Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Spine J ; 29(Suppl 2): 145-148, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-31832873

RESUMO

STUDY DESIGN: Case report. PURPOSE: The authors used spine shortening as an alternative strategy to intercalary graft fixation to restore permanent spine stability for a 17-month-old infant who received total en bloc spondylectomy (TES) of T11 to treat an embryonic rhabdomyosarcoma. TES involves complete removal of vertebra, compensated by spine reconstruction using intercalary allografts and permanent posterior instrumentation, which is not possible for skeletally immature patients with high growth potential and non-ossified vertebrae. METHODS: Surgery was performed over two consecutive days. During the first day, the tumor was released from its dorsal attachments through the posterior approach. During the second day, the tumor was dissected and excised through the anterior approach, leaving a gap between T10 and T12. The two vertebrae were then drawn toward each other until the gap was bridged. The dural sac slipped into the canal under T10 and T12 with no observable kinking. RESULTS: Fifteen weeks after surgery, thoraco-abdominal CT confirmed fusion of the T10 and T12 vertebral bodies. Three years later, the patient lives a normal life with no major neurological deficits or recurrence of sarcoma. CONCLUSIONS: This case report is the first to demonstrate the feasibility of TES with spine shortening of an entire thoracic segment without spine kinking or damage in an infant. This unprecedented surgical technique allowed complete removal of an embryonic rhabdomyosarcoma, while granting rapid stability and growth potential. LEVEL OF EVIDENCE: IV.


Assuntos
Procedimentos de Cirurgia Plástica , Humanos , Lactente , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Recidiva Local de Neoplasia/cirurgia , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Neoplasias da Coluna Vertebral/cirurgia , Vértebras Torácicas/diagnóstico por imagem , Vértebras Torácicas/cirurgia
2.
Eur Spine J ; 26(11): 2906-2916, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28528479

RESUMO

PURPOSE: The goal of this study was to compare the accuracy of a novel intraoperative cone beam computed tomography (CBCT) imaging technique with that of conventional computed tomography (CT) scans for assessment of pedicle screw placement and breach detection. METHODS: Three hundred and forty-eight pedicle screws were inserted in 58 patients between October 2013 and March 2016. All patients had an intraoperative CBCT scan and a conventional CT scan to verify the placement of the screws. The CBCT and CT images were reviewed by two surgeons to assess the accuracy of screw placement and detect pedicle breaches using two established classification systems. Agreement on screw placement between intraoperative CBCT and postoperative CT was assessed using Kappa and Gwet's coefficients. Using CT scanning as the gold standard, the sensitivity, specificity, positive predictive value, and negative predictive value were calculated to determine the ability of CBCT imaging to accurately evaluate screw placement. RESULTS: The Kappa coefficient was 0.78 using the Gertzbein classification and 0.80 using the Heary classification, indicating a substantial agreement between the intraoperative CBCT and postoperative CT images. Gwet's coefficient was 0.94 for both classifications, indicating almost perfect agreement. The sensitivity, specificity, positive predictive value and negative predictive value of the CBCT images were 77, 98, 86, and 96%, respectively, for the Gertzbein classification and 79, 98, 88, and 96%, respectively, for the Heary classification. CONCLUSIONS: Intraoperative CBCT provides accurate assessment of pedicle screw placement and enables intraoperative repositioning of misplaced screws. This technique may make postoperative CT imaging unnecessary.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Parafusos Pediculares , Fusão Vertebral , Cirurgia Assistida por Computador , Tomografia Computadorizada de Feixe Cônico/métodos , Tomografia Computadorizada de Feixe Cônico/estatística & dados numéricos , Humanos , Período Pós-Operatório , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Fusão Vertebral/instrumentação , Fusão Vertebral/métodos , Fusão Vertebral/estatística & dados numéricos , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/métodos , Cirurgia Assistida por Computador/estatística & dados numéricos
3.
Eur Spine J ; 26(11): 2818-2827, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28735464

RESUMO

PURPOSE: Spine surgery still remains a challenge for every spine surgeon, aware of the potential serious outcomes of misplaced instrumentation. Though many studies have highlighted that using intraoperative cone beam CT imaging and navigation systems provides higher accuracy than conventional freehand methods for placement of pedicle screws in spine surgery, few studies are concerned about how to reduce radiation exposure for patients with the use of such technology. One of the main focuses of this study is based on the ALARA principle (as low as reasonably achievable). METHOD: A prospective randomized trial was conducted in the hybrid operating room between December 2015 and December 2016, including 50 patients operated on for posterior instrumented thoracic and/or lumbar spinal fusion. Patients were randomized to intraoperative 3D acquisition high-dose (standard dose) or low-dose protocol, and a total of 216 pedicle screws were analyzed in terms of screw position. Two different methods were used to measure ionizing radiation: the total skin dose (derived from the dose-area product) and the radiation dose evaluated by thermoluminescent dosimeters on the surgical field. RESULTS: According to Gertzbein and Heary classifications, low-dose protocol provided a significant higher accuracy of pedicle screw placement than the high-dose protocol (96.1 versus 92%, respectively). Seven screws (3.2%), all implanted with the high-dose protocol, needed to be revised intraoperatively. The use of low-dose acquisition protocols reduced patient exposure by a factor of five. CONCLUSION: This study emphasizes the paramount importance of using low-dose protocols for intraoperative cone beam CT imaging coupled with the navigation system, as it at least does not affect the accuracy of pedicle screw placement and irradiates drastically less.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Vértebras Lombares , Doses de Radiação , Fusão Vertebral/métodos , Vértebras Torácicas , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Parafusos Pediculares , Estudos Prospectivos , Vértebras Torácicas/diagnóstico por imagem , Vértebras Torácicas/cirurgia
4.
Eur Spine J ; 26(11): 2917-2926, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28631190

RESUMO

PURPOSE: The goals of this study were to assess the accuracy of pedicle screw insertion using an intraoperative cone beam computed tomography (CBCT) system, and to analyze the factors potentially influencing this accuracy. METHODS: Six hundred and ninety-five pedicle screws were inserted in 118 patients between October 2013 and March 2016. Screw insertion was performed using 2D-fluoroscopy or CBCT-based navigation. Accuracy was assessed in terms of breach and reposition. All the intraoperative CBCT scans, done after screw insertion, were reviewed to assess the accuracy of screw placement using two established classification systems: Gertzbein and Heary. Generalized linear mixed models were used to model the odds (95% CI) for a screw to lead to a breach according to the independent variables. RESULTS: The breach rate was 11.7% using the Gertzbein classification and 15.4% using the Heary classification. Seventeen screws (2.4%) were repositioned intraoperatively. The only factor affecting statistically the odds to have a breach was the indication of surgery. The patients with non-degenerative disease had a significantly higher risk of breach than those with degenerative disease. CONCLUSION: Use of intraoperative CBCT as 2D-fluoroscopy or coupled with a navigation system for pedicle screw insertion is accurate in terms of breach occurrence and reposition. However, these rates depend on the classification or grading system used. Use of a navigation system does not decrease the risk of breach significantly. And the risk of breach is higher in non-degenerative conditions (trauma, scoliosis, infection, and malignancy disease) than in degenerative diseases.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Parafusos Pediculares/estatística & dados numéricos , Fusão Vertebral , Cirurgia Assistida por Computador , Tomografia Computadorizada de Feixe Cônico/métodos , Tomografia Computadorizada de Feixe Cônico/estatística & dados numéricos , Humanos , Degeneração do Disco Intervertebral/diagnóstico por imagem , Degeneração do Disco Intervertebral/cirurgia , Estudos Retrospectivos , Fusão Vertebral/métodos , Fusão Vertebral/estatística & dados numéricos , Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/cirurgia , Cirurgia Assistida por Computador/métodos , Cirurgia Assistida por Computador/estatística & dados numéricos
5.
Chirurgia (Bucur) ; 111(5): 439-444, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27819644

RESUMO

The pelvis bone resection-reconstruction surgery is one of the most challenging fields in orthopedics. Being applied for tumors, as for other complex reconstruction cases, this type of surgery needs careful planning and is time consuming, in order to obtain proper accuracy. Unfortunately not all the time the expected accuracy is met, with consequences for the patients. PSI proved to provide good cutting accuracy during simulated tumor surgery within the pelvis. This article present a series of 4 patients operated in our department between June 2014 and Mars 2015 for tumors resectionreconstructions. The patients were imaged using a CT and an MRI scan and the images were reconstructed in 3D. According to the bone bank stock, the most similar allograft was chosen and the stored CT scan was reconstructed in 3D. Patient specific instruments (PSI) were designed and manufactured using rapid-prototyping technology for the resection of the native tissues as for the resection of the careful selected hemipelvic allografts. Allografts fitting to the pelvis of the patients was excellent and allowed stable osteosynthesis.


Assuntos
Neoplasias Ósseas/cirurgia , Carcinoma de Células Renais/cirurgia , Procedimentos Ortopédicos/instrumentação , Ossos Pélvicos/cirurgia , Procedimentos de Cirurgia Plástica/instrumentação , Sarcoma de Ewing/cirurgia , Adolescente , Adulto , Biópsia , Neoplasias Ósseas/complicações , Neoplasias Ósseas/tratamento farmacológico , Neoplasias Ósseas/patologia , Carcinoma de Células Renais/complicações , Carcinoma de Células Renais/tratamento farmacológico , Carcinoma de Células Renais/secundário , Humanos , Masculino , Pessoa de Meia-Idade , Neurofibromatose 1/complicações , Procedimentos Ortopédicos/métodos , Ossos Pélvicos/patologia , Procedimentos de Cirurgia Plástica/métodos , Estudos Retrospectivos , Fatores de Risco , Sarcoma de Ewing/complicações , Sarcoma de Ewing/tratamento farmacológico , Sarcoma de Ewing/patologia , Resultado do Tratamento , Síndrome de Wolff-Parkinson-White/complicações
6.
J Med Case Rep ; 18(1): 138, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38556889

RESUMO

BACKGROUND: To our knowledge, there is no previous report in the literature of non-traumatic neglected complete cervical spine dislocation characterized by anterior spondyloptosis of C4, extreme head drop, and irreducible cervicothoracic kyphosis. CASE PRESENTATION: We report the case of a 33-year-old Caucasian man with a 17-year history of severe immune polymyositis and regular physiotherapy who presented with severe non-reducible kyphosis of the cervicothoracic junction and progressive tetraparesia for several weeks after a physiotherapy session. Radiographs, computed tomography, and magnetic resonance imaging revealed a complete dislocation at the C4-C5 level, with C4 spondyloptosis, kyphotic angulation, spinal cord compression, and severe myelopathy. Due to recent worsening of neurological symptoms, an invasive treatment strategy was indicated. The patient's neurological status and spinal deformity greatly complicated the anesthetic and surgical management, which was planned after extensive multidisciplinary discussion and relied on close collaboration between the orthopedic surgeon and the anesthetist. Regarding anesthesia, difficult airway access was expected due to severe cervical angulation, limited mouth opening, and thyromental distance, with high risk of difficult ventilation and intubation. Patient management was further complicated by a theoretical risk of neurogenic shock, motor and sensory deterioration, instability due to position changes during surgery, and postoperative respiratory failure. Regarding surgery, a multistage approach was carefully planned. After a failed attempt at closed reduction, a three-stage surgical procedure was performed to reduce displacement and stabilize the spine, resulting in correct spinal realignment and fixation. Progressive complete neurological recovery was observed. CONCLUSION: This case illustrates the successful management of a critical situation based on a multidisciplinary collaboration involving radiologists, anesthesiologists, and spine surgeons.


Assuntos
Cifose , Compressão da Medula Espinal , Traumatismos da Coluna Vertebral , Masculino , Humanos , Adulto , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Vértebras Cervicais/lesões , Compressão da Medula Espinal/diagnóstico por imagem , Compressão da Medula Espinal/etiologia , Compressão da Medula Espinal/cirurgia , Traumatismos da Coluna Vertebral/complicações , Radiografia , Cifose/diagnóstico por imagem , Cifose/etiologia , Cifose/cirurgia
7.
Eur Spine J ; 22(8): 1868-76, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23397190

RESUMO

PURPOSE: To examine the time needed from a surgeon's viewpoint to treat a patient operated for lumbar spinal stenosis. We firstly aimed to give evidence of the wide ranging duration of standardized procedure. Secondly, we investigated factors affecting the time allocated to each patient. METHODS: 438 medical records of patients operated on for lumbar decompression without fusion (2005-2011) were retrospectively examined. Primary data were operative time (OT, min), length of stay (LoS, days) and number of postoperative visits. A fourth parameter was calculated, the time spent per patient (TSPP, min) by summing the time spent in surgery, during inpatient and outpatient follow-up visits. Factors that influenced these medical resources were examined. RESULTS: Median (5th-95th percentile) LoS was 5 days (2-15), OT 106 min (60-194), number of medical visits 5 (2-11) and TSPP 329 min (206-533). In descending order, factors predicting LoS were age, no. of levels, sex, operative technique, cardiovascular risk index, dural tear and haematoma. Factors predicting OT were number of levels, dural tear, foraminotomy, synovial cyst and body mass index. The statistical model could predict 36% of the TSPP variance. We recommend that surgeons add 35 min for each level, 29 min for patients over 65 years, 30 min for women, 132 min for dural tear and 108 min for epidural haematoma. CONCLUSION: TSPP treated for lumbar spinal stenosis is highly variable, yet partially predictable. These data may help individual surgeons or heads of departments to plan their activities.


Assuntos
Vértebras Lombares/cirurgia , Duração da Cirurgia , Procedimentos Ortopédicos , Estenose Espinal/cirurgia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Índice de Massa Corporal , Feminino , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Cuidados Pós-Operatórios , Estudos Retrospectivos , Fatores Sexuais
8.
Eur Spine J ; 22(11): 2399-406, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23702685

RESUMO

PURPOSE: Adolescent idiopathic scoliotic (AIS) deformity induces excessive oxygen consumption correlated to a bilateral increase of lumbo-pelvic muscles timing activity (EMG) during gait. Wearing a brace, the usual treatment for AIS, by supporting the spine and the pelvis, would generate lumbo-pelvic muscular relaxation and consequently reduce excessive oxygen consumption. The purpose of this study was to evaluate the short-term effect of bracing on gait biomechanics in scoliotic spine when compared with normal braced spine. METHODS: Thirteen healthy volunteers were compared to 13 AIS girls. In both samples, gait analysis was assessed using a three-dimensional motion analysis, including synchronous kinematic, electromyographic, mechanical and energy measurements, first without brace, then wearing a brace. RESULTS: For scoliotic patients, comparison of in-brace and out-brace situations revealed a significant decrease of frontal pelvis (p < 0.001), hip (p < 0.001) and shoulder (p = 0.004) motion in brace associated with a significant reduction of pelvis rotation (p = 0.003). However, the brace did not change significantly the lumbo-pelvic muscle activity duration (EMG) or the mechanical and energetic parameters. Transversal pelvis motion was reduced by 39% (p = 0.04), frontal hip and shoulder motions by 23% (p = 0.004) and 30% (p = 0.01) respectively, and energy cost of walking remained increased by 37% in braced AIS girls relatively to braced healthy subjects. Mechanical and electromyographic variables were not significantly different between the two braced populations during gait except for the gluteus medius muscle that showed bilaterally an increase of duration of electrical activity in healthy subjects and contrarily a decrease in AIS patients (healthy: -3.5 ± 9.6% of gait cycle vs. scoliotic: 3.7 ± 7.7% of gait cycle; p = 0.04). CONCLUSIONS: Bracing changed neither the oxygen consumption nor the timing of the lumbo-pelvic muscles activity in both groups during gait. However, in brace the timing activity of bilateral gluteus medius muscles tended to decrease in AIS patients and increase in healthy subjects. Moreover, braced AIS patients had more restricted frontal hips and shoulder motion as well as pelvis rotation than braced healthy subjects.


Assuntos
Braquetes , Marcha , Escoliose/terapia , Adolescente , Fenômenos Biomecânicos , Feminino , Marcha/fisiologia , Humanos , Músculo Esquelético/fisiopatologia , Consumo de Oxigênio , Escoliose/fisiopatologia , Caminhada/fisiologia
9.
Stud Health Technol Inform ; 176: 95-8, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22744467

RESUMO

In idiopathic scoliotic patients, dynamical intervertebral efforts acting between vertebrae seem to be correlated with the spinal deformity. The quantification of these efforts, which is useful for the orthopedic surgeons to set up their surgical planning is the final objective of the present research. As a first step, we focus in this contribution on the geometrical reconstruction of the spine and especially on the rotation sequences between vertebrae in a multibody approach. The reconstruction process is performed in the standing position with possible bending, using an optimization process based on geometrical data reconstructed from radiographs. The obtained results will serve as input for the subsequent gait motion for which the limited set of geometrical information must be compensated.


Assuntos
Disco Intervertebral/fisiopatologia , Modelos Biológicos , Movimento , Amplitude de Movimento Articular , Escoliose/fisiopatologia , Coluna Vertebral/fisiopatologia , Articulação Zigapofisária/fisiopatologia , Simulação por Computador , Humanos
10.
Cell Tissue Bank ; 12(4): 281-8, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20703816

RESUMO

Freeze-drying and irradiation are common process used by tissue banks to preserve and sterilize bone allografts. Freeze dried irradiated bone is known to be more brittle. Whether bone brittleness is due to irradiation alone, temperature during irradiation or to a synergetic effect of the freeze-drying-irradiation process was not yet assessed. Using a left-right femoral head symmetry model, 822 compression tests were performed to assess the influence of sequences of a 25 kGy irradiation with and without freeze-drying compared to the unprocessed counterpart. Irradiation of frozen bone did not cause any significant reduction in ultimate strength, stiffness and work to failure. The addition of the freeze-drying process before or after irradiation resulted in a mean drop of 35 and 31% in ultimate strength, 14 and 37% in stiffness and 46 and 37% in work to failure. Unlike irradiation at room temperature, irradiation under dry ice of solvent-detergent treated bone seemed to have no detrimental effect on mechanical properties of cancellous bone. Freeze-drying bone without irradiation had no influence on mechanical parameters, but the addition of irradiation to the freeze-drying step or the reverse sequence showed a detrimental effect and supports the idea of a negative synergetic effect of both procedures. These findings may have important implications for bone banking.


Assuntos
Osso e Ossos/fisiologia , Osso e Ossos/efeitos da radiação , Raios gama , Idoso , Fenômenos Biomecânicos/efeitos da radiação , Força Compressiva/efeitos da radiação , Gelo-Seco , Liofilização , Humanos
11.
Acta Orthop ; 81(2): 250-5, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20175643

RESUMO

BACKGROUND AND PURPOSE: Massive bone allografts are used when surgery causes large segmental defects. Shape-matching is the primary criterion for selection of an allograft. The current selection method, based on 2-dimensional template comparison, is inefficient for 3-dimensional complex bones. We have analyzed a 3-dimensional (3-D) registration method to match the anatomy of the allograft with that of the recipient. METHODS: 3-D CT-based registration was performed to match the shapes of both bones. We used the registration to align the allograft volume onto the recipient's bone. Hemipelvic allograft selection was tested in 10 virtual recipients with a panel of 10 potential allografts, including one from the recipient himself (trap graft). 4 observers were asked to visually inspect the superposition of allograft over the recipient, to classify the allografts into 4 categories according to the matching of anatomic zones, and to select the 3 best matching allografts. The results obtained using the registration method were compared with those from a previous study on the template method. RESULTS: Using the registration method, the observers systematically detected the trap graft. Selections of the 3 best matching allografts performed using registration and template methods were different. Selection of the 3 best matching allografts was improved by the registration method. Finally, reproducibility of the selection was improved when using the registration method. INTERPRETATION: 3-D CT registration provides more useful information than the template method but the final decision lies with the surgeon, who should select the optimal allograft according to his or her own preferences and the needs of the recipient.


Assuntos
Transplante Ósseo/métodos , Imageamento Tridimensional/métodos , Ossos Pélvicos/transplante , Bancos de Ossos , Humanos , Tamanho do Órgão , Ossos Pélvicos/anatomia & histologia , Transplante Homólogo
12.
Sarcoma ; 2010: 125162, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21127723

RESUMO

Pelvic sarcoma is associated with a relatively poor prognosis, due to the difficulty in obtaining an adequate surgical margin given the complex pelvic anatomy. Magnetic resonance imaging and computerized tomography allow valuable surgical resection planning, but intraoperative localization remains hazardous. Surgical navigation systems could be of great benefit in surgical oncology, especially in difficult tumor location; however, no commercial surgical oncology software is currently available. A customized navigation software was developed and used to perform a synovial sarcoma resection and allograft reconstruction. The software permitted preoperative planning with defined target planes and intraoperative navigation with a free-hand saw blade. The allograft was cut according to the same planes. Histological examination revealed tumor-free resection margins. Allograft fitting to the pelvis of the patient was excellent and allowed stable osteosynthesis. We believe this to be the first case of combined computer-assisted tumor resection and reconstruction with an allograft.

13.
PLoS One ; 14(7): e0220016, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31318948

RESUMO

BACKGROUND: In 2015, an earthquake killing 9,000 and injuring 22,000 people hit Nepal. The Tribhuvan University Teaching Hospital (TUTH), a reference tertiary hospital, was operational immediately after the earthquake. We studied the profile of earthquake victims admitted in TUTH and assessed what factors could influence hospital length of stay. METHODS: An earthquake victim dataset was created based on patient records, with information on sex, age, date of admission and discharge, diagnosis, and surgical intervention. We performed an initial descriptive overview of the earthquake victims followed by a time-to-event analysis to compare length of hospital stay in different groups, using log rank test and cox regression to calculate Hazard Ratios. RESULTS: There were in total 501 admitted victims, with the peak of admissions occurring on the fifth day after the earthquake. About 89% had injury as main diagnosis, mostly in lower limbs, and 66% of all injuries were fractures. Nearly 69% of all patients underwent surgery. The median length of hospital stay was 10 days. Lower limb and trunk injuries had longer hospital stays than injuries in the head and neck (HR = 0.68, p = 0.009, and HR = 0.62 p = 0.005, respectively). Plastic surgeries had longer hospital stays than orthopaedic surgeries (HR = 0.57 p = 0.006). Having a crush injury and undergoing an amputation also increased time to discharge (HR = 0.57, p = 0.013, and HR = 0.65 p = 0.045 respectively). CONCLUSIONS: Hospital stay was particularly long in this sample in comparison to other studies on earthquake victims, indirectly indicating the high burden TUTH had to bear to treat these patients. To strengthen resilience, tertiary hospitals should have preparedness plans to cope with a large influx of injured patients after a large-scale disaster, in particular for the initial days when there is limited external aid.


Assuntos
Vítimas de Desastres/estatística & dados numéricos , Terremotos , Hospitalização , Centros de Atenção Terciária , Adolescente , Adulto , Criança , Pré-Escolar , Demografia , Vítimas de Desastres/história , Feminino , História do Século XXI , Humanos , Lactente , Recém-Nascido , Masculino , Prontuários Médicos , Pessoa de Meia-Idade , Nepal/epidemiologia , Modelos de Riscos Proporcionais , Adulto Jovem
14.
Gait Posture ; 28(4): 703-7, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18515109

RESUMO

Progressive spinal deformities, such as scoliosis, often need orthotic management to prevent deterioration. Such braces may alter spinal segmental movements, which contribute in minimizing energy requirements during gait. The goal of this study was to isolate the immediate effect of bracing on mechanical work and energy cost in 13 healthy subjects. Gait was assessed by a conventional motion analysis system. Our results showed a decrease in pelvis and shoulder motion, an increase in external work, and an alteration in pendulum-like mechanism of walking when wearing the brace. However, no significant difference was observed in total mechanical work, electromyographic activity and energy cost. The loss of efficiency of this pendulum mechanism could be due to the reduction of pelvis and shoulder motion brought about by the brace.


Assuntos
Metabolismo Energético , Marcha/fisiologia , Caminhada/fisiologia , Fenômenos Biomecânicos , Braquetes , Eletromiografia , Desenho de Equipamento , Feminino , Quadril/fisiologia , Humanos , Pelve/fisiologia , Ombro/fisiologia , Fatores de Tempo
15.
Acta Orthop ; 79(5): 695-702, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18839378

RESUMO

BACKGROUND AND PURPOSE: Osseous pelvic tumors can be resected and reconstructed using massive bone allografts. Geometric accuracy of the conventional surgical procedure has not yet been documented. The aim of this experimental study was mainly to assess accuracy of tumoral resection with a 10-mm surgical margin, and also to evaluate the geometry of the host-graft reconstruction. METHODS: An experimental model on plastic pelvises was designed to simulate tumor resection and reconstruction. 4 experienced surgeons were asked to resect 3 different tumors and to reconstruct pelvises. 24 resections and host-graft junctions were available for evaluation. Resection margins were measured. Several methods were created to evaluate geometric properties of the host-graft junction. RESULTS: The probability of a surgeon obtaining a 10-mm surgical margin with a 5-mm tolerance above or below, was 52% (95% CI: 37-67). Maximal gap, gap volume, and mean gap between host and graft was 3.3 (SD 1.9) mm, 2.7 (SD 2.1) cm3 and 3.2 (SD 2.1) mm, respectively. Correlation between these 3 reconstruction measures and the degree of contact at the host-graft junction was poor. INTERPRETATION: 4 experienced surgeons did not manage to consistently respect a fixed surgical margin under ideal working conditions. The complex 3-dimensional architecture of the pelvis would mainly explain this inaccuracy. Solutions to this might be to increase the surgical margin or to use computer- and robotic-assisted technologies in pelvic tumor resection. Furthermore, our attempt to evaluate geometry of the pelvic reconstruction using simple parameters was not satisfactory. We believe that there is a need to define new standards of evaluation.


Assuntos
Neoplasias Ósseas/cirurgia , Transplante Ósseo , Osteossarcoma/cirurgia , Neoplasias Pélvicas/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Competência Clínica , Simulação por Computador , Humanos , Modelos Anatômicos , Modelos Biológicos , Procedimentos de Cirurgia Plástica/normas
16.
Acta Orthop Belg ; 74(5): 623-6, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19058695

RESUMO

Prosthesis or allograft selection usually relies on comparison of templates with radiographs of the patient. Radiographic magnification must be evaluated accurately to select the optimal implant. Radiographic magnification was retrospectively assessed in 40 patients by reference to the pelvic height measured on computed tomography scans. Intra-subject variation of the magnification was calculated in 14 patients for whom two different pelvic radiographs were available. A wide range of magnification was observed (112% to 129%) as well as a substantial intra-subject variation (8%). Paired samples t-test showed a systematic error (p < 0.001) in using 110% and 115% as magnification whereas a similar error was not found when using 120%. Mean value for magnification was 119%. Radiographic magnification measurement can be made using the pelvic height method in patients who have undergone thoraco-abdominal, abdominal or pelvic computed tomography.


Assuntos
Pelve/diagnóstico por imagem , Ampliação Radiográfica , Tomografia Computadorizada por Raios X , Humanos , Estudos Retrospectivos
17.
Gait Posture ; 61: 141-148, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29353740

RESUMO

PURPOSE: To assess radiological and gait biomechanical changes before, at one and 10 years after surgery in AIS patients. METHODS: This clinical prospective study included fifteen adult women (mean[SD] age: 26 [1] years) diagnosed with thoraco-lumbar/lumbar AIS and operated 10 years ago. Clinical, radiological and gait variables, including kinematics, electromyography (EMG), mechanics and energetics were compared between presurgery (S0), 1 year (S1) and 10 years (S2) postsurgery period using a one way repeated measure ANOVA. RESULTS: The Cobb angle of the scoliosis curve was reduced by 55% at 1 year postsugery but only by 37% at 10 years postsurgery suggesting a loss of 32% over time. Frontal plumb line C7-S1 distance was significantly improved by surgery (-44%) and remained stable at 10 years postsurgery. Lower limb kinematics was not affected by the surgery at long term. Excessive bilateral activation of lombo-pelvic muscles, observed before surgery, decreased significantly at S1 and S2 period. Mechanical energy increased significantly between S0, S1 and S2 session, without any change for the energetic variables. CONCLUSIONS: Between 1 and 10 years post-surgery, thoraco-lumbar/lumbar AIS women showed a few decompensation of the curve without any change of the improved frontal body balance. Lower limbs and pelvic motion, during gait, was not affected by the surgery. But presurgical excessive EMG activity of the lumbo-pelvic muscle and reduced mechanical energy produced to walk get similar to normal patterns. Only the oxygen consumption remained excessive probably due to physical deconditioning or postural instability.


Assuntos
Previsões , Marcha/fisiologia , Vértebras Lombares/cirurgia , Músculo Esquelético/fisiopatologia , Escoliose/fisiopatologia , Fusão Vertebral , Caminhada/fisiologia , Adolescente , Adulto , Eletromiografia/métodos , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Escoliose/cirurgia , Adulto Jovem
18.
J Bone Joint Surg Am ; 89(3): 579-87, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17332107

RESUMO

BACKGROUND: Reconstruction of the pelvic arch after resection of a malignant pelvic tumor remains a major surgical challenge because of the high rate of associated complications. The purpose of this investigation was to assess the functional outcome and complication rate following treatment with a bone allograft to reconstruct the pelvis. METHODS: Twenty-four consecutive patients underwent excision of a malignant pelvic bone tumor and reconstruction with a pelvic bone allograft. The living patients were followed for a minimum of twenty-four months. There were nineteen primary malignant bone tumors, sixteen of which were high-grade sarcomas, and there were five isolated metastases. Patients were examined clinically and radiographically and were assessed functionally with the Musculoskeletal Tumor Society score. RESULTS: The mean age of the patients at the time of the index surgery was thirty-four years, and the mean duration of follow-up was forty-one months. Eighteen of the twenty-four resections involved the periacetabular area and were followed by reconstruction either with a hip prosthesis (thirteen) or with an osteochondral allograft alone (five). The six other resections involved the iliac bone. All patients received a massive bone allograft that had been sterilely procured without secondary irradiation. At the time of our last evaluation, eight patients were alive and free of disease. Seven patients had a local recurrence. Neurological deficits were present in six patients, and three had a deep infection. Nonunion of three of the sixteen allografts that could be evaluated was observed. Neither graft fracture nor lysis was observed. Eleven patients underwent surgical revision, with nine of these revisions related to the reconstruction. The average Musculoskeletal Tumor Society score at the time of the latest follow-up was 73% of the maximal possible score. The average score was 82% for the eleven patients with an age of less than twenty years at the time of the index procedure and 65% for the thirteen older patients. Ten patients walked without any assistive device, and five of them had normal function with no or only a slight limp. CONCLUSIONS: Pelvic reconstruction after a limb-sparing resection is associated with a high risk of surgical complications and usually should be reserved for patients with a primary bone sarcoma. A pelvic allograft can restore the anatomy and provide good functional results, especially in young patients. Nonunion was the most common allograft-related complication.


Assuntos
Neoplasias Ósseas/cirurgia , Transplante Ósseo/métodos , Procedimentos Ortopédicos/métodos , Ossos Pélvicos/cirurgia , Sarcoma/cirurgia , Adolescente , Adulto , Idoso , Perda Sanguínea Cirúrgica , Neoplasias Ósseas/mortalidade , Neoplasias Ósseas/terapia , Transplante Ósseo/diagnóstico por imagem , Criança , Terapia Combinada , Avaliação da Deficiência , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Ossos Pélvicos/patologia , Complicações Pós-Operatórias , Estudos Prospectivos , Radiografia , Sarcoma/mortalidade , Sarcoma/terapia , Transplante Homólogo , Resultado do Tratamento
19.
Interact Cardiovasc Thorac Surg ; 24(1): 90-98, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27659148

RESUMO

OBJECTIVES: Porcine small intestinal submucosa extracellular matrix (CorMatrix; CorMatrix Cardiovascular, Rosewell, GA) is a relatively novel tissue substitute used in cardiovascular applications. We investigated the biological reaction and remodelling of CorMatrix as a tri-leaflet valved conduit in a pig model. We hypothesized that CorMatrix maintains a durable architecture as a valved conduit and remodels to resemble surrounding tissues. METHODS: We fashioned the valved conduit using a 7 × 10 cm 4-ply CorMatrix sheet and placed it in the thoracic aorta of seven landrace pigs for 3, 4, 5 and 6 months. Biodegradation, replacement by native tissue, strength and durability were examined by histology, immunohistochemistry and mechanical testing. RESULTS: Four pigs, one per time frame, completed the study. The conduit lost its original architecture as a tri-leaflet valve due to cusp immobility, subsequent attachment to the wall segment and consequent maintenance of a thick arterial wall-like structure. Scaffold resorption was incomplete, with disorganized inconsistent spatial and temporal degradation even at 6 months. Fibrosis, scarring and calcification started at 4 months and chronic inflammation persisted. The partially remodelled scaffold did not resemble the aortic wall, suggesting impaired remodelling. Mechanical testing showed progressive weakening of the tissues over time, which were liable to breakage. CONCLUSIONS: CorMatrix is biodegradable; however, it failed to remodel in a structured and anatomical fashion in an arterial environment. Progressive mechanical and remodelling failure in this scenario might be explained by the complexity of the conduit design and the host's chronic inflammatory response, leading to early fibrosis and calcification.


Assuntos
Aorta Torácica/cirurgia , Bioprótese , Prótese Vascular , Matriz Extracelular , Animais , Calcinose/patologia , Estudos de Viabilidade , Fibrose , Inflamação/patologia , Modelos Animais , Suínos
20.
Biorheology ; 41(3-4): 349-58, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15299267

RESUMO

The subchondral bone has long been known to thicken in osteoarthritis. However, recent evidence has demonstrated that the turnover of the bone is increased several fold, and further suggests that the thickening occurs prior to degradation of the articular cartilage, indicating that it plays a role in the pathogenesis of osteoarthritis. The mechanical and biochemical properties of the subchondral bone are therefore of particular interest in any attempt to determine the nature of the factors initiating osteoarthritis. We have shown that the subchondral bone collagen of the femoral head possessed a 20-fold increase in turnover, as assessed by procollagen rate of synthesis and metalloproteinase degradation, and a 25% decrease in mineralisation. This increased metabolism and high lysyl hydroxylation leads to narrower and weaker fibres. Additionally the phenotypic expression of the osteoblasts is modified to produce increasing proportions of type I homotrimer in addition to the normal type I heterotrimer, which further reduces the mechanical strength of the bone. Overall, the narrow immature collagen fibres, the reduction in pyrrole cross-linking, decreased mineralisation, and increased amounts of type I homotrimer, all contribute to a weakening of the mechanical properties of the subchondral bone.


Assuntos
Remodelação Óssea , Osso e Ossos/fisiopatologia , Cartilagem , Osteoartrite/fisiopatologia , Fenômenos Biomecânicos , Densidade Óssea , Osso e Ossos/metabolismo , Colágeno/metabolismo , Cabeça do Fêmur , Humanos , Metaloproteases/metabolismo , Pró-Colágeno/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA