Artigo em Inglês | MEDLINE | ID: mdl-39001763

RESUMO

BACKGROUND: Dark-blood late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) has better correlation with bipolar voltage (BiV) to define ablation scar in the left atrium (LA) compared to conventional bright-blood LGE CMR. OBJECTIVES: This study sought to determine the optimal signal intensity threshold of dark-blood LGE CMR to identify LA ablation scar. METHODS: In 54 patients scheduled for atrial fibrillation ablation, image intensity ratios (IIRs) were derived from preprocedural dark-blood LGE CMR. In 26 patients without previous ablation, the upper limit of normal was derived from the 95th and 98th percentiles of pooled IIR values. In 28 patients with previous atrial fibrillation ablation, BiV was compared with the corresponding IIR. Receiver-operating characteristics analyses were employed to determine the optimal IIR threshold (ie, the point with the smallest distance to the upper left corner of the receiver-operating characteristics) for LA ablation scar (BiV ≤0.15 mV). RESULTS: Upper limit of normal corresponded to IIR values 1.16 and 1.21, yielding low sensitivities of 0.32 and 0.09 to detect LA ablation scar. Receiver-operating characteristics analysis of IIR and BiV comparison achieved a median area under the curve of 0.77. Median optimal IIR threshold for LA ablation scar was 1.09, with an average sensitivity of 0.73, specificity of 0.75, and accuracy of 0.71. Median IIR thresholds of 1.00 and 1.10 corresponded to 80% sensitivity and 80% specificity, respectively. There was considerable interpatient variability: optimal IIR thresholds per patient ranged from 1.01 to 1.22. CONCLUSIONS: The optimal IIR threshold to identify LA ablation scar by dark-blood LGE CMR is 1.09. Because of interpatient variability, the investigators recommend using a lower (1.00) and upper (1.10) threshold to prevent over- or underestimation of ablation scar.

2.
Eur Heart J Case Rep ; 6(1): ytab530, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35106444

RESUMO

BACKGROUND: Surgical epicardial atrial fibrillation (AF) ablation can be performed as a stand-alone (thoracoscopic) procedure or concomitant to other cardiac surgery. In hybrid AF ablation thoracoscopic surgical epicardial ablation is combined with a percutaneous endocardial ablation. The Medtronic Gemini-S clamp is a surgical tool that uses irrigated bipolar biparietal radiofrequency (RF) energy applied with two clamp lesions that overlap to create one epicardial box lesion including the posterior left atrial wall and the pulmonary veins. CASE SUMMARY: We describe three patients with therapy-refractory persistent AF and different stages of atrial remodelling in whom the Medtronic Cardioblate Gemini-S Irrigated RF Surgical Ablation System was used for hybrid AF ablation. Acute endocardial validation at the end of the hybrid ablation revealed a complete box lesion in all three cases. At 2-year follow-up, two out of three patients had recurrence of atrial arrhythmias. Invasive electro-anatomical mapping confirmed the persistence of the box lesion, and the mechanism of arrhythmia recurrence in both patients was unrelated to posterior left atrium or the pulmonary veins. The third patient has been without arrhythmia symptoms since the ablation procedure. A three-dimensional late gadolinium enhancement magnetic resonance imaging illustrates the ablation scar non-invasively in two cases. DISCUSSION: Thoracoscopic biparietal RF AF ablation with the Medtronic Cardioblate Gemini-S Irrigated RF Surgical Ablation System results in permanent transmural scar formation, irrespective of the stage of atrial remodelling, as shown in this small population by means of multimodality scar evaluation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA