Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Indian Pediatr ; 61(6): 578-584, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38584412

RESUMO

Congenital hyperinsulinism (CHI) is a rare condition but is a common cause of severe and persistent hypoglycemia in early life. Prompt recognition of CHI is critical to prevent the impact of neuroglycopenia and consequent lifelong neurodisability. It is important to be alert to the possibility of CHI in newborn babies with recurrent hypoglycemia associated with high glucose requirements. Pediatricians are advised to mitigate the risk of hypoglycemia by early treatment with high concentration dextrose and intravenous glucagon infusions. Specific medical therapies with diazoxide and/or somatostatin receptor analogues may be commenced after the finding of detectable insulin at hypoglycemia, a biochemical characteristic of CHI. Early exploration of genetic etiology is recommended, chiefly in the search for a focal form, amenable to limited pancreatic surgery. Genetic ascertainment is also useful to understand the basis of disease, variable responses to medical therapies and escalation of conservative treatment to subtotal pancreatectomy. CHI is a heterogeneous disorder with varying natural history. Many newborns and infants with CHI have severe and complex illness features; their long-term care is best achieved through review at specialist centers.


Assuntos
Hiperinsulinismo Congênito , Humanos , Hiperinsulinismo Congênito/diagnóstico , Hiperinsulinismo Congênito/terapia , Recém-Nascido , Pediatras , Lactente , Hipoglicemia
2.
Front Endocrinol (Lausanne) ; 15: 1338980, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38616820

RESUMO

Introduction: Neonatal and early-life hypoglycaemia, is a frequent finding but is often non-specific and asymptomatic, making detection and diagnosis challenging. Hypoglycaemia-induced cerebral injury can be identified by magnetic resonance imaging (MRI) changes in cerebral white matter, occipital lobes, and posterior parietotemporal regions. It is unknown if children may have hypoglycaemic brain injury secondary to unrecognised hypoglycaemia in early life. We have examined retrospective radiological findings of likely brain injury by neuroimaging to investigate the existence of previous missed hypoglycaemic events. Methods: Retrospective MRI data in children in a single tertiary centre, over a ten-year period was reviewed to identify potential cases of unrecognised early-life hypoglycaemia. A detailed search from an electronic radiology repository involved the term "hypoglycaemia'' from text-based reports. The initial report was used for those who required serial scanning. Images specific to relevant reports were further reviewed by a designated paediatric neuroradiologist to confirm likely hypoglycaemia induced brain injury. Medical records of those children were subsequently reviewed to assess if the hypoglycaemia had been diagnosed prior to imaging. Results: A total of 107 MR imaging reports were identified for review, and 52 (48.5%) showed typical features strongly suggestive of hypoglycaemic brain injury. Medical note review confirmed no documented clinical information of hypoglycaemia prior to imaging in 22 (42%) patients, raising the likelihood of missed hypoglycaemic events resulting in brain injury. Conclusions: We have identified the existence of unrecognised childhood hypoglycaemia through neuroimaging review. This study highlights the need for heightened awareness of early life hypoglycaemia to prevent adverse neurological outcomes later in childhood.


Assuntos
Lesões Encefálicas , Hipoglicemia , Criança , Humanos , Encéfalo/diagnóstico por imagem , Hipoglicemia/diagnóstico por imagem , Hipoglicemiantes , Imageamento por Ressonância Magnética , Estudos Retrospectivos
3.
J Diabetes Sci Technol ; : 19322968241245923, 2024 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-38616550

RESUMO

INTRODUCTION: Patients with congenital hyperinsulinism (HI) require constant glucose monitoring to detect and treat recurrent and severe hypoglycemia. Historically, this has been achieved with intermittent self-monitoring blood glucose (SMBG), but patients are increasingly using continuous glucose monitoring (CGM). Given the rapidity of CGM device development, and increasing calls for CGM use from HI families, it is vital that new devices are evaluated early. METHODS: We provided two months of supplies for the new Dexcom G7 CGM device to 10 patients with HI who had recently finished using the Dexcom G6. Self-monitoring blood glucose was performed concurrently with paired readings providing accuracy calculations. Patients and families completed questionnaires about device use at the end of the two-month study period. RESULTS: Compared to the G6, the G7 showed a significant reduction in mean absolute relative difference (25%-18%, P < .001) and in the over-read error (Bland Altman +1.96 SD; 3.54 mmol/L to 2.95 mmol/L). This resulted in an improvement in hypoglycemia detection from 42% to 62% (P < .001). Families reported an overall preference for the G7 but highlighted concerns about high sensor failure rates. DISCUSSION: The reduction in mean absolute relative difference and over-read error and the improvement in hypoglycemia detection implies that the G7 is a safer and more useful device in the management of hypoglycemia for patients with HI. Accuracy, while improved from previous devices, remains suboptimal with 40% of hypoglycemia episodes not detected.

4.
Eur J Hum Genet ; 32(7): 813-818, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38605124

RESUMO

Persistent congenital hyperinsulinism (HI) is a rare genetically heterogeneous condition characterised by dysregulated insulin secretion leading to life-threatening hypoglycaemia. For up to 50% of affected individuals screening of the known HI genes does not identify a disease-causing variant. Large deletions have previously been used to identify novel regulatory regions causing HI. Here, we used genome sequencing to search for novel large (>1 Mb) deletions in 180 probands with HI of unknown cause and replicated our findings in a large cohort of 883 genetically unsolved individuals with HI using off-target copy number variant calling from targeted gene panels. We identified overlapping heterozygous deletions in five individuals (range 3-8 Mb) spanning chromosome 20p11.2. The pancreatic beta-cell transcription factor gene, FOXA2, a known cause of HI was deleted in two of the five individuals. In the remaining three, we found a minimal deleted region of 2.4 Mb adjacent to FOXA2 that encompasses multiple non-coding regulatory elements that are in conformational contact with FOXA2. Our data suggests that the deletions in these three children may cause disease through the dysregulation of FOXA2 expression. These findings provide new insights into the regulation of FOXA2 in the beta-cell and confirm an aetiological role for chromosome 20p11.2 deletions in syndromic HI.


Assuntos
Deleção Cromossômica , Cromossomos Humanos Par 20 , Hiperinsulinismo Congênito , Fator 3-beta Nuclear de Hepatócito , Humanos , Fator 3-beta Nuclear de Hepatócito/genética , Fator 3-beta Nuclear de Hepatócito/metabolismo , Hiperinsulinismo Congênito/genética , Hiperinsulinismo Congênito/patologia , Cromossomos Humanos Par 20/genética , Feminino , Masculino , Sequências Reguladoras de Ácido Nucleico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA