Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 25(3): 1116-1125, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36691737

RESUMO

AIMS: Permanent pacemaker implantation (PPM-I) remains nowadays the most important drawback of transcatheter aortic valve replacement (TAVR) procedure and the optimal strategy of delayed conduction disturbances (CDs) in these patients is unclear. The study aimed to validate an ambulatory electrocardiogram (ECG) monitoring through a 30 s spot ambulatory digital mobile ECG (AeECG), by using KardiaMobile-6L device in a 30-day period after TAVR procedure. METHODS AND RESULTS: Between March 2021 and February 2022, we consecutively enrolled all patients undergoing TAVR procedure, except pacemaker (PM) carriers. At discharge, all patients were provided of a KardiaMobile-6L device and a spot digital ECG (eECG) recording 1 month schedule. Clinical and follow-up data were collected, and eECG schedule compliance and recording quality were explored. Among 151 patients without pre-existing PM, 23 were excluded for pre-discharge PPM-I, 18 failed the KardiaMobile-6L training phase, and 10 refused the device. Delayed CDs with a Class I/IIa indication for PPM-I occurred in eight patients (median 6 days). Delayed PPM-I vs. non-delayed PPM-I patients were more likely to have longer PR and QRS intervals at discharge. PR interval at discharge was the only independent predictor for delayed PPM-I at multivariate analysis. The overall eECG schedule compliance was 96.5%. None clinical adverse events CDs related were documented using this new AeECG monitoring modality. CONCLUSION: A strategy of 30 s spot AeECG is safe and efficacious in delayed CDs monitoring after TAVR procedure with a very high eECG schedule level of compliance.


Assuntos
Estenose da Valva Aórtica , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estimulação Cardíaca Artificial/métodos , Resultado do Tratamento , Fatores de Risco , Doença do Sistema de Condução Cardíaco/etiologia , Eletrocardiografia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia
2.
Pacing Clin Electrophysiol ; 44(8): 1404-1412, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34224159

RESUMO

PURPOSE: To compare the outcome of paroxysmal atrial fibrillation (AF) ablation via pulmonary vein isolation using Ablation Index (AI) with strict or standard stability criteria. METHODS: We enrolled 130 consecutive naive patients affected by paroxysmal AF who underwent PVI at two high-volume centers. AI target was ≥380 at the posterior wall and ≥500 at the anterior wall. Strict versus standard stability criteria were set for Group 1 (65 patients) and Group 2 (65 patients), respectively. We compared those strategies with a historical cohort of 72 consecutive patients treated at same centers in the VISITALY study, using average force ≥10 g and strict stability criteria as target parameters. Interlesion distance target was <6 mm. Recurrence was defined as any AF, atrial tachycardia (AT) or atrial flutter (AFL) during the 12 months after ablation, excluding a 90-days blanking period. RESULTS: Procedure duration (224.05 ± 47.21 vs. 175.61 ± 51.29 min; p < .001), fluoroscopy time (11.85 ± 4.38 vs. 10.46 ± 6.49 min; p = .019) and pericardial effusion rate (9.23% vs. 0%; p = .01) were higher in Group 1 than in Group 2. Freedom from AF/AT/AFL at 12 months was not significantly different (Group 1: 86.15%; Group 2: 90.77%; p = .42). Compared to VISITALY study, there were not significant differences in terms of recurrences. CONCLUSION: A strategy of PVI using AI with standard stability criteria performed the best in terms of procedure efficiency and safety. Twelve-months arrhythmia-free survival rate was comparable with other strategies pursuing an interlesion distance target <6 mm, regardless of the use of AI.


Assuntos
Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Ablação por Radiofrequência/normas , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Estudos Retrospectivos
3.
Europace ; 22(9): 1401-1408, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32681177

RESUMO

AIMS: Optimal management of redundant or malfunctioning leads is controversial. We aimed to assess safety and efficacy of mechanical transvenous lead extraction (TLE) in patients with abandoned leads. METHODS AND RESULTS: Consecutive TLE procedures performed in our centre from January 2009 to December 2017 were considered. We evaluated the safety and efficacy of mechanical TLE in patients with abandoned (Group 1) compared to non-abandoned (Group 2) leads. We analysed 1210 consecutive patients that required transvenous removal of 2343 leads. Group 1 accounted for 250 patients (21%) with a total of 617 abandoned leads (26%). Group 2 comprised 960 patients (79%) with 1726 leads (74%). The total number of leads (3.0 vs. 2.0), dwelling time of the oldest lead (108.00 months vs. 60.00 months) and infectious indications for TLE were higher in Group 1. Clinical success was achieved in 1168 patients (96.5%) with a lower rate in Group 1 (90.4% vs. 98.1%; P < 0.001). Major complications occurred in only 9 patients (0.7%), without significant differences among the two groups. The presence of one or more abandoned leads [odds ratio (OR) 3.47; 95% confidence interval (CI) 1.07-11.19; P = 0.037] and dwelling time of the oldest lead (OR 1.01 for a month; 95% CI 1.01-1.02; P < 0.001) were associated with a higher risk of clinical failure. CONCLUSION: Transvenous mechanical lead extraction is a safe procedure also in high-risk settings, as patients with abandoned leads. Success rate resulted a bit lower, especially in the presence of abandoned leads with long implantation time.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo , Marca-Passo Artificial , Falha de Equipamento , Humanos , Razão de Chances , Estudos Retrospectivos , Resultado do Tratamento
4.
Pacing Clin Electrophysiol ; 43(4): 382-387, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32144936

RESUMO

BACKGROUND: Managing elderly patients with infection or malfunction deriving from a cardiac implantable electronic device (CIED) may be challenging. The aim of this study was to evaluate safety and efficacy of mechanical transvenous lead extraction (TLE) in elderly patients. METHODS: Patients who had undergone TLE in single tertiary referral center were divided in two groups (group 1: ≥ 80 years; group 2: < 80 years) and their acute and chronic outcomes were compared. All patients were treated with manual traction or mechanical dilatation. RESULTS: Our analysis included 1316 patients (group 1: 202; group 2: 1114 patients), with a total of 2513 leads extracted. Group 1 presented more comorbidities, more pacemakers than implantable cardioverter-defibrillators, whereas the dwelling time of the oldest lead and the number of leads were similar, irrespective of patient's age. In group 1, the radiological success rate for lead was higher (99.0% vs 95.9%; P < .001) and the fluoroscopy time lower (13.0 vs 15.0 min; P = .04) than in group 2. Clinical success was reached in 1273 patients (96.7%), without significant differences between groups (group 1: 98.0% vs group 2: 96.4%; P = .36). Major complications occurred in 10 patients (0.7%) without significative differences between patients with more or less than 80 years (group 1: 1.5% vs group 2: 0.6%; P = .24) and with no procedure-related deaths in elderly group. CONCLUSIONS: Mechanical TLE in elderly patients is a safe and effective procedure. In the over-80s, a comparable incidence of major complications with younger patients was observed, with at least a similar efficacy of the procedure.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo/métodos , Marca-Passo Artificial , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Remoção de Dispositivo/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Resultado do Tratamento
5.
Monaldi Arch Chest Dis ; 90(4)2020 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-33238697

RESUMO

Rates of cardiac pacemaker implantation rise with age, and, meanwhile, elderly patient may be at great risk of complications, as pneumothorax, lead perforation, or pocket dehiscence. The use of leadless pacemaker could overcome peri- and post-procedural complications related to the presence of transvenous leads and pocket. The study aims to investigate feasibility and outcomes of Micra Transcatheter Pacing System (M-TPS) implantation in elderly, which represents a challenge for conventional cardiac pacing. Between May 2014 and July 2019, 109 patients (88 males, mean age 77.71±9.68 years) underwent M-TPS implantation at our Center, targeting a non-apical site of delivery when feasible. Study population was divided into two groups according to age (group 1 <79 years vs group 2 group 2 ≥80 years). The outcome evaluation included electrical performance at hospital discharge, and during follow-up. In 46/109 cases (34 males, 73.91%) M-TPS was implanted in patients older than 80 years. There were no statistically significant differences between groups for demographics characteristics, except for age. The procedure was performed via the right femoral access in 102/109 cases and was successful in all cases, with no device-related events. No differences were observed between groups in procedure duration, single device delivery, electrical performance at implant and at 12 month F-U. MTP-S implant is an effective and safe procedure in elderly patients, with similar electrical performance and outcome compared with younger patients at mid-term follow-up.


Assuntos
Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco , Desenho de Equipamento , Humanos , Masculino , Resultado do Tratamento
6.
Europace ; 21(1): 114-120, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-29893837

RESUMO

AIMS: To demonstrate the feasibility and long-term performances of a non-apical Micra pacemaker implantation. METHODS AND RESULTS: Fifty-two consecutive patients underwent Micra implantation, targeting a non-apical site of delivery when feasible. Each patient received a regular follow-up (mean 13 ± 9 months). The first 17 patients were also enrolled in the Micra transcatheter pacing system trial (Group 1); the remaining ones presented broader indications and included post-extraction subjects (Group 2). In 19 of 52 patients (Group 1: 6%, Group 2: 51%; P = 0.002) Micra was implanted because of high-risk characteristics that discouraged the implantation of a traditional pacemaker. In 31 of 52 patients (60%) Micra was implanted in a non-apical location, with a lower rate of single delivery compared with apical sites (48% vs. 81%, P = 0.035), but without any impact on electrical performance. Pacing threshold remained optimal in the majority of patients (94%), regardless of the site of implantation (apical vs. non-apical location: 0.50 vs. 0.52 V/0.24 ms; P = 0.856) and group membership, with only 6% of the subjects showing elevated values (mean 1.92 ± 0.92 V/0.24 ms) at the last follow-up. No device-related adverse events were registered. CONCLUSION: Micra pacemaker implant is a safe and effective procedure even in a real life cohort of high-risk patients. A non-apical site of implantation is feasible in the majority of patients allowing stable electrical performance at long-term follow-up.


Assuntos
Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial , Marca-Passo Artificial , Potenciais de Ação , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento
7.
Europace ; 21(8): 1229-1236, 2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-31180481

RESUMO

AIMS: We aimed at investigating the feasibility and outcome of Micra implant in patients who have previously undergone transvenous lead extraction (TLE), in comparison to naïve patients implanted with the same device. METHODS AND RESULTS: Eighty-three patients (65 males, 78.31%; 77.27 ± 9.96 years) underwent Micra implant at our centre. The entire cohort was divided between 'post-extraction' (Group 1) and naïve patients (Group 2). In 23 of 83 patients (20 males, 86.96%; 73.83 ± 10.29 years), Micra was implanted after TLE. Indication to TLE was an infection in 15 patients (65.21%), leads malfunction in four (17.39%), superior vena cava syndrome in three (13.05%), and severe tricuspid regurgitation in one case (4.35%). The implant procedure was successful in all patients and no device-related events occurred at follow-up (median: 18 months; interquartile range: 1-24). No differences were observed between groups in fluoroscopy time (13.88 ± 10.98 min vs. 13.15 ± 6.64 min, P = 0.45), single device delivery (Group 1 vs. Group 2: 69.56% vs. 55%, P = 0.22), electrical performance at implant and at 12-month follow-up (Group 1 vs. Group 2: pacing threshold 0.48 ± 0.05 V/0.24 ms vs. 0.56 ± 0.25 V/0.24 ms, P = 0.70; impedance 640 ± 148.83 Ohm vs. 583.43 ± 99.7 Ohm, P = 0.27; and R wave amplitude 10.33 ± 2.88 mV vs. 12.62 ± 5.31 mV, P = 0.40). A non-apical site of implant was achievable in the majority of cases (72.3%) without differences among groups (78.26% vs. 70%; P = 0.42). CONCLUSION: Micra implant is an effective and safe procedure in patients still requiring a ventricular pacing after TLE, with similar electrical performance and outcome compared with naïve patients at long-term follow-up.


Assuntos
Estimulação Cardíaca Artificial , Microeletrodos , Marca-Passo Artificial , Implantação de Prótese/efeitos adversos , Infecções Relacionadas à Prótese , Idoso , Cateteres Cardíacos/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Estimulação Cardíaca Artificial/estatística & dados numéricos , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Itália/epidemiologia , Masculino , Avaliação de Processos e Resultados em Cuidados de Saúde , Marca-Passo Artificial/efeitos adversos , Marca-Passo Artificial/estatística & dados numéricos , Implantação de Prótese/instrumentação , Implantação de Prótese/métodos , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/cirurgia , Reoperação/efeitos adversos , Reoperação/métodos , Tempo
8.
Mycopathologia ; 181(3-4): 297-303, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26588923

RESUMO

BACKGROUND: Trichoderma species are saprophytic filamentous fungi producing localized and invasive infections that are cause of morbidity and mortality, especially in immunocompromised patients, causing up to 53% mortality. Non-immunocompromised patients, undergoing continuous ambulatory peritoneal dialysis, are other targets of this fungus. Current molecular diagnostic tools, based on the barcode marker ITS, fail to discriminate these fungi at the species level, further increasing the difficulty associated with these infections and their generally poor prognosis. CASE REPORT: We report on the first case of endocarditis infection caused by Trichoderma longibrachiatum in a 30-year-old man. This patient underwent the implantation of an implantable cardioverter defibrillator in 2006, replaced in 2012. Two years later, the patient developed fever, treated successfully with amoxicillin followed by ciprofloxacin, but an echocardiogram showed large vegetation onto the ventricular lead. After CIED extraction, the patient had high-grade fever. The culturing of the catheter tip was positive only in samples deriving from sonication according to the 2014 ESCMID guidelines, whereas the simple washing failed to remove the biofilm cells from the plastic surface. Subsequent molecular (ITS sequencing) and microbiological (macromorphology) analyses showed that the vegetation was due to T. longibrachiatum. CONCLUSIONS: This report showed that T. longibrachiatum is an effective threat and that sonication is necessary for the culturing of vegetations from plastic surfaces. Limitations of the current barcode marker ITS, and the long procedures required by a multistep approach, call for the development of rapid monophasic tests.


Assuntos
Antifúngicos/uso terapêutico , Biofilmes/efeitos dos fármacos , Desfibriladores Implantáveis/efeitos adversos , Endocardite/tratamento farmacológico , Coração/microbiologia , Micoses/tratamento farmacológico , Trichoderma/efeitos dos fármacos , Adulto , Anfotericina B/uso terapêutico , Sequência de Bases , DNA Intergênico/genética , Endocardite/microbiologia , Humanos , Masculino , Micoses/microbiologia , Análise de Sequência de DNA , Trichoderma/classificação , Trichoderma/genética , Voriconazol/uso terapêutico
9.
Echocardiography ; 32(10): 1463-70, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25865022

RESUMO

BACKGROUND: We prospectively assessed the incremental value of a pocket-sized echocardiography (PSE) device during cardiology consultations, in addition to physical examination, ECG reading, and chest x-ray. METHODS: A total of 443 consecutive patients (53% men), referred for bedside consultations, underwent physical examination, ECG, and CXR, followed by PSE examination. The physician completed a detailed questionnaire (clinical and echocardiographic data, scanning time, abnormal results). Receiver operating characteristic (ROC) curve analysis was generated to test the predictive discrimination value of the different methods. The incremental value of PSE examination compared to clinical visit alone or combined with ECG results was expressed as a global chi-square value. RESULTS: The PSE examination did not influence the definitive diagnosis in only 23.5% of cases, while 25.3% of the diagnoses were confirmed and verified by PSE. The clinical diagnosis was enriched by PSE in 21.9% of cases, and the diagnosis was changed in 26.2%. The area under curve (AUC) of physical examination + ECG results (sensitivity: 80%; specificity: 67%) was significantly higher than physical examination alone (sensitivity: 75%; specificity: 62%) (P < 0.0002), and the AUC of PSE results (sensitivity: 88%; specificity: 86%) was significantly higher than physical examination + ECG results (P < 0.0001). The PSE results, combined with clinical and ECG results, had a significant incremental diagnostic value during cardiology consultation when compared to the clinical visit alone or with ECG results (P < 0.0001). CONCLUSIONS: PSE had an incremental diagnostic value during bedside cardiology consultation, increasing the number of appropriate diagnoses and reducing the routine use of echocardiography.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Ecocardiografia/instrumentação , Exame Físico , Sistemas Automatizados de Assistência Junto ao Leito , Idoso , Eletrocardiografia , Feminino , Humanos , Itália , Masculino , Estudos Prospectivos , Radiografia Torácica , Sensibilidade e Especificidade , Inquéritos e Questionários
10.
Telemed J E Health ; 21(1): 24-35, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25495564

RESUMO

INTRODUCTION: The digital divide affecting elderly patients may compromise the diffusion of telemedicine systems for this age segment. It might be that the difficulties in the passage from trials to the effective distribution of telemedicine systems are also due to the awareness of a personal digital divide in the target population. MATERIALS AND METHODS: The analysis aims to estimate the number of people over the age of 50 years with potential cardiovascular problems able to access the Web. It made use of data from several sources (the Survey of Health, Ageing and Retirement in Europe and the Istituto Nazionale di Statistica Multiscopo Survey). Furthermore, with regard to Italy, the estimates obtained from official data were compared with those obtained in a survey investigating heart failure patients in Tuscany. RESULTS: In 2011, the percentage of people suffering from cardiovascular diseases and with Web access was 24% in Europe, with significant differences by country (ranging from 53% in Switzerland to below 20% in Italy, Spain, and Portugal). In Italy, however, the proportion of people with Web access increased from 2007 to 2011, and the survey in Tuscany showed that elderly people with limited information and communications technology skills overcame challenges and learned how to connect to the Web because they started to appreciate new technologies. CONCLUSIONS: The opportunity to use the Internet to monitor patients with chronic disease can serve as a challenge to reduce the digital divide gap and, furthermore, to increase their social and technological inclusion.


Assuntos
Doenças Cardiovasculares/epidemiologia , Exclusão Digital , Internet , Telemedicina/instrumentação , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Envelhecimento , Europa (Continente) , Feminino , Insuficiência Cardíaca/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade
11.
Heart Rhythm ; 21(7): 1032-1039, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38403236

RESUMO

BACKGROUND: Epicardial access is often crucial for successful ventricular tachycardia (VT) ablation, but it is often burdened by significant procedural risk. Intentional coronary vein exit and intrapericardial CO2 insufflation (EpiCO2) can facilitate subxiphoid pericardial access. OBJECTIVE: This prospective study aimed to assess procedural feasibility, safety, and impact of the introduction of intrapericardial CO2 insufflation for epicardial access in a referral center for VT ablation. METHODS: All consecutive patients treated with epicardial VT ablation between November 2022 and January 2024 with the EpiCO2 technique at Pisa University Hospital were prospectively enrolled and compared in terms of feasibility, efficiency, and safety with a local retrospective cohort of patients treated with subxiphoid dry puncture between July 2018 and October 2022. RESULTS: Twenty-two consecutive patients (90.9% male; mean age, 54.3 years) underwent VT ablation with EpiCO2 during the study period. Epicardial access was achieved in all patients; median time from coronary sinus (CS) cannulation to epicardial access was 33 minutes. Intentional vein exit was successful in all cases, whereas CO2 insufflation was not feasible in 1 patient. There were no major complications and no significant bleeding. Since EpiCO2 introduction, epicardial approach utilization increased from 17.8% to 40% of all VT procedures. Comparison with 20 standard dry approach epicardial ablations showed no significant differences in terms of total procedural duration (322.5 [interquartile range, 296.75-363.75] minutes vs 359 [interquartile range, 323-409] minutes; P = .08). CONCLUSION: In our single-center experience, EpiCO2 was feasible and safe and led to significant increase in procedural volume without affecting total procedural time compared with standard dry puncture.


Assuntos
Dióxido de Carbono , Ablação por Cateter , Estudos de Viabilidade , Insuflação , Pericárdio , Taquicardia Ventricular , Humanos , Masculino , Feminino , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/fisiopatologia , Pessoa de Meia-Idade , Insuflação/métodos , Dióxido de Carbono/administração & dosagem , Ablação por Cateter/métodos , Pericárdio/cirurgia , Estudos Prospectivos , Encaminhamento e Consulta , Resultado do Tratamento , Seguimentos , Estudos Retrospectivos
12.
Echocardiography ; 30(7): 820-8, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23496202

RESUMO

BACKGROUND: In recent years, right ventricular (RV) function has acquired greater relevance as a clinical and prognostic marker in many physiopathological conditions. The study aims to point out the value of real time three-dimensional echocardiography (RT3DE) and tissue Doppler imaging (TDI) in the evaluation of patients affected by pulmonary hypertension (PH), compared with conventional two-dimensional (2D) echocardiography. METHODS: We enrolled 44 subjects affected by PH who underwent 2D and Doppler echocardiography, RT 3D Echocardiography and TDI evaluation of the RV, and a healthy control group. PH itself can induce severe functional and structural abnormalities of the RV, such as RV hypertrophy, RV dilation, and RV systolic and diastolic dysfunction. RESULTS: In this study, RV FAC, and TAPSE showed marked alterations in patients with PH compared to the control group (C): (RVFAC: [PH] 0.29 ± 0.07 vs. [C] 0.49 ± 0.05%, P < 0.0001; TAPSE: [PH] 15.3 ± 3.2 vs. [C] 21.1 ± 2.6 mm, P > 0.0001). The 3D RV end-diastolic volume was significantly higher in PH than in C (PH) (138.7 ± 25.3 vs. [C] 82.8 ± 12.5 mL, P < 0.0001] as well as 3D RV end-systolic volume (PH) (97.6 ± 21.5 vs. [C] 39.3 ± 9.5 mL, P < 0.0001). The 3D RV ejection fraction (EF) was significantly lower in the pulmonary hypertension group than in healthy subjects (31.8 ± 6.8 vs. [C] 52.5 ± 4.7%, P < 0.0001). CONCLUSIONS: In patients with PH, evaluation of the RV diastolic and systolic volume and EF by RT3DE has shown a higher discriminating power in comparison, respectively, with 2DRV diastolic area and the relative fractional area changes.


Assuntos
Ecocardiografia Tridimensional/métodos , Hipertensão Pulmonar/diagnóstico por imagem , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Direita/diagnóstico por imagem , Sistemas Computacionais , Feminino , Humanos , Hipertensão Pulmonar/complicações , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Direita/complicações
13.
J Clin Med ; 12(15)2023 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-37568387

RESUMO

High-power short-duration (HPSD) ablation is an increasingly used ablation strategy for pulmonary vein isolation (PVI) procedures, but Lesion Index (LSI)-guided HPSD radiofrequency (RF) applications have not been described in this clinical setting. We evaluated the procedural efficiency and safety of an LSI-guided HPSD strategy for atrial fibrillation (AF) ablation. Paroxysmal and persistent AF patients scheduled for AF ablation were prospectively enrolled and divided into two groups, according to the ablation power used (≥45 W for the LSI-HP Group and ≤40 W for the LSI-LP group). All patients underwent only PVI LSI-guided ablation (5.5 to 6 anteriorly; 5 to 5.5 superiorly, 4.5 to 5 posteriorly) with a point-by-point strategy and an inter-lesion distance <6 mm. Forty-six patients with AF (25 in the LSI-HP Group vs 21 in the LSI-LP Group)-59% paroxysmal, 78% male, with low-intermediate CHA2DS2-Vasc scores (2 [1-3]), a preserved ejection fraction (65 ± 6%) and a mean left atrial index volume of 39 ± 13 mL/m2 were prospectively enrolled. Baseline clinical characteristics were comparable between groups. PVI was successful in all patients. The RF time (29 (23-37) vs. 49 (41-53) min, p < 0.001), total procedure time (131 (126-145) vs. 155 (139-203) min, p = 0.007) and fluoroscopy time (12 (10-18) vs. 21 (16-26) min, p = 0.001) were significantly lower in the LSI-HP Group. No complications or steam pops were seen in either group. LSI-HP AF ablation significantly improved procedural efficiency-reducing ablation time, total procedural duration, and fluoroscopy use, while maintaining a comparable safety profile to lower-power procedures.

14.
J Clin Med ; 12(6)2023 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-36983388

RESUMO

INTRODUCTION: Transcatheter atrial fibrillation (AF) ablation is still carried out with continuous invasive radial arterial blood pressure (IBP) monitoring in many centers. Continuous noninvasive blood pressure (CNBP) measurement using the volume-clamp method is a noninvasive alternative method used in ICU. No data on CNBP reliability are available in the electrophysiology lab during AF ablation, where rhythm variations are common. BACKGROUND: The objective of the present study was to compare continuous noninvasive arterial pressure measured with the ClearSight device (Edwards Lifesciences, Irvine, CA, USA) with invasive radial artery pressure used as the reference method during AF ablation. METHODS: We prospectively enrolled 55 consecutive patients (age 62 ± 11 years, 80% male) undergoing transcatheter AF ablation (62% paroxysmal, 38% persistent) at our center. Standard of care IBP monitoring via a radial cannula and a contralateral noninvasive finger volume-clamp CNBP measurement device were positioned simultaneously in all patients for the entire procedure. Bland-Altman analysis was used to analyze the agreement between the two techniques. RESULTS: A total of 1219 paired measurements for systolic, diastolic, and mean arterial pressure were obtained in 55 subjects, with a mean (SD) of 22 (9) measurements per patient. The mean bias (SD) was -12.97 (13.89) mmHg for systolic pressure (level of agreement -14.24-40.20; correlation coefficient 0.84), -1.85 (8.52) mmHg for diastolic pressure (level of agreement -18.54-14.84; correlation coefficient 0.77) and 2.31 (8.75) mmHg for mean pressure (level of agreement -14.84-19.46; correlation coefficient 0.85). CONCLUSION: In patients undergoing AF ablation, CNBP monitoring with the ClearSight device showed acceptable agreement with IBP monitoring. Larger studies are needed to confirm the potential clinical implications of continuous noninvasive BP monitoring during AF ablation.

15.
Heart Rhythm O2 ; 4(10): 625-631, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37936665

RESUMO

Background: Existing data on the impact of sex differences on transvenous lead extraction (TLE) outcomes in cardiac device patients are limited. Objective: The purpose of this study was to evaluate the safety and efficacy of mechanical TLE in female patients. Methods: A retrospective evaluation was performed on 3051 TLE patients (group 1: female; group 2: male) from a single tertiary referral center. All individuals received treatment using single sheath mechanical dilation and various venous approaches as required. Results: Our analysis included 3051 patients (group 1: 750; group 2: 2301), with a total of 5515 leads handled with removal. Female patients were younger, had a higher left ventricular ejection fraction, and lower prevalences of coronary artery disease and diabetes mellitus. Infection was more common in male patients, whereas lead malfunction or abandonment were more frequent in female patients. Radiologic success was lower in female patients (95.8% vs 97.5%; P = .003), but there was no significant difference in clinical success between groups (97.2% vs 97.5%; P = .872). However, major complications (1.33% vs 0.60%; P <.001) and procedural mortality (0.4% vs 0.1%; P <.001) were higher in females compared to male patients. After multivariate analysis, female sex emerged as the only predictor of major complications, including deaths (odds ratio 3.96; 95% confidence interval 1.39-11.24). Conclusion: TLE using unpowered simple mechanical sheaths in female patients is safe and effective, but is associated with lower radiologic success and higher complication rates and mortality than in males. This finding underscores the importance of recognizing sex differences in TLE outcomes.

16.
J Cardiovasc Echogr ; 33(1): 1-9, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37426716

RESUMO

Background: The Italian Society of Echocardiography and Cardiovascular Imaging (SIECVI) conducted a national survey to understand better how different echocardiographic modalities are used and accessed in Italy. Methods: We analyzed echocardiography laboratory activities over a month (November 2022). Data were retrieved via an electronic survey based on a structured questionnaire, uploaded on the SIECVI website. Results: Data were obtained from 228 echocardiographic laboratories: 112 centers (49%) in the northern, 43 centers (19%) in the central, and 73 (32%) in the southern regions. During the month of observation, we collected 101,050 transthoracic echocardiography (TTE) examinations performed in all centers. As concern other modalities there were performed 5497 transesophageal echocardiography (TEE) examinations in 161/228 centers (71%); 4057 stress echocardiography (SE) examinations in 179/228 centers (79%); and examinations with ultrasound contrast agents (UCAs) in 151/228 centers (66%). We did not find significant regional variations between the different modalities. The usage of picture archiving and communication system (PACS) was significantly higher in the northern (84%) versus central (49%) and southern (45%) centers (P < 0.001). Lung ultrasound (LUS) was performed in 154 centers (66%), without difference between cardiology and noncardiology centers. The evaluation of left ventricular (LV) ejection fraction was evaluated mainly using the qualitative method in 223 centers (94%), occasionally with the Simpson method in 193 centers (85%), and with selective use of the three-dimensional (3D) method in only 23 centers (10%). 3D TTE was present in 137 centers (70%), and 3D TEE in all centers where TEE was done (71%). The assessment of LV diastolic function was done routinely in 80% of the centers. Right ventricular function was evaluated using tricuspid annular plane systolic excursion in all centers, using tricuspid valve annular systolic velocity by tissue Doppler imaging in 53% of the centers, and using fractional area change in 33% of the centers. When we divided into cardiology (179, 78%) and noncardiology (49, 22%) centers, we found significant differences in the SE (93% vs. 26%, P < 0.001), TEE (85% vs. 18%), UCA (67% vs. 43%, P < 0001), and STE (87% vs. 20%, P < 0.001). The incidence of LUS evaluation was similar between the cardiology and noncardiology centers (69% vs. 61%, P = NS). Conclusions: This nationwide survey demonstrated that digital infrastructures and advanced echocardiography modalities, such as 3D and STE, are widely available in Italy with a notable diffuse uptake of LUS in the core TTE examination, a suboptimal diffusion of PACS recording, and conservative use of UCA, 3D, and strain. There are significant differences between northern and central-southern regions and echocardiographic laboratories that pertain to the cardiac unit. This inhomogeneous distribution of technology represents one of the main issues that must be solved to standardize the practice of echocardiography.

17.
J Cardiovasc Echogr ; 33(3): 125-132, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38161775

RESUMO

Background: The Italian Society of Echography and Cardiovascular Imaging (SIECVI) conducted a national survey to understand the volumes of activity, modalities and stressors used during stress echocardiography (SE) in Italy. Methods: We analyzed echocardiography laboratory activities over a month (November 2022). Data were retrieved through an electronic survey based on a structured questionnaire, uploaded on the SIECVI website. Results: Data were obtained from 228 echocardiographic laboratories, and SE examinations were performed in 179 centers (80.6%): 87 centers (47.5%) were in the northern regions of Italy, 33 centers (18.4%) were in the central regions, and 61 (34.1%) in the southern regions. We annotated a total of 4057 SE. We divided the SE centers into three groups, according to the numbers of SE performed: <10 SE (low-volume activity, 40 centers), between 10 and 39 SE (moderate volume activity, 102 centers) and ≥40 SE (high volume activity, 37 centers). Dipyridamole was used in 139 centers (77.6%); exercise in 120 centers (67.0%); dobutamine in 153 centers (85.4%); pacing in 37 centers (21.1%); and adenosine in 7 centers (4.0%). We found a significant difference between the stressors used and volume of activity of the centers, with a progressive increase in the prevalence of number of stressors from low to high volume activity (P = 0.033). The traditional evaluation of regional wall motion of the left ventricle was performed in all centers, with combined assessment of coronary flow velocity reserve (CFVR) in 90 centers (50.3%): there was a significant difference in the centers with different volume of SE activity: the incidence of analysis of CFVR was significantly higher in high volume centers compared to low - moderate - volume (32.5%, 41.0% and 73.0%, respectively, P < 0.001). The lung ultrasound (LUS) was assessed in 67 centers (37.4%). Furthermore for LUS, we found a significant difference in the centers with different volume of SE activity: significantly higher in high volume centers compared to low - moderate - volume (25.0%, 35.3% and 56.8%, respectively, P < 0.001). Conclusions: This nationwide survey demonstrated that SE was significantly widespread and practiced throughout Italy. In addition to the traditional indication to coronary artery disease based on regional wall motion analysis, other indications are emerging with an increase in the use of LUS and CFVR, especially in high-volume centers.

19.
J Cardiol Cases ; 25(5): 272-274, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35582080

RESUMO

A 63-year-old man with hypertension and 3-vessel coronary artery disease previously treated with coronary artery bypass graft was admitted to our emergency room complaining of chest pain. He had undergone pacemaker implant 5 months before due to paroxysmal advanced atrioventricular block. Electrocardiography and troponin testing were unremarkable. Echocardiography and chest X-ray ruled out lead displacement and perforation. Interrogation showed normal parameters [right atrium: impedance 550 Ohm bipolar, sensing 2.4 mV bipolar; threshold 0.50 V/0.4 ms bipolar; right ventricle (RV): impedance 580 Ohm bipolar, sensing > 25 mV bipolar; threshold 1.5 V/0.4 ms bipolar and 0.4 V/0.4 ms unipolar]. Pain was evoked only during RV pacing. An electrophysiology study demonstrated painful RV pacing from multiple sites. We hypothesized that pain was associated with pacing-induced dyssynchrony. His-bundle pacing (HBP) was considered as a solution. We achieved HBP with a bipolar fixed-screw catheter connected to a cardiac resynchronization therapy pacemaker generator. During HBP above threshold (4.00 V/1.00 ms) the patient did not complain of any pain. He was discharged 3 days later pain-free with His-bundle lead amplitude set at 5.00 V/1.00 ms. After 6 months the patient was asymptomatic, with the device showing normal functioning. This is the first clinical experience of painful RV pacing treated with HBP. .

20.
J Interv Card Electrophysiol ; 64(3): 773-781, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35277775

RESUMO

BACKGROUND: The study aimed to explore the resolution of left atrial and left atrial appendage (LAA) spontaneous echo-contrast or thrombus in patients with nonvalvular atrial fibrillation/flutter (AF/AFL) under chronic oral anticoagulation (OAC). METHODS: A single-center retrospective analysis of patients who underwent a transesophageal echocardiography (TOE) for an electrical cardioversion was conducted. RESULTS: Among 277 TOE performed, 73 cases (26%) of LAA echo-contrast or thrombus were detected, 53 patients with LAA/LA echo-contrast (19%) and 20 (7%) with a thrombus. All patients were under chronic anticoagulation with a VKA (65%) or with a NOAC (35%). The Echo-contrast Group maintained the same OAC strategy in 49 patients (93%). The Thrombus Group kept the same OAC strategy with a NOAC in 6 cases (30%) and changed the strategy in 14 patients (70%), titrating NOAC dose in 1 (5%) and the VKA dose in 4 (20%) and switching from NOAC to VKA in 5 (25%), from VKA to NOAC in 3 (15%), and from NOAC to NOAC in 1 (5%). Smoke resolution was observed in 4/40 cases (10%) of the smoke group and thrombus resolution in 8/15 (53%) of the thrombus group. Patients with thrombus resolution had a lower CHA2DS2-Vasc score (3.5 ± 2 vs 4 ± 1, p = 0.05), were more often under NOAC (37.5 vs 28%, p = 0.07), and had a longer anticoagulation time (7.5 vs 4 months, p = 0.08). CONCLUSION (S): Changing OAC strategy is associated with thrombus resolution in more than 50% of chronically anticoagulated patients.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cardiopatias , Trombose , Anticoagulantes , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/tratamento farmacológico , Ecocardiografia Transesofagiana , Humanos , Estudos Retrospectivos , Fumaça , Trombose/complicações , Trombose/diagnóstico por imagem , Trombose/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA