol ; 34(8): 1291-1302.e1, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36977432

RESUMO

The discovery of increasing numbers of actionable molecular and gene targets for cancer treatment has driven the demand for tissue sampling for next-generation sequencing (NGS). Requirements for sequencing can be very specific, and inadequate sampling leads to delays in management and decision making. It is important that interventional radiologists are aware of NGS technologies and their common applications and be cognizant of the factors that contribute to successful sample sequencing. This review summarizes the fundamentals of cancer tissue collection and processing for NGS. It elaborates on sequencing technologies and their applications with the aim of providing readers with a working understanding that can enhance their clinical practice. It then describes imaging, tumor, biopsy, and sample collection factors that improve the chances of NGS success. Finally, it discusses future practice, highlighting the problem of undersampling in both clinical and research settings and the opportunities within interventional radiology to address this.


Assuntos
Neoplasias , Humanos , Neoplasias/genética , Biópsia , Sequenciamento de Nucleotídeos em Larga Escala/métodos
2.
J Vasc Interv Radiol ; 32(7): 1068-1074.e1, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33811996

RESUMO

PURPOSE: To systematically investigate artifacts produced by biopsy and ablation needles imaged at various trajectories with respect to the static magnetic field (B0). MATERIALS AND METHODS: An acrylic phantom was scanned using a rapid balanced fast field echo sequence with 3.0-T magnetic resonance imaging. A 15-gauge microwave needle, a 17-gauge cryoneedle, and an 18-gauge coaxial biopsy needle were imaged in sagittal and axial planes, in 7 different orientations to B0 (0°, 15°, 30°, 45°, 60°, 75°, and 90°). For 4 angles (15°, 30°, 60°, and 75°), images were acquired with the slice orientation aligned to the needle angulation, resulting in the frequency encoding direction being parallel to the needle's long axis for the sagittal slice and perpendicular to the needle angulation for the axial acquisition. The artifact length at the needle tip and maximum artifact width were recorded. RESULTS: No significant difference was noted in mean artifact length for the cryoneedle (13 mm; 95% confidence interval [CI], 7-19) and coaxial biopsy needle (8 mm; 95% CI, 5-10; P = .08). The mean artifact length was significantly smaller for the microwave ablation needle (1 mm; 95% CI, 0-2; P < .05). The mean artifact width was highest for the coaxial needle (17 mm; 95% CI, 14-19) and significantly higher than the cryoneedle (12 mm; 95% CI, 10-15; P = .024) and microwave ablation needle (8 mm; 95% CI, 6-10; P < .01). The needle tip artifact was significantly smaller when the slice orientation was aligned to the needle angulation for the coaxial and cryoablation needles (P < .01). CONCLUSIONS: Needle tip artifact length and width increase with increasing angulation to the static field. At large angles (>15°), the needle tip position can be predicted better from images acquired when the slice orientation is aligned to the needle's angulation.


Assuntos
Artefatos , Agulhas , Biópsia por Agulha , Humanos , Imageamento por Ressonância Magnética , Imagens de Fantasmas
3.
AJR Am J Roentgenol ; 215(1): 242-247, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32286877

RESUMO

OBJECTIVE. The purpose of this study was to evaluate the immediate and 3- and 5-year outcomes of patients with clinical stage T1 (cT1) biopsy-proven renal cell carcinoma (RCC) treated by image-guided percutaneous cryoablation at a regional interventional oncology center. MATERIALS AND METHODS. A prospectively maintained local interventional radiology database identified patients with cT1 RCC lesions that were treated by percutaneous cryoablation. Technical success, procedural complications (graded using the Clavien-Dindo classification system), and the residual unablated tumor rate were collated. Local tumor progression-free survival was estimated using Kaplan-Meier estimates. RESULTS. A total of 180 patients with 185 separate cT1 RCC lesions were identified. Mean patient age was 68.4 years (range, 34.1-88.9 years) and 52 patients (28.9%) were women. There were 168 (90.8%) and 17 (9.2%) cT1a and cT1b lesions, respectively, with a mean lesion size of 28.5 mm (range, 11-58 mm). Technical success was achieved in 183 of 185 (98.9%) patients. The major complication rate (Clavien-Dindo classification ≥ grade III) was 2.2% (four out of 185). Residual unablated tumor on the first follow-up scan was identified in four of 183 tumors (2.2%). Estimated local tumor progression-free survival at 3 and 5 years was 98.3% and 94.9%, respectively. No distant metastases or deaths attributable to RCC occurred. Mean estimated glomerular filtration rate (eGFR) before the procedure was 72.4 ± 18.5 (SD) mL/min/1.73 m2 and this was not statistically significantly different after the procedure (69.7 ± 18.8 mL/min/1.73 m2), at 1 year (70.7 ± 16.4 mL/min/1.73 m2), or at 2 years (69.8 ± 18.9 mL/min/1.73 m2) (p > 0.05). CONCLUSION. These data add to the accumulating evidence that image-guided cryoablation is an efficacious treatment for selected cT1 RCC with a low complication rate and ro bust 3- and 5-year outcomes.


Assuntos
Carcinoma de Células Renais/patologia , Carcinoma de Células Renais/cirurgia , Criocirurgia/métodos , Neoplasias Renais/cirurgia , Radiografia Intervencionista , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Taxa de Filtração Glomerular , Humanos , Estimativa de Kaplan-Meier , Neoplasias Renais/patologia , Londres , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Complicações Pós-Operatórias/classificação , Estudos Retrospectivos
4.
Br J Cancer ; 120(8): 779-790, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30911090

RESUMO

Imaging has an essential role in the planning and delivery of radiotherapy. Recent advances in imaging have led to the development of advanced radiotherapy techniques-including image-guided radiotherapy, intensity-modulated radiotherapy, stereotactic body radiotherapy and proton beam therapy. The optimal use of imaging might enable higher doses of radiation to be delivered to the tumour, while sparing normal surrounding tissues. In this article, we review how the integration of existing and novel forms of computed tomography, magnetic resonance imaging and positron emission tomography have transformed tumour delineation in the radiotherapy planning process, and how these advances have the potential to allow a more individualised approach to the cancer therapy. Recent data suggest that imaging biomarkers that assess underlying tumour heterogeneity can identify areas within a tumour that are at higher risk of radio-resistance, and therefore potentially allow for biologically focussed dose escalation. The rapidly evolving concept of adaptive radiotherapy, including artificial intelligence, requires imaging during treatment to be used to modify radiotherapy on a daily basis. These advances have the potential to improve clinical outcomes and reduce radiation-related long-term toxicities. We outline how recent technological advances in both imaging and radiotherapy delivery can be combined to shape the future of precision radiation oncology.


Assuntos
Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia , Radioterapia (Especialidade)/tendências , Humanos , Imageamento por Ressonância Magnética/métodos , Neoplasias/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Terapia com Prótons/tendências , Radiocirurgia/tendências , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/tendências , Radioterapia de Intensidade Modulada/tendências
5.
J Vasc Interv Radiol ; 28(5): 732-739, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27266361

RESUMO

PURPOSE: To compare the size of ablation zones derived from nonperfused ex vivo livers with ablation zones created using an ex vivo perfused porcine liver model. MATERIALS AND METHODS: Six fresh porcine livers were used to evaluate microwave ablation (MWA). Perfused (n = 3) and nonperfused (n = 3) livers were warmed to 37°C by oxygenated, O-positive human blood reconstituted with Ringer solution, using an organ perfusion circuit. During MWA, perfusion was discontinued in the nonperfused group and maintained in the perfused group. After MWA (140 watts × 2 min at 2.45 GHz) with the Acculis MTA System (AngioDynamics, Latham, New York), ablation zones were bisected sagittally. Sections were stained with nicotinamide adenine dinucleotide (NADH) and hematoxylin-eosin to assess viability of cells in ablation and marginal zones. RESULTS: Comparison of 22 MWA zones (9 in perfused group, 13 in nonperfused group) was performed. Ablation zones demonstrated a central "white" and peripheral "red" zone. Cells in the white zone were nonviable with no NADH staining. The red zone showed progressive NADH staining toward the periphery, suggesting incomplete cell death. White and red zones of the perfused group were significantly smaller compared with the nonperfused group (short axis, 17.8 mm ± 2.7 vs 21.1 mm ± 3.2, P = .003; long axis, 40.69 mm ± 3.9 vs 39.63 mm ± 5.2, P = .44; intermediate zone,1.33 mm ± 0.04 vs 2.7 mm ± 0.14, P < .0001; mean ± SD). CONCLUSIONS: MWA algorithms provided by this manufacturer are based on nonperfused organ data, which overestimate ablation zone size. Data from perfused liver models may be required for more accurate dosimetry guidelines.


Assuntos
Técnicas de Ablação , Fígado/irrigação sanguínea , Fígado/cirurgia , Micro-Ondas/uso terapêutico , Animais , Técnicas In Vitro , Fluxometria por Laser-Doppler , Microcirculação , Modelos Animais , Perfusão , Suínos
6.
J Magn Reson Imaging ; 43(5): 1224-9, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26477540

RESUMO

BACKGROUND: To test the principles underpinning equilibrium contrast imaging estimation of tissue extracellular volume (ECV) fraction, using a three-dimensional (3D) engineered tissue model with known cellular and extracellular volumes. METHODS: Six 3D tissue models (tumoroids) consisting of cell cultures within a collagen containing hydrogel were constructed after culture centrifugation and direct measurement of the cell component volume. Measured tumoroid ECV ranged from 0.89 to 1. ECV was calculated after measuring the T1 relaxation time at 3 Tesla using inversion recovery relaxometry (TI 100-1500 ms) within the tumoroids and surrounding medium before and 375 min after spiking the medium with Gadolinium (to achieve a concentration of 1.4 mM/L). Linear regression model prediction of directly measured ECV (ECVm ) by EQ-MRI measured ECV (ECVeq ); and Bland-Altman agreement between measures was assessed. RESULTS: The fractional cellular volume measured by EQ-MRI (ECVeq ) within the tumoroids ranged from 0.821 to 0.963. ECVeq was a good predictor of ECVm (R2 = 0.77, P = 0.02). The regression line Y-axis intercept (when X = 0) was 0.045 ± 0.019 with a slope of 1.28 ± 0.35. Bland-Altman comparison demonstrated 95% limits of agreement between -0.002 and 0.114 with a bias (SD) of 0.056 (0.03). CONCLUSION: This study supports the principles of ECV estimation using equilibrium contrast MRI, but future development of this model may allow validation over a wider, more physiological ECV range and a greater understanding of the effect of tissue extracellular protein burden on ECV.


Assuntos
Meios de Contraste/química , Imageamento Tridimensional/métodos , Engenharia Tecidual/métodos , Linhagem Celular Tumoral , Colágeno/química , Difusão , Gadolínio/química , Células HT29 , Humanos , Hidrogéis/química , Análise dos Mínimos Quadrados , Modelos Lineares , Imageamento por Ressonância Magnética , Miocárdio/patologia , Análise de Regressão , Reprodutibilidade dos Testes
7.
J Vasc Interv Radiol ; 27(4): 474-9, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26944360

RESUMO

PURPOSE: To evaluate the safety and efficacy of percutaneous high-energy microwave ablation (MWA) for the treatment for pulmonary tumors. MATERIALS AND METHODS: A retrospective review was undertaken of 44 patients (21 men, 23 women; median age, 66 y; range, 17-89 y) who underwent 62 sessions of high-energy MWA for 87 pulmonary tumors at a single tertiary referral center between June 2012 and June 2014. Primary tumor origin was sarcoma (n = 23), colorectal (n = 16), lung (n = 2), esophageal (n = 1), breast (n = 1), and bladder (n = 1). Median tumor size was 12 mm (range, 6-45 mm). Technical success was recorded contemporaneously, complication rate at 30 days was recorded prospectively, and technique effectiveness was assessed by longitudinal follow-up CT scan. RESULTS: Primary technical success was achieved in 94% of ablation sessions. The median follow-up interval was 15 months (range, 6.2-29.5 mo) during which time local tumor progression was observed in two of 87 tumors (technique effectiveness 98%). Pneumothorax requiring chest tube insertion occurred in 19%; delayed pneumothorax occurred in four patients. No hemoptysis, infection, or other complications were recorded. CONCLUSIONS: High-energy MWA is safe and effective for the destruction of lung tumors.


Assuntos
Ablação por Cateter/métodos , Neoplasias Pulmonares/cirurgia , Micro-Ondas/uso terapêutico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter/efeitos adversos , Ablação por Cateter/mortalidade , Feminino , Humanos , Estimativa de Kaplan-Meier , Londres , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/mortalidade , Neoplasias Pulmonares/patologia , Masculino , Micro-Ondas/efeitos adversos , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Carga Tumoral , Adulto Jovem
8.
Radiology ; 275(1): 136-43, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25490188

RESUMO

PURPOSE: To prospectively evaluate hepatic extracellular volume (ECV) fraction measurement at equilibrium computed tomographic (CT) imaging compared with both fibrosis quantified with histologic analysis and the enhanced liver fibrosis panel (ELF) in a cohort of patients with chronic hepatitis. MATERIALS AND METHODS: This prospective study was approved by the regional ethics committee. All patients gave fully informed written consent. Forty patients with a clinical indication for liver biopsy were prospectively recruited for liver ECV quantitation at equilibrium CT imaging. Biopsy samples underwent digital image analysis and assessment of collagen content expressed as the collagen-proportionate area (CPA). Spearman correlation was used to evaluate association between ECV, ELF, and CPA. Multiple regression analysis was used to test prediction of CPA by a model that combined ECV and ELF. ECV, ELF score, and CPA were compared with Ishak stage by using the Kruskal-Wallis test. RESULTS: Complete ECV, ELF, and CPA were available in 33 patients. Liver ECV, CPA, and ELF had a median of 0.26 (interquartile range [IQR], 0.24-0.29), 5.0 (IQR, 3.0-15.0), and 9.71 (IQR, 8.14-10.92), respectively. Hepatic ECV demonstrated good association with CPA (r = 0.64; P < .001) and ELF score (r = 0.38; P < .027), with no significant difference in strength of correlation (P = .177). The regression model that combined ELF and ECV achieved good prediction of CPA (R(2) = 0.67; P < .001). Significant variation in ECV and ELF was seen between fibrosis stage groups. CONCLUSION: Hepatic ECV measured with equilibrium CT imaging is associated with biopsy-derived CPA and serum ELF-validated markers of liver fibrosis. This suggests that equilibrium CT imaging can quantify diffuse fibrosis in chronic liver disease.


Assuntos
Meios de Contraste , Iohexol , Cirrose Hepática/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Biópsia , Feminino , Humanos , Cirrose Hepática/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador
9.
Phys Med Biol ; 69(11)2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38697200

RESUMO

Minimally invasive ablation techniques for renal cancer are becoming more popular due to their low complication rate and rapid recovery period. Despite excellent visualisation, one drawback of the use of computed tomography (CT) in these procedures is the requirement for iodine-based contrast agents, which are associated with adverse reactions and require a higher x-ray dose. The purpose of this work is to examine the use of time information to generate synthetic contrast enhanced images at arbitrary points after contrast agent injection from non-contrast CT images acquired during renal cryoablation cases. To achieve this, we propose a new method of conditioning generative adversarial networks with normalised time stamps and demonstrate that the use of a HyperNetwork is feasible for this task, generating images of competitive quality compared to standard generative modelling techniques. We also show that reducing the receptive field can help tackle challenges in interventional CT data, offering significantly better image quality as well as better performance when generating images for a downstream segmentation task. Lastly, we show that all proposed models are robust enough to perform inference on unseen intra-procedural data, while also improving needle artefacts and generalising contrast enhancement to other clinically relevant regions and features.


Assuntos
Meios de Contraste , Processamento de Imagem Assistida por Computador , Tomografia Computadorizada por Raios X , Humanos , Processamento de Imagem Assistida por Computador/métodos , Fatores de Tempo , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/cirurgia
10.
Radiology ; 268(3): 858-64, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23674785

RESUMO

PURPOSE: To investigate equilibrium contrast material-enhanced magnetic resonance (MR) imaging measurement of extracellular volume (ECV) fraction within healthy abdominal tissues and to test the hypotheses that tissue ECV in systemic amyloid light-chain (AL) amyloidosis is greater than in healthy patients and show that this increase correlates with organ amyloid burden. MATERIALS AND METHODS: A local ethics committee approved the study and all patients gave written informed consent. Forty healthy volunteers (18 men, 22 women; median age, 43 years; age range, 24-88 years) and 67 patients with AL amyloidosis (43 men, 24 women; median age, 65 years; age range, 38-81 years) underwent equilibrium MR imaging of the upper abdomen. ECV was measured in the liver, spleen, and paravertebral muscle. Patients with amyloidosis also underwent serum amyloid P (SAP) component scintigraphy so that specific organ involvement by amyloid could be scored. Variation in ECV between tissues was assessed by using a Friedman Test. Tissue ECV in healthy and amyloidosis groups were compared by using a Mann-Whitney U test. Spearman correlation was used to test for an association between the organ SAP score and ECV. RESULTS: ECV measured at equilibrium MR imaging varied significantly between organs in healthy volunteers (χ(2) = 31.0; P < .001). ECV was highest in the spleen (0.34), followed by liver (0.29) and muscle (0.09). ECVs measured within the spleen (0.39; P< .001), liver (0.31; P = .005), and muscle (0.16; P< .001) were significantly higher in patients with amyloidosis than in healthy control subjects. ECV measured in the liver and spleen showed increasing organ amyloid burden assessed at SAP scintigraphy (liver, rs = 0.54; spleen, rs = 0.57). CONCLUSION: Equilibrium MR imaging can be used to define ECV within healthy tissues. ECV is increased in amyloidosis compared with healthy tissues, and this increase correlates with rising tissue amyloid burden.


Assuntos
Amiloidose/patologia , Líquido Extracelular/citologia , Aumento da Imagem/métodos , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Meglumina , Compostos Organometálicos , Baço/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
11.
Radiology ; 269(2): 396-403, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23878282

RESUMO

PURPOSE: To develop and validate equilibrium contrast material-enhanced computed tomography (CT) to measure myocardial extracellular volume (ECV) fraction by using a histologic reference standard and to compare equilibrium CT with equilibrium contrast-enhanced magnetic resonance (MR) imaging. MATERIALS AND METHODS: A local ethics committee approved the study, and all subjects gave fully informed written consent. An equilibrium CT protocol was developed using iohexol at 300 mg of iodine per milliliter (bolus of 1 mg per kilogram of body weight administered at a rate of 3 mL/sec, followed immediately by an infusion of 1.88 mL/kg per hour with CT imaging before and at 25 minutes after injection of bolus of contrast agent) and ECV within the myocardial septum measured using both equilibrium CT and equilibrium MR imaging in patients with severe aortic stenosis. Biopsy samples of the myocardial septum collected during valve replacement surgery were used for histologic quantification of extracellular fibrosis with picrosirius red staining. Equilibrium CT- and equilibrium MR imaging-derived ECV measurements were compared with histologically quantified fibrosis by using Pearson correlation. Agreement between equilibrium CT and equilibrium MR imaging was assessed by using Bland-Altman comparison. RESULTS: Twenty-three patients (16 male, seven female; mean age, 70.8 years; standard deviation, 8.3) were recruited. The mean percentage of histologic fibrosis was 18% (intersubject range, 5%-40%). There was a significant correlation between both equilibrium CT- and equilibrium MR imaging-derived ECV and percentage of histologic fibrosis (r = 0.71 [P < .001] and r = 0.84 [P < .0001], respectively). Equilibrium CT-derived ECV was significantly correlated to equilibrium MR imaging-derived ECV (r = 0.73). CONCLUSION: ECV measured by using equilibrium CT in patients with aortic stenosis correlates with histologic quantification of myocardial fibrosis and with ECV derived by using equilibrium MR imaging.


Assuntos
Fibrose Endomiocárdica/diagnóstico por imagem , Matriz Extracelular/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Biópsia , Meios de Contraste , Fibrose Endomiocárdica/patologia , Matriz Extracelular/patologia , Feminino , Humanos , Iohexol , Imageamento por Ressonância Magnética/métodos , Masculino , Coloração e Rotulagem
12.
Int J Comput Assist Radiol Surg ; 18(8): 1437-1449, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36790674

RESUMO

PURPOSE: Minimally invasive treatments for renal carcinoma offer a low rate of complications and quick recovery. One drawback of the use of computed tomography (CT) for needle guidance is the use of iodinated contrast agents, which require an increased X-ray dose and can potentially cause adverse reactions. The purpose of this work is to generalise the problem of synthetic contrast enhancement to allow the generation of multiple phases on non-contrast CT data from a real-world, clinical dataset without training multiple convolutional neural networks. METHODS: A framework for switching between contrast phases by conditioning the network on the phase information is proposed and compared with separately trained networks. We then examine how the degree of supervision affects the generated contrast by evaluating three established architectures: U-Net (fully supervised), Pix2Pix (adversarial with supervision), and CycleGAN (fully adversarial). RESULTS: We demonstrate that there is no performance loss when testing the proposed method against separately trained networks. Of the training paradigms investigated, the fully adversarial CycleGAN performs the worst, while the fully supervised U-Net generates more realistic voxel intensities and performed better than Pix2Pix in generating contrast images for use in a downstream segmentation task. Lastly, two models are shown to generalise to intra-procedural data not seen during the training process, also enhancing features such as needles and ice balls relevant to interventional radiological procedures. CONCLUSION: The proposed contrast switching framework is a feasible option for generating multiple contrast phases without the overhead of training multiple neural networks, while also being robust towards unseen data and enhancing contrast in features relevant to clinical practice.


Assuntos
Processamento de Imagem Assistida por Computador , Redes Neurais de Computação , Humanos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Radiografia , Crioterapia
13.
A A Pract ; 16(8): e01608, 2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-35960937

RESUMO

High-frequency jet ventilation (HFJV) can reduce organ movement that otherwise complicates percutaneous image-guided ablation (IGA) procedures. This study describes feasibility and safety of the technique in routine use. We describe our method for the use of HFJV and present 169 consecutive cases, including IGA of tumors of the lung, liver, kidney, and pancreas. Intended oncological treatment was delivered in all cases and HFJV used for the duration of treatment in all except one case. We describe the characteristics of patients, procedures, and adverse events. It is feasible to use HFJV as the routine standard of care for IGA.


Assuntos
Ventilação em Jatos de Alta Frequência , Neoplasias Hepáticas , Ventilação em Jatos de Alta Frequência/métodos , Humanos , Imunoglobulina A , Neoplasias Hepáticas/cirurgia , Radiografia Intervencionista/efeitos adversos , Tomografia Computadorizada por Raios X
14.
JACC Cardiovasc Imaging ; 15(12): 2082-2094, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36274040

RESUMO

BACKGROUND: Light chain (AL) and transthyretin (ATTR) amyloid fibrils are deposited in the extracellular space of the myocardium, resulting in heart failure and premature mortality. Extracellular expansion can be quantified by computed tomography, offering a rapid, cheaper, and more practical alternative to cardiac magnetic resonance, especially among patients with cardiac devices or on renal dialysis. OBJECTIVES: This study sought to investigate the association of extracellular volume fraction by computed tomography (ECVCT), myocardial remodeling, and mortality in patients with systemic amyloidosis. METHODS: Patients with confirmed systemic amyloidosis and varying degrees of cardiac involvement underwent electrocardiography-gated cardiac computed tomography. Whole heart and septal ECVCT was analyzed. All patients also underwent clinical assessment, electrocardiography, echocardiography, serum amyloid protein component, and/or technetium-99m (99mTc) 3,3-diphosphono-1,2-propanodicarboxylic acid scintigraphy. ECVCT was compared across different extents of cardiac infiltration (ATTR Perugini grade/AL Mayo stage) and evaluated for its association with myocardial remodeling and all-cause mortality. RESULTS: A total of 72 patients were studied (AL: n = 35, ATTR: n = 37; median age: 67 [IQR: 59-76] years, 70.8% male). Mean septal ECVCT was 42.7% ± 13.1% and 55.8% ± 10.9% in AL and ATTR amyloidosis, respectively, and correlated with indexed left ventricular mass (r = 0.426; P < 0.001), left ventricular ejection fraction (r = 0.460; P < 0.001), N-terminal pro-B-type natriuretic peptide (r = 0.563; P < 0.001), and high-sensitivity troponin T (r = 0.546; P < 0.001). ECVCT increased with cardiac amyloid involvement in both AL and ATTR amyloid. Over a mean follow-up of 5.3 ± 2.4 years, 40 deaths occurred (AL: n = 14 [35.0%]; ATTR: n = 26 [65.0%]). Septal ECVCT was independently associated with all-cause mortality in ATTR (not AL) amyloid after adjustment for age and septal wall thickness (HR: 1.046; 95% CI: 1.003-1.090; P = 0.037). CONCLUSIONS: Cardiac amyloid burden quantified by ECVCT is associated with adverse cardiac remodeling as well as all-cause mortality among ATTR amyloid patients. ECVCT may address the need for better identification and risk stratification of amyloid patients, using a widely accessible imaging modality.


Assuntos
Tomografia Computadorizada por Raios X , Função Ventricular Esquerda , Humanos , Masculino , Idoso , Feminino , Volume Sistólico , Valor Preditivo dos Testes , Tomografia
15.
Diagn Interv Radiol ; 27(5): 677-683, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34318754

RESUMO

Colorectal cancer liver metastases (CRLMs) are common. Treating CRLMs with thermal ablation can prolong survival, but compared to lesions smaller than 3 cm, local control rates and overall survival are relatively worse with larger, intermediate (3-5 cm) lesions. Local recurrence rates range between 1.7%-20.2% and 6.7%-68.9% for CRLMs less than 3 cm and greater than 3 cm, respectively. Worse outcomes are also present when ablating intermediate size hepatocellular carcinoma (HCC) and there are some pathological similarities with CRLMs, namely the presence of micrometastatic disease. Combining ablation with transarterial chemoembolization is more effective in treating intermediate-size HCC than ablation alone. A meta-analysis of robust randomized controlled trials demonstrated long-term improved survival with combination therapy compared to ablation alone (odds ratio at 1, 3 and 5 years of 2.74, 2.77 and 5.23, respectively). There is, however, minimal evidence for combination therapy in CRLMs, limited to a handful of studies that are predominantly retrospective and have heterogeneous inclusion criteria. Given the difficulty in successfully treating intermediate CRLMs, the strong evidence for combination therapy in intermediate HCC and potential pathological similarities, formal evaluation of combination treatment in CRLM is merited. This review highlights existing evidence for treatment of intermediate-size liver lesions and highlights where trials in CRLMs should focus.


Assuntos
Carcinoma Hepatocelular , Ablação por Cateter , Quimioembolização Terapêutica , Neoplasias Colorretais , Neoplasias Hepáticas , Carcinoma Hepatocelular/terapia , Humanos , Neoplasias Hepáticas/cirurgia , Recidiva Local de Neoplasia , Estudos Retrospectivos , Resultado do Tratamento
16.
Urol Oncol ; 39(10): 728.e1-728.e6, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33485763

RESUMO

BACKGROUND: To evaluate the prevalence, density, and distribution of prostate calcification in patients with prostate cancer. METHODS: Patients who underwent both Gallium-68 PSMA PET/CT and MRI of the prostate over the course of a year were selected for analysis. The CT images with visible calcifications within the prostate were included and calcifications automatically isolated using a threshold of 130 HU. The corresponding multiparametric MRI was assessed and the peripheral zone, transition zone, MRI-visible tumor, and urethra manually contoured. The contoured MRI and CT images were registered using rigid registration, and calcifications mapped automatically to the MRI contours. RESULTS: A total of 85 men (age range 50-88, mean 69 years, standard deviation 7.2 years) were assessed. The mean serum Prostate Specific Antigen PSA was 16.7, range 0.12 to 94.4. Most patients had intermediate-risk disease (68%; Gleason grade group 2 and 3), 26% had high-risk disease (Gleason grade group 4 and 5), and 6% had low-risk disease (Gleason grade group 1). Forty-six patients out of 85 (54%) had intraprostatic calcification. Calcification occurred more in transition zone than the peripheral zone (65% vs. 35%). The mean density of the calcification was 227 HU (min 133, max 1,966 HU). In 12 patients, the calcification was within an MRI-visible tumor, in 24 patients, there were calcifications within a 9 mm distance of the tumor border, and in 9 patients, there were calcifications located between the urethra and tumor. CONCLUSIONS: Calcifications are common in patients with prostate cancer. Their density and location may make them a significant consideration when planning treatment or retreatment with some types of minimally invasive therapy.


Assuntos
Próstata/patologia , Neoplasias da Próstata/radioterapia , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade
17.
Prostate Cancer Prostatic Dis ; 24(3): 612-622, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33558660

RESUMO

BACKGROUND: Biopsy after external beam radiotherapy (EBRT) for localised prostate cancer (PCa) is an infrequently used but potentially valuable technique to evaluate local recurrence and predict long-term outcomes. METHODS: We performed a meta-analysis of studies until March 2020 where a post-EBRT biopsy was performed on patients with low-to intermediate risk PCa, according to the Preferred Reporting Items for Systematic Review and Meta-analysis (PRISMA) statement. The primary outcome was the aggregate post-EBRT positive biopsy rate (≥2 years after EBRT) and the associated odds ratio (OR) of a positive biopsy on biochemical failure (BCF), distant metastasis-free survival (DMFS) and prostate cancer-specific mortality (PCSM). A sensitivity analysis was performed which examined biopsy rate as a function of post-EBRT biopsy protocol, PCa risk, ADT usage and radiation dose. RESULTS: A total of 22 studies were included, of which 10 were randomised controlled trials and 12 were cohort studies. Nine out of the 22 studies used dosing regimens consistent with the 2020 NCCN radiotherapy guidelines. The weighted-average positive biopsy rate across all 22 studies was 32% (95%-CI: 25-39%, n = 3017). In studies where post-treatment biopsy was part of the study protocol, the rate was 35% (95%-CI: 21-38%, n = 2450). In the subgroup of studies that conformed to the 2020 NCCN radiotherapy guidelines, this rate was 22% (95% CI: 19-41%, n = 832). Patients with positive biopsy had a 10-fold higher odds of developing BCF (OR of 10.3, 95%-CI: 3.7-28.7, p < 0.00001), 3-fold higher odds of developing distant metastasis (OR 3.1, 95%-CI: 2.1-4.7, p < 0.00001) and 5-fold higher odds of dying from their PCa (OR 5.1, 95%-CI: 2.6-10, p < 0.00001). CONCLUSION: A positive biopsy after EBRT is associated with a poor prognosis compared to a negative biopsy. The post-EBRT positive biopsy rate is an important measure which provides additional insight when comparing EBRT to other treatment modalities for PCa.


Assuntos
Braquiterapia/efeitos adversos , Recidiva Local de Neoplasia/diagnóstico , Neoplasias da Próstata/radioterapia , Biópsia , Humanos , Masculino , Recidiva Local de Neoplasia/etiologia , Recidiva Local de Neoplasia/cirurgia , Prognóstico , Neoplasias da Próstata/patologia
18.
Br J Radiol ; 94(1118): 20200854, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-32960674

RESUMO

Renal cryoablation is a treatment option for early stage renal cell carcinomas with excellent oncological outcomes and low morbidity. This review outlines the technique of renal cryoablation and provides a guide for interventional radiologists on setting up an integrated service within a renal cancer network multidisciplinary setting. Patient selection and preparation, together with the technical aspects which ensure optimal oncological outcomes and avoid collateral damage to adjacent organs are highlighted.


Assuntos
Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/cirurgia , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/cirurgia , Radiologia Intervencionista/métodos , Tomografia Computadorizada por Raios X/métodos , Criocirurgia , Humanos , Rim/diagnóstico por imagem , Rim/cirurgia
19.
J Clin Oncol ; 39(35): 3897-3907, 2021 12 10.
Artigo em Inglês | MEDLINE | ID: mdl-34541864

RESUMO

PURPOSE: To study the impact of transarterial Yttrium-90 radioembolization (TARE) in combination with second-line systemic chemotherapy for colorectal liver metastases (CLM). METHODS: In this international, multicenter, open-label phase III trial, patients with CLM who progressed on oxaliplatin- or irinotecan-based first-line therapy were randomly assigned 1:1 to receive second-line chemotherapy with or without TARE. The two primary end points were progression-free survival (PFS) and hepatic PFS (hPFS), assessed by blinded independent central review. Random assignment was performed using a web- or voice-based system stratified by unilobar or bilobar disease, oxaliplatin- or irinotecan-based first-line chemotherapy, and KRAS mutation status. RESULTS: Four hundred twenty-eight patients from 95 centers in North America, Europe, and Asia were randomly assigned to chemotherapy with or without TARE; this represents the intention-to-treat population and included 215 patients in the TARE plus chemotherapy group and 213 patients in the chemotherapy alone group. The hazard ratio (HR) for PFS was 0.69 (95% CI, 0.54 to 0.88; 1-sided P = .0013), with a median PFS of 8.0 (95% CI, 7.2 to 9.2) and 7.2 (95% CI, 5.7 to 7.6) months, respectively. The HR for hPFS was 0.59 (95% CI, 0.46 to 0.77; 1-sided P < .0001), with a median hPFS of 9.1 (95% CI, 7.8 to 9.7) and 7.2 (95% CI, 5.7 to 7.6) months, respectively. Objective response rates were 34.0% (95% CI, 28.0 to 40.5) and 21.1% (95% CI, 16.2 to 27.1; 1-sided P = .0019) for the TARE and chemotherapy groups, respectively. Median overall survival was 14.0 (95% CI, 11.8 to 15.5) and 14.4 months (95% CI, 12.8 to 16.4; 1-sided P = .7229) with a HR of 1.07 (95% CI, 0.86 to 1.32) for TARE and chemotherapy groups, respectively. Grade 3 adverse events were reported more frequently with TARE (68.4% v 49.3%). Both groups received full chemotherapy dose intensity. CONCLUSION: The addition of TARE to systemic therapy for second-line CLM led to longer PFS and hPFS. Further subset analyses are needed to better define the ideal patient population that would benefit from TARE.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Quimiorradioterapia/mortalidade , Neoplasias Colorretais/terapia , Embolização Terapêutica/mortalidade , Neoplasias Hepáticas/terapia , Radioisótopos de Ítrio/uso terapêutico , Bevacizumab/administração & dosagem , Estudos de Casos e Controles , Neoplasias Colorretais/patologia , Feminino , Seguimentos , Humanos , Irinotecano/administração & dosagem , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Oxaliplatina/administração & dosagem , Prognóstico , Taxa de Sobrevida
20.
Br J Radiol ; 93(1105): 20190340, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31596121

RESUMO

OBJECTIVE: To compare key characteristics of interventional radiology (IR) training in the UK with four other English-speaking countries (USA, Canada, Australia and New Zealand) and summarise requirements for training. METHODS: Main features examined were career pathway and requirements, examinations required, specific competition for IR and the process of applying for training as an international medical graduate. Data were collected from official governing body publications, literature and personal experience. RESULTS: Several differences were highlighted, including length of training (ranging from 6 to 9 years after medical school), length of IR-specific training (ranging from 1 to 3 years) and examinations required (USA and Canada have additional IR-specific examinations). The level of competition is generally high, in all countries. CONCLUSIONS: With the demand for IR services set to increase over the next few years, it is crucial that more IR specialists are trained to meet this demand. Awareness of training structures in other countries can highlight opportunity and pitfalls, and help ensure the number of highly trained interventional radiologists in the UK continues to grow.


Assuntos
Educação de Pós-Graduação em Medicina/tendências , Radiologia Intervencionista/educação , Austrália , Canadá , Escolha da Profissão , Avaliação Educacional , Humanos , Nova Zelândia , Reino Unido , Estados Unidos
SELEÇÃO DE REFERÊNCIAS