Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Eur J Clin Microbiol Infect Dis ; 37(8): 1573-1583, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29808350

RESUMO

Identification and antimicrobial susceptibility testing (AST) are critical steps in the management of bloodstream infections. Our objective was to evaluate the performance of the Accelerate Pheno™ System, CE v1.2 software, for identification and AST of Gram-negative pathogens from positive blood culture bottles. A total of 104 bottles positive for Gram-negative bacteria collected from inpatients throughout our institution were randomly selected after Gram staining. The time-to-identification and AST results, and the raw AST results obtained by the Accelerate Pheno™ system and routine techniques (MALDI-TOF MS and VITEK®2, EUCAST guidelines) were compared. Any discrepant AST result was tested by microdilution. The Pheno™ significantly improved turn-around times for identification (5.3 versus 23.7 h; p < 0.0001) and AST (10.7 versus 35.1 h; p < 0.0001). Complete agreement between the Accelerate Pheno™ system and the MALDI-TOF MS for identification was observed for 96.2% of samples; it was 99% (98/99) for monomicrobial samples versus 40% (3/5) for polymicrobial ones. The overall categorical agreement for AST was 93.7%; it was notably decreased for beta-lactams (cefepime 84.4%, piperacillin-tazobactam 86.5%, ceftazidime 87.6%) or Pseudomonas aeruginosa (71.9%; with cefepime 33.3%, piperacillin-tazobactam 77.8%, ceftazidime 0%). Analysis of discrepant results found impaired performance of the Accelerate Pheno™ system for beta-lactams (except cefepime) in Enterobacteriales (six very major errors) and poor performance in P. aeruginosa. The Accelerate Pheno™ system significantly improved the turn-around times for bloodstream infection diagnosis. Nonetheless, improvements in the analysis of polymicrobial samples and in AST algorithms, notably beta-lactam testing in both P. aeruginosa and Enterobacteriales, are required for implementation in routine workflow.


Assuntos
Antibacterianos/farmacologia , Bacteriemia/diagnóstico , Bacteriemia/microbiologia , Técnicas de Tipagem Bacteriana , Bactérias Gram-Negativas/efeitos dos fármacos , Infecções por Bactérias Gram-Negativas/diagnóstico , Infecções por Bactérias Gram-Negativas/microbiologia , Testes de Sensibilidade Microbiana , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , Bacteriemia/tratamento farmacológico , Criança , Pré-Escolar , Bactérias Gram-Negativas/classificação , Bactérias Gram-Negativas/isolamento & purificação , Infecções por Bactérias Gram-Negativas/tratamento farmacológico , Humanos , Lactente , Recém-Nascido , Testes de Sensibilidade Microbiana/métodos , Pessoa de Meia-Idade , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Fatores de Tempo , Adulto Jovem
2.
Anal Biochem ; 435(2): 153-8, 2013 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-23333226

RESUMO

The development of a method for the quantification of Legionella pneumophila genomic deoxyribonucleic acid is considered. The method is based on the quantification by inductively coupled plasma mass spectrometry (ICP-MS) of the mass fraction of phosphorus, stoichiometrically presented in the DNA molecules. Through the DNA sequencing data, it was possible to convert the ICP-MS analysis results into DNA genome units. L. pneumophila DNA samples were analyzed using ICP-sector field MS and ICP-quadrupole MS with a collision/reaction cell. Spectrophotometric measurements of the absorbance at 260nm and real-time PCR techniques were used to independently confirm the ICP-MS results. The comparison of the methods showed that the ICP-MS method provides better accuracy with respect to currently applied analytical techniques such as UV spectrophotometry, fluorescent dye methods, and real-time PCR. Moreover, with the use of calibration standards whose values are traceable to the International System of Units and the possibility of evaluating the contribution to the overall uncertainty of each step of the measurement procedure, the method enables long-term comparability of the measurement results. These advantages make the ICP-MS method suitable for nucleic acid investigation, from nucleotides to genomic DNA, as well as for the certification of the reference materials containing nucleic acids.


Assuntos
DNA Bacteriano/análise , Genoma Bacteriano , Legionella pneumophila/genética , Espectrometria de Massas , Calibragem , DNA Bacteriano/normas , Espectrometria de Massas/normas , Reação em Cadeia da Polimerase em Tempo Real , Espectrofotometria Ultravioleta
3.
Ann Biol Clin (Paris) ; 80(2): 190-198, 2022 Mar 01.
Artigo em Francês | MEDLINE | ID: mdl-35766069

RESUMO

INTRODUCTION: Le niveau d'expression des molécules HLA-DR à la surface des monocytes (mHLA-DR) est un marqueur diagnostique utilisé pour évaluer l'immunité des patients en réanimation (choc septique, polytraumatisés, brulures, greffe et plus récemment Covid-19). Il est également utilisé comme un outil de stratification dans les essais cliniques utilisant des thérapies immunostimulantes chez ces patients. L'objectif de cette étude était d'évaluer les performances analytiques d'une méthode de cytométrie en flux pour mesurer mHLA-DR afin de répondre aux exigences de la norme NF EN ISO 15189 dans le cadre de l'accréditation des laboratoires de biologie médicale. Matériels et méthodes. L'évaluation (performances de la technique, étendue de la mesure, comparaison de méthode) a été menée en suivant le SH GTA 04, guide recommandé par le Comité français d'accréditation (COFRAC). En complément, certaines conditions pré analytiques ont été ré-évaluées. Résultats. L'ensemble des coefficients de variation évaluant les performances étaient inférieurs à 10 % (répétabilité, reproductibilité, variabilité interopérateur). Les limites de quantification et de linéarité étaient adaptées à l'utilisation clinique du paramètre. Les résultats étaient identiques quel que soit le type et le fournisseur de cytomètre en flux. Les contraintes de conservation pré-analytiques des échantillons ont été confirmées. CONCLUSION: Les résultats étaient conformes aux exigences de qualité recommandées par le COFRAC. Ils permettent l'accréditation de la mesure de mHLA-DR par cytométrie en flux et son utilisation en soins courants.


Assuntos
COVID-19 , Antígenos HLA-DR , Monócitos , Citometria de Fluxo , Antígenos HLA-DR/biossíntese , Antígenos HLA-DR/imunologia , Humanos , Monócitos/imunologia , Monócitos/metabolismo
4.
J Microbiol Methods ; 157: 50-53, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30578889

RESUMO

A value was assigned in 2009 to the Legionella DNA Certified Reference Material, and the stability study conducted using quantitative PCR found a low level of degradation. Herein, the Digital Droplet PCR method for Legionella DNA was qualified and used to provide absolute quantification of the CRM.


Assuntos
Fragmentação do DNA , DNA Bacteriano/normas , Legionella/genética , DNA Bacteriano/genética , Reação em Cadeia da Polimerase em Tempo Real , Padrões de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA