Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 35(1): 155-161, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38010993

RESUMO

INTRODUCTION: The importance of atrio-ventricular synchrony pacing in sinus rhythm patients is known. To identify patients in whom leadless pacemakers are able to guarantee this atrio-ventricular synchrony, we explored correlations among echocardiographic measures of left atrial (LA) size and function (doppler parameter and strain) with A4 amplitude in patients implanted with new generation Micra-AV device. METHODS: After implantation with Micra-AV system, patients underwent device interrogation to evaluate AV synchrony based on the sensing of atrial mechanics and echocardiographic exam to assess LA morphology and LA function. RESULTS: In the 21 studied patients (14 males, 72 ± 13 years), the A4 wave amplitude values inversely correlated with LA antero-posterior diameter, LA volume, LA contraction strain and LA conduit strain, while they were positively related with LA reservoir strain. DISCUSSION: Our results indicate a statistically significant relationship between morphological echocardiographic LA parameters and atrial contraction signal (A4), detected by leadless pacemakers and used to synchronize ventricular pacing with the atrium. Instantaneous LA function assessment obtained with LA strain provides incremental information over morphological parameters. LA strain evaluates atrial myocardial deformation during the whole cardiac cycle. We found higher value of A4 in patients that have grater absolute value of LAsr, LAscd and LAsct, that are simple and measurable parameters of LA functional capacity. CONCLUSION: Preimplant echocardiographic evaluation of the atrial contractility may be useful in predicting adequate A4 sensing and consequently a good atrio-ventricular synchrony pacing. Echocardiography LA strain study seems promising in Micra-AV patient selection.


Assuntos
Átrios do Coração , Marca-Passo Artificial , Masculino , Humanos , Átrios do Coração/diagnóstico por imagem , Ventrículos do Coração , Ecocardiografia , Arritmias Cardíacas
2.
Heart Fail Rev ; 29(2): 379-394, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37728751

RESUMO

Heart failure (HF) and chronic kidney disease (CKD) are two pathological conditions with a high prevalence in the general population. When they coexist in the same patient, a strict interplay between them is observed, such that patients affected require a clinical multidisciplinary and personalized management. The diagnosis of HF and CKD relies on signs and symptoms of the patient but several additional tools, such as blood-based biomarkers and imaging techniques, are needed to clarify and discriminate the main characteristics of these diseases. Improved survival due to new recommended drugs in HF has increasingly challenged physicians to manage patients with multiple diseases, especially in case of CKD. However, the safe administration of these drugs in patients with HF and CKD is often challenging. Knowing up to which values ​​of creatinine or renal clearance each drug can be administered is fundamental. With this review we sought to give an insight on this sizable and complex topic, in order to get clearer ideas and a more precise reference about the diagnostic assessment and therapeutic management of HF and CKD.


Assuntos
Insuficiência Cardíaca , Insuficiência Renal Crônica , Humanos , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/epidemiologia , Biomarcadores
3.
Pacing Clin Electrophysiol ; 47(2): 256-259, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37208974

RESUMO

INTRODUCTION: Micra AV Transcatheter Pacing System (TPS) represents an innovative second-generation leadless pacemaker which represents an effective alternative to conventional devices in selected cases. Intrinsic malfunctions of these devices are rare, requiring sometimes their retrieval. When performed in experienced centers, this procedure is safe. CASE PRESENTATION: We describe a case of sudden battery malfunction of a Micra AV TPS, which required the extraction and the placement of a new pacing system in the right ventricle. DISCUSSION: This case, which has never been reported, highlights the need to a careful fluoroscopic evaluation and the usefulness of remote monitoring.


Assuntos
Arritmias Cardíacas , Marca-Passo Artificial , Humanos , Resultado do Tratamento , Desenho de Equipamento , Marca-Passo Artificial/efeitos adversos , Estimulação Cardíaca Artificial
4.
Echocardiography ; 41(1): e15724, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38064288

RESUMO

BACKGROUND AND AIM: Our aim was to evaluate the fluoroscopy time (FT), procedure time (PT) safety and efficacy when using intracardiac echocardiography (ICE) in comparison to transesophageal echocardiography (TEE) guidance for transcatheter closure of Ostium Secundum Atrial Septal Defect (OS-ASD). METHOD: Ninety patients (n = 90) diagnosed with OS-ASD underwent transcatheter closure between March 2006 and October 2021. Fifty-seven patients were treated under ICE guidance, while 33 patients were treated under TEE guidance. RESULTS: Mean age was 43 ± 15 years and 42 ± 10 years in the ICE and TEE groups, respectively. The majority of patients had a centrally placed defect. Median FT was 8.40 min versus 11.70 min (p < .001) in the ICE group compared to the TEE group, respectively. Median PT was 43 min versus 94 min (p < .001) in the ICE group compared to the TEE group, respectively. Both ICE and TEE provided high quality images. All interventions were completed successfully, except for one patient in the ICE group who experienced a device migration, the development of atrial tachycardia in one patient and atrial fibrillation in two patients in the ICE group which spontaneously cardioverted. There were no other complications. CONCLUSION: This study on a consistent cohort of patients with OS-ASD undergoing percutaneous closure suggests that use of ICE is safe and efficacious. Compared to TEE, ICE demonstrated significantly shorter FT and PT, decreasing the entire duration of the procedure and x-ray exposure. No relevant differences were observed in terms of success rate and complications.


Assuntos
Fibrilação Atrial , Comunicação Interatrial , Humanos , Adulto , Pessoa de Meia-Idade , Ecocardiografia Transesofagiana/métodos , Cateterismo Cardíaco/métodos , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/cirurgia , Fluoroscopia , Resultado do Tratamento
5.
Telemed J E Health ; 30(5): 1499-1503, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38294864

RESUMO

Telemedicine and remote monitoring devices, including implantable loop recorders (ILR), are increasingly adopted in the cardiologic setting. These are valuable tools in the arrhythmic stratification of patients at risk of sudden cardiac death, providing a tailored therapeutic management to prevent lethal arrhythmias. We report a case of an asymptomatic 18-year-old boy with a family history of syncope and cardiac arrest, who had a diagnosis of Brugada syndrome with an inducible type 1 pattern and carrier of a missense mutation of the SCN5A gene. In light of the risk factors, although not recommended by current guidelines, we decided to proceed with the implantation of an ILR with remote monitoring service. A few months later, an episode of asymptomatic sustained polymorphic ventricular tachycardia was promptly observed by the remote monitoring, leading to a timely implantation of a subcutaneous cardiac implantable defibrillator.


Assuntos
Síndrome de Brugada , Desfibriladores Implantáveis , Telemedicina , Humanos , Masculino , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/genética , Síndrome de Brugada/terapia , Adolescente , Telemedicina/métodos , Medição de Risco/métodos , Canal de Sódio Disparado por Voltagem NAV1.5/genética , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Eletrocardiografia , Eletrocardiografia Ambulatorial/instrumentação , Eletrocardiografia Ambulatorial/métodos , Mutação de Sentido Incorreto , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia
6.
Curr Heart Fail Rep ; 20(6): 530-541, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37962749

RESUMO

PURPOSE OF REVIEW: Heart failure (HF) and erectile dysfunction (ED) are two common conditions that affect millions of men worldwide and impair their quality of life. ED is a frequent complication of HF, as well as a possible predictor of cardiovascular events and mortality. ED deserves more attention from clinicians and researchers. RECENT FINDINGS: The pathophysiology of ED in HF involves multiple factors, such as endothelial dysfunction, reduced cardiac output, neurohormonal activation, autonomic imbalance, oxidative stress, inflammation, and drug side effects. The diagnosis of ED in HF patients should be based on validated questionnaires or objective tests, as part of the routine cardiovascular risk assessment. The therapeutic management of ED in HF patients should be individualized and multidisciplinary, considering the patient's preferences, expectations, comorbidities, and potential drug interactions. The first-line pharmacological treatment for ED in HF patients with mild to moderate symptoms (NYHA class I-II) is phosphodiesterase type 5 inhibitors (PDE5Is), which improve both sexual function and cardiopulmonary parameters. PDE5Is are contraindicated in patients who use nitrates or nitric oxide donors for angina relief, and these patients should be advised to avoid sexual activity or to use alternative treatments for ED. Non-pharmacological treatments for ED, such as psychotherapy or couples therapy, should also be considered if there are significant psychosocial factors affecting the patient's sexual function or relationship. This review aims to summarize the most recent evidence regarding the prevalence of ED, the pathophysiology of this condition with an exhaustive analysis of factors involved in ED development in HF patients, a thorough discussion on diagnosis and management of ED in HF patients, providing practical recommendations for clinicians.


Assuntos
Disfunção Erétil , Insuficiência Cardíaca , Masculino , Humanos , Disfunção Erétil/epidemiologia , Disfunção Erétil/etiologia , Disfunção Erétil/terapia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/tratamento farmacológico , Qualidade de Vida , Inibidores da Fosfodiesterase 5/uso terapêutico , Medição de Risco
7.
J Clin Ultrasound ; 50(8): 1097-1109, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36218216

RESUMO

The diagnosis of acute myocarditis often involves several noninvasive techniques that can provide information regarding volumes, ejection fraction, and tissue characterization. In particular, echocardiography is extremely helpful for the evaluation of biventricular volumes, strain and ejection fraction. Cardiac magnetic resonance, beyond biventricular volumes, strain, and ejection fraction allows to characterize myocardial tissue providing information regarding edema, hyperemia, and fibrosis. Contemporary cardiac computed tomography angiography (CCTA) can not only be extremely important for the assessment of coronary arteries, pulmonary arteries and aorta but also tissue characterization using CCTA can be an additional tool that can explain chest pain with a diagnosis of myocarditis.


Assuntos
Miocardite , Ecocardiografia/métodos , Humanos , Imageamento por Ressonância Magnética/métodos , Miocardite/diagnóstico por imagem , Volume Sistólico , Função Ventricular Esquerda
8.
Cardiol Rev ; 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38602404

RESUMO

The association between cardiomyopathies (CMPs) and psychiatric disorders is a complex and bidirectional phenomenon that involves multiple mechanisms and factors. CMPs may raise the risk of psychiatric disorders due to the psychological stress, physical limitations, social isolation, or poor prognosis associated with the underlying disease. Psychiatric disorders, on the other hand, can increase the possibility of developing or worsening CMPs due to the behavioral, neuroendocrine, inflammatory, or pharmacological effects of mental illness or its treatment. Moreover, some common genetic or environmental factors may have a relevant influence on both conditions. With this comprehensive review, we sought to provide an overview of the current evidence on the strict and intriguing interconnection between CMPs and psychiatric disorders, focusing on the epidemiology, pathophysiology, clinical implications, and management strategies.

9.
J Clin Med ; 13(14)2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39064316

RESUMO

Historically, cardiovascular prevention has been predominantly focused on stress-induced ischemia, but recent trials have challenged this paradigm, highlighting the emerging role of vulnerable, non-flow-limiting coronary plaques, leading to a shift towards integrating plaque morphology with functional data into risk prediction models. Coronary computed tomography angiography (CCTA) represents a high-resolution, low-risk, and largely available non-invasive modality for the precise delineation of plaque composition, morphology, and inflammatory activity, further enhancing our ability to stratify high-risk plaque and predict adverse cardiovascular outcomes. Coronary artery calcium (CAC) scoring, derived from CCTA, has emerged as a promising tool for predicting future cardiovascular events in asymptomatic individuals, demonstrating incremental prognostic value beyond traditional cardiovascular risk factors in terms of myocardial infarction, stroke, and all-cause mortality. Additionally, CCTA-derived information on adverse plaque characteristics, geometric characteristics, and hemodynamic forces provides valuable insights into plaque vulnerability and seems promising in guiding revascularization strategies. Additionally, non-invasive assessments of epicardial and pericoronary adipose tissue (PCAT) further refine risk stratification, adding prognostic significance to coronary artery disease (CAD), correlating with plaque development, vulnerability, and rupture. Moreover, CT imaging not only aids in risk stratification but is now emerging as a screening tool able to monitor CAD progression and treatment efficacy over time. Thus, the integration of CAC scoring and PCAT evaluation into risk stratification algorithms, as well as the identification of high-risk plaque morphology and adverse geometric and hemodynamic characteristics, holds promising results for guiding personalized preventive interventions, helping physicians in identifying high-risk individuals earlier, tailoring lifestyle and pharmacological interventions, and improving clinical outcomes in their patients.

10.
Future Cardiol ; 20(1): 21-25, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38223918

RESUMO

Aim: Micra AV represents a leadless endocardial pacing system able to detect atrial contractions providing atrioventricular synchrony. A reduction of myocardial contractility may be detected in case of first-degree atrioventricular block (AVB). Materials & methods: In six patients with first-degree AVB (PQ interval ≥220 msec) was evaluated the left ventricle global longitudinal strain (LV GLS) by speckle tracking (ST) echocardiography during single-lead atrial sensing ventricular pacing (VDD) stimulation as compared with spontaneous rhythm (SR), 24-48 h after Micra AV implantation. Results: A statistically significant difference between the two modalities was observed (LV GLS during SR: -14.7% [interquartile range (IQR) 5.5], LV GLS during VDD pacing: -16.1% [IQR 5.2]; p value = 0.041). Conclusion: Our preliminary results suggest an improvement of myocardial contractility with VDD pacing as compared with SR.


What is this article about? The Micra AV is an electronic device placed in the heart chambers capable to supply the electrical activity of the heart. A reduction of cardiac contractility may be observed in patients with electrical disorders of the heart. What were the results? In six patients affected by electrical cardiac disorders, we observed an improvement of cardiac contractility using Micra AV as compared with the spontaneous electrical activity of the heart. What do the results of the study mean? The results of this study suggest that in patients carrying this electronic device should be preferred a specific modality of activation of the device as compared with the spontaneous electrical activity of the heart in order to improve the contractility of the cardiac walls.


Assuntos
Bloqueio Atrioventricular , Defeitos dos Septos Cardíacos , Marca-Passo Artificial , Humanos , Ventrículos do Coração/diagnóstico por imagem , Estimulação Cardíaca Artificial/métodos , Bloqueio Atrioventricular/terapia , Átrios do Coração/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA