Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(10)2023 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-37430650

RESUMO

This study aims to analyze the asymmetry between both eyes of the same patient for the early diagnosis of glaucoma. Two imaging modalities, retinal fundus images and optical coherence tomographies (OCTs), have been considered in order to compare their different capabilities for glaucoma detection. From retinal fundus images, the difference between cup/disc ratio and the width of the optic rim has been extracted. Analogously, the thickness of the retinal nerve fiber layer has been measured in spectral-domain optical coherence tomographies. These measurements have been considered as asymmetry characteristics between eyes in the modeling of decision trees and support vector machines for the classification of healthy and glaucoma patients. The main contribution of this work is indeed the use of different classification models with both imaging modalities to jointly exploit the strengths of each of these modalities for the same diagnostic purpose based on the asymmetry characteristics between the eyes of the patient. The results show that the optimized classification models provide better performance with OCT asymmetry features between both eyes (sensitivity 80.9%, specificity 88.2%, precision 66.7%, accuracy 86.5%) than with those extracted from retinographies, although a linear relationship has been found between certain asymmetry features extracted from both imaging modalities. Therefore, the resulting performance of the models based on asymmetry features proves their ability to differentiate healthy from glaucoma patients using those metrics. Models trained from fundus characteristics are a useful option as a glaucoma screening method in the healthy population, although with lower performance than those trained from the thickness of the peripapillary retinal nerve fiber layer. In both imaging modalities, the asymmetry of morphological characteristics can be used as a glaucoma indicator, as detailed in this work.


Assuntos
Glaucoma , Humanos , Glaucoma/diagnóstico por imagem , Tomografia de Coerência Óptica , Retina/diagnóstico por imagem , Diagnóstico Precoce , Fundo de Olho
2.
Sensors (Basel) ; 22(13)2022 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-35808338

RESUMO

Purpose: The aim of this study was to analyze the relevance of asymmetry features between both eyes of the same patient for glaucoma screening using optical coherence tomography. Methods: Spectral-domain optical coherence tomography was used to estimate the thickness of the peripapillary retinal nerve fiber layer in both eyes of the patients in the study. These measurements were collected in a dataset from healthy and glaucoma patients. Several metrics for asymmetry in the retinal nerve fiber layer thickness between the two eyes were then proposed. These metrics were evaluated using the dataset by performing a statistical analysis to assess their significance as relevant features in the diagnosis of glaucoma. Finally, the usefulness of these asymmetry features was demonstrated by designing supervised machine learning models that can be used for the early diagnosis of glaucoma. Results: Machine learning models were designed and optimized, specifically decision trees, based on the values of proposed asymmetry metrics. The use of these models on the dataset provided good classification of the patients (accuracy 88%, sensitivity 70%, specificity 93% and precision 75%). Conclusions: The obtained machine learning models based on retinal nerve fiber layer asymmetry are simple but effective methods which offer a good trade-off in classification of patients and simplicity. The fast binary classification relies on a few asymmetry values of the retinal nerve fiber layer thickness, allowing their use in the daily clinical practice for glaucoma screening.


Assuntos
Glaucoma , Tomografia de Coerência Óptica , Árvores de Decisões , Glaucoma/diagnóstico por imagem , Humanos , Fibras Nervosas , Células Ganglionares da Retina , Tomografia de Coerência Óptica/métodos
3.
Sensors (Basel) ; 21(5)2021 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-33806324

RESUMO

Running retraining programs focused on concurrent feedback of acceleration impacts have been demonstrated to be a good strategy to reduce running-related injuries (RRI), as well as to improve running economy and reduce acceleration impacts and injury running incidence. Traditionally, impacts have been registered by mean of accelerometers attached directly to the athletes, which is inaccessible to the entire population, because it requires laboratory conditions. This study investigated the validity and reliability of a new device integrated directly into the treadmill, compared to a traditional acceleration impact system. Thirty healthy athletes with no history of RRI were tested on two separate days over the instrumented treadmill (AccTrea) and simultaneously with an acceleration impact system attached to the participant (AccAthl). AccTrea was demonstrated to be a valid and reliable tool for measuring spatio-temporal parameters like step length (validity intraclass correlation coefficient (ICC) = 0.94; reliability ICC = 0.92), step time (validity ICC = 0.95; reliability ICC = 0.96), and step frequency (validity ICC = 0.95; reliability ICC = 0.96) during running. Peak acceleration impact variables showed a high reliability for the left (reliability ICC = 0.88) and right leg (reliability ICC = 0.85), and peak impact asymmetry showed a modest validity (ICC = 0.55). These results indicated that the AccTrea system is a valid and reliable way to assess spatio-temporal variables, and a reliable tool for measuring acceleration impacts during running.


Assuntos
Acelerometria , Corrida , Aceleração , Teste de Esforço , Marcha , Humanos , Reprodutibilidade dos Testes
4.
Sensors (Basel) ; 21(23)2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34884031

RESUMO

Glaucoma is a neurodegenerative disease process that leads to progressive damage of the optic nerve to produce visual impairment and blindness. Spectral-domain OCT technology enables peripapillary circular scans of the retina and the measurement of the thickness of the retinal nerve fiber layer (RNFL) for the assessment of the disease status or progression in glaucoma patients. This paper describes a new approach to segment and measure the retinal nerve fiber layer in peripapillary OCT images. The proposed method consists of two stages. In the first one, morphological operators robustly detect the coarse location of the layer boundaries, despite the speckle noise and diverse artifacts in the OCT image. In the second stage, deformable models are initialized with the results of the previous stage to perform a fine segmentation of the boundaries, providing an accurate measurement of the entire RNFL. The results of the RNFL segmentation were qualitatively assessed by ophthalmologists, and the measurements of the thickness of the RNFL were quantitatively compared with those provided by the OCT inbuilt software as well as the state-of-the-art methods.


Assuntos
Doenças Neurodegenerativas , Tomografia de Coerência Óptica , Humanos , Fibras Nervosas , Retina/diagnóstico por imagem , Células Ganglionares da Retina
5.
Artigo em Inglês | MEDLINE | ID: mdl-34065387

RESUMO

An increase in the popularity of running can be seen over the last decades, with a large number of injuries on it. Most of the running injuries are related to impact accelerations and are due to overuse. In order to reduce the risk of injury or to improve performance and health new treadmill designs have been created, as it can be the curved non-motorized treadmill. The aim of this study was to analyse impact accelerations, spatio-temporal parameters and perceptual differences while running on curved non-motorized treadmill (cNMT) compared to motorized treadmill (MT) at different speeds. Therefore, 27 recreational runners completed two tests consisting of 10 min warm-up and three bouts of 8 min running at 2.77 m/s, 3.33 m/s and self-selected speed on cNMT and MT, previously randomised. Although the surface did not influence spatio-temporal parameters, a reduction in impact accelerations, head acceleration rate (mean effect size [ES] = 0.86), tibia peak (mean ES = 0.45) and tibia magnitude (mean ES = 0.55), was observed while running on cNMT in comparison with running on MT. Moreover, higher heart rate (HR) (mean ES = 0.51) and rating of perceived effort (RPE) (mean ES = 0.34) were found while running on cNMT. These findings demonstrated that higher intensity training and lower impact accelerations are experimented on cNMT, what can be used by trainers and athletes while planning training sessions.


Assuntos
Teste de Esforço , Exercício de Aquecimento , Aceleração , Atletas , Frequência Cardíaca , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA