1.
Am J Cardiol ; 80(7): 852-8, 1997 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-9381997

RESUMO

Prognostic studies after acute myocardial infarction (AMI) have mainly been performed in the prethrombolytic era. Despite the fact that modern management of AMI has reduced mortality rates, the occurrence of malignant ventricular arrhythmias in the late phase of AMI remains an important issue. We prospectively studied 244 consecutive patients (97 treated with thrombolytics) who survived a first AMI. All patients underwent time domain signal-averaged electrocardiography (vector magnitude: measurements of total QRS duration, terminal low [<40 microV] amplitude signal duration, and root-mean-square voltage of the last 40 ms of the QRS complex), Holter electrocardiographic monitoring, and cardiac catheterization. Late life-threatening ventricular arrhythmias were recorded. Eighteen arrhythmic events occurred during a mean follow-up period of 57 +/- 18 months. Three independent factors were associated with a higher risk of arrhythmic events: (1) left ventricular ejection fraction (odds ratio 1.9/0.10 decrease), (2) terminal low-amplitude signal duration (odds ratio 1.5/5 ms increase), and (3) absence of thrombolytic therapy (odds ratio 3.9). Low-amplitude signal duration sensitivity for sudden cardiac death was low (30%). Left ventricular ejection fraction had the highest positive predictive value for sudden cardiac death (10%). Thus, thrombolysis decreases both the incidence of ventricular tachycardia and sudden cardiac death with a higher reopening rate of the infarct-related vessel. Signal averaging predicts the occurrence of ventricular tachycardia and an impaired left ventricular ejection fraction predicts the occurrence of sudden cardiac death.


Assuntos
Arritmias Cardíacas/etiologia , Infarto do Miocárdio/complicações , Terapia Trombolítica , Angiografia Coronária , Morte Súbita Cardíaca/etiologia , Eletrocardiografia/métodos , Eletrocardiografia Ambulatorial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/tratamento farmacológico , Infarto do Miocárdio/fisiopatologia , Prognóstico , Estudos Prospectivos , Processamento de Sinais Assistido por Computador , Volume Sistólico
2.
J Interv Card Electrophysiol ; 1(3): 227-33, 1997 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-9869976

RESUMO

The objective of this study was to assess the effects of radiofrequency energy application on implanted pacemaker functions. Radiofrequency (RF) catheter ablation may cause pacemaker dysfunction due to electromagnetic interferences. The effects of RF on pacemaker behavior were studied in a series of 38 pacemakers, implanted 18 +/- 26 months prior to a RF procedure using either a right ventricular approach (AV node ablation, n = 35) or a left ventricular approach (left concealed accessory pathway ablation, n = 1; VT ablation, n = 2). The 38 patients (mean age 65 +/- 9 years) included 20 men and 18 women. Before energy applications, the 23 different pacemaker models were programmed to the VVI mode at the lowest available rate. The continuous surface ECG was recorded throughout the procedure. Thorough testing of the devices was performed before and after each RF delivery. Unusual pacemaker responses occurred in 20 of the 38 cases studied (53%). The impact of RF delivery was unpredictable, and variable dysfunctions were observed at different times for a given patient or could vary for a given model. Unusual pacemaker responses included pacemaker inhibition (n = 8), untoggled backup mode (n = 3), electromagnetic interference noise mode (n = 3), temporary RF-induced pacemaker tachycardia (n = 2), erratic behavior (n = 1), oversensing of RF onset and offset (n = 8), and transient loss of ventricular capture, (n = 1). Postablation, most devices automatically toggled back to full functionality. The three devices in the untoggled backup mode had to be reprogrammed to obtain normal operations. At the end of the procedure, pacing thresholds remained unchanged in all but one patient, in whom the increase in ventricular threshold was due to a nicked lead. In conclusion, implanted pacemakers frequently exhibit transient, unpredictable responses to RF energy application. Although all pacemaker functions were restored postablation, some devices had to be reset manually. The anomalies observed during the RF application argue for the simultaneous use of an external pacemaker in pacing-dependent patients.


Assuntos
Estimulação Cardíaca Artificial/efeitos adversos , Ablação por Cateter/efeitos adversos , Adulto , Idoso , Artefatos , Eletrocardiografia , Falha de Equipamento , Feminino , Humanos , Complicações Intraoperatórias/etiologia , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória , Período Pós-Operatório , Taquicardia/etiologia , Fatores de Tempo