1.
J Appl Clin Med Phys ; 12(2): 3330, 2011 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-21587175

RESUMO

The Brazilian Institute of Radiation Protection and Dosimetry (IRD/CNEN) carried out quality assurance regulatory audits in Brazilian radiotherapy facilities from 1995 to 2007. In this work, the set of data collected from 195 radiotherapy facilities that use high-energy photon beams are analyzed. They include results from audits in linear electron accelerators and/or Co-60 units. The inspectors of IRD/CNEN performed the dosimetry of high-energy radiotherapy photon beams according to the IAEA dosimetry protocols TRS 277 and TRS 398, and the values of measurements were compared to stated values. Other aspects of radiological protection were checked during on-site audits such as calibration certification of clinical dosimeters and portable monitors, existence and use of check source, use of barometer and thermometer, individual dose registry and training of staff. It was verified that no check source was available in 38% of the visited facilities; the training of personnel was not adequate in 9% of the facilities and the registry of accumulated individual doses was not being done in 6% of the facilities. Measurements of absorbed dose have indicated deviations in the range ± 3% for 67.6% of the cobalt-60 units and 79.6% of medical linear accelerators; 18.5% of Co-60 irradiators and 9.6% of linear accelerators presented deviations in the range 3% < δ ≤ 5%. Finally, 13.9% of Co-60 facilities and 10.8% of linear accelerator facilities presented dosimetry deviations above 5%. The effort in dosimetric quality control performed by IRD/CNEN audits has yielded positive changes that make radiation treatment facilities more reliable.


Assuntos
Radiometria/métodos , Radioterapia de Alta Energia/métodos , Brasil , Calibragem , Isótopos do Cobalto/química , Humanos , Aceleradores de Partículas , Controle de Qualidade , Radioterapia (Especialidade)/normas , Proteção Radiológica/métodos , Dosagem Radioterapêutica , Radioterapia de Alta Energia/normas , Segurança , Termômetros
2.
PLoS One ; 10(2): e0117548, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25679529

RESUMO

The combination of radiotherapy treatments and breast reconstruction, using temporary tissue expanders, generates several concerns due to the presence of a magnetic valve inside the radiation field. The objective of this work is to evaluate a radiotherapy treatment planning for a patient using a tissue expander. Isodose curve maps, obtained using radiochromic films, were compared to the ones calculated with two different dose calculation algorithms of the Eclipse radiotherapy Treatment Planning System (TPS), considering the presence or absence of the heterogeneity. The TPS calculation considering the presence of the heterogeneity shows changes around 5% in the isodose curves when they were compared with the calculation without heterogeneity correction. This calculation did not take in account the real density value of the heterogeneity. This limitation was quantified to be around 10% in comparison with the TPS calculation and experimental measurements using the radiochromic film. These results show that the magnetic valve should be taken in account in dose calculations of the TPS. With respect to the AAA and Pencil Beam Convolution algorithms, when the calculation is compared with the real distribution, AAA presents a distribution more similar to experimental dose distribution.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Dispositivos para Expansão de Tecidos , Implantes de Mama , Feminino , Humanos , Mamoplastia , Método de Monte Carlo , Imagens de Fantasmas
3.
PLoS One ; 5(5): e10466, 2010 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-20454675

RESUMO

In the radiotherapy treatment planning of a lesion located in the head region with small field radiation beams, the heterogeneity corrections play an important role. In this work, we investigated the influence of a bony heterogeneity on dose profile inside a soft tissue phantom containing a bony material. PDD curves were obtained by simulation using the Monte Carlo code EGSnrc and employing Eclipse(R) treatment planning system algorithms (Batho, Modified Batho, Equivalent TAR and Anisotropic Analytic Algorithm) for a 15 MV photon beam and field sizes of 2x2 and 10x10 cm(2). The Equivalent TAR method exhibited better agreement with Monte Carlo simulations for the 2x2 cm(2) field size. The magnitude of the effect on PDD due to the bony heterogeneity for 1x1, 2x2 and 10x10 cm(2) field sizes increases to 10, 5 and 3%, respectively.


Assuntos
Osso e Ossos/efeitos da radiação , Simulação por Computador , Método de Monte Carlo , Osso e Ossos/diagnóstico por imagem , Relação Dose-Resposta à Radiação , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X , Água